L-84-112, Application for Amend to Licenses DPR-31 & DPR-41,changing Tech Specs to Add Definition of Heavy Loads & Prohibit Travel of Heavy Loads Over Irradiated Fuel Assemblies in Spent Fuel Pool

From kanterella
(Redirected from L-84-112)
Jump to navigation Jump to search
Application for Amend to Licenses DPR-31 & DPR-41,changing Tech Specs to Add Definition of Heavy Loads & Prohibit Travel of Heavy Loads Over Irradiated Fuel Assemblies in Spent Fuel Pool
ML17346A326
Person / Time
Site: Turkey Point  
Issue date: 04/27/1984
From: Williams J
FLORIDA POWER & LIGHT CO.
To: Eisenhut D
Office of Nuclear Reactor Regulation
Shared Package
ML17346A327 List:
References
REF-GTECI-A-36, REF-GTECI-SF, RTR-NUREG-0612, RTR-NUREG-612, TASK-A-36, TASK-OR L-84-112, NUDOCS 8405030028
Download: ML17346A326 (6)


Text

REGULATOR Y i FORMATION D IS TRI BUTION S Y I Et 1 (R IDS)

ACCESSION NOR:8405030028 DUCwDATE: 84/04/27 NOTARIZED; NO DOCKET FACIL:50"250 Turkey Point Planti Unit 3i Florida Power and Light C

05000250 50"251 Turkey Point Plant~

Unit 4i Florida Power and Light C

05000251 AUTH,NAHE AUTHOR AFFILIATION l'WILLIAMSi J ~ t'I.

F 1 or i da Power K Light Co, RECIP,NAME RECIPIENT AFFILIATION EISENHUT<D.G.

Division of Licensing

SUBJECT:

Application for amend t'o Licenses DPR-31 L DPR"41~changing ech Specs to add definition of heavy loads 8 prohibit travel of heavy loads over irradiated fuel assemblies in spent fuel pool; I

DISTRIBuTION CODE: A035S'OPIES RECEIVED:LTR ENCL SIZE:

TITLE-OR Submittal; USI A"36 Control of Heavy oad Near Spent Fuel NUREG-06 NOTES:

RECIPIENT ID CODE/NAME NRR ORB1 SC INTFRNAL: NRR NEIGHBORS09 NRR/DL/TAPtlG NRR/DSI/ASI RGN2 COPIES LTTR ENCL 7

7 1

1 1

1 1

1 RECIPIENT ID CODE/NAME NRR'SINGHgA 01 NRR/DL/GRAB 12 N

AEB EG F IL 04 LTTR ENCL 1

1 1

1 1

1 EXTERNAL: ACHS NRC PDR NTIS 13 02 6

1 1

1 1

LPDR NSIC 03 06 TOTAL NUMBER OF COPIES REQUIRED:

LTTR 28 ENCL 28

,V gf D

)l ll 3

lI A

l.

4

O.

FLORIDAPOWER & LIGHTCOMPANY April 27, 1984 L-84-112 Office of Nucl ear Reactor Regul ati on Attention:

Mr. Darrell G. Eisenhut, Director Division of Licensing U. S.

Nuclear Regulatory Commission Washington, D. C.

20555

Dear Mr. Ei senhut:

Re: Turkey Point Units 3 and 4

Docket Nos.

50-250 and 50-251 Proposed License Amendment Control of Heav Loads 2'

2 In accordance with 10 CFR 50.90, Florida Power 8I Light Company submits herewith three signed originals and forty copies of a request to amend Appendix A of Facility Operating Licenses, DPR-31 and DPR-41.

This amendment is submitted as recommended in the Draft Technical Evaluation Report on Control of Heavy Loads at Turkey Point Units 3 and 4, to prohibit the travel of heavy loads over irradiated fuel assemblies in the spent fuel pool.

An exception to this requirement i's also included to facilitate installation of a temporary crane for use during reracking modifications.

The proposed changes are described below and shown on the accompanying Techni cal Speci ficati on p ages.

~Pa e i The Table of Contents is revised to add the definition of heavy loads.

~Pa e 1-7 The definition 6f heavy loads is added.

~P3.10-2 A new restriction is added in the refueling section to prohibit the travel of.

heavy loads over irradiated fuel assemblies in the spent fuel pool.

An exception to this new specification is included for installation of a

temporary crane during reracking modifications.

PDR ADOCg

',8405030028 8

p 05000250 PDR PEOPLE... SERVING PEOPLE

0 Office of Nuclear Reactor Regulation Attention:

Hr. Darrell G. Eisenhut, Director Page 2

~P3.

2-A new restriction is added in the cask handling section to prohibit the travel of heavy loads over irradiated fuel assemblies in the spent fuel pool.

Pages B 3.10-1 and B 3.12-1 The Bases for the above specifications are revised.

In accordance with 10 CFR 50.91(a)(I), it has been determined that the proposed amendment does not involve any significant hazards considerations pursuant to 10 CFR 50.92.

The No Significant Hazards Considerations determination is attached.

I In accordance with 10 CFR 50.91(b)(I) a copy of the proposed anendment is being forwarded to the State Designee for the State of Florida.

The proposed amendment has been reviewed by the Turkey Point Pl ant Nuclear Safety Committee and the Florida Power 5 Light Company Nuclear Review Board.

Because this change is made at the request of the Commission as stated in the Draft Technical Evaluation Report, a license fee i s not provided with this request.

Very truly yours, J.

W. Willians, Jr.

Group Vice President Nuclear Energy JWW/PLP/js Attachment cc: J.

P. O'Reilly Regional Administrator, Region II U. S.

Nuclear Regulatory Commission 101 Mariett Street, N.W., Suite 2900 Atlanta, GA'0303 Lyle E. Jerrett, Administrator Radiological Health Services Dept. Health 5 Rehabilitative Services 1323 Winewood Boulevard Tel 1 ahassee, FL 32301 P NS-L1-84-150

ATTACHMENT Re:

Turkey Point Units 3 and 4

Docket Nos. 50-250 and 50-251 Proposed License Amendment Control of Heav Loads This amendment is made at the NRC request to prevent moving of heavy loads over irradiated fuel.

This item was included as a recommendation in the Draft Technical Evaluation Report on Control of Heavy Loads at Turkey Point Units 3

and 4.

Because this change constitutes an additional restriction not presently included in the technical specifications, it is similar to exmple ii of the Examples of Amendments That Are Considered Not Likely to Involve Significant Hazards Considerations as presented in the Federal Register Notice of Interim Final Rule dated April 6, 1983.

We have therefore determined that operation of Turkey Point Units 3 5 4 in accordance with the proposed amendment would not:

1) Involve a significant increase in the probability or consequences of an accident previously evaluated; or
2) Create the possibility of a new or different kind of accident from any accident previously evaluated; or
3) Involve a significant reduction in a margin of safety.

Our letter L-84-71 dated March 14, 1984 provided a request for license amendment to allow modifications to the Turkey Point Spent Fuel Storage Facilities.

Par agraph 3.4.2 of the Safety Analysis Report provided with that request discussed the potential accident of a temporary construction crane drop.

The results of this postulated accident were found to be acceptable in that report.

Because this temporary crane will be required to complete reracking modifications, it will be necessary for the temporary crane, which is a heavy load, to be lifted over irradiated fuel assembies in the spent fuel pool during installation of the crane.

For this reason, an exception to the requirement to prevent moving heavy loads over irradiated fuel has been included in this request.

This exception would allow moving of the temporary crane over the irradiated fuel during the scheduled Unit 3 rerack modifications and similar Unit 4 modifications being considered.

The significant hazards considerations associated with the use of the temporary crane were provided with the spent fuel storage modification anendment

request, referenced above.