Sheet 1 of 151 ri ENERCON F*
SERVICES, INC. Appendix RL-4 to Calculation PGE-009-CALC-003 Originator:
S. C. Tumminelli Date:
November 30, 2001 Appendix RL-4 Reaction Loads - Cask Placement Sequence This Appendix presents reaction loads of the model for eight Hosgri HE(1) Load Cases, aimed at 45 degrees around the compass.
The first part of the calculation computes the expected forces. Input values are from References 2 and 4.
The sum of all applied loads are calculated followed by the sum of the forces at the pad/rock interface and the sum at the boundary of the rock. Since the rock is massless, the last two values are the same.
These are presented in Tables 1 through 3, for the sets of analyses performed. The first set is for casks placed from number 1 through 1 to 6, Table 1 (42 Load Cases). The second set is for casks placed from I to 7 through 1 to 10, Table 2 (26 Load Cases), and the last set is for casks placed from 1 to 11 through 1 to 14, Table 3 (26 Load Cases). The forces computed and provided in the Tables are the applied forces, with sign.
Then the databases are scanned for the same data. The input and output files are provided in sequence.
The ANSYS program is providing the unbalanced forces that the elements are applying to the nodes.
Thus, the values for the nodes where the loads are applied, are actually the reactions that the elements are applying to these nodes to maintain equilibrium. Hence, the values are the negative of the applied loads. On the boundary, the values are again the forces that the elements are applying to the nodes. Thus, they have the same sign as the applied loads calculated and provided in the Tables.
A comparison of the expected forces and the forces scanned from the soft rock analysis database shows that the values are the same. This indicates that the pad is in equilibrium and that, together with a review of the displacement plots, provides high confidence that the analyses are correct.
Appendix Contents Manual reaction calculations sheet 2 ANSYS input file for reactions for casks 1 through 1 to 6 sheet 9 ANSYS output file for reactions for casks 1 through 1 to 6 sheet 24 ANSYS input file for reactions for casks 1 to 7 through 1 to 10 sheet 72 ANSYS output file for reactions for casks 1 to 7 through 1 to 10 sheet 82 ANSYS input file for reactions for casks 1 to 11 through 1 to 14 sheet 112 ANSYS output file for reactions for casks 1 to 11 through 1 to 14 sheet 122
ENERCON Sheet 2 of 151 F A SERVICES, INC. Appendix RL-4 to Calculation PGE-009-CALC-003 Compute the various force components of the cask(s) and the pad at 45 degrees around the compass:
Hosgri (HE(l)) Force Components 100-40-40 rule:
Horizontal Force =
515000 per cask Vertical Force =
267040 down per cask Pad weight 68*105*7.5* 150 = 8032500 pounds Pad seismic horizontal force = 0.808*8032500 =
6490260 Pad seismic vertical force = 0.800*8032500 =
6426000 Components @ 45 degrees:
Horizontal Force =
0.707*515000 =
364160 per cask Pad seismic horizontal force = 0.707*0.808*8032500 =
4586558 (where 0.707*0.808 = 0.571)
The tables were created simply by adding the applied cask load components to the applied ZPA pad seismic load component.
As an example:
Say 12 casks at N 45 W (See Table 3 (1 of 2)):
Horizontal:
Cask load = 12*364160 =
4369920 Pad load=
4586558 Total=
8956478 Vertical:
Cask load = 12*267040 =
3204480 Pad load=
6426000 Total =
9630480 All forces are computed in a similar manner.
F
'I ENERCON F SERVICES, INC. Appendix RL-4 to Calculation PGE-009-CALC-003 Table 1 (1 of 2) - Reaction loads for Casks 1 through 1 to 6 Sheet 3 of 151 Direction Forces Number of Casks on Pad in Sequence of Seismic 1
2 3
4 5
6 Accel.
N Cask Fx 0
0 0
0 0
0 Load Fy
-267040
-534080
-801120
-1068160
-1335200
-1602240 Steps Fz 515000 1030000 1545000 2060000 2575000 3090000 1,9,17,25, Rock Fx 0
0 0
0 0
0 30 and 38 Fy
-6693040
-6960080
-7227120
-7494160
-7761200
-8028240 Fz 7005260 7520260 8035260 8550260 9065260 9580260 N45W Cask Fx 364160 728320 1092480 1456640 1820800 2184960 Load Fy
-267040
-534080
-801120
-1068160
-1335200
-1602240 Steps Fz 364160 728320 1092480 1456640 1820800 2184960 2,10,18, Rock Fx 4950717 5314877 5679037 6043197 6407357 6771517 26,31 and Fy
-6693040
-6960080
-7227120
-7494160
-7761200
-8028240 39 Fz 4950717 5314877 5679037 6043197 6407357 6771517 W
Cask Fx 515000 1030000 1545000 2060000 2575000 3090000 Load Fy
-267040
-534080
-801120
-1068160
-1335200
-1602240 Steps Fz 0
0 0
0 0
0 3,11,19, Rock Fx 7005260 7520260 8035260 8550260 9065260 9580260 27,32 and Fy
-6693040
-6960080
-7227120
-7494160
-7761200
-8028240 40 Fz 0
0 0
0 0
0 S 45W Cask Fx 364160 728320 1092480 1456640 1820800 2184960 Load Fy
-267040
-534080
-801120
-1068160
-1335200
-1602240 Steps Fz
-364160
-728320
-1092480
-1456640
-1820800
-2184960 4,12,20, Rock Fx 4950717 5314877 5679037 6043197 6407357 6771517 28,33 and Fy
-6693040
-6960080
-7227120
-7494160
-7761200
-8028240 41 Fz
-4950717
-5314877
-5679037
-6043197
-6407357
-6771517
r I* ENERCON F, SERVICES, INC. Appendix RL-4 to Calculation PGE-009-CALC-003 Table 1 (2 of 2) - Reaction loads for Casks 1 through 1 to 6 Sheet 4 of 151 Direction Forces Number of Casks on Pad in Sequence of Seismic 1
2 3
4 5
6 Accel.
I S
Cask Fx 0
0 0
0 0
0 Load Fy
-267040
-534080
-801120
-1068160
-1335200
-1602240 Steps Fz
-515000
-1030000
-1545000
-2060000
-2575000
-3090000 5,13,21, Rock Fx 0
0 0
0 0
0 29,34 and Fy
-6693040
-6960080
-7227120
-7494160
-7761200
-8028240 42 Fz
-7005260
-7520260
-8035260
-8550260
-9065260
-9580260 S 45 E Cask Fx
-364160
-728320
-1092480
-1820800 Load Fy
-267040
-534080
-801120 SYM with
-1335200 SYM with Steps Fz
-364160
-728320
-1092480 S 45 W
-1820800 S45W 6,14,22, Rock Fx
-4950717
-5314877
-5679037
-6407357 and 35 Fy
-6693040
-6960080
-7227120
-7761200 Fz
-4950717
-5314877
-5679037
-6407357 E
Cask Fx
-515000
-1030000
-1545000
-2575000 Load Fy
-267040
-534080
-801120 SYM with
-1335200 SYM with Steps Fz 0
0 0
W 0
W 7,15,23, Rock Fx
-7005260
-7520260
-8035260
-9065260 and 36 Fy
-6693040
-6960080
-7227120
-7761200 Fz 0
0 0
0 N 45 E Cask Fx
-364160
-728320
-1092480
-1820800 Load Fy
-267040
-534080
-801120 SYM with
-1335200 SYM with Steps Fz 364160 728320 1092480 N45W 1820800 N 45 W 8,16,24, Rock Fx
-4950717
-5314877
-5679037
-6407357 and 37 Fy
-6693040
-6960080
-7227120
-7761200 Fz 4950717 5314877 5679037 6407357
EFA Sheet 5 of 151 ENERCON SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 Table 2 (1 of 2) - Reaction loads for Casks 1 to 7 through 1 to 10 Direction Forces Number of Casks on Pad in Sequence of Seismic 7
8 9
10 Accel.
- N Cask Fx 0
0 0
0 Load Fy
-1869280
-2136320
-2403360
-2670400 Steps Fz 3605000 4120000 4635000 5150000 1,9,14and RockFx 0
0 0
0 22 Fy
-8295280
-8562320
-8829360
-9096400 Fz 10095260 10610260 11125260 11640260 N45W Cask Fx 2549120 2913280 3277440 3641600 Load Fy
-1869280
-2136320
-2403360
-2670400 Steps Fz 2549120 2913280 3277440 3641600 2,10,15 Rock Fx 7135677 7499837 7863997 8228157 and 23 Fy
-8295280
-8562320
-8829360
-9096400 Fz 7135677 7499837 7863997 8228157 W
Cask Fx 3605000 4120000 4635000 5150000 Load Fy
-1869280
-2136320
-2403360
-2670400 Steps Fz 0
0 0
0 3,11,16 Rock Fx 10095260 10610260 11125260 11640260 and 24 Fy
-8295280
-8562320
-8829360
-9096400 Fz 0
0 0
0 S45W Cask Fx 2549120 2913280 3277440 3641600 Load Fy
-1869280
-2136320
-2403360
-2670400 Steps Fz
-2549120
-2913280
-3277440
-3641600 4,12,17 Rock Fx 7135677 7499837 7863997 8228157 and 25 Fy
-8295280
-8562320
-8829360
-9096400 Fz
-7135677
-7499837
-7863997
-8228157
A ENERCON SERVICES, INC. Appendix RL-4 to Calculation PGE-009-CALC-003 Table 2 (2 of 2) - Reaction loads for Casks 1 to 7 through 1 to 10 Sheet 6 of 151 Direction Forces Number of Casks on Pad in Sequence of Seismic 7
8 9
10 Accel.
S Cask Fx 0
0 0
0 Load Fy
-1869280
-2136320
-2403360
-2670400 Steps Fz
-3605000
-4120000
-4635000
-5150000 5,13,18 Rock Fx 0
0 0
0 and 26 Fy
-8295280
-8562320
-8829360
-9096400 Fz -10095260
-10610260
-11125260
-11640260 S 45 E Cask Fx
-2549120
-3277440 Load Fy
-1869280 SYM with
-2403360 SYM with Steps Fz
-2549120 S 45 W
-3277440 S 45 W 6 and 19 RockFx
-7135677
-7863997 Fy
-8295280
-8829360 Fz
-7135677
-7863997 E
Cask Fx
-3605000
-4635000 Load Fy
-1869280 SYM with
-2403360 SYM with Steps Fz 0
W 0
W 7 and 20 Rock Fx -10095260
-11125260 Fy
-8295280
-8829360 Fz 0
0 N 45 E Cask Fx
-2549120
-3277440 Load Fy
-1869280 SYM with
-2403360 SYM with Steps Fz 2549120 N 45 W 3277440 N 45 W 8 and 21 RockFx
-7135677
-7863997 Fy
-8295280
-8829360 Fz 7135677 7863997
Sheet 7 of 151 F 'I ENERCON SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 Table 3 (1 of 2) - Reaction loads for Casks 1 to 11 through 1 to 14 Direction Forces Number of Casks on Pad in Sequence of Seismic 11 12 13 14 Accel.
N Cask Fx 0
0 0
0 Load Fy
-2937440
-3204480
-3471520
-3738560 Steps Fz 5665000 6180000 6695000 7210000 1,9,4 and Rock Fx 0
0 0
0 22 Fy
-9363440
-9630480
-9897520
-10164560 Fz 12155260 12670260 13185260 13700260 N45W Cask Fx 4005760 4369920 4734080 5098240 Load Fy
-2937440
-3204480
-3471520
-3738560 Steps Fz 4005760 4369920 4734080 5098240 2,10,15 Rock Fx 8592317 8956477 9320637 9684797 and 23 Fy
-9363440
-9630480
-9897520
-10164560 Fz 8592317 8956477 9320637 9684797 W
Cask Fx 5665000 6180000 6695000 7210000 Load Fy
-2937440
-3204480
-3471520
-3738560 Steps Fz 0
0 0
0 3,11,16 Rock Fx 12155260 12670260 13185260 13700260 and 24 Fy
-9363440
-9630480
-9897520
-10164560 Fz 0
0 0
0 S 45 W Cask Fx 4005760 4369920 4734080 5098240 Load Fy
-2937440
-3204480
-3471520
-3738560 Steps Fz
-4005760
-4369920
-4734080
-5098240 4,12,17 Rock Fx 8592317 8956477 9320637 9684797 and 25 Fy
-9363440
-9630480
-9897520
-10164560 Fz
-8592317
-8956477
-9320637
-9684797
ENERCON F A SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 Table 3 (2 of 2) - Reaction loads for Casks 1 to 11 through 1 to 14 Sheet 8 of 151 Direction Forces Number of Casks on Pad in Sequence of Seismic 11 12 13 14 Accel.
S Cask Fx 0
0 0
0 Load Fy
-2937440
-3204480
-3471520
-3738560 Steps Fz
-5665000
-6180000
-6695000
-7210000 5,13,18 Rock Fx 0
0 0
0 and 26 Fy
-9363440
-9630480
-9897520
-10164560 Fz -12155260
-12670260
-13185260
-13700260 S 45 E Cask Fx
-4005760
-4734080 Load Fy
-2937440 SYM with
-3471520 SYM with Steps Fz
-4005760 S 45 W
-4734080 S 45 W 6 and 19 RockFx
-8592317
-9320637 Fy
-9363440
-9897520 Fz
-8592317
-9320637 E
Cask Fx
-5665000
-6695000 Load Fy
-2937440 SYM with
-3471520 SYM with Steps Fz 0
W 0
W 7 and 20 Rock Fx -12155260
-13185260 Fy
-9363440
-9897520 Fz 0
0 N 45 E Cask Fx
-4005760
-4734080 Load Fy
-2937440 SYM with
-3471520 SYM with Steps Fz 4005760 N45W 4734080 N45 W 8 and 21 Rock Fx
-8592317
-9320637 Fy
-9363440
-9897520 Fz 8592317 9320637
Sheet 9 of 151 S
ENERCON F-SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 ANSYS input file for processing reaction loads for casks 1 through 1 to 6:
/com,
/com, This routine processes load results data for the
/com, evaluation of equilibrium.
/com
/com, Soft Rock Load Step Results for Cask Load Sequence 1
/com, This is for load sequence for casks 1 through 6
/com
/output,padsoftreacseql,out
/com
/com
/com
/com
/com
/com
/com
/com
/com Soft Rock Reactions ****************************
/com
/file,dcslabs7 resume
/postl eall nall
/com
/com
- ww*********.*******
/com LOAD CASE 1*
set,1 eall cmsel,s,cask
/comr
/com
- SUM OF LOADS APPLIED TO CASKS fsum esel,type, l cmsel,s,base
/com
/com
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
- fsum esel,type, 2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com
/com *************************
LOAD CASE 2
- set,2 eall cmsel,s,cask
/com
/com ********
SUM OF LOADS APPLIED TO CASKS
- fsum esel,type,1 cmsel,s,base
/com
Sheet 10 of 151 F
~
ENERCON SERVICES, INC.
Appendix RL4 to Calculation PGE-009-CALC-003
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com ********
LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com *************************
LOAD CASE set,3 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
- fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com LOAD CASE 4
- set,4 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type, l cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2
/com cmsel,s,boundary
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com LOAD CASE 5 set,5 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *****
fsum esel,type,l cmsel,s,base
/com
Sheet 11 of 151 F 'lIENERCON SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
fsum esel,type,2 cmsel,s,boundary
/Com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com LOAD CASE 6 **********************************
set,6 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
fsum esel,type,2 cmsel,s,boundary
/com
/com
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com LOAD CASE 7 **********************************
set,7 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
/com ********
LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/comr
/com *************************
LOAD CASE 8 **********************************
set,8 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,l cmsel,s,base
/com
Sheet 12 of 151 ENERCON F
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003
/com
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/Com
/com
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
fsum
/com
/ corn **~***********************************************************************
/com LOAD CASE 9 set,9 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
/com ******** LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/ corn *************************************************************************
/com LOAD CASE 10
- set,10 eall cmsel,s,cask
/com
/com ********
SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
/com ********
LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com ********
LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
fsum
/com
/com *************************
LOAD CASE 11 *********************************
set,11 eall cmsel,s,cask
/Com
/com SUM OF LOADS APPLIED TO CASKS *****
fsum esel,type,l cmsel,s,base
/com
Sheet 13 of 151 F' 4ENERCON A SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/Com
/com LOAD CASE 12 *********************************
set,12 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS
- fsum esel,type,l cmsel,s,base
/com
/com
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
fsum esel,type, 2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com LOAD CASE 13 set,13 eall cmsel,s,cask
/com
/com ********
SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
/com ********
LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
fsum esel,type,2 cmsel,s,boundary
/com
/com ******** LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com LOAD CASE 14
- set,14 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
Sheet 14 of 151 C'
'JENERCON SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
- fsum esel,type,2 cmsel,s,boundary
/Com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com LOAD CASE 15 *********************************
set,15 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/Com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com
/com LOAD CASE 16 set,16 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
/com ********
LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
fsum esel,type,2 cmsel,s,boundary
/com
/com ********
LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
fsum
/com
/oom
/com
- k***************
LOAD CASE 17
- set,17 eall cmsel,s,cask
/Com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
Sheet 15 of 151 JENERCON F
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/comr
/com LOAD CASE 18 *********************************
set,18 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l
.cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS
- fsum
/com
/com************************************************************
/com LOAD CASE 19 *********************************
set,19 eall cmsel,s,cask
/com
/com
- SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,l cmsel,s,base
/com
/com ********
LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
- fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com
/com LOAD CASE 20 *********************************
set,20 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,l cmsel,s,base
/com
Sheet 16 of 151 r
jENERCON F~ SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
- fsum esel,type,2 cmsel,s,boundary
/Com
/com
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com *************************************************************************
/com LOAD CASE 21 *********************************
set,21 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *****
fsum esel,type,l cmsel,s,base
/com
/com ********
LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
fsum
/com
/com
/com LOAD CASE 22
- set,22 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *****
fsum esel,type,l cmsel,s,base
/Com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com
/com LOAD CASE 23 set,23 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,l cmsel,s,base
/com
Sheet 17 of 151 3
E RCON SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003
/oom LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2
/com cmsel,s,boundary
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
fsum
/com
/com******************************************
/com LOAD CASE 24 *********************************
set,24 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,l cmsel,s,base
/com
/com ********
LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
fsum
/com
/com LOAD CASE 25
- set,25 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,l cmsel,s,base
/com
/com ********
LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
fsum
/com
/com LOAD CASE 26
- set,26 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,l cmsel,s,base
/com
Sheet 18 of 151 r
'j ENERCON F HI SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/Com
/com
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/ c o m******* ******
/com LOAD CASE 27
- set,27 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
fsum esel,type,2 cmsel,s,boundary
/Com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com *************************
LOAD CASE 28
- set,28 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com*******
/com LOAD CASE 29
- set,29 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
Sheet 19 of 151 r°NERCON SSERVICES, INC.
Appendix RL4 to Calculation PGE-009-CALC-003
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
fsum
/com
/com LOAD CASE 30 *********************************
set,30 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
/com ******** LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
fsum
/com
/com LOAD CASE 31
- set,31 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,l cmsel,s,base
/com
/com ********
LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
fsum
/com
/com LOAD CASE 32
- set,32 eall cmsel,s,cask
/Com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
Sheet 20 of 151 F il ENERCON SERVICES, INC.
Appendix RL4 to Calculation PGE-009-CALC-003
/com
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
- fsum esel,type,2 cmsel,s,boundary
/com
/com ******** LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com
/com LOAD CASE 33 *********************************
set,33 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/Com
/com
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
- fsum esel,type,2 cmsel,s,boundary
/com
/com ********
LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com
/com LOAD CASE 34 *********************************
set,34 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,l cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com
/com LOAD CASE 35
- set,35 eall cmsel,s,cask
/com
/com ********
SUM OF LOADS APPLIED TO CASKS
- fsum esel,type,l cmsel,s,base
/com
Sheet 21 of 151 SERCON F
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
- fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS f sum
/Com
/COrn *************************************************************************
/com LOAD CASE 36 *********************************
set,36 eall cmsel,s,cask
/com
/com
- SUM OF LOADS APPLIED TO CASKS f sum esel,type,l cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE ******
fsum esel,type,2 cmsel,s,boundary
/com
/com
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
fsum
/com
/ corn *************************************************************************
/com LOAD CASE 37
- set,37 eall cmsel,s,cask
/com
/com ********
SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel, s,base
/com
/com
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
fsum esel,type,2 cmsel,s,boundary
/com
/com
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
fsum
/com
/com LOAD CASE 38 *********************************
set,38 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *******
f sum esel,type, 1 cmsel,s,base
/com
Sheet 22 of 151 r.1 SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
- fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com
/ corn *************************************************************************
/com LOAD CASE 39 *********************************
set,39 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type, l cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com
/com LOAD CASE 40 *********************************
set,40 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,l cmsel,s,base
/com
/com ********
LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/Com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
fsum
/com
/com
/com LOAD CASE 41 *********************************
set,41 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *****
fsum esel,type,l cmsel,s,base
Sheet 23 of 151 F 'IENERCON F
SERVICES, INC. Appendix RL-4 to Calculation PGE-009-CALC-003
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com ********
LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com
/com *************************
LOAD CASE 42 *********************************
set,42 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
fsum
/com
/com eall nall fini
/output
/exit
EERCON A SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 ANSYS output file for reaction loads for casks 1 through 1 to 6:
Sheet 24 of 151
- Soft Rock Reactions ***********************
CURRENT JOBNAME REDEFINED AS dcslabs7 RESUME ANSYS DATA FROM FILE NAME=dcslabs7.db ANSYS GLOBAL STATUS ***
TITLE = Pad, HE(1),
Casks 1 to 6, 515 Kips South (-Z),
Soft ANALYSIS TYPE =
STATIC (STEADY-STATE)
NUMBER OF ELEMENT TYPES =
6 1728 ELEMENTS CURRENTLY SELECTED.
MAX ELEMENT NUMBER 731 NODES CURRENTLY SELECTED.
MAX NODE NUMBER =
259 KEYPOINTS CURRENTLY SELECTED.
MAX KEYPOINT NUMBER
=
250 LINES CURRENTLY SELECTED.
MAX LINE NUMBER =
181 AREAS CURRENTLY SELECTED.
MAX AREA NUMBER =
70 VOLUMES CURRENTLY SELECTED.
MAX VOL.
NUMBER =
25 COMPONENTS CURRENTLY DEFINED MAXIMUM LINEAR PROPERTY NUMBER
=
5 MAXIMUM REAL CONSTANT SET NUMBER
=
6 ACTIVE COORDINATE SYSTEM
=
0 (CARTESIAN)
MAXIMUM CONSTRAINT EQUATION NUMBER
=
4620 NUMBER OF SPECIFIED CONSTRAINTS 2193 NUMBER OF NODAL LOADS
=
648 Rock 33177 17051 259 396 295 70 INITIAL JOBNAME = dcslabs7 CURRENT JOBNAME = dcslabs7 ANSYS ENGINEERING ANALYSIS SYSTEM RELEASE 5.7 ANSYS/Structural U 00150104 VERSION=INTEL NT 12:49:55 JUN 11, 2001 CP=
Pad, HE(l),
Casks 1 to 6, 515 Kips South (-Z),
Soft Rock ANSYS RESULTS INTERPRETATION (POST1) 1.182 ENTER
/SHOW,DEVICE-NAME ENTER FINISH TO ENABLE GRAPHIC DISPLAY TO LEAVE POST1 NOTE CP=
1.182 TIME= 12:49:55 Reading results into the database (SET command) will update the current displacement and force boundary conditions in the database with the values from the results file for that load set.
Note that any subsequent solutions will use these values unless action is taken to
Sheet 25 of 151 ENERCON F
SERVICES, INC. Appendix RL-4 to Calculation PGE-009-CALC-003 either SAVE the current values or not overwrite them (/EXIT,NOSAVE).
15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
17051 NODES (OF 17051 DEFINED) SELECTED BY NALL COMMAND.
LOAD CASE 1 **********************************
USE LOAD STEP 1
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
1 SUBSTEP=
1 CUMULATIVE ITERATION=
4 TIME/FREQUENCY=
1.0000 TITLE= Pad, HE(1),
Cask 1, 515 Kips North (Z),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES ****
FX
= -0.3404712E-06 FY
=
267040.0 FZ
=
-515000.0 MX
=
0.1568771E+09 MY
=
0.1050600E+09 MZ
=
0.5447616E+08 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.4548610E-05 FY
=
-6693040.
FZ
=
7005260.
MX
= -0.3070747E+10 MY
= -0.2091080E+10 MZ
-0.2020832E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS
- Sheet 26 of 151 SENERCON F *SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.9994679E-03 FY
=
-6693040.
FZ
=
7005260.
MX
= -0.3070747E+10 MY
= -0.2091080E+10 MZ
-0.2020832E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 2 **********************************
USE LOAD STEP 2
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
2 SUBSTEP=
1 CUMULATIVE ITERATION=
8 TIME/FREQUENCY=
2.0000 TITLE= Pad, HE(1),
Cask 1, 515 Kips N 45 W (ZX),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF.LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-364160.0 FY
=
267040.0 FZ
=
-364160.0 MX
=
0.1747517E+09 MY
=
0.3714432E+09 MZ
=
0.9762912E+08 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
4950717.
FY
=
-6693040.
FZ
=
4950717.
MX
= -0.3002955E+10 MY
= -0.3646245E+10 MZ
-0.1857590E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
Sheet 27 of 151 F
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
4950717.
FY
=
-6693040.
FZ
=
4950717.
MX
= -0.3002955E+10 MY
= -0.3646245E+10 MZ
-0.1857590E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 3 **********************************
USE LOAD STEP 3
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
3 SUBSTEP=
1 CUMULATIVE ITERATION=
13 TIME/FREQUENCY=
3.0000 TITLE= Pad, HE(l),
Cask 1, 515 Kips West (X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-515000.0 FY
=
267040.0 FZ
= -0.1914207E-05 MX
=
0.2179046E+09 MY
=
0.4202400E+09 MZ
=
0.1155037E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
7005260.
FY
=
-6693040.
FZ
= -0.5576921E-06 MX
= -0.2839713E+I10 MY
= -0.3068266E+10 MZ
= -0.1789798E+10
r
'5 ENERCON Sheet 28 of 151 r.
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
7005260.
FY
=
-6693040.
FZ
= -0.5525149E-03 MX
= -0.2839713E+10 MY
= -0.3068266E+10 MZ
-0.1789798E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 4 **********************************
USE LOAD STEP 4
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
4 SUBSTEP=
1 CUMULATIVE ITERATION=
18 TIME/FREQUENCY=
4.0000 TITLE= Pad, HE(1),
Cask 1, 515 Kips S 45 W (-ZX),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
-364160.0 FY
=
267040.0 FZ
=
364160.0 MX
=
0.2610576E+09 MY
=
0.2228659E+09 MZ
=
0.9762912E+08 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED) SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
4950717.
Sheet 29 of 151 F
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 FY
=
-6693040.
FZ
=
-4950717.
MX
= -0.2676471E+10 MY
= -0.6906948E+09 MZ
-0.1857590E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS ******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
4950717.
FY
=
-6693040.
FZ
=
-4950717.
MX
= -0.2676471E+10 MY
= -0.6906948E+09 MZ
-0.1857590E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 5 **********************************
USE LOAD STEP 5
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
5 SUBSTEP=
1 CUMULATIVE ITERATION=
21 TIME/FREQUENCY=
5.0000 TITLE= Pad, HE(l),
Cask 1, 515 Kips South (-Z),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1149842E-04 FY
=
267040.0 FZ
=
515000.0 MX
=
0.2789321E+09 MY
= -0.1050600E+09 MZ
=
0.5447616E+08 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE
Sheet 30 of 151 r
'j ENERCON F A SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.8825099E-04 FY
=
-6693040.
FZ
=
-7005260.
MX
= -0.2608678E+10 MY
=
0.2091080E+10 MZ
-0.2020832E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS ******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.5599402E-03 FY
=
-6693040.
FZ
=
-7005260.
MX
= -0.2608678E+10 MY
=
0.2091080E+10 MZ
-0.2020832E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 6 **********************************
USE LOAD STEP 6
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
6 SUBSTEP=
1 CUMULATIVE ITERATION=
25 TIME/FREQUENCY=
6.0000 TITLE= Pad, HE(l),
Cask 1, 515 Kips S 45 E (-Z,-X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
364160.0 FY
=
267040.0 FZ
=
364160.0 MX
=
0.2610576E+09 MY
= -0.3714432E+09 MZ
=
0.1132320E+08 SUMMATION POINT=
0.0000 0.0000 0.0000
Sheet 31 of 151 F 'U ENERCON FSERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
-4950717.
FY
=
-6693040.
FZ
=
-4950717.
MX
= -0.2676471E+10 MY
=
0.3646245E+10 MZ
-0.2184074E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-4950717.
FY
=
-6693040.
FZ
=
-4950717.
MX
= -0.2676471E+10 MY
=
0.3646245E+10 MZ
-0.2184074E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 7 USE LOAD STEP 7
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
7 SUBSTEP=
1 CUMULATIVE ITERATION=
29 TIME/FREQUENCY=
7.0000 TITLE= Pad, HE(1),
Cask 1, 515 Kips East (-x),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
515000.0 FY
=
267040.0 FZ
=
0.2208788E-05 MX
=
0.2179046E+09
Sheet 32 of 151 FERV
, INC.
Appendix RL4 to Calculation PGE-009-CALC-003 MY
= -0.4202400E+09 MZ
=
-6551340.
SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE ******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-7005260..
FY
=
-6693040.
FZ
=
0.1077171E-04 MX
= -0.2839713E+10 MY
=
0.3068266E+10 MZ
-0.2251866E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED) SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-7005260.
FY
=
-6693040.
FZ
=
0.5919110E-03 MX
= -0.2839713E+10 MY
=
0.3068266E+10 MZ
-0.2251866E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 8 **********************************
USE LOAD STEP 8
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
8 SUBSTEP=
1 CUMULATIVE ITERATION=
33 TIME/FREQUENCY=
8.0000 TITLE= Pad, HE(l),
Cask 1, 515 Kips N 45 E (Z,-X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
Sheet 33 of 151 r'A ENERCON SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
364160.0 FY
=
267040.0 FZ
=
-364160.0 MX
=
0.1747517E+09 MY
= -0.2228659E+09 MZ
=
0.1132320E+08 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-4950717.
FY
=
-6693040.
FZ
=
4950717.
MX
= -0.3002955E+10 MY
=
0.6906948E+09 MZ
-0.2184074E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-4950717.
FY
=
-6693040.
FZ
=
4950717.
MX
= -0.3002955E+10 MY
=
0.6906948E+09 MZ
-0.2184074E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 9 USE LOAD STEP 9
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
9 SUBSTEP=
1 CUMULATIVE ITERATION=
37 TIME/FREQUENCY=
9.0000 TITLE= Pad, HE(1),
Casks 1 and 2, 515 Kips North (Z),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
- n InlI ENERCON Sheet 34 of 151 F
3 SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 SELECT COMPONENT CASK
- SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.3738950E-05 FY
=
534080.0 FZ
=
-1030000.
MX
=
0.2592781E+09 MY
=
0.2101200E+09 MZ
=
0.1089523E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1265460E-04 FY
=
-6960080..
FZ
=
7520260.
MX
= -0.3173148E+10 MY
= -0.2196140E+10 MZ
-0.2075308E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.2443332E-02 FY
=
-6960080.
FZ
=
7520260.
MX
= -0.3173148E+10 MY
= -0.2196140E+10 MZ
-0.2075308E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 10 *********************************
USE LOAD STEP 10 SUBSTEP 0
FOR LOAD CASE 0
Sheet 35 of 151 E
ENERCON F. SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 SET COMMAND GOT LOAD STEP=
10 SUBSTEP=
1 CUMULATIVE ITERATION=
42 TIME/FREQUENCY=
10.000 TITLE= Pad, HE(1),
Casks 1 and 2, 515 Kips N 45 W (Z,X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-728320.0 FY
=
534080.0 FZ
=
-728320.0 MX
=
0.2950272E+09 MY
=
0.6685978E+09 MZ
=
0.1952582E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
5314877.
FY
=
-6960080.
FZ
=
5314877.
MX
= -0.3123230E+10 MY
= -0.3943400E+10 MZ
-0.1955219E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED) SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
5314877.
FY
=
-6960080.
FZ
=
5314877.
MX
= -0.3123230E+10 MY
= -0.3943400E+10 MZ
-0.1955219E+10 SUMMATION POINT
0.0000 0.0000 0.0000
lENERCON Sheet 36 of 151 SERVICES, INC. Appendix RL-4 to Calculation PGE-009-CALC-003 LOAD CASE 11 *********************************
USE LOAD STEP 11 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
11 SUBSTEP=
1 CUMULATIVE ITERATION=
47 TIME/FREQUENCY=
11.000 TITLE= Pad, HE(l),
Casks 1 and 2, 515 Kips West (X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-1030000.
FY
=
534080.0 FZ
=
0.1299095E-05 MX
=
0.3813331E+09 MY
=
0.7354200E+09 MZ
=
0.2310073E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED) SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *****
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
7520260.
FY
=
-6960080.
FZ
=
0.9063054E-05 MX
= -0.3003141E+10 MY
= -0.3383446E+10 MZ
-0.1905302E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS
"***** SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
7520260.
FY
=
-6960080.
FZ
= -0.2246422E-02 MX
= -0.3003141E+10 MY
= -0.3383446E+10
Sheet 37 of 151 F
~
ENERCON SERVICES, INC.
Appendix RL4 to Calculation PGE-009-CALC-003 MZ
-0.1905302E+10 SUMMATION POINT=
0.0000 0.0000 0.0000 LOAD CASE 12 *********************************
USE LOAD STEP 12 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
12 SUBSTEP=
1 CUMULATIVE ITERATION=
52 TIME/FREQUENCY=
12.000 TITLE= Pad, HE(l),
Casks 1 and 2, 515 Kips S 45 W (-Z,X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-728320.0 FY
=
534080.0 FZ
=
728320.0 MX
=
0.4676390E+09 MY
=
0.3714432E+09 MZ
=
0.1952582E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
5314877.
FY
=
-6960080.
FZ
=
-5314877.
MX
= -0.2883052E+10 MY
= -0.8392721E+09 MZ
-0.1955219E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS
"***** SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES
Sheet 38 of 151 F
SERVICES, INC.
Appendix RL4 to Calculation PGE-009-CALC-003 FX
=
5314877.
FY
=
-6960080.
FZ
=
-5314877.
MX
= -0.2883052E+10 MY
= -0.8392721E+09 MZ
-0.1955219E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 13 *********************************
USE LOAD STEP 13 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
13 SUBSTEP=
1 CUMULATIVE ITERATION=
56 TIME/FREQUENCY=
13.000 TITLE= Pad, HE(l),
Casks 1 and 2, 515 Kips South (-Z),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK
- SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.4849905E-05 FY
=
534080.0 FZ
=
1030000.
MX
=
0.5033881E+09 MY
= -0.2101200E+09 MZ
=
0.1089523E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO I BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE ******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.2228251E-05 FY
=
-6960080.
FZ
=
-7520260.
MX
= -0.2833134E+10 MY
=
0.2196140E+10 MZ
-0.2075308E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
Sheet 39 of 151 F
laENERCON F AINC. Appendix RL-4 to Calculation PGE-009-CALC-003 SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.8035135E-03 FY
=
-6960080.
FZ
=
-7520260.
MX
= -0.2833134E+10 MY
=
0.2196140E+10 MZ
-0.2075308E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 14 USE LOAD STEP 14 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
14 SUBSTEP=
1 CUMULATIVE ITERATION=
60 TIME/FREQUENCY=
14.000 TITLE= Pad, HE(1),
Casks 1 and 2, 515 Kips S 45 E (-Z,-X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
728320.0 FY
=
534080.0 FZ
=
728320.0 MX
=
0.4676390E+09 MY
= -0.6685978E+09
.MZ
=
0.2264640E+08 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED) SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-5314877.
FY
=
-6960080.
FZ
=
-5314877.
MX
= -0.2883052E+10 MY
=
0.3943400E+10 MZ
-0.2195397E+10 SUMMATION POINT
0.0000 0.0000 0.0000
Sheet 40 of 151 r ~
ENERCON r 3 SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-5314877.
FY
=
-6960080.
FZ
=
-5314877.
MX
= -0.2883052E+10 MY
=
0.3943400E+10 MZ
-0.2195397E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 15 *********************************
USE LOAD STEP 15 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
15 SUBSTEP=
1 CUMULATIVE ITERATION=
64 TIME/FREQUENCY=
15.000 TITLE= Pad, HE(1),
Casks 1 and 2, 515 Kips East (-x),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
1030000.
FY
=
534080.0 FZ
=
0.5304349E-05 MX
=
0.3813331E+09 MY
= -0.7354200E+09 MZ
-0.1310268E+08 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE ******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
-7520260.
FY
=
-6960080.
FZ
= -0.3442952E-05
Sheet 41 of 151 F
ENERCON SSERVICES, INC.
Appendix RL4 to Calculation PGE-009-CALC-003 MX
= -0.3003141E+10 MY
=
0.3383446E+10 MZ
-0.2245315E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-7520260.
FY
=
-6960080.
FZ
=
0.6077041E-03 MX
= -0.3003141E+10 MY
=
0.3383446E+10 MZ
-0.2245315E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 16 *********************************
USE LOAD STEP 16 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
16 SUBSTEP=
1 CUMULATIVE ITERATION=
68 TIME/FREQUENCY=
16.000 TITLE= Pad, HE(1),
Casks 1 and 2, 515 Kips N 45 E (Z,-X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
728320.0 FY
=
534080.0 FZ
=
-728320.0 MX
=
0.2950272E+09 MY
= -0.3714432E+09 MZ
=
0.2264640E+08 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
Sheet 42 of 151 ENERCON F 1 SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-5314877.
FY
=
-6960080.
FZ
=
5314877.
MX
= -0.3123230E+10 MY
=
0.8392721E+09 MZ
-0.2195397E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-5314878.
FY
=
-6960080.
FZ
=
5314877.
MX
= -0.3123230E+10 MY
=
0.8392721E+09 MZ
-0.2195397E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 17 *********************************
USE LOAD STEP 17 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
17 SUBSTEP=
1 CUMULATIVE ITERATION=
73
. TIME/FREQUENCY=
17.000 TITLE= Pad, HE(1),
Casks 1 to 3, 515 Kips North (Z),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.8738952E-06 FY
=
801120.0 FZ
=
-1545000.
MX
=
0.4161553E+09 MY
=
0.4202400E+09 MZ
=
0.2179046E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
Sheet 43 of 151 F
'~ENERCON F SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.1016409E-04 FY
=
-7227120.
FZ
=
8035260.
MX
= -0.3330025E+10 MY
= -0.2406260E+10 MZ
-0.2184261E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.1446143E-02 FY
=
-7227120.
FZ
=
8035260.
MX
= -0.3330025E+10 MY
= -0.2406260E+10 MZ
-0.2184261E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 18 *********************************
USE LOAD STEP 18 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
18 SUBSTEP=
1 CUMULATIVE ITERATION=
78 TIME/FREQUENCY=
18.000 TITLE= Pad, HE(l),
Casks 1 to 3, 515 Kips N 45 W (Z,X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-1092480.
FY
=
801120.0 FZ
=
-1092480.
MX
=
0.4697789E+09 MY
=
0.1114330E+10 MZ
=
0.3473635E+09
Sheet 44 of 151 ESERCON F
A SERVICES,INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE
- '*** LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
5679037.
FY
=
-7227120.
FZ
=
5679037.
MX
= -0.3297982E+10 MY
= -0.4389132E+10 MZ
-0.2107324E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
5679037.
FY
=
-7227120.
FZ
=
5679037.
MX
= -0.3297982E+10 MY
= -0.4389132E+10 MZ
-0.2107324E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 19 *********************************
USE LOAD STEP 19 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
19 SUBSTEP=
1 CUMULATIVE ITERATION=
83 TIME/FREQUENCY=
19.000 TITLE= Pad, HE(1),
Casks 1 to 3, 515 Kips West (X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-1545000.
Sheet 45 of 151 r ~
ENERCON r 1 SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 FY
=
801120.0 FZ
=
0.1073334E-05 MX
=
0.5992378E+09 MY
=
0.1155660E+10 MZ
=
0.4009871E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
8035260.
FY
=
-7227120.
FZ
=
0.1352398E-04 MX
= -0.3221046E+10 MY
= -0.3803686E+10 MZ
-0.2075281E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
8035260.
FY
=
-7227120.
FZ
= -0.1956761E-02 MX
= -0.3221046E+10 MY
= -0.3803686E+10 MZ
-0.2075281E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 20 *********************************
USE LOAD STEP 20 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
20 SUBSTEP=
1 CUMULATIVE ITERATION=
88 TIME/FREQUENCY=
20.000 TITLE= Pad, HE(1),
Casks 1 to 3, 515 Kips S 45 W (-Z,X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK
Sheet 46 of 151 r
~
ENERCON r.
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-1092480.
FY
=
801120.0 FZ
=
1092480.
MX
=
0.7286966E+09 MY
=
0.5200205E+09 MZ
=
0.3473635E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES
- FX
=
5679037.
FY
=
-7227120.
FZ
=
-5679037.
MX
= -0.3144110E+10 MY
= -0.9878493E+09 MZ
-0.2107324E+I10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
5679037.
FY
=
-7227120.
FZ
=
-5679037.
MX
= -0.3144110E+10 MY
= -0.9878493E+09 MZ
-0.2107324E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 21 *********************************
USE LOAD STEP 21 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
21 SUBSTEP=
1 CUMULATIVE ITERATION=
92 TIME/FREQUENCY=
21.000
Sheet 47 of 151 ENERCON SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 TITLE= Pad, HE(1),
Casks 1 to 3, 515 Kips South (-Z),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES
- FX
=
0.2405465E-05 FY
=
801120.0 FZ
=
1545000.
MX
=
0.7823203E+09 MY
= -0.4202400E+09 MZ
=
0.2179046E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES
- FX
=
0.1974613E-04 FY
=
-7227120.
FZ
=
-8035260.
MX
= -0.3112067E+10 MY
=
0.2406260E+10 MZ
-0.2184261E+10 SUMMATION POINT
0.0000 0.0000 0.0000 RSEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1588907E-03 FY
=
-7227120.
FZ
=
-8035260.
MX
= -0.3112067E+10 MY
=
0.2406260E+10 MZ
-0.2184261E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 22 *********************************
Sheet 48 of 151 FUml ENERCON F
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 USE LOAD STEP 22 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
22 SUBSTEP=
1 CUMULATIVE ITERATION=
96 TIME/FREQUENCY=
22.000 TITLE= Pad, HE(l),
Casks 1 to 3, 515 Kips S 45 E (-Z,-X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
1092480.
FY
=
801120.0 FZ
=
1092480.
MX
=
0.7286966E+09 MY
= -0.1114330E+10 MZ
=
0.8844576E+08 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES
- FX
=
-5679037.
FY
=
-7227120.
FZ
=
-5679037.
MX
= -0.3144110E+10 MY
=
0.4389132E+10 MZ
-0.2261197E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-5679037.
FY
=
-7227120.
FZ
=
-5679037.
MX
= -0.3144110E+10 MY
=
0.4389132E+10 MZ
= -0.2261197E+10
Sheet 49 of 151 r ~jENERCON r
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 SUMMATION POINT=
0.0000 0.0000 0.0000 LOAD CASE 23 *********************************
USE LOAD STEP 23 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
23 SUBSTEP=
1 CUMULATIVE ITERATION=
101 TIME/FREQUENCY=
23.000 TITLE= Pad, HE(l),
Casks 1 to 3, 515 Kips East (-x),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
1545000.
FY
=
801120.0 FZ
= -0.6804747E-05 MX
=
0.5992378E+09 MY
= -0.1155660E+10 MZ
=
0.3482214E+08 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-8035260.
FY
=
-7227120.
FZ
= -0.1158217E-05 MX
= -0.3221046E+10 MY
=
0.3803686E+10 MZ
-0.2293240E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-8035260.
FY
=
-7227120.
Sheet 50 of 151 l
ENERCON F
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 FZ
= -0.2711743E-03 MX
= -0.3221046E+10 MY
=
0.3803686E+10 MZ
-0.2293240E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 24 *********************************
USE LOAD STEP 24 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
24 SUBSTEP=
1 CUMULATIVE ITERATION=
108 TIME/FREQUENCY=
24.000 TITLE= Pad, HE(l),
Casks 1 to 3, 515 Kips N 45 E (Z,-X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
1092480.
FY
=
801120.0 FZ
=
-1092480.
MX
=
0.4697789E+09 MY
= -0.5200205E+09 MZ
=
0.8844576E+08 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES
- FX
=
-5679037.
FY
=
-7227120.
FZ
=
5679037.
MX
= -0.3297982E+10 MY
=
0.9878493E+09 MZ
-0.2261197E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED) SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY
Sheet 51 of 151 F l ENERCON F SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003
- LOA**
LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-5679038.
FY
=
-7227120.
FZ
=
5679037.
MX
= -0.3297982E+10 MY
=
0.9878493E+09 MZ
-0.2261197E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 25 *********************************
USE LOAD STEP 25 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
25 SUBSTEP=
1 CUMULATIVE ITERATION=
113 TIME/FREQUENCY=
25.000 TITLE= Pad, HE(1),
Casks 1 to 4, 515 Kips North (Z),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1583816E-04 FY
=
1068160.
FZ
=
-2060000.
MX
=
0.5185562E+09 MY
=
0.6303600E+09 MZ
=
0.3268570E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.2874678E-04 FY
=
-7494160.
FZ
=
8550260.
MX
= -0.3432426E+10 MY
= -0.2616380E+10 MZ
-0.2293213E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
Sheet 52 of 151 r
ENERCON r
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 1728 ELEMENTS (OF 15348 DEFINED) SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.2942764E-04 FY
=
-7494160.
FZ
=
8550260.
MX
= -0.3432426E+10 MY
= -0.2616380E+10 MZ
-0.2293213E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 26 *********************************
USE LOAD STEP 26 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
26 SUBSTEP=
1 CUMULATIVE ITERATION=
119 TIME/FREQUENCY=
26.000 TITLE= Pad, HE(l),
Casks 1 to 4, 515 Kips N 45 W (Z,X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-1456640.
FY
=
1068160.
FZ
=
-1456640.
MX
=
0.5900544E+09 MY
=
0.1485773E+10 MZ
=
0.4994688E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES
- FX
=
6043197.
FY
=
-7494160.
FZ
=
6043197.
MX
= -0.3418257E+10 MY
= -0.4760575E+10
Sheet 53 of 151 F l lENERCON FSERVICES, INC.
Appendix RL4 to Calculation PGE-009-CALC-003 MZ
-0.2259430E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2
TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
6043198.
FY
=
-7494160.
FZ
=
6043197.
MX
= -0.3418257E+10 MY
= -0.4760575E+10 MZ
-0.2259430E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 27 *********************************
USE LOAD STEP 27 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
27 SUBSTEP=
1 CUMULATIVE ITERATION=
125 TIME/FREQUENCY=
27.000 TITLE= Pad, HE(1),
Casks 1 to 4, 515 Kips West (X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-2060000.
FY
=
1068160.
FZ
=
0.9695931E-05 MX
=
0.7626662E+09 MY
=
0.1470840E+10 MZ
=
0.5709670E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES
- Sheet 54 of 151
- r.
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 FX
=
8550260.
FY
=
-7494160.
FZ
= -0.8574152E-05 MX
= -0.3384474E+10 MY
= -0.4118866E+10 MZ
-0.2245261E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
8550260.
FY
=
-7494160.
FZ
= -0.1889136E-02 MX
= -0.3384474E+10 MY
= -0.4118866E+10 MZ
-0.2245261E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 28 *********************************
USE LOAD STEP 28 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
28 SUBSTEP=
1 CUMULATIVE ITERATION=
130 TIME/FREQUENCY=
28.000 TITLE= Pad, HE(1),
Casks 1 to 4, 515 Kips S 45 W (-Z,X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *****
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-1456640.
FY
=
1068160.
FZ
=
1456640.
MX
=
0.9352781E+09 MY
=
0.5943091E+09 MZ
=
0.4994688E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
Sheet 55 of 151 run ENERCON r -
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
6043197.
FY
=
-7494160.
FZ
=
-6043197.
MX
= -0.3350691E+10 MY
= -0.1062138E+10 MZ
-0.2259430E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
6043198.
FY
=
-7494160.
FZ
=
-6043197.
MX
= -0.3350691E+10 MY
= -0.1062138E+10 MZ
-0.2259430E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 29 *
.USE LOAD STEP 29 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
29 SUBSTEP=
1 CUMULATIVE ITERATION=
134 TIME/FREQUENCY=
29.000 TITLE= Pad, HE(l),
Casks 1 to 4, 515 Kips South (-Z),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1133959E-04 FY
=
1068160.
FZ
=
2060000.
MX
=
0.1006776E+10 MY
= -0.6303600E+09 MZ
=
0.3268570E+09 SUMMATION POINT=
0.0000 0.0000 0.0000
Sheet 56 of 151 F *ENERCON F SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.4349726E-04 FY
=
-7494160.
FZ
=
-8550260.
MX
= -0.3336523E+10 MY
=
0.2616380E+10 MZ
-0.2293213E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.7684545E-05 FY
=
-7494160.
FZ
=
-8550260.
MX
= -0.3336523E+I10 MY
=
0.2616380E+10 MZ
-0.2293213E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 30 *********************************
USE LOAD STEP 30 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
30 SUBSTEP=
1 CUMULATIVE ITERATION=
144 TIME/FREQUENCY=
30.000 TITLE= Pad, HE(l),
Casks 1 to 5, 515 Kips North (Z),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.7514946E-06 FY
=
1335200.
FZ
=
-2575000.
Sheet 57 of 151 SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 MX
=
0.6754334E+09 MY
=
0.6303600E+09 MZ
=
0.3268570E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1435080E-04 FY
=
-7761200.
FZ
=
9065260.
MX
= -0.3589303E+10 MY
= -0.2616380E+10 MZ
-0.2293213E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.3242998E-03 FY
=
-7761200.
FZ
=
9065260.
MX
= -0.3589303E+10 MY
= -0.2616380E+10 MZ
-0.2293213E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 31 *********************************
USE LOAD STEP 31 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
31 SUBSTEP=
1 CUMULATIVE ITERATION=
151 TIME/FREQUENCY=
31.000 TITLE= Pad, HE(l),
Casks 1 to 5, 515 Kips N 45 W (Z,X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS
Sheet 58 of 151 r,
C
- r.
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
-1820800.
FY
=
1335200.
FZ
=
-1820800.
MX
=
0.7648061E+09 MY
=
0.1782927E+10 MZ
=
0.5426218E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
6407357.
FY
=
-7761200.
FZ
=
6407357.
MX
= -0.3593009E+10 MY
= -0.5057729E+10 MZ
-0.2302583E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
6407357.
FY
=
-7761200.
FZ
=
6407357.
MX
= -0.3593009E+10 MY
= -0.5057729E+10 MZ
-0.2302583E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 32 *********************************
USE LOAD STEP 32 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
32 SUBSTEP=
1 CUMULATIVE ITERATION=
156 TIME/FREQUENCY=
32.000 TITLE= Pad, HE(1),
Casks 1 to 5, 515 Kips West (X),
Soft Rock
Sheet 59 of 151 F '*~IENERCON FSERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-2575000.
FY
=
1335200.
FZ
=
0.3504371E-04 MX
=
0.9805709E+09 MY
=
0.1891080E+10 MZ
=
0.6319945E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
9065260.
FY
=
-7761200.
FZ
=
0.2893927E-04 MX
= -0.3602379E+10 MY
= -0.4539106E+10 MZ
-0.2306289E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
9065260.
FY
=
-7761200.
FZ
= -0.2676164E-02 MX
= -0.3602379E+10 MY
= -0.4539106E+10 MZ
-0.2306289E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 33 *********************************
USE LOAD STEP 33 SUBSTEP 0
FOR LOAD CASE 0
Sheet 60 of 151 F
~
ENERCON SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 SET COMMAND GOT LOAD STEP=
33 SUBSTEP=
1 CUMULATIVE ITERATION=
161 TIME/FREQUENCY=
33.000 TITLE= Pad, HE(1),
Casks 1 to 5, 515 Kips S 45 W (-Z,X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES
- FX
=
-1820800.
FY
=
1335200.
FZ
=
1820800.
MX
=
0.1196336E+10 MY
=
0.8914637E+09 MZ
=
0.5426218E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMP.ONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
6407357.
FY
=
-7761200.
FZ
=
-6407357.
MX
= -0.3611749E+10 MY
= -0.1359293E+10 MZ
-0.2302583E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
6407358.
FY
=
-7761200.
FZ
=
-6407357.
MX
= -0.3611749E+10 MY
= -0.1359293E+10 MZ
-0.2302583E+10 SUMMATION POINT
0.0000 0.0000 0.0000
Sheet 61 of 151 F.~ ENER CON S
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 LOAD CASE 34 *********************************
USE LOAD STEP 34 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
34 SUBSTEP=
1 CUMULATIVE ITERATION=
165 TIME/FREQUENCY=
34.000 TITLE= Pad, HE(l),
Casks 1 to 5, 515 Kips South (-Z),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1983018E-05 FY
=
1335200.
FZ
=
2575000.
MX
=
0.1285708E+10 MY
= -0.6303600E+09 MZ
=
0.3268570E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
= -0.1630182E-04 FY
=
-7761200.
FZ
=
-9065260.
MX
= -0.3615455E+10 MY
=
0.2616380E+10 MZ
-0.2293213E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1241767E-02 FY
=
-7761200.
FZ
=
-9065260.
MX
= -0.3615455E+10
Sheet 62 of 151 FSERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 MY
=
0.2616380E+10 MZ
-0.2293213E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 35 *********************************
USE LOAD STEP 35 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
35 SUBSTEP=
1 CUMULATIVE ITERATION=
169 TIME/FREQUENCY=
35.000 TITLE= Pad, HE(l),
Casks 1 to 5, 515 Kips S 45 E (-Z,-X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
1820800.
FY
=
1335200.
FZ
=
1820800.
MX
=
0.1196336E+10 MY
= -0.1782927E+10 MZ
=
0.1110922E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-6407357.
FY
=
-7761200.
FZ
=
-6407357.
MX
= -0.3611749E+10 MY
=
0.5057729E+10 MZ
-0.2283843E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
Sheet 63 of 151 F
ENERCON A SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-6407357.
FY
=
-7761200.
FZ
=
-6407357.
MX
= -0.3611749E+10 MY
=
0.5057729E+10 MZ
-0.2283843E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 36
- USE LOAD STEP 36 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
36 SUBSTEP=
1 CUMULATIVE ITERATION=
175 TIME/FREQUENCY=
36.000 TITLE= Pad, HE(1),
Casks 1 to 5, 515 Kips East (-x),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
2575000.
FY
=
1335200.
FZ
= -0.4613663E-05 MX
=
0.9805709E+09 MY
= -0.1891080E+10 MZ
=
0.2171946E+08 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-9065260.
FY
=
-7761200.
FZ
=
0.1298883E-04 MX
= -0.3602379E+10 MY
=
0.4539106E+10 MZ
-0.2280137E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
Sheet 64 of 151 SENERCON F
SERVICES, INC.
Appendix RL4 to Calculation PGE-009-CALC-003 SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-9065260.
FY
=
-7761200.
FZ
= -0.1181374E-02 MX
= -0.3602379E+10 MY
=
0.4539106E+I10 MZ
-0.2280137E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 37 *********************************
USE LOAD STEP 37 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
37 SUBSTEP=
1 CUMULATIVE ITERATION=
183 TIME/FREQUENCY=
37.000 TITLE= Pad, HE(1),
Casks 1 to 5, 515 Kips N 45 E (Z,-X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
1820800.
FY
=
1335200.
FZ
=
-1820800.
MX
=
0.7648061E+09 MY
= -0.8914637E+09 MZ
=
0.1110922E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-6407357.
FY
=
-7761200.
FZ
=
6407357.
MX
= -0.3593009E+10 MY
=
0.1359293E+10 MZ
= -0.2283843E+10
Sheet 65 of 151 F
ENERCON FSERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-6407357.
FY
=
-7761200.
FZ
=
6407357.
MX
= -0.3593009E+10 MY
=
0.1359293E+10 MZ
-0.2283843E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 38 *********************************
USE LOAD STEP 38 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
38 SUBSTEP=
1 CUMULATIVE ITERATION=
190 TIME/FREQUENCY=
38.000 TITLE= Pad, HE(1),
Casks 1 to 6, 515 Kips North (Z),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1122735E-06 FY
=
1602240.
FZ
=
-3090000.
MX
=
0.8323105E+09 MY
=
0.9455400E+09 MZ
=
0.4902854E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1336810E-04 FY
=
-8028240.
Sheet 66 of 151 F j ENERCON SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 FZ
=
9580260.
MX
= -0.3746180E+I10 MY
= -0.2931560E+10 MZ
-0.2456641E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.2585423E-05 FY
=
-8028240.
FZ
=
9580260.
MX
= -0.3746180E+10 MY
= -0.2931560E+10 MZ
-0.2456641E+I10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 39 *********************************
USE LOAD STEP 39 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
39 SUBSTEP=
1 CUMULATIVE ITERATION=
197 TIME/FREQUENCY=
39.000 TITLE= Pad, HE(1),
Casks 1 to 6, 515 Kips N 45 W (Z,X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED) SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-2184960.
FY
=
1602240.
FZ
=
-2184960.
MX
=
0.9395578E+09 MY
=
0.2302948E+10 MZ
=
0.7492032E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED) SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE
Sheet 67 of 151 F
~ENERCON A
SERVICES, INC.
Appendix RL4 to Calculation PGE-009-CALC-003 LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
6771517.
FY
=
-8028240.
FZ
=
6771517.
MX
= -0.3767761E+10 MY
= -0.5577750E+10 MZ
-0.2509164E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
6771517.
FY
=
-8028240.
FZ
=
6771517.
MX
= -0.3767761E+10 MY
= -0.5577750E+10 MZ
-0.2509164E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 40
- USE LOAD STEP 40 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
40 SUBSTEP=
1 CUMULATIVE ITERATION=
203 TIME/FREQUENCY=
40.000 TITLE= Pad, HE(l),
Casks 1 to 6, 515 Kips West (X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED) SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-3090000.
FY
=
1602240.
FZ
=
0.7267194E-05 MX
=
0.1198476E+10 MY
=
0.2311320E+10 MZ
=
0.8564504E+09 SUMMATION POINT=
0.0000 0.0000 0.0000
Sheet 68 of 151
~jENERCON F
A SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
9580260.
FY
=
-8028240.
FZ
=
0.9570563E-05 MX
= -0.3820284E+10 MY
= -0.4959346E+I10 MZ
-0.2530745E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
9580260.
FY
=
-8028240.
FZ
= -0.2004258E-02 MX
= -0.3820284E+10 MY
= -0.4959346E+10 MZ
-0.2530745E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 41 *********************************
USE LOAD STEP 41 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
41 SUBSTEP=
1 CUMULATIVE ITERATION=
208 TIME/FREQUENCY=
41.000 TITLE= Pad, HE(1),
Casks 1 to 6, 515 Kips S 45 W (-Z,X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-2184960.
FY
=
1602240.
FZ
=
2184960.
MX
=
0.1457393E+10
Sheet 69 of 151 F
~
ENERCON SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 MY
=
0.9657523E+09 MZ
=
0.7492032E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
6771517.
FY
=
-8028240.
FZ
=
-6771517.
MX
= -0.3872806E+10 MY
= -0.1433581E+10 MZ
-0.2509164E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
6771517.
FY
=
-8028240.
FZ
=
-6771517.
MX
= -0.3872806E+10 MY
= -0.1433581E+10 MZ
-0.2509164E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 42 *********************************
USE LOAD STEP 42 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
42 SUBSTEP=
1 CUMULATIVE ITERATION=
213 TIME/FREQUENCY=
42.000 TITLE= Pad, HE(1),
Casks 1 to 6, 515 Kips South (-Z),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
Sheet 70 of 151 r
3ENERCON r
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.9941150E-06 FY
=
1602240.
FZ
=
3090000.
MX
=
0.1564641E+I10 MY
= -0.9455400E+09 MZ
=
0.4902854E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.2742890E-04 FY
=
-8028240.
FZ
=
-9580260.
MX
= -0.3894387E+10 MY
=
0.2931560E+10 MZ
-0.2456641E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
0.5174761E-05 FY
=
-8028240.
FZ
=
-9580260.
MX
= -0.3894387E+10 MY
=
0.2931560E+10 MZ
-0.2456641E+10 SUMMATION POINT
0.0000 0.0000 0.0000 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
17051 NODES (OF 17051 DEFINED)
SELECTED BY NALL COMMAND.
EXIT THE ANSYS POST1 DATABASE PROCESSOR ROUTINE COMPLETED *****
CP =
126.021
Sheet 71 of 151 F
ENERCON F SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 NOTE CP=
126.021 TIME= 12:52:41 A total of 1 warnings and errors written to dcslabs7.err.
Sheet 72 of 151 ESERCON F 3 SERVICES,I'NC.
Appendix RL4 to Calculation PGE-009-CALC-003 ANSYS input file for processing reaction loads for casks 1 to 7 through 1 to 10:
/com,
/com, This routine processes load results data for the
/com, evaluation of equilibrium.
/com
/com, Soft Rock Load Step Results for Cask Load Sequence 2
/com, This is for load sequence for casks 7 through 10
/com
/output,padsoftreacseq2,out
/com
/corn
- +****
/ corn
/com
- Soft Rock Reactions****************************
/com
/file,dcslabs7 resume
/postl eall nall
/com
/com
/com LOAD CASE 1 **********************************
set,1 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS f sum esel,type,1 cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
fsum
/com
/com
/com LOAD CASE 2
- set,2 eall cmsel,s,cask
/com
/com ********
SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,1 cmsel,s,base
/com
Sheet 73 of 151 F
~
ENERCON SERVICES, INC. Appendix RL-4 to Calculation PGE-009-CALC-003
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/Com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
f sum
/com
/ com
/com LOAD CASE 3 set,3 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,l cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
fsum
/com
/com LOAD CASE 4 **********************************
set,4 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,l cmsel,s,base
/Com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2
/com cmsel,s,boundary
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS f sum
/com
/com LOAD CASE 5*
set,5 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *******
"fsum esel,type,l cmsel,s,base
/com
Sheet 74 of 151 F
'~ENERCON F
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
- fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com
/com LOAD CASE 6
- set,6 eall cmsel,s,cask
/com
/com
- SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,l cmsel,s,base
/com
/com ********
LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com ********
LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS
- fsum
/com
/com
/com *************************
LOAD CASE 7 **********************************
set,7 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
fsum
/com
/corn *************************************************************************
/com LOAD CASE 8
- set,8 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
Sheet 75 of 151 ENRCON F j SERVICES, INC.
Appendix RL4 to Calculation PGE-009-CALC-003
/com
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
- fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
fsum
/Com
/Com
/com LOAD CASE 9
- set,9 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,l cmsel,s,base
/com
/com ********
LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
fsum esel,type,2 cmsel,s,boundary
/com
/com ******** LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
fsum
/com
/com
/com *************************
LOAD CASE 10 *********************************
set,10 eall cmsel,s,cask
/Com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type, l
cmsel,s,base
/Com
/com ******** LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
fsum esel,type,2 cmsel,s,boundary
/com
/com ******** LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
fsum
/com
/COm c
/com *************************
LOAD CASE 11**
set,11 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
Sheet 76 of 151 F j ENERCON SERVICES, INC.
Appendix RL4 to Calculation PGE-009-CALC-003
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com
/com LOAD CASE 12
- set,12 eall cmsel,s,cask
/com
/com
- SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,l cmsel,s,base
/com
/com ******** LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com ********
LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS ******
fsum
/com
/com LOAD CASE 13 set,13 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
/com ********
LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
- fsum esel,type,2 cmsel,s,boundary
/com
/com ********
LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
fsum
/com
/com
/com LOAD CASE 14 *********************************
set,14 eall cmsel,s,cask
/com
/com ********
SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
Sheet 77 of 151 r'AENERCON FA SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003
/com LOADS TRANSMITTED THRRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com
/com LOAD CASE 15 *********************************
set,15 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com
/com LOAD CASE 16 set,16 eall cmsel,s,cask
/com
/com ********
SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,l cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
fsum esel,type,2 cmsel, s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS f sum
/com
/com
/com LOAD CASE 17 *********************************
set,17 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,l cmsel,s,base
/com
Sheet 78 of 151
- 1 ENERCON F
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com ********
LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com************************************************************
/com LOAD CASE 18 *********************************
set,18 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS ******
f sum esel, type, 1
- cmsel, s, base
/com
/com ******** LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
- fsum esel,type,2 cmsel,s,boundary
/com
/com ******** LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
fsum
/com
/cam
/com LOAD CASE 19
- set,19 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
/com ********
LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
f sum esel,type,2 cmsel,s,boundary
/com
/com ********
LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS f sum
/com
/com*****
/com LOAD CASE 20 set,20 eall cmsel,s,cask
/com
/com ********
SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,l cmsel,s,base
/com
Sheet 79 of 151 r'AENERCON SERVICES, INC. Appendix RL-4 to Calculation PGE-009-CALC-003
/com
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
- fsum esel,type,2 cmsel,s,boundary
/Com
/com ********
LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
fsum
/com
/Com
/com LOAD CASE 21 *********************************
set,21 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,l cmsel, s, base
/com
/com
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com ******** LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/Com
/com LOAD CASE 22 *********************************
set,22 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type, l cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
fsum esel,type,2 cmsel,s,boundary
/com
/com ********
LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com LOAD CASE 23
- set,23 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS
- fsum esel,type,l cmsel,s,base
/com
Sheet 80 of 151 ENERCON F
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE ******
fsum esel,type,2
/com cmsel,s,boundary
/com ********
LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/Com
/com LOAD CASE 24 set,24 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *****
fsum esel,type,l cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
fsum esel,type,2 cmsel,s,boundary
/com
/com ******** LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/corn *************************************************************************
/com *************************
LOAD CASE 25 *********************************
set,25 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,l cmsel,s,base
/com
/com ********
LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
fsum esel,type,2 cmsel,s,boundary
/com
/com ********
LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com
/com
- LOAD CASE 26
- set,26 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS ****
fsum esel,type,l cmsel,s,base
/com
Sheet 81 of 151 F
'~ENERCON SSERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003
/com ******** LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
fsum esel,type,2 cmsel,s,boundary
/com
/com
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com eall nall fini
/output
/exit
Sheet 82 of 151 C'*
ENERCON F
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 ANSYS output file for reaction loads for casks 1 to 7 through 1 to 10:
Soft Rock Reactions ****************************
CURRENT JOBNAME REDEFINED AS dcslabs7 RESUME ANSYS DATA FROM FILE NAME=dcslabs7.db ANSYS GLOBAL STATUS ***
TITLE = Pad, HE(1),
Casks 1 to 10, 515 Kips South (-Z),
Soft Rock ANALYSIS TYPE =
STATIC (STEADY-STATE)
NUMBER OF ELEMENT TYPES =
6 15348 ELEMENTS CURRENTLY SELECTED.
MAX ELEMENT NUMBER =
33177 17051 NODES CURRENTLY SELECTED.
MAX NODE NUMBER =
17051 259 KEYPOINTS CURRENTLY SELECTED.
MAX KEYPOINT NUMBER
=
259 250 LINES CURRENTLY SELECTED.
MAX LINE NUMBER =
396 181 AREAS CURRENTLY SELECTED.
MAX AREA NUMBER =
295 70 VOLUMES CURRENTLY SELECTED.
MAX VOL.
NUMBER =
70 25 COMPONENTS CURRENTLY DEFINED MAXIMUM LINEAR PROPERTY NUMBER
=
5 MAXIMUM REAL CONSTANT SET NUMBER
=
6 ACTIVE COORDINATE SYSTEM
=
0 (CARTESIAN)
MAXIMUM CONSTRAINT EQUATION NUMBER
=
4620 NUMBER OF SPECIFIED CONSTRAINTS
=
2193 NUMBER OF NODAL LOADS
=
1080 INITIAL JOBNAME
= dcslabs7 CURRENT JOBNAME
dcslabs7 ANSYS ENGINEERING ANALYSIS SYSTEM RELEASE 5.7 ANSYS/Structural U 00150104 VERSION=INTEL NT 09:17:29 JUN 19, 2001 CP
1.222
- Pad, HE(l),
Casks 1 to 10, 515 Kips South (-Z),
Soft Rock ANSYS RESULTS INTERPRETATION (POST1)
ENTER
/SHOW,DEVICE-NAME TO ENABLE GRAPHIC DISPLAY ENTER FINISH TO LEAVE POST1 NOTE ***
CP=
1.222 TIME= 09:17:29.
Reading results into the database (SET command) will update the current displacement and force boundary conditions in the database with the values from the results file for that load set.
Note that any subsequent solutions will use these values unless action is taken to either SAVE the current values or not overwrite them (/EXIT,NOSAVE).
Sheet 83 of 151 S
ENERCON 3
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
17051 NODES (OF 17051 DEFINED)
SELECTED BY NALL COMMAND.
LOAD CASE 1 **********************************
USE LOAD STEP 1
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
1 SUBSTEP=
1 CUMULATIVE ITERATION=
9 TIME/FREQUENCY=
1.0000 TITLE= Pad, HE(l),
Casks 1 to 7, 515 Kips North (Z),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED) SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.5621790E-05 FY
=
1869280.
FZ
=
-3605000.
MX
=
0.8802353E+09 MY
=
0.1050600E+10 MZ
=
0.5447616E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.1179353E-04 FY
=
-8295280.
FZ
=
0.1009526E+08 MX
= -0.3794105E+10 MY
= -0.3036620E+10 MZ
-0.2511118E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
Sheet 84 of 151 F
'~ENERCON SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.1022989E-02 FY
=
-8295280.
FZ
=
0.1009526E+08 MX
= -0.3794105E+10 MY
= -0.3036620E+10 MZ
-0.2511118E+I10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 2 **********************************
USE LOAD STEP
.2 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
2 SUBSTEP=
1 CUMULATIVE ITERATION=
16 TIME/FREQUENCY=
2.0000 TITLE= Pad, HE(l),
Casks 1 to 7, 515 Kips N 45 W (ZX),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-2549120.
FY
=
1869280.
FZ
=
-2549120.
MX
=
0.1005357E+10 MY
=
0.2525814E+10 MZ
=
0.8468323E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
7135677.
FY
=
-8295280.
FZ
=
7135677.
MX
= -0.3833560E+10 MY
= -0.5800616E+10 MZ
-0.2606793E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
Sheet 85 of 151 r
iENERCON F
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
7135677.
FY
=
-8295280.
FZ
=
7135677.
MX
= -0.3833560E+10 MY
= -0.5800616E+10 MZ
-0.2606793E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 3 **********************************
USE LOAD STEP 3
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
3 SUBSTEP=
1 CUMULATIVE ITERATION=
22 TIME/FREQUENCY=
3.0000 TITLE= Pad, HE(l),
Casks 1 to 7, 515 Kips West (X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-3605000.
FY
=
1869280.
FZ
=
0.2085733E-04 MX
=
0.1307428E+10 MY
=
0.2521440E+10 MZ
=
0.9719541E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1009526E+08 FY
=
-8295280.
FZ
= -0.9199044E-05 MX
= -0.3929236E+10 MY
= -0.5169466E+10 MZ
= -0.2646248E+10
ENERCON F.
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 Sheet 86 of 151 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1009526E+08 FY
=
-8295280.
FZ
= -0.2103961E-02 MX
= -0.3929236E+10 MY
= -0.5169466E+10 MZ
-0.2646248E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 4 **********************************
USE LOAD STEP 4
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
4 SUBSTEP=
1 CUMULATIVE ITERATION=
TIME/FREQUENCY=
4.0000 TITLE= Pad, HE(1),
Casks 1 to 7, 515 Kips S 45 W (-Z,X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-2549120.
FY
=
1869280.
FZ
=
2549120.
MX
=
0.1609499E+10 MY
=
0.1040041E+10 MZ
=
0.8468323E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED) SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
7135677.
FY
=
-8295280.
27
Sheet 87 of 151 SENERCON F.
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 FZ
=
-7135677.
MX
= -0.4024911E+10 MY
= -0.1507870E+10 MZ
-0.2606793E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
7135677.
FY
=
-8295280.
FZ
=
-7135677.
MX
= -0.4024911E+10 MY
= -0.1507870E+10 MZ
-0.2606793E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 5 USE LOAD STEP 5
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
5 SUBSTEP=
1 CUMULATIVE ITERATION=
31 TIME/FREQUENCY=
5.0000 TITLE= Pad, HE(l),
Casks 1 to 7, 515 Kips South (-Z),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.1443982E-05 FY
=
1869280.
FZ
=
3605000.
MX
=
0.1734620E+10 MY
= -0.1050600E+I10 MZ
=
0.5447616E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE
Sheet 88 of 151 r
jENERCON
- r. J SERVICES, I NC.
Appendix RL-4 to Calculation PGE-009-CALC-003 LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.1194444E-04 FY
=
-8295280.
FZ
= -0.1009526E+08 MX
= -0.4064367E+10 MY
=
0.3036620E+10 MZ
-0.2511118E+10 SUMMATION POINT
0.0000 0.0000 o.ooo6 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.6266482E-03 FY
=
-8295280.
FZ
= -0.1009526E+08 MX
= -0.4064367E+10 MY
=
0.3036620E+10 MZ
-0.2511118E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 6 **********************************
USE LOAD STEP 6
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
6 SUBSTEP=
1 CUMULATIVE ITERATION=
38 TIME/FREQUENCY=
6.0000 TITLE= Pad, HE(l),
Casks 1 to 7, 515 Kips S 45 E (-Z,-X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
2549120.
FY
=
1869280.
FZ
=
2549120.
MX
=
0.1609499E+10 MY
= -0.2525814E+10 MZ
=
0.2426909E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
Sheet 89 of 151 F l ENERCON SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES
- FX
=
-7135677.
FY
=
-8295280.
FZ
=
-7135677.
MX
= -0.4024911E+10 MY
=
0.5800616E+10 MZ
-0.2415442E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED) SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-7135678.
FY
=
-8295280.
FZ
=
-7135677.
MX
= -0.4024911E+10 MY
=
0.5800616E+10 MZ
-0.2415442E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 7 **********************************
USE LOAD STEP 7
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
7 SUBSTEP=
1 CUMULATIVE ITERATION=
46 TIME/FREQUENCY=
7.0000 TITLE= Pad, HE(l),
Casks 1 to 7, 515 Kips East (-x),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
3605000.
FY
=
1869280.
FZ
= -0.1290711E-04 MX
=
0.1307428E+10 MY
= -0.2521440E+10
Sheet 90 of 151 F
'~ENERCON SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 MZ
=
0.1175691E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.1009526E+08 FY
=
-8295280.
FZ
= -0.3556770E-04 MX
= -0.3929236E+10 MY
=
0.5169466E+10 MZ
-0.2375987E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.1009526E+08 FY
=
-8295280.
FZ
= -0.1595002E-02 MX
= -0.3929236E+10 MY
=
0.5169466E+10 MZ
-0.2375987E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 8 **********************************
USE LOAD STEP 8
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
8 SUBSTEP=
1 CUMULATIVE ITERATION=
55 TIME/FREQUENCY=
8.0000 TITLE= Pad, HE(l),
Casks 1 to 7, 515 Kips N 45 E (Z,-X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES
Sheet 91 of 151 rENERCON SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 FX
=
2549120.
FY
=
1869280.
FZ
=
-2549120.
MX
=
0.1005357E+10 MY
= -0.1040041E+10 MZ
=
0.2426909E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-7135677.
FY
=
-8295280.
FZ
=
7135677.
MX
= -0.3833560E+I10 MY
=
0.1507870E+10 MZ
= -0.2415442E+10 SUMMATION POINT=.
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-7135678.
FY
=
-8295280.
FZ
=
7135677.
MX
= -0.3833560E+I10 MY
=
0.1507870E+10 MZ
-0.2415442E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 9 **********************************
USE LOAD STEP 9
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
9 SUBSTEP=
1 CUMULATIVE ITERATION=
62 TIME/FREQUENCY=
9.0000 TITLE= Pad, HE(1),
Casks 1 to 8, 515 Kips North (Z),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
Sheet 92 of 151 F
'~ENERCON F SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1088402E-04 FY
=
2136320.
FZ
=
-4120000.
MX
=
0.9281602E+09 MY
=
0.1260720E+10 MZ
=
0.6537139E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.1485564E-04 FY
=
-8562320.
FZ
=
0.1061026E+08 MX
= -0.3842030E+10 MY
= -0.3246740E+10 MZ
-0.2620070E+I10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.8980486E-05 FY
=
-8562320.
FZ
=
0.1061026E+08 MX
= -0.3842030E+10 MY
= -0.3246740E+10 MZ
-0.2620070E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 10 *********************************
USE LOAD STEP 10 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
10 SUBSTEP=
1 CUMULATIVE ITERATION=
69
Sheet 93 of 151 E
ENERCON F A SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 TIME/FREQUENCY=
10.000 TITLE= Pad, HE(1),
Casks 1 to 8, 515 Kips N 45 W (Z,X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-2913280.
FY
=
2136320.
FZ
=
-2913280.
MX
=
0.1071156E+10 MY
=
0.2822968E+10 MZ
=
0.9989376E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
7499837.
FY
=
-8562320.
FZ
=
7499837.
MX
= -0.3899360E+10 MY
= -0.6097770E+I10 MZ
-0.2758899E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS
"***** SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
7499838.
FY
=
-8562320.
FZ
=
7499837.
MX
= -0.3899360E+10 MY
= -0.6097770E+10 MZ
-0.2758899E+10 SUMMATION POINT
0.0000 0.0000 0.0000
- L LOAD CASE i1 *********************************
Sheet 94 of 151 F
~
ENERCON SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 USE LOAD STEP 11 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
11 SUBSTEP=
1 CUMULATIVE ITERATION=
75 TIME/FREQUENCY=
11.000 TITLE= Pad, HE(l),
Casks 1 to 8, 515 Kips West (X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-4120000.
FY
=
2136320.
FZ
=
0.3337948E-04 MX
=
0.1416380E+10 MY
=
0.2731560E+I10 MZ
=
0.1141934E+10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1061026E+08 FY
=
-8562320.
FZ
=
0.1314772E-04 MX
= -0.4038188E+10 MY
= -0.5379586E+10 MZ
-0.2816228E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES
- FX
=
0.1061026E+08 FY
=
-8562320.
FZ
= -0.1673062E-02 MX
= -0.4038188E+I10 MY
= -0.5379586E+10 MZ
= -0.2816228E+I10
Sheet 95 of 151 r
-JENERCON S
A SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 SUMMATION POINT=
0.0000 0.0000 0.0000 LOAD CASE 12 *********************************
USE LOAD STEP 12 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
12 SUBSTEP=
1 CUMULATIVE ITERATION=
80 TIME/FREQUENCY=
12.000 TITLE= Pad, HE(1),
Casks 1 to 8, 515 Kips S 45 W (-Z,X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK
- SUM OF LOADS APPLIED TO CASKS Vr****
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
-2913280.
FY
=
2136320.
FZ
=
2913280.
MX
=
0.1761604E+10 MY
=
0.1040041E+10 MZ
=
0.9989376E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED) SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
- SUMMATION OF TOTAL
-FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
7499837.
FY
=
-8562320.
FZ
=
-7499837.
MX
= -0.4177017E+10 MY
= -0.1507870E+10 MZ
-0.2758899E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
7499838.
Sheet 96 of 151 F
'~ENERCON F SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 FY
=
-8562320.
FZ
=
-7499837.
MX
= -0.4177017E+10 MY
= -0.1507870E+10 MZ
-0.2758899E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 13 *********************************
USE LOAD STEP 13 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
13 SUBSTEP=
1 CUMULATIVE ITERATION=
84 TIME/FREQUENCY=
13.000 TITLE= Pad, HE(1),
Casks 1 to 8, 515 Kips South (-Z),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1246286E-05 FY
=
2136320.
FZ
=
4120000.
MX
=
0.1904600E+10 MY
= -0.1260720E+10 MZ
=
0.6537139E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.5025056E-04 FY
=
-8562320.
FZ
= -0.1061026E+08 MX
= -0.4234346E+10 MY
=
0.3246740E+10 MZ
-0.2620070E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY
Sheet 97 of 151 C'i jENERCON F,
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1214107E-04 FY
=
-8562320.
FZ
= -0.1061026E+08 MX
= -0.4234346E+10 MY
=
0.3246740E+10 MZ
-0.2620070E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 14 *********************************
USE LOAD STEP 14 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
14 SUBSTEP=
1 CUMULATIVE ITERATION=
94 TIME/FREQUENCY=
14.000 TITLE= Pad, HE(l),
Casks I to 9, 515 Kips North (Z),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
= -0.3853758E-05 FY
=
2403360.
FZ
=
-4635000.
MX
=
0.1030561E+10 MY
=
0.1260720E+10 MZ
=
0.6537139E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.9745712E-05 FY
=
-8829360.
FZ
=
0.1112526E+08 MX
= -0.3944431E+10 MY
= -0.3246740E+10 MZ
-0.2620070E+10 SUMMATION POINT
0.0000 0.0000 0.0000
Sheet 98 of 151 r 'j ERCON F a SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.1856031E-02 FY
=
-8829360.
FZ
=
0.1112526E+08 MX
= -0.3944431E+10 MY
= -0.3246740E+10 MZ
-0.2620070E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 15 *********************************
USE LOAD STEP 15 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
15 SUBSTEP=
1 CUMULATIVE ITERATION=
102 TIME/FREQUENCY=
15.000 TITLE= Pad, HE(l),
Casks 1 to 9, 515 Kips N 45 W (ZX),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-3277440.
FY
=
2403360.
FZ
=
-3277440.
MX
=
0.1191432E+10 MY
=
0.3045834E+10 MZ
=
0.1042091E+10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED) SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES
- FX
=
7863997.
FY
=
-8829360.
FZ
=
7863997.
MX
= -0.4019635E+10
Sheet 99 of 151 F HNENERCON A SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 MY
= -0.6320636E+10 MZ
-0.2802051E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
7863997.
FY
=
-8829360.
FZ
=
7863997.
MX
= -0.4019635E+10 MY
= -0.6320636E+10 MZ
-0.2802051E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 16 *********************************
USE LOAD STEP 16 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
16 SUBSTEP=
1 CUMULATIVE ITERATION=
109 TIME/FREQUENCY=
16.000 TITLE= Pad, HE(l),
Casks 1 to 9, 515 Kips West (X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-4635000.
FY
=
2403360.
FZ
=
0.1003488E-04 MX
=
0.1579809E+10 MY
=
0.3046740E+10 MZ
=
0.1202961E+10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
Sheet 100 of 151 r
C r.
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1112526E+08 FY
=
-8829360.
FZ
=
0.8847758E-05 MX
= -0.4201617E+10 MY
= -0.5694766E+10 MZ
-0.2877256E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1112526E+08 FY
=
-8829360.
FZ
= -0.4772679E-02 MX
= -0.4201617E+10 MY
= -0.5694766E+10 MZ
-0.2877256E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 17 *********************************
USE LOAD STEP 17 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
17 SUBSTEP=
1 CUMULATIVE ITERATION=
114 TIME/FREQUENCY=
17.000 TITLE= Pad, HE(l),
Casks 1 to 9, 515 Kips S 45 W (-Z,X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-3277440.
FY
=
2403360.
FZ
=
3277440.
MX
=
0.1968185E+10 MY
=
0.1262907E+10 MZ
=
0.1042091E+10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
Sheet 101 of 151 F 3 ENERCON I
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
7863997.
FY
=
-8829360.
FZ
=
-7863997.
MX
= -0.4383598E+10 MY
= -0.1730736E+10 MZ
-0.2802051E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
7863998.
FY
=
-8829360.
FZ
=
-7863997.
MX
= -0.4383598E+10 MY
= -0.1730736E+10 MZ
-0.2802051E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 18 *********************************
USE LOAD STEP 18 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
18 SUBSTEP=
1 CUMULATIVE ITERATION=
119 TIME/FREQUENCY=
18.000 TITLE= Pad, HE(1),
Casks 1 to 9, 515 Kips South (-Z),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.2623387E-05 FY
=
2403360.
FZ
=
4635000.
MX
=
0.2129056E+10 MY
= -0.1260720E+10 MZ
=
0.6537139E+09
Sheet 102 of 151 ENERCON SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1635327E-04 FY
=
-8829360.
FZ
= -0.1112526E+08 MX
= -0.4458802E+10 MY
=
0.3246740E+10 MZ
-0.2620070E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
0.1271337E-02 FY
=
-8829360.
FZ
= -0.1112526E+08 MX
= -0.4458802E+10 MY
=
0.3246740E+10 MZ
-0.2620070E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 19 *********************************
USE LOAD STEP 19 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
19 SUBSTEP=
1 CUMULATIVE ITERATION=
126 TIME/FREQUENCY=
19.000 TITLE= Pad, HE(1),
Casks 1 to 9, 515 Kips S 45 E (-Z,-X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
3277440.
FY
=
2403360.
Sheet 103 of 151 IENERCON SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 FZ
=
3277440.
MX
=
0.1968185E+10 MY
= -0.3045834E+10 MZ
=
0.2653373E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-7863997.
FY
=
-8829360.
FZ
=
-7863997.
MX
= -0.4383598E+10 MY
=
0.6320636E+10 MZ
-0.2438088E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-7863998.
FY
=
-8829360.
FZ
=
-7863997.
MX
= -0.4383598E+10 MY
=
0.6320636E+10 MZ
-0.2438088E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 20 *********************************
USE LOAD STEP 20 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
20 SUBSTEP=
1 CUMULATIVE ITERATION=
133 TIME/FREQUENCY=
20.000 TITLE= Pad, HE(l),
Casks 1 to 9, 515 Kips East (-x),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK
Sheet 104 of 151 r ~
ENERCON r
A SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003
- SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
4635000.
FY
=
2403360.
FZ
= -0.5047132E-05 MX
=
0.1579809E+10 MY
= -0.3046740E+10 MZ
=
0.1044664E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.1112526E+08 FY
=
-8829360.
FZ
=
0.8746337E-04 MX
= -0.4201617E+10 MY
=
0.5694766E+10 MZ
-0.2362884E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.1112526E+08 FY
=
-8829360.
FZ
=
0.5153256E-03 MX
= -0.4201617E+10 MY
=
0.5694766E+10 MZ
-0.2362884E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 21 *********************************
USE LOAD STEP 21 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
21 SUBSTEP=
1 CUMULATIVE ITERATION=
143 TIME/FREQUENCY=
21.000 TITLE= Pad, HE(i),
Casks 1 to 9, 515 Kips N 45 E (Z,-X),
Soft Rock
Sheet 105 of 151 F '! ENERCON SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
3277440.
FY
=
2403360.
FZ
=
-3277440.
MX
=
0.1191432E+10 MY
= -0.1262907E+10 MZ
=
0.2653373E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-7863997.
FY
=
-8829360.
FZ
=
7863997.
MX
= -0.4019635E+10 MY
=
0.1730736E+10 MZ
-0.2438088E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-7863998.
FY
=
-8829360.
FZ
=
7863997.
MX
= -0.4019635E+10 MY
=
0.1730736E+10 MZ
-0.2438088E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 22 *********************************
Sheet 106 of 151 EERCON F A SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 USE LOAD STEP 22 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
22 SUBSTEP=
1 CUMULATIVE ITERATION=
150 TIME/FREQUENCY=
22.000 TITLE= Pad, HE(l),
Casks 1 to 10, 515 Kips North (Z),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1946680E-04 FY
=
2670400.
FZ
=
-5150000.
MX
=
0.1132962E+10 MY
=
0.1575900E+10 MZ
=
0.8171424E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1001725E-04 FY
=
-9096400.
FZ
=
0.1164026E+08 MX
= -0.4046832E+10 MY
= -0.3561920E+10 MZ
-0.2783498E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.3276465E-05 FY
=
-9096400.
FZ
=
0.1164026E+08 MX
= -0.4046832E+10 MY
= -0.3561920E+10 MZ
-0.2783498E+10 SUMMATION POINT
0.0000 0.0000 0.0000
Sheet 107 of 151 F *IENERCON SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 LOAD CASE 23 USE LOAD STEP 23 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
23 SUBSTEP=
1 CUMULATIVE ITERATION=
158 TIME/FREQUENCY=
23.000 TITLE= Pad, HE(1),
Casks 1 to 10, 515 Kips N 45 W (Z,X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-3641600.
FY
=
2670400.
FZ
=
-3641600.
MX
=
0.1311708E+10 MY
=
0.3491566E+10 MZ
=
0.1248672E+10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES
. FX
=
8228157.
FY
=
-9096400.
FZ
=
8228157.
MX
= -0.4139911E+10 MY
= -0.6766368E+10 MZ
-0.3008633E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
8228157.
FY
=
-9096400.
FZ
=
8228157.
Sheet 108 of 151 r ~JENERCON r.A SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 MX
= -0.4139911E+10 MY
= -0.6766368E+10 MZ
-0.3008633E+I10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 24 *********************************
USE LOAD STEP 24 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
24 SUBSTEP=
1 CUMULATIVE ITERATION=
165 TIME/FREQUENCY=
24.000 TITLE= Pad, HE(l),
Casks 1 to 10, 515 Kips West (X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-5150000.
FY
=
2670400.
FZ
=
0.1063272E-04 MX
=
0.1743237E+10 MY
=
0.3361920E+10 MZ
=
0.1427417E+10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1164026E+08 FY
=
-9096400.
FZ
= -0.3396336E-04 MX
= -0.4365045E+10 MY
= -0.6009946E+10 MZ
-0.3101712E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS
Sheet 109 of 151 F
~
ENERCON SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1164026E+08 FY
=
-9096400.
FZ
= -0.2576979E-02 MX
= -0.4365045E+10 MY
= -0.6009946E+10 MZ
-0.3101712E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 25 *********************************
USE LOAD STEP 25 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
25 SUBSTEP=
1 CUMULATIVE ITERATION=
170 TIME/FREQUENCY=
25.000 TITLE= Pad, HE(l),
Casks 1 to 10, 515 Kips S 45 W (-Z,X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-3641600.
FY
=
2670400.
FZ
=
3641600.
MX
=
0.2174767E+10 MY
=
0.1262907E+10 MZ
=
0.1248672E+10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
8228157.
FY
=
-9096400.
FZ
=
-8228157.
MX
= -0.4590180E+10 MY
= -0.1730736E+10 MZ
-0.3008633E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
Sheet 110 of 151 r.1 SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
8228157.
FY
=
-9096400.
FZ
=
-8228157.
MX
= -0.4590180E+I0 MY
= -0.1730736E+10 MZ
= -0.3008633E+10 SUMMATION POINT=.0.0000 0.0000 0.0000 LOAD CASE 26 *********************************
USE LOAD STEP 26 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
26 SUBSTEP=
1 CUMULATIVE ITERATION=
175 TIME/FREQUENCY=
26.000 TITLE= Pad, HE(1),
Casks 1 to 10, 515 Kips South (-Z),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.5976699E-06 FY
=
2670400.
FZ
=
5150000.
. MX
=
0.2353512E+10 MY
= -0.1575900E+10 MZ
=
0.8171424E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
0.8624582E-05 FY
=
-9096400.
FZ
= -0.1164026E+08 MX
= -0.4683258E+I10 MY
=
0.3561920E+10 MZ
= -0.2783498E+10
Sheet 111 of 151 F *ENERCON SERVICES, INC.
Appendix RL4 to Calculation PGE-009-CALC-003 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.2333496E-05 FY
=
-9096400.
FZ
= -0.1164026E+08 MX
= -0.4683258E+10 MY
=
0.3561920E+10 MZ
-0.2783498E+10 SUMMATION POINT
0.0000 0.0000 0.0000 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
17051 NODES (OF 17051 DEFINED)
SELECTED BY NALL COMMAND.
EXIT THE ANSYS POST1 DATABASE PROCESSOR ROUTINE COMPLETED *****
=
78.323 NOTE ***
CP=
78.323 TIME= 09:19:10 A total of 1 warnings and errors written to dcslabs7.err.
Sheet 112 of 151 ESERCON F A SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 ANSYS input file for processing reaction loads for casks 1 to 11 through I to 14:
/com,
/com, This routine processes load results data for the
/com, evaluation of equilibrium.
/com
/com, Soft Rock Load Step Results for Cask Load Sequence 2
/com, This is for load sequence for casks 11 through 14
/comr
/output,padsoftreacseq3,out
/com
/ corn *****************************************
/corn
/com *****************
Soft Rock Reactions *
/com
/file,dcslabs7 resume
/postl eall nall
/com
/com LOAD CASE 1 **********************************
set,1 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,1 cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *****
fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *****
fsum
/com
/ corn *************************************************************************
/com LOAD CASE 2
- set,2 eall cmsel,s,cask
/com
/com ********
SUM OF LOADS APPLIED TO CASKS
- fsum esel,type,1 cmsel,s,base
/com
Sheet 113 of 151 ENERCON F A SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *****
fsum
/com
/com*********************************
/com LOAD CASE 3
- set,3 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
fsum
/com
/com LOAD CASE 4
- set,4 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,l cmsel,s,base
/com
/com ********
LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2
/com cmsel,s,boundary
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *****
fsum
/com
/com
/com LOAD CASE 5
- set,5 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *****
f sum esel, type, 1 cmsel,s,base
/com
NRCON Sheet 114 of 151 SSERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE f sum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com *************************
LOAD CASE 6 **********************************
set,6 eall cmsel,s,cask
/Com
/com ********
SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
- fsum esel,type,2 cmsel,s,boundary
/com
/com ********
LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS
- f sum
/com
/com LOAD CASE 7
- set,7 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,l cmsel,s,base
/com
/com ********
LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com
/com LOAD CASE 8
- set,8 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,l cmsel,s,base
/com
Sheet 115 of 151 ENERCON F
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003
/Com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/oom
/com LOAD CASE 9 set, 9 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
/com ********
LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
fsum esel,type,2 cmsel,s,boundary
/com
/com ********
LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/oom
/com LOAD CASE 10 set,10 eall cmsel,s,cask
/com
/com ********
SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com
/com LOAD CASE 11**
set,11 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
Sheet 116 of 151 N ERCON F A SERVICES, INC.
Appendix RL4 to Calculation PGE-009-CALC-003
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/corn *************************************************************************
/com LOAD CASE 12
- set,12 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *****
fsum esel,type,l cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
fsum
/com
/com LOAD CASE 13 set,13 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,l cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com LOAD CASE 14 *********************************
set,14 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
Sheet 117 of 151 E
ENERCON SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003
/com
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel, type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com**************************************
/com LOAD CASE 15 *********************************
set,15 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,l
- cmsel,s,base
/com
/com
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
fsum
/com
/com***************************
/com LOAD CASE 16
- set,16 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
/com
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/Com
/com
/com LOAD CASE 17 set,17 eall cmsel,s,cask
/com
/com ********
SUM OF LOADS APPLIED TO CASKS fsum esel, type, 1 cmsel,s,base
/com
Sheet 118 of 151 r
'j*
ENERCON
- r.
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003
/com
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com
/com *************************
LOAD CASE 18 set,18 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
/com ********
LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
- fsum esel,type,2 cmsel,s,boundary
/com
/com
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
fsum
/com
/COrn
/com LOAD CASE 19 *********************************
set,19 eall cmsel,s,cask
/Con
/com SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,l cmsel,s,base
/Com
/com
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
- fsum esel,type,2 cmsel,s,boundary
/com
/com
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *****
fsum
/com
/ corn *************************************************************************
/com LOAD CASE 20 *********************************
set,20 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
Sheet 119 of 151 F
- ENERCON SSERVICES, INC.
Appendix RL4 to Calculation PGE-009-CALC-003
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com
- LOAD CASE 21*****************
set,21 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,l cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/Com
/comr
/com LOAD CASE 22 set,22 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,l cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
fsum
/com
/com
/com LOAD CASE 23
- set,23 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
Sheet 120 of 151 ENERCON F jSERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
- fsum esel,type,2
/com cmsel,s,boundary
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com**************
/Com LOAD CASE 24 *********************************
set,24 eall cmsel,s,cask
/Com
/com SUM OF LOADS APPLIED TO CASKS ******
fsum esel,type,l cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *****
fsum
/com
/com
/com LOAD CASE 25 *********************************
set,25 eall cmsel,s,cask
/com
/com *******t SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type, l cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com
/com LOAD CASE 26 *********************************
set,26 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS
- fsum esel,type,l cmsel,s,base
/com
Sheet 121 of 151 SERVICES, INC.
Appendix RL4 to Calculation PGE-009-CALC-003
/com
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com eall nall fini
/output
/exit
Sheet 122 of 151 r 'jENERCON
- r.
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 ANSYS output file for reaction loads for casks 1 to 11 through 1 to 14:
Soft Rock Reactions ****************************
CURRENT JOBNAME REDEFINED AS dcslabs7 RESUME ANSYS DATA FROM FILE NAME=dcslabs7.db ANSYS GLOBAL STATUS ***
TITLE = Pad, HE(1),
Casks 1 to 11, 515 Kips North (Z),
Soft Rock ANALYSIS TYPE =
STATIC (STEADY-STATE)
NUMBER OF ELEMENT TYPES =
6 9056 ELEMENTS CURRENTLY SELECTED.
MAX ELEMENT NUMBER
=
33177 11550 NODES CURRENTLY SELECTED.
MAX NODE NUMBER =
17051 259 KEYPOINTS CURRENTLY SELECTED.
MAX KEYPOINT NUMBER
=
259 250 LINES CURRENTLY SELECTED.
MAX LINE NUMBER =
396 181 AREAS CURRENTLY SELECTED.
MAX AREA NUMBER =
295 70 VOLUMES CURRENTLY SELECTED.
MAX VOL.
NUMBER =
70 25 COMPONENTS CURRENTLY DEFINED MAXIMUM LINEAR PROPERTY NUMBER
=
5 MAXIMUM REAL CONSTANT SET NUMBER
=
6 ACTIVE COORDINATE SYSTEM
=
0 (CARTESIAN)
MAXIMUM CONSTRAINT EQUATION NUMBER
=
4620 NUMBER OF SPECIFIED CONSTRAINTS
=
2193 NUMBER OF NODAL LOADS
=
2268 INITIAL JOBNAME
dcslabs7 CURRENT JOBNAME = dcslabs7 ANSYS ENGINEERING ANALYSIS SYSTEM RELEASE 5.7 ANSYS/Structural U 00150104 VERSION=INTEL NT 16:30:36 JUN 20, 2001 CP
2.774 Pad, HE(1),
Casks 1 to 11, 515 Kips North (Z),
Soft Rock ANSYS RESULTS INTERPRETATION (POST1)
ENTER
/SHOW,DEVICE-NAME TO ENABLE GRAPHIC DISPLAY ENTER FINISH TO LEAVE POST1 NOTE CP=
2.774 TIME= 16:30:36 Reading results into the database (SET command) will update the current displacement and force boundary conditions in the database with the values from the results file for that load set.
Note that any subsequent solutions will use these values unless action is taken to
Sheet 123 of 151 r
ENERCON
- r.
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 either SAVE the current values or not overwrite them (/EXIT,NOSAVE).
15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
17051 NODES (OF 17051 DEFINED)
SELECTED BY NALL COMMAND.
LOAD CASE 1 **********************************
USE LOAD STEP 1
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
1 SUBSTEP=
1 CUMULATIVE ITERATION=
11 TIME/FREQUENCY=
1.0000 TITLE= Pad, HE(l),
Casks 1 to 11, 515 Kips North (Z),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED) SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.5038988E-05 FY
=
2937440.
FZ
=
-5665000.
MX
=
0.1126411E+10 MY
=
0.1680960E+10 MZ
=
0.8716186E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED) SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.5348968E-04 FY
=
-9363440.
FZ
=
0.1215526E+08 MX
= -0.4040280E+10 MY
= -0.3666980E+10 MZ
-0.2837975E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED) SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
Sheet 124 of 151 F
J ENERCON SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 tt***
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES
- FX
= -0.6567931E-03 FY
=
-9363440.
FZ
=
0.1215526E+08 MX
= -0.4040280E+10 MY
= -0.3666980E+10 MZ
-0.2837975E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 2 **********************************
USE LOAD STEP 2
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
2 SUBSTEP=
1 CUMULATIVE ITERATION=
20 TIME/FREQUENCY=
2.0000 TITLE= Pad, HE(l),
Casks 1 to 11, 515 Kips N 45 W (Z,X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED) SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-4005760.
FY
=
2937440.
FZ
=
-4005760.
MX
=
0.1323031E+10 MY
=
0.3640143E+10 MZ
=
0.1346301E+10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
8592317.
FY
=
-9363440.
FZ
=
8592317.
MX
= -0.4151234E+10 MY
= -0.6914945E+10 MZ
-0.3106262E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
Sheet 125 of 151 F
- ENERCON FSERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
8592317.
FY
=
-9363440.
FZ
=
8592317.
MX
= -0.4151234E+10 MY
= -0.6914945E+10 MZ
-0.3106262E+10 SUMMATION POINT
.0.0000 0.0000 0.0000 LOAD CASE 3 USE LOAD STEP 3
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
3 SUBSTEP=
1 CUMULATIVE ITERATION=
27 TIME/FREQUENCY=
3.0000 TITLE= Pad, HE(1),
Casks 1 to 11, 515 Kips West (X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
-5665000.
FY
=
2937440.
FZ
=
0.1156800E-04
.MX
=
0.1797713E+10 MY
=
0.3466980E+10 MZ
=
0.1542921E+10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1215526E+08 FY
=
-9363440.
FZ
=
0.1824518E-05 MX
= -0.4419521E+10 MY
= -0.6115006E+10 MZ
= -0.3217215E+10
Sheet 126 of 151 SERVCOS NC F IA SERVICES,INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1215526E+08 FY
=
-9363440.
FZ
= -0.2625384E-02 MX
= -0.4419521E+10 MY
= -0.6115006E+10 MZ
-0.3217215E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 4 **********************************
USE LOAD STEP 4
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
4 SUBSTEP=
1 CUMULATIVE ITERATION=
33 TIME/FREQUENCY=
4.0000 TITLE= Pad, HE(l),
Casks 1 to 11, 515 Kips S 45 W (-Z,X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
-4005760.
FY
=
2937440.
FZ
=
4005760.
MX
=
0.2272396E+I10 MY
=
0.1262907E+10 MZ
=
0.1346301E+10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
8592317.
Sheet 127 of 151 ENERCON F J SERVICES, INC.
Appendix RL4 to Calculation PGE-009-CALC-003 FY
=
-9363440.
FZ
=
-8592317.
MX
= -0.4687809E+10 MY
= -0.1730736E+10 MZ
-0.3106262E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
8592317.
FY
=
-9363440.
FZ
=
-8592317.
MX
= -0.4687809E+10 MY
= -0.1730736E+10 MZ
-0.3106262E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 5 **********************************
USE LOAD STEP 5
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
5 SUBSTEP=
1 CUMULATIVE ITERATION=
38 TIME/FREQUENCY=
5.0000 TITLE= Pad, HE(1),
Casks 1 to 11, 515 Kips South (-Z),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1094125E-04 FY
=
2937440.
FZ
=
5665000.
MX
=
0.2469016E+10 MY
= -0.1680960E+10 MZ
=
0.8716186E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE
Sheet 128 of 151 r EJ RCON SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.2032347E-04 FY
=
-9363440.
FZ
= -0.1215526E+08 MX
= -0.4798762E+10 MY
=
0.3666980E+I10 MZ
-0.2837975E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.1006073E-02 FY
=
-9363440.
FZ
= -0.1215526E+08 MX
= -0.4798762E+10 MY
=
0.3666980E+10 MZ
-0.2837975E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 6 **********************************
USE LOAD STEP 6
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
6 SUBSTEP=
1 CUMULATIVE ITERATION=
46 TIME/FREQUENCY=
6.0000 TITLE= Pad, HE(l),
Casks 1 to 11, 515 Kips S 45 E (-Z,-X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
4005760.
FY
=
2937440.
FZ
=
4005760.
MX
=
0.2272396E+10 MY
= -0.3640143E+10 MZ
=
0.3969360E+09 SUMMATION POINT=
0.0000 0.0000 0.0000
Sheet 129 of 151 F l ENERCON SSERVICES, INC. Appendix RL4 to Calculation PGE-009-CALC-003 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-8592317.
FY
=
-9363440.
FZ
=
-8592317.
MX
= -0.4687809E+10 MY
=
0.6914945E+10 MZ
-0.2569687E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
-8592318.
FY
=
-9363440.
FZ
=
-8592317.
MX
= -0.4687809E+10 MY
=
0.6914945E+10 MZ
-0.2569687E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 7 **********************************
USE LOAD STEP 7
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
7 SUBSTEP=
1 CUMULATIVE ITERATION=
53 TIME/FREQUENCY=
7.0000 TITLE= Pad, HE(1),
Casks 1 to 11, 515 Kips East (-x),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
5665000.
FY
=
2937440.
FZ
= -0.2925970E-04 MX
=
0.1797713E+10
NRCON Sheet 130 of 151 SERVICES, INC.
Appendix RL4 to Calculation PGE-009-CALC-003 MY
= -0.3466980E+10 MZ
=
0.2003161E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.1215526E+08 FY
=
-9363440.
FZ
= -0.4036787E-05 MX
= -0.4419521E+10 MY
=
0.6115006E+10 MZ
-0.2458734E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.1215526E+08 FY
=
-9363440.
FZ
= -0.2493784E-02 MX
= -0.4419521E+10 MY
=
0.6115006E+10 MZ
-0.2458734E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 8 **********************************
USE LOAD STEP 8
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
8 SUBSTEP=
1 CUMULATIVE ITERATION=
63 TIME/FREQUENCY=
8.0000 TITLE= Pad, HE(1),
Casks 1 to 11, 515 Kips N 45 E (Z,-X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED) SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS
Sheet 131 of 151 F
- ENERCON FSERVICES, INC.
Appendix RL4 to Calculation PGE-009-CALC-003 SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
4005760.
FY
=
2937440.
FZ
=
-4005760.
MX
=
0.1323031E+10 MY
= -0.1262907E+10 MZ
=
0.3969360E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-8592317.
FY
=
-9363440.
FZ
=
8592317.
MX
= -0.4151234E+10 MY
=
0.1730736E+10 MZ
-0.2569687E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-8592318.
FY
=
-9363440.
FZ
=
8592317.
MX
= -0.4151234E+10 MY
=
0.1730736E+10 MZ
-0.2569687E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 9
- USE LOAD STEP 9
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
9 SUBSTEP=
1 CUMULATIVE ITERATION=
71 TIME/FREQUENCY=
9.0000 TITLE= Pad, HE(l),
Casks 1 to 12, 515 Kips North (Z),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
Sheet 132 of 151 F *ENERCON F
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1910777E-05 FY
=
3204480.
FZ
=
-6180000.
MX
=
0.1119859E+I10 MY
=
0.1891080E+10 MZ
=
0.9805709E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.1338014E-05 FY
=
-9630480.
FZ
=
0.1267026E+08 MX
= -0.4033729E+10 MY
= -0.3877100E+10 MZ
-0.2946927E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.4630728E-05 FY
=
-9630480.
FZ
=
0.1267026E+08 MX
= -0.4033729E+10 MY
= -0.3877100E+10 MZ
-0.2946927E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 10 *********************************
USE LOAD STEP 10 SUBSTEP 0
FOR LOAD CASE 0
Sheet 133 of 151 F *ENERCON SERVICES, INC. Appendix RL-4 to Calculation PGE-009-CALC-003 SET COMMAND GOT LOAD STEP=
10 SUBSTEP=
1 CUMULATIVE ITERATION=
80 TIME/FREQUENCY=
10.000 TITLE= Pad, HE(1),
Casks 1 to 12, 515 Kips N 45 W (Z,X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-4369920.
FY
=
3204480.
FZ
=
-4369920.
MX
=
0.1334354Ei-10 MY
=
0.3863009E+10 MZ
=
0.1498406E+10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
8956477.
FY
=
-9630480.
FZ
=
8956477.
MX
= -0.4162557E+10 MY
= -0.7137811E+10 MZ
-0.3258367E+I10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED) SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
8956478.
FY
=
-9630480.
FZ
=
8956477.
MX
= -0.4162557E+10 MY
= -0.7137811E+10 MZ
-0.3258367E+10 SUMMATION POINT
0.0000 0.0000 0.0000
Sheet 134 of 151 F '*ENERCON SERVICES, INC. Appendix RL-4 to Calculation PGE-009-CALC-003 LOAD CASE 11 *********************************
USE LOAD STEP 11 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
11 SUBSTEP=
1 CUMULATIVE ITERATION=
88 TIME/FREQUENCY=
11.000 TITLE= Pad, HE(1),
Casks 1 to 12, 515 Kips West (X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-6180000.
FY
=
3204480.
FZ
=
0.9212859E-05 MX
=
0.1852189E+10 MY
=
0.3572040E+I10 MZ
=
0.1712901E+10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1267026E+08 FY
=
-9630480.
FZ
= -0.2736841E-04 MX
= -0.4473997E+10 MY
= -0.6220066E+10 MZ
-0.3387195E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS ******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1267026E+08 FY
=
-9630480.
FZ
= -0.2529359E-02 MX
= -0.4473997E+10 MY
= -0.6220066E+10
Sheet 135 of 151 F '* I ENERCON FSERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 MZ
-0.3387195E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 12
- USE LOAD STEP 12 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
12 SUBSTEP=
1 CUMULATIVE ITERATION=
93 TIME/FREQUENCY=
12.000 TITLE= Pad, HE(1),
Casks 1 to 12, 515 Kips S 45 W (-Z,X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-4369920.
FY
=
3204480.
FZ
=
4369920.
MX
=
0.2370025E+10 MY
=
0.1188618E+10 MZ
=
0.1498406E+10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
8956477.
FY
=
-9630480.
FZ
=
-8956477.
MX
= -0.4785438E+10 MY
= -0.1656447E+10 MZ
-0.3258367E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES 4
Sheet 136 of 151 r
1ENERCON
- r.
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 FX
=
8956478.
FY
=
-9630480.
FZ
=
-8956477.
MX
= -0.4785438E+10 MY
= -0.1656447E+10 MZ
-0.3258367E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 13 *********************************
USE LOAD STEP 13 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
13 SUBSTEP=
1 CUMULATIVE ITERATION=
99 TIME/FREQUENCY=
13.000 TITLE= Pad, HE(1),
Casks 1 to 12, 515 Kips South (-Z),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED) SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.3392453E-05 FY
=
3204480.
FZ
=
6180000.
MX
=
0.2584519E+10 MY
= -0.1891080E+10 MZ
=
0.9805709E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED) SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES
- n***
FX
= -0.2596076E-05 FY
=
-9630480.
FZ
= -0.1267026E+08 MX
= -0.4914266E+10 MY
=
0.3877100E+10 MZ
-0.2946927E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
Sheet 137 of 151 ENERCON F
SERVICES, INC.
Appendix RL4 to Calculation PGE-009-CALC-003 SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.5608468E-05 FY
=
-9630480.
FZ
= -0.1267026E+08 MX
= -0.4914266EI10 MY
=
0.3877100E+10 MZ
-0.2946927E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 14 *********************************
USE LOAD STEP 14 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
14 SUBSTEP=
1 CUMULATIVE ITERATION=
1il TIME/FREQUENCY=
14.000 TITLE= Pad, HE(l),
Casks 1 to 13, 515 Kips North (Z),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES
- FX
=
0.7657772E-05 FY
=
3471520.
FZ
=
-6695000.
MX
=
0.1167784E+10 MY
=
0.1891080E+10 MZ
=
0.9805709E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO I BY 1
9056 ELEMENTS (OF 15348 DEFINED) SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1573579E-04 FY
=
-9897520.
FZ
=
0.1318526E+08 MX
= -0.4081654E+10 MY
= -0.3877100E+10 MZ
-0.2946927E+10 SUMMATION POINT
0.0000 0.0000 0.0000
Sheet 138 of 151 F
l ENERCON SERVICES, INC. Appendix RL4 to Calculation PGE-009-CALC-003 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.5856292E-03 FY
=
-9897520.
FZ
=
0.1318526E+08 MX
= -0.4081654E+10 MY
= -0.3877100E+10 MZ
-0.2946927E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 15 *********************************
USE LOAD STEP 15 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
15 SUBSTEP=
1 CUMULATIVE ITERATION=
120 TIME/FREQUENCY=
15.000 TITLE= Pad, HE(l),
Casks 1 to 13, 515 Kips N 45 W (Z,X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-4734080.
FY
=
3471520.
FZ
=
-4734080.
MX
=
0.1400153E+10 MY
=
0.4011587E+10 MZ
=
0.1541559E+10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
9320637.
FY
=
-9897520.
FZ
=
9320637.
Sheet 139 of 151 ENERCON SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 MX
= -0.4228356E+10 MY
= -0.7286389E+10 MZ
-0.3301520E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
9320637.
FY
=
-9897520.
FZ
=
9320637.
MX
= -0.4228356E+10 MY
= -0.7286389E+10 MZ
-0.3301520E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 16 *********************************
USE LOAD STEP 16 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
16 SUBSTEP=
1 CUMULATIVE ITERATION=
127 TIME/FREQUENCY=
16.000 TITLE= Pad, HE(1),
Casks 1 to 13, 515 Kips West (X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-6695000.
FY
=
3471520.
FZ
=
0.1903945E-04 MX
=
0.1961142E+10 MY
=
0.3782160E+10 MZ
=
0.1773928E+10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
ENERCON F. A SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 Sheet 140 of 151 SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1318526E+08 FY
=
-9897520.
FZ
=
0.2044401E-04 MX
= -0.4582950E+10 MY
= -0.6430186E+10 MZ
-0.3448223E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1318526E+08 FY
=
-9897520.
FZ
= -0.3252108E-02 MX
= -0.4582950E+10 MY
= -0.6430186E+10 MZ
-0.3448223E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 17 *********************************
USE LOAD STEP 17 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
17 SUBSTEP=
1 CUMULATIVE ITERATION=
133 TIME/FREQUENCY=
17.000 TITLE= Pad, HE(1),
Casks I to 13, 515 Kips S 45 W (-ZX),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
-4734080.
FY
=
3471520.
FZ
=
4734080.
MX
=
0.2522130E+10 MY
=
0.1337196E+I0 MZ
=
0.1541559E+10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
Sheet 141 of 151 F '*ENERCON SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
9320637.
FY
=
-9897520.
FZ
=
-9320637.
MX
= -0.4937543E+10 MY
= -0.1805024E+10 MZ
-0.3301520E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
9320637.
FY
=
-9897520.
FZ
=
-9320637.
MX
= -0.4937543E+10 MY
= -0.1805024E+10 MZ
-0.3301520E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 18
- USE LOAD STEP 18 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
18 SUBSTEP=
1 CUMULATIVE ITERATION=
138 TIME/FREQUENCY=
18.000 TITLE= Pad, HE(l),
Casks 1 to 13, 515 Kips South (-Z),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.3773001E-05 FY
=
3471520.
FZ
=
6695000.
MX
=
0.2754499E+10 MY
= -0.1891080E+10 MZ
=
0.9805709E+09
Sheet 142 of 151
- 3ENERCON SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.1841914E-04 FY
=
-9897520.
FZ
= -0.1318526E+08 MX
= -0.5084246E+10 MY
=
0.3877100E+10 MZ
-0.2946927E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.4982649E-03 FY
=
-9897520.
FZ
= -0.1318526E+08 MX
= -0.5084246E+10 MY
=
0.3877100E+10 MZ
-0.2946927E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 19 *********************************
USE LOAD STEP 19 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
19 SUBSTEP=
1 CUMULATIVE ITERATION=
146 TIME/FREQUENCY=
19.000 TITLE= Pad, HE(l),
Casks 1 to 13, 515 Kips S 45 E (-Z,-X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
4734080.
Sheet 143 of 151 F
ENERCON FINC. Appendix RL4 to Calculation PGE-009-CALC-003 FY
=
3471520.
FZ
=
4734080.
MX
=
0.2522130E+10 MY
= -0.4011587E+10 MZ
=
0.4195824E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-9320637.
FY
=
-9897520.
FZ
=
-9320637.
MX
= -0.4937543E+10 MY
=
0.7286389E+10 MZ
-0.2592333E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-9320637.
FY
=
-9897520.
FZ
=
-9320637.
MX
= -0.4937543E+10 MY
=
0.7286389E+10 MZ
-0.2592333E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 20 *********************************
USE LOAD STEP 20 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
20 SUBSTEP=
1 CUMULATIVE ITERATION=
154 TIME/FREQUENCY=
20.000 TITLE= Pad, HE(1),
Casks 1 to 13, 515 Kips East (-x),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK
'~n ENERCON Sheet 144 of 151 F A SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
6695000.
FY
=
3471520.
FZ
= -0.2131277E-04 MX
=
0.1961142E+10 MY
= -0.3782160E+10 MZ
=
0.1872134E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.1318526E+08 FY
=
-9897520.
FZ
=
0.2011867E-04 MX
= -0.4582950E+10 MY
=
0.6430186E+10 MZ
-0.2445631E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.1318526E+08 FY
=
-9897520.
FZ
= -0.1905545E-02 MX
= -0.4582950E+10 MY
=
0.6430186E+I10 MZ
-0.2445631E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 21 *********************************
USE LOAD STEP 21 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
21 SUBSTEP=
1 CUMULATIVE ITERATION=
164 TIME/FREQUENCY=
21.000
Sheet 145 of 151 SNERCON F A SERVICES,INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 TITLE= Pad, HE(1),
Casks 1 to 13, 515 Kips N 45 E (Z,-X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK
- SUM OF LOADS APPLIED TO CASKS *
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES
- FX
=
4734080.
FY
=
3471520.
FZ
=
-4734080.
MX
=
0.1400153E+10 MY
= -0.1337196E+10 MZ
=
0.4195824E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES
- FX
=
-9320637.
FY
=
-9897520.
FZ
=
9320637.
MX
= -0.4228356E+10 MY
=
0.1805024E+10 MZ
-0.2592333E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES
- FX
=
-9320637.
FY
=
-9897520.
FZ
=
9320637.
MX
= -0.4228356E+10 MY
=
0.1805024E+10 MZ
-0.2592333E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 22 ********************************
Sheet 146 of 151 r
jENERCON r
SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 USE LOAD STEP 22 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
22 SUBSTEP=
1 CUMULATIVE ITERATION=
172 TIME/FREQUENCY=
22.000 TITLE= Pad, HE(1),
Casks 1 to 14, 515 Kips North (Z),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.2229153E-04 FY
=
3738560.
FZ
=
-7210000.
MX
=
0.1215709E+10 MY
=
0.2206260E+10 MZ
=
0.1143999E+10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED) SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.9400639E-05 FY
= -0.1016456E+08 FZ
=
0.1370026E+08 MX
= -0.4129579E+10 MY
= -0.4192280E+10 MZ
-0.3110355E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.7400165E-05 FY
= -0.1016456E+08 FZ
=
0.1370026E+08 MX
= -0.4129579E+10 MY
= -0.4192280E+10 MZ
= -0.3110355E+10
Sheet 147 of 151 F
~
ENERCON FINC. Appendix RL4 to Calculation PGE-009-CALC-003 SUMMATION POINT=
0.0000 0.0000 0.0000
- ~***~****
LOAD CASE 23
- USE LOAD STEP 23 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
23 SUBSTEP=
1 CUMULATIVE ITERATION=
181 TIME/FREQUENCY=
23.000 TITLE= Pad, HE(I),
Casks 1 to 14, 515 Kips N 45 W (Z,X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-5098240.
FY
=
3738560.
FZ
=
-5098240.
MX
=
0.1465953E+10 MY
=
0.4383030E+10 MZ
=
0.1748141E+10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
9684797.
FY
= -0.1016456E+08 FZ
=
9684797.
MX
= -0.4294156E+10 MY
= -0.7657832E+10 MZ
-0.3508102E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
9684797.
FY
= -0.1016456E+08
Sheet 148 of 151 r ~
ENERCON SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 FZ
=
9684797.
MX
= -0.4294156E+10 MY
= -0.7657832E+10 MZ
-0.3508102E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 24 *********************************
USE LOAD STEP 24 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
24 SUBSTEP=
1 CUMULATIVE ITERATION=
188 TIME/FREQUENCY=
24.000 TITLE= Pad, HE(1),
Casks 1 to 14, 515 Kips West (X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-7210000.
FY
=
3738560.
FZ
=
0.5044745E-05 MX
=
0.2070094E+10 MY
=
0.3992280E+10 MZ
=
0.1998384E+10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES
- FX
=
0.1370026E+08 FY
= -0.1016456E+08 FZ
= -0.3978522E-04 MX
= -0.4691902E+10 MY
= -0.6640306E+10 MZ
-0.3672679E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY
Sheet 149 of 151 ENERCON F
NECOSERVICES, SINC.
Appendix RL4 to Calculation PGE-009-CALC-003
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1370026E+08 FY
= -0.1016456E+08 FZ
= -0.2669406E-02 MX
= -0.4691902E+10 MY
= -0.6640306E+10 MZ
-0.3672679E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 25 *********************************
USE LOAD STEP 25 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
25 SUBSTEP=
1 CUMULATIVE ITERATION=
194 TIME/FREQUENCY=
25.000 TITLE= Pad, HE(1),
Casks 1 to 14, 515 Kips S 45 W (-Z,X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED) SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK
". SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-5098240.
FY
=
3738560.
FZ
=
5098240.
MX
=
0.2674236E+10 MY
=
0.1262907E+10 MZ
=
0.1748141E+10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
9684797.
FY
= -0.1016456E+08 FZ
=
-9684797.
MX
= -0.5089648E+10 MY
= -0.1730736E+10 MZ
-0.3508102E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
Sheet 150 of 151 ENERCON SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
9684797.
FY
= -0.1016456E+08 FZ
=
-9684797.
MX
= -0.5089648E+10 MY
= -0.1730736E+10 MZ
-0.3508102E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 26 *********************************
USE LOAD STEP 26 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
26 SUBSTEP=
1 CUMULATIVE ITERATION=
199 TIME/FREQUENCY=
26.000 TITLE= Pad, HE(l),
Casks 1 to 14, 515 Kips South (-Z),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *****
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.8825056E-05 FY
=
3738560.
FZ
=
7210000.
MX
=
0.2924479E+10 MY
= -0.2206260E+10 MZ
=
0.1143999E+10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED) SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.9578402E-05 FY
= -0.1016456E+08 FZ
= -0.1370026E+08 MX
= -0.5254225E+10 MY
=
0.4192280E+10
Sheet 151 of 151 F
'~IENERCON A SERVICES, INC.
Appendix RL-4 to Calculation PGE-009-CALC-003 MZ
-0.3110355E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1347436E-05 FY
= -0.1016456E+08 FZ
= -0.1370026E+08 MX
= -0.5254225E+10 MY
=
0.4192280E+10 MZ
-0.3110355E+10 SUMMATION POINT
0.0000 0.0000 0.0000 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
17051 NODES (OF 17051 DEFINED)
SELECTED BY NALL COMMAND.
EXIT THE ANSYS POSTi DATABASE PROCESSOR ROUTINE COMPLETED *****
CP =
80.396 NOTE ***
CP=
80.396 TIME= 16:32:21 A total of 1 warnings and errors written to dcslabs7.err.
Sheet 1 of 17 E
l ENERCON SERVICES, INC.
Appendix RL-5 to Calculation PGE-009-CALC-003 Originator: S.C. Tumminelli Date:
November 30, 2001 Appendix RL-5 Reaction Loads - Cask Extraction This Appendix presents reaction loads of the model for eight Hosgri HE(l) Load Cases, aimed at 45 degrees around the compass for the Cask Extraction configuration which is for 17 casks on the pad.
The first part of the calculation computes the expected forces. Input values are from References 2 and 4.
The sum of all applied loads are calculated followed by the sum of the forces at the pad/rock interface and the sum at the boundary of the rock. Since the rock is massless, the last two values are the same.
These are presented in the Table below. The methodology is described in Appendix RL-4. The forces computed and provided in the Table are the applied forces, with sign.
Then the database is scanned for the same data. The input and output files are provided in sequence.
The ANSYS program is providing the unbalanced forces that the elements are applying to the nodes.
Thus, the values for the nodes where the loads are applied, are actually the reactions that the elements are applying to these nodes to maintain equilibrium. Hence, the values are the negative of the applied loads. On the boundary, the values are again the forces that the elements are applying to the nodes. Thus, they have the same sign as the applied loads calculated and provided in the Table.
A comparison of the expected forces and the forces scanned from the soft rock analysis database shows that the values are the same. This indicates that the pad is in equilibrium and that, together with a review of the displacement plots, provides high confidence that the analyses are correct.
Appendix Contents Manual reaction calculations sheet 2 ANSYS input file for reactions sheet 3 ANSYS output file for reactions sheet 7
i ENERCON SERVICES, INC.
Appendix RL-5 to Calculation PGE-009-CALC-003 Table of Applied forces for 17 Casks on the Pad Sheet 2 of 17 Direction Forces Number of Direction Forces Number of of Casks on Pad of Casks on Pad Seismic Seismic Accel.
17 Accel.
17 N
Cask Fx 0
S Cask Fx 0
Load Fy
-4539680 Load Fy
-4539680 Step Fz 8755000 Step Fz
-8755000 1
Rock Fx 0
5 Rock Fx 0
Fy
-10965680 Fy
-10965680 Fz 15245260 Fz
-15245260 N 45 W Cask Fx 6190720 S 45 E Cask Fx
-6190720 Load Fy
-4539680 Load Fy
-4539680 Step Fz 6190720 Step Fz
-6190720 2
Rock Fx 10777278 6
Rock Fx
-10777278 Fy
-10965680 Fy
-10965680 Fz 10777278 Fz
-10777278 W
Cask Fx 8755000 E
Cask Fx
-8755000 Load Fy
-4539680 Load Fy
-4539680 Step Fz 0
Step Fz 0
3 Rock Fx 15245260 7
Rock Fx
-15245260 Fy
-10965680 Fy
-10965680 Fz 0
Fz 0
S 45 W Cask Fx
- 6190720 N 45 E Cask Fx
-6190720 Load Fy
-4539680 Load Fy
-4539680 Step Fz
-6190720 Step Fz 6190720 4
Rock Fx 10777278 8
Rock Fx
-10777278 Fy
-10965680 Fy
-10965680 Fz
-10777278 Fz 10777278
Sheet 3 of 17 r ~
ENERCON r 3 SERVICES, INC.
Appendix RL-5 to Calculation PGE-009-CALC-003 ANSYS input file for processing reaction loads:
/com,
/com, This routine processes load results data for the
/com, evaluation of equilibrium.
/com
/com, Soft Rock Load Step Results
/com
/output,padsoftreacS8,out
/com
/comr
/com *************************************************************************
/comr
/ corn
/com
/com Soft Rock Reactions *
/com
/file,dcslabs8 resume
/postl
/com
/com LOAD CASE 1 set,1 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,1 cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type, 2 cmsel,s,boundary
/com
/com
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
fsum
/com
/com
/com
/comr
/com LOAD CASE 2
- set,2 eall cmsel,s,cask
/com
/com ********
SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,1 cmsel,s,base
/com
Sheet 4 of 17 r
Il] ENERCON F, 3 SERVICES, INC.
Appendix RL-5 to Calculation PGE-009-CALC-003
/com ********
LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
fsum esel,type,2 cmsel,s,boundary
/com
/com
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com
/Cor
/Com
/com LOAD CASE 3 set,3 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com ********
LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com
/com
/com *************************
LOAD CASE 4 **********************************
set,4 eall cmsel,s,cask
/com
/com ********
SUM OF LOADS APPLIED TO CASKS fsum esel,type, l cmsel,s,base
/com
/com ********
LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2
/com cmsel,s,boundary
/com ********
LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com
/Com W*****
/Com
/com *************************
LOAD CASES **********************************
set,5 eall cmsel,s,cask
Sheet 5 of 17 N
°RCON F
SERVICES, INC.
Appendix RL-5 to Calculation PGE-009-CALC-003
/com
/com SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com
/com*****
/com LOAD CASE 6
- set,6 eall cmsel,s,cask
/com
/com ********
SUM OF LOADS APPLIED TO CASKS *******
f sum esel,type,1 cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
fsum
/com
/com
/com LOAD CASE 7 **********************************
set,7 eall cmsel,s,cask
/com
/com ********
SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,l cmsel,s,base
/com
/com ********
LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2 cmsel,s,boundary
/COm
"/com ********
LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com
SENERCON Sheet 6 of 17
, 3 SERVICES, INC.
Appendix RL-5 to Calculation PGE-009-CALC-003
/com LOAD CASE 8 *******************************
set,8 eall cmsel,s,cask
/Com
/com ********
SUM OF LOADS APPLIED TO CASKS fsum esel,type,l cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
- fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS f sum
/com
/com
/com
/com finish
/output
/exit
Sheet 7 of 17 S
ENERCON F
SERVICES, INC. Appendix RL-5 to Calculation PGE-009-CALC-003 ANSYS output file for reaction loads:
- *********** ~Soft Rock Reactions ****************************
CURRENT JOBNAME REDEFINED AS dcslabs8 RESUME ANSYS DATA FROM FILE NAME=dcslabs8.db
- ANSYS GLOBAL STATUS ***
TITLE = Pad, HE(1),
Cask Extraction, 17 Casks, 515 Kips N 45 ANALYSIS TYPE =
STATIC (STEADY-STATE)
NUMBER OF ELEMENT TYPES =
6 15348 ELEMENTS CURRENTLY SELECTED.
MAX ELEMENT NUMBER
=
17051 NODES CURRENTLY SELECTED.
MAX NODE NUMBER =
259 KEYPOINTS CURRENTLY SELECTED.
MAX KEYPOINT NUMBER
=
0 LINES CURRENTLY SELECTED.
MAX LINE NUMBER =
181 AREAS CURRENTLY SELECTED.
MAX AREA NUMBER =
70 VOLUMES CURRENTLY SELECTED.
MAX VOL.
NUMBER =
26 COMPONENTS CURRENTLY DEFINED MAXIMUM LINEAR PROPERTY NUMBER
=
5 MAXIMUM REAL CONSTANT SET NUMBER
=
6 ACTIVE COORDINATE SYSTEM
=
0 (CARTESIAN)
MAXIMUM CONSTRAINT EQUATION NUMBER
=
4620 NUMBER OF SPECIFIED CONSTRAINTS
=
2193 NUMBER OF NODAL LOADS 2754 E
(Z,-X),
Soft Ro 33177 17051 259 396 295 70 INITIAL JOBNAME = dcslabs8 CURRENT JOBNAME = dcslabs8 ANSYS ENGINEERING ANALYSIS SYSTEM RELEASE 5.7 ANSYS/Structural U 00150104 VERSION=INTEL NT 08:03:43 JUN 29, 2001 CP=
1.202 Pad, HE(I),
Cask Extraction, 17 Casks, 515 Kips N 45 E (Z,-X),
Soft Rock ANSYS RESULTS INTERPRETATION (POST1)
ENTER
/SHOW,DEVICE-NAME ENTER FINISH TO ENABLE GRAPHIC DISPLAY TO LEAVE POST1 NOTE CP=
1.202 TIME= 08:03:43 Reading results into the database (SET command) will update the current displacement and force boundary conditions in the database with the values from the results file for that load set.
Note that any subsequent solutions will use these values unless action is taken to either SAVE the current values or not overwrite them (/EXIT,NOSAVE).
Sheet 8 of 17 r
!ENERCON r
3 SERVICES, INC.
Appendix RL-5 to Calculation PGE-009-CALC-003
- LOAD CASE 1 USE LOAD STEP 1
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
1 SUBSTEP=
1 CUMULATIVE ITERATION=
11 TIME/FREQUENCY=
1.0000 TITLE= Pad, HE(1),
Cask Extraction, 17 Casks, 515 Kips North (Z),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1762666E-04 FY
=
4539680.
FZ
=
-8755000.
MX
=
0.6512935E+09 MY
=
0.2836620E+10 MZ
=
0.1470856E+I10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.3665291E-04 FY
= -0.1096568E+08 FZ
=
0.1524526E+08 MX
= -0.3565163E+10 MY
= -0.4822640E+10 MZ
-0.3437212E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.3530628E-02 FY
= -0.1096568E+08
Sheet 9 of 17 E
ENERCON F3 SERVICES, INC.
Appendix RL-5 to Calculation PGE-009-CALC-003 FZ
=
0.1524526E+08 MX
= -0.3565163E+10 MY
= -0.4822640E+10 MZ
-0.3437212E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 2 **********************************
USE LOAD STEP 2
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
2 SUBSTEP=
1 CUMULATIVE ITERATION=
20 TIME/FREQUENCY=
2.0000 TITLE= Pad, HE(1),
Cask Extraction, 17 Casks, 515 Kips N 45 W (Z,X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-6190720.
FY
=
4539680.
FZ
=
-6190720.
MX
=
0.9551606E+09 MY
=
0.4308741E+10 MZ
=
0.2204457E+I10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1077728E+08 FY
= -0.1096568E+08 FZ
=
0.1077728E+08 MX
= -0.3783364E+10 MY
= -0.7583543E+10 MZ
-0.3964418E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SENERCON Sheet 10 of 17 SERVICES, INC.
Appendix RL-5 to Calculation PGE-009-CALC-003 SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1077728E+08 FY
= -0.1096568E+08 FZ
=
0.1077728E+08 MX
= -0.3783364E+10 MY
= -0.7583543E+10 MZ
-0.3964418E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 3 **********************************
USE LOAD STEP 3
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
3 SUBSTEP=
1 CUMULATIVE ITERATION=
29 TIME/FREQUENCY=
3.0000 TITLE= Pad, HE(l),
Cask Extraction, 17 Casks, 515 Kips West (X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-8755000.
FY
=
4539680.
FZ
= -0.2150458E-04 MX
=
0.1688761E+10 MY
=
0.3256860E+I10 MZ
=
0.2508324E+10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1524526E+08 FY
= -0.1096568E+08 FZ
= -0.5007636E-05 MX
= -0.4310569E+10 MY
= -0.5904886E+10 MZ
= -0.4182618E+10
Sheet 11 of 17 r ~
ENERCON F
- SERVICES, INC.
Appendix RL-5 to Calculation PGE-009-CALC-003 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
"***** SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1524526E+08 FY
= -0.1096568E+08 FZ
=
0.2788214E-02 MX
= -0.4310569E+10 MY
= -0.5904886E+10 MZ
-0.4182618E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 4 **********************************
USE LOAD STEP 4
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
4 SUBSTEP=
1 CUMULATIVE ITERATION=
39 TIME/FREQUENCY=
4.0000 TITLE= Pad, HE(1),
Cask Extraction, 17 Casks, 515 Kips S 45 W (-Z,X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-6190720.
FY
=
4539680.
FZ
=
6190720.
MX
=
0.2422361E+10 MY
=
0.2971546E+09 MZ
=
0.2204457E+10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
r i*
ENERCON
- r. 3SERVICES, INC. Appendix RL-5 to Calculation PGE-009-CALC-003 Sheet 12 of 17 SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1077728E+08 FY
= -0.1096568E+08 FZ
= -0.1077728E+08 MX
= -0.4837774E+10 MY
= -0.7649834E+09 MZ
-0.3964418E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1077728E+08 FY
= -0.1096568E+08 FZ
= -0.1077728E+08 MX
= -0.4837774E+10 MY
= -0.7649834E+09 MZ
-0.3964418E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 5 **********************************
USE LOAD STEP 5
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
5 SUBSTEP=
1 CUMULATIVE ITERATION=
47 TIME/FREQUENCY=
5.0000 TITLE= Pad, HE(1),
Cask Extraction, 17 Casks, 515 Kips South (-Z),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.4336677E-04 FY
=
4539680.
FZ
=
8755000.
MX
=
0.2726228E+10 MY
= -0.2836620E+10 MZ
=
0.1470856E+10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
Sheet 13 of 17 F
- ENERCON SERVICES, INC.
Appendix RL-5 to Calculation PGE-009-CALC-003 9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.3408351E-04 FY
= -0.1096568E+08 FZ
= -0.1524526E+08 MX
= -0.5055975E+10 MY
=
0.4822640E+10 MZ
-0.3437212E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION -F TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.1035929E-03 FY
= -0.1096568E+08 FZ
= -0.1524526E+08 MX
= -0.5055975E+10 MY
=
0.4822640E+10 MZ
-0.3437212E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 6 **********************************
USE LOAD STEP 6
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
6 SUBSTEP=
1 CUMULATIVE ITERATION=
56 TIME/FREQUENCY=
6.0000 TITLE= Pad, HE(l),
Cask Extraction, 17 Casks, 515 Kips S 45 E (-Z,-X),
Soft Roc 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
6190720.
FY
=
4539680.
FZ
=
6190720.
r
'j*
ENERCON Sheet 14 of 17 I
A SERVICES, INC.
Appendix RL-5 to Calculation PGE-009-CALC-003 MX
=
0.2422361E+I10 MY
= -0.4308741E+10 MZ
=
0.7372560E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES
- FX
= -0.1077728E+08 FY
= -0.1096568E+08 FZ
= -0.1077728E+08 MX
= -0.4837774E+10 MY
=
0.7583543E+10 MZ
-0.2910007E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.1077728E+08 FY
= -0.1096568E+08 FZ
= -0.1077728E+08
" MX
= -0.4837774E+10 MY
=
0.7583543E+10 MZ
-0.2910007E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 7 **********************************
USE LOAD STEP 7
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
7 SUBSTEP=
1 CUMULATIVE ITERATION=
64 TIME/FREQUENCY=
7.0000 TITLE= Pad, HE(1),
Cask Extraction, 17 Casks, 515 Kips East (-x),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK
Sheet 15 of 17 SENERCON F 3 SERVICES, INC.
Appendix RL-5 to Calculation PGE-009-CALC-003 SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
8755000.
FY
=
4539680.
FZ
= -0.2248750E-04 MX
=
0.1688761E+10 MY
= -0.3256860E+10 MZ
=
0.4333888E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
= -0.1524526E+08 FY
= -0.1096568E+08 FZ
=
0.1691222E-04 MX
= -0.4310569E+10 MY
=
0.5904886E+10 MZ
-0.2691807E+I10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.1524526E+08 FY
= -0.1096568E+08 FZ
= -0.9676202E-03 MX
= -0.4310569E+10 MY
=
0.5904886E+10 MZ
-0.2691806E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 8
- 8 SUBSTEP 0
FOR LOAD CASE 0 USE LOAD STEP
ENERCON Sheet 16 of 17 SSERVICES, INC.
Appendix RL-5 to Calculation PGE-009-CALC-003 SET COMMAND GOT LOAD STEP=
8 SUBSTEP=
1 CUMULATIVE ITERATION=
73 TIME/FREQUENCY=
8.0000 TITLE= Pad, HE(1),
Cask Extraction, 17 Casks, 515 Kips N 45 E (Z,-X),
Soft Rock 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES
- FX
=
6190720.
FY
=
4539680.
FZ
=
-6190720.
MX
=
0.9551606E+09 MY
= -0.2971546E+09 MZ
=
0.7372560E+09 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED) SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.1077728E+08 FY
= -0.1096568E+08 FZ
=
0.1077728E+08 MX
= -0.3783364E+10 MY
=
0.7649834E+09 MZ
-0.2910007E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.1077728E+08 FY
= -0.1096568E+08 FZ
=
0.1077728E+08 MX
= -0.3783364E+10 MY
=
0.7649834E+09 MZ
-0.2910007E+10 SUMMATION POINT
0.0000 0.0000 0.0000
Sheet 17 of 17 F 14 ENERCON SERVICES, INC.
Appendix RL-5 to Calculation PGE-009-CALC-003 EXIT THE ANSYS POST1 DATABASE PROCESSOR ROUTINE COMPLETED *****
CP =
25.026 NOTE CP=
25.026 TIME= 08:04:17 A total of 1 warnings and errors written to dcslabs8.err.
Sheet 1 of 12 ENERCON F 3 SERVICES, INC.
Appendix RL-6 to Calculation PGE-009-CALC-003 Originator:
Date:
S. C. Tumminelli November 30, 2001 Appendix RL-6 Reaction Loads - Soft Rock with Nu = 0.23 This Appendix presents reaction loads of the soft rock model for three Hosgri HE (1) Load Cases and three LTSP (2) Load Cases aimed at N, N45W and W with Poisson's ratio set to 0.23.
The ANSYS input file is followed by the output file.
A comparison of the expected forces taken from Appendix RL-1 (compare LS 2, 4, 6, 11, 13, 15 in RL-1 to LS 1 to 6), and the forces scanned from the soft rock analysis database, shows that the values are the same. This indicates that the pad is in equilibrium and that, together with a review of the displacement plots, provides high confidence that the analyses are correct.
Appendix Contents ANSYS input file for reactions ANSYS output file for reactions sheet 2 sheet 5
Sheet 2 of 12 r
jENERCON r
A SERVICES, INC.
Appendix RL-6 to Calculation PGE-009-CALC-003 ANSYS input file for processing reaction loads:
/com,
/com, This routine processes load results data for the
/com, evaluation of equilibrium.
/com
/com, Soft Rock Load Step Results
/com
/output,padsoftreacs9,out
/com
/ corn ******************************************+*******************************
/oom
/com
/corn ************************ Soft Rock Reactions ****************************
/com
/f ile, dcslabs9 resume
/postl
/com
/corn *************************************************************************
/corn **************************
LOAD CASE 1 **********************************
set,l1
/com
/com
- SUM OF LOADS APPLIED TO CASKS f sum esel, type, 1 cmsel, s,base"
/com
/oom
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE frsum esel, type, 2 omsel, s,boundary
/com
/oom
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS ******
f sum
/com
/com
/ corn *************************************************************************
/com *************************
LOAD CASE 2 **********************************
set,2 eall cmsel,s,cask
/com
/com
- SUM OF LOADS APPLIED TO CASKS fsum esel,type,1 cmsel,s,base
/com
Sheet 3 of 12 ENERCON F
SERVICES, INC.
Appendix RL-6 to Calculation PGE-009-CALC-003
/com ********
LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
fsum esel,type,2 cmsel,s,boundary
/com
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
f sum
/com
/com
/com LOAD CASE 3 set,3 eall cmsel,s,cask
/COm
/com SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type, l cmsel,s,base
/com
/com LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
fsum esel,type,2 cmsel,s,boundary
/com
"/com ********
LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com
/com LOAD CASE 4
- set,4 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *******
fsum esel,type,l cmsel,s,base
/com
/com ********
LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE fsum esel,type,2
/com cmsel,s,boundary
/com LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS fsum
/com
/com
/com LOAD CASE 5 **********************************
set,5 eall cmsel,s,cask
r ENERCON Sheet 4 of 12 I
SERVICES, INC.
Appendix RL-6 to Calculation PGE-009-CALC-003
/com
/com SUM OF LOADS APPLIED TO CASKS ****
fsum esel,type,l cmsel,s,base
/com
/com
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE f sum esel, type, 2 cmsel,s,boundary
/com
/com
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS f sum
/com
/com
/com LOAD CASE 6
- set,6 eall cmsel,s,cask
/com
/com SUM OF LOADS APPLIED TO CASKS *****
fsum esel,type,l cmsel,s,base
/Com
/com ********
LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
f sum esel, type, 2 cmsel,s,boundary
/com
/com ******** LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *****
fsum
/com
/com
/com fini
/output
/exit
F
ENERCON F
i ENERCON SERVICES, INC.
Appendix RL-6 to Calculation PGE-009-CALC-003 ANSYS output file for reaction loads:
Sheet 5 of 12
- Soft Rock Reactions ****************************
CURRENT JOBNAME REDEFINED AS dcslabs9 RESUME ANSYS DATA FROM FILE NAME=dcslabs9.db ANSYS GLOBAL STATUS ***
TITLE = Pad, LTSP(2),
20 Casks, 440 Kip West (X),
Soft Rock ANALYSIS TYPE =
STATIC (STEADY-STATE)
NUMBER OF ELEMENT TYPES =
6 15348 ELEMENTS CURRENTLY SELECTED.
MAX ELEMENT NUMBER
=
17051 NODES CURRENTLY SELECTED.
MAX NODE NUMBER =
259 KEYPOINTS CURRENTLY SELECTED.
MAX KEYPOINT NUMBER
=
250 LINES CURRENTLY SELECTED.
MAX LINE NUMBER =
181 AREAS CURRENTLY SELECTED.
MAX AREA NUMBER =
70 VOLUMES CURRENTLY SELECTED.
MAX VOL.
NUMBER =
11 COMPONENTS CURRENTLY DEFINED MAXIMUM LINEAR PROPERTY NUMBER
=
5 MAXIMUM REAL CONSTANT SET NUMBER
=
6 ACTIVE COORDINATE SYSTEM
=
0 (CARTESIAN)
MAXIMUM CONSTRAINT EQUATION NUMBER
=
4620 NUMBER OF SPECIFIED CONSTRAINTS
=
2193 NUMBER OF NODAL LOADS 2160 (Nu = 0.23) 33177 17051 259 396 295 70 INITIAL JOBNAME
dcslabs9 CURRENT JOBNAME = dcslabs9 ANSYS ENGINEERING ANALYSIS SYSTEM RELEASE 5.7 ANSYS/Structural U 00150104 VERSION=INTEL NT 16:09:36 JUN 28, 2001 CP
Pad, LTSP(2),
20 Casks, 440 Kip West (X),
Soft Rock (Nu = 0.23)
ANSYS RESULTS INTERPRETATION (POST1)
ENTER
/SHOW,DEVICE-NAME ENTER FINISH TO ENABLE GRAPHIC DISPLAY TO LEAVE POST1 NOTE ***
CP=
3.535 TIME= 16:09:36 Reading results into the database (SET command) will update the current displacement and force boundary conditions in the database with the values from the results file for that load set.
Note that any subsequent solutions will use these values unless action is taken to 3.535
Sheet 6 of 12 r ~jENERCON r ý SERVICES, INC.
Appendix RL-6 to Calculation PGE-009-CALC-003 either SAVE the current values or not overwrite them (/EXIT,NOSAVE).
LOAD CASE 1 **********************************
USE LOAD STEP 1
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
1 SUBSTEP=
1 CUMULATIVE ITERATION=
12 TIME/FREQUENCY=
1.0000 TITLE= Pad, HE(l),
20 Casks, 515 Kip N (Z),
Soft Rock (Nu = 0.23) 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES
- FX
=
0.3674820E-04 FY
=
5340800.
FZ
= -0.1030000E+08 MX
=
0.9584964E+09 MY
=
0.3151800E+10 MZ
=
0.1634285E+10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE
- LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.3662529E-04 FY
= -0.1176680E+08 FZ
=
0.1679026E+08 MX
= -0.3872366E+10 MY
= -0.5137820E+10 MZ
-0.3600641E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
= -0.5910846E-05
Sheet 7 of 12 ENERCON SSERVICES,INC.
Appendix RL-6 to Calculation PGE-009-CALC-003 FY
= -0.1176680E+08 FZ
=
0.1679026E+08 MX
= -0.3872366E+I10 MY
= -0.5137820E+10 MZ
-0.3600641E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 2 *********************************
USE LOAD STEP.
2 SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
2 SUBSTEP=
1 CUMULATIVE ITERATION=
22 TIME/FREQUENCY=
2.0000 TITLE= Pad, HE(1),
20 Casks, 515 Kip N 45 W (Z,X),
Soft Rock (Nu = 0.23) 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-7283200.
FY
=
5340800.
FZ
=
-7283200.
MX
=
0.1315987E+10 MY
=
0.5200205E+10 MZ
=
0.2497344E+10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1186976E+08 FY
= -0.1176680E+08 FZ
=
0.1186976E+08 MX
= -0.4144190E+10 MY
= -0.8475007E+10 MZ
-0.4257305E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
Sheet 8 of 12 r
jENERCON r
J SERVICES, INC.
Appendix RL-6 to Calculation PGE-009-CALC-003 SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
0.1186976E+08 FY
= -0.1176680E+08 FZ
=
0.1186976E+08 MX
= -0.4144190E+10 MY
= -0.8475007E+10 MZ
-0.4257305E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 3 **********************************
USE LOAD STEP 3
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
3 SUBSTEP=
1 CUMULATIVE ITERATION=
32 TIME/FREQUENCY=
3.0000 TITLE= Pad, HE(1),
20 Casks, 515 Kip West (W),
Soft Rock (Nu = 0.23) 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.1030000E+08 FY
=
5340800.
FZ
=
0.1745064E-04 MX
=
0.2179046E+10 MY
=
0.4202400E+10 MZ
=
0.2854835E+10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1679026E+08 FY
= -0.1176680E+08 FZ
=
0.1546240E-04 MX
= -0.4800854E+10 MY
= -0.6850426E+10
Sheet 9 of 12 F
l ENERCON SERVICES, INC. Appendix RL-6 to Calculation PGE-009-CALC-003 MZ
-0.4529129E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1679026E+08 FY
= -0.1176680E+08 FZ
=
0.6384819E-03 MX
= -0.4800854E+10 MY
= -0.6850426E+10 MZ
-0.4529129E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 4 **********************************
USE LOAD STEP 4
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
4 SUBSTEP=
1 CUMULATIVE ITERATION=
47 TIME/FREQUENCY=
4.0000 TITLE= Pad, LTSP(2),
20 Casks, 440 Kip N (Z),
Soft Rock (Nu = 0.23) 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.7554507E-05 FY
=
5166400.
FZ
=
-8800000.
MX
=
0.1065091E+10 MY
=
0.2692800E+10 MZ
=
0.1580918E+10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
Sheet 10 of 12 F
ENERCON SSERVICES, INC. Appendix RL-6 to Calculation PGE-009-CALC-003
- SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
= -0.2412734E-04 FY
= -0.1094980E+08 FZ
=
0.1598106E+08 MX
= -0.3747866E+10 MY
= -0.4890203E+10 MZ
-0.3350639E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY
- LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
= -0.9249689E-05 FY
= -0.1094980E+08 FZ
=
0.1598105E+08 MX
= -0.3747866E+10 MY
= -0.4890203E+10 MZ
-0.3350639E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 5 USE LOAD STEP 5
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
5 SUBSTEP=
1 CUMULATIVE ITERATION=
56 TIME/FREQUENCY=
5.0000 TITLE= Pad, LTSP(2),
20 Casks, 440 Kip N 45 W (Z,X),
Soft Rock (Nu = 0.23) 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
-6222540.
FY
=
5166400.
FZ
=
-6222540.
MX
=
0.1370520E+10 MY
=
0.4442894E+10 MZ
=
0.2318289E+10 SUMMATION POINT=
0.0000 0.0000 0.0000
Sheet 11 of 12 F
ENERCON F SERVICES, INC.
Appendix RL-6 to Calculation PGE-009-CALC-003 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED) SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1129908E+08 FY
= -0.1094980E+08 FZ
=
0.1129908E+08 MX
= -0.3958592E+10 MY
= -0.8067543E+10 MZ
-0.3859565E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1129908E+08 FY
= -0.1094980E+08 FZ
=
0.1129908E+08 MX
= -0.3958592E+10 MY
= -0.8067543E+10 MZ
-0.3859566E+10 SUMMATION POINT
0.0000 0.0000 0.0000 LOAD CASE 6 **********************************
USE LOAD STEP 6
SUBSTEP 0
FOR LOAD CASE 0 SET COMMAND GOT LOAD STEP=
6 SUBSTEP=
1 CUMULATIVE ITERATION=
65 TIME/FREQUENCY=
6.0000 TITLE= Pad, LTSP(2),
20 Casks, 440 Kip West (X),
Soft Rock (Nu = 0.23) 15348 ELEMENTS (OF 15348 DEFINED)
SELECTED BY EALL COMMAND.
SELECT COMPONENT CASK SUM OF LOADS APPLIED TO CASKS *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES *****
FX
=
-8800000.
FY
=
5166400.
Sheet 12 of 12 r
~J ENERCON r
SERVICES, INC.
Appendix RL-6 to Calculation PGE-009-CALC-003 FZ
= -0.1693612E-04 MX
=
0.2107891E+10 MY 0.3590400E+10 MZ
=
0.2623718E+10 SUMMATION POINT=
0.0000 0.0000 0.0000 ESEL FOR LABEL= TYPE FROM 1 TO 1 BY 1
9056 ELEMENTS (OF 15348 DEFINED) SELECTED BY ESEL COMMAND.
SELECT COMPONENT BASE LOADS TRANSMITTED THRU CONCRETE/ROCK INTERFACE *******
SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1598106E+08 FY
= -0.1094980E+08 FZ
= -0.1160489E-04 MX
= -0.4467518E+10 MY
= -0.6520270E+10 MZ
-0.4070291E+10 SUMMATION POINT
0.0000 0.0000 0.0000 ESEL FOR LABEL.
TYPE FROM 2 TO 2 BY 1
1728 ELEMENTS (OF 15348 DEFINED)
SELECTED BY ESEL COMMAND.
SELECT COMPONENT BOUNDARY LOADS REACTED AT ROCK BOUNDARY CONSTRAINTS SUMMATION OF TOTAL FORCES AND MOMENTS IN GLOBAL COORDINATES FX
=
0.1598105E+08 FY
= -0.1094980E+08 FZ
=
0.7216000E-03 MX
= -0.4467518E+10 MY
= -0.6520270E+10 MZ
-0.4070291E+10 SUMMATION POINT
0.0000 0.0000 0.0000 EXIT THE ANSYS POST1 DATABASE PROCESSOR
- ROUTINE COMPLETED *****
=
21.381 NOTE ***
CP=
21.381 TIME= 16:10:04 A total of 2 warnings and errors written to dcslabs9.err.