LG-22-069, Registration of Spent Fuel Storage Casks Used at Limerick Generating Station

From kanterella
Jump to navigation Jump to search
Registration of Spent Fuel Storage Casks Used at Limerick Generating Station
ML22235A112
Person / Time
Site: Limerick, 07201032  Constellation icon.png
Issue date: 08/23/2022
From: Gillin M
Constellation Energy Company
To:
Document Control Desk, Office of Nuclear Material Safety and Safeguards, Office of Nuclear Reactor Regulation
References
LG-22-069
Download: ML22235A112 (2)


Text

Constellation

10 CFR 72.212 LG-22-069

August 23, 2022

ATTN: Document Control Desk Director, Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

Limerick Generating Station, Units 1 and 2 Renewed Facility Operating License Nos. NPF-39 and NPF-85 NRC Docket Nos. 50-352, 50-353, and 72-065

Subject:

Registration of Spent Fuel Storage Casks Used at Limerick Generating Station

In accordance with 10 CFR 72.212, "Conditions of general license issued under §72.210,"

paragraph (b)(2), Constellation Energy Company, LLC is registering, with the NRC, the use of two casks under the general license to store spent fuel at Limerick Generating Station.

The following information is provided in accordance with 10 CFR 72.212(b)(2).

Licensee Name: Constellation Energy Company, LLC

Licensee Address: Limerick Generating Station 3146 Sanatoga Road Pottstown, PA 19464

Renewed Reactor License NPF-39 and NPF-85 and Docket Numbers:

Reactor Docket Numbers: 50-352 and 50-353

Independent Spent Fuel 72-065 Storage Installation Docket Number:

Contact Name and

Title:

Laura Lynch Manager - Regulatory Assurance

Cask Certificate Number: No. 1032, Amendment No. 1, Revision No. 1 Cask Model Number: HI-STORM FW MPC-89 The following information is for the casks that were loaded.

Service Date: 7/26/2022 Cask Identification Number: 00-S114/MPC-005 HI-STORM Identification Number: 00-S114/HISTORM-005

Service Date: 8/3/2022 Cask Identification Number : 00-S114/MPC-006 HI-STORM Identification Number : 00-S114/HISTORM-006

If you have any question concerning this report, please contact Laura Lynch at 610-718-3400.

Respectfully,

Michael F. Gillin Site Vice President - Limerick Generating Station Constellation Energy Generation, LLC

cc: Administrator Region 1 -USNRC USNRC Senior Resident Inspector, LGS NRC Project Manager, NRC - Limerick Generating Station (LGS)

Decommissioning Branch Chief - NRC Region I D. Lafleur, Commonwealth of Pennsylvania, DEP