Regulatory Guide 5.22

From kanterella
(Redirected from ML003739999)
Jump to navigation Jump to search
Assessment of the Assumption of Normality (Employing Individual Observed Values)
ML003739999
Person / Time
Issue date: 04/30/1974
From:
Office of Nuclear Regulatory Research
To:
References
RG-5.22
Download: ML003739999 (2)


April 1974 U.S. ATOMIC ENERGY COMMISSION

REGULATORY GUIDE

DIRECTORATE OF REGULATORY STANDARDS

REGULATORY GUIDE 5.22 ASSESSMENT OF THE ASSUMPTION OF

NORMALITY (EMPLOYING INDIVIDUAL OBSERVED VALUES)

A. INTRODUCTION

Part 70 of Title 10 of the Code of Federal Regulations requires certain AEC special nuclear material (SNM) licensees to establish and maintain written material control and accounting procedures to enable the licensee to account for the special nuclear material in his possession. Part 70 also requires applicants for certain AEC licenses for SNM to submit to the Commission as part of the application a full description of such procedures, including statistical controls. The effectiveness of such controls depends greatly upon the validity of the statistical procedures applied.

A key assumption often encountered in applications is that the measured value is a random variable that can be described by a normal or Gaussian distribution function. This guide identifies methods acceptable to the Regulatory staff for assessing the validity of such an assumption.

B. DISCUSSION

The general role of statistical methodology in SNM

accountability is to serve as the basis for evaluations which objectively provide assurance that material in the possession of licensees is accounted for effectively and that losses are localized when they occur.

In maintaining material balances, it is usually impracticable to assay (observe) every item in a material process batch or lot (population). It would also be impossible, of course, to measure any material an infinite number of times. Accountability systems must thereftre rely on observing a portion (sample) of the population being measured, from which general conclusions can be inferred about the population. Such statistically calculated inferences based on sample measurement data are basically predictions of what would be found if the sampled populations could be and were fully observed. The validity of inferences made on the basis of an assumed frequency function is dependent on the extent to which the assumed distribution describes the actual measurement process.

One of the most frequent assumptions made in developing and applying statistical procedures for treating measurement data is that observations comprising a sample were drawn from a population which can be described by a normal distribution. The examination of a typical set of measurements which adequately represent the distribution will show the individual measurement values clustering around the average, forming a symmetrical bell-shaped pattern. Two parameters, the mean and the variance, are sufficient to define a normal distribution of a particular set of data under examination.

Most statistical interval estimates and tests commonly used in practice are based on the assumption of normal distribution. Two features tend to promote the usage of the normal distribution, sometimes without sufficient investigation as to whether its assumption is justified. One is its usual applicability and the other is the fact that its mathematical operations are comparatively simple and well known. The basic procedural assumption that a measured random variable is normally distributed can often permit slight to moderate departures from normality without significantly affecting conclusions, depending on the statistical technique employed. However when decisions are based on the outcome of a statistical test, there is always a risk that a wrong conclusion has been reached, and any decision based on incomplete information runs the risk of either rejecting a true hypothesis or accepting a false one. The discernibility (power) of a statistical test will depend significantly upon the quantity and quality of data tested. A major departure from the normality assumption could result in misleading conclusions. For example, the level of control could be incorrectly determined and assessed if measurement errors are not USAEC REGULATORY GUIDES

Copies of published guides may be obtained by request indicating the divisions desired to the US. Atomic Energy Commission, Washington. D.C. 20645, Regulatory Guides are issued to descibe and make availabe to the public Attention: Director of Regulatory Standards. Comments end suggestions for methods acceptable to the AEC Regulatory staff of Implemening specific parts of improvements in these guides; ae encouraged and should be sent to the Sacretary the Commission's regulations, to delineate techniques used by the staff in of the Commission, US. Atomic Energy Commission, Washington, D.C. 20645, ealuating specific problems or postulated accidents, or to provide guidance to Attention: Chief, Public Proceedings Staff.

a

1lmnts.

Regulatory Gu~des are not substitutes for regulations and compliance with them is not required. Methods and solutions different from thoee set out in The guides ore issued in the following ten broad divisions:

the guides will be acceptable if they provide a basis for the findings requisite to Power Reactors

6. Products the issuance or continuance of a permit or license by the Commission.

2. RParch end Test Reactors

7. TransPortatoon

3. Fuels and Materials Facilities S. Occupational Health Publtshad guides will be revined periodically, as aperon riate, to acc

o. odate

4. Environmental and Siting

9. Antitrust Review comments and to reflect now inforiation or experience.

5. Materials and Plant Protection

1

0. General

characterived properly in the calculation of limits of error. This could seriously affect the facility's ability to control quantities of material unaccounted for and to cvaluate their significance. Therefore, the testing of the assumption of normality merits consideration as a c;ntrol procedure.

Subcommittee N15-3 of the American National Standards Institute (ANSI) Standards Committee NIS,

Methods of Nuclear Materials Control, has developed a standard for assessing the assumption of normality (employing individual observed values). This standard has been designated ANSI N15.15-1973.'

' Copies may be obtained from the American National Standards Institute, Inc., 1430 Broadway, New York, New York

10018.

C. RFGULATORY POSITION

The statistical hypothesis testing techniques contained in the approved standard, ANSI N15.15-1973,

"Assessment of the Assumption of Normality (Employing Individual Observed Vnhues)," '1 are generally acceptable to the Regulatory staff for use in written procedures for the control of special nuclear material subject to the following. The interpretation of the significance of results from the application of the test of normality should consider the amount of data treated (sample size), in particular whether there are enough data available to reach a meaningful conclusion pertaining to the validity of the assumption for a given process.

5.22-2