RAI, Safety Limit Minimum Critical Power Ratio
ML020390179
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 02/08/2002
From: Jabbour K
NRC/NRR/DLPM/LPD2
To: Scalice J
Tennessee Valley Authority
Jabbour K, 415-1496
References
TAC MB3485
Download: ML020390179 (4)


Text

February 8, 2002 Mr. J. A. Scalice Chief Nuclear Officer and Executive Vice President Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION RELATED TO TECHNICAL SPECIFICATION REVISION FOR BROWNS FERRY NUCLEAR PLANT, UNIT 3 (TAC NO. MB3485)

Dear Mr. Scalice:

By letter dated November 1, 2001, Tennessee Valley Authority submitted an application to revise the Technical Specifications (TS) for the Browns Ferry Nuclear Plant, Unit 3. The proposed revision includes a change to the safety limit minimum critical power ratio value in TS 2.1.1.2. The U.S. Nuclear Regulatory Commission staff has reviewed your submittal and finds that a response to the enclosed request for additional information is needed before we can complete the review.

This request was discussed with Mr. T. Abney of your staff on February 7, 2002, and it was agreed that a response would be provided within 30 days of receipt of this letter.

If you have any questions, please contact me at (301) 415-1496.

Sincerely,

/RA/

Kahtan N. Jabbour, Senior Project Manager, Section 2 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-296

Enclosure:

Request for Additional Information cc w/encl: See next page

ML020390179 OFFICE PM:PDII-2 LA:PDII-2 SRXB/SC SC:PDII-2 NAME KJabbour BClayton RCaruso RCorreia DATE 2/7/2002 2/ 7/2002 2/ 8 /2002 2/ 7/2002

REQUEST FOR ADDITIONAL INFORMATION RELATED TO PROPOSED TECHNICAL SPECIFICATION REVISION TENNESSEE VALLEY AUTHORITY BROWNS FERRY NUCLEAR PLANT, UNIT 3 DOCKET NO. 50-296

1. The NRC staff had found discrepancies in data bases while conducting an audit of General Electrics GEXL14 correlation analysis. Please provide justification regarding the applicability of the overall GEXL14 uncertainty to Browns Ferry Unit 3. Please discuss the impact on the safety limit minimum critical power ratio (SLMCPR) calculation due to these discrepancies.
2. It appears that the proposed Technical Specification (TS) SLMCPR value for two-recirculation-loop operation based on the calculated SLMCPR given in Table 2 of Enclosure 5 should be 1.08 in conjunction with the contribution from Question 1. Please provide justification for the proposed TS SLMCPR value of 1.07.

Enclosure

Mr. J. A. Scalice BROWNS FERRY NUCLEAR PLANT Tennessee Valley Authority cc:

Mr. Karl W. Singer, Senior Vice President Nuclear Operations Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. Jon R. Rupert, Vice President (Acting)

Engineering & Technical Services Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. Ashok S. Bhatnagar, Site Vice President Browns Ferry Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Decatur, AL 35609 General Counsel Tennessee Valley Authority ET 11A 400 West Summit Hill Drive Knoxville, TN 37902 Mr. Robert J. Adney, General Manager Nuclear Assurance Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. Robert G. Jones, Plant Manager Browns Ferry Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Decatur, AL 35609 Mr. Mark J. Burzynski, Manager Nuclear Licensing Tennessee Valley Authority 4X Blue Ridge 1101 Market Street Chattanooga, TN 37402-2801 Mr. Timothy E. Abney, Manager Licensing and Industry Affairs Browns Ferry Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Decatur, AL 35609 Senior Resident Inspector U.S. Nuclear Regulatory Commission Browns Ferry Nuclear Plant l0833 Shaw Road Athens, AL 35611 State Health Officer Alabama Dept. of Public Health RSA Tower - Administration Suite 1552 P.O. Box 303017 Montgomery, AL 36130-3017 Chairman Limestone County Commission 310 West Washington Street Athens, AL 35611