ML020650421

From kanterella
Jump to navigation Jump to search
Tabulation of Personnel Radiation Exposure for 2001 by Work and Job Function
ML020650421
Person / Time
Site: Farley  Southern Nuclear icon.png
Issue date: 03/04/2002
From: Dennis Morey
Southern Nuclear Operating Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NEL-02-0054
Download: ML020650421 (4)


Text

Dave Morey Southern Nuclear Vice President Operating Company, Inc.

Farley Project Post Office Box 1295 Birmingham, Alabama 35201 Tel 205,992.5131 SOUTHERN hk COMPANY Energy to Serve Your World"'

March 4, 2002 NEL-02-0054 Docket Nos.: 50-348 50-364 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 - 0001 Joseph M. Farley Nuclear Plant Tabulation of Personnel Radiation Exposure for 2001 by Work and Job Function Ladies and Gentlemen:

In accordance with Section 5.6.1. of the Joseph M. Farley Nuclear Plant Units 1 and 2 Technical Specifications, a tabulation of personnel radiation dose greater than 100 mrem by work and job functions during 2001 is herewith submitted. The tabulation combines the data from both Farley units. The data provided represents the total 2001 site dose for these personnel and is not an estimate.

There are no new commitments in this submittal. If further clarification is necessary, please advise.

Respectfully submitted, Dave Morey RIHM/kw annual rpt rad dist.doc Attachment (a

Page 2 U.S. Nuclear Regulatory Commission cc:

Southern Nuclear Operating Company Mr. D. E. Grissette, General Manager - Farley U. S. Nuclear Regulatory Commission, Washington, D.C.

Mr. F. Rinaldi, NRR Project Manager U. S. Nuclear Regulatory Commission, Region II Mr. L. A. Reyes, Regional Administrator Mr. T. P. Johnson, FNP Senior Resident Inspector

ATTACHMENT Tabulation Of Personnel Radiation Exposure At The Joseph M. Farley Nuclear Plant For 2001 By Work And Job Function

ATTACHMENT TABULATION OF PERSONNEL RADIATION EXPOSURE AT THE JOSEPH M. FARLEY NUCLEAR PLANT FOR 2001 BY WORK AND JOB FUNCTION Number of Personnel > 100 mrem Station Utility Contract Total Man-Rem*

Station Utility Contract Reactor Operation & Surveillance Maintenance Personnel 0

0 3

0.152 0.004 2.007 Operating Personnel 56 0

1 13.278 0.003 0.228 Health Physics Personnel 16 1

30 4.718 0.248 7.073 Supervisory Personnel 0

1 0

0.513 0.261 0.228 Engineering Personnel 1

0 1

0.834 0.077 0.552 Routine Maintenance Maintenance Personnel 2

0 5

4.206 0.033 1.586 Operating Personnel 11 0

0 2.721 0.000 0.000 Health Physics Personnel 0

0 0

0.110 0.000 0.003 Supervisory Personnel 0

0 0

0.019 0.000 0.001 Engineering Personnel 0

0 0

0.040 0.000 0.000 Inservice Inspection Maintenance Personnel 0

0 30 0.044 0.000 8.101 Operating Personnel 2

0 0

0.790 0.000 0.003 Health Physics Personnel 1

0 2

0.948 0.000 0.633 Supervisory Personnel 0

1 0

0.000 0.142 0.002 Engineering Personnel 3

1 17 0.880 0.195 5.062 Special Maintenance Maintenance Personnel 106 0

552 26.189 0.151 159.964 Operating Personnel 28 0

7 7.256 0.000 2.239 Health Physics Personnel 17 0

26 3.308 0.015 7.050 Supervisory Personnel 3

0 22 0.561 0.162 6.492 Engineering Personnel 1

0 12 0.311 0.059 5.761 Waste Processing Maintenance Personnel 8

0 0

2.331 0.001 0.086 Operating Personnel 2

0 1

1.485 0.000 0.313 Health Physics Personnel 5

0 1

3.305 0.000 0.382 Supervisory Personnel 0

0 0

0.021 0.001 0.000 Engineering Personnel 0

0 0

0.000 0.000 0.000 Refueling Maintenance Personnel 69 0

0 29.375 0.015 0.086 Operating Personnel 4

0 13 1.691 0.000 3.714 Health Physics Personnel 2

0 4

0.784 0.030 0.995 Supervisory Personnel 0

0 1

0.234 0.004 0.185 Engineering Personnel 0

0 0

0.077 0.067 0.114 Totals Maintenance Personnel 185 0

590 62.297 0.204 171.830 Operating Personnel 103 0

22 27.221 0.003 6.497 Health Physics Personnel 41 1

63 13.173 0.293 16.136 Supervisory Personnel 3

2 23 1.348 0.570 6.908 Engineering Personnel 5

1 30 2.142 0.398 11.489 Grand Total 337 4

728 106.181 1.468 212.860 NOTES

"*1. The total radiation exposure of the above personnel is 320.509 which constitutes 100% of site exposure for the year.

2. Individual workers may be included in more than one category based upon job function.
3. Special Maintenance includes steam generator replacement, other plant design modifications and various other maintenance activities not normally considered routine in nature.

ANN_RG116_REP