ML020310536

From kanterella
Jump to navigation Jump to search
Drawing E-232-408-5, General Arrangement Elevation for Omaha Power 140 I.D. Pwr
ML020310536
Person / Time
Site: Fort Calhoun 
(DPR-040)
Issue date: 01/09/2002
From:
Combustion Engineering
To:
Office of Nuclear Reactor Regulation
References
E-232-408-5
Download: ML020310536 (1)


Text

LR-RV LR-RC LR-RV LR-RC LR-RV LR-RV*

LR-RV LR-RV**

Flow skirt is covered in the Reactor Vessel Internal (RVI) EA.

LR-RV*

LR-RV

  • - ICI housings are within the scope of License Renewal Boundary in the RV System.
      • - Boundary is at valve RC-100.

LR-RV LR-RC***

FOR INFORMATION ONLY NOTE: THIS PRINT IS TO BE USED FOR THE FCS LICENSE RENEWAL PROJECT ONLY.

IT MAY NOT REFLECT THE MOST CURRENT REVISION OF THIS DRAWING.

  • UNLESS OTHERWISE INDICATED, VENTS, DRAINS AND TEST CONNECTIONS THAT ARE WITHIN LICENSE RENEWAL BOUNDARIES ARE INCLUDED IN LR SCOPE TO THE DISCHARGE OF THE VALVE.
  • ALL INSTRUMENTATION LINES NORMALLY OPEN TO THE PROCESS SYSTEM, THROUGH AND INCLUDING THE INSTRUMENT, ARE INCLUDED IN LR SCOPE.
  • IN GENERAL, LR FLAGS ARE NOT SHOWN FOR VENTS, DRAINS, TEST CONNECTIONS OR INSTRUMENT LINES EXCEPT FOR CONTAINMENT PENETRATIONS.
  • THE LICENSE RENEWAL BOUNDARY INCLUDES THE PIPING AND SUPPORTS UP TO THE FIRST SEISMIC SUPPORT PAST THE BLUE BOUNDARY FLAG.

EA-FC-00-133 DF 12/01 EA-FC-00-133 DF 12/01