L-87-525, Application for Amends to Licenses DPR-67 & NPF-16,changing Tech Specs to Modify Requirements to Perform Moderator Temp Coefficient Test Near End of Each Cycle.Safety Evaluation Also Encl.Fee Paid

From kanterella
(Redirected from L-87-525)
Jump to navigation Jump to search
Application for Amends to Licenses DPR-67 & NPF-16,changing Tech Specs to Modify Requirements to Perform Moderator Temp Coefficient Test Near End of Each Cycle.Safety Evaluation Also Encl.Fee Paid
ML17221A566
Person / Time
Site: Saint Lucie  
Issue date: 12/22/1987
From: Woody C
FLORIDA POWER & LIGHT CO.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
Shared Package
ML17221A567 List:
References
L-87-525, NUDOCS 8712300085
Download: ML17221A566 (7)


Text

V ACCELERATED DISTRIBUTION DEMONSTRSCION SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:8712300085 DOC.DATE: 87/12/22 NOTARIZED: YES FACIL:50-335 St. Lucie Plant, Unit 1, Florida Power

& Light Co.

50-389 St. Lucie Plant, Unit 2, Florida Power

& Light Co.

AUTH.NAME AUTHOR AFFILIATION WOODY,C.O.

Florida Power

& Light Co.

RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

DOCKET ¹ 05000335 05000389

SUBJECT:

Application for amends to Licenses DPR-67

& NPF-16,modifying requirements to perform moderator temp coefficent test.

DISTRIBUTION CODE A001D COPIES RECEIVED:LTR ~ENCL~ SIZE:

TITLE: OR Submittal:

General Distribution NOTES RECIPIENT ID CODE/NAME PD2-2 LA TOURIGNY,E INTERNAL: ARM/DAF/LFMB NRR/DEST/CEB NRR/DEST/RS B NRR/XMAS/ILRB

= EG FI 01 1

EXTERNAL: LPDR NSIC COPIES LTTR ENCL 1

0 1

1 1

0 1

1 1

1 1

1 1

1 1

1 1

1-RECIPIENT ID CODE/NAME PD2-2 PD NRR/DEST/ADS NRR/DEST/MTB NRR/DOEA/TSB OGC/HDS2 RES/DE/EIB NRC PDR COPIES LTTR ENCL 5

5 1

1 1

1 1

1 1

0 1

1 1

1 j

A D

~,

H Ec'D m c.k~~g

$ (gg ~

R

8 A,"

D TOTAL NUMBER OF COPIES REQUIRED:

LTTR 20 ENCL 17

P. O.

14000, JUNO BEACH, FL 33408-0420

@4//y

~~re~<<

OEGEMBER 2 2 1987 L-87-525 U. S. Nuclear Regulatory Commission'ttn:

Document Control Desk Washington, D. C. 20555 Gentlemen:

Re: St. Lucie Units I and 2 Docket Nos. 50-335 and 50-389 Proposed License Amendments Moderator Tem erature Coef ficient Surveillance Re uirements In accordance with IO CFR 50.90, Florida Power & Light Company (FPL) submits herewith a request to amend Facility Operating Licenses DPR-67 and NPF-I 6.

The proposed amendment involves changes to the St. Lucie Units I

and 2

Technical Specifications which modify the requirements to perform a Moderator Temperature Coefficient (MTC) Test near the end of each cycle.

Under the proposed change this test would not be required if tests conducted at earlier times in the cycle, design MTC calculations, and core reactivity characteristics predict satisfactory MTC behavior will be obtained for the remainder of the cycle.

The proposed change will also modify St. Lucie Unit I MTC surveillance requirement 4.I.I.4.2.b so that it will be consistent with the Combustion Engineering Standard Technical Specifications and with the St. Lucie Unit 2 Technical Specifications.

Marked up copies of the affected Technical Specification pages for each Unit are included as Attachment I.

A Safety Evaluation in support of the proposed amendment is included as Attachment 2.

A "Determination of No Significant Hazards Consideration" is provided as Attachment 3.

The proposed amendment has been reviewed by the St. Lucie Facility Review Group and the Florida Power & Light Company Nuclear Review Board.

ln accordance with IO CFR 50.9l(b)(l), a copy of the proposed amendment is being forwarded to the state designee for the State of Florida.

sg ~eV~ +

EJW4/052/I, 87i2300085 87i222 PDR ADOCK'05000335 p

DCD an FPL Group company

t hl 1

0 e J d

U. S. Nuclear Regulatory Commission L-87-525 Page two In accordance with 10 CFR 170.2I, FPL Check No. 6779 is attached as remittance for the license amendment application fee.

Please contact us if you have any questions about this submittal.

Very truly yours, C. 0. Woo Executiv ice President COW/EJW/gp Attachments cc:

Dr. J. Nelson Grace, Regional Administrator, USNRC, Region II Senior Resident Inspector, USNRC, St. Lucie Plant Mr. Lyle Jerrett, Florida Dept. of Health and Rehabilitative Services EJW4/052/2

>> t4 4

tl

~ ~

ll 4

>> I jll Il I

4 r>>t lt I

"4 t-4l 1

4 4 I

~ r 4r I <>lA.

~

STATE OF FLOR1DA

)

)

ss.

COUNTY OF PALM BEACH )

~C.Q.WA i

>> d>>,

d That he is Executive Yice President of Florida Power 8 Light Company, the Licensee herein; That he has executed the foregoing document; that the statements made in this document are true and correct to the best of his knowledge, information, and

belief, and that he is authorized to execute the document on behalf of said Licensee.

C. O. Wood Subscribed and sworn to before me this

~~ayof ~~%~>> l9 87.

NOTARY PVNLZC STATE HY COHHTSSTOH BONDEO THRV GEH EXP OCFT SO r

N L THS. VND,

,NOTARY,PUBL1C, in and for the County

~of Pafm Beach, State of Florida C>>

v-e

~~

gI-, ~< g~~,.;

" My<Commission expires:

4 C

n II