CC~LERATED DIST BUTION DEMONSTRATION SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
ACCESSION NBR:9010090192 DOC.DATE: 90/09/28 NOTARIZED: YES FACIL:50-250 Turkey Point Plant, Unit 3, Florida Power and Light C 50-251 Turkey Point Plant, Unit 4, Florida Power and Light C 50-335 St. Lucie Plant, Unit 1, Florida Power S Light. Co.
50-389 St. Lucie Plant, Unit 2, Florida Power 6 Light Co.
AUTH.NAME AUTHOR AFFILIATION BOHLKE,W.H.
Florida Power
& Light Co.
RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)
DOCKET 05000250 05000251 05000335 05000389 R
SUMECT: Forwards response to Generic Ltr 90-03 re relaxation of staff position in GL 83-28,Item 2.2 Part 2.
DISTRIBUTION CODE:
A016D COPIES RECEIVED:LTR ENCL SIZE:
TITLE: Generic Ltr 90-03, Relaxation of Staff Position xn GL-83-28, NOTES:
Item 2.2 D
RECIPIENT ID CODE/NAME PD2-2 LA PM-LA BARGE,D INTERNAL: ACRS NRR/DST/SICB 7E OC/J g5 EXTERNAL: NRC PDR COPIES LTTR ENCL 1
1 1
1 6
6 1
1 1
0 1
1 1
1 RECIPIENT ID CODE/NAME PD2-2 PD NRR/DST 8E2 NRR/LA BARGE,D OGC/HDS2 NSIC COPIES LTTR ENCL 1
1 1
1 1
1 1
0 1
1 D
D D
NOTE TO ALL"RIDS" RECIPIENTS:
PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM P 1-37 (EXT. 20079) TO ELIMINATEYOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!
TOTAL NUMBER OF COPIES REQUIRED:
LTTR 17 ENCL 15 D
D
I
P.O. Box14000, Juno Beach, FL 33408-0420 SEPTEMBER 2 8 1999 L-90-336 10CFR50-54(f)
U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C.
20555 Gentlemen:
Re:
St. Lucie Units 1 and 2
Docket Nos.
50-335 and 50-389 Turkey Point Units 3 and 4
Docket Nos.
50-250 and 50-251 Generic Letter No. 90-03, Relaxation of Staff Position in Generic Letter 83-28, Item 2.2 Part 2 "Vendor Interface for Safet -Related Com onents" NRC Generic Letter No.
90-03, Relaxation of Staff Position in Generic Letter 83-28, Item 2.2 Part 2 "Vendor Interface for Safety-Related Components",
issued March 20, 1990, provided the elements that the NRC staff has concluded should be contained in a vendor interface program for safety-related components.
Florida Power and Light Company's response to the recommendations in GL 90-03 for St.
Lucie Units 1 and 2 and Turkey Point Units 3 and 4 is attached.
Should there be any questions, please contact us.
Very truly yours, W. H. Bohlke Vice President Nuclear Engineering and Licensing WHB/lef Attachment cc:
Stewart D. Ebneter, Regional Administrator, Region II, USNRC Senior Resident Inspector, USNRC, St. Lucie Plant Senior Resident Inspector, USNRC, Turkey Point Plant 90i0090i92 90092S PDR 4DOCK 05000250 P
kT J
r A, p$ p
STATE OF FLORIDA
)
)
ss.
COUNTY OF PALM BEACH
)
W. H. Bohlke being first duly sworn, deposes and says:
That he is Vice President Nuclear En ineerin and Licensin of Florida Power
& Light Company, the Licensee herein; That he has executed the foregoing document; that the statements made in this document are true and correct to the best of his knowledge, information and belief, and that he is authorized to execute the document on behalf of said Licensee.
W. H. Bohlke Subscribed and sworn to, before me this day of SVM&k~, 196'>.
NOTARY PUBLIC STATE OF FI,ORIDA NY CONNISSION EXP. OCT.30,199I BONOEO TNRU OENERAL INS U 'iOTARp. PUBLIC, in and for the County of Palm Beach,'tate of Florida TI g
I Ilg.I-
, My Commission expires
4
'1
/
'E J
h tl ~
il
<<+l I
1
/,
4
Attachment
Response
to Generic Letter 90-03 Generic Letter 90-03 identifies two specific areas requiring response.
To summarize, the NRC staff concluded that an adequate vendor interface program should include:
a ~
A program with the NSSS vendor as described in VETIP, which covers all safety-related components within the NSSS scope of supply.
This.:program should include provisions for assuring receipt by the licensee/applicant of all technical information provided by the NSSS vendor.
Response
Florida Power and Light Company (FPL) actively participated in the Nuclear UtilityTask Action Committee (NUTAC) on Generic Letter 83-28, "Required Actions Based on Generic Implications of Salem ATWS Events" Section 2.2.2 for the specific purpose of defining an appropriate vendor interface program.
A result of the NUTAC efforts was the development of the Vendor Equipment Technical Information Program (VETIP) 'as described in Institute of Nuclear Power Operations (INPO) Report 84-10, issued in March 1984. The FPL program for safety-related components within the NSSS scope of supply is in line with the VETIP as developed by NUTAC.
The FPL program includes an established NSSS Vendor Interface Program (Combustion Engineering for St.
Lucie Units 1
and 2,
Westinghouse for Turkey Point Units 3 and 4) which assures that the most current NSSS vendor information is provided to FPL in information bulletins.
FPL provides feedback to the NSSS vendor in the form of a signed receipt for technical information'received in these bulletins.
b.
A program of periodic contact with vendors of other key safety-related components not included in (a) above.
Response
FPL is establishing a program to assure that vendors of "other key safety-related components" are contacted on a periodic basis.
Vendors of the Diesel Generators, Auxiliary Feedwater
- Pumps, Safety-Related Batteries, Inverters and Battery Chargers, Essential Component Cooling Water Pumps, Safety-Related Electrical Switchgear and Safety-Related Non-Manual Valve Operators are considered "other key safety-related component" vendors.
This program will consist of periodic direct mailings with additional mailings and/or phone calls until a
response is received or all reasonable means of contact prove unsuccessful.
The contacts will be documented and filed for future reference.
This program will be in place by January 1,
1991.
R