ML020440561

From kanterella
Jump to navigation Jump to search
Procedure No. EI-1, Revision 38, Emergency Classification and Actions
ML020440561
Person / Time
Site: Palisades Entergy icon.png
Issue date: 01/15/2002
From: Brunet J
Consumers Energy
To: Mcknight J
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML020440561 (3)


Text

Date Entered: Jan 15, 2002 TO:

USNRCIWASHINGTON JMCKNIGHT Copy Number:

145 TRANSMITAL NUME:298 PROCEDURE NUMBER: El-1 TITLE: EMERGENCY CLASSIFICATION AND ACTIONS TRANSMITTAL: LISTED BELOW ARE NEW/REVISED PROCEDURES WHICH MUST BE IMMEDIATELY INSERTED INTO OR DISCARDED FROM YOUR PROCEDURE MANUAL.

Action Required REMOVE AND DESTROY REPLACE WITH Section or Description El-I, R/38, COVERSHEET AND ATTACHMENT 1, PAGE 17 El-I, R/38, COVERSHEET AND ATTACHMENT 1, PAGE 17 EDITORIAL SIGN, DATE, AND RETURN THE ACKNOWLEDGEMENT FORM WITHIN 10 DAYS TO THE PALISADES PLANT DOCUMENT CONTROL.

SIGNATURE OR INITIALS DATE

1

Procedure No El-1 Revision 38 Issued Date 1/15/02 PALISADES NUCLEAR PLANT EMERGENCY IMPLEMENTING PROCEDURE TITLE: EMERGENCY CLASSIFICATION AND ACTIONS Procedure Sponsor Date GGPalmisano

/ 12/6/01 Technical Reviewer Date User Reviewer Date

ProL.do El-1 Revision 38 Page 17 of 26 SITE EMERGENCY PLAN CLASSIFICATION PRIMARY COOLANT SYSTEM INTEGRITY CLASSIFICATION EMERGENCY ACTION LEVEL METHOD OF DETECTION ACTIONS UNUSUAL EVENT Unidentified or pressure boundary Calculation, OR implementation of Mandatory: 1, 3, 4, 6, 7 leakage > 10 gpm.

Off Normal Procedure ONP-23.1, "Primary Coolant Leak," OR SED Subsequent: 15, 22 Identified leakage >25 gpm.

opinion that leak rate indications warrant activation of Emergency If Needed: None Plan. (See NOTE 1)

Steam Generator secondary water S/G sample analysis.

activity > 0.1pCi/gm dose equivalent 1-131.

Primary to secondary leakage Calculation, QR implementation of through any one SG Ž432 gallons Off Normal Procedure ONP-23.2, per day (0.3 gpm) but <50 gpm.

"Steam Generator Tube Leak."

ALERT NOTE: Refer to Fission Product Barrier/Fuel Damage SITE AREA EMERGENCY NOTE: Refer to Fission Product Barrier/Fuel Damage GENERAL EMERGENCY NOTE: Refer to Fission Product Barrier/Fuel Damage NOTE:

1.

Lifting of RV-2006 (Letdown Relief) as expected for plant conditions or evolutions does not require activating the emergency plan.