Text
r C E PIw:r Syst:ms T el. 203/f>88 - 1911 Combustion Engineenng soc TMex 99297 1000 Prospect Hill Road Windsor. Connechcut 06095 H SYSTEMS POWER Docket No.: STN-50-470F September 8, 1982 LD-82-078 Mr. Darrell G. Eisenhut, Director Division of Licensing V. S. Nuclear Regulatory Commission Washington, D. C.
20555
Subject:
CESSAR SER Confirmatory item Number 9
Dear Mr. Eisenhut:
Enclosed is Combustion Engineering's (C-E's) report responding to Confirmatory item 9 of the CESSAR SER. The report presents our evaluation of a natural circulation cooldown with controlled voiding in a System 80 NSSS. C-E has concluded that the probability of system or component failures that would require a rapid natural circulation cooldown and subsequent voiding remains remote and that the operator has sufficient instrumentation to perform a rapid natural circulation cooldown with controlled void formation.
This report should close out Confirmatory Item Number 9.
If any questions arise concerning this report, please contact me or Mr. G. A.
Davis of my staff at (203)688-1911 Extension 2803.
Very truly yours, COMBUSTION ENGINEERING, INC.
T. L M cnerer Director Nuclear Licensing AES:ctk Enclosure 8209100168 820908 PDR ADOCK 05000470 E
>