L-81-306, Application for Amend to License DPR-67,revising Tech Specs to Incorporate TMI-2 Related Operational & Design Changes Re Shutdown Margin,Main Steam Isolation Sys Changes & Control Element Assembly Sleeving

From kanterella
(Redirected from L-81-306)
Jump to navigation Jump to search
Application for Amend to License DPR-67,revising Tech Specs to Incorporate TMI-2 Related Operational & Design Changes Re Shutdown Margin,Main Steam Isolation Sys Changes & Control Element Assembly Sleeving
ML17212A420
Person / Time
Site: Saint Lucie 
Issue date: 07/23/1981
From: Robert E. Uhrig
FLORIDA POWER & LIGHT CO.
To: Eisenhut D
Office of Nuclear Reactor Regulation
Shared Package
ML17212A422 List:
References
L-81-306, NUDOCS 8107280403
Download: ML17212A420 (8)


Text

REGULATORY FORMATION DISTRIBUTION SY (R IDS)

ACCESSION-NBR!8107280003-DOC ~ DATE'e 81/07/23 NOTARIZED: YES "FACIL>>:50 335 St's Lucie PlantP Unit 1E. Flor ida Power 8 Light'o.

AUTH" NAME'- 'UTHOR AFFILIATION UHRI Gg R, EI.

Florida Power L Light C'o.

RECIP ~ NAMKI REC'IPIENT-AFFIL'I ATION'ISENHUT'iDRG.

Division of Licensing DOCKK>>T>> 0 05000335

SUBJECT:

Application= for amend to License DPR 67 revising Tech" Specs" incorporate TMI-2 related operational L design changes re shutdown marginimain steam. isolation sys changes L, control>>

element assemoly sleeving.

DISTRISUTION CODE!:

ASSIS COPIES RECEIYED:LTR>>>>

ENCL. L>>

SIZE>>~+~'~'

TITLEI: Gener al Distr ibut1on forI af ter Issuance of Oper ating, I.icense NOTES:: P>>>>/L>>."4 8<+

4>>>>'+

RECIPIENT ID>> CODE/NAMKI ACT'ION::

ORBi P3 BC'Q INTERNAL: D/DIRgHUM FAC08 I L KI 06'EI.D11 RAD'SIYIT BR COPIES I.TTR ENCL>>

13 13 1

1 2

2 1

0 1

1 RKC IP IENT" ID CODE/NAME*

DIR'r DIV OF. LIC NRC PDR 02'S BR 10.

G FIL 01 COP IKS LTTR ENCL" li 1

1 1

0.

1 1

EXTERNAL'CRS NSIg 09 05 16 16 1

1 LPDR AT I S 03-1 1

1 1

JUL 3]. 881 TOTAL" NUMBER'F COPIES RKQULRKDR LTTR 01>>

ENCL'"

39'

e

~

~

'k n

R i

g I~

J W

F)

C I

JI t

z 41

>II A

1 dt

P.O. BOX 529100 MIAMI,FL 33152 1

FLORIDAPOWER 5 LIGHT COMPANY July 23, 1981 L-81-306 Office of Nuclear Reactor Regulation Attention:

Mr. Darrell G. Eisenhut.

Director Division of Licensing "U. S. Nuclear Regulatory Commission Washington, D.

C.

20555

Dear Mr. Ei senhut:

s eg((y JUL z ptge))

'Re:

St. Luci e Unit 1

Docket No. 50-335 Proposed License Amendment to Facility Operating License DPR-67 Shutdown Margin, Main Steam Isolation System

Changes, and Control Element Assembl Sleevin In accordance with 10 CFR 50.30, Florida Power 8 Light Company submits herewith three signed originals and forty copies of a request to amend Appendix A of Facility Operating License DPR-67.

This amendment is submitted as a result of incorporating TMI-2 related operational and design

changes, i.e. tripping all four Reactor Coolant Pumps on SIAS and automatically initiated auxiliary feedwater.

A change to the Design Feature section is included as a result of your request as well.

The changes in this request related to shutdown margin modify the amendment

, request we submitted for approval of uprating rated power from 2560 Mwt to 2700 Mwt.

(FPL letter L-80-381 dated November 14, 1980).

The proposed amendment is described below and shown on the accompanying Technical Specification pages bearing the date of this letter in the lower right hand corner.

Table 2.2-1 Pa e 2-4 8 Table 3.3-4 a

e 3/4 3-14 8

Pa e B2-5 The trip setpoint and allowable values for the steam generator pressure-low

, was increased.

Table 2.2-1 Pa e 2-5 3-4 8 Table 3.3-3 Pa e 3/4 3-12 8

Pa e 3/4 3-4

, The allowable 'value for trip bypass of the steam generator pressure-low trip was increased.

Pa es B 3/4 1-1 8

3 4 l-l 8 3/4 1-2 8 3/4 4-1 The requirements for shutdown margin were increased, and a shutdown margin calculational change is added.

8107280403 8l0723 PDR

  • DOCK 05000335 P

PDR Cke~

II P,d PEOPLE... SERVING PEOPLE

'y A

Hr. Darrell G. Eise Page 2

4

~Pe e 5-4 A statement regarding sleeving of control element assembly guide tubes is inserted in response to an NRC request.

We have determined that this is a Class III Amendment in accordance with 10 CFR 170.22.

A check in the amount of $4,000 is enclosed.

The proposed amendment has been revi ewed by the St. Lucie Facility Review Group and the Florida Power 5 Light Company Nuclear Review Board.

Very truly yours, Robert E. Uhrig Vice President Advanced Systems 8 Technology REU/JEtl/ras cc:

Nr. J.

P. O'Reilly, Region II Harold F.

Rei s, Esquire

~

~

I 4 hh, thigh hl h

h h h,

h i

v c

~ Ih

STATE OF FLORXDA

)

)

COUNTY OF DADE

)

ss Robert, E. Uhrig, being first duly sworn, deposes anQ says:

That he -is a Vice President of Florida Power 6 Light Company, the Licensee herein; That he has executed the foregoing document; that the state-ments made in this said document are true and correct to the best of his knowledge, information, and belief, and that he is authorized to execute the document on behalf of said Licensee.

Robert E. Uhrig Subscribed and sworn to before me this

- Z.3 day of l9 F/

~ NOTARY PUBLXC, i

"',,-,,State of Florida and for the county of Dade,

~ Ny commission expires:

M C

<Ofs+ Pubhc, Sfsfy Of Y Commission Expi~ p<obgg 3p,]gsp 8 sf argo Bondad CtlVP

o.

I

'T g

~

~

[W l

~i, /-.