L-91-116, Forwards Request for Addl Info to C-E Topical Rept CENPD-269-P,Rev 1-P, Extended Burnup Operation of C-E PWR Fuel

From kanterella
(Redirected from L-91-116)
Jump to navigation Jump to search

Forwards Request for Addl Info to C-E Topical Rept CENPD-269-P,Rev 1-P, Extended Burnup Operation of C-E PWR Fuel
ML17223B169
Person / Time
Site: Saint Lucie 
Issue date: 04/17/1991
From: Sager D
FLORIDA POWER & LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
L-91-116, TAC-75947, NUDOCS 9104240345
Download: ML17223B169 (9)


Text

ACCELERATED DISTRIBUTION DEMONSTRATION SYSTEM r

REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9104240345 DOC.DATE: 91/04/17 NOTARIZED: NO FACIL:50-389 St. Lucie Plant, Unit 2, Florida Power

& Light, Co.

AUTH.NAME AUTHOR AFFILIATION SAGER,D.A.

Florida Power 6 Light Co.

RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Forwards request for addi info to C-E topical rept CENPD-269-P,Rev 1-P, "Extended Burnup Operation of C-E PWR Fuel."

DISTRIBUTION'CODE: A001D COPIES RECEIVED:LTR ENCL SIZE:

TITLE: OR Submittal:

General Distribution NOTES:

DOCKET 05000389 RECIPIENT ID CODE/NAME PD2-2 LA NORRIS,J INTERNAL: ACRS NRR/DET/ESGB NRR/DST 8E2 NRR/DST/SICB 7E NUDOCS-ABSTRACT OGC/HDS3 RES/DSIR/EIB EXTERNAL: NRC PDR COPIES LTTR ENCL 1

1 2

2 6

6 1

1 1

1 1

1 1

1 1

0 1

1 1

1 RECIPIENT ID CODE/NAME PD2-2 PD REG FILE 01 NSIC NRR/DET/ECMB 9H NRR/DOEA/OTSB11 NRR/DST/SELB 8D NRR/DST/SRXB 8E COPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

1 1

0 1

1 1

1 NOTE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK ROOM Pl-37 (EXT. 20079) TO ELIMINATEYOUR NAMEFROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 24 ENCL 22

P.Q. Bex 128, Ft. P>cree, FL 34954-0128 L-91-116 APR i 7 1$9i U.S. Nuclear Regulatory Commission Attn:

Document Control Desk Washington, DC 20555 Gentlemen:

Re:

St. Lucie Unit 2 Docket No. 50-389 Request for Additional Information Extended Burnu 0 eration of Combustion En ineerin PWR Fuel TAC No. 75947 By letter dated January 25,

1990, Florida Power and Light (FPL) requested
that, the Nuclear Regulatory Commission Staff review Combustion Engineering (CE) Topical Report CENPD-269-P, Revision 1-P, "Extended Burnup Operation of Combustion Engineering PWR Fuel,"

dated July 1984, for applicability to St. Lucie Unit 2.

To aid in its review, the Staff requested additional information in a letter dated February 13, 1991.

FPL is providing its response to the Staff's question in Attachment One to this letter.

Should there be any questions, or if additional information is needed, please contact us.

Very truly yours, D.A.

S er Vice r sident St.

Lu ie Plant Attachment DAS:JMP:kw cc:

Stewart D. Ebneter, Regional Administrator, Region II, USNRC Senior Resident Inspector, USNRC, St. Lucie Plant DAS/PSL N409 9

PD P

23(., 'f Pg 104240345 910417 I

I AGOCK 05000389 PDR an FPL Group company

1 l

p",

I I

~

Ã

~

P

//

i.%l-l

,l

Attachment One L-91-116 Page 1 of 5 ATTACHMENT ONE Request for Additional Information "Extended Burnup Operation of Combustion Engineering PWR Fuel" (CENPD-269-P)

Florida Power and Light (FPL) provides the following information in response to the Nuclear Regulatory Commission Staff question concerning clad corrosion data for St. Lucie Unit 2 fuel rods.

NRC uestion:

The ANO-2 request for a 1-pin burnup limit of 60 MWd/kgU (CENPD-386-P) indicated that the cladding oxidation model and associated data were to be provided on a reactor-specific basis;

however, no data or analysis model is presented in the subject topical report specifically for St. Lucie Unit 2.

What cladding corrosion data are used as the basis for the cladding corrosion model for St.

Lucie Unit 2? If the corrosion data used are not from St. Lucie Unit 2 fuel rods, please provide an explanation of why this data is applicable; i.e.,

provide a

comparison of reactor coolant temperatures, chemistry and corrosion data, and how the model is developed and applied to provide conservative and bounding analyses.

FPL Res onse:

Cladding corrosion data for ANO-2 were used as the basis for the cladding corrosion model for St. Lucie Unit 2 as described in Combustion Engineering Topical Report CENPD-269-P, Revision 1-P, "Extended Burnup Operation of Combustion Engineering PWR Fuel."

Cladding waterside corrosion is dependent on a number of factors that are specific to each operating plant.

Thus, an evaluation of high burnup waterside corrosion should be performed on a plant-by-plant basis.

The factors that are known to affect corrosion fall into two basic categories:

(1) the thermal, or temperature effects

category, and (2) the chemistry effects category.

A tabulated comparison of the key parameters for St. Lucie Unit 2 and ANO-2 is provided in Table One of this attachment.

Thermal and chemistry effects on waterside corrosion in the St. Lucie Unit 2 core have been considered.

Thermal effects experienced by St. Lucie Unit 2 fuel rods are less aggressive than those experienced at ANO-2 with respect to cladding

Attachment One L-91-116 Page 2 of 5 corrosion.

Coolant chemistry effects for St.

Lucie Unit 2

fuel cannot be judged to be less aggressive than those experienced by ANO-2 since data are not available to quantitatively evaluate the impact of the difference in chemistry effects.

It should also be noted, however, that a

maximum oxide thickness on the order of 120 microns or less, as presented in the topical report, should not impair the thermal and mechanical performance of the St.

Lucie Unit 2

fuel rods and should therefore be an acceptable thickness for operation of St. Lucie Unit 2 at a maximum fuel rod burnup of 60 MWd/kgU.

A discussion of the temperature and chemistry effects follows.

Thermal or Tem erature Effects The St. Lucie Unit 2 core axial and radial peaking factors are comparable to ANO-2.

As a result, the St. Lucie Unit 2 linear heat rate distributions (and the resulting surface heat flux distributions) over the active fuel length will always be lower than those experienced at ANO-2.

When the lower linear heat rates are considered in combination with a lower coolant inlet temperature, lower local coolant and cladding surface temperatures will be present everywhere in the reactor core.

Based on these comparisons, it is concluded that the thermal effects experienced in the St.

Lucie Unit 2 core are less aggressive with respect to corrosion than those encountered in the ANO-2 core.

The achievement of a fuel rod maximum burnup of 60 MWd/kgU at St.

Lucie Unit 2 would require a longer total irradiation time, perhaps an additional cycle of operation, than for ANO-2 because of the inherently lower linear heat rates.

Additionally, corrosion on the fuel rods that achieve comparable burnups will tend to be less severe when the power level is lower during irradiation.

Therefore, based upon this consideration, as well as that cited above, the St. Lucie Unit 2 corrosion projection due to thermal effects to 60 MWd/kgU is expected to be bounded by the ANO-2 corrosion projection to 60 MWd/kgU.

Chemistr Effects Chemistry effects are primarily characterized by coolant chemistry parameters, but may include the Zircaloy cladding

material, as alloying elements are known to affect corrosion.

However, the trend to improve the cladding material corrosion behavior is expected to continue and need not be considered here.

Attachment One L-91-116 Page 3 of 5 With respect to primary coolant chemistry, lithium content in the coolant is generally considered to be the most. important parameter affecting cladding corrosion.

A detailed review of the lithium chemistry history from ANO-2 during the cycles when fuel was measured for corrosion behavior indicated that the lithium chemistry guidelines in existence at the time (i.e.,

lithium level between 1

and 2

ppm) were generally followed.

Thus, the ANO-2 corrosion data base is associated with five (5) cycles of exposure with primary coolant lithium between 1 and 2

ppm.

The first batch of St.

Lucie 2 fuel assemblies which is being considered for extended burnup operation was in its first cycle during St. Lucie Unit 2 Cycle 5.

An elevated lithium chemistry program was implemented in Cycle 5 to reduce out of core radiation fields.

Initially, the lithium concentration was maintained at 3.5 ppm for approximately the first half of Cycle 5 until a pH of 7.4 was reached.

The lithium concentration was then gradually reduced to below 2

ppm over the remainder of the cycle.

A modified lithium chemistry program supported by EPRI has been implemented starting in Cycle 6, which significantly reduces the operating time above 2

ppm to less than five percent of the Cycle.

Even though it cannot be conclusively stated that the ANO-2 database will bound the expected oxide thickness evolution at St. Lucie 2, the lithium chemistry is being maintained under a controlled program, and the period of time spent outside of this database for cycles 6 and beyond is expected to be less than five percent.

a t~

a at Attachment One L-91-116 Page 4 of 5 TABLE ONE COMPARISON OF CORE GEOMETRIC AND OPERATING PARAMETERS St. Lucie Unit 2 and ANO-2 Corrosion Parameter St. Lucie Unit 2 ANO-2 Reactor

Power, MW, umber of fuel assemblies Core average linear eat generation rate (LHGR) I kw/ft ssembly pitch, in.

Fuel rod diameter, in+

Fuel rod pitch, in.

atrix hydraulic diameter, in.

Core flow area, ft.'tive fuel length, in.

Core flow rate, lb /hr-ft Core average surface eat flux, BTU/hr-ft'oolant inlet temperature, degrees F

Coolant outlet temperature, degrees F

2700 217 4.7 8.180 0.382 0.506 0 ~ 4714 54.39 136.7 2.5xlO'.61x10'49 600 2815 177 5.6

8. 180 0.382 0.506
0. 4714 44.36 150.0 2.7xl06 1.92xlO'55 613 Discussion Thermal effects on waterside corrosion can be characterized by an evaluation of specific core geometric and operating parameters as

Attachment One L-91-116 Page 5 of 5 tabulated above.

Values for each parameter are provided for St.

Lucie Unit 2

and ANO-2 for comparision purposes.

Operating parameters are at an assumed 100% power level.

The tabulated parameters are not independent.

Core average linear heat generation rate (LHGR) and surface heat flux are dependent on core power, the number of fuel rods, and the active fuel length; similarly, outlet temperature is dependent on inlet temperature, core power and flow rate.