ML003691559
| ML003691559 | |
| Person / Time | |
|---|---|
| Site: | Limerick (NPF-039, NPF-085) |
| Issue date: | 03/02/2000 |
| From: | Hutton J PECO Energy Co |
| To: | NRC/OCIO/IMD/RMB |
| References | |
| -RFPFR ERP-340 Rev 7 | |
| Download: ML003691559 (15) | |
Text
Station Support Department 10CFR50, Appendix E PECO ENERGY PECO Energy Company Nuclear Group Headquarters 965 Chesterbrook Boulevard Wayne, PA 19087-5691 March 2, 2000 Docket Nos. 50-352 50-353 License Nos. NPF-39 NPF-85 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555
Subject:
Limerick Generating Station, Units 1 & 2 Emergency Response Procedure Revision
Dear Sir/Madam:
Enclosed is the following procedure revision to the Emergency Response Procedures (ERPs) for Limerick Generating Station (LGS), Units 1 and 2. This procedure is required to be submitted within thirty (30) days of its revision in accordance with 10CFR50, Appendix E, and 10CFR50.4.
ERP-340, Revision 7, "Field Survey Group" Also, enclosed is a copy of a computer generated report index identifying the latest revisions of the LGS ERPs.
If you have any questions or require additional information, please do not hesitate to contact us.
Very truly yours, James A. Hutton Director - Licensing Attachments cc:
H. J. Miller, Administrator, Region I, USNRC (2 copies)
W. F. Kane, Director of Materials Safety & Safeguard, USNRC A. L. Burritt, USNRC Senior Resident Inspector, LGS (w/o enclosures)
Effective Date:
S1!aZ ERP-340 Rev.
7 Page 1 of 12 MES/ldt PECO ENERGY COMPANY LIMERICK GENERATING STATION EMERGENCY RESPONSE PROCEDURE ERP-340 FIELD SURVEY GROUP 1.0 RESPONSIBILITIES 1.1 Dose Assessment Coordinator (DAC) directs actions of Field Survey Team Members per ERP-300 until relieved by EOF Field Survey Group Leader.
1.2 Field Survey Team (FST) Members conduct field surveys.
2.0 INITIAL ACTIONS 2.1 DAC performs initial dispatch of Field Survey Teams per ERP-300-3.
2.2 Field Survey Team Members shall:
2.2.1 Obtain key to Site Management Building and Equipment Storage Locker from HP Field Office or TSC key locker.
2.2.2 Keep all dosimetry upon leaving protected area.
2.2.3 Report to the Site Management Building.
2.2.4 Contact DAC by phone (ext. 2620) and provide:
2.2.4.1 Name (HP and Driver) 2.2.4.2 Social Security Number (HP and Driver) 2.2.4.3 Team color designation (by kit selected) 2.2.5 Obtain Emergency Equipment:
2.2.5.1 Field Survey Kit 2.2.5.2 Emergency Dosimetry 2.2.5.3 Radio Equipment
- a.
Hand held radio
- b.
Two batteries
- c.
Antenna
- d.
Cigarette Lighter Adapter
ERP-340, Rev.
7 Page 2 of 12 MES/ldt 2.2.6 IF seal on Field Survey Kit is broken THEN obtain a sealed kit OR perform inventory per G0000579.
2.2.7 Perform Step 1 of ERP-340-2.
2.2.8 Notify DAC of any equipment that did not function correctly or is missing.
NOTE:
RELOCATE TO A MINIMUM OF 50 FEET FROM ANY SITE BUILDING PRIOR TO COMMUNICATION CHECK 2.2.9 Perform radio communication check with DAC.
NOTE:
CHANNEL 1 IS USED TO COMMUNICATE WITH THE FIELD SURVEY GROUP LEADER, CHANNEL 2 IS USED TO COMMUNICATE WITH OTHER FIELD SURVEY TEAMS.
2.2.9.1 IF vehicle has installed radio THEN use installed radio as primary communications.
- a.
Switch radio on
- b.
Perform radio check 2.2.9.2 IF vehicle dose not have installed radio but DOES have cigarette lighter, THEN use portable radio with charger.
- a.
Locate radio charger in vehicle
- b.
Plug charger into cigarette lighter
- c.
Put radio into charger face down
- d.
Place magnetic-based antenna on roof
- e.
Perform check using charger speaker and microphone 2.2.9.3 IF vehicle does not have an installed radio OR cigarette lighter, THEN use portable radio only.
- a.
Switch radio on
- b.
Adjust Squelch
- c.
Perform radio check 2.2.10 Ensure E-520/HP-270 or equivalent is operating at all times.
Proceed to initial location as directed.
2.2.11
ERP-340, Rev.
7 Page 3 of 12 MES/ldt 3.0 CONTINUING ACTIONS NOTE:
SECTION 3.1 IS TO BE PERFORMED ONLY IN THE EVENT THAT EOF DOSE ASSESSMENT IS NOT STAFFED TO PERFORM THESE FIELD SURVEY GROUP LEADER FUNCTIONS.
3.1 DAC shall:
3.1.1 Direct activities of the field survey teams.
3.1.1.1 Maintain communications with field survey teams 3.1.1.2 Record data on Appendix ERP-340-1 3.1.1.3 Provide status updates to the Field Survey Teams NOTE:
DRD READING X PROJECTED DOSE RATIO EQUALS ESTIMATED TEDE 3.1.1.4 Keep FST informed of projected dose ratio AND assist FST in using ratio to estimate TEDE dose.
3.1.2 Inform DATL of results from field
- surveys, particularly where:
3.1.2.1 Actual readings differ significantly from expected (projected) values.
3.1.2.2 Field dose rate equals or exceeds 250 mrem/hr.
3.1.2.3 Field radioiodine concentration equals or exceeds 6.5 X 10 N7 uCi/cc.
3.1.3 IF field radioiodine concentration exceeds 2 X 10 N8 uCi/cc THEN initiate team member DAC-hr tracking.
3.1.4 IF informed by FST that team MPC-hr exceeds 850 DAC hrs OR dose projections indicated that team MPC-hr may reach 950 DAC-hr THEN arrange for relief team dispatch OR initiate process for KI administration per ERP-600.
ERP-340, Rev. 7 Page 4 of 12 MES/ldt 3.1.5 IF informed by FST that team dose exceeds 75% of authorized level THEN arrange for relief field team dispatch OR initiate dose extension per ERP-650.
3.1.6 WHEN scan results of field air sample is available THEN calculate efficiency factor using the following equation AND transmit to teams.
Eff Factor
=
Estimated Concentration Actual Concentration 3.1.7 IF Field Survey Team members or vehicles become contaminated, THEN inform the Health Physics Team Leader.
3.1.8 WHEN directed by DATL THEN turnover FSGL duties to EOF FSGL using Appendix ERP-300-3.
3.2 Field Survey Team Members shall:
WARNING ALWAYS FOLLOW PECO ENERGY VEHICLE AND PERSONNEL SAFETY TECHNIQUES.
3.2.1 At each survey location:
3.2.1.1 Perform airborne, radiation and contamination survey, per ERP-340-2 step 2, unless directed otherwise by FSGL.
NOTE SURVEY NUMBER INCLUDES BOTH LETTER AND NUMBER.
LETTER IS DETERMINED BY TEAM DESIGNATED COLOR, NUMBER IS SEQUENTIAL BY TEAM.
EXAMPLE-SURVEY G-3 WOULD BE THE 3RD SURVEY PERFORMED BY THE GREEN TEAM.
3.2.1.2 Enter survey data on Field Survey Data Sheet, Appendix ERP-340-3.
3.2.1.3 Unless directed otherwise by FSGL proceed to a Low Background Area.
ERP-340, Rev. 7 Page 5 of 12 MES/1dt 3.2.2 While enroute to Low Background Area, transmit Data Items #1 through 5 from Field Survey Data Sheet Appendix ERP-340-3.
3.2.2.1 IF unable to contact FSGL by radio THEN:
- a.
Switch to Channel 2 and attempt a communications relay with another team
- b.
Telephone TSC at (610) 326-9860 OR EOF at (610) 380-3847 or 3848.
3.2.3 Upon arrival at Low Background Area:
NOTE THE AIR SAMPLE CALCULATIONS USED IN APPENDIX ERP-340-3, FIELD SURVEY DATA SHEET USE THE METHODOLOGY DESCRIBED IN HP-204.
3.2.3.1 Remove and count filter per HP-C-214.
3.2.3.2 Run air sampler for one minute with silver zeolite cartridge in place to purge cartridge of noble gases.
3.2.4 Field count smears per HP-C-211.
3.2.5 Field count iodine cartridge per HP-204.
3.2.6 Complete Field Survey Data Sheet.
3.2.7 Transmit Data Items #6 and 7 to Field Survey Group Leader.
3.2.8 Perform additional surveys as directed.
4.0 FINAL CONDITIONS 4.1 Survey all personnel and vehicles for radioactive contamination before returning to site.
4.2 Deliver all samples to Chemistry Group at R/W-217 OR as directed.
4.3 Deliver data sheets to DAC.
4.4 Inventory Field Survey Kit AND report results to Health Physics Team Leader in the TSC.
ERP-340, Rev.
7 Page 6 of 12 MES/ldt 5.0 APPENDICES 5.1 ERP-340-1, Field Survey Group Leader Data Sheet 5.2 ERP-340-2, Field Survey Team Member Checklist 5.3 ERP-340-3, Field Survey Data Sheet 6.0 SUPPORTING INFORMATION 6.1 Purpose 6.1.1 To provide guidelines for actions of Field Survey Group.
6.2 Criteria for Use 6.2.1 Field Survey Group shall be activated at Alert level or as determined by The Emergency Director.
6.3 Special Eguipment 6.3.1 Radio with battery packs and charger 6.3.2 Field survey kits 6.3.3 Vehicle 6.3.4 Emergency Dosimetry 6.4 References 6.4.1 6.4.2 6.4.3 6.4.4 6.4.5 6.4.6 6.4.7 6.4.8 6.4.9 HP-204 HP-C-214 Letter #JGF-89-11 Manual of Protective Actions for Nuclear Incidents (EPA 520-1-75-001-A January 1990)
NUREG/CR-3011 Dose Projection Considerations for Emergency Conditions at Nuclear Power Plant HP-C-211 ERP-600 ERP-300 ERP-650
ERP-340, Rev.
7 Page 7 of 12 MES/1dt 6.4.10 G0000579 6.4.11 EPA400-R-92-001, Oct.
1991, Manual of Protective Action Guides and Protective Actions for Nuclear Incidents.
6.5 Commitment Annotation 6.5.1 A.I Q0001944 6.5.2 OEAP A0370948-AE02 (Entire Procedure)
ERP-340, Rev.
7 Page 8 of 12 MES/ldt APPENDIX ERP-340-1 DATE FSGL FIELD SURVEY GROUP LEADER DATA SHEET DATA NUMBER SURVEY NUMBER 1
SURVEY LOCATION 2
TIME OF SURVEY 3
OPEN WINDOW mR/hr 4
CLOSED WINDOW 5*
GROSS SMEAR (cpm) 6 MASSLIN 6
IODINE CONCENTRATION 7*
jC i/cc DOSE RATIO 1
I
- IF CLOSED WINDOW(#5)
>250 OR IODINE CONCENTRATION(#7)
>6.5 x 10N7, NOTIFY DOSE ASSESSMENT COORDINATOR IMMEDIATELY
ERP-340, Rev.
7 Page 9 of 12 MES/ldt APPENDIX ERP-340-2 FIELD SURVEY TEAM MEMBER CHECK LIST (PAGE 1 of 2)
- 1.
BEFORE LEAVING SITE INSTRUMENT INVENTORY INSTRUMENT SERIAL CALIBRATI BATTERY
RESPONSE
CHECK-OFF TYPE NUMBER ON DUE CHECK CHECK RO-2A E-520 E-140N HP210T Radeco H 890C N/A A)
All Equipment accounted for and operable B)
Ensure all team members have Emergency Dosimetry and it is zeroed (0-1500mR and 0 5R DRD's)
C)
Notified DAC by phone X2620 D)
Radio communication check performed
- 1) Kit color designation team E)
Have been briefed on situation, etc.
F)
E520/HP270 is ON
- 2.
INSTRUCTIONS AT SURVEY LOCATION AND WHILE IN TRANSIT A)
Performed radiation survey while in transit to specified survey location B)
Notified DAC or FSGL at EOF of arrival and dose rate encountered C)
Start air sample
- 1)
Particulate filter and silver zeolite cartridge marked to indicate direction of air flow
- 2)
Flow Rate observed and recorded not to exceed 3 SCFM
- 3) 10 cubic feet minimum volume D)
Performed open/closed waist level survey using E-520/HP-270
ERP-340, Rev. 7 Page 10 of 12 MES/ldt E)
Perform gross masslin smear survey F)
Move to low background area G)
Transmit data points 1-5 from ERP-340-3
- 3.
AT LOW BACKGROUND COUNTING AREA A)
Remove and count particulate filter B)
Count Smear(s)
C)
Perform purge of silver zeolite cartridge D)
Calculate 1-131 Concentration E)
Transmit data points 6 and 7 from ERP-340-3 F)
Calculate DAC-hr G)
Complete Field Survey Data Sheet H)
When advised to return, monitor self, driver and vehicle for contamination and relay findings to FSGL I)
All samples turned over to Chemistry Group at Chemistry Control Point in Radwaste Enclosure J)
Turn over all completed forms to DAC for subsequent disposition.
ERP-340, Rev.
7 Page 11 of 12 MES/Idt APPENDIX ERP-340-3 FIELD SURVEY DATA SHEET (PAGE 1 of 2)
READ NUMBERED DATA TO FSGL/DAC W/O UNITS UNLESS DIRECTED OTHERWISE SURVEY NUMBER
(#1)
SURVEY LOCATION
(#2)
AIRBORNE SURVEY DATA SURVEY TIME
(#3)
Time Off Duration (Time Off Survey Time)
Initial Flow Rate cfm
+Final Flow Rate cfm
=
/2=Avg Flow Rate cfm Retention Factor (RF)=(20-Avg Flow Rate)
Volume (Duration x Avg Flow Rate)
RADIATION SURVEY DATA (WAIST HIGH)
OPEN WINDOW mR/hr (#4)
CLOSED WINDOW mR/hr
(#5)
CONTAMINATION SURVEY DATA GROSS SMEARS (MASSLIN)
LOCATION net cpm (#6)
LOCATION net cpm (#6)
AIRBORNE SURVEY CALCULATIONS Gross cpm Filter net cpm Filter Gross cpm Cartridge net cpm Cartridge ESTIMATE RADIOIODINE CONCENTRATION & MPC FRACTION Eff Factor = 1 unless FSGL notifies otherwise IODINE CONCENTRATION uCi/cc =
Net cpm Cartridge
= (#7)
(7.86 X 10-)(Volume)(RF)(Eff Factor)
DAC FRCTION = Estimated Radioiodine Concentration =
DAC 1-131 2.0 x 10N8 (Ref 6.5.1)
ERP-340, Rev.
7 Page 12 of 12 MES/ldt APPENDIX ERP-340-3 FIELD SURVEY DATA SHEET (PAGE 2 of 2)
(IF REQUESTED BY FSGL/DAC)
TEAM DOSE AND DAC-HR ESTIMATION Estimate time in plume(hr) x DAC Fraction
= Current DAC -
hr Previous DAC-hr
+ Current DAC-hr
= Team DAC-hr IF TEAM DAAC-HR EXCEEDS 850, NOTIFY FSGL IMMEDIATELY Completed by:
Date:
oHP TECH DRIVER
- 1.
Prev. Est.
- 2.
Prev.
DRD Rdng.
- 3.
Current DRD Rdng.
- 4.
Current Est. Proj.
Dose Ratio IF TOTAL DOSE EXCEEDS 75% OF CURRENT AUTHORIZED LEVEL, NOTIFY FSGL IMMEDIATELY HP TECH Current HP DRD Reading (3) _
Prey.
= Current HP Exp.
Current HP Exp _
x Current Est. Dose Ratio (4)
+ Current HP TEDE_=
total TEDE I&C TECH Current Driver DRD Rdng (3)
Prev. Driver DRD Rdng (2)
=Current Driver Exp._
Current Driver Exp__
x Current Est. Dose Ratio (4)
= Current Driver TEDE Previous Driver TEDE (1)
+ Current Driver TEDE
= Total TEDE
3/02/2000 PROCEDURE INDEX REPORT:
PECO ENERGY COMPANY LIMERICK GENERATING STATION FAC LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG DOC TYPE PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC TYPE ERR ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP PAGE PROCEDURE NUMBER ERP-C-1000 ERP-C-1000-1 ERP-C-1000-2 ERP-C-1000-3 ERP-C-1000-4 ERP-C-1100 ERP-C-1200 ERP-C-1200-1 ERP-C-1200-2 ERP-C-1210 ERP-C-1250 ERP-C-1250-1 ERP-C-1250-2 ERP-C-1250-3 ERP-C-1250-4 ERP-C-1300 ERP-C-1300-1 ERP-C-1300-2 ERP-C-1300-3 ERP-C-1300-4 ERP-C-1300-5 ERP-C-1300-6 ERP-C-1300-7 ERP-C-1300-8 ERP-C-1300-9 ERP-C-1310 ERP-C-1310-1 ERP-C-1310-2 ERP-C-1310-3 ERP-C-1310-4 ERP-C-1320 ERP-C-1320-1 ERP-C-1320-2 ERP-C-1320-3 ERP-C-1400 ERP-C-1400-1 ERP-C-1410 ERP-C-1410-1 CURR REV NBR TITLE 0005 EMERGENCY OPERATIONS FACILITY (EOF)
ACTIVATION/DEACTIVATION 0002 EOF ACTIVATION CHECKLIST 0003 EOF DEACTIVATION CHECKLIST 0000 EOF BUSINESS HOURS FIRST RESPONDER CHECKLIST 0000 EOF AFTER HOURS FIRST RESPONDER CHECKLIST 0003 EOF STAFF AUGMENTATION INCORPORATED INTO ERP-C-1250 0008 EMERGENCY REPSONSE MANAGER 0000 EMERGENCY RESPONSE MANAGER TURNOVER/BRIEFING FORM 0000 PROTECTIVE ACTION RECOMMENDATION WORKSHEET CANCELLED 0002 ASSISTANT EMERGENCY RESPONSE MANAGER (AERM)
CANCELLED 0003 EMERGENCY PREPAREDNESS COORDINATOR/EOF 0000 EMERGENCY POWER INSTRUCTIONS 0001 EMERGENCY PREPAREDNESS COORDINATOR INSTRUCTIONS FOR ASPEN BACKUP NOTIFICATION SYSTEM 0000 EMERGENCY PREPAREDNESS COORDINATOR INSTRUCTIONS TO STOP STAFFING 0000 ENERGENCY PREPAREDNESS COORDINATOR INSTRUCTIONS FOR SYSTEM RESET 0008 EMERGENCY OPERATIONS FACILITY (EOF)
DOSE ASSESSMENT TEAM LEADER 0002 DOSE ASSESSMENT TEAM LEADER INITIAL ACTIONS 0000 DOSE ASSESSMENT TURNOVER LIST 0003 PROTECTIVE ACTION RECOMMENDATION WORKSHEET 0000 OFFSITE SAMPLE ANALYSIS REQUESTS 0001 DETERMINATION OF PROTECTIVE ACTION RECOMMENDATIONS (PARS) 0001 DOSE ASSESSMENT GROUP INITIAL ACTIONS 0000 OBTAINING EPDS MET/RAD DATA 0000 USE OF MODE A/MODE B CDM 0001 OBTAINING MET DATA FROM NATIONAL WEATHER SERVICE 0003 EMERGENCY OPERATIONS FACILITY (EOF)
DOSE ASSESSMENT GROUP CANCELLED 0000 DOSE ASSESSMENT GROUP LEADER INITIAL ACTIONS CANCELLED 0000 OBTAINING MET DATA FROM NATIONAL WEATHER SERVICE CANCELLED 0000 OBTAINING EPDS MET/RAD DATA CANCELLED 0000 USE OF MODE A /
MODE B OF CDM CANCELLED 0005 EMERGENCY OPERATIONS FACILITY (EOF)
FIELD SURVEY GROUP LEADER 0002 FIELD SURVEY GROUP LEADER INITIAL ACTIONS 0001 FIELD SURVEY GROUP LEADER TURNOVER SHEET 0000 FIELD SURVEY GROUP LEADER DATA SHEET 0004 ENGINEERING SUPPORT TEAM 0002 ENGINEERING SUPPORT TEAM CHECKLIST 0002 CORE DAMAGE ASSESSMENT 0000 RADIOLOGICAL DATA EFFECTIVE RESP SYSTEM DATE GROUP NBR 04/21/99 04/21/99 04/21/99 04/21/99 04/21/99 09/14/94 11/02/98 LWE 09/14/94 10/24/95 10/24/95 11/02/98 09/14/94 04/02/98 09/14/94 09/14/94 11/02/98 04/10/98 09/23/94 11/02/98 09/23/94 11/02/98 04/10/98 03/26/97 03/26/97 09/12/97 03/26/97 03/26/97 03/26/97 03/26/97 03/26/97 04/10/98 04/10/98 03/26/97 09/23/94 11/02/98 11/02/98 09/09/98 09/14/94 1
3/o2/2QOO PROCEDURE INDEX REPORT:
PECO ENERGY COMPANY LIMERICK GENERATING STATION FAC LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG LG DOC TYPE PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC PROC TITLE PROC TYPE ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP ERP PROCEDURE NUMBER ERP-C-1410-2 ERP-C-1410-3 ERP-C-1410-4 ERP-C-1410-5 ERP-C-1410-6 ERP-C-1500 ERP-C-1500-1 ERP-C-1500-2 ERP-C-1900 ERP-C-1900-1 ERP-C-1900-2 ERP-C-1900-3 ERP-C-1900-4 ERP-C-1900-5 ERP-101 ERP-1O1 BASES ERP-106 ERP-110 ERP-120 ERP-140 ERP-200 ERP-200-1 APP ERP-230 ERP-300 ERP-330 ERP-340 ERP-350 ERP-360 ERP-370 ERP-400 ERP-410 ERP-420 ERP-430 ERP-440 ERP-500 ERP-600 ERP-620 ERP-630 ERP-640 ERP-650 PAGE 2
CURR REV NBR 0001 0001 0000 0001 0001 0005 0001 0001 0004 0000 0002 0002 0002 0002 0011 0000 0003 0030 0006 0009 0012 0010 0013 0021 0000 0007 0003 0003 0001 0012 0002 0002 0002 0002 0015 0012 0002 0003 0008 0009 HYDROGEN CONCENTRATION DATA CONTAINMENT RADIATION MONITOR DATA METAL WATER REACTION CANCELLED PERCENT OF FUEL INVENTORY AIRBORNE IN THE CONTAINMENT VS.
APPROXIMATE SOURCE AND DAMAGE ESTIMATE PROCEDURES FOR ESTIMATING FUEL DAMAGE BASED ON MEASURED 1-131 AND XE-133 CONCENTRATIONS LOGISTIC SUPPORT TEAM MESSAGE AND INFORMATION INSTRUCTIONS HELICOPTER LANDING INFORMATION RECOVERY PHASE IMPLEMENTATION RECOVERY PHASE IMPLEMENTATION FLOW CHART PEACH BOTTOM ATOMIC POWER STATION RECOVERY ACCEPTANCE CHECKLIST LIMERICK GENERATING STATION RECOVERY ACCEPTANCE CHECKLIST RECOVERY PLAN OUTLINE ASSESSMENT CONSIDERATIONS CLASSIFICATION OF EMERGENCIES LGS EAL TECHNICAL BASIS MANUAL WRITTEN
SUMMARY
NOTIFICATION EMERGENCY NOTIFICATION STATION EVACUATIONS STAFFING AUGMENTATION EMERGENCY DIRECTOR (ED)
RESPONSE
EMERGENCY NOTIFICATION MESSAGE FORM OPERATIONS SUPPORT CENTER (OSC)
DIRECTOR TSC/MCR DOSE ASSESSMENT TEAM USE OF NORTH STACK-DOSE RATE TO ESTIMATE RELEASE SOURCE TERM CANCELLED INCORPORATED INTOERP-300 APP.1O FIELD SURVEY GROUP RADIOACTIVE LIQUID RELEASE CANCELLED ADJUSTMENT OF WIDE RANGE GAS MONITOR CONVERSION FACTORS USE OF RMMS FOR DOSE ASSESSMENT CANCELLED CHEMISTRY SAMPLING AND ANALYSIS TEAM SAMPLE PREPARATION AND HANDLING OF HIGHLY RADIOACTIVE LIQUID SAMPLES SAMPLE PREPARATION AND HANDLING OF HIGHLY RADIOACTIVE PARTICULATE FILTERS AND IODINE CARTRIDGES SAMPLE PREPARATION AND HANDLING OF HIGHLY RADIOACTIVE GAS SAMPLES OFF-SITE ANALYSIS OF HIGH ACTIVITY SAMPLES SECURITY TEAM HEALTH PHYSICS TEAM PLANT SURVEY GROUP CANCELLED -
NO REPLACEMENT VEHICLE AND EVACUEE CONTROL GROUP EMERGENCY RESPONSE FACILITY HABITABILITY ENTRY FOR EMERGENCY REPAIR AND OPERATIONS EFFECTIVE RESP SYSTEM DATE GROUP NBR 09/09/98 09/09/98 09/09/98 09/09/98 09/09/98 04/02/98 10/24/95 10/24/95 11/02/98 06/28/93 04/02/98 04/02/98 04/02/98 12/28/99 09/14/99 LWE 09/16/99 11/22/95 LWE 11/04/99 LWE 11/14/97 LWE 02/03/98 LWE 10/05/98 LWE 10/05/98 LWE 05/14/99 LWE 10/18/99 LWE 11/14/94 LWE 03/01/00 LWE 11/10/94 LWE 10/18/99 LWE 11/10/94 LWE 09/28/98 LWE 09/28/98 LWE 09/28/98 LWE 09/28/98 LWE 03/29/95 LWE 09/24/97 LWE 05/19/98 LWE 05/02/95 LWE 03/29/95 LWE 04/17/99 LWE 04/17/99 LWE
3/02/2Ž0O PROCEDURE INDEX REPORT:
PECO ENERGY COMPANY LIMERICK GENERATING STATION CURR REV PROCEDURE NUMBER NBR TITLE ERP-660 0006 DISTRIBUTION OF THYROID BLOCKING TABLETS ERP-700 0014 TECHNICAL SUPPORT TEAM ERP-800 0018 MAINTENANCE TEAM END OF REPORT **
EFFECTIVE DATE 04/17/99 10/05/98 09/14/99 RESP SYSTEM GROUP NBR LWE LWE LWE FAC LG LG LG DOC PROC TYPE TYPE PROC ERP PROC ERP PROC ERP PAGE 3