L-86-506, Monthly Operating Repts for Nov 1986
ML20211P015 | |
Person / Time | |
---|---|
Site: | Saint Lucie, Turkey Point, 05000000 |
Issue date: | 11/30/1986 |
From: | Grant N, Woody C FLORIDA POWER & LIGHT CO. |
To: | NRC OFFICE OF RESOURCE MANAGEMENT (ORM) |
References | |
L-86-506, NUDOCS 8703020271 | |
Download: ML20211P015 (18) | |
Text
..
l AVERAGE DAILY UNIT POWER Livst DOCKET NO. 10
- UNIT Turkey Point 3 DATE Daepmher 19, 1986 COMPLETED BY N.W. Grant TELEPHONE (305) 694- 44~32 MONTH Mnvamhar- 14R6 DAY AVERACE DAILY POWER LEVEL (MWe Nes) 11/ 1/86 687 11/ 2/86 690 11/ 3/86 687 11/ 4/86 667 11/ 5/86 575 11/ 6/86 685 11/ 7/86 686 11/ 8/86 692 31/ 9/86 694 11/10/06 694 11/11/86 693 11/12/86 692 11/13/86 607 11/14/86 684 11/15/06 689 11/16/86 685 11/17/86 688 11/18/86 686 11/19/86 683 11/20/86 680 11/21/86 683 11/22/86 687 11/23/86 695 11/24/86 693 11/25/86 694 11/26/86 690 11/27/06 690 11/28/86 688 11/29/86 688 11/30/86 686 P888&isung PDH Q\ o\
j
OPERATING DATA REPORT DOCKET NO 50 - 250 DATE 12/11/86
'. COMPLETED BY N. W. GRANT TELEPHONE- 305/694/4432 OPERATING STATUS .
- 1. UNIT NAME: TURKEY POINT UNIT 3
- 2. REPORTING PERIOD: NOVEMBER 1986
- 3. LICENSED THERMAL POWER (MWT): ______________ 2200
- 4. NAMEPLATE RATING (GROSS MWE): ______________. 760
- 5. DESIGN ELECTRICAL RATING (NET MWE): ________ 693
- 6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE): ___ 700
- 7. MAXIMUM DEPENDABLE CAPACITY (NET MWE): _____ 666
- 8. IF' CHANGES DCCUS IN CAPACITY RATINGS (ITEMS NUMBER 3 THROUGH 7)
SINCE LAST REPORT, GIVE REASONS: ________________________________________
- 9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE)________________________
- 10. REASONS FOR RESTRICTIONS, IF ANY: _______________________________________
MONTHLY -YTD- CUMULATIVE
- 11. HOURS IN REPORT PERIOD: _________________ 720 8016 122625.6
- 12. NUMBER OF HOURS REACTOR WAS CRITICAL _____ 720.0 6354.5 85432.2
- 13. REACTOR RESERVE SHUTDOWN HOURS __________ 0.0 0.0 844.4
- 14. HOURS GENERATOR ON-LINE _________________ 720.0 6187.0 84593.8
- 15. UNIT RESERVE SHUTDOWN HOURS _____________ 0 0 121.8
- 16. GROSS THERMAL ENERGY GENERATED (MWH) ____ 1577530 13250005 175455526
- 17. GROSS ELECTRICAL ENERGY GERERATED (MWH) _ 516300 4303591 56175136
- 18. NET ELECTRICAL ENERGY GENERATED (MWH) ___ 492379 4075738 53185319
- 19. UNIT SERVICE FACTOR ____;________________ 100.0 77.2 69.0
- 20. UNIT AVAILABILITY FACTOR ________________ 100.0 77.2 69.1
- 21. CAPACITY FACTOR (USING MDC NET) _________ 102.7 76.3 66.6
- 22. CAPACITY FACTOR (USING DER NET) _________ 98.7 73.4 62.6
- 23. UNIT FORCED OUTAGE RATE _________________ 0 18.1 7.9
- 24. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS :
REFUELING 3/5/97, 81 DAYS ______________________________________________
- 25. IF SHUT DOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP: ________
s DOCKET NO. 50-250 UNIT SHUTDOWNS AND POWER REDUCTIONS UNIT NAME Turkey Point Unit #3 DATE )ecember 12. 1986 COMPLETED BY 4. W. Grant REPORT MONTH November. 1986 TELEPHONE (305) 694-4432
- , 5? "h
)g5Ei Licensee E
% L Cause & Corrective h Date i 3g i 2 Event u '2 k"l Action to
$5 $ j di g Report a rE C !' Prevent Recurrence S
Unit #3 had no shutdowns or significant power reductions.
I I 2 3 4 F Foiced Reason : Method: Exhibit G -Instructions 5 Scheduled A Lquipment Failure (Explain) 1-Manual for Preparation of Data B-Maintenance or Test 2-Manual Scrarn. Entry Sheets for Licensee C-Refueling 3-Automatic Scram. Event Report (LER) File (NUREG-4 D Regulator) Restriction 9 Other (Explain) 0161) 1.-Operator Training & License Eumination F- Administ rative p ,
5 G-Operaticnal I i ror ( F splam ) 4- . /. 4a 4 4 eve.,..es Exhibit I Same Source t'8/77) Il-Ot her ( E xplaini l
1
SUMMARY
OF OPERATING EXPERIENCE DOCKET NO.- sn_pso UNIT Turkey Point Unit }__
DATE December 12. 1986 COMPLETED BY N. W. Grant TELEPHONE (305) 694-4432 REP RT HONTH November. 1986 Unit #3 operated at essentially full power and had no " unit shutdowns or significant power reductions."
l
Am
.: AVER AGE DAILY UNITPOWER LivrL DOCKET NO. 50-251 g,7 Turkey Point 4 DATE Decomhor 17, 1986 COMPLETED BY
, . ant TELEPHONE MONTH November. 1986 DAY AVERAGE DAILY POWER LEVEL (MWe Net) 11/ 1/86 218 11/ 2/86 592 11/ 3/86 686 11/ 4/86 688 11/ 5/86 689 11/ 6/86 687 11/ 7/86 688 11/ 8/86 691 11/ 9/86 692 11/10/86 281 11/11/86 416 11,'12/86 617 l 11/13/86 680 l 11/14/86 368 11/15/86 686 11/16/86 685 11/17/86 695 11/18/86 498 11/19/86 563 11/20/86 679 11/21/86 678 l
11/22/86 603 I 11/23/86 692 11/24/86 689 11/25/86 690 11/26/86 692 11/27/86 695 11/28/86 694 11/29/06 692 11/30/86 688
,t OPERATING DATA REPORT DOCKET NO 50 - 251
. DATE 12/11/86 COMFLETED BY N. W. GRANT TELEPHONE. 305/694/4432 OPERATING STATUS -
- 1. UNIT'NAME: TURKEY POINT UNIT 4
- 2. REPORTING PERIOD NOVEMBER 1986
- 3. LICENSED THERMAL POWER (MWT): ______________ 2200
- 4. NAMEPLATE RATING (GROSS MWE): ______________ 760
- 5. DESIGN ELECTRICAL RATING (NET MWE): ________ 493
- 6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE): ___ 700
- 7. MAXIMUM DEPENDABLE CAPACITY (NET MWE): _____ 666
- 8. IF CHANGES OCCUS IN CAPACITY RATINGS (ITEMS NUMBER 3 THROUGH 7)
SINCE LAST REPORT, GIVE REASONS: ________________________________________
- 9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE)________________________
- 10. REASONS FOR RESTRICTIONS, IF ANY: _______________________________________
MONTHLY -YTD- CUMULATIVE
- 11. HOURS IN REPORT PERIOD: _________________ 720 8016 116357.0
- 12. NUMBER OF HOURS REACTOR WAS CRITICAL _____ 706.4 2304.2 79939.3
- 13. REACTOR RESERVE SHUTDOWN HOURS __________ 0.0 0.0 166 6
- 14. HOURS GENERATOR ON-LINE _________________ 702 1 2087.9 77183.0
- 15. UNIT RESERVE SHUTDOWN HOURS _____________ 0 0 32.1
- 16. GROSS THERMAL ENERGY GENERATED (MWH) ____ 1459367 4184009 163221738
- 17. GROSS ELECTRICAL ENERGY GERERATED (MWH) _ 471225 1334266 51976838
- 18. NET ELECTRICAL ENERGY GENERATED (MWH) ___ 448349 1236869 49198077
- 19. UNIT SERVICE FACTOR _____,_______________ 97.5 26.0 66.3
- 20. UNIT AVAILABILITY FACTOR ________________ 97.5 26.0 66.4
- 21. CAPACITY FACTOR (USING MDC NET) _________ 93.5 23.2 64.9
- 22. CAPACITY FACTOR (USING DER NET) _________ 89.9 22.3 61.0
- 23. UNIT FORCED OUTAGE RATE _________________ 2.5 13.4 6.7
- 24. SHUTD,0WNS SCHEDULED OVER NEXT 6 MONTHS :
- 25. IF SHUT DOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP: ________
i t
I
)
4
. . . . . ,.,,-__.,--,--,,.,~.,_.4., ,..__,,,- , ~ ,_., m .,,_,m.m .v.- m.,_ ,.,.m. ,v _ _ ,.__ m.- - , m e w.-._..my,_.m,ww,w_mm__,.
PAGE 1 of 2 .,
DOCKET NO. 50-251 -
UNIT SHUTD0wNS AND POWER REDUCTIONS UMT NABIE Turkov Po- nt Uni t 4.
i DATE 3ecember .2. 1986 REPORT MONDg N n vomh p r . 1986 (30 5 -
432 i
e % =3 g
\
E:
e.
E gsx Licensee ge, ca.,, a co,,,c,g,,
km,
{
No. Dale ij g it ,gg& Event sg Action lo
" $3 E jiEj R*P"'8 EU f'g Prevent Recurrence 6
i 4 HC HTEXCH The return to full power i 10 861023 F 0.0 H operation from the outage l to inspect for condenser
! 1eaks was delayed for l secondary chemistry control
- and condenser leak checking.
1 17.9 3 251-86-25 HH VALVEX The reactor tripped foT10 wing 11 861110 F A i
' the failure of a solenoid i coil in a feedwater flow control valve which resulted l in low steam generator level.
l The coil was replaced,and full
! power operation was resumed
! after. a hold for secondary 2
ch'emistry control, I
! I 2 3 4 F Forced Reason: Method: Exhibit G . Inseructions i S Scheduled A Equipenent Failure (Explain) l-Manuel for Preparation of Data B-Maintenance of Test 2-Manuel Scrasn. Entry Sheets for Licensee 1
I C Refueling 3-Autosnatic Scrain. Event Report iLER) File INUREG-D-Regulator) Reser.ction $4ther(Explaen) 01611
! I -Operator Tsaining A Ucens I samination ,
1 F Adnunistrative 5
- G Operatiinul I reur IF splain I c . /.e a sadowca..,# Exhibit I Same Source l'8/77) II-Other i Laplain) j
i 4
PAGE 2 of 2 UNIT 5HUTDOWNS AND FOWER REDUCDONS DOCKET NO. 50-251 UNIT NAME Turkey Po- nt Unit 4 DATE December .2, 1986 I
COMPLETED ay fl . W. Grant f REPORT MONTH N o ve mb e r , 1986 1ELEPHONE (305) 694-4432
- l "i
E' E_ E 3 Licensee E, Cause & Corrective No . Date h 3g ( )YkyE Event E? kw. Action to
- $. E jiji g d
Repor
- mO f'l Prevent Recurrence 12 861118 F 0.0 A 5 HH VALVEX Power was reduced to approximately 10% to repair the 4A feedwater regulator valve which had'a problem wi th the positioner.
Following repairs and a secondary chemistry hold, the unit returned to full power operation.
l l 3 4 f Forced Reason: Method: Exhibit G Instructions S Scheduled A Equiprnent Failure (Explain) 1-Manual for Preparation of Data B Maintenance of Test 2 Manual Scram. Entry Sheets for Licensee C-Refueling 3 Automatic Scram. Event ReporI (LER) File (NUREG-D-Regulatory Rest iction @Osher(Explain) 0161) 1.-Operator Training & Ucense Examination ,
F-Adnunist rative 5 G Operatomal I r ror iF splain > g _ f.e ao 44em..,# Exhibit I Same Source l'8/77) ll Other (Explain) i -
~
SUMMARY
OF OPERATING EXPERIENCE DOCKET NO. 50-251 UNIT Turkey Point Unit 4 DATE _ Decembe r 12. 1986 COMPLETED BY N v. Grant TELEPHONE f100 694-4432 REP RT HONTH November, 1986 See the " unit shutdown and power reductions" report.
,-,,,-,,..,,,-.,,~w.,,-- _ -.- ,,- -,--.-- ,-a, , - . - - . . , --.,. - _ . _ , _ _ . . - , . . . , - . - . , . - - , , , , . ,.- ., ,,,, - - , , . - _ , . . ~ .
5 AVER AGE DAILY ONIT PCtf R LivgL DOCKET No. 50 m i
UNIT St. Lucie Unit 1 DATE December 12, 1986 i
COMPLETED BY N.W. Grant TELErilONE (305)694-4432 h00 NTH November, 1986 DAY AVERACE DAILY POWER LEVEL IMWefdeo 11/ 1/86 843 11/ 2/86 843 11/ 3/86 845 11/ 4/86 843 11/ 5/86 844 11/ 6/86 841 11/ 7/06 839 11/ 8/86 838 11/ 9/86 810 11/10/86 812 l
l 11/11/86 849 I 11/12/86 849 l 11/13/06 816 11/14/06 826 11/15/86 847 i 11/16/86 848 11/17/86 848 11/18/86 819 11/19/86 818 11/20/86 846 11/21/86 848 11/22/86 848 11/23/86, 848 11/24/96 848 11/25/86 847 11/26/86 843 11/27/86 847 11/28/86 844 11/29/86 842 11/30/86 842 i
~
~.- OPERATING DATA REPORT DOCKET NO 50 - 335 i DATE 12/11/86 COMPLETED BY N. W. GRANT TELEPHONE 305/694/4432 OPERATING STATUS l' 1. UNIT NAHE! ST. LUCIE UNIT 1
- 2. REPORTING PERIOD NOVEMBER 1986 3.' LICENSED THERMAL POWER (MWT): _ _ _ _ _ _ _ _ _ _ _ _ _ . . 2700 I 4. NAMEPLATE RATING (GROSS MWE): ______________ 850
- 5. DESIGN ELECTRICAL RATING (NET MWE): ________ 830
- 6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE): ___ 872
- 7. MAXIMUM DEPENDABLE CAPACITY (NET MWE): _____ 839
- 8. IF CHANGES OCCUS IN CAPACITY RATINGS (ITEMS NUMBER 3 THROUGH 7)
'SINCE LAST REPORT, GIVE REASONS: ________________________________________
[
- 9. POWER LEVEL TO WHICH RESTRICTED, I ANY (NET MWE)________________________
__________________________________F s'ie. REASONS FOR RESTRICTIONS, IF ANY: _______________________________________
I MONTHLY -YTD- CUMULAT'IVE
- 11. HOURS IN REPORT PERIOD
- _________________ 720 8016- 87168.0
- 12. NUMBER OF HOURS REACTOR WAS CRITICAL _____ 720.0 7672.7 63828.7 l
i 13. REACTOR RESERVE SHUTDOWN HOURS __________ 0.0 0.0 205 3
- 14. HOURS GENERATOR ON-LINE _________________ 720.0 7609.6 63411.7 i 15. UNIT RESERVE SHUTDOWN HOURS _____________ 0 0 39.3
- 16. GROSS THERMAL ENERGY GENERATED (MWH) ____ 1933003 20333077 161225344
- 17. GROSS ELECTRICAL ENERGY GERERATED (MWH) _ 636510 6746940 52823445
- 18. NET ELECTRICAL ENERGY GENERATED (MWH) ___ 604271 6423606 49857398
- 19. UNIT SERVICE FACTOR _____________________ 100.0 94.9 72.7
- 20. UNIT AVAILABILITY FACTOR ________________ 100.0 , 94.9 7'28
- 21. CAPACITY FACTOR (USING MDC NET) _________ 100.0 95.5 71.6 i 22. CAPACITY FACTOR (USING DER NET) _________ 101.1 96.5 70.1 i 23. UNIT FORCED OUTAGE RATE _________________ 0 1.2 4.0
- 24. SHUTDOWNS SCHEDULED OVER NEXT 4 MONTHS :
REFUELING 2/14/87, 63 DAYS _____________________________________________
! 25. IF SHUT DOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP: ________
j i
l
DOCKET NO. 50-335 UNIT SHUTDOWNS AND POWER REDUCTIONS UNITNAME St I in-ia Ifni t #1 DATE December 12, 1986 i COWLETED BY N. W. Grant REPORTMONTH November.1986 1ELEPHONE (305) 644-4437
- E c
, !? 3 j $5 Licensee $g **. Cause & Corrective No Date i 3g @ .3 s 5 Event g'2 E0 Action to
$~ $ jgg Report a mO g Prevent Recurrence 6
Unit #1 had no shutdowns or significant power reductions.
l i
j l
I
- j I 2 3 4 F Forced Reason
- Method: Exhibit G - Instructions i 5 Sched uled A Lyuipment Failure (Explam) 1-Manual for Preparation of Data B-Maintenance or Test 2-Manual Scram. Entry Sheets for Licensee 4
C. Refueling 3-Automatic Scram. Event Report (LER) File (NUREG-D-Regulatory Restriction %-Other (Explain 1 0161) 1: Operator Training & Ucense Examination t F- Ad numst rative p ,
5 G Operatomal I irnr ( F splain t c Ao4. 44 eve ..,# Exhibit I - Same Source I (9/77) II4hher iL splain)
') SUZH4ARY OF OPERATING EXPEILTENCE DOCKET NO. 50-335 UNIT St. Lucie Unit 1 DATE December 12. 1986 COMPLETED BY N. W. Grant TELEPHONE f305) 694-4432 REPORT HONTH November 1986 Unit #1 operated at essentially full power and had no " unit shutdowns or significant power reductions".
In accordance with requirements of Technical Specifications 6.9.1.6, there were no challenges to PORV or safety valves during the report month.
{
l l
l l
l L
AVERAGE DAILY UNIT POWf t tsvfL DOCKET NO. 50-:M9 UNIT St. I ncio finit 2 DATE December 12, 1986 COMPLETED BY N.W. Grant TELEPHONg (305)604-4432 MONTH November, 1986 DAY AVERAGE DAILY POWER LEVEL (MWe Net) 11/ 1/86 860 11/ 2/86 859 11/ 3/86 838 11/ 4/86 801 11/ 5/86 850 11/ 6/86 862 11/ 7/86 862 11/ 8/86 862 11/ 9/86 862 11/10/86 862 l 11/11/86 862 11/12/86 862 11/13/86 862 11/14/86 860 11/15/06 062 11/16/86 861 11/17/86 861 11/18/86 861 11/19/86 860 11/20/86 860 11/21/86 860 11/22/86 861
, 11/23/86' 860 11/24/86 860 11/25/86 859 11/26/86 860 l 11/27/86 860 11/28/86 860 l 11/29/86 858 11/30/06 837
't OPERATING DATA REPORT DOCKET NO 50 - 389 DATE 12/11/86 COMPLETED BY N. W. GRANT TELEPHONE 305/694/4432 OPERATING STATUS
- 1. UNIT NAME: ST. LUCIE UNIT 2
- 2. REPORTING PERIOD NOVEMBER 1986
- 3. LICENSED THERMAL POWER (MWT): ____-_________ 2700
- 4. NAMEPLATE RATING (GROSS MWE): --__-_______-- 850
- 5. DESIGN ELECTRICAL RATING (NET MWE): _______- 830
- 6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE): -__ 882
- 7. MAXIMUM DEPENDABLE CAPACITY (NET MWE): _____ 839
- 8. IF CHANGES OCCUS IN CAPACITY RATINGS (ITEMS NUMBER 3 THROUGH 7)
SINCE LAST REPORT, GIVE REASONS: ___-____-__-_____-_-___-__-_____________
- 9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE)__-_-________ _ _-___-____
- 10. REASONS FOR RESTRICTIONS, IF ANY: _____-__-______-____-__________________
MONTHLY -YTD- CUMULATIVE
- 11. HOURS IN REPORT PERIOD: ________-__-_____ 720 8016 29065.0
- 12. NUMBER OF HOURS REACTOR WAS CRITICAL _____ 720.0 6582.7 24631.6
- 13. REACTOR RESERVE SHUTDOWN HOURS _______-__ 0.0 0.0 0.0
- 14. HOURS GENERATOR ON-LINE _--___-__________ 720.0 6511.5 24083.8
- 15. UNIT RESERVE SHUTDOWN HOURS __--_-_-_____ 0 0 0
- 16. GROSS THERMAL ENERGY GENERATED (MWH) ____ 1936676 17387313 62033846
- 17. GROSS ELECTRICAL ENERGY GERERATED (MWH) - 649530 5814200 20720880
, 18. NET ELECTRICAL ENERGY GENERATED (MWH) -__ 616873 5507096 19578139 l 19. UNIT SERVICE FACTOR ____--________-______ 100.0 81.2 82.9 l 20. UNIT AVAILABILITY FACTOR ---_________-___ 100.0 81.2 82.9
- 21. CAPACITY FACTOR (USING MDC NET) ___--____ 102.1 81.9 82.9
- 22. CAPACITY FACTOR (USING DER NET) _____--__ 103.2 82.8 82.4 l
l 23. UNIT FORCED OUTAGE RATE _________________ 0 1.1 8.4
- 24. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS :
- 25. IF SHUT DOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP: _-______
1
(
l l
l
-l UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO. 50-389 UNITNAME St. Lucie Unit #2 DATE December 12, 1986 COMPLETED BY N. W. Grant REPORT MONDI November. 1986 TELEPHONE (3050 644-4439 i
. "E -
= re a ,
. 1 : E y3 -c :4 Licensee g *, Cause & Corrective N" Date i 35 4 .255 Event ET 3 Action to
$3 E j di j Report = <N 0 jO Prevent Recurrence 6
Unit #2 had no shutdowns or significant Power reductions.
I I 2 3 4 f Forced Reason: Method: Exhibit G Instructions S Scheduled A-Lquipment Failure (Explain) 1 Manual for Preparation of Data B-Maintenance or Test 2-Manual Scram. Entry Sheets for Licensee C-Refueling 3-Automatic Scram. Event ReporI(LER) File (NUREG.
D-Regulatory Restriction @-Other (Explain) 0161) 1 -Operator Training & License Examination F- Ad nu nist ra t ive 5 G Oper4tional i ror if splam) s /.o ao 44 eve ..et Exlubit I Same Source 49/77) Il-Ot her i E splain )
SU21 MARY OF OPERATING EXPERIENCE DOCKET NO. g0_389 UNIT St. Lucie Unit 2 DATE Decomhpr 12. 1986 COMPLETED BY N. W. Grant TELEPHONE (305) 694-4432 l
REPORT MONTH November. 1986 Unit #2 operated at essentially full power and had no " unit shutdowns or significant power reductions".
In accordance with requirements of Techni. cal Specifications 6.9.1.6, there were no challenges to PORV or safety valves during the report month.
l l
l l
i
~ -
g-
_' P. O. BOX 14000. JUNO BEACH, FL 33408-0420 a .
~
j)Q DECEMBER 12 1986 L-86-506 Director, Office of Resource Management U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Re: Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 St. Lucie Units I an-12 Docket Nos. 50-335 and 50-389 Monthly Operatina Report
Dear Sir:
Attached are the November 1986 Operating Status Reports and Operating Summary Reports for Turkey Point Unit Nos. 3 and 4 and St. Lucie Unit Nos. I and 2.
Very truly yours, Ach,/
C.O.W y/
Group V President Nuclear nergy COW /NWG/gp Attachment cc: Dr. J. Nelson Grace, USNRC, Region ll Harold F. Reis, Esquire i
/t/
4 NWGI/005/l PEOPLE. . SERVING PEOPLE
-.._. .--_ -