ML020650008

From kanterella
Jump to navigation Jump to search
January 2002 Monthly Operating Report for Prairie Island Nuclear Generating Plant, Units 1 and 2
ML020650008
Person / Time
Site: Prairie Island  Xcel Energy icon.png
Issue date: 02/11/2002
From: Nazar M
Nuclear Management Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML020650008 (7)


Text

Committed to Nuclear Excellence '___________________________

-1 Nuclear Management Company, LLC Prairie Island Nuclear Generating Plant 1717 Wakonade Dr. East

50-282 License Nos. DPR-42 50-306 DPR-60 Monthly Operating Report January, 2002 Attached is the Monthly Operating Report for January, 2002 for the Prairie Island Nuclear Generating Plant.

YK

-1J4 Al Mano Nazar Site Vice Pre d nt Prairie Island clear Generating Plant c:

Regional Administrator-Ill, NRC NRR Project Manager, NRC NRC Resident Inspector State of Minnesota - James Bernstein Attachment

NRC MONTHLY REPORT PRINTED 2/5/2002 Page 1 DOCKET NO. 50-282 UNIT PRAIRIE ISLAND NO. 1 DATE 2/5/2002 COMPLETED BY DALE DUGSTAD PHONE 651-388-1121-4376 NARRATIVE

SUMMARY

OF OPERATING EXPERIENCE MONTH: JANUARY 2002 During the month of January, Unit 1 was base loaded. There were no shutdowns and only one power reduction.

On the 19th, the Unit reduced power to conduct a turbine valve test.

There are no other items to report.

CURRENT CONTINUOUS OPERATING RUN OF 142 DAYS

NRC MONTHLY REPORT PRINTED 2/5/2002 Page 2 DOCKET NO. 50-282 UNIT PRAIRIE ISLAND NO. I DATE 2/5/2002 COMPLETED BY DALE DUGSTAD PHONE 651-388-1121-4376 OPERATING DATA REPORT OPERATING STATUS

1. UNIT NAME:

PRAIRIE ISLAND NO. 1

2. REPORTING PERIOD:

JANUARY 2002

3. LICENSED THERMAL POWER (MWT): 1650
4. NAMEPLATE RATING (GROSS MWE):

593

5. DESIGN ELECTRICAL RATING (NET MWE): 536
6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE):

554

7. MAXIMUM DEPENDABLE CAPACITY (NET MWE):

522

8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 - 7) SINCE LAST REPORT, GIVE REASON:

NONE

9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE):

NONE

10. REASONS FOR RESTRICTIONS, IF ANY:

NONE THIS MONTH YR-TO-DATE CUMULATIVE

11. HOURS IN REPORTING PERIOD 744 744 246576
12. NUMBER OF HOURS REACTOR CRITICAL 744.0 744.0 212676.1
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 5571.1
14. HOURS GENERATOR ON-LINE 744.0 744.0 210718.6
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
16. GROSS THERMAL ENERGY GENERATED (MWH) 1222440 1222440 335991696
17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 426500 426500 111632750
18. NET ELECTRICAL ENERGY GENERATED (MWH) 406257 406257 105096764
19. UNIT SERVICE FACTOR 100.0 100.0 85.5
20. UNIT AVAILABILITY FACTOR 100.0 100.0 85.5
21. UNIT CAPACITY FACTOR ( MDC NET) 104.6 104.6 84.0
22. UNIT CAPACITY FACTOR ( DER NET) 101.9 101.9 80.3
23. UNIT FORCED OUTAGE RATE 0.0 0.0 4.7
24. FORCED OUTAGE HOURS 0.0 0.0 10462.7

NRC MONTHLY REPORT PRINTED 2/5/2002 Page 3 DOCKET NO. 50-282 UNIT PRAIRIE ISLAND NO. 1 DATE 2/5/2002 COMPLETED BY DALE DUGSTAD PHONE 651-388-1121-4376 UNIT SHUTDOWNS AND POWER REDUCTIONS MONTH: JANUARY 2002 UNIT TYPE 1

S Turbine valve test.

HOURS REASON METHOD LER NUMBER SYSTEM COMPONENT 0

B 5

N/A N/A N/A TYPE F-FORCED S-SCHEDULED REASON A-EQUIPMENT FAILURE B-MAINTENANCE OR TEST C-REFUELING D-REGULATORY RESTRICTION E-OPERATOR TRAINING AND LICENSE EXAMINATION F-ADMINISTRATIVE G-OPERATIONAL ERROR METHOD 1-MANUAL 2-MANUAL TRIP 3-AUTO TRIP 4-CONTINUED 5-REDUCED LOAD 9-OTHER SYSTEM CODE DRAFT IEEE STD 800-1984(P805-D5)

COMPONENT CODE IEEE STD 803A-1983 H-OTHER DATE 1/19/2002 NOTES:

NRC MONTHLY REPORT PRINTED 2/5/2002 Page 4 DOCKET NO. 50-306 UNIT PRAIRIE ISLAND NO. 2 DATE 2/5/2002 COMPLETED BY DALE DUGSTAD PHONE 651-388-1121-4376 NARRATIVE

SUMMARY

OF OPERATING EXPERIENCE MONTH: JANUARY 2002 During the month of January, Unit 2 was base loaded. There were no shutdowns.

The Unit started coastdown operations on the 18th.

The refueling outage is scheduled to start on February 2, 2002.

There are no other items to report.

CURRENT CONTINUOUS OPERATING RUN OF 89 DAYS

NRC MONTHLY REPORT PRINTED 2/5/2002 Page 5 DOCKET NO. 50-306 UNIT PRAIRIE ISLAND NO. 2 DATE 2/5/2002 COMPLETED BY DALE DUGSTAD PHONE 651-388-1121-4376 OPERATING DATA REPORT OPERATING STATUS

1. UNIT NAME:

PRAIRIE ISLAND NO. 2

2. REPORTING PERIOD:

JANUARY 2002

3. LICENSED THERMAL POWER (MWT):

1650

4. NAMEPLATE RATING (GROSS MWE):

593

5. DESIGN ELECTRICAL RATING (NET MWE): 536
6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE):

554

7. MAXIMUM DEPENDABLE CAPACITY (NET MWE):

522

8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 - 7) SINCE LAST REPORT, GIVE REASON:

NONE

9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE):

NONE

10. REASONS FOR RESTRICTIONS, IF ANY:

NONE THIS MONTH YR-TO-DATE CUMULATIVE

11. HOURS IN REPORTING PERIOD 744 744 237694
12. NUMBER OF HOURS REACTOR CRITICAL 744.0 744.0 210742.1
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 1516.1
14. HOURS GENERATOR ON-LINE 744.0 744.0 209072.6
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
16. GROSS THERMAL ENERGY GENERATED (MWH) 1195623 1195623 334392421
17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 416430 416430 110226810
18. NET ELECTRICAL ENERGY GENERATED (MWH) 396675 396675 104230545
19. UNIT SERVICE FACTOR 100.0 100.0 88.0
20. UNIT AVAILABILITY FACTOR 100.0 100.0 88.0
21. UNIT CAPACITY FACTOR (MDC NET) 102.1 102.1 86.9
22. UNIT CAPACITY FACTOR ( DER NET) 99.5 99.5 82.6
23. UNIT FORCED OUTAGE RATE 0.0 0.0 3.0
24. FORCED OUTAGE HOURS 0.0 0.0 6390.7

NRC MONTHLY REPORT PRINTED 2/5/2002 Page 6 DOCKET NO. 50-306 UNIT PRAIRIE ISLAND NO. 2 DATE 2/5/2002 COMPLETED BY DALE DUGSTAD PHONE 651-388-1121-4376 UNIT SHUTDOWNS AND POWER REDUCTIONS MONTH: JANUARY 2002 DATE UNIT TYPE HOURS REASON METHOD LER NUMBER SYSTEM 1/18/2002 2

S 0

C 5

N/A N/A NOTES:

Coastdown operation. Refueling will start in February.

COMPONENT N/A TYPE F-FORCED S-SCHEDULED REASON A-EQUIPMENT FAILURE B-MAINTENANCE OR TEST C-REFUELING D-REGULATORY RESTRICTION E-OPERATOR TRAINING AND LICENSE EXAMINATION F-ADMINISTRATIVE G-OPERATIONAL ERROR H-OTHER METHOD 1-MANUAL 2-MANUAL TRIP 3-AUTO TRIP SYSTEM CODE DRAFT IEEE STD 800-1984(P805-D5) 4-CONTINUED 5-REDUCED LOAD COMPONENT CODE 9-OTHER IEEE STD 803A-1983