L-88-274, Application for Amends to Licenses DPR-37 & NPF-16,deleting Containment Integrated Leak Rate Testing Methods in Favor of Improved Methods,Including Mass Point Method,Not Recognized in ANSI N45.4-1972.Fee Paid

From kanterella
(Redirected from L-88-274)
Jump to navigation Jump to search
Application for Amends to Licenses DPR-37 & NPF-16,deleting Containment Integrated Leak Rate Testing Methods in Favor of Improved Methods,Including Mass Point Method,Not Recognized in ANSI N45.4-1972.Fee Paid
ML17222A312
Person / Time
Site: Saint Lucie  
Issue date: 06/23/1988
From: Conway W
FLORIDA POWER & LIGHT CO.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
Shared Package
ML17222A313 List:
References
L-88-274, NUDOCS 8807010657
Download: ML17222A312 (6)


Text

ACCELERATED DIAIBUTION DEMONSTRATION SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

DOCKET.,g 05000335'5000389 NOTES:

ACCESSION NBR:8807010657 DOC.DATE: 88/06/23 NOTARIZED: YES FACIL:50-335 St. Lucie Plant, Unit 1, Florida Power 6 Light Co.

50-389 St. Lucie Plant, Unit, 2; Florida Power 6 Light Co.

AUTH.NAME AUTHOR AFFILIATION CONWAY,W.F.

Florida Power 6 Light Co.

RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Application for amends to Licenses DPR-37 6 NPF-16,deleting containment integrated leak rate testing methods as stated.

DISTRIBUTION CODE:

A017D COPIES RECEIVED:LTR I

ENCL J SIZE:5+

I TITLE: OR Submittal:

Append J Containment Leak Rate Testing RECIPIENT ID CODE/NAME PD2-2 LA TOURIGNY,E

'COPIES LTTR ENCL 1

0 1 1'k RECIPIENT "'" 'OPIES ID,CODE/NAME LTTR ENCL PD2-2 PD 5

5 A

INTERNAL: ACRS NRR/DEST/PSB 8D OGC 15-B-18 RES TELFORD,J RES/DRAA/SAIB RES/DRPS/RPSIB EXTERNAL: LPDR NSIC 10 10 1

1 1

1 1

1 1

1 1

1 1

1 1

1 ARM/DAF/LFMB NUDOCS-ABSTRACT g@z~QQ Ol RES7DE7SEB RES/DRPS DEPY NRC PDR 1

0 1

1 1

1 1

1 1

1 1

1 8'

~< g<5o W fC'7y R

I S

'A D

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 30 ENCL 28

l I

f L ~"

~

~

~

P.

OX 14000, JUNO BEACH, FL 33408.0420

+Nip

~/ttA>>

~Ul% 2 3 1988 L-88-274 10 CFR 50.90 10 CFR 50.12 U. S. Nuclear Regulatory Commission Attn:

Document Control Desk Washington, D.

C.

20555 Gentlemen:

Re:

St. Lucie Units 1 and 2

Docket Nos.

50-335 and 50-389 Proposed License Amendments Containment Inte rated Leak Rate Testin In accordance with 10 CFR 50.90, Florida Power 6

Light Company (FPL) submits herewith a request to amend Facility Operating Licenses DPR-67 and NPF-16 for St.

Lucie Units 1

and 2, respectively.

The St. Lucie Unit 1 and Unit 2 Technical Specifications each require that containment leakage rates be demonstrated at specified intervals and that they be determined to be in conformance with the criteria specified in Appendix J of 10 CFR 50 using the methods and provisions of ANSI N45.4-1972.

ANSI N45.4-1972 specifies the practices and test standard requirements for the quantitative determination of leakage rates for containment structures.

The standard provides for one of two acceptable methods for leakage-rate testing:

the Total Time method and the Point-to-Point method.

The proposed amendments reflect improved test methods including a newer method of evaluating test data, called the Mass Point method.

This Mass Point method is not recognized in ANSI N45.4-1972; therefore, the requirement to use methods delineated by this standard is proposed to be deleted from both Units'echnical Specifications.

EJWCILR. PLA pal t It,gp 4 pry' 8807010657 880623 PDR ADOCK 05000335 P

DCD an FPL Group company

~

~

U. S. Nuclear Regulatory Commission L-88-274 Page two Marked up copies of each Units'ffected Technical Specification pages are included as Attachment 1.

A Safety Evaluation in support of the proposed amendment is included as Attachment 2.

A "Determination of No Significant Hazards Consideration" is provided as Attachment 3.

Attachment' includes an exemption request from 10 CFR 50 Appendix J, in accordance with 10 CFR 50.12, to permit optional application of any NRC-approved method for containment integrated leak rate testing, including the Mass Point method.

FPL requests NRC review and approval of this proposed amendment and exemption by December 31, 1988 to support the early 1989 St. Lucie Unit 2 refueling outage.

The proposed amendment has been reviewed by the St.

Lucie Facility Review Group and the Florida Power 6 Light Company Nuclear Review Board.

In accordance with 10 CFR 50.91(b)(l),

a copy of the proposed amendment is being forwarded to the state designee for the State of Florida.

In accordance with 10 CFR 170.12(c),

FPL Check No.

7874 is attached as remittance for the license amendment application fee.

Please contact us if there are any questions about this submittal.

Very truly yours, W..

C y

Senior Vice President Nuclear WFC/EJW/gp Attachments (4)

CC'r. J. Nelson Grace, Regional Administrator, Region II, USNRC Senior Resident Inspector, USNRC, St. Lucie Plant Mr. Lyle Jerrett, Florida Department of Health and Rehabilitative Services EJWCILR.PLA

a STATE OF FLORIDA

)

) ss.

COUNTY OF PALM BEACH )

W. F.

Conwa being first duly sworn, deposes and says:

That he is Senior Vice President Nuclear, of Florida Power and Light Company, the Licensee herein; That he has executed the foregoing document; that the statements made in this document are true and correct to the best of his knowledge, information and belief, and that he is authorized to execute the document on behalf of said Licensee.

F.

way Subscribed and sworn to before me this

~aay of

, ~aE<

1-'f'

'~','NOVA'RY,'PUBLIC, in and for e County of Palm Beach, State of Florida 4

/'(

,14g,;,,Coainission r~r>>'i1ijj gotary Pubii<, State of Rorista gy Qrnrnission Expires June 1', 19M expires rain ~ Iawcsaca race

g/

f

/p