LIC-04-0001, December 2003 Monthly Operating Report for Fort Calhoun Station

From kanterella
Jump to navigation Jump to search
December 2003 Monthly Operating Report for Fort Calhoun Station
ML040210736
Person / Time
Site: Fort Calhoun Omaha Public Power District icon.png
Issue date: 01/08/2004
From: Ridenoure R
Omaha Public Power District
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
LIC-04-0001
Download: ML040210736 (2)


Text

OmahaPublic PmwrDistict 444 South 16th Street Afall Omaha NE 68102-2247 January 8, 2004 LIC-04-0001 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001

Reference:

Docket No. 50-285

SUBJECT:

December 2003 Monthly Operating Report (M1OR)

Pursuant to Fort Calhoun Station (FCS) Unit No. I Technical Specification 5.9.1.c, Omaha Public Power District (OPPD) submits the attached MOR for December 2003. No commitments are made to the NRC in this letter.

If you have any questions, please contact Mr. Erick Matzke at (402) 533-6855.

Sincerely, IM/epm liment c: B. S. Mallett, NRC Regional Administrator, Region IV A. B. Wang, NRC Project Manager J. G. Kramer, NRC Senior Resident Inspector INPO Records Center j7?c$ (4 Employment with Equal Opportunity

LIC-04-0001 Attachment OPERATING DATA REPORT DOCKET NO. 50-285 UNIT NAME Fort Calhoun Station DATE January 2, 2004 COMPLETED BY E. P. Matzke TELEPHONE (402) 533-6855 REPORT PERIOD: December 2003 Design Electrical Rating (IN'e-Net): 478 lMaximum Dependable Capacity (Ml'e-Net): 478 MONTH YR-TO-DATE CIJUIJLATIVE Number of Hours Reactor was Critical: 744 7,626 214,868 Number of Hours Generator was On-line: 744 7,597 213,525 Unit Reserve Shutdown Hours: 0 0 0 Net Electrical Energy Generated (MN 'li): 365,757 3,510,073 92,526,103 UNIT SHUTDOWNS IDate~~ ~ ~ yeMethod Type Duration I Shutting of Cause & Corrective No. F: Forced Down Action Comments I Scheduled 5: (yylnim.Idd) (urs) R n Reactor (1) Reason: (2) lethod:

A-Equipment Failure (Explain) 1-Manual B-Maintenance or Test 2-M1anual Trip/Scram C-Refueling 3-Automnatic Trip/Scram D-Regulatory Restriction 4-Continuation E-Operator TrainingfLicense Examination 5-Other (Explain)

F-Administrative G-Operational Error (Explain)

Il-Other (Explain)

OPERATIONS

SUMMARY

Fort Calhoun Station operated at a nominal 100 percent power for the entire month of December.