Wolf Creek Initial Examinations December, 2001 Examination Outline Review Comments Reviewer: T. McKernon/ R. Lantz Chief Examiner: H. Bundy Written Exam:

Ensure reference examination copy designates which 10CFR55.43 topic area is represented by each SRO only question. Resolution: Incorporated.

Walkthrough:

None Admin:

SRO A4 looks like a simple question. Need to ask a second question for evaluation of conditions for EAL and Pars, or combine both into a JPM to evaluate, classify, determine PARS and fill out notification forms. Resolution: Developed JPM as recommended.

SRO A3 is non-discriminatory as written, add difficulty, such as determining stay-times, or ALARA calculations based on different scenario choices. Resolution: Increased difficulty by having applicant use survey map to determine stay time and protective clothing requirements.

Simulator Scenarios:

Scenario 2, Event 7 and JPM B.1.d may have very similar actions... if so, replace JPM.

Resolution: Replaced JPM B.1.d.