Indiana Michigan Power Company 500 Circle Drive Buchanan, MI 49107 1373 INDIANA MICHIGAN POWER February 19, 2002 AEP:NRC:2455 Docket No:

50-316 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Mail Stop O-P 1-17 Washington, DC 20555-0001 Donald C. Cook Nuclear Plant Unit 2 STEAM GENERATOR TUBE INSERVICE INSPECTION REPORT Indiana Michigan Power Company, the licensee for Donald C. Cook Nuclear Plant (CNP) Unit 2, is submitting this letter in accordance with Technical Specification 4.4.5.5.a, to notify the Nuclear Regulatory Commission that, based upon eddy current inspection results during CNP's Unit 2 Cycle 13 steam generator inspection, no tubes required repair (plugging) in steam generators 21, 22, 23, or 24.

There are no new commitments in this submittal.

Should you have any questions, please contact Mr. Gordon P. Arent, Manager of Regulatory Affairs, at (616) 697-5553.

Sincerely, S. A. Greenlee Director of Nuclear Technical Services

/jen c:

K. D. Curry J. E. Dyer MDEQ-DW&RPD NRC Resident Inspector R. Whale