Regulatory Guide 8.29
| ML003739401 | |
| Person / Time | |
|---|---|
| Issue date: | 07/31/1981 |
| From: | Office of Nuclear Regulatory Research |
| To: | |
| References | |
| RG-8.29 | |
| Download: ML003739401 (17) | |
"REQUo( U.S. NUCLEAR REGULATORY COMMISSION
July lU16 R EGULT
GUIDE
OFFICE OF NUCLEAR REGULATORY RESEARCH
REGULATORY GUIDE 8.29 (Tusk OH 9024)
INSTRUCTION CONCERNING RISKS FROM OCCUPATIONAL RADIATION EXPOSURE
A. INTRODUCTION
Section 19.12 of 10 CFR Part 19, "Notices, Instructions and Reports to Workers; Inspections," requires that all persons working in or frequenting any portion of a restricted area be instructed in the health protection problems asso ciated with exposure to radioactive materials or radiation.
This guide describes the instruction that should be provided to the worker concerning biological risks from occupational radiation exposure. Additional guides are being or will be developed to address other aspects of radiation protection training.
B. DISCUSSION
It is generally accepted by the scientific community that exposure to ionizing radiation can cause biological effects that are harmful to the exposed organism. These effects are classified into three categories:
Somatic Effects:
Effects occurring in the exposed person that, in turn, may be divided into two classes:
Prompt effects that are observable soon after a large or acute dose (e.g., 100 remsi or more to the whole body in a few hours), and Delayed effects such as cancer that may occur years after exposure to radiation.
Genetic Effects:2 Abnormalities that may occur in the future children of exposed individuals and in subsequent generations.
Teratogenic Effects:
Effects that may be observed in children who were exposed during the fetal and embryonic stages of development.
1In the International System of Units (SI) the rem is replaced by the sievert. 100 reins is equal to I sievert (Svi).
2 Genetic effects exceeding normal incidence have not been observed in any of the studies of exposed humans.
USNRC REGULATORY GUIDES
Regulatory Guides are issued to describe and make available to the public methods acceptable to the NRC staff of Implementing specific parts of the Commission's regulations, to delineate tech niques used by the staff in evaluating specific problems or postu lated accidents, or to provide guidance to applicants. Regulatory Guides are not substitutes for regulations, and compliance with them is not required. Methods and solutions different from those set out in the guides will be acceptable If they provide a basis for the findings requisite to the issuance or continuance of a permit or license by the Commission.
This guide was issued after consideration of comments received from the public. Comments and suggestions for Improvements In these guides are encouraged at all times, and guides will be revised, as appropriate, to accommodate comments and to reflect new informa tion or experience.
Concerns about these biological effects have resulted in controls on doses to individual workers and in efforts to control the collective dose (person-reins) to the worker population.
NRC-licensed activities result in a significant fraction of the total occupational radiation exposure in the United States. Regulatory action has recently focused more atten tion on maintaining occupational radiation exposure at levels that are as low as is reasonably achievable (ALARA).
Radiation protection training for all workers who may be exposed to ionizing radiation is an essential component of any program designed to maintain exposure levels ALARA.
A clear understanding of what is presently known about the biological risks associated with exposure to radiation will result in more effective radiation protection training and should generate more interest on the part of the worker in minimizing both individual and collective doses. In addition, radiation workers have the right to whatever information on radiation risk is available to enable them to make informed decisions regarding the acceptance of these risks. It is intended that workers who receive this instruction develop a healthy respect for the risks involved rather than excessive fear or indifference.
At the relatively low levels of occupational radiation exposure in the United States, it is difficult to demonstrate a relationship between exposure and effect. There is con siderable uncertainty and controversy regarding estimates of radiation risk. In the appendix to this guide, a range of risk estimates is provided (see Table 1). Information on radiation risk has been included from such sources as the
1980 National Academy of Sciences' Report of the Committee on the Biological Effects of Ionizing Radiation (BEIR-80),
the International Commission on Radiological Protection (ICRP) Publication 27 entitled "Problems in Developing an Index of Harm," the 1979 report of the science work group of the Interagency Task Force on the Health Effects of Ionizing Radiation, the 1977 report of the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR report), and numerous published articles (see the bibliography to the appendix).
Comments should be sent to the L..cretary of the Commission, U.S. Nuclear Regulatory Commission, Washington, D.C. 20555, Attention: Docketing and Service Branch.
The guides are Issued In the followlhg ten broad divisions:
1. Power Reactors
6. Products
2. Research and Test Reactors
7. Transportation
3. Fuels and Materials Facilities
8. Occupational Health
4. Environmental and Siting
9. Antitrust and Financial Review
5. Materials and Plant Protection 10. General Copies of Issued guides may be purchased at the current Government Printing Office price. A subscription service for future guides In spe cific divisions Is available through the Government Printing Office.
Information on the subscription service and current GPO prices may be obtained by writing the U.S. Nuclear Regulatory Commission, Washington, D.C. 20555, Attention: Publications Sales Manager.
SAat
C. REGULATORY POSITION
Strong management support is considered essential to an adequate radiation protection training program. Instruction to workers performed in compliance with § 19.12 of 10 CFR
Part 19 should be given prior to assignment to work in a restricted area and periodically thereafter. In providing instruction concerning health protection problems associated with exposure to radiation, all workers, including those in supervisory roles, should be given specific instruction on the risk of biological effects resulting from exposure to radiation.
The instruction should be presented both orally and in printed form to all affected workers and supervisors. It should include the information provided in the appendix to this guide. 3 The information should be discussed during training
3 Copies of the appendix to this gulde are available at the current Government Printing Office price, which may be obtained by writing to the U.S. Nuclear Regulatory Commission, Washington, D.C.
20SS, Attention: Publications Sales Manager. This appendix is not copyrighted, and Commission approval is not required to reproduce it.
sessions. Each individual should be given an opportunity to ask questions and should be asked to acknowledge in writing that the instruction has been received and understood.
D. IMPLEMENTATION
The purpose of this section is to provide information to applicants regarding the NRC staff's plans for using this regulatory guide.
Except in those cases in which an applicant or licensee proposes an acceptable alternative method for complying with specified portions of the Commission's regulations, the methods described in this guide will be used in the evalua tion of the training program for all individuals working in or frequenting any portion of a restricted area and for all supervisory personnel after December 15, 1981.
If an applicant or licensee wishes to use the material pro vided in this guide on or before December 15, 1981, the pertinent portions of the application or the licensee's perfor mance will be evaluated on the basis of this guide.
8.29-2
U.S. NUCLEAR REGULATORY COMMISSION
APPENDIX TO REGULATORY GUIDE 8.29 INSTRUCTION CONCERNING RISKS FROM OCCUPATIONAL RADIATION EXPOSURE
This instructional material is intended to provide the user with the best available information concerning what is currently known about the health risks from exposure to ionizing radiation. 1 A question and answer format has been used. The questions were developed by the NRC staff in consultation with workers, union representatives, and licensee representatives experienced in radiation protection training. Risk estimates have been compiled from numerous sources generally recognized as reliable. A bibliography Is included for the user interested in further study.
1.
What is meant by risk?
Risk can be defined in general as the probability (chance)'
of injury, illness, or death resulting from some activity.
However, the perception of risk is affected by how the individual views its probability and its severity. The intent of this document is to provide estimates of and explain the basis for possible risk of injury, illness, or death resulting from occupational radiation exposure. (See Questions 9 and
10 for estimates of radiation risk and comparisons with other types of risk.)
2.
What are the possible health effects of exposure to radiation?
Some of the health effects that exposure to radiation may cause are cancer (including leukemia), birth defects in the future children of exposed parents, and cataracts. 3 These effects (with the exception of genetic effects) have been observed in studies of medical radiologists, uranium miners, radium workers, and radiotherapy patients who have received large doses of radiation. Studies of people exposed to radiation from atomic weapons have also provided data on radiation effects. In addition, radiation effects studies with laboratory animals have provided a large body of data on radiation-induced health effects, including genetic effects.
The observations and studies mentioned above, hovever, involve levels of radiation exposure that are much higher (hundreds of rems) than those permitted occupationally today ( <5 rems per year). Although studies have not shown a cause-effect relationship between health effects and current levels of occupational radiation exposure, it is prudent to
1lIonizing radiation consists of energy or small particles such as gamma, beta, or alpha radiation emitted from radioactive materials which, when absorbed by living tissue, can cause chemical and physical damage.
2The rem is the unit of measure for radiation dose and relates to the biological effect of the absorbed radiation.
The biological effects that are known to occur after exposure to high doses (hundreds of rems2 ) of radiation are discussed early in the document; discussions of the esti mated risks from the low occupational dose (<5 rams per year) follow. It is intended that this information will help develop an attitude of healthy respect for the risks asso ciated with radiation, rather than unnecessary fear or lack of concern. Additional guidance is being or will be devel oped concerning other topics in radiation protection training.
assume that some health effects do occur at the lower expo sure levels.
3.
What is meant by prompt effect, delayed effects. and genetic effects?
a. Prompt effects are observable shortly after receiving a very large dose in a short period of time. For example, a whole-body 4 dose of 450 rems (90 times the annual dose limit for routine occupational exposure) in an hour to an average adult will cause vomiting and diarrhea within a few hours; loss of hair, fever, and weight loss within a few weeks; and about a 50 percent chance of death within
60 days without medical treatment.
b. Delayed effects such as cancer may occur years after exposure to radiation.
c. Genetic effects can occur when there is radiation damage to the genetic material. These effects may show up as birth defects or other conditions in the future children of the exposed individual and succeeding generations, as demonstrated in animal experiments. However, excess genetic effects clearly caused by radiation have not been observed in human populations exposed to radiation. It has been observed, however, that radiation can change the genes in cells of the human body. Thus, the possibility exists that genetic effects can be caused in humans by low doses even though no direct evidence exists as yet.
4.
In worker protection, which effects are of nwst concern to the NRC?
The main concern to the NRC is the delayed incidence of cancer. The chance of delayed cancer is believed to depend
3Cataracts differ from other radiation effects in that a certain level of dose to the lens of the eye (-_200 rems) is required before they are observed.
41t is important to distinguish between whole-body and partial body exposure. 100 rems to the whole body will have more effect than 100 to a hand. For example, exposure of a hand would affect a small fraction of the bone marrow and a limited portion of the skin.
8.29-3
on how much radiation exposure a person gets; therefore, every reasonable effort should be made to keep exposures low.
Immediate or prompt effects are very unlikely since large exposures would normally occur only if there were a serious radiation accident. Accident rates in the radiation industry have been low, and only a few accidents have resulted in exposures exceeding the legal limits. The probabil ity of serious genetic effects in the future children of workers is estimated in the BEIRs report, based on animal studies, at less than one-third that of delayed cancer (5-65 genetic effects per million reins compared to 160-450
cancer cases). A clearer understanding of the cause-effect relationship between radiation and human genetic effects will not be possible until additional research studies are completed.
5.
What is the difference Oetween acute and chronic exposure?
Acute radiation exposure, which causes prompt effects and may also cause delayed effects, usually refers to a large dose of radiation received in a short period of time; for example, 450 rems received within a few hours or less. The effects of acute exposures are well known from studies of radiotherapy patients, some of whom received whole-body doses; atomic bomb victims; and the few accidents that have occurred in the early days of atomic weapons and reactor development, industrial radiography, and nuclear fuel processing. There have been few occupational incidents that have resulted in large exposures. NRC data indicate that, on the average, 1 accidental overexposure in which any acute symptoms are observed occurs each year. Most of these occur in industrial radiography and involve exposures of the hands rather than the whole body.
Chronic exposure, which may cause delayed effects but not prompt effects, refers to small doses received repeatedly over long time periods; for example,20-100 mrem (a mrem is one-thousandth of a rem) per week every week for several years. Concern with occupational radiation risk is primarily focused on chronic exposure to low levels of radiation over long time periods.
6.
How does radiation cause cancer?
How radiation causes cancer is not well understood.
It is impossible to tell whether a given cancer was caused by radiation or by some other of the many apparent causes.
However, most diseases are caused by the interaction of several factors. General physical condition, inherited traits, age, sex, and exposure to other cancer-causing agents such as cigarette smoke are a few possible contributing factors.
5The National Academy of Sciences established a committee on the Biological Effects of Ionizing Radiation (BEIR) whose 1980
report on the effects ondpopulations of exposure to low levels of ionizing radiation provides much of the background for this guide.
One theory is that radiation can damage chromosomes in a cell, and the cell is then directed along abnormal growth patterns. Another is that radiation reduces the body's normal resistance to existing viruses which can then multiply and damage cells. A third is that radiation activates an existing virus in the body which then attacks normal cells causing them to grow rapidly.
What is known is that, in groups of highly exposed people, a higher than normal incidence of cancer is observed.
Higher than normal rates of cancer can also be produced in laboratory animals by high levels of radiation. An increased incidence of cancer has not been demonstrated at radiation levels below the NRC limits.
7 If I receive a radiation dose, does that mean I am certain to get cancer?
Not at all. Everyone gets a radiation dose every day (see Question 25), but most people do not get cancer. Even with doses of radiation far above legal limits, most individuals will experience no delayed consequences. There is evidence that some radiation damage can be repaired. The danger from radiation is much like the danger from cigarette smoke.
Only a fraction of the people who breathe cigarette smoke get lung cancer, but there is good evidence that smoking increases a person's chances of getting lung cancer. Similarly, there is evidence that the larger the radiation dose, the larger the increase in a person's chances of getting cancer.
Radiation is like most substances that cause cancer in that the effects can be seen clearly only at high doses Estimates of the risks of cancer at low levels of exposure are derived from data available for exposures at high dose levels and high dose rates. Generally, for radiation protection purposes these estimates are made using the linear model (Curve 1 in Figure 1). We have data on health effects at high doses as shown by the solid line in Figure
1. Below about
100 reins, studies have not been able to accurately measure the risk, primarily because of the small numbers of exposed people and because the effect is small compared to differences in the normal incidence from year to year and place to place.
Most scientists believe that there is some degree of risk no matter how small the dose (Curves I and 2). Some scientists believe that the risk drops off to zero at some low dose (Curve 3), the threshold effect. A few believe that risk levels off so that even very small doses imply a significant risk (Curve 4). The majority of scientists today endorse either the linear model (Curve I) or the linear-quadratic model (Curve 2). The NRC endorses the linear model (Curve I),
which shows the number of effects decreasing as the dose decreases, for radiation protection purposes.
It is prudent to assume that smaller doses have some chance of causing cancer. This is as true for natural cancer causers such as sunlight and natural radiation as it is for those that are man made such as cigarette smoke, smog, and man-made radiation. As even very small doses may entail some small risk, it follows that no dose should be taken without a reason. Thus, a principle of radiation protection is to do more than merely meet the allowed regulatory
8.29-4 I
LU
Ca, LuI
U.
ULU
100
DOSE (REMS)
Figure 1. Some proposed models for how the effects of radiation vary with doses at low levels.
limits; doses should be kept as low as is reasonably achievable (ALARA).
We don't know exactly what the chances are of getting cancer from a low-level radiation dose, but we can make estimates based on extensive scientific knowledge. The estimates of radiation risks are at least as reliable as estimates for the effects from any chemical hazard. Being exposed to typical occupational radiation doses is taking a chance, but that chance is reasonably well understood.
It is important to understand the probability factors here. A similar question would be: If you select one card from a full deck, will you get the ace of spades?
This question cannot be answered with a simple yes or no. The best answer is that your chances are 1 in 52. However, if
1000 people each select one card from full decks, we can predict that about 20 of them will get an ace of spades.
Each person will have I chance in 52 of drawing the ace of spades, but there is no way that we can predict which persons will get the right card. The issue is further complicated by the fact that in 1 drawing by 1000 people, we might get only
15 successes and in another perhaps 25 correct cards in
1000 draws. We can say that if you receive a radiation dose, you will have increased your chances of eventually developing cancer. It is assumed that the more radiation exposure you get, the more you increase your chances of cancer.
Not all workers incur the same level of risk. The radia tion risk incurred by a worker depends on the amount of dose received. Under the linear model explained above, a worker who receives 5 rems in a year incurs 10 times as much risk as another worker (the same age) who receives only 0.5 rem. The risk depends not only on the amount of dose, but also on the age of the worker at the time the dose is received. This age difference is due, in part, to the fact that a young worker has more time to live than an older worker, and the risk is believed to depend on the number of years of life following the dose. The more years left, the larger the risk. It should be clear that, even within the regulatory dose limits, the risk may vary a great deal from one worker to another. Fortunately, only a very few workers receive doses near 5 rems per year; as pointed out in the answer to Question 19, the average annual dose for all radiation workers is less than 0.5 rem.
8.29-5
A reasonable comparison involves exposure to the sun's rays, Frequent short exposures provide time for the skin to repair. An acute exposure to the sun can result in painful burning, and excessive exposure has been shown to cause skin cancer. However, whether exposure to the sun's rays is short term or spread over time, some of the injury is not repaired and may eventually result in skin cancer.
The effect upon a group of workers occupationally exposed to radiation may be an increased incidence of cancer over and above the number of cancers that would normally be expected in that group. Each exposed individual has an increased probability of incurring subsequent cancer.
We can say that if 10,000 workers each receive an additional I rem in a year, that group is more likely to have a larger incidence of cancer than 10,000 people who do not receive the additional radiation. An estimate of the. increased probability of cancer from low radiation doses delivered to large groups is one measure of occupational risk and is discussed in Question 9.
8.
What groups of expert scientists have studied the risk from exposure to radiation?
In 1956, the National Academy of Sciences established advisory committees to consider radiation risks. The fixst of these was the Advisory Committee on the Biological Effects of Atomic Radiations (BEAR) and more recently it was renamed the Advisory Committee on the Biological Effects of Ionizing Radiation (BEIR). These committees have periodically reviewed the extensive research being done on the health effects of ionizing radiation and have published estimates of the risk of cancer from exposure to radiation
(1972 and 1980 BEIR reports). The International Commission on Radiological Protection (ICRP) and the National Council on Radiation Protection and Measurement (NCRP) are two other groups of scientists who have studied radiation effects and published risk estimates (ICRP Publication 26, 1977).
These two groups have no government affiliation. In addition, the United Nations established an independent study group that published an extensive report in 1977, including estimates of cancer risk from ionizing radiation (UNSCEAR, 1977).
Several individual research groups or scientists such as Alice Stewart, E.S. Gilbert, T.F. Mancuso, T.W. Anderson, to name a few, have published studies concerning low-level.
radiation effects. The bibliography to this appendix includes several articles for the reader who wishes to do further study. The BEIR-80 report includes analysis of the work of many independent researchers.
9.
What are the estimates of the risk of cancer from radia tion exposure?
The cancer risk estimates (developed by the organiza tions identified in Question 8) are presented in Table 1.
In an effort to explain the significance of these estimates, we will use an approximate average of 300 excess cancer cases per million people, each exposed to I rem of ionizing radiation. If in a group of 10,000 workers each receives TABLE 1 Estimates of Excess Cancer Incidence from Exposure to Low-Level Radiation Source Number of Additionala Cancers Estimated to Occur in I Million People After Exposure of Each to I Rem of Radiation BEIR, 1980
ICRP, 1977
200
UNSCEAR, 1977
150-350
aAdditional means above the normal incidence of cancer.
bAll three groups estimated premature deaths from radiation induced cancers. The American Cancer Society has recently stated that only about one-half of all cancer cases are fatal. Thus, to estimate incidence of cancer, the published numbers were multiplied by 2. Note that the three groups are in close agreement on the risk of radiation-induced cancer.
I rem, we could estimate that three would develop cancer because of that exposure, although the actual number could be more or less than three.
The American Cancer Society has reported that approxi mately 25 percent of all adults in the 20- to 65-year age bracket will develop cancer at some time from all possible causes such as smoking, food, alcohol, drugs, air pollutants and natural background radiation. Thus in any group ot
10,000 workers not exposed to radiation on the job, we can expect about 2,500 to develop cancer. If this entire group of 10,000 workers were to receive an occupational radiation dose of I rem' each, we could estimate that three additional cases might occur which would give a total of about 2,503.
This means that a I-rem dose to each of 10,000 workers might increase the cancer rate from 25 percent to 25.03 percent, an increase of about 3 hundredths of one percent.
As an individual, if your cumulative occupational radia tion dose is 1 rem, your chances of eventually developing cancer during your entire lifetime may have increased from
25 percent to 25.03 percent. If your lifetime occupational dose is 10 rems, we could estimate a 25.3 percent chance of developing cancer. Using a simple linear model, a lifetime dose of 100 rems may have increased your chances of cancer from 25 to 28 percent.
The normal chance of developing cancer if you receive no occupational radiation dose is about equal to your chance of getting any spade on a single draw from a full deck of playing cards, which is one chance out of four. The addi tional chance of developing cancer from an occupational exposure of I rem is less than your chances of drawing an ace from a full deck of cards three times in a row.
Since cancer resulting from exposure to radiation usually occurs 5 to 25 years after the exposure and since not all cancers are fatal, another useful measure of risk is years of
8.29-6 I
I
life expectancy lost on the average from a radiation-induced cancer. It has been estimated in several studies that the average loss of life expectancy from exposure to radiation Is about I day per rem of exposure. In other words, a person exposed to 1 rem of radiation may, on the average, lose
1 day of life. The words "on the average" are important, however, because the person who gets cancer from radiation may lose several years of life expectancy while his coworkers suffer no loss. The ICRP estimated that the average number of years of life lost from fatal industrial accidents is 30
while the average number of years of life lost from a fatal radiation-induced cancer is 10, The shorter loss of life expectancy is due to the delayed onset of cancer.
It is important to realize that these risk numbers are only estimates. Many difficulties are involved in designing research studies that can accurately measure the small increases in cancer cases due to low exposures to radiation as compared to the normal rate of cancer. There is still uncertainty and a great deal of controversy with regard to estimates of radiation risk. The numbers used here result from studies involving high doses and high dose rates, and they may not apply to doses at the lower occupational levels of exposure. The NRC and other agencies both in the United States and abroad are continuing extensive long-range research programs on radiation risk.
Some members of the National Academy of Sciences BEIR Advisory Committee and others feel that risk estimates in Table 1 are higher than would actually occur and represent an upper limit on the risk. Other scientists believe that the estimates are low and that the risk could be higher.
However, these estimates are considered by the NRC staff to be the best available that the worker can use to make an informed decision concerning acceptance of the risks asso ciated with exposure to radiation. A worker who decides to accept this risk should make every effort to keep exposure to radiation ALARA to avoid unnecessary risk. The worker, after all, has the first line responsibility for protecting himself from radiation hazards.
10.
How can we compare radiation risk to other kinds of health risks?
Perhaps the most useful unit for comparison among health risks is the average number of days of life expectancy lost per ,unit of exposure to each particular health risk.
Estimates are calculated by looking at a large number of per sons, recording the age when death occurs from apparent causes, and estimating the number of days of life lost as a result of these early deaths. The total number of days of life lost is then averaged over the total group observed.
Several studies have compared the projected loss of life expectancy resulting from exposure to radiation with other health risks. Some representative numbers are presented in Table 2.
These estimates indicate that the health risks from occu pational radiation exposure are smaller than the risks asso ciated with many other events or activities we encounter and accept in normal day-to-day activities.
TABLE2 Estimated Low of Life Expectancy from Health RUWks1 Estimates of Days of Life Expectancy Lost, Health Risk Smoking 20 cigarettes/day Overweight (by 20%)
All accidents combined Auto accidents Alcohol consumption (U.S. average)
Home accidents Drowning Natural background radiation, calculated Medical diagnostic x-rays (U.S.
average), calculated All catastrophes (earthquake, etc.)
1 rem occupational radiation dose, calculated (industry average for the higher-dose job categories is
0.65 rem/yr)
1 rem/yr for 30 years, calculated
2370 (6.5 years)
985 (2.7 years)
435 (1.2 years)
200
130
95
41
8
6
3.5
1
30
aAdapted from Cohen and Lee, "A Catalogue of Risks," Health Physcs, Vol. 36, June 1979.
A second useful comparison is to look at estimates of the average number of days of life expectancy lost from exposure to radiation and from common industrial accidents at radiation-related facilities and to compare this number with days lost from other occupational accidents. Table 3 shows average days of life expectancy lost as a result of fatal work-related accidents. Note that the data for occupa tions other than radiation related do not include death risks from other possible hazards such as exposure to toxic chem icals, dusts, or unusual temperatures. Note also that the unlikely occupational exposure at 5 rems per year for 50
years, the maximum allowable risk level, may result in a risk comparable to the average risks in mining and heavy construction.
Industrial accident rates in the nuclear industry and related occupational areas have been relatively low during the entire history of the industry (see Table 4). This is believed to be due to the early and continuing emphasis on tight safety controls. The relative safety of various occupa tional areas can be seen by comparing the probability of death by accident per 10,000 workers over a 40-year working lifetime. These figures do not include death from possible causes such as exposure to toxic chemicals or radiation.
II.
Can a worker become sterile or impotent from occupa tional radiation exposure?
Observation of radiation therapy patients who receive localized exposures, usually spread over a few weeks, has
8.29-7 Average
TABLE 3 Estimated Loss of Life Expectancy from Industrial Hazards&
Estimates of Days of Life Expectancy Lost, Industry Type Average All industry
74 Trade
30
Manufacturing
43 Service
47 Government
55 Transportation and utilities
164 Agriculture
277 Construction
302 Mining and quarrying
328 Radiation accidents, death from,
< I
exposure Radiation dose of 0.65 rem/yr
20
(industry average) for 30 years, calculated Radiation dose of 5 rems/yr for
250
50 years Industrial accidents at nuclear
58 facilities (nonradiation)
aAdaptod from Cohen and Lee, "A Catalogue of Risk," Health Phyis, Vol. 36, June 1979; and World Health Oripnization, Health Implications of Nuclear Power Production, December 1975.
TABLE 4 Probability of Accidental Death by Type of Occupationa Number of Accidental Deaths for 10,000
Occupation Workers for 40 Years Mining Construction Agriculture Transportation and public utilities All industries Government Nuclear industry (1 975 data excluding construction)
Manufacturing Services Wholesale and trade
252
228
216
116
56
44
40
36
28
24 aAdapted from National Safety Council, Accident Facts, 1979;
and Atomic Energy Commission, Operational Accidents and Radia.
tion Exposure Experience, WASH-I 192, 1975.
shown that a dose of 500-800 reins to the gonads can produce permanent sterility in males or females (an acute whole-body dose of this magnitude would probably result in death within 60 days). An acute dose of 20 reins to the testes can result in a measurable but temporary reduction in sperm count. Such high exposures on the job could result only from serious and unlikely radiation accidents. Although high doses of radiation can affect fertility, they have no effect on the ability to function sexually. Likewise, exposure to permitted occupational levels of radiation has no observed effect on fertility and also has no effect on the ability to function sexually.
12.
What are the NR C external radiation dose limits?
Federal regulations currently limit occupational external wholl-body radiation dose to 1/ 4 reins in any calendar quarter or specified 3-month period. However, when there is d xcumented evidence that a worker's previous occupa tional dose is low enough, a licensee may permit a dose of up to 3 reins per quarter or 12 reins per year. The accumulated dose may not exceed 5(N - 18) reins 6 where N is the person's age in years, i.e., the lifetime occupational dose may not exceed an average of 5 rems for each year above the age of 18.
An additional whole-body dose of approximately
5 reins per year is permitted from internal exposure. (See Question 28.)
13.
What is meant by ALARA?
In addition to providing an upper limit on a person's permissible radiation exposure, the NRC also requires that its licensees maintain occupational exposures as far below the limit as is reasonably achievable (ALARA). This means that every activity at a nuclear facility involving exposure to radiation should be planned so as to minimize unnecessary exposure to individual workers and also to the worker population. A job that involves exposure to radiation should be scheduled only when it is clear that the benefit justifies the risks assumed. All design, construction, and operating procedures should be reviewed with the objective of reducing unnecessary exposures.
14.
Has the ALARA concept been applied if, iustead of reaching dose limits during the first week of a quarter, the worker's dose is spread out over the whole quarter?
No. For radiation protection purposes, the risk of cancer from low doses is assumed to be proportional to the amount of exposure, not the rate at which it is received.
Thus it is assumed that spreading the dose out over time or over larger numbers of people does not reduce the overall risk. The ALARA concept has been followed only when the individual and collective doses are reduced by reducing the time of exposure or decreasing radiation levels in the
6 The NRC has published a proposed rule change for public comment that would eliminate the 5(N-I 8) formula. This proposal i currently under consideration by a task force reviewing all of 10 CFR
Part 20. Recent EPA guidance recommends eliminating the S(N-l 8)
formula. If adopted, the maximum allowed annual dose will be 5 reins rather than 12.
8.29-8 I
-1
-1,
individual and collective doses are reduced by reducing the time of exposure .or decreasing radiation levels in the working environment.
15.
What is meant by collective dose and why should it be maintained ALARA?
Nuclear industry activities expose an increasing number of people to occupational radiation in addition to the radia tion doses they receive from natural background radiation and medical radiation exposures, The collective occupational dose (person-reins) is the sum of all occupational radiation exposure received by all the workers in an entire worker population. For example, if 100 workers each receive 2 rems, the individual dose is 2 rems and the collective dose is 200
person-reins. The total additional risk of cancer and genetic effects in an exposed population is assumed to depend on the collective dose.
It should be noted that, from the viewpoint of risk to a total population, it is the collective dose that must be con trolled. For a given collective dose, the number of health effects is assumed to be the same even if a larger number of people share the dose. Therefore, spreading the dose out may reduce the individual risk, but not that of the population:
Efforts should be made to maintain the collective dose ALARA so as not to unnecessarily increase the overall popula tion incidence of cancer and genetic effects.
16.
Is the use of extra workers a good way to reduce risks?
There is a "yes" answer to this question and a "no"
answer. For a given job involving exposure to radiation, the more people who share the work, the lower the average dose to an individual. The lower the dose, the lower the risk. So, for you as an individual, the answer is "yes."
But how about the risk to the entire group of workers?
Under assumptions used by the NRC for purposes of protec tion, the risk of cancer depends on the total amount of radiation energy absorbed by human tissue, not on the number of people to whom this tissue belongs. Therefore, if
30 workers are used to do a job instead of 10, and if both groups get the same collective dose (person-reins), the total cancer risk is the same, and nothing was gained for the group by using 30 workers. From this viewpoint the answer is "no."
The risk was not reduced but simply spread aroun'd among a larger number of persons.
Unfortunately, spreading the risk around often results in a larger collective dose for the job. Workers are exposed as they approach a job-, while they are getting oriented to do the job, and as they withdraw from the job. The dose received during these actions is called nonproductive. If several crew changes are required, the nonproductive dose can become very large. Thus it can be seen that the use of extra workers may actually increase the total occupational dose and the resulting collective risks.
The use of extra workers to comply with NRC dose limits is not the way to reduce the risk of radiation-induced cancer for the worker population. At best, the total risk remains the same, and it may even be increased. The only way to reduce the risk is to reduce the collective dose; that can be done only by reducing the radiation levels, the working times, or both.
17.
Why doesn't the NRC impose collective dose limits?
Compliance with individual dose limits can be achieved simply by using extra workers. However, compliance with a collective dose limit (such as 100 person-rems per year for a licensee) would require reduction of radiation levels, working times, or both. But there are many problems associated with setting appropriate collective dose limits.
For example, we might consider applying a single collective dose limit to all licensees. The selection of such a collective dose limit would be almost impossible because of the wide variations in collective doses among licensees.
A power reactor could reasonably be expected to have an average annual collective dose of several hundred person reins. However, a small industrial radiography licensee could very well hive a collective dose of only a few person reins in a year.
Even choosing a collective dose limit for a group of similar licensees would be almost as difficult. Radiography licensees as a group had an average collective dose in 1977 of 9 person-reins. However,. the smallest collective dose for a radiography licensee was less than 1 person-rem, and the largest was 401 person-reins.
Setting a reasonable collective dose limit for each indi vidual licensee would also be very difficult. It would require a record of all past collective doses on which to base such limits. Setting an annual collective dose limit would then amount to an attempt to predict a reasonable collective dose for each future year. In order to do this, it would be necessary to be able to predict changes in each licensed activity that would increase or decrease the collective dose.
In addition, annual collective doses vary significantly from year to year according to the kind and amount of mainte nance required, which cannot generally be predicted in advance. Following all such changes and revising limits up and down would be very difficult if not impossible. However, these efforts would be necessary if a collective dose limit were to be reasonable and help minimize doses and risks.
18.
How are radiation dose limits established?
The NRC establishes occupational radiation dose limits based on guidance to Federal agencies from the Environmental Protection Agency (EPA) and, in addition, considers NCRP and ICRP recommendations. Scientific reviews of research data on biological effects such as the BEIR report are also considered.
For example, recent EPA guidance recommended that the annual whole-body dose limit be established at 5 reins per year and indicated that exposure, year after year, to 5 rems would involve a risk to a worker comparable to the average risks incurred by workers in the higher risk jobs
8.29-9
such as mining. In fact, few workers ever reach such a limit, much less year after year, and the risks associated with actual exposures are considered by the EPA to be comparable to the safer job categories. A 5-rem-per-year limit would allow occasional high dose jobs to be done without excessive risk.
19.
What are the typical radiation doses received by workers?
The NRC requires that certain categories of licensees report data on annual worker doses and doses for all workers who leave employment with licensees. Data were received on the occupational doses in 1977 of approximately 100,000
workers in power reactors, industrial radiography, fuel processing and fabrication facilities, and manufacturing and distribution facilities. Of this total group, 85 percent received an annual dose of less than I rem; 95 percent received less than 2 reins; fewer than 1 percent exceeded
5 rems in 1 year. The average annual dose of those workers who were monitored and had measurable exposures was about 0.65 rem. A study completed by the EPA, using
1975 exposure data for 1,260,000 workers, indicated that the average annual dose for all workers who received a measurable dose was 0.34 rem.
Table 5 lists average occupational exposures for workers (persons who had measurable exposure above background levels) in various occupations, based on the 1975 data.
TABLE 5 U.S. Occupational Exposure Estimatesa Average Whole.
Body Dose (millirems)
Medicine Industrial Radiography Source Manufacturing Power Reactors Fuel Fabricationi and Reprocessing Uranium Enrichment Nuclear Waste Disposal Uranium Mills Department of Energy Facilities Department of Defense Facilities Educational Institutions Transportation
320
580
630
760
560
70
920
380
300
180
206
200
Collective Dose (person-reins)
51,400
5,700
2,500
21,400
3,100
400
100
760
11,800
10,100
1,500
2,300
"Adapted from Cook and Nelson, Occupational Exposures to Ionizing Radiatfon in the United States: A Comprehensive Summary for 1975, Draft, Environmental Protection Agency.
20.
What happens if a worker exceeds the quarterly expo sure limit?
Radiation protection limits, such as 3rems in 3 months, are not absolute limits below which it is safe and above which there is danger. Exceeding a limit does not imply that you have suffered an injury. A good comparison is with the highway speed limit, which is selected to limit accident risl and still allow you to get somewhere. If you drive at mph, you increase your risk of an auto accident to levels that are not considered acceptable by the people who set speed limits, even though you may not actually have an accident. If a worker's radiation dose repeatedly exceeds 3 rems in a quarter, the risk of health effects could eventually increase to a level that is not considered acceptable to the NRC. Exceeding an* NRC protection limit does not mean that any adverse health effects are going to occur. It does mean that a licensee's safety program has failed in some respect and that the NRC and the licensee should investigate to make sure the problems are corrected.
If an overexposure occurs, the regulations prohibit any additional occupational exposure to that person during the remainder of the calendar quarter in which the overexposure occurred. The licensee is required to file an overexposure report to the NRC and may possibly be subject to a fine, just as you are subject to a traffic fine for exceeding the speed limit. In both cases, the fines and, in some serious or repetitive cases, suspension of license are intended to encourage efforts to operate within the limits. The safest limits would be 0 mph and 0 rem per quarter. But then we wouldn't get anywhere.
21.
Why do some facilities establish administrative limits that are below the NRC limits?
There are two reasons. First, the NRC regulations stat%
that licensees should keep exposures to radiation ALARA.
By requiring specific approval for worker doses in excess of set levels, more careful risk-benefit analysis can be made as each additional increment of dose is approved for a worker.
Secondly, a facility administrative limit that is set lower than the quarterly NRC limit provides a safety margin designed to help the licensee avoid overexposures.
22.
Several scientists have suggested that NRC limits are too high and should be lowered What are the arguments for lowering the limits?
In general, those critical of present dose limits say that the individual risk is higher than is estimated by the BEIR
Committee, the ICRP, and UNSCEAR. Based on studies of low-level exposures to large groups, some researchers have concluded that a given dose of radiation may be more likely to cause biological effects than previously thought. Some of these studies are listed in the bibliography (Manquso, Archer) and the BEIR-80 report includes a section analyzing the findings of these and other studies. Scientific opinion differs on the validity of the research methods used and the methods of statistical analysis. The problem is that the expected additional incidence of radiation-caused .effects such as cancer is difficult to detect in comparison with the much larger normal incidence. It cannot be shown withou question that these effects were more frequent in the exposed study group than in the unexposed group used for comparison, or that the observed effects were caused
8.29-10
Occupational Subgroup I
IL
I
by radiation. The BEIR committee concluded that claims of higher risk had "no substance."
The NRC staff continually reviews the results of research on radiation risks. With respect to large-scale studies of radiation-induced health effects in human populations exposed to low-level ionizing radiation, the NRC and EPA
have recently concluded that there is no one population group available for which such a study could be expected to provide a more meaningful estimate of the low-level radia tion risk. This is due, in large part, to the observed and estimated low incidence of radiation health effects from low doses. However, the results of ongoing studies, such as that on nuclear shipyard workers, will be carefully reviewed and the development of a radiation-worker registry is being considered as a possible data base for future studies.
23.
What are the reasons for not lowering the NRC dose limits?
Assuming that the 5-rem-per-year limit is adopted, there are three reasons:
a. Health risks are already low.
The estimated health risks associated with current average occupational radiation doses (e.g., 0.5 tem/yr for
50 years) are comparable to or less than risk levels in other occupational areas considered to be among the safest, if a person were exposed to the maximum of 5 reins per year for 50 years, which virtually never occurs, he or she might incur a risk comparable to the average risks in mining and heavy construction. An occasional 5-remi annual dose might be necessary to allow some jobs to be done without a significant increase in the collective dose. If the dose limits were lowered significantly, the number of people required to complete many jobs would increase. The collective dose would then increase since more individuals would be receiving nonproductive exposure while entering and leaving the work area and preparing for the job. The total number of health effects might go up as the collective dose increased.
b. The current regulations are considered sound.
The regulatory standards for dose limits are based on the recommendations of ,the Federal Radiation Council.
At the time these standards were developed, about 1960, it was considered unlikely that exposure to these levels during a working lifetime would result in clinical evidence of injury or disease different from that occurring in the unexposed population. The scientific data base for the standards consisted primarily of human experience (x-ray exposures to medical practitioners and patients, ingestion of radium by watch dial painters, early effects observed in Japanese atomic bomb survivors, radon exposures of uranium miners, occupational radiation accidents) involving very large doses delivered at high dose rates. The data base also included the results of a large number of animal experiments involving high doses and dose rates. The animal experiments were particularly useful in the evaluation of genetic effects. The observed effects were related to low- level radiation according to the linear model explained in Question 7. Based on this approach, the regulations in 10 CFR
Part 20, "Standards for Protection Against Radiation," also state that licensees should maintain all radiation exposures, and releases of radioactive materials in effluents, as low as is reasonably achievable. More recent scientific reviews of the large body of experimental data, such as the BEIR-80 and the recent EPA guidance, continue to support the view that use of a 5-rem-per-year limit is acceptable in practice.
Experience has shown that, under this limit, the average dose to workers is near 0.5 rem/yr with very few workers consistently approaching the limit.
c. There is little to gain.
Reducing the dose limits, for example, to 0.5 rem/yr has been analyzed by the NRC staff. An estimated 2.6 million person-reins could be saved from 1980 through the year
2000 by nuclear power plant licensees if compliance with the new limit were achieved by lowering the radiation levels, working times, or both, rather than by using extra workers. It is estimated that something like $ 23 billion would be spent toward this purpose. Spending $23 billion to save
2.6 million person-reins would amount to spending $30 to
$90 million to prevent each potential radiation-induced premature cancer death. Society considers this cost unaccept ably high for individual protection.
24.
Are there any areas of concern about radiation risks that might result in changing the NRC dose limits?
Yes. Three areas of concern to the NRC staff are specifi cally identified below:
a. An independent study by Rossi and Mays and other biological research have indicated that a given dose of neutron radiation may be more likely to cause biological effects than was previously thought. Other recent studies cast doubt on the issue. The NCRP is currently studying the data related to the neutron radiation question and is expected to make recommendations as to whether neutron dose .limits should be changed. Although the scientific community has not yet come to agreement on this question, workers should be advised of the possibility of higher risk when entering areas where exposure to neutrons will occur.
b. It has been known for some time that rapidly growing living tissue is more sensitive to injury from radiation than tissue in which the cells are not reproducing rapidly.
Thus the embryo or fetus is more sensitive to radiation injury than an adult. The NCRP recommended in Report No. 39 that special precautions be taken when an occupa tionally exposed woman could be pregnant in order to protect the embryo or fetus. In 1975, the NRC issued Regulatory Guide 8.13, "Instruction Concerning Prenatal Radiation Exposure," in which it is recommended thai licensees instruct all workers concerning this special risk The guide recommends that all workers be advised that thi NCRP recommended that the maximum permissible dose tc the embryo or fetus from occupational exposure of tht mother should not exceed 0.5 rem for the full 9-montl pregnancy period. In addition, the guide suggests option
8.29-11
available to the female employee who chooses not to expose her embryo or fetus to this additional risk.
The United States Department of Health and Human Services is similarly concerned about prenatal exposure from medical x-rays. In 1979 they published proposed guidelines for physicians concerning abdominal x-rays for possibly pregnant women. The guidelines in effect encourage the x-ray staff to make efforts to determine whether a female patient is pregnant and to defer x-rays if possible until after the child is born.
c. Also of special interest is the indication that female workers are subject to more risk of cancer incidence than male workers. In terms of all types of cancer except leukemia,,
the BEIR-80 analysis indicates that female workers have a risk of developing radiation-induced cancer that is approxi mately one and one-half times that for males. This increased risk is primarily due to the incidence of breast and thyroid cancer in women. These types of cancer, however, have a high cure rate. Thus the difference between men and women in cancer mortality is not great. Incidence of radiation-induced leukemia is about the same for both sexes. Female workers should be aware of this difference in the risks of radiation-induced cancer in deciding whether or not to seek work involving exposure to radiation.
25. How much radiation does the average person who does not work in the nuclear industry receive?
We are all exposed from the moment of conception to ionizing radiation from several sources. Our environment, and even the human body, contains naturally occurring radioactive materials that contribute some of the background radiation we receive. Cosmic radiation originating in space and in the sun contributes additional exposure. The use of x-rays and radioactive materials in medicine and dentistry adds considerably to our population exposure.
Table 6 shows estimated average individual exposure in millirems from natural background and other sources.
TABLE 6 U.S. General Population Exposure Estimates (1 9 7 8)a Source Natural background (average in U.S.)
Release of radioactive material in natural gas, mining, milling, etc.
Medical (whole-body equivalent)
Nuclear weapons (primarily fallout)
Nuclear energy Consumer products Total Average Individual Dose (mrem/yr)
100
5
90
5-8
0.28
0.03
,u200 mrem/yr aAdapted from a report by the Interagency Task Force on the Health Effects of Ionizing Radiation pubished by the Department of Health, Education, and Welfare.
Thus, the average individual in the general population receives about 0.2 rem of radiation exposure each year from sources that are a part of our natural and man-made environment. By the age of 20 years, an individual has accumulated about 4 rems. The most likely target for reduction of population exposure is medical uses.
26.
Why aren 't medical exposures considered as part of a worker's allowed dose?
Equal doses of medical and occupational radiation have equal risks. Medical exposure to radiation should be justified for reasons quite different, however, from those applicable to occupational exposure. A physician prescribing an x-ray should be convinced that the benefit to the patient of the resulting medical information justifies the risk associated with the radiation. Each worker must decide on the accept ance of occupational radiation risk just as each worker must decide on the acceptability of any other occupational hazard.
For another point of view, consider a worker whoreceives a dose of 2 reins from a series of x-rays or a radioactive medicine in connection with an injury or illness. This dose and the implied risk should be justified on medical grounds.
If the worker had also received a dose of 2 rems on the job, the combined dose of 4 rems would not incapacitate the worker. A dose of 4 rems is not especially dangerous and is not large compared to the cumulative lifetime dose. Restrict ing the worker from additional job exposure during the remainder of the quarter would have no effect one way or the other on the risk from the 2 reins already received from medical exposure. If the individual worker accepts the risks associated with the x-rays on the basis of the medical benefits and the risks associated with job-related exposure on the basis of employment benefits, it would be unfair to restrict the individual from employment in radiation areas for the remainder of the quarter.
Some therapeutic medical doses such as those received from cobalt-60 treatment can range as high as 6000 rems to a small part of the body, spread over a period of several weeks or months.
27.
What is meant by internal exposure?
The total radiation dose to the worker is the external dose (measured by the film badge and reported as "whole body dose") plus the dose from internal emitters. The monitoring of the additional internal dose is difficult.
Because there is the possibility of internal doses occurring, a good air-monitoring program should be established when warranted.
The uptake of radioactive materials by workers is gener ally due to breathing contaminated air. Radioactive materials may be present as fine dust or gases in the workplace atmosphere. The surfaces of equipment and workbenches
7It is likely that a significant portion of reported medical x-ray exposure is to parts of the body only. An exposure of 100 mrem to the whole body is more significant than a 100-mrem chest x-ray.
8.29-12 I
I
L
may be contaminated. Radioactive materials may enter the body by being breathed in, taken in with food or drink, or being absorbed through the sking pgrticularly if the skin is broken.
I I I
After entering the body, the radioactive material will migrate to particular organs or particular parts of the body depending on the biochemistry of the material. For example, uranium will tend to deposit in the bones where it will remain for a long time. It is slowly -eliminated, from the body, mostly by way of the kidneys. Radium will also tend to deposit in the bones. Radioactive iodine will ,seek out the thyroid glands (located in the neck) and, deposit there.
The dose from these internal emitters cannot be mea sured either by the film badge or by other ordinary dosim eters carried by the worker. This means'that the internal radiation dose must be separately monitored using other detection methods.
Internal exposure can be estimated by measuring the radiation emitted, from the body or by measuring the radioactive materials contained in biological samples such as urine or feces. Dose estimates can also be made if one.
knows how much radioactive material is in the air and the length of time during which the air was breathed.
28.
How are the limits for internal exposure set?
Standards have been established for the maximum permissible amount of each radionuclide that may be accumulated in the critical organs8 of the worker's body.
Calculations are made to determine the quantity of radioactive material that has been taken into the body and the total dose that would result. Then, based on limits established for particular body organs similar to 11/4 reins in a calendar quarter for whole-body exposure, the regula tions specify maximum permissible concentrations of radio active material in the air to which a worker can be exposed for 40 hours4.62963e-4 days <br />0.0111 hours <br />6.613757e-5 weeks <br />1.522e-5 months <br /> per week over 13 weeks or 1 calendar quarter.
The regulations also require that efforts be made to keep internal exposure ALARA.
Internal exposure is controlled by limiting the release of radioactive material into the air and by carefully monitoring the work area for airborne radioactivity and surface con tamination. Protective clothing and respiratory (breathing)
protection should be used whenever the possibility of contact with loose radioactive material cannot be prevented.
29.
Is the dose a person received fom internal exposure added to that received from external exposure?
Exposure to radiation that results from radioactive materials taken into the body is measured, recorded, and reported to the worker separately from external dose. The internal dose to the whole body or to specific organs does not at this time count against the 3-rem-per-calendar-quarter
8 Critical organ refers to those parts of the body vulnerable to radia tion damage such as bone, lungs, thyroid, and other systems where certain radioactive materials will concentrate if taken into the body.
limit. ICRP recommends that the internal and external doses should be appropriately added. This recommendation is currently under study by the staffs of the NRC, the EPA,
and the Occupational Safety and Health Administration (OSHA).
30.
How it a worker's external radiation dose determined?
A worker may Wear three types of radiation-measuring devices. A self-reading pocket dosimeter records the exposure to incident radiation and can be read out immediately upon finishing a job involving external exposure to radiation. A
film badge or TLD badge records radiation dose, either by the amount of darkening of the film or by storing energy in the TLD crystal. Both these devices require processing to determine the dose but are considered more reliable than the pocket dosimeter. A worker's official report of dose received is normally based on film or TLD badge readings, which provide a cumulative total and are more accurate.
31.
What are my options ifI decide not to accept the risks associated with occupational radiation exposure?
If the risks from exposure to radiation that may be expected to occur during your work are unacceptable to you, you could request a transfer to a job that does not involve exposure to radiation. However, the risks associated with exposure to radiation that workers, on the average, actually receive are considered acceptable, compared to other occupational risks, by virtually all the scientific groups that have studied them. Your employer is probably not obligated to guarantee you a transfer if you decide not to-accept an assignment requiring exposure to radiation.
You also have the option of seeking other employment in a nonradiation occupation. However, the studies that have compared occupational risks in the nuclear industry to those in other job areas indicate that nuclear work is relatively safe. Thus, you will not necessarily find signif icantly lower risks in another job.
A third option would be to practice the most effective work procedures so as to keep your exposure ALARA. Be aware that reducing time of exposure, maintaining distance from radiation sources, and using shielding can all lower your exposure. Plan radiation jobs carefully to increase efficiency while in the radiation area. Learn the most effective methods of using protective clothing to avoid contamination. Discuss your job with the- radiation protec tion personnel who can suggest additional ways to reduce your exposure.
32.
Where can I get additional ijWormation on radiation risk?
The following list suggests sources of useful informa tion on radiation risk:
a. Your Employer The radiation protection or health physics office in the facility where you are employed.
8.29-13
b. Nuclear Regluklato Commisoion Regional Office#
King of Pruslia, PA 19406 Atlanta, GA 30303 Glen Ellyn, IL 60137 Arlington, TX 76012 Walnut Creek, CA 94596
215-337-5000
404-221-4503
312-932-2500
817-334-2841
415-943.3700
Headquarters Occupational Radiation Protection Branch Office of Nuclear Regulatory Research U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Telephone: 301.443-5970
A, Depirtmen t o Health and Human Service#
Office of the Director Bureau of Radiological Health (HPX-.)
Department of Health and Human Services
5600 Fishers Lane Rockville, MD 20857 Telephone: 301-443-4690
d. Environmental Protection Agency Office of Radiation Programs U.S. Environmental Protection Agency
401 M Street, SW
Washington, D.C. 20460
Telephone: 703-557-9710
8.29-14 I
BIBLIOGRAPHY
American Cancer Society, 1979 Cancer Facts and Figures,
1978.
Anderson, T.W., "Radiation Exposure of Hanford Workers:
A Critique of the Mancuso, Stewart, and Kneale Report,"
Health Physics, Vol. 35, December 1978.
Archer, V.E., "Effects of Low-Level Radiation: A Critical Review," Nuclear Safety, Vol. 21, No. 1, January-February
1978.
Atomic Energy Commission, Operational Accidents and Radiation Exposure Experience, WASH-1192, Fall 1975.
Barnett, M.H., The Biological Effects of Ionizing Radiation:
An Overview, Department of Health, Education, and Welfare Publication (FDA) 77-8004, October 1976.
Cohen, B.L., and Lee, I.S., "A Catalog of Risks," Health Physics, Vol. 36, June 1979.
Cook, J., and Nelson, D., Occupational Exposures to Ionizing Radiation in the United States: A Comprehensive Summary for 1975, EPA 520/4-80-001, Environmental Protection Agency.
Department of Health, Education, and Welfare, Biologic Effects of Ionizing Radiation, Report of the Science Work Group of the Interagency Task Force on Radiation, June 1979.
Dreyer, N.A., et al., The Feasibility of Epidemiologic Inves tigations of the Health Effects of Low-Level Ionizing Radia tion, NUREG/CR-1728, Nuclear Regulatory Commission, November 1980.
Gilbert, E.S., "Assessment of Risks from Occupational Exposure to Ionizing Radiation," in Energy and Health Proceedings of the Conference on Energy and Health, June
26-30, 1978, SIAM Publication, Philadelphia, 1979.
Gofman, J.W., "The Question of Radiation Causation of Cancer in Hanford Workers," Health Physics, Vol. 37, November 1979.
Gotchy, R.L., "Estimation of Life Shortening Resulting from Radiogenic Cancer per Rem of Absorbed Dose,"
Health Physics, Vol. 35, October 1978.
Hall, E.J., Radiation and Life, Pergamon Press, 1976.
International Commission on Radiological Protection, Problems Involved in Developing an Index of Harm, Annals of the ICRP, ICRP Publication 27, Pergamon Press, May 1977.
International Commission on Radiological Protection, Radia tion Protection, Recommendations of the International Commission on Radiological Protection, ICRP Publication 26, Pergamon Press, January 1977.
Kelsey, C.A., "Comparison of Relative Risk from Radiation Exposure and Other Common Hazards," Health Physics, Vol. 35, August 1978.
Lapp, R.E., The Radiation Controversy, Reddy Communica tions, Inc., Greenwich, Connecticut, 1979.
Lapp, R.E., A Worker's Guide to Radiation, Atomic Industrial Forum, August 1979.
Linos, A., et al., "Low Dose Radiation and Leukemia, Mayo Clinic and Foundation, Rochester, Minn.," New England Journal of Medicine 1980; Vol. 302, pp. 1101-1105.
Mancuso, T.F., Stewart, A., and Kneale, G., "Radiation Expo sures of Hanford Workers Dying from Cancer and Other Causes," Health Physics, Vol. 33, November 1977.
Mulkie, R., "N'atura' Radiajion Baukground vs. Radiaticn from Nuclear Power Plants," Journal of Environmental Sciences, August 1972.
Najarian, T., and Colton, T., "Mortality from Leukemia and Cancer in Shipyard Nuclear Workers," Lancet, I: May 1978.
National Academy of Sciences, The Effects on Populations of Exposure to Low Levels of Ionizing Radiation, Report of; the Committee on the Biological Effects of Ionizing Radiation (BEIR), 1980.
Rossi and Mays, "Leukemia Risk from Neutrons," Health Physics, Vol. 34, pp. 353-360, 1978.
Schottenfeld, D., and Haas, J., "Carcinogens in* the Work place," CA-A Cancer Journal for Clinicians, Vol. 29, No. 3, May-June 1979.
United Nations Scientific Committee on the Effects of Atomic Radiation, 1977, Sources and Effects of Ionizing Radiation, Report to the General Assembly, UN Publica tion No. E.77.IX.I, 1977.
Upton, Arthur C., "Radiation from Nuclear Power Exagger ated," New England Journal of Medicine, VoL 302, pp. 1205
1206, May 22, 1980.
World Health Organization, Health Implications of Nuclear Power Production, Report of a %orking Group, December 1975.
8.29-15
VALUE/IMPACT STATEMENT
1. PROPOSED ACTION
1. 1 Description All NRC licensees are required to provide appropriate radia tion protection training for all permanent and transient person nel who work in restricted areas (§ 19.12 of 10 CFR Part 19).
A clear and reasonable assessment of the biological risks asso ciated with occupational radiation exposure is essential to effective radiation protection training. The proposed action is to provide instructional material in a suitable form describing and estimating the risks from exposure to radiation. The instructional material will be suitable for use in licensee training programs and will represent an acceptable method of complying with part of the existing training requirements.
1.2 Need for Proposed Action One common element of those occupational areas encom passed by NRC licensing activity is worker exposure to ionizing radiation and the biological risks from exposure. Union repre sentatives have expressed a dissatisfaction with the way in which these risks have been explained to the worker by the licensee. In addition, they feel the NRC has a responsibility to make its position on the controversial issue of radiation risk clear to the worker and the publi
c. A meeting of NRC
staff and union representatives was held on November 28,
1978, during which this matter was discussed. A transcript of the meeting is available from the Public Document Room.
The Environmental Protection Agency (EPA)
has published recommendations concerning radiation protection for public comment and, in conjunction with other govern ment agencies, will be holding public hearings on radiation risk and dose limits. This guide reflects current and proposed EPA guidance and will be helpful to workers and worker groups interested in understanding current discussion on the issues of risk-and dose limits.
1.3 Value/Impact of Proposed Action
1.3.1 NRC Operations Instructional material on radiation risk written at a level and scope understandable to the worker should contribute to increased confidence, on the part of the worker, in the NRC in general. A better understanding of the risk should elicit more worker cooperation with NRC-enforced safety programs. Impacts of the development of instructional material on risk include task completion manpower cost, estimated to be 0.2 person-year, and printing costs of approximately $400.00.
1.3.2 Other Government Agencies Agreement States whose licensing regulations include radiation protection training requirements may benefit from the availability of an NRC guide on radiation risk suitable for inclusion in those training programs. The guide was reviewed and distributed to agreement states by the Office of State Programs. Comments have been received from the EPA and the Bureau of Radiological Health.
1.3.3 Industry Providing a reasonable and understandable statement on worker risk should facilitate industry efforts to provide effective safety training and to better achieve as low as is reasonably achievable (ALARA) objectives. Minimal impact is expected in the form of additional cost of training programs since training requirements already exist. Comments from unions and industry in the development of instructional material on risk were encouraged. Numerous public comment letters were received from industry and three meetings were held with worker groups to review the draft guide.
1.3.4 Workers The proposed action should improve worker protection in that reasonable understanding of radiation risk is essential to the development of safe working practices. The staff believes that an objective discussion of radiation risk may in fact reduce "over concern" and also eliminate "under concern" on the part of some workers. If improved training results in a wider recognition and respect for radiation aL
an industrial hazard, more attention will be given to protective procedures and a. reduction in individual and collective dose should result.
1.3.5 Public Nuclear workers are also members of the public and are generally residents of the area where facilities are located.
Having a better-informed public should result in a wider range of participation in local decisionmaking concerning nuclear development. Improved training implies the added benefit of increased plant safety, thereby decreasing the probability of accidents that could involve the public.
1.3.6 Decision on Proposed Action The NRC should develop and provide instructional material concerning risk from occupational radiation exposure.
2. TECHNICAL APPROACH
The technical approach proposed is to develop instruc tional material concerning risks to the worker from occupa tional radiation exposure and to publish the material in a form that will receive the widest dissemination among NRC-licensed facilities. An alternative is to publish the findings of the proposed hearing on dose limits and assume the relevant information will filter down to the worke
r. It is
8.29-16
-1 I
- the feeling of the staff that a direct approach is required here.
3. PROCEDURAL APPROACH
The proposed action, to publish training material concern ing risks from occupational radiation exposure, the use of which would be recommended to all licensees, could be accomplished by several alternative methods. These include an NRC regulation requiring that specific training materials be used, a regulatory guide based on the existing § 19.12 that would provide an acceptable method for training on risks, an ANSI standard on training that could be adopted by a regulatory guide, and a NUREG report or a branch position paper.
3.1 Value/Impact of Procedural Alternatives An NR C regulation establishes general legal requirements, is costly and time consuming to prepare, and is not an appropriate vehicle for the specific and narrow objective proposed here. A regulation would be difficult to modify as new information on radiation risk is .developed. One advantage is that a regulation legally requires compliance.
In general, this approach is not considered cost effective in view of the objectives of the proposed action.
ANSI standards are generally intended as highly technical and advanced treatments of specialized areas of concern *to industry. A comprehensive technical review of risks from radiation would be of value but would not be suitable as instructional material at an introductory level for worker radiation protection training. Completion of an ANSI
standard and an endorsing regulatory guide would require several years and would be too costly. This approach is not considered cost effective in view of the proposed objectives.
A NUREG document would be an appropriate vehicle for a comprehensive discussion of radiation risk beyond the scope of what is proposed here. A regulatory position, however, is not established through publication of a NUREG
report. Since this proposal includes establishing an accept able method for compliance with elements of required training programs, a NUREG report is not suitable.
Branch position statements are intended as interim measures to be used when an immediate response is required.
They are usually superseded when a more permanent mode of guidance is developed.
A regulatory guide can be prepared at reasonable cost within a reasonable time period. The staff does not consider that revision of any existing regulatory guides could provide the instructicnal material intended here. Regulatory guides on training requirements are being developed but are specific to types of licensees such as Regulatory Guide 8.27, "Radiation Protection Training for Personnel at Light-Water-Cooled Nuclear Power Plants." The action proposed here has broad application to all licensees, as does Regulatory Guide 8.13,
"Instruction Concerning Prenatal Radiation Exposure."
3.2 Decision on Procedural Approach The staff concludes that a regulatory guide similar to Regulatory Guide 8.13 on the subject of worker instruction concerning risks from occupational radiation exposure should be published at this time.
4. STATUTORY CONSIDERATIONS
4.1 NRC Regulatory Authority Section 19.12 of 10CFR Part 19 establishes a legal requirement that all NRC licensees provide radiation protection training to personnel and that the training be commensurate with the potential risks from radiation exposure encountered by those personnel. The NRC is thus authorized to provide criteria for acceptable levels of training and to inspect for compliance with training require ments.
4.2 Need for NEPA Statement The action proposed here is to publish an instructional document on risks. This will occur after, and be in addition to, any major NRC action on retaining or modifying existing dose limits, based on planned public hearings.
Since at that time it would not constitute a major addition or change and would entail no effect on the environment, an environmental impact statement is not considered necessary.
5. RELATIONSHIP TO OTHER EXISTING OR PROPOSED
REGULATIONS OR POLICIES
Regulatory Guide 1.70, "Standard Format and Content of Safety Analysis Reports for Nuclear Power Plants,"
requires a commitment to appropriate radiation protection training. When next revised, it should include reference to this proposed action as an acceptable element of a licensee's training program.
This proposed guide is consistent with Regulatory Guide 8.8, "Information Relevant to Ensuring That Occupa tional Exposures at Nuclear Power Stations Will Be As Low As Is Reasonably Achievable." When next revised, Regulatory Guide 8.8 should include cross-reference to this proposed action.
This proposed action directly supplements Regulatory Guide 8.27 and will supplement and be referenced in other planned guides on training at other types of licensed facil ities, e.g., uranium fuel fabrication plants, uranium mills, medical institutions.
6. SUMMARY AND CONCLUSIONS
In summary, it is proposed that this regulatory guide be prepared and issued for the purpose of providing instruc tional material concerning assessment of risk from occupa tional radiation exposure.
8.29-17