LD-89-087, Responds to NRC Re Violations Noted in Insp Rept 70-1100/89-01.Corrective Action:Procedures Revised to Be Consistent W/Nrc Interpretation of License Requirements

From kanterella
(Redirected from LD-89-087)
Jump to navigation Jump to search
Responds to NRC Re Violations Noted in Insp Rept 70-1100/89-01.Corrective Action:Procedures Revised to Be Consistent W/Nrc Interpretation of License Requirements
ML20245G224
Person / Time
Site: 07001100
Issue date: 08/02/1989
From: Scherer A
ABB COMBUSTION ENGINEERING NUCLEAR FUEL (FORMERLY
To: Knapp M
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
LD-89-087, LD-89-87, NUDOCS 8908150280
Download: ML20245G224 (1)


Text

-__

u.

i COIRBUSTION ENGINEERING August 2,1989 LD-89-087 Docket No. 70-1100 License No. SNM-1067 Dr. Malcolm R. Knapp, Director Division of Radiation Safety and Safeguards U.S. Nuclear Regulatory Commission Region I 475 Allendale Road King of Prussia, Pennsylvania 19406

Subject:

Response to Notice of Violation (NRC Inspection Report 70-1100/89 ')1)

Reference:

Letter, M. R. Knapp (NRC) to P. L. McGill (C-E),

dated July 25, 1989

Dear Dr. Knapp:

Combustion Engineering has reviewed the Reference letter with regard to sealing B-25 low level radioactive waste shipping containers.

Please be advised that our procedures have been revised to be consistent with the Nuclear Regulatory Commission interpretation of license requirements.

As of July 12, 1989, procedures were issued requiring the lids on B-25 containers on the waste storage pad adjacent to Building 21 to be secured. In addition, all B-25 containers already on the waste storage pad had their lids secured. B-25 containers on the waste storage pad are also sealed with a Type E cup seal whose purpose is the detection of tampering.

If you have any questions concerning thic matter, please do not hesitate to call me or Mr. J. F. Conant of my staff at (203)285-5002.

Very truly yours, COMBUSTION ENGINEERING, INC.

" AA'///

7,

A. E herer Director Nuclear Licensing pl7 AES:Jeb cc:

R. Bellamy (NRC - Region I)

D. McCaughey (NRC) t o J. Roth (NRC - Region 1)

Power Systems 1000 Prospect Hill Road (203) 688-1911 Combustion Engineenng. Inc.

Post Office Box 500 Telex: 99297 Windsor, Connecticut 06095-0500 8908150280 890802 PDR ADOCK 07001100 C

PDC