L-2023-009, Owners Activity Report
| ML23031A038 | |
| Person / Time | |
|---|---|
| Site: | Saint Lucie |
| Issue date: | 01/31/2023 |
| From: | Strand D Florida Power & Light Co |
| To: | Office of Nuclear Reactor Regulation, Document Control Desk |
| References | |
| L-2023-009 | |
| Download: ML23031A038 (1) | |
Text
U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555-0001 RE:
St. Lucie Nuclear Plant, Unit 1 Docket No. 50-335 Owner's Activity Report January 31, 2023 L-2023-009 10 CFR 50.36 10 CFR 50.55a Enclosed is the Owner's Activity Report, Form OAR-1, for the St. Lucie Nuclear Plant, Unit 1, SL 1-31 refueling outage. The OAR-1 report is prepared, certified, and submitted upon completion of each refueling outage. The SL 1-31 refueling outage ended on October 4, 2022.
This letter contains no new regulatory commitments.
Should there be any questions regarding this submittal, please contact Kenneth Mack at (561) 904-3635.
Sincerely, V1 e-- sy Dianne Strand General Manager, Regulatory Affairs
Attachment:
Owner's Activity Report (OAR-1) for SL 1-31 Refueling Outage cc:
USNRC Regional Administrator, Region II USNRC Project Manager, St. Lucie Nuclear Plant USNRC Resident Inspector, St Lucie Nuclear Plant Florida Power & Light Company 6501 S. Ocean Drive, Jensen Beach, FL 34957 OWNER'S ACTIVITY REPORT (OAR-1)
FOR SL 1-31 REFUELING OUTAGE (3 pages follow)
Report Number: ISI-PSL-1-2023 Plant:
St. Lucie Nuclear Power Plant Unit 1 6501 South Ocean Drive Jensen Beach, Florida 34957 Commercial Service Date: December 21, 1976 Refueling Outage No.: SL 1-31 Current Inspection Interval: ISi-Fifth Interval, IWE-Third Interval Current Inspection Period: ISi - Third Outage First Period. IWE - First Outage Second Period Edition and Addenda of Section XI applicable to the inspection plan: ISi Fifth Interval and IWE Third Interval - 2007 Edition through 2008 Addenda Date and Revision of inspection plan: ISi - Fifth Interval January 4, 2023 Rev. 1 IWE - July 15, 2018, Rev. 0 Edition and Addenda of Section XI applicable to repairs and replacements, if different than the inspection plan: Same Code Cases Used: N-532-5, N-706-1, N-722-1, N-729-6, N770-2, N-892 CERTIFICATE OF CONFORMANCE I certify that (a) the statements made in this report are correct; (b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI; and (c) the repair/replacement activities and evaluations SUP. orting the completion of SL 1-31 conform to the requirements of Section XI.
Signed ~
Eric Christo her ISi Pro ram Owner Date 01/25/2023 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in this Owner's Activity Report, and state that, to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair/replacement activities and evaluation described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
--+-+---~~_!!'_"'-_':7'.._.--_J _!~* _Q
__ - ___ Commissions _____ 1_2_0_8_5_N~, 1~,R ___ _
National Board Number and Endorsements Date January 27, 2023
TABLE 1 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE Examination Category and Item Description Evaluation Description Item Number None None None
TABLE 2 ABSTRACT REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Code Item Date Repair/
Class Description Description of Work Completed Replacement Plan Number 2