RPS Instrumentation 3.3.1.1 Table 3.3.1.1-1 (page 3 of 3)

Reactor Protection System Instrumentation APPLICABLE CONDITIONS MODES OR REQUIRED REFERENCED OTHER CHANNELS FROM SPECIFIED PER TRIP REQUIRED SURVEILLANCE ALLOWABLE FJNCTION CONDITIONS SYSTEM ACTION D.1 REQUIREMENTS VALUE

7.

Scram Discharge Volume Water Level-High

a.

Thermal Switch (for Unit I only through cycle 17)

Float Switch

b.

Differential Pressure Switch 1,2 5f.)

1.2 2

2 2

2

8.

Turbine Stop Valve-Closure

9.

Turbine Control Valve Fast Closure, Trip Oil Pressure-Low

10.

Turbine Condenser Vacuum-Low

11.

Reactor Mode Switch Shutdown Position G

SR SR SR SR H

SR SR SR SR G

SR SR SR SR H

SR SR SR SR 3.3.1.1.5 3.3.1.1.10 3.3.1.1.16 3.3.1.1.17 3.3.1.1.5 3.3.1.1.10 3.3.1.1.16 3.3.1.1.17 3.3.1.1.5 3.3.1.1.10 3.3.1.1.16 3.3.1.1.17 3.3.1.1.5 3.3.1.1.10 3.3.1.1.16 3.3.1.1.17 SR 3.3.1.1.5 S45% RTP (Unit 1)

38.5% RTP (Unit 2) z 45% RTP (Unit 1) a 38.5% RTP (Unit 2)

SR SR SR SR SR E

SR SR SR SR SR SR 2

1.2 SR SR SR SR SR 3.3.1.1.10 3.3.1.1.13 3.3.1.1.16 3.3.1.1.17 3.3.1.1.18 3.3.1.1.5 3.3.1.1.10 3.3.1.1.13 3.3.1.1.16 3.3.1.1.17 3.3.1.1.18 3.3.1.1.5 3.3.1.1.10 3.3.1.1.12 3.3.1.1.17 3.3.1.1.18 G

SR 3.3.1.1.15 SR 3.3.1.1.17 SR 3.3.1.1.15 SR 3.3.1.1.17

12.

Manual Scram 1,2 1

1 G

SR 3.3.1.1.8 SR 3.3.1.1.17 H

SR 3.3.1.1.8 SR 3.3.1.1.17

, 38.9 gallons S38.9 gallons

32.3 gallons s 32.3 gallons
9.7% closed z 475 psig Z 21.8 inches Hg vacuum (Unit 1) a 21.6 inches Hg vacuum (Unit 2)

NA NA NA NA Amendment No. 203/199 (a)

With any control rod withdrawn from a core cell containing one or more fuel assemblies.

I I

Quad Cities I and 2 3.3.1.1-9