L-2013-130, Refueling Outage SL2-20 Steam Generator Tube Inspection Report

From kanterella
(Redirected from L-2013-130)
Jump to navigation Jump to search

Refueling Outage SL2-20 Steam Generator Tube Inspection Report
ML13141A479
Person / Time
Site: Saint Lucie NextEra Energy icon.png
Issue date: 05/06/2013
From: Katzman E
Florida Power & Light Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-2013-130, SL2-20
Download: ML13141A479 (169)


Text

0FPL.

May 6, 2013 L-2013-130 10 CFR 50.55a 10 CFR 50.36 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Re:

St. Lucie Unit 2 Docket No. 50-389 Refueling Outage SL2-20 Steam Generator Tube Inspection Report Attached is the St. Lucie Unit 2 Technical Specification 6.9.1.12 steam generator tube inspection report for the winter 2012 refueling outage (SL2-20). This submittal was made within 180 days after the initial entry into hot shutdown following the completion of the steam generator inspection that was performed in accordance with TS 6.8.4.1, Steam Generator (SG)

Program.

Please contact Ken Frehafer at (772) 467-7748 should you have any questions regarding this submittal.

Sincerely, Eric S. Katzman Licensing Manager St. Lucie Plant ESK/KWF Attachment with 12 enclosures: St. Lucie Unit 2 Steam Generator Tube Inspection Report for SL2-20 St. Lucie Unit 2 Technical Specification Section 6.9.1.12 (Engineering Evaluation PSL-ENG-SESJ-12-006 - 168 Pages)

Florida Power & Light Company 6501 S. Ocean Drive, Jensen Beach, FL 34957

Engineering Evaluation PSL-ENG-SESJ-12-006 EC# 278014 Page 1 of 13 St. Lucie Unit 2 Steam Generator Tube Inspection Report for SL2-20 St. Lucie Unit 2 Technical Specification Section 6.9.1.12

Background

This report is provided in accordance with St. Lucie Unit 2 Technical Specification 6.9.1.12, "Steam Generator Tube Inspection Report" for the inspection conducted September 9-15, 2012 during refu~eling outage twenty (SL2-20). SL2-20 was the third refueling outage following installation of the Areva-NP Model 86/19TI replacement steam generators (SGs) in December, 2007. At the SL2-20 refueling outage, the replacement SGs had accumulated approximately 3.87 EFPY (46.40 EFPM) of cumulative operation since replacement in 2007. SL2-20 also marked the end of second operating cycle in the first sequential period of 144 EFPM. Following the SL2-20 refueling outage. St. Lucie Unit 2 entered HOT SHUTDOWN (Mode 4) on November 8, 2012 @ 17:16, which marked the beginning of the SL2-21 operating cycle. The Unit returned to service on November 23, 2012 @ 11:42. Therefore, the report is due to the NRC by May 07,2013.

The SL2-20 SG tube inspections were conducted in both 'A' and 'B' SGs as described below and meet Technical Specification (TS) Section 6.8.4.1.1.d.2 inspection requirements for the first half of the first sequential period.

a. The scope of inspections performed on each SG The scope of this examination is summarized in Table 1 below and is established to meet the following requirements:
1. Technical Specification 6.8.4.1 "Steam Generator (SG) Program."
2. Steam Generator Management Program: "Pressurized Water Reactor Steam Generator Examination Guidelines: Revision 7". EPRI, Palo Alto, CA: 2007. 1013706.

The basis for bobbin and +PointTM tube examinations is given in Table 1. Applicable industry qualified eddy current examination techniques are provided in Table 2.

Diagnostic rotating probe examinations (Special interest, SI) were completed as required based on the results of the bobbin coil.

Prior to starting the eddy current examination at the End-of-Cycle 19 (EOC-19) refueling outage in 2012, all of the previously installed hot-leg and cold-leg plugs in Steam Generator 2A and Steam Generator 2B were confirmed to be present in their correct locations.

In addition, all of the hot-leg and cold-leg plugs were confirmed to be free from degradation and visible signs of leakage based on the visual examination.

The plant TS requirement (TS Section 6.8.4.1.1.d.2) to inspect 50% of the tubes by the refueling outage nearest the midpoint of the 1st ISI period of 144 months had already been satisfied by the SL2-19 inspection performed in January, 2011. The SL2-20 inspection in September, 2012 was performed to monitor the extensive AVB wear indications.

Engineering Evaluation PSL-ENG-SESJ-12-006 EC# 278014 Page 2 of 13 St. Lucie Unit 2 Steam Generator Tube Inspection Report for SL2-20 St. Lucie Unit 2 Technical Specification Section 6.9.1.12 Secondary Side Inspections Secondary Side Inspections (SSI) during the SL2-20 refueling outage were completed in accordance with Chart 2 of ENG/CSI-NDE-00-07 Rev 11, "St. Lucie Unit 1 & 2 Steam Generator Secondary Side Integrity Plan" and included the following:

a Upper Bundle Flush a Sludge Lance FOSAR (Includes pre-bundle flush quick look, post-bundle flush quick look and final parts retrieval) 0 & M Warranty inspections including upper internals Feed water Ring Inspection cover condition assessment (the covers, bolts and locking hardware were inspected for any evidence of looseness of the cover or associated hardware. No abnormalities or loose hardware was observed).

There are currently no known foreign objects in the secondary side of the steam generators that require tracking.

Supplemental Eddy Current Testing AREVA (France) requested supplemental u-bend rotating probe +PointTM data to supplement the root cause evaluation for the increased number of AVB wear indications reported during the SL2-18 and SL2-19 inspections. Data was recorded for 62 tubes (872 u-bend AVB locations) in SG A, and 37 tubes (495 u-bend AVB locations) in SG B.

Supplemental Primary Side Inspections to address Westinghouse NSAL 12-01 Issue

Description:

Visual inspection of the steam generators (SGs) at a Westinghouse designed plant showed indications of degradation in the cladding and/or divider plate-to-channel head weld, with exposure and wastage of the channel head base. Westinghouse issued NSAL 12-01 "Steam Generator Channel Head Degradation" on January 5, 2012 and included recommended actions for the visual inspection at other plants.

Although the degradation is not credible for St. Lucie Unit 2, a visual inspection of the primary side channel head bowl was performed in accordance with the requirements presented in Westinghouse NSAL 12-01. No channel head degradation was detected. The documented results were provided to FPL.

Engineering Evaluation PSL-ENG-SESJ-12-006 EC# 278014 St. Lucie Unit 2 Steam Generator Tube Inspection Report for SL2-20 St. Lucie Unit 2 Technical Specification Section 6.9.1.12 TABLE I Basis for Tube Examination Samples Page 3 of 13 Technique Examination Sample Required or Basis (1)

Potential Supplemental J

Degradation 100% full lntRequired to satisfy TS Bobbin each SG length of all active tubes in Required SR 4.4.5.1 and TS Wear 6.8.4.1.

HL expansion transitions +/- 3.0" from the top of tubesheet:

ENG CSI-2.2, Rev. 38, Foreign Object The two outermost tubes exposed to Required Checklist item 1.D.

Wear the annulus.

Wear All tubes in Rows 1 through 4 along the tube free lane.

CL expansion transition +/- 3.0' from the top of tubesheet The two outermost tubes exposed to Required ENG CSI-2.2, Rev. 38, Foreign Object the annulus.

Checklist item 1.0.

Wear All tubes in Rows 1 through 4 along

+PointTM the tube free lane.

SG B Row 76 Column 103 requires CR 2007-20669 a full depth hot leg tubesheet rotating probe examination (TSH Supplemental (AR 00443081)

None

+3.0" to TEH)

Dings and Special Interest locations Supplemental Supplemental None observed during the inspection (discretionary)

A sample of tubes (u-bend locations)

Recommended by OEM in each SG to establish tube to AVB Supplemental AREVA Engineering to None gap conditions support AVB root cause evaluation Notes:

(1)

TS SR - Surveillance Requirement, TS - Plant Technical Specification

Engineering Evaluation PSL-ENG-SESJ-12-006 EC# 278014 Page 4 of 13 St. Lucie Unit 2 Steam Generator Tube Inspection Report for SL2-20 St. Lucie Unit 2 Technical Specification Section 6.9.1.12

b.

Active degradation mechanisms found (Note 1)

The SL2-20 examination results for St. Lucie Unit 2 identified mechanical wear degradation at the following locations:

Anti-vibration bar (AVB) tube contact points in the u-bends V-shaped support pad adjacent to an AVB Broached tube support contact points There was no evidence of corrosion degradation during any of the SL2-20 examinations.

Note 1: "Active Degradation" is a term used in the Steam Generator Technical Specifications and is synonymous with the term "Existing Degradation" used in EPRI Report 1019038 "Steam Generator Management Program: Steam Generator Integrity Assessment Guidelines" Revision 3, dated November 2009.

Engineering Evaluation PSL-ENG-SESJ-12-006 EC# 278014 Page 5 of 13 St. Lucie Unit 2 Steam Generator Tube Inspection Report for SL2-20 St. Lucie Unit 2 Technical Specification Section 6.9.1.12,

c.

Nondestructive examination techniques utilized for each degradation mechanism TABLE 2 Qualif ed Eddy Current Techniques Industry Damage Demonstrated Extended Depth Sizing Site-Specific Review Technique Qualification Mechanism Applicability Applicability Technique Deemed Acceptable Applied Detection Sizing Detection of Differential Mix 960041 V shaped Amplitude For 1 Bobbin Wa VsAnlis Yes Service Revision 13 Support pad Analysis Yes SviOe Wear (Using Vert-AVB Only Wear

_Max)

Absolute Mix 96004.3 Amplitude 2

Bobbin Revision 13 Wear AVB's None Analysis Yes Yes (Using Vert-Max)

Freespan N/A Egg crate 128413 Axial Sludge pile 3

Bobbin Broached None N/A Yes Revision 3 ODSCC supr support W / WO Dents

< 2.00 Vpp 270912 PLP Wear PLP Wear 4

Bobbin Revision 0 PLP Wear (part not (When Part N/A Yes N/A present)

Present)

Freespan 5

Bobbin 24013.1 Axial Dents/Dings >

None N/A Yes N/A Revision 2 ODSCC 2.00 Vpp and

< = 5.00 Vpp Differential Mix For

+Point 96910.1 Broached PLP Wear Amplitude Service 6

TM Revision 10 Wear supports (When Part Analysis Yes at Present)

(Using Vert-Broached Max)

TSP's

+Point 10908.4 Vhd TSP Mix For 7

TM Revision 1 Wear AVB Wear saped Amplitude Yes Service Support pad Vert-Max AVB Only For Single Service TM Revision

~Frequency Ys o

na

+Point 21998.1 Volum etric Freespan None Am ltu en eeded 8

TM Revision 4 FesaNoe Amplitude Ye neededs Analysis Peak basis to Peak 27901.1 27902.1 27903.1 PLP Wear

+Point 27904.1 Morphology PLP Wear For 9

t 27905.1 PLP Wear Dependent None Morphology Yes Service 27906.1 (part not Dependent 27907.1 present)

(All Rev. 1)

Note:

Table 2 is excerpted from AREVA Document No: 51-9101361-003, Techniques for St. Lucie (PSL) Unit 2, Summer 2012 Qualified Eddy Current Examination

Engineering Evaluation PSL-ENG-SESJ-12-006 EC# 278014 St. Lucie Unit 2 Steam Generator Tube Inspection Report for SL2-20 St. Lucie Unit 2 Technical Specification Section 6.9.1.12 Page 6 of 13

d.

Location orientation (if linear) and measured sizes (if available) of service induced indications INDICATION LISTINGS FOR SL2-20 (EOC-19*

Indication Description Enclosure #

SG 2A Bobbin WAR at AVB locations 20-100%TWD Enc 1 (21 pages)

SG 2A Bobbin WAR at AVB locations. 1-19%TWD Enc 2 (73 pages)

SG 2A Bobbin WAR at Broached Supports 20-100% TWD Enc 3 (1 page)

SG 2A Bobbin WAR at Broached Supports 1-19% TWD Enc 4 (1 page)

SG 2A Bobbin WAR at V-Shaped Pads Enc 5 (1 page)

SG 2A Bobbin WAR at AV4 Locations on Row 69 Enc 6 (1 page)

SG 2B Bobbin WAR at AVB locations 20-100%TWD Enc 7 (4 pages)

SG 2B Bobbin WAR atAVB locations 1-19%TWD Enc 8 (48 pages)

SG 2B Bobbin WAR at Broached Supports 20-100% TWD Enc 9 (1 page)

SG 2B Bobbin WAR at Broached Supports 1-19% TWD Enc 10 (2 pages)

SG 2B Bobbin WAR at V-Shaped Pads Enc 11 (1 page)

SG 2B Bobbin WAR at AV4 Locations on Row 69 Enc 12 (1 page) is referred to as EOC-1 9.

Note: In the Enclosures containing the indication listings, SL2-20

Engineering Evaluation PSL-ENG-SESJ-12-006 EC# 278014 St. Lucie Unit 2 Steam Generator Tube Inspection Report for SL2-20 St. Lucie Unit 2 Technical Specification Section 6.9.1.12 Page 7 of 13

e.

Number of tubes plugged during the inspection outage for each degradation mechanism St. Lucie Unit 2 Tube Plugging EOC 19 (SL2-20)

Degradation Mechanism SG A SG B Total Wear at Anti-vibration bar (AVB) tube 7(1) 0 7

contacts equal to 40%

Wear at Anti-vibration bar (AVB) tube 97(3) 15(3) 112 contacts (Preventive Plugging)

Wear at Broached Support locations 0

0 0

Loose Part Wear 0

0 0

Wear at AVB component V-shaped 0

1(2) 1 Support Pad (PTP) (2)

Total 104 16 120 Note 1) Seven tubes had bobbin probe wear indications that measured 40%TW and, therefore, required plugging based on Technical Specification plugging limits.

Note 2) One peripheral tube in SGB (R73 C156), had an indication at one of the V-shaped support pads and was preventatively plugged due to the lack of a qualified eddy current technique for depth sizing of these flaws.

Note 3) The preventative plugging candidates (tubes with AVB indications below the Tech Spec limit of 40%TW) were selected based on a combination of the depths, growth rates, and quantities of indications in these tubes. These tubes were selected to provide additional margin.

Engineering Evaluation PSL-ENG-SESJ-12-006 EC# 278014 St. Lucie Unit 2 Steam Generator Tube Inspection Report for SL2-20 St. Lucie Unit 2 Technical Specification Section 6.9.1.12

f.

Total number and percentage of tubes plugged to date Page 8 of 13 St. Lucie Unit 2 Steam Generator Cumulative Tube Plugging Summary SL2-20 SG

  1. Plugged

% Plugged 2A 128 1.42%

2B 27 0.30%

g.

The results of condition monitoring, including the results of the tube testing pulls and in-situ All tubes satisfied the structural integrity and accident-induced leakage performance criteria based on the condition monitoring (CM) evaluation performed at EOC-19. No tubes required in-situ pressure testing for either tube burst or leakage. Therefore, all tubes met the structural and leakage integrity requirements of the St. Lucie Unit 2 Technical Specifications. The number and severity of the detected degradation for all mechanisms were conservatively predicted by the EOC-18 operational assessment (OA). Severity was measured in terms of the observed maximum depth of worst indication at EOC-19 and how well it was predicted by the prior cycle OA. This was done for all degradations mechanisms, and for all cases, the OA projections bounded the observed results.

Therefore, the OA methods and assumptions were confirmed and corrective actions were not necessary.

No tube pulls were warranted or implemented.

h.

The effective plugging percentage for all plugging in each SG No tube repair methods (i.e. sleeving) are approved for St. Lucie Unit 2 that would have an effect on the effective plugging percentages. Therefore, the applicable effective plugging percentage is synonymous with the % Plugged in item f. above.

Engineering Evaluation PSL-ENG-SESJ-12-006 EC# 278014 Page 9 of 13 St. Lucie Unit 2 Steam Generator Tube Inspection Report for SL2-20 St. Lucie Unit 2 Technical Specification Section 6.9.1.12 ADDITIONAL INFORMATION The following information is included to assist the staff in their review of the information provided in this report.

Abbreviations SG - Steam Generator ISI - In-service Inspection ECT - Eddy Current Testing NEI - Nuclear Energy Institute EPRI - Electric Power Research Institute Acronyms H/L -

Hot Leg C/L -

Cold Leg LAR -

Lead Analyst Review - Used in the Tubes Plugged Listings DWS -

Deep Wear Scar Standard - Used in the Tubes Plugged Listings MVOK -

Machine Vision OK (location position acceptable) - Used in the Tubes Plugged Listings PLP -

Possible Loose Part WAR -

Mechanical Wear TWD -

Through Wall Depth TSH -

Tubesheet Hot Leg TEH -

Tube End Hot Leg TSC -

Tubesheet Cold Leg TEC -

Tube End Cold PTP -

Preventative Tube Plug PID -

Positive Identification - Used in the Tubes Plugged Listings TBP -

To Be Plugged - Used in the Tubes Plugged Listings EOC-1 9 End-of-Cycle 19 (Synonymous with SL2-20)

SL2-20 St. Lucie Unit 2 Operating Cycle 20 FIGURES Figure 1 provides a side view of the installed St. Lucie Unit 2 RSGs.

Figure 2 provides a detailed view of the anti-vibration bar arrangement and broached tube support locations.

Figure 3 provides a schematic of the anti-vibration bar (AVB) stiffener configuration. The schematic includes v-shaped support pads. The v-shaped support pads are adjacent to the terminal ends of some AVBs.

Figure 4 identifies the deepest row that each AVB penetrates into the tube bundle to provide lateral support for the u-bends. A small number of wear indications were reported in tubes in Row 69 where the apex of the u-bend runs adjacent to the AVB4 u-bend transition. These indication listings are provided in Enclosure 6 to for SG A, and in Enclosure.12 to Attachment 1 for SG B.

Engineering Evaluation PSL-ENG-SESJ-12-006 EC# 278014 Page 10 of 13 St. Lucie Unit 2 Steam Generator Tube Inspection Report for SL2-20 St. Lucie Unit 2 Technical Specification Section 6.9.1.12 Figure 1 PSL-2 Steam Generator Schematic

Engineering Evaluation PSL-ENG-SESJ-12-006 EC# 278014 St. Lucie Unit 2 Steam Generator Tube Inspection Report for SL2-20 St. Lucie Unit 2 Technical Specification Section 6.9.1.12 Page II of 13 Figure 2 IPSL-2 RSG Tube Support and AvI L.ivuut

Engineering Evaluation PSL-ENG-SESJ-12-006 EC# 278014 St. Lucie Unit 2 Steam Generator Tube Inspection Report for SL2-20 St. Lucie Unit 2 Technical Specification Section 6.9.1.12 Figure 3 Anti Vibration Bar (AVB) Stiffener Configuration with V-Shaped Support Pad Page 12 of 13 A'KTI-vMeRA11bN BM

-. CLAMP ASEMULY ASS2IIBLAE GRiDE.

Engineering Evaluation PSL-ENG-SESJ-12-006 EC# 278014 St. Lucie Unit 2 Steam Generator Tube Inspection Report for SL2-20 St. Lucie Unit 2 Technical Specification Section 6.9.1.12 Page 13 of 13 Figure 4 U-Bend Tubes and AVB Showing General Transition Row Relationship

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:37:52 Component: S/G A Page 1 of 21 Bobbin AVB Wear Indications 20% to 100%

(Degraded Tubes)

QUERY: QueryMl ROW COL VOLTS DEG CHN IND %TW LOCATION, Enc. 1 Page 1 of 21 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 EXT EXT UTIL 1

UTIL 2

CAL # LEG PROBE 47 47 48 51 53 54 56 59 62 66 66 66 67 68 68 68 68 69 69 69 72 72 73 73 73 73 73 73 73 74 74 74 74 154 162 161 162 162 9

161 160 11 13 99 113 104 75 ill 115 155 102 106 108 103 105 18 74 76 98 100 102 116 73 89 103 109 0.58 0.60 0.62 1.17 0.61 0.75 1.06 0.78 0.68 1.01 0.87 0.63 0.69 0.91 1.39 0.79 0.66 0.89 0.84 0.86 0.59 1.04 0.73 0.72 0.78 0.80 0.74 0.88 0.70 0.91 1.36 1.11 0.74 0.63 0.74 0.67 0.72 0.78 0.61 0.91 1.01 0.84 0.65 0.67 0.62 1.04 0.89 0.96 0.97 0.89 0.80 0.75 0.85 1.15 0.70 0.91 0.87 0.73 0.74 1.11 0.67 0.92 0.87 1.16 0.71 0.76 0.88 0.74 0.87 0.73 0.70 0.62 0.77 0.54 0.92 1.00 0.65 0.67 1.34 111 P2 111 P2 115 P2 109 P2 112 P2 119 P2 107 P2 109 P2 113 P2 118 P2 11 P2 112 P2 125 P2 119 P2 110 P2 114 P2 113 P2 117 P2 122 P2 85 P5 77 P5 111 P2 100 P2 92 P5 109 P2 104 P2 115 P2 118 P2 120 P2 116 P2 114 P2 118 P2 122 P2 117 P2 119 P2 114 P2 123 P2 112 P2 113 P2 106 P2 116 P2 119 P2 108 P2 112 P2 113 P2 110 P2 112 P2 125 P2 121 P2 121 P2 118 P2 113 P2 114 P2 118 P2 125 P2 118 P2 113 P2 122 P2 120 P2 117 P2 124 P2 119 P2 107 P2 107 P2 114 P2 122 P2 120 P2 110 P2 110 P2 109 P2 110 P2 112 P2 113 P2 107 P2 109 P2 114 P2 113 P2 115 P2 118 P2 TWD 20 TWD 20 TWD 21 TWD 29 TWD 20 TWD 22 TWD 25 TWD 21 TWD 21 TWD 26 TWD 26 TWD 21 TWD 20 TWD 23 TWD 30 TWD 24 TWD 22 TWD 23 TWD 22 TWD 21 TWD 20 TWD 26 TWD 22 TWD 22 TWD 21 TWD 21 TWD 21 TWD 23 TWD 20 TWD 24 TWD 29 TWD 26 TWD 21 TWD 21 TWD 20 TWD 22 TWD 21 TWD 23 TWD 20 TWD 25 TWD 25 TWD 22 TWD 21 TWD 22 TWD 20 TWD 28 TWD 26 TWD 24 TWD 24 TWD 23 TWD 22 TWD 22 TWD 23 TWD 26 TWD 20 TWD 23 TWD 22 TWD 20 TWD 20 TWD 26 TWD 20 TWD 24 TWD 22 TWD 26 TWD 23 TWD 21 TWD 23 TWD 23 TWD 25 TWD 23 TWD 22 TWD 20 TWD 24

,TWD 20 TWD 26 TWD 27 TWD 22 TWD 22 TWD 29 AV3 AV6 AV6 AV6 AV6 AV3 AV6 AV6 AV7 AV6 AV6 AV3 AV3 AV6 AV6 AV7 AV6 AV7 AV3 AV4 AV4 AV6 AV3 AV4 AV5 AV3 AV4 AV4 AV3 AV5 AV4 AV5 AV4 AV5 AV3 AV6 AV3 AV7 AV6 AV5 AV5 AV5 AV3 AV4 AV6 AV5 AV4 AV6 AV5 AV6 AV5 AV5 AV4 AV5 AV6 AV4 AV5 AV6 AV5 AV5 AV4 AV5 AV6 AV4 AV5 AV7 AV5 AV6 AV5 AV4 AV3 AV3 AV5 AV6 AV6 AV5 AV5 AV4 AV3

-0.24

+0.18

+0.18

+0.18

+0.18

-0.15

-0.33

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.11

+0.00

+0.00

+0.00

-0.22

+0.00

+1.19

+1.40

+0.11

+0.00

+0.99

+0.00

+0.00

+0.26

-0.04

+0.11

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

-0.02

+0.00

+0.00

+0.00

+0.00

-0.18

-0.18

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.11

+0.07

+0.00

+0.00

+0.15

+0.04

+0.09

+0.00

+0.09

+0.13

+0.02

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

-0.31

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00 TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEC TEH TEC TEH TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH LAR LAR LAR 11 1

1 1

52 2

52 52 19 27 31 13 29 27 27 2

2 20 30 29 29 29 30 30 54 13 13 20 20 20 20 27 14 17 31 29 29 29 14 14 17 17 17 19 19 31 13 13 20 29 54 13 13 13 13 13 13 20 20 20 30 30 27 14 14 17 17 17 17 17 19 19 19 19 19 19 31 HOT HOT HOT HOT HOT COLD HOT HOT COLD COLD HOT HOT HOT COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD HOT HOT HOT HOT HOT COLD HOT HOT HOT HOT HOT COLD COLD HOT HOT HOT HOT HOT HOT COLD COLD HOT HOT COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610DL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 75 72 75 76 75 86 75 94 75 96 75 102 75 104 76 75 76 97 76 109 77 18 77 72 77 74 77 77 77 77 77 77 78 78 78 78 78 78 78 78 76 98 102 104 106 116 75 77 89 95 97 99 101 103

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:37:52 Component: S/G A Page 2 of 21 Bobbin AVB Wear Indications 20% to 100%

Bobbin AVB Wear Indications 20% to 100%

(Degraded Tubes)

QUERY: QueryMl, Enc. 1 Page 2 of 21 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.69 1.00 78 105 0.73 1.03 1.23 1.69 78 109 1.26 0.63 79 74 1.03 79 76 0.88 79 86 0.88 79 92 0.84 0.61 0.62 79 98 1.20 1.24 79 100 1.00 1.67 0.84 79 102 0.64 0.80 0.56 79 106 0.82 80 71 1.07 0.81 80 89 0.74 0.71 80 93 0.90 0.98 80 97 0.95 1.17 80 103 0.72 0.76 0.77 2.04 1.16 80 109 0.69 1.32 0.81 80 111 0.62 81 72 0.77 81 76 1.07 0.88 81 78 0.87 81 82 0.84 81 96 0.97 81 98 0.81 0.98 1.58 81 102 0.83 1.09 81 104 1.44 1.05 82 71 0.88 0.78 1.18 0.80 82 73 1.21 82 75 1.37 1.79 1.95 0.90 82 77 0.84 0.92 82 79 0.77 82 85 0.96 1.08 82 87 0.60 82 89 0.89 0.73 82 91 0.58 82 93 0.79 0.98 0.63 82 95 0.64 0.81 82 97 0.57 0.65 82 99 1.01 0.98 DEG 124 120 117 117 116 115 ill 109 116 117 ill 118 114 110 112 112 114 105 110 il 112 112 116 117 118 118 117 118 113 113 120 108 103 104 104 104 100 ill 108 106 120 112 115 117 121 119 122 120 114 122 119 ill 110 113 114 ill 121 112 108 107 106 116 116 114 116 112 113 109 107 109 ill 106 ill 112 107 112 110 110 110 114 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW LOCATION 20 AV4

+0.00 25 AV5

+0.00 21 AV2

+0.00 25 AV3

+0.00 27 AV4

+0.00 31 AV5

+0.00 29 AV5

+0.29 20 AV3

+0.00 25 AV6

+0.00 23 AV7

+0.00 25 AV3

+0.00 24 AV3

-0.04 20 AV4

-0.07 21 AV6

-0.04 30 AV5

+0.00 30 AV4

+0.00 27 AV4

+0.00 34 AV3

+0.00 25 AV2

+0.00 22 AV5

+0.00 25 AV4

+0.00 20 AV3

+0.00 22 AV4

+0.00 25 AV4

+0.00 22 AV5

+0.11 20 AV5

+0.00 20 AV4

+0.00 23 AV5

+0.00 24 AV4

+0.00 24 AV6

+0.00 27 AV5

+0.00 20 AV6

+0.00 20 AV5

+0.00 21 AV4

+0.00 33 AV3

+0.00 26 AV2

+0.00 21 AV6

+0.00 30 AV5

+0.29 23 AV4

+0.00 20 AV4

+0.00 21 AV6

+0.04 25 AV4

+0.07 23 AV5

+0.09 22 AV4

+0.04 20 AV4

+0.00 24 AV6

+0.00 22 AV5

+0.00 24 AV3

+0.00 30 AV4

+0.02 22 AV6

+0.00 26 AV4

+0.00 29 AV6

-0.02 24 AV5

+0.00 23 AV2

+0.31 21 AV3

+0.00 27 AV4

-0.26 21 AV5

+0.00 27 AV6

+0.00 29 AV2

+0.00 32 AV3

+0.00 33 AV4

+0.00 23 AV5

-0.15 22 AV6

+0.00 23 AV7

+0.00 21 AV3

+0.00 24 AV5

-0.22 26 AV6

+0.37 20 AV4

+0.00 25 AV4

+0.00 23 AV3

+0.00 20 AV4

-0.07 24 AV7

+0.00 26 AV6

+0.00 21 AV4

+0.00 21 AV5

+0.00 24 AV4

+0.00 20 AV5

+0.00 22 AV6

+0.00 27 AV6

+0.00 27 AV5

+0.00 EXT TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC EXT TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH UTIL 1

UTIL 2

CAL #

31 31 31 31 31 31 29 29 14 14 17 17 17 17 19 19 19 19 19 19 19 19 31 13 13 18 18 18 18 20 20 30 30 30 30 30 29 29 29 29 13 13 13 13 11 18 20 20 20 20 20 30 30 14 14 14 14 14 14 14 14 14 14 14 14 12 12 17 17 17 17 17 17 17 17 17 19 19 19 19 LEG HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610TUL 610UL 610UL 61EUL 610UL 610UL 610UL 610UL 61OUL 610TUL 61OUL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 61OUL 610UL 610UL 61OUL 610UL 61OUL 61OUL 61OUL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:37:52 Component: S/G A Page 3 of 21 Component: S/C A Page 3 of 21 Bobbin AVB Wear Indications 20% to 100%

(Degraded Tubes)

QUERY: QueryMl, Enc. 1 Page 3 of 21 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 82 101 0.56 0.80 0.76 82 103 0.83 1.09 0.80 1.80 1.04 82 105 1.41 1.04 0.74 83 72 0.97 83 76 0.85 1.13 1.65 0.72 83 78 1.19 0.69 83 86 0.73 83 88 0.62 0.60

0. 95 0.67 83 90 0.59 1.38 0.63 1.41 83 92 1.05 0.65 0.83 0.58 83 94 0.96 1.08 0.98 83 96 0.59 0.68 1.13 83 98 1.28 1.40 83 100 0.98 0.58 83 102 0.90 0.74 0.81 83 104 0.82 0.84 83 108 0.72 84 71 0.71 0.85 84 75 1.12 84 77 1.17 1.78 1.81 84 81 1.16 84 85 0.86 0.85 0.82 84 87 0.94 0.90 84 89 0.77 1.00 1.01 84 91 0.78 84 93 0.93 1.50 1.14 1.48 84 95 0.93 84 97 1.07 84 99 1.28 1.02 1.44 1.50 84 103 0.78 2.03 2.02 84 105 0.75 0.83 84 107 1.14 85 72 0.91 DEG CHN 104 P2 115 P2 114 P2 122 P2 118 P2 126 P2 114 P2 121 P2 118 P2 121 P2 124 P2 113 P2 109 P2 114 P2 114 P2 114 P2 119 P2 116 P2 112 P2 106 P2 112 P2 109 P2 109 P2 109 P2 107 P2 103 P2 109 P2 113 P2 113 P2 114 P2 115 P2 113 P2 111 P2 113 P2 107 P2 100 P2 108 P2 114 P2 113 P2 113 P2 103 P2 114 P2 110 P2 109 P2 126 P2 124 P2 108 P2 118 P2 120 P2 115 P2 118 P2 114 P2 I11 P2 121 P2 115 P2 123 P2 117 P2 112 P2 118 P2 114 P2 115 P2 115 P2 119 P2 116 P2 116 P2 118 P2 113 P2 109 P2 121 P2 116 P2 119 P2 111 P2 113 P2 112 P2 104 P2 101 P2 102 P2 106 P2 102 P2 117 P2 IND %TW TWD 20 TWD 25, TWD 24 TWD 22 TWD 26 TWD 22 TWD 32 TWD 25 TWD 29 TWD 25 TWD 21 TWD 24 TWD 22 TWD 26 TWD 31 TWD 20 TWD 27 TWD 20 TWD 23 TWD 20 TWD 20 TWD 26 TWD 21 TWD 20 TWD 31 TWD 21 TWD 31 TWD 27 TWD 21 TWD 24 TWD 20 TWD 26 TWD 28 TWD 26 TWD 20 TWD 22 TWD 28 TWD 30 TWD 32 TWD 27 TWD 20 TWD 26 TWD 23 TWD 25 TWD 22 TWD 23 TWD 22 TWD 20 TWD 22 TWD 26 TWD 27 TWD 33 TWD 33 TWD 25 TWD 21 TWD 21 TWD 20 TWD 23 TWD 23 TWD 21 TWD 24 TWD 24 TWD 21 TWD 23 TWD 29 TWD 26 TWD 29 TWD 23 TWD 26 TWD 28 TWD 25 TWD 29 TWD 30 TWD 21 TWD 33 TWD 33 TWD 20 TWD 21 TWD 26 TWD 23 LOCATION AV7

+0.00 AV5

+0.00 AV4

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV5

+0.00 AV3

+0.00 AV5

+0.00 AV6

-0.18 AV7

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV7

-0.07 AV6

+0.00 AV5

-0.11 AV3

-0.07 AV3

-0.09 AV5

+0.00 AV6

-0.04 AV7

-0.13 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV6

+0.00 AV4

+0.00 AV3

+0.00 AV3

+0.00 AV4

+0.00 AV6

+0.00 AV5

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV6

+0.00 AV3

+0.00 AV4

+0.04 AV3

+0.11 AV5

+0.09 AV6

+0.07 AV7

+0.07 AV5

+0.00 AV3

+0.00 AV4

+0.00 AV6

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV4

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV2

+0.00 AV5

+0.00 AV5

+0.00 AV2

+0.00 AV4

+0.00 AV6

+0.00 AV7

+0.00 AV3

+0.00 AV2

+0.00 AV4

+0.00 AV3

+0.00 AV6

+0.00 AV3

+0.11 EXT EXT UTIL 1

UTIL 2

TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC CAL #

19 19 19 31 31 31 31 31 31 31 31 14 14 14 14 14 14 14 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 19 19 19 19 19 19 19 31 31 29.

13 13 13 13 13 13 11 11 11 11 18 18 18 18 18 18 18 18 18 18 18 20 20 20 20 20 30 30 30 30 30 30 13 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD PROBE 610UL 61OUL 610UDL 610UL 61OUL 610UL 61OUL 61OUL 61OUL 610UL 610UL 61OUL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UDL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:37:52 Component: S/G A Page 4 of 21 Component: S/C A Page 4 of 21 Bobbin AVB Wear Indications 20% to 100%

(Degraded Tubes)

QUERY: QueryMl, Enc. 1 Page4of21 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.90 0.99 85 74 1.43 85 76 0.99 1.67 85 84 1.16 1.40 85 86 0.84 0.96 1.22 85 88 0.74 85 92 0.75 0.84 85 94 1.01 0.97 85 96 0.96 85 98 0.92 1.49 85 104 0.85 1.18 1.31 0.83 85 106 0.74 85 110 1.02 86 71 0.84 0.97 86 73 1.70 86 75 1.42 86 77 0.73 1.19 0.96 86 81 1.35 86 85 1.14 1.20 1.30 86 87 0.94 0.81 86 89 0.74 0.69 0.98 86 91 0.86 0.72 0.98 86 93 1.15 1.08 0.89 0.60 86 95 1.16 1.79 0.67 0.92 86 103 0.71 87 80 0.78 0.69 87 82 0.69 0.69 0.81 87 84 0.67 1.05 0.81 87 86 0.77 0.88 1.15 87 88 0.70 0.67 87 90 0.96 0.86 87 92 1.14 0.88 1.35 0.69 87 94 0.75 1.43 1.61 1.00 87 96 0.83 1.37 87 98 0.96 1.52 1.36 DEG CHN 114 P2 119 P2 112 P2 119 P2 115 P2 120 P2 118 P2 114 P2 118 P2 116 P2 120 P2 114 P2 115 P2 118 P2 118 P2 121 P2 123 P2 111 P2 107 P2 109 P2 109 P2 112 P2 111 P2 109 P2 116 P2 125 P2 110 P2 110 P2 116 P2 112 P2 117 P2 119 P2 113 P2 116 P2 112 P2 113 P2 109 P2 111 P2 109 P2 110 P2 114 P2 114 P2 106 P2 114 P2 109 P2 110 P2 110 P2 108 P2 109 P2 114 P2 112 P2 126 P2 124 P2 119 P2 122 P2 121 P2 121 P2 121 P2 116 P2 122 P2 108 P2 107 P2 108 P2 109 P2 113 P2 106 P2 105 P2 115 P2 113 P2 109 P2 109 P2 114 P2 106 P2 111 P2 112 P2 104 P2 107 P2 108 P2 106 P2 108 P2 IND %TW TWD 23 TWD 24 TWD 29 TWD 24 TWD 32 TWD 25 TWD 28 TWD 22 TWD 23 TWD 27 TWD 20 TWD 20 TWD 22 TWD 24 TWD 24 TWD 23 TWD 24 TWD 30 TWD 22 TWD 26 TWD 27 TWD 21 TWD 20 TWD 26 TWD 22 TWD 24 TWD 32 TWD 29 TWD 20 TWD 27 TWD 24 TWD 29 TWD 27 TWD 27 TWD 28 TWD 26 TWD 24 TWD 23 TWD 22 TWD 26 TWD 25 TWD 22 TWO 26 TWD 29 TWD 28 TWD 25 TWD 20 TWD 29 TWD 34 TWD 22 TWD 26 TWD 20 TWD 22 TWD 20 TWD 20 TWD 20 TWD 22 TWD 20 TWD 25 TWD 22 TWD 23 TWD 25 TWD 28 TWD 22 TWD 21 TWD 26 TWD 25 TWD 28 TWD 25 TWD 31 TWD 22 TWD 23 TWD 31 TWD 33 TWD 27 TWD 24 TWD 31 TWD 27 TWD 33 TWD 31 LOCATION AV4

+0.11 AV5

+0.13 AV8

+0.09 AV5

+0.04 AV6

+0.09 AV5

+0.00 AV6

+0.00 AV3

+0.00 AV6

+0.00 AV7

+0.00 AV5

+0.00 AV7

+0.00 AV5

+0.00 AV5

+0.00 AV4

+0.00 AV6

+0.00 AV3

+0.00 AV4

-0.13 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV3

+0.00 AV5

+0.00 AV5

+0.00 AV6

+0.35 AV6

+0.33 AV2

-0.18 AV5

+0.35 AV6

-0.15 AV7

+0.00 AV5

+0.00 AV4

-0.18 AV5

-0.20 AV6

+0.37 AV4

+0.00 AV3

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV6

+0.04 AV5

-0.02 AV4

-0.09 AV6

+0.00 AVS

+0.00 AV4

+0.00 AV3

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV2

+0.00 AV4

+0.29 AV6

-0.20 AV3

+0.30 AV4

+0.28 AV7

+0.32 AV4

+0.29 AV5

+0.00 AV6

+0.00 AV6

+0.00 AV5

+0.00 AV3

+0.00 AV5

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV3

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV4

+0.00 AV3

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL 13 13 13 13 13 11 11 18 18 18 18 18 18 18 18 18 20 20 30 30 30 30 30 29 14 14 14 14 14 14 14 12 12 12 12 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 31 12 12 12 12 12 12 12 12 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 19 19 19

  1. LEG COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 61OUL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 6100L 61OUL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 61OUL 610UL 61OUL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:37:52 Component: S/G A Page 5 of 21 Component: S/C A Page 5 of 21 Bobbin AVB Wear Indications 20% to 100%

(Degraded Tubes)

QUERY: QueryMl, Enc. 1 Page 5 of 21 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 1.18 1.96 87 100 0.74 0.78 87 102 0.65 0.95 1.93 1.67 87 104 1.14 1.21 0.79 1.00 87 108 0.65 0.63 88 73 0.99 88 83 0.84 88 91 0.88 0.71 88 93 0.90 88 95 1.14 1.05 88 99 0.74 88 103 0.82 0.97 0.76 88 105 0.85 0.92 89 76 0.88 1.11 1.39 89 84 1.31 89 86 1.11 1.84

0. 92 1.29 1.19 89 88 1.15 1.24 1.20 1.15 89 90 1.03 0.74 1.20 89 92 0.92 89 94 1.21 0.91 89 98 1.13 2.09 89 102 0.67 90 69 0.91 90 71 0.90 90 77 0.72 90 81 0.96 1.05 90 85 0.97 0.96 90 87 0.60 0.72 90 89 0.98 1.16 90 91 0.72 0.63 0.64 0.72 90 93 1.54 1.44 0.67 90 95 0.81 0.72 0.87 1.81 0.63 90 97 0.57 0.58 0.97 90 101 0.80 1.00 0.96 1.04 91 74 1.00 DEG CHN 115 P2 110 P2 110 P2 111 P2 108 P2 115 P2 105 P2 111 P2 118 P2 122 P2 126 P2 117 P2 110 P2 112 P2 118 P2 113 P2 111 P2 118 P2 119 P2 115 P2 113 P2 117 P2 110 P2 108 P2 11 P2 112 P2 102 P2 116 P2 114 P2 117 P2 119 P2 114 P2 110 P2 119 P2 118 P2 115 P2 114 P2 112 P2 117 P2 115 P2 119 P2 120 P2 116 P2 113 P2 118 P2 115 P2 113 P2 108 P2 117 P2 118 P2 116 P2 121 P2 121 P2 121 P2 123 P2 114 P2 107 P2 112 P2 115 P2 108 P2 112 P2 101 P2 110 P2 105 P2 109 P2 113 P2 112 P2 110 P2 109 P2 105 P2 114 P2 106 P2 114 P2 113 P2 116 P2 112 P2 109 P2 113 P2 111 P2 117 P2 IND %TW TWD 29 TWD 36 TWD 23 TWD 24 TWD 22 TWD 27 TWD 35 TWD 34 TWD 26 TWD 27 TWD 22 TWD 25 TWD 21 TWD 20 TWD 24 TWD 21 TWD 22 TWD 20 TWD 23 TWD 26 TWD 25 TWD 21 TWD 21 TWD 23 TWD 20 TWD 22 TWD 23 TWD 23 TWD 26 TWD 29 TWD 27 TWD 25 TWD 32 TWD 23 TWD 27 TWD 26 TWD 26 TWD 27 TWD 26 TWD 26 TWD 24 TWD 20 TWD 26 TWD 23 TWD 26 TWD 23 TWD 26 TWD 34 TWD 20 TWD 23 TWD 23 TWD 20 TWD 22 TWD 23 TWD 22 TWD 22 TWD 20 TWD 22 TWD 26 TWD 29 TWD 22 TWD 21 TWD 21 TWD 22 TWD 32 TWD 31 TWD 22 TWD 24 TWD 22 TWD 25 TWD 34 TWD 21 TWD 20 TWD 20 TWD 27 TWD 24 TWD 27 TWD 27 TWD 28 TWD 25 LOCATION AV4

+0.00 AV3

+0.00 AV3

+0.00 AV4

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.11 AV3

+0.00 AV6

+0.00 AV4

+0.00 AV6

+0.00 AV4

+0.00 AV3

+0.00 AV6

+0.00 AV6

+0.00 AV5

+0.00 AV3

+0.00 AV5

+0.00 AV4

+0.00 AV5

+0.07 AV6

+0.07 AV7

+0.09 AV7

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV3

+0.00 AV3

+0.00 AV7

+0.00 AV5

+0.00 AV5

+0.00 AV3

-0.02 AV4

+0.00 AV6

+0.15 AV6

+0.15 AV6

+0.11 AV5

+0.00 AV6

+0.00 AV5

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV5

+0.00 AV6

-0.04 AV5

-0.02 AV4

-0.07 AV3

-0.07 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV5

+0.00 AV3

+0.00 AV2

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV6

+0.15 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC UTIL 1

UTIL 2

CAL #

19 19 19 19 19 19 19 19 31 31 31 31 29 29 13 11 18 18 18 18 18 20 30 30 30 30 30 13 13 13 11 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 20 20 20 15 13 13 11 11 11 11 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 19 19 19 19 19 19 19 1

LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD PROBE 610UL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 610TDL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TDL 610UL 610UL 610UL 610UL 610UDL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:37:52 Component: S/G A Page 6 of 21 Bobbin AVB Wear Indications 20% to 100%

(Degraded Tubes)

QUERY: QueryMl, Enc. 1 Page 6 of 21 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 91 78 1.08 1.14 91 84 1.20 1.28 0.84 1.38 91 86 1.96 0.83 1.00 0.87 0.74 91 88 1.55 0.61 1.00 91 90 0.81 1.03 0.79 91 92 1.06 0.74 0.67 1.27 91 94 0.89 0.59 0.99 0.69 91 98 0.83 0.85 91 102 0.56 1.05 0.52 91 104 0.68 0.75 1.10 0.63 0.58 91 110 0.57 92 71 1.18 1.52 1.06 92 73 1.44 0.82 92 75 0.80 0.77 92 77 1.86 0.66 2.39 92 81 1.06 1.24 0.78 92 83 0.65 0.95 1.11 92 85 1.05 0.78 92 87 0.64 92 89 0.80 92 91 0.83 0.77 0.60 0.81 92 93 1.21 1.08 1.11 92 95 1.35 0.93 1.76 2.09 92 97 0.92 1.35 2.00 1.27 92 103 1.21 0.90 0.54 93 72 0.83 93 74 0.88 0.75 93 76 1.11 0.68 93 84 1.00 DEG CHN 119 P2 122 P2 120 P2 118 P2 121 P2 114 P2 107 P2 109 P2 112 P2 116 P2 107 P2 109 P2 117 P2 115 P2 113 P2 114 P2 110 P2 112 P2 104 P2 114 P2 107 P2 115 P2 114 P2 114 P2 115 P2 114 P2 111 P2 118 P2 116 P2 114 P2 115 P2 118 P2 113 P2 111 P2 117 P2 114 P2 116 P2 112 P2 118 P2 l15 P2 123 P2 120 P2 124 P2 111 P2 117 P2 116 P2 124 P2 120 P2 126 P2 121 P2 122 P2 119 P2 114 P2 119 P2 118 P2 106 P2 111 P2 108 P2 112 P2 117 P2 115 P2 110 P2 112 P2 112 P2 107 P2 113 P2 110 P2 111 P2 106 P2 105 P2 112 P2 110 P2 109 P2 118 P2 117 P2 112 P2 116 P2 116 P2 112 P2 111 P2 IND %TW TWO 26 TWO 27 TWO 28 TWO 29 TWO 23 TWO 30 TWO 35 TWO 24 TWO 27 TWD 25 TWD 23 TWD 33 TWD 21 TWO 27 TWO 24 TWO 27 TWO 23 TWO 27 TWO 23 TWO 21 TWO 30 TWO 25 TWO 20 TWD 26 TWO 22 TWO 24 TWO 24 TWO 21 TWO 29 TWO 20 TWO 23 TWO 24 TWD 29 TWD 22 TWD 21 TWO 21 TWD 27 TWO 31 TWO 26 TWD 30 TWO 23 TWO 22 TWO 22 TWD 34 TWO 20 TWO 37 TWO 26 TWO 28 TWO 22 TWO 20 TWD 25 TWD 27 TWD 26 TWD 22 TWO 21 TWO 24 TWO 24 TWO 23 TWO 20 TWO 24 TWO 29 TWD 28 TWO 28 TWO 31 TWO 26 TWO 34 TWO 36 TWO 26 TWO 30 TWD 35 TWD 30 TWO 30 TWO 27 TWO 20 TWO 22 TWO 23 TWD 21 TWO 26 TWO 20 TWO 25 LOCATION AV4

+0.04 AVS

+0.02 AV4

+0.02 AVS

+0.09 AV6

+0.11 AV7

+0.09 AV7

+0.00 AV6

+0.00 AVS

+0.00 AV4

+0.00 AV3

+0.00 AV7

+0.00 AV5

+0.00 AV4

+0.00 AV7

+0.00 AV6

+0.00 AVS

+0.00 AV7

+0.00 AV6

+0.00 AV4

+0.00 AV3

+0.00 AV7

+0.00 AVS

+0.00 AV4

+0.00 AV2

+0.00 AV4

+0.00 AV3

+0.00 AV5

+0.00 AV4

+0.00 AV2

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AVS

+0.00 AVS

+0.00 AV6

+0.00 AV7

+0.00 AV3

+0.00 AV6

+0.00 AV7

+0.04 AV8

+0.00 AV3

+0.13 AV4

+0.02 AVG

+0.00 AV3

+0.15 AV4

+0.09 AV5

+0.09 AV3

+0.11 AVS

+0.09 AV6

+0.13 AV3

+0.18 AV4

+0.07 AV5

+0.00 AV4

+0.00 AV6

+0.00 AVS

+0.00 AV4

+0.00 AV3

+0.00 AV6

+0.00 AV5

+0.00 AV3

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV6

+0.00 AVS

+0.00 AV6

+0.00 AV7

-0.22 AVS

+0.35 AV6

+0.00 AV2

+0.33 EXT EXT UTIL 1

UTIL 2

TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEC TEN TEC TEN TEC TEH TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEE TEC TEN TEC TEE TEC TEN TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEE TEC TEH TEC TEH TEC TEE TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEN TEC TEH TEC TEH TEC TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TER TEC TEN TEC TEN TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEE TEC TEN TEC TEH TEC TEE TEC TEH TEC TEH TEN TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC CAL # LEG 1

=COLD 1

COLD 1

COLD 1

COLD 1

COLD 1

COLD 15 NOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 11 HOT 11 HOT 11 HOT 11 HOT 11 HOT 11 HOT 11 HOT 11 HOT 11 HOT 3

COLD 3

COLD 3

COLD 1

COLD 1

COLD 1

COLD 1

COLD 1

COLD 1

COLD 1

COLD 1

COLD 1

COLD 1

COLD 1

COLD 1

COLD 1

COLD 1

COLD 1

COLD 15 HOT 15 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 11 HOT 11 HOT 11 HOT 2

COLD 2

COLD 2

COLD 2

COLD 2

COLD 2

COLD PROBE 610UL 61OUL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610DL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:37:52 Component: S/G A Page 7 of 21 Bobbin AVB Wear Indications 20% to 100%

(Degraded Tubes)

QUERY: QueryMl, Enc. 1 Page 7 of 21 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 1.17 0.83 0.81 1.29 93 86 1.04 1.59 1.22 93 88 1.06 93 90 1.45 0.93 1.46 0.80 2.58 93 92 1.25 1.17 0.74 1.12 93 94 0.69 1.21 1.52 93 96 0.84 1.01 1.35 93 102 1.03 94 71 1.08 94 73 0.68 0.71 0.77 0.73 94 75 1.18 0.85 1.00 94 83 2.23 2.06 1.73 2.31 0.86 94 87 0.85 1.06 94 89 1.62 1.60 1.11 1.27 94 91 0.61 0.66 0.94 94 93 0.69 2.03 1.23 1.11 0.80 94 95 0.64 0.92 0.69 94 99 1.09 0.70 0.77 94 103 0.59 1.09 0.97 94 105 0.53 0.68 95 72 0.81 0.85 1.04 0.74 95 76 0.86 1.16 95 82 0.87 0.77 95 84 1.14 0.86 95 86 0.62 1.08 1.74 1.68 0.94 95 88 0.87 0.93 0.99 DEG 114 110 107 109 118 113 116 116 116 121 114 119 105 114 120 122 120 114 114 114 122 121 119 121 116 123 125 119 122 119 119 123 108 105 107 110 110 129 114 107 113 112 109 111 109 107 112 i1 109 110 108 114 115 ill 110 110 114 112 116 108 118 119 121 120 127 123 118 125 127 117 120 110 112 110 114 107 106 109 114 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW LOCATION 27 AV4 22 AV5 22 AV6 28 AV7 25 AV4 30 AV5 27 AV6 25 AV7 29 AV4 24 AV5 1

29 AV6 1

22 AV7

+

35 AV3 1

27 AV3

+

26 AV4

+

21 AV5 1

26 AV6

+

20 AV2

+

27 AV3

+

30 AV4

+

22 AV3

+

25 AV4

+

28 AV5

+

24 AV4 26 AV7 1

20 AV5

+

21 AV6 22 AV7

+

21 AV8

+

28 AV5

+

23 AV6

+

25 AV7

+

35 AV3

+

34 AV4

+

32 AV5

+

36 AV6 23 AV7 22 AV5

+

25 AV6

+

33 AV6

+

33 AV5

+

28 AV4

+

30 AV3

+

20 AV5

+

21 AV4 9

26 AV3

+

22 AV7

+

36 AV6

+

29 AV5

+

28 AV3

+

24 AV2

+

21 AV7

+

26 AV6

+

22 AV3

+

28 AV6

+

22 AV5

+

23 AV4

+

21 AV2

+

29 AV3

+

28 AV4

+

20 AV4

+

23 AV5

+

22 AV2

+

23 AV4 26 AV5 1

21 AV6

+

23 AV5

+

27 AV6 1

23 AV4 22 AV5

+

27 AV4

+

23 AV5

+

21 AV7

+

28 AV6 34 AV5 1

33 AV4 26 AV3

+

25 AV7 26 AV6 27 AV5

-0.24

-0.00

+0.00

+0.00 10.00 0.00

+0.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00 r0.00

+0.00 10.00

+0.00 r0.00

+0.00 0.00 10.00 10.00 10.00 10.00 10.07 10.11

+0.07 10.31 10.00 10.00

-0.20

-0.18

0. 00 0.00
0. 00 10.00
0. 00 10.00 10.00 10.00 0.00 10.00 10.00
0. 00 10.00
0. 00 0.00 0.00 0.00 10.00 0.00 10.00 0.00 10.00 0.00 10.00 0.00 10.00 10.00 10.00 10.00 10.11 r0.02 10.07 10.02 10.02 r0.09 10.00 10.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00 EXT TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC EXT TEC TEC TEC TEC TEN TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEN TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEN TEH TEH TEH TEH TEH TEH TEH UTIL 1

UTIL 2

CAL 2

2 2

16 16 16 16 14 14 14 14 OWS 36 14 14 14 14 14 14 14 14 14 14 12 4

1 1

1 1

1 1

1 2

2 2

2 2

16 16 15 15 15 15 13 13 13 13 13 13 13 13 13 13 13 13 13 13 11 11 11 11 11 1

1 1

1 1

1 1

1 1

1 15 15 15 15 15 15 15 15

  1. LEG COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 61OUL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610DL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 61OUL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:37:52 Component: S/G A Page 8 of 21 Component: S/C A Page 8 of 21 Bobbin AVB Wear Indications 20% to 100%

(Degraded Tubes)

QUERY: QueryMl, Enc. 1 Page 8 of 21 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.91 95 90 0.60 0.99 0.98 0.65 0.65 95 92 1.41 1.37 0.62 1.05 0.87 95 94 0.84 0.92 0.67 1.22 95 96 0.62 0.60 0.62 95 98 0.65 95 102 0.91 0.91 1.27 95 104 0.54 96 77 0.89 0.74 0.96 96 79 0.76 96 83 1.80 1.57 1.42 1.91 96 85 1.81 1.94 1.61 96 87 1.08 1.94 1.25 0.93 0.58 96 89 2.10 1.35 1.62 2.24 0.74 96 91 0.84 0.79 0.80 96 93 2.68 1.38 0.96 1.36 97 76 0.70 0.95 97 82 0.85 97 84 1.36 1.65 0.92 97 86 0.82 1.28 1.60 97 88 0.92 1.44 0.87 1.50 97 90 0.84 1.23 1.15 1.31 97 92 1.18 1.85 0.79 1.14 1.31 1.07 97 98 0.88 0.80 0.69 97 100 0.78 97 102 0.92 0.992 DEG 113 114 111 117 102 106 ill 115 112 110 110 113 1il 110 110 115 115 112 117 116 114 115 122 123 124 110 117 117 118 120 110 112 115 118 113 115 118 114 114 120 120 ill 122 123 124 118 105 ill 123 119 108 114 105 108 110 110 123 116 120 121 120 121 114 122 117 117 115 118 ill 121 116 119 114 119 127 129 124 118 123 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWD 26 TWD 20 TWD 26 TWD 26 TWD 21 TWD 21 TWD 31 TWD 31 TWD 20 TWD 27 TWD 25 TWD 24 TWD 25 TWD 21 TWD 29 TWD 20 TWD 20 TWD 20 TWD 21 TWD 27 TWD 27 TWD 31 TWD 20 TWD 24 TWD 21 TWD 25 TWD 21 TWD 33 TWD 32 TWD 30 TWD 34 TWD 34 TWO 34 TWD 32 TWD 28 TWD 35 TWD 30 TWD 26 TWD 20 TWD 34 TWO 28 TWD 30 TWD 34 TWD 20 TWD 22 TWD 22 TWD 22 TWD 36 TWD 28 TWD 24 TWD 28 TWD 20 TWD 24 TWD 22 TWD 29 TWD 31 TWD 24 TWD 22 TWD 27 TWD 30 TWD 23 TWD 29 TWD 22 TWD 29 TWD 22 TWD 27 TWD 26 TWD 28 TWD 27 TWD 32 TWD 21 TWD 26 TWD 28 TWD 25 TWO 23 TWO 22 TWD 20 TWD 20 TWD 22 TWD 22 LOCATION AV4

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV5

+0.00 AV3

+0.00 AV6

+0.00 AV3

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.11 AV5

+0.13 AV6

+0.09 AV6

-0.20 AV3

+0.11 AV4

+0.04 AV5

+0.09 AV6

+0.09 AV3

+0.15 AV5

+0.07 AV6

+0.15 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00

,AV7

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV5

+0.00 AV6

-0.15 AV4

+0.33 AV7

+0.33 AV5

+0.04 AV6

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV6

+0.00 AV2

+0.00 AV3

+0.00 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL 15 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 11 11 11 11 1

1 1

2 1

1 1

1 1

1 1

15 15 15 15 15 16 16 16 16 16 14 14 14 OWS 36 14 14 14 2

2 2

2 2

1 16 16 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 12 12 12

  1. LEG PROBE HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 610UL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 610UL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL NOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 610UL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:37:52 Component: S/G A Page 9 of 21 Bobbin AVB Wear Indications 20% to 100%

(Degraded Tubes)

QUERY: QueryMi, Enc. 1 Page 9 of 21 PSL-ENC-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.81 0.79 97 104 1.86 1.24 2.55 98 73 0.65 98 75 0.88 98 77 1.00 0.80 0.93 98 79 1.44 98 81 0.67 98 83 2.67 0.79 1.68 1.75 98 87 0.71 1.00 1.86 2.46 1.56 2.40 98 89 2.96 1.38 1.55 2.26 1.50 98 91 1.16 1.57 0.83 0.61 98 93 0.70 1.12 98 95 1.24 1.09 98 99 0.66 98 101 0.52 98 103 0.84 1.27 1.01 0.59 99 74 0.91 99 76 0.72 99 84 2.05 1.66 1.12 99 86 2.09 2.18 1.44 1.61 1.74 1.73 99 88 1.02 1.10 0.90 1.34 99 90 1.96 0.91 0.78 0.98 1.00 99 92 1.71 1.57 1.06 1.26 0.59 99 94 0.80 1.13 0.89 1.72 99 96 0.61 0.90 99 102 2.48 1.39 1.95 100 73 0.98 100 75 0.85 100 81 0.74 0.85 0.78 DEG CHN 121 P2 119 P2 114 P2 119 P2 109 P2 117 P2 125 P2 112 P2 114 P2 114 P2 116 P2 126 P2 109 P2 109 P2 112 P2 110 P2 115 P2 122 P2 119 P2 112 P2 117 P2 105 P2 107 P2 109 P2 112 P2 108 P2 110 P2 109 P2 104 P2 105 P2 113 P2 109 P2 107 P2 113 P2 109 P2 107 P2 110 P2 11 P2 114 P2 116 P2 117 P2 117 P2 120 P2 110 P2 113 P2 121 P2 105 P2 107 P2 107 P2 114 P2 109 P2 106 P2 107 P2 111 P2 108 P2 108 P2 108 P2 106 P2 108 P2 110 P2 105 P2 110 P2 113 P2 113 P2 114 P2 108 P2 109 P2 113 P2 106 P2 105 P2 110 P2 106 P2 105 P2 108 P2 102 P2 110 P2 109 P2 113 P2 106 P2 109 P2 IND %TW LOCATION TWD 21 AV6

+0.00 TWD 21 AV7

+0.00 TWD 31 AV2

+0.00 TWD 26 AV4

+0.00 TWD 35 AV3

+0.00 TWD 20 AV7

+0.00 TWD 24 AV7

+0.00 TWD 25 AV4

+0.00 TWD 22 AV5

+0.00 TWD 24 AV6

+0.00 TWD 30 AV3

+0.07 TWD 20 AV3

+0.11 TWD 36 AV6

+0.00 TWD 21 AV3

+0.31 TWD 32 AV4

+0.33 TWD 32 AV5

+0.31 TWD 20 AV2

+0.00 TWD 24 AV3

+0.00 TWD 32 AV4

+0.00 TWD 35 AV6

+0.00 TWD 30 AV7

+0.00 TWD 34 AV5

+0.00 TWD 37 AV6

+0.00 TWD 31 AV3

+0.00 TWD 33 AV4

+0.00 TWD 37 AV5

+0.00 TWD 32 AV7

+0.00 TWD 29 AV7

+0.00 TWD 32 AV6

+0.00 TWD 24 AV5

+0.00.

TWD 20 AV2

+0.00 TWD 22 AV6

+0.00 TWD 28 AV4

+0.00 TWD 29 AV4

+0.00 TWD 28 AV2

+0.00 TWD 21 AV3

+0.00 TWD 20 AV6

+0.00 TWD 26 AV2

+0.00 TWD 31 AV3

+0.00 TWD 28 AV4

+0.00 TWD 21 AVS

+0.00 TWD 24 AV6

+0.00 TWD 21 AV5

+0.11 TWD 35 AV3

+0.04 TWD 32 AV4

-0.02 TWD 27 AV5

+0.07 TWD 36 AV7

+0.00 TWD 36 AV6

+0.00 TWD 32 AV5

+0.00 TWD 33 AV4

+0.00 TWD 34 AV3

+0.00 TWD 34 AV2

+0.00 TWD 27 AV7

+0.00 TWD 28 AV4

+0.00 TWD 26 AV3

+0.00 TWD 31 AV2

+0.00 TWD 35 AV7

+0.00 TWD 25 AV6

+0.00 TWD 23 AV5

+0.00 TWD 26 AV4

+0.00 TWD 27 AV3

+0.00 TWD 34 AV7

+0.00 TWD 32 AV6

+0.00 TWD 27 AV5

+0.00 TWD 30 AV3

+0.00 TWD 20 AV2

+0.00 TWD 24 AV8

+0.00 TWD 28 AV5

+0.00 TWD 25 AV4

+0.00 TWD 34 AV3

+0.00 TWD 20 AV4

+0.00 TWD 25 AV3

+0.00 TWD 35 AV3

+0.00 TWD 32 AV5

+0.00 TWD 36 AV4

+0.00 TWD 24 AV7

-0.18 TWD 22 AV2

+0.31 TWD 21 AV5

+0.00 TWD 22 AV6

+0.00 TWD 21 AV7

-0.26 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC UTIL 1

UTIL 2

CAL 12 12 12 12 12 1

1 2

2 2

1 1

DWS 36 2

2 2

16 16 16 16 16 DWS 36 DWS 36 15 15 15 15 13 13 13 13 13 13 13 13 13 11 11 11 11 11 1

1 1

1 1

15 15 15 15 15 15 15 15 15 15 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 DWS 36 11 11 2

2 2

2 2

  1. LEG HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD HOT COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD PROBE 61OUL 61OUL 61OUL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:37:52 Component: S/G A Page 10 of 21 Bobbin AVB Wear Indications 20% to 100%

(Degraded Tubes)

QUERY: QueryMl, Enc. 1 Page 10 of 21 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 100 83 0.77 1.57 1.44 1.13 100 85 0.84 1.54 2.35 2.06 0.72 2.58 100 87 1.43 1.43 1.66 1.37 100 89 0.75 1.65 1.78 2.40 100 91 0.72 0.75 0.84 100 93 1.49 0.78 1.30 100 101 0.83 100 103 0.83 0.92 1.12 101 76 0.71 101 80 0.82 0.80 101 82 1.09 101 84 1.24 1.54 1.83 0.74 101 86 0.98 0.85 1.03 1.07 0.91 1.06 101 88 0.88 1.39 101 90 0.89 1.24 1.08 101 92 1.34 1.18 0.97 0.81 101 96 0.78 101 104 0.85 102 75 0.82 102 81 0.84 1.14 1.74 102 83 0.87 2.63 1.74 1.10 102 85 2.48 1.18 1.83 102 87 1.00 1.00 1.23 1.86 102 89 0.94 1.80 1.15 0.97 102 91 0.78 1.14 102 93 1.79 1.02 0.60 102 95 0.79 103 74 1.00 1.23 DEG CHN 116 P2 116 P2 115 P2 119 P2 118 P2 113 P2 107 P2 111 P2 119 P2 109 P2 108 P2 106 P2 115 P2 113 P2 125 P2 121 P2 120 P2 112 P2 116 P2 119 P2 121 P2 114 P2 116 P2 118 P2 122 P2 119 P2 119 P2 119 P2 110 P2 111 P2 108 P2 111 P2 108 P2 107 P2 103 P2 104 P2 117 P2 114 P2 117 P2 121 P2 116 P2 116 P2 122 P2 108 P2 118 P2 116 P2 122 P2 122 P2 118 P2 117 P2 122 P2 121 P2 121 P2 120 P2 118 P2 121 P2 119 P2 107 P2 109 P2 109 P2 110 P2 108 P2 115 P2 110 P2 120 P2 121 P2 117 P2 114 P2 117 P2 107 P2 117 P2 115 P2 112 P2 108 P2 107 P2 113 P2 115 P2 113 P2 114 P2 113 P2 IND %TW TWD 22 TWD 32 TWD 30 TWD 27 TWD 23 TWD 31 TWD 37 TWD 35 TWD 21 TWD 38 TWD 31 TWD 31 TWD 33 TWD 31 TWD 21 TWD 31 TWD 32 TWD 35 TWD 20 TWD 21 TWD 22 TWD 29 TWD 21 TWD 28 TWD 21 TWD 21 TWD 22 TWD 25 TWD 20 TWD 22 TWD 22 TWD 26 TWD 28 TWD 30 TWD 33 TWD 21 TWD 24 TWD 22 TWD 25 TWD 25 TWD 23 TWD 25 TWD 23 TWD 28 TWD 23 TWD 27 TWD 25 TWD 28 TWD 27 TWD 24 TWD 22 TWD 21 TWD 21 TWD 23 TWD 23 TWD 27 TWD 33 TWD 23 TWD 37 TWD 32 TWD 26 TWD 38 TWD 28 TWD 34 TWD 24 TWD 24 TWD 27 TWD 32 TWD 26 TWD 34 TWD 29 TWD 27 TWD 23 TWD 28 TWD 34 TWD 27 TWD 20 TWD 23 TWD 25 TWD 28 LOCATION AV2

+0.07 AV4

+0.04 AV5

+0.11 AV6

+0.07 AV2

+0.11 AV3

+0.13 AV4

+0.09 AV5

+0.02 AV6

+0.11 AV7

+0.04 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV6

+0.00 AV3

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV4

+0.00 AV5

+0.00 AV6

-0.20 AV4

+0.29 AV6

-0.22 AV6

+0.00 AV5

+0.11 AV6

-0.20 AV7

+0.09 AV2

+0.35 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV3

+0.00 AV6

+0.00 AV3

+0.00 AVS

+0.00 AV7

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV3

+0.00 AV4

+0.00 AV7

+0.00 AV3

+0.13 AV4

+0.09 AV5

+0.18 AV3

+0.30 AV4

+0.00 AV5

+0.33 AV6

+0.00 AV2

+0.09 AV5

+0.02 AV6

+0.09 AV2

+0.00 AV4

+0.00 AV6

+0.00 AV7

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV6

-0.04 AV5

+0.00 AV4

+0.00 AV6

+0.00 AV4

+0.00 AV3

+0.00 AV6

+0.00 AV2

+0.00 AV3

+0.00 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC UTIL 1

UTIL 2

CAL 1

1 1

1 1

1 1

1 1

1 15 15 15 15 16 16 16 16 14 14 14 14 14 14 12 12 12 12 2

2 2

2 2

2 2

2 16 16 16 16 16 16 16 16 14 14 14 14 14 14 14 14 12 1

1 1

1 2

2 2

2 1

1 1

16 16 16 16 15 15 15 15 13 13 13 13 13 13 1

1

  1. LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD PROBE 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 61OUL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 6100L 61OUL 61OUL 610UL 61OUL 6100L 61OUL 61OUL 61OUL 61OUL 610UL 610UL 61OUL 61OUL 61OUL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:37:52 Component: S/G A Page 11 of 21 Bobbin AVB Wear Indications 20% to 100%

(Degraded Tubes)

QUERY: QueryMl, Enc. 1 Page 11 of 21 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 103 76 1.04 0.65 1.29 0.67 103 78 0.65 0.79 0.91 103 82 0.65 0.80 1.25 1.32 103 84 0.90 0.95 1.78 1.49 103 86 1.75 0.83 1.17 1.00 0.98 103 88 1.06 1.96 1.01 0.85 103 90 1.11 1.04 0.67 103 92 1.09 1.07 0.61 1.47 103 94 0.59 0.64 104 73 0.72 104 77 0.67 104 83 0.73 2.06 1.81 1.84 104 85 0.76 0.68 1.54 0.72 104 89 1.27 3.04 1.80 1.95 1.74 104 91 0.84 0.69 0.74 0.74 104 93 1.33 1.51 105 82 0.70 0.75 0.86 105 84 2.28 1.48 0.88 1.61 105 86 1.24 1.18 1.32 1.22 2.69 105 88 0.69 1.31 0.83 1.17 2.48 105 90 0.76 1.51 1.65 1.58 105 92 2.21 0.88 0.95 105 94 1.35 0.97 DEG 116 121 113 121 127 119 122 122 119 117 117 122 114 109 115 112 111 113 ill 114 108 112 ill 108 106 109 110 114 110 113 115 116 114 118 119 117 119 115 109 104 107 109 121 103 114 115 119 117 116 114 122 116 119 108 110 107 103 107 i1 108 117 124 120 124 103 117 119 121 125 118 123 118 115 112 113 122 119 115 118 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWD 26 TWD 20 TWD 29 TWD 20 TWD 20 TWD 22 TWD 24 TWD 20 TWD 22 TWD 28 TWD 29 TWD 24 TWD 25 TWD 33 TWD 31 TWD 34 TWD 24 TWD 29 TWD 27 TWD 27 TWD 28 TWD 35 TWD 27 TWD 25 TWD 28 TWD 27 TWD 21 TWD 28 TWD 27 TWD 20 TWD 32 TWD 20 TWD 21 TWD 20 TWD 20 TWD 21 TWD 35 TWD 34 TWD 34 TWD 21 TWD 20 TWD 30 TWD 20 TWD 27 TWD 38 TWD 32 TWD 33 TWD 31 TWD 22 TWD 20 TWD 21 TWD 21 TWD 28 TWD 30 TWD 20 TWD 21 TWD 23 TWD 36 TWD 30 TWD 23 TWD 31 TWD 27 TWD 26 TWD 28 TWD 27 TWD 36 TWD 20 TWD 28 TWD 22 TWD 26 TWD 35 TWD 21 TWD 30 TWD 31 TWD 30 TWD 34 TWD 23 TWD 24 TWD 28 TWD 24 LOCATION AV3

+0.04 AV5

+0.09 AV6

-0.04 AV7

+0.11 AV3

+0.11 AV4

+0.07 AV5

+0.09 AV4

+0.11 AV5

+0.07 AV6

+0.13 AV7

+0.11 AV2

+0.09 AV5

+0.07 AV6

+0.02 AV7

+0.09 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV3

+0.00 AV7

+0.00 AV5

+0.00 AV4

+0.00 AV7

+0.00 AV6

+0.00 AV4

+0.00 AV3

+0.00 AV5

+0.00 AV3

+0.00 AV4

+0.00 AV6

+0.07 AV3

+0.09 AV4

+0.09 AV5

+0.20 AV6

+0.07 AV2

-0.18 AV4

-0.24 AV6

+0.00 AV7

-0.18 AV7

+0.00 AV6

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV5

+0.00 AV6

+0.00 AV3

+0.00 AV4

+0.00 AV5

-0.22 AV2

+0.33 AV3

+0.33 AV6

+0.04 AV7

+0.28 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV7

+0.00 AV6

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV3

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV3

+0.00 AV4

+0.00 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL #

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 15 15 15 15 15 15 15 15 15 13 13 13 13 13 13 13 13 13 2

1 1

1 1

1 2

2 2

16 DWS 36 16 16 16 14 14 14 14 14 14 2

2 2

2 2

2 2

16 16 16 16 DWS 36 16 16 16 16 16 14 14 14 14 14 14 14 14 14 LEG PROBE COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 610UL HOT 61OUL HOT 61OUL HOT 610UL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL HOT 610UL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 610UL HOT 61OUL HOT 610UL HOT 61OUL HOT 61OUL HOT 61OUL HOT 610UL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:37:52 Component: S/G A Page 12 of 21 Component: S/S A Page 12 of 21 Bobbin AVB Wear Indications 20% to 100%

(Degraded Tubes)

QUERY: QueryMl, Enc. 1 Page 12 of 21 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.75 106 75 0.75 0.76 106 79 0.73 0.91 106 81 0.67 1.61 0.75 106 83 1.02 1.35 2.37 2.64 1.45 106 87 1.18 1.92 2.35 1.46 1.64 2.98 106 89 2.80 1.18 1.21 106 91 1.01 1.47 1.57 1.22 0.58 106 93 0.70 0.61 106 97 0.77 106 101 0.60 107 72 1.27 107 74 0.74 0.67 107 80 1.27 2.66 0.82 0.78 107 82 1.20 1.95 1.29 0.82 107 86 0.61 0.66 0.80 107 88 1.33 2.50 0.60 0.63 1.27 107 90 1.59 1.23 1.55 0.60 107 92 1.38 0.69 1.66 2.47 107 94 0.70 0.96 0.68 107 96 0.62 107 98 0.67 107 102 0.79 108 71 0.94 108 75 1.34 108 77 0.71 0.86 108 81 0.72 108 83 0.97 1.72 2.06 2.23 108 85 2.46 2.83 0.85 0.91 108 87 0.87 0.73 1.53 DEG 122 123 125 123 122 127 115 123 110 ill 109 108 114 113 110 110 110 108 107 104 117 108 109 110 112 ill 102 113 104 114 112 116 121 120 120 109 117 117 118 113 119 121 106 108 105 108 108 117 108 ill 109 108 111 11i 114 111 109 ill 112 ill 112 Iill 115 119 115 109 127 118 ill 118 116 118 114 107 109 119 119 120 123 120 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW LOCATION TWD 21 AVS

+0.00 TWD 21 AV6

+0.09 TWD 22 AV7

+0.00 TWD 21 AV5

+0.13 TWD 24 AV6

+0.00 TWD 20 AV4

+0.09 TWD 32 AV6

-0.02 TWD 21 AV7

-0.02 TWD 25 AV2

+0.28 TWD 29 AV3

+0.31 TWD 36 AV4

+0.00 TWD 37 AV5

+0.37 TWD 30 AV6

+0.00 TWD 29 AV7

+0.00 TWD 35 AV6

+0.00 TWD 37 AV4

+0.00 TWD 32 AV3

+0.00 TWD 33 AV2

+0.00 TWD 37 AVS

+0.00 TWD 36 AV6

+0.00 TWD 29 AV7

+0.00 TWD 29 AV5

+0.00 TWD 27 AV7

+0.00 TWD 32 AV6

+0.00 TWD 32 AV5

+0.00 TWD 29 AV4

+0.00 TWD 20 AV3

+0.00 TWD 22 AV6

+0.00 TWD 20 AV5

+0.00 TWD 23 AV3

+0.00 TWD 21 AV4

+0.00 TWD 29 AV5

+0.00 TWD 21 AV2

+0.00 TWD 20 AV3

+0.00 TWD 29 AV2

+0.09 TWD 38 AV3

+0.13 TWD 23 AV6

-0.02 TWD 22 AV7

+0.04 TWD 28 AV4

+0.07 TWD 35 AV5

+0.07 TWD 29 AV6

+0.04 TWD 23 AV7

-0.02 TWD 21 AV7

+0.00 TWD 22 AV4

+0.00 TWD 24 AV3

+0.00 TWD 31 AV7

+0.00 TWD 38 AV6

+0.00 TWD 20 AV5

+0.00 TWD 21 AV4

+0.00 TWD 30 AV3

+0.00 TWD 33 AV7

+0.00 TWD 29 AV6

+0.00 TWD 32 AV5

+0.00 TWD 20 AV4

+0.00 TWD 31 AV6

+0.00 TWD 22 AV5

+0.00 TWD 33 AV4

+0.00 TWD 38 AV3

+0.00 TWD 22 AV5

+0.00 TWD 26 AV4

+0.00 TWD 22 AV3

+0.00 TWD 20 AV7

+0.00 TWD 21 AV3

+0.00 TWD 25 AV3

+0.00 TWD 24 AV5

+0.00 TWD 29 AV5

+0.35 TWD 21 AV3

+0.15 TWD 23 AV6

+0.15 TWD 20 AV4

-0.24 TWD 25 AV3

+0.09 TWD 33 AV4

+0.07 TWD 35 AV5

+0.11 TWD 36 AV6

+0.04 TWD 38 AV6

+0.09 TWD 39 AV7

+0.04 TWD 23 AV2

+0.04 TWD 24 AV3

+0.15 TWD 22 AV2

+0.00 TWD 20 AV4

+0.00 TWD 30 AV5

+0.00 EXT EXT TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL #

14 1

1 1

1 1

1 1

2 2

2 2

2 15 15 15 15 15 DWS 36 DWS 36 15 15 13 13 13 13 13 13 13 13 11 1

1 1

1 1

1 1

1 1

1 1

15 15 15 15 15 15 15 15 13 13 13 13 13 13 13 13 13 13 13 13 13 11 4

2 1

1 2

1 1

1 1

1 1

1 1

16 16 16 LEG HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT PROBE 610UL 61OUL 61OUL 61OUL 61OUL 610UL 61OUL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 6100L 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:37:52 Component: S/G A Page 13 of 21 Bobbin AVB Wear Indications 20% to 100%

(Degraded Tubes)

QUERY: QueryMl, Enc. I Page 13 of 21 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 1.51 1.26 108 89 2.23 1.05 1.41 1.12 0.76 2.16 108 91 0.68 1.54 1.75 0.96 0.91 108 93 1.28 0.68 108 95 1.25 1.15 0.78 1.88 1.23 108 99 0.98 0.79 108 103 0.89 109 72 1.03 2.05 1.89 2.00 109 74 0.84 0.81 109 76 1.01 109 78 1.45 1.76 1.29 109 80 0.74 1.30 0.92 109 82 0.77 1.27 0.73 109 84 2.32 1.22 0.90 0.78 109 86 0.74 1.45 1.00 2.27 0.95 2.53 109 88 1.25 1.53 109 90 0.95 0.69 1.29 1.16 1.93 109 92 1.15 0.69 0.91 0.68 109 102 0.99 110 71 0.72 0.67 110 73 0.80 110 77 0.69 0.88 110 81 0.77 110 83 2.63 2.54 1.39 2.35 0.77 110 87 0.62 0.93 1.04 1.07 0.89 110 89 1.16 2.22 1.19 DEG CHN 118 P2 120 P2 113 P2 117 P2 118 P2 121 P2 118 P2 117 P2 120 P2 107 P2 109 P2 114 P2 114 P2 117 P2 117 P2 117 P2 116 P2 118 P2 il1 P2 113 P2 119 P2 121 P2 124 P2 108 P2 111 P2 113 P2 112 P2 114 P2 114 P2 111 P2 113 P2 112 P2 113 P2 112 P2 112 P2 113 P2 112 P2 113 P2 115 P2 110 P2 118 P2 119 P2 117 P2 123 P2 117 P2 125 P2 112 P2 124 P2 107 P2 121 P2 116 P2 125 P2 125 P2 122 P2 117 P2 109 P2 118 P2 120 P2 120 P2 115 P2 122 P2 121 P2 127 P2 121 P2 113 P2 118 P2 119 P2 105 P2 109 P2 112 P2 110 P2 111 P2 109 P2 110 P2 108 P2 112 P2 113 P2 109 P2 110 P2 106 P2 IND %TW LOCATION TWO 30 AV6 TWO 27 AV7 TWO 34 AV5 TWO 25 AV6 TWO 29 AV7 TWO 26 AV8 TWO 21 AV3 TWO 34 AV4 TWO 20 AV2 TWO 30 AV3 TWO 31 AV4 TWO 24 AV5 TWO 23 AV6 TWO 28 AV3 TWO 20 AV4 TWO 27 AV2 TWO 26 AV3 TWO 21 AV4 TWO 32 AV6 TWO 27 AV7 TWO 24 AV2 TWO 22 AV3 TWO 22 AV3 TWO 25 AV5 TWO 34 AV6 TWO 33 AV7 TWO 34 AV8 TWD 22 AV5 TWO 22 AV6 TWD 25 AV4 TWD 30 AV2 TWO 32 AV3 TWO 28 AV5.

TWO 21 AV2 TWO 28 AV5 TWD 23 AV6 TWO 21 AV2 TWD 28 AV3 TWO 20 AV5 TWD 37 AV2 TWD 28 AV3 TWD 24 AV5 TWO 22 AV7 TWO 20 AV2 TWO 29 AV3 TWO 24 AV4 TWD 34 AV5 TWO 24 AV6 TWO 35 AV7 TWO 27 AV6 TWO 30 AV7 TWO 24 AV3 TWO 20 AV4 TWD 28 AV5 TWD 26 AV6 TWD 33 AV7 TWO 26 AV3 TWO 20 AV4 TWO 23 AV6 TWD 20 AV7 TWO 23 AV3 TWO 21 AV2 TWO 20 AV3 TWO 22 AV2 TWO 20 AV3 TWO 23 AV4 TWO 22 AV5 TWO 36 AV5 TWO 36 AV6 TWD 29 AV3 TWO 36 AV4 TWO 21 AV7 TWO 21 AV7 TWO 26 AV6 TWO 27 AV5 TWO 28 AV4 TWO 25 AV3 TWO 29 AV5 TWO 37 AV4 TWO 29 AV3

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00 F0.00

+0.00

+0.00

+0.00 F0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

-0.00

+0.00

+0.00 0.40

-0.00

+0.22

+0.00

+0.33

-0.15

+0.31

-0.18

+0.31

+0.00

+0.31

-0.18

-0.15

+0.33 0.00

-0.18

+0.17

+0.07 0.04 r0.11 0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

-0.00

+0.00

+0.00

+0.00

+0.00 0.00

+0.00

+0.00

+0.00

+0.00 r0.00

+0.00

+0.00

+0.00

+0.15

+0.00

+0.00

+0.00

+0.00

-0.18

+0.00

+0.00

-0.00

+0.00

-0.00

[0.00

+0.00

+0.00 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL 16 16 16 16 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 12 2

2 2

2 2

2 2

2 2

2 2

2 2

22 1

1 1

1 16 16 16 16 16 16 16 14 14 14 14 14 14 14 14 14 12 3

3 1

2 2

1 DWS 36 DWS 36 2

2 2

15 15 15 15 15 15 15 15

  1. LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD HOT HOT COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610TDL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610DL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610DL 610UL 610UL

AREVA NP Inc 12/14/12 11:37:52 Customer Name: St Lucie 2 Replacement Component: S/G A Page 14 of 21 Bobbin AVB Wear Indications 20% to 100%, Enc. 1 Page 14 of 21 (Degraded Tubes)

PSL-ENG-SESJ-12-006 Rev. 0 QUERY: QueryMl EC # 278014 Rev. 0 ROW COL VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1

UTIL 2

CAL # LEG PROBE 110 91 1.82 107 P2 TWD 34 AV6

-0.02 TEC TEH 13 HOT 610UL 1.38 109 P2 TWD 31 AV5

+0.00 TEC TEH 13 HOT 61OUL 2.07 103 P2 TWD 36 AV4

+0.00 TEC TEH 13 HOT 61OUL 0.96 106 P2 TWD 26 AV3

+0.02 TEC TEH 13 HOT 61OUL 0.77 109 P2 TWD 23 AV2

+0.00 TEC TEH 13 HOT 61OUL 110 93 0.82 112 P2 TWD 24 AV2

+0.00 TEC TEH 13 HOT 61OUL 0.76 106 P2 TWD 23 AV6

+0.00 TEC TEH 13 HOT 61OUL 0.72 110 P2 TWD 22 AV5

+0.00 TEC TEH 13 HOT 61OUL 1.06 111 P2 TWD 27 AV4

+0.00 TEC TEH 13 HOT 61OUL 1.01 110 P2 TWD 27 AV3

+0.00 TEC TEH 13 HOT 610UL 110 95 0.59 106 P2 TWD 20 AV7

+0.00 TEC TEH 13 HOT 61OUL 1.22 106 P2 TWD 29 AV6

+0.00 TEC TEH 13 HOT 61OUL 0.61 109 P2 TWD 20 AV3

+0.00 TEC TEH 13 HOT 61OUL 0.96 111 P2 TWD 26 AV2

+0.00 TEC TEH 13 HOT 61OUL 110 101 0.69 120 P2 TWD 23 AV4

+0.00 TEC TEH 11 HOT 61OUL 110 103 0.70 112 P2 TWD 23 AV3

+0.00 TEC TEH 11 HOT 61OUL 111 78 0.90 121 P2 TWD 24 AV3

+0.07 TEH TEC 1

COLD 61OUL 0.68 124 P2 TWD 20 AV4

+0.09 TEH TEC 1

COLD 61OUL 1.06 125 P2 TWD 26 AV5

+0.07 TEH TEC 1

COLD 61OUL 0.68 121 P2 TWD 20 AV6

-0.04 TEH TEC 1

COLD 61OUL 11 80 1.15 119 P2 TWD 27 AV5

+0.07 TEH TEC 1

COLD 61OUL 111 82 0.87 119 P2 TWD 23 AV4

+0.15 TEH TEC 1

COLD 61OUL 1.16 119 P2 TWD 27 AV5

+0.13 TEH TEC 1

COLD 61OUL 111 84 1.79 105 P2 TWD 32 AV2

+0.33 TEH TEC 2

COLD 61OUL 1.88 105 P2 TWD 33 AV3

+0.00 TEH TEC 2

COLD 61OUL 0.71 108 P2 TWD 20 AV4

-0.20 TEH TEC 2

COLD 61OUL 1.65 108 P2 TWD 31 AV5

+0.37 TEH TEC 2

COLD 61OUL 1.98 110 P2 TWD 34 AV6

+0.37 TEH TEC 2

COLD 61OUL 2.51 106 P2 TWD 37 AV7

+0.09 TEH TEC 2

COLD 61OUL 111 86 0.60 105 P2 TWD 20 AV6

+0.00 TEC TEH 15 HOT 610UL 1.19 117 P2 TWD 29 AV5

+0.00 TEC TEH 15 HOT 610UL 1.64 112 P2 TWD 33 AV4

+0.00 TEC TEH 15 HOT 610UL 1.04 108 P2 TWD 28 AV3

+0.00 TEC TEH 15 HOT 61OUL 1.21 108 P2 TWD 29 AV2

+0.00 TEC TEH 15 HOT 61OUL 11 90 0.70 114 P2 TWD 22 AV7

+0.00 TEC TEH 13 HOT 61OUL 1.90 107 P2 TWD 35 AV6

+0.00 TEC TEH 13 HOT 61OUL 1.79 112 P2 TWD 34 AV5

+0.00 TEC TEH 13 HOT 61OUL 1.10 113 P2 TWD 28 AV4

+0.00 TEC TEH 13 HOT 61OUL 1.11 114 P2 TWD 28 AV3

+0.00 TEC TEH 13 HOT 61OUL 111 92 1.54 112 P2 TWD 32 AV6

+0.00 TEC TEH 13 HOT 61OUL 0.69 114 P2 TWD 22 AV5

+0.00 TEC TEH 13 HOT 61OUL 1.48 112 P2 TWD 32 AV4

+0.00 TEC TEH 13 HOT 61OUL 1.31 114 P2 TWD 30 AV3

+0.00 TEC TEH 13 HOT 61OUL 1.07 112 P2 TWD 27 AV2

+0.00 TEC TEH 13 HOT 61OUL 111 94 0.68 109 P2 TWD 22 AV6

+0.00 TEC TEH 13 HOT 61OUL 0.59 111 P2 TWD 20 AV5

+0.00 TEC TEH 13 HOT 61OUL 0.79 109 P2 TWD 23 AV3

+0.00 TEC TEH 13 HOT 61OUL 11 96 1.05 115 P2 TWD 27 AV4

+0.00 TEC TEH 13 HOT 61OUL 2.58 107 P2 TWD 38 AV3

+0.00 TEC TEH 13 HOT 61OUL 0.67 111 P2 TWD 21 AV2

+0.00 TEC TEH 13 HOT 61OUL 111 102 0.91 112 P2 TWD 27 AV3

+0.00 TEC TEH 11 HOT 61OUL 0.53 120 P2 TWD 20 AV2

+0.00 TEC TEH 11 HOT 61OUL 112 73 0.73 109 P2 TWD 20 AV4

+0.00 TEH TEC 2

COLD 610UL 112 79 0.79 113 P2 TWD 21 AV3

+0.00 TEH TEC 2

COLD 61OUL 112 81 0.74 109 P2 TWD 21 AV5

+0.33 TEH TEC 2

COLD 61OUL 0.78 110 P2 TWD 21 AV6

+0.31 TEH TEC 2

COLD 61OUL 112 83 0.69 125 P2 TWD 20 AV3

+0.07 TEH TEC 1

COLD 610UL 1.60 117 P2 TWD 32 AV4

+0.07 TEH TEC 1

COLD 610UL 0.77 123 P2 TWD 22 AV5

+0.09 TEH TEC 1

COLD 61OUL 0.87 119 P2 TWD 23 AV6

+0.02 TEH TEC 1

COLD 61OUL 0.69 119 P2 TWD 20 AV7

+0.00 TEH TEC 1

COLD 61OUL 112 85 1.86 113 P2 TWD 34 AV3

+0.15 TEH TEC 1

COLD 61OUL 0.98 115 P2 TWD 25 AV4

+0.09 TEH TEC 1

COLD 61OUL 1.71 114 P2 TWD 33 AV5

+0.07 TEH TEC 1

COLD 61OUL 2.93 108 P2 TWD 40 AV7

+0.04 TEH TEC 1

COLD 61OUL 112 87 0.91 121 P2 TWD 23 AV2

+0.00 TEC TEH 16 HOT 61OUL 1.33 117 P2 TWD 28 AV3

+0.00 TEC TEH 16 HOT 61OUL 0.82 128 P2 TWD 22 AV4

+0.00 TEC TEH 16 HOT 61OUL 1.00 125 P2 TWD 24 AV5

+0.00 TEC TEH 16 HOT 61OUL 1.89 112 P2 TWD 32 AV6

+0.00 TEC TEH 16 HOT 61OUL 1.57 116 P2 TWD 30 AV7

+0.00 TEC TEH 16 HOT 61OUL 112 89 1.42 115 P2 TWD 29 AV2

+0.00 TEC TEH 16 HOT 61OUL 1.46 116 P2 TWD 29 AV3

+0.00 TEC TEH 16 HOT 610UL 2.24 115 P2 TWD 34 AV4

+0.00 TEC TEH 16 HOT 61OUL 1.28 120 P2 TWD 27 AV5

+0.00 TEC TEH 16 HOT 61OUL 2.10 116 P2 TWD 33 AV6

+0.00 TEC TEH 16 HOT 61OUL 0.79 121 P2 TWD 21 AV7

+0.00 TEC TEH 16 HOT 61OUL 112 91 1.09 119 P2 TWD 25 AV2

+0.00 TEC TEH 14 HOT 61OUL 1.88 113 P2 TWD 32 AV3

+0.00 TEC TEH 14 HOT 61OUL 1.17 115 P2 TWD 26 AV4

+0.00 TEC TEH 14 HOT 61OUL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:37:52 Component: S/G A Page 15 of 21 Bobbin AVB Wear Indications 20% to 100%

(Degraded Tubes)

QUERY: QueryMl, Enc. 1 Page 15 of 21 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.82 112 93 0.69 1.08 0.92 112 95 0.72 1.08 112 99 0.84 1.20 112 101 0.84 113 76 0.78 113 78 1.05 1.24 1.05 113 80 0.69 113 82 1.77 1.60 1.20 113 84 0.65 2.81 0.81 0.80 1.61 2.00 2.92 113 86 1.00 1.11 2.07 1.58 1.56 0.85 113 88 1.06 1.01 0.60 1.11 0.57 113 90 0.74 0.82 1.33 1.06 1.24 113 92 0.96 1.37 1.20 0.98 113 104 0.86 114 73 0.81 0.91 1.05 114 77 0.88 114 81 1.13 114 83 1.63 0.93 1.85 0.88 1.42 1.23 114 85 1.56 1.23 2.00 1.69 1.14 114 87 0.82 1.35 1.40 114 89 0.75 1.88 1.80 2.02 1.74 1.66 0.93 114 91 0.82 1.54 1.52 0.61 0.84 114 93 0.59 114 101 0.65 115 74 1.26 1.28 DEG 123 120 119 123 118 112 118 115 122 109 107 110 112 104 108 108 108 125 112 122 116 120 114 108 119 118 114 114 121 119 109 110 102 115 106 126 119 118 116 110 119 115 120 117 119 117 119 118 112 120 112 116 113 ill 112 110 112 118 113 113 118 112 114 106 120 110 114 107 113 109 ill 107 108 110 106 103 109 114 117 116 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWD 22 TWD 20 TWD 25 TWD 23 TWD 20 TWD 25 TWD 22 TWD 27 TWD 21 TWD 21 TWD 25 TWD 28 TWD 25 TWD 20 TWD 32 TWD 31 TWD 27 TWD 20 TWD 39 TWD 22 TWD 22 TWD 32 TWD 35 TWD 40 TWD 24 TWD 26 TWD 33 TWD 30 TWD 30 TWD 22 TWD 28 TWD 27 TWD 20 TWD 28 TWD 20 TWD 21 TWD 22 TWD 28 TWD 25 TWD 27 TWD 24 TWD 28 TWD 27 TWD 24 TWD 22 TWD 22 TWD 24 TWD 26 TWD 23 TWD 27 TWD 31 TWD 24 TWD 33 TWD 23 TWD 29 TWD 27 TWD 32 TWD 28 TWD 35 TWD 33 TWD 27 TWD 24 TWD 31 TWD 31 TWD 23 TWD 35 TWD 34 TWD 36 TWD 34 TWD 33 TWD 26 TWD 24 TWD 32 TWD 32 TWD 20 TWD 24 TWD 20 TWD 22 TWD 29 TWD 29 LOCATION AV6

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV2

+0.00 AV6

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV3

-0.18 AV4

-0.18 AV5

-0.18 AV7

+0.26 AV6

+0.00 AV3

+0.00 AV5

-0.15 AV6

+0.38 AVI

+0.07 AV2

+0.15 AV3

+0.04 AV4

+0.11 AV5

+0.20 AV6

+0.15 AV7

+0.09 AV2

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV8

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV6

+0.00 AV3

+0.00 AV3

+0.00 AV4

+0.00 AV6

+0.00 AV3

+0.15 AV3

+0.07 AV2

+0.31 AV3

-0.20 AV4

+0.07 AV5

+0.00 AV6

+0.00 AV7

-0.15 AV3

+0.09 AV4

+0.04 AV5

+0.02 AV6

+0.11 AV7

+0.09 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV8

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV5

+0.00 AV4

+0.00 AV2

+0.00 AV3

+0.00 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC UTIL 1

UTIL 2

CAL #

14 14 14 14 14 14 14 14 12 2

2 2

2 2

2 2

2 1

1 1

1 1

1 1

16 16 16 16 16 16 15 15 15 15 15 14 14 14 14 14 14 14 14 14 12 1

1 1

2 1

2 2

2 2

2 2

1 1

1 1

1 15 15 15 15 15 15 15 15 15 15 13 13 13 13 13 13 1

1 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD PROBE 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610OL 610UL 610UL 610UL 610UL 610OL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 61OUL 610DL 610UL 610UL 610UL 610UL 6100L 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610DL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610DL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610OL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:37:53 Component: S/G A Page 16 of 21 Bobbin AVB Wear Indications 20% to 100%

(Degraded Tubes), Enc. 1 Page 16 of 21 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 QUERY: QueryMl ROW COL VOLTS 115 78 0.86 115 80 0.74 1.06 115 82 1.16 0.67 1.23 115 84 0.95 1.97 2.11 2.47 1.32 1.68 115 86 1.60 1.65 0.80 0.82 1.84 115 88 1.44 1.22 1.48 2.05 2.69 115 90 0.59 1.27 1.09 0.94 0.68 115 92 0.84 1.26 115 102 1.15 116 79 0.95 1.09 1.06 1.56 0.91 116 81 0.78 0.83 1.06 1.07 116 85 3.24 3.13 1.14 1.99 0.88 1.58 116 87 1.94 1.29 1.31 0.90 116 89 0.79 1.88 1.50 1.38 1.98 3.02 116 91 0.94 0.69 116 93 0.75 0.72 116 95 0.91 117 78 1.44 0.89 0.73 117 80 0.78 117 82 2.86 1.12 1.13 0.91 1.11 1.46 0.95 117 86 1.88 1.88 1.70 1.24 117 88 1.97 0.91 1.26 117 90 0.82 1.73 DEG 121 122 118 118 121 117 109 104 105 108 109 110 113 110 114 112 104 116 118 116 116 104 110 112 107 108 108 105 109 110 116 112 113 108 108 110 ill 110 113 101 103 107 104 109 110 117 121 118 126 119 119 121 120 119 106 124 121 118 128 125 110 109 113 112 105 112 108 112 108 109 ill 119 120 119 116 112 112 113 118 116 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW LOCATION TWD 23 AV3

+0.04 TWD 21 AV5

+0.09 TWD 26 AV6

-0.07 TWD 27 AV3

+0.00 TWD 20 AV4

+0.02 TWD 28 AV5

-0.02 TWD 24 AV2

+0.31 TWD 34 AV3

+0.00 TWD 35 AV4

-0.20 TWD 36 AV5

+0.00 TWD 28 AV6

-0.13 TWD 32 AV7

+0.31 TWD 33 AV7

+0.00 TWD 33 AV6

+0.00 TWD 24 AV5

+0.00 TWD 24 AV4

+0.00 TWD 35 AV2

+0.00 TWD 29 AV2

+0.00 TWD 27 AV3

+0.00 TWD 29 AV5

+0.00 TWD 33 AV7

+0.00 TWD 36 AV6

+0.00 TWD 20 AV6

+0.00 TWD 30 AV5

+0.00 TWD 28 AV4

+0.00 TWD 26 AV3

+0.00 TWD 22 AV2

+0.00 TWD 24 AV5

+0.00 TWD 30 AV4

+0.00 TWD 30 AV3

+0.00 TWD 24 AV2

+0.26 TWD 26 AV3

+0.29 TWD 25 AV5

+0.26 TWD 31 AV6

+0.33 TWD 23 AV7

+0.26 TWD 21 AV3

+0.00 TWD 22 AV4

-0.20 TWD 25 AV5

+0.33 TWD 26 AV6

+0.00 TWD 39 AV5

+0.00 TWD 38. AV6

+0.00 TWD 26 AV2

+0.33 TWD 34 AV3

+0.33 TWD 23 AV4

+0.09 TWD 31 AV7

-0.18 TWD 33 AVS

+0.00 TWD 28 AV6

+0.00 TWD 28 AV3

+0.00 TWD 23 AV4

+0.00 TWD 21 AV2

+0.00 TWD 32 AV3

+0.00 TWD 29 AV4

+0.00 TWD 28 AV5

+0.00 TWD 33 AV7

+0.00 TWD 38 AV6

+0.00 TWD 24 AV5

+0.00 TWD 20 AV6

+0.00 TWD 21 AV3

+0.00 TWD 20 AV5

+0.00 TWD 23 AV5

+0.00 TWD 30 AV3

+0.26 TWD 23 AV4

+0.00 TWO 21 AV6

+0.42 TWD 21 AV6

-0.18 TWD 37 AV6

+0.00 TWD 26 AV2

+0.31 TWD 26 AV3

+0.00 TWD 23 AV4

+0.29 TWD 26 AV5

-0.22 TWD 30 AV7

+0.24 TWD 24 AV8

-0.22 TWD 32 AV4

+0.00 TWD 32 AV5

+0.00 TWD 31 AV6

+0.00 TWD 27 AV2

+0.00 TWD 35 AV6

+0.00 TWD 26 AV5

+0.00 TWD 30 AV4

+0.00 TWD 22 AV6

+0.00 TWD 31 AV7

+0.00 EXT EXT TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEN TEC TEH TEN TEC TEH TEC TEH TEC TEH TEC TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEN TEC TEH TEC TEH TEC TEH TEC TEC TEN TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL 1

1 1

1 1

1 2

2 2

2 2

2 15 15 15 15 15 16 16 16 16 OWS 36 13 13 13 13 13 13 13 11 2

2 2

2 2

2 2

2 2

DWS 36 DWS 36 2

2 2

2 16 16 16 16 16 16 16 16 16 DWS 36 14 14 14 14 14 2

2 2

2 DWS 36 2

2 2

2 2

2 16 16 16 16 15 15 15 14 14

  1. LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD HOT COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 61OUL 610UL 61OUL 61OUL 610UL 610UL 61OUL 610UL 61OUL 61OUL 61OUL 61OUL 61OUL 610UL 610UL 61OUL 61OUL 61OUL 61OUL 610UL 61OUL 61OUL 61OUL 610UL 61OUL 61OUL 610UL 610UL 61OUL 61OUL 61OUL 610UL 61OUL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 61OUL 610UL 61OUL 61OUL 61OUL 610UL 61OUL 61OUL 610UL 61OUL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 61OUL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:37:53 Component: S/G A Page 17 of 21 Bobbin AVB Wear Indications 20% to 100%

(Degraded Tubes)

QUERY: QueryMl, Enc. 1 Page 17 of 21 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.79 1.23 1.65 117 92 0.78 0.78 117 94 1.02 0.75 118 81 1.31 1.09 118 83 0.74 1.41 1.94 2.04 1.21 118 87 1.69 2.09 1.12 1.61 1.59 118 89 1.17 0.57 0.98 0.85 2.64 2.99 118 91 0.66 0.95 0.64 0.85 118 95 2.17 0.82 119 80 0.67.

119 82 1.32 1.95 0.92 1.10 119 86 2.68 3.21 1.05 2.19 1.54 0.69 119 88 1.14 119 90 1.73 1.75 1.76 2.12 2.01 1.52 119 102 1.10 120 81 1.19 1.21 120 83 1.01 1.18 1.94 3.09 1.64 1.19 120 87 1.40 2.07 0.71 0.87 1.58 120 89 0.75 1.09 1.24 1.91 2.21 120 91 0.85 121 82 1.34 121 84 2.82 0.73 2.87 1.68 1.90 121 86 3.24 0.72 1.47 2.20 0.69 DEG 120 116 119 123 125 121 122 119 120 121 121 116 115 122 107 107 114 109 113 114 109 112 109 104 105 102 108 105 107 104 112 127 117 114 117 117 104 100 108 110 107 107 114 109 110 107 105 103 109 112 112 107 126 121 120 114 118 119 120 113 126 124 116 121 122 122 117 114 122 108 107 120 114 117 118 105 113 116 112 124 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW LOCATION TWD 21 AV3

+0.00 TWD 27 AV4

+0.00 TWD 31 AV5

+0.00 TWD 21 AV2

+0.00 TWD 21 AV4

+0.00 TWD 25 AV5

+0.00 TWD 21 AV6

+0.00 TWD 29 AV5

+0.11 TWD 27 AV6

+0.04 TWD 21 AV2

+0.02 TWD 30 AV4

+0.07 TWD 34 AV5

+0.09 TWD 35 AV6

+0.11 TWD 28 AV7

+0.04 TWD 33 AV6

+0.00 TWD 36 AV5

+0.00 TWD 28 AV4

+0.00 TWD 33 AV3

+0.00 TWD 33 AV2

+0.00 TWD 29 AV7

+0.00 TWD 20 AV5

+0.00 TWD 27 AV4

+0.00 TWD 25 AV2

+0.00 TWD 36 AV3

+0.00 TWD 37 AV6

+0.00 TWD 21 AV6

+0.00 TWD 26 AVS

+0.00 TWD 21 AV4

+0.00 TWD 24 AV3

+0.00 TWD 36 AV3

+0.00 TWD 24 AV2

+0.00 TWD 20 AV6

+0.04 TWD 29 AV3

+0.09 TWD 35 AV4

+0.13 TWD 24 AV5

-0.02 TWD 27 AV6

+0.07 TWD 36 AV5

+0.00 TWD 39 AV6

+0.00 TWD 28 AV7

+0.00 TWD 36 AV4

+0.00 TWD 32 AV3

+0.00 TWD 22 AV2

+0.00 TWD 26 AV4

+0.00 TWD 34 AV8

+0.00 TWD 34 AV7

+0.00 TWD 34 AV6

+0.00 TWD 36 AV4

+0.00 TWD 35 AV3

+0.00 TWD 32 AV2

+0.00 TWD 29 AV5

+0.00 TWD 27 AV5

+0.31 TWD 27 AV6

+0.00 TWD 26 AV2

+0.07 TWD 28 AV3

+0.02 TWD 35 AV4

+0.09 TWD 40 AV5

+0.09 TWD 32 AV6

+0.09 TWD 28 AV7

-0.04 TWD 29 AV2

+0.00 TWD 33 AV3

+0.00 TWD 20 AV4

+0.00 TWD 23 AV6

+0.00 TWD 30 AV7

+0.00 TWD 21 AV2

+0.00 TWD 25 AV3

+0.00 TWD 27 AV4

+0.00 TWD 32 AV5

+0.00 TWD 34 AV6

+0.00 TWD 22 AV5

+0.00 TWD 29 AV6

+0.24 TWD 39 AV2

+0.11 TWD 21 AV3

+0.09 TWD 39 AV5

+0.11 TWD 33 AV6

+0.07 TWD 34 AV7

+0.15 TWD 39 AV6

+0.00 TWD 20 AV2

+0.00 TWD 29 AV4

+0.00 TWD 34 AV5

+0.00 TWD 20 AV7

+0.00 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL #

14 14 14 14 14 14 14 1

1 1

1 1

1 1

15 15 15 15 15 15 15 15 15 DWS 36 DWS 36 13 13 13 13 13 13 1

1 1

1 1

DWS 36 DWS 36 15 15 15 15 16 13 13 13 13 13 13 11 2

2 1

1 1

1 1

1 16 16 16 16 16 16 16 16 16 16 14 2

1 1

1 1

1 DWS 36 16 16 16 16 LEG HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT NOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 61OUL 61OUL 61OUL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610DL 610UL 610UL 610UL 610UL 610DL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 6100L 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 61OUL 6100L 610UL 610UL 610DL 610DL 610UL 61OUL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:37:53 Component: S/G A Page 18 of 21 Component: S/C A Page 18 of 21 Bobbin AVB Wear Indications 20% to 100%

(Degraded Tubes)

QUERY: QueryMl, Enc. 1 Page 18 of 21 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 121 88 1.61 1.94 0.65 0.89 1.32 121 90 0.73 0.84 1.04 121 92 1.05 0.91 0.82 1.31 0.83 122 79 0.76 122 83 0.93 0.82 1.91 1.16 0.91 122 85 0.77 0.97 0.89 2.02 1.54 122 87 0.57 122 89 1.38 0.67 0.87 1.86 0.60 122 91 1.68 2.50 123 82 1.78 1.46 2.20 1.74 1.84 0.78 1.23 123 84 1.13 1.62 1.02 1.01 2.28 123 86 1.74 1.80 2.58 0.58 0.63 123 88 1.21 1.61 123 90 0.79 0.84 0.92 1.79 124 79 0.82 0.82 124 81 1.70 1.01 2.00 0.71 1.56 124 83 2.71 3.03 1.51 1.29 0.68 0.97 124 85 1.29 1.71 1.25 124 89 1.25 1.34 1.96 1.69 124 91 0.70 2.11 0.90 125 82 1.49 1.45 DEG 112 108 116 109 110 115 121 118 110 109 107 109 109 121 115 112 106 109 110 120 110 115 112 115 120 112 107 114 ill 114 110 106 116 116 116 116 110 124 117 102 109 112 112 101 114 107 104 104 103 116 117 113 104 99 104 106 ill 107 109 107 109 109 ill 112 112 119 120 126 106 107 110 117 116 116 116 124 ill 122 ill 105 CHN IND %TW LOCATIC P2 TWD 33 AV7 P2 TWD 35 AV6 P2 TWD 21 AV4 P2 TWD 25 AV3 P2 TWD 30 AV2 P2 TWD 20 AV3 P2 TWD 22 AV4 P2 TWD 25 AV6 P2 TWD 27 AV7 P2 TWD 25 AV6 P2 TWD 24 AV4 P2 TWD 30 AV3 P2 TWD 24 AV2 P2 TWD 22 AV3 P2 TWD 24 AV7 P2 TWD 22 AV2 P2 TWD 33 AV3 P2 TWD 27 AV4 P2 TWD 23 AV5 P2 TWD 22 AVI P2 TWD 25 AV3 P2 TWD 24 AV4 P2 TWD 35 AV5 P2 TWD 31 AV7 P2 TWD 20 AV6 P2 TWD 31 AV6 P2 TWD 22 AV5 P2 TWD 25 AV4 P2 TWD 35 AV3 P2 TWD 20 AV2 P2 TWD 33 AV5 P2 TWD 38 AV4 P2 TWD 33 AV2 P2 TWD 31 AV3 P2 TWD 36 AV4 P2 TWD 33 AV6 P2 TWD 34 AV7 P2 TWD 22 AV8 P2 TWD 28 AV5 P2 TWD 26 AV2 P2 TWD 31 AV4 P2 TWD 25 AV5 P2 TWD 25 AV6 P2 TWD 36 AV7 P2 TWD 34 AV6 P2 TWD 34 AV5 P2 TWD 38 AV4 P2 TWD 20 AV3 P2 TWD 21 AV2 P2 TWD 27 AV3 P2 TWD 30 AV5 P2 TWD 24 AV7 P2 TWD 24 AV6 P2 TWD 26 AV4 P2 TWD 34 AV3 P2 TWD 22 AV4 P2 TWD 22 AV5 P2 TWD 32 AV6 P2 TWD 25

  • AV2 P2 TWD 34 AV3 P2 TWD 20 AV4 P2 TWD 31 AV5 P2 TWD 39 AV2 P2 TWD 40 AV3 P2 TWD 31 AV4 P2 TWD 29 AV5 P2 TWD 20 AV6 P2 TWD 25 AV7 P2 TWD 28 AV4 P2 TWD 32 AV6 P2 TWD 28 AV7 P2 TWD 27 AV2 P2 TWD 28 AV3 P2 TWD 33 AV6 P2 TWD 31 AV7 P2 TWD 20 AV2 P2 TWD 34 AV4 P2 TWD 23 AV5 P2 TWD 30 AV4 P2 TWD 30 AV5

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.04

-0.15

+0.29

+0.33

+0.33

+0.42

+0.02

+0.11

+0.02

+0.04

+0.04

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.04

+0.02

-0.02

-0.02

+0.02

+0.00

+0.09

+0.29

-0.24

+0.00

+0.35

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

-0.26

+0.29

+0.00

+0.31

+0.29

-0.22

+0.31

+0.07

+0.07

+0.11

+0.20

+0.15

+0.07

+0.00

+0.33

+0.29

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.31

+0.11 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC UTIL 1

UTIL 2

CAL #

15 15 15 15 15 14 14 14 13 13 13 13 13 1

2 2

2 2

2 1

1 1

1 1

15 15 15 15 15 15 13 13 1

1 1

1 1

1 1

2 2

2 2

2 15 15 15 15 15 16 16 13 13 13 13 2

2 2

2 2

2 2

1 1

1 1

1 1

2 2

2 16 16 16 16 14 14 14 22 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT COLD COLD PROBE 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TDL 610TDL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610TDL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:37:53 Component:

S/G A Page 19 of 21 Component: S/C A Page 19 of 21 Bobbin AVB Wear Indications 20% to 100%

(Degraded Tubes)

QUERY: QueryMl, Enc. 1 Page 19 of 21 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 1.75 125 84 1.46 2.85

1. 67 1.36 1.65 125 86 3.11 0.80 0.81 1.71 125 88 1.23 1.03 0.65 1.31 125 90 0.88 0.90 125 92 0.87 0.75 126 81 0.65 1.28 0.94 126 83 2.07 1.50 126 85 1.55 0.77 0.67 1.45 1.40 126 87 2.16 1.66 0.74 0.70 126 89 2.71 1.57 1.64 0.80 0.78 0.73 126 91 1.22 0.92 1.75 0.95 127 78 0.90 1.16 127 82 1.54.

0.93 1.26 1.90 1.07 127 84 3.40 1.85 1.32 2.59 2.59 2.17 127 86 1.62 1.90 0.60 0.57 127 88 1.05 0.77 127 90 1.42 1.37 0.65 127 92 0.86 0.79 128 67 1.60 128 81 0.76 1.14 2.34 1.27 128 85 0.82 2.28 1.42 3.10 128 87 0.88 128 89 2.69 0.76 1.05 1.81 DEG CHN 109 P2 116 P2 103 P2 108 P2 119 P2 116 P2 107 P2 115 P2 122 P2 120 P2 108 P2 107 P2 117 P2 109 P2 115 P2 118 P2 110 P2 102 P2 125 P2 118 P2 121 P2 103 P2 112 P2 112 P2 121 P2 120 P2 118 P2 117 P2 107 P2 111 P2 117 P2 113 P2 105 P2 113 P2 107 P2 111 P2 114 P2 111 P2 114 P2 108 P2 108 P2 111 P2 121 P2 115 P2 119 P2 116 P2 117 P2 112 P2 122 P2 107 P2 108 P2 111 P2 103 P2 103 P2 107 P2 110 P2 110 P2 107 P2 110 P2 116 P2 121 P2 109 P2 110 P2 104 P2 120 P2 121 P2 114 P2 111 P2 112 P2 107 P2 112 P2 113 P2 108 P2 110 P2 101 P2 122 P2 106 P2 124 P2 119 P2 118 P2 IND %TW TWD 32 TWD 31 TWD 39 TWD 32 TWD 30 TWD 32 TWD 38 TWD 22 TWD 22 TWD 31 TWD 30 TWD 27 TWD 21 TWD 30 TWD 23 TWD 23 TWD 25 TWD 23 TWD 20 TWD 29 TWD 24 TWD 34 TWD 30 TWD 31 TWD 22 TWD 20 TWD 30 TWD 30 TWD 36 TWD 33 TWD 23 TWD 22 TWD 36 TWD 33 TWD 33 TWD 24 TWD 24 TWD 23 TWD 29 TWD 25 TWD 34 TWD 26 TWD 24 TWD 27 TWD 31 TWD 24 TWD 29 TWD 34 TWD 26 TWD 40 TWD 33 TWD 28 TWD 37 TWD 37 TWD 35 TWD 33 TWD 35 TWD 20 TWD 20 TWD 25 TWD 21 TWD 31 TWD 31 TWD 21 TWD 22 TWD 22 TWD 31 TWD 21 TWD 26 TWD 36 TWD 28 TWD 22 TWD 35 TWD 29 TWD 38 TWD 23 TWD 36 TWD 21 TWD 25 TWD 32 LOCATION AV6

-0.13 AV2

+0.11 AV3

+0.11 AV4

-0.04 AV5

+0.13 AV7

+0.11 AV6

+0.00 AV2

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV7

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV5

+0.00 AV5

+0.11 AV6

+0.00 AV7

+0.02 AV5

+0.31 AV7

-0.15 AV2

+0.07 AV3

+0.11 AV5

+0.09 AV6

+0.15 AV7

+0.11 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV2

+0.00 AV6

+0.00 AV7

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV3

+0.00 AV6

-0.04 AV7

+0.07 AV4

+0.11 AV5

+0.09 AV6

+0.04 AV7

+0.09 AV8

+0.09 AV5

+0.00 AV2

+0.33 AV3

+0.31 AV4

-0.20 AV6

+0.42 AV7

+0.33 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV3

+0.00 AV3

+0.00 AV6

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV2

+0.00 AV3

+0.00 AV3

+0.00 AV4

-0.24 AV5

+0.33 AV6

+0.00 AV7

-0.26 AV4

+0.00 AV5

-0.26 AV7

+0.09 AV6

+0.00 AV5

+0.00 AV6

+0.00 AV3

+0.00 AV5

+0.00 AV7

+0.00 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL #

2 1

1 1

1 1

DWS 36 16 16 16 15 15 15 15 14 14 13 13 1

1 1

2 2

1 1

1 1

1 15 15 15 15 DWS 36 15 15 15 15 15 13 13 13 13 1

1 1

1 1

1 1

DWS 36 2

2 2

2 2

15 15 15 15 16 16 13 13 13 14 14 4

2 2

2 22 2

DWS 36 16 DWS 36 16 16 16 LEG PROBE COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 610UL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL HOT 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 610UL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:37:53 Component: S/G A Page 20 of 21 Component: S/G A Page 20 of 21 Bobbin AVB Wear Indications 20% to 100%

(Degraded Tubes)

QUERY: QueryMl, Enc. 1 Page 20 of 21 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 128 91 0.89 1.51 1.11 1.92 0.76 128 93 0.91 129 80 0.88 129 82 1.08 0.78 0.99 1.18 129 84 3.20 1.45 1.42 0.83 1.76 1.80 129 88 1.41 129 90 1.72 1.56 129 92 0.96 1.32 1.29 1.16 1.31 130 67 0.84 1.07 0.72 130 83 1.19 1.03 2.80 0.84 1.38 130 85 2.31 1.45 1.75 2.90 130 87 2.03 2.14 0.59 0.66 130 89 1.06 1.08 0.81 130 91 0.62 0.82 0.98 0.94 130 93 0.64 1.49 0.90 130 95 0.66 131 80 1.03 0.84 131 84 1.31 1.34 3.35 131 86 0.90 1.46 131 88 0.80 0.73 131 90 2.50 1.15 2.57 131 92 1.32 131 94 0.61 132 67 0.74 0.86 132 83 1.21 0.96 1.80 132 89 1.63 0.75 132 91 2.74 0.99 2.24 1.41 132 93 0.86 132 103 1.36 0.58 DEG 116 119 120 114 126 117 110 108 103 106 ill 109 114 121 120 119 118 115 ill 112 ill 113 115 117 114 110 117 122 114

.123 121 ill 116 ill 106 108 107 122 113 118 114 116 113 113 114 105 118 1il 108 116 127 122 107 105 106 ill 108 123 122 106 109 101 116 109 120 118 108 110 ill 115 126 102 114 113 118 121 116 121 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW LOCATION 23 AV2 30 AV3 26 AV4 33 AV5 21 AV6 23 AV7 23 AV6 26 AV3 21 AV5 24 AV6 27 AV7 39 AV5 30 AV2 30 AV3 23 AV4 33 AV6 33 AV7 31 AV7 31 AV2 30 AV4 26 AV7 30 AV6 30 AV4 29 AV3 30 AV2 23 AV2 26 AV3 21 AV4 28 AV3 26 AV4 39 AV5 23 AV6 30 AV7 37 AV2 30 AV3 33 AV5 40 AV6 36 AV6 36 AV5 20 AV4 22 AV3 28 AV7 28 AV6 24 AV3 20 AV5 24 AV4 26 AV3 26 AV2 21 AV4 32 AV3 25 AV2 21 AV6 26 AV7 23 AV4 28 AV6 29 AV7 39 AV5 26 AV3 32 AV2 21 AV4 20 AV7 38 AV6 28 AV4 35 AV5 28 AV2 20 AV3 21 AV3 23 AV4 27 AV5 24 AV6 33 AV7 30 AV2 21 AV7 36 AV3 24 AV4 34 AV6 29 AV7 23 AV7 32 AV4 21 AV5

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00 0.20

+0.00

+0.35

-0.22

+0.26

+0.00

+0.13

+0.13

+0.00

+0.04

+0.07

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.04

+0.04

+0.11

+0.13

+0.02

+0.15

+0.09

+0.17

+0.15

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

-0.07

+0.09

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.31

+0.00

-0.16

+0.00

+0.00

+0.02

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL #

14 14 14 14 14 14 2

2 2

2 2

DWS 36 1

1 1

1 1

15 14 14 13 13 13 13 13 3

3 3

1 1

1 1

1 1

1 1

1 15 15 15 15 15 15 15 13 13 13 13 13 13 13 13 1

1 2

2 DWS 36 15 15 16 16 13 13 DWS 36 14 13 4

4 2

2 2

16 16 DWS 36 14 14 14 14 11 11 LEG HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD HOT COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 61OUL 61OUL 610UL 610UL 610UL 61OUL 61OUL 61OUL 61OUL 610UL 61OUL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:37:53 Component: S/G A Page 21 of 21 Component: S/G A Page 21 of 21 Bobbin AVB Wear Indications 20% to 100%

(Degraded Tubes)

QUERY: QueryMl, Enc. 1 Page 21 of 21 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 133 82 0.80 1.96 1.95 0.73 0.95 0.81 133 84 1.15 3.10 1.00 133 86 0.73 0.82 0.97 0.85 133 92 0.67 0.61 1.04 133 96 0.71 134 81 0.84 1.05 0.83 0.79 134 83 0.82 134 91 0.80 0.79 1.01 135 84 1.92 1.38 0.86 135 90 1.30 1.63 0.73 0.90 135 92 1.15 1.93 0.78 0.82 0.73 136 83 1.07 0.95 136 89 1.03 1.41 2.85 136 91 1.12 1.41 136 93 0.85 0.81 1.02 0.67 137 84 0.80 1.65 1.29 137 88 0.89 1.31 0.82 137 90 1.44 1.92 1.79 2.19 1.15 137 92 0.82 138 91 0.81 1.49 1.29 0.77 1.27 139 84 1.15 139 92 0.99 DEG CHN 115 P2 104 P2 113 P2 109 P2 108 P2 115 P2 114 P2 107 P2 118 P2 121 P2 117 P2 119 P2 121 P2 111 P2 109 P2 104 P2 120 P2 105 P2 107 P2 104 P2 99 P2 112 P2 104 P2 99 P2 105 P2 107 P2 113 P2 99 P2 103 P2 106 P2 114 P2 116 P2 108 P2 106 P2 105 P2 108 P2 115 P2 118 P2 125 P2 117 P2 118 P2 105 P2 119 P2 120 P2 119 P2 113 P2 115 P2 122 P2 104 P2 107 P2 106 P2 104 P2 113 P2 112 P2 115 P2 112 P2 115 P2 114 P2 118 P2 119 P2 113 P2 107 P2 106 P2 105 P2 105 P2 120 P2 105 P2 IND %TW TWD 22 TWD 34 TWD 34 TWD 20 TWD 24 TWD 22 TWD 27 TWD 40 TWD 25 TWD 20 TWD 22 TWD 24 TWD 22 TWD 21 TWD 20 TWD 27 TWD 20 TWD 22 TWD 24 TWD 21 TWD 21 TWD 21 TWD 21 TWD 21 TWD 24 TWD 32 TWD 28 TWD 22 TWD 27 TWD 30 TWD 20 TWD 22 TWD 26 TWD 32 TWD 21 TWD 21 TWD 20 TWD 26 TWD 24 TWD 25 TWD 29 TWD 37 TWD 26 TWD 29 TWD 23 TWD 22 TWD 25 TWD 20 TWD 21 TWD 30 TWD 27 TWD 22 TWD 27 TWD 21 TWD 29 TWD 33 TWD 32 TWD 35 TWD 27 TWD 22 TWD 21 TWD 29 TWD 27 TWD 20 TWD 27 TWD 27 TWD 24 LOCATION AV2

+0.31 AV3

+0.35 AV4

+0.35 AV5

+0.00 AV6

-0.18 AV7

+0.37 AV4

+0.00 AV5

+0.04 AV6

+0.02 AV2

+0.00 AV3

+0.00 AV5

+0.00 AV7

+0.00 AV7

+0.00 AV3

+0.00 AV2

+0.00 AV2

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV7

+0.00 AV7

+0.00 AV6

+0.00 AV3

+0.00 AV5

+0.00 AV3

+0.00 AV2

+0.00 AV5

+0.00 AV2

+0.00 AV8

+0.00 AV7

+0.00 AV7

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV3

+0.00 AV7

+0.00 AV4

+0.00 AV7

+0.00 AV5

+0.00 AV5

+0.00 AV7

+0.00 AV3

+0.00 AV4

+0.00 AV6

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV7

+0.00 AV5

-0.20 AV3

-0.13 AV2

+0.00 AV4

+0.00 AV5

+0.00 AV7

+0.00 AV8

+0.00 AV2

+0.00 AV7

+0.00 AV6

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV6

+0.00 AV7

+0.00 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL #

2 2

2 2

2 1

1 1

16 16 16 16 13 13 13 14 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 31 31 31 31 DWS 36 31 31 31 31 31 31 30 30 30 30 30 30 31 31 31 31 31 31 30 30 30 30 30 31 30 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UDL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL Total Tubes

599 Total Records: 1666

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:32 Component: S/G A Page 1 of 73 Component: S/C A Page 1 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 1 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS

=== --

=

25 166 0.27 27 4

0.11 27 164 0.12 31 164 0.12 31 166 0.16 0.26 32 163 0.13 33 6

0.18 0.15 33 8

0.16 33 164 0.20 0.29 34 5

0.12 34 163 0.18 0.12 34 165 0.18 35 162 0.15 35 164 0.23 36 7

0.15 0.13 36 161 0.13 36 165 0.11 37 8

0.15 37 10 0.10 37 162 0.11 0.14 0.13 37 164 0.13 38 5

0.12 38 7

0.27 38 9

0.12 0.13 38 161 0.13 38 163 0.21 0.23 38 165 0.12 0.23 39 6

0.33 0.13 39 162 0.28 39 164 0.31 0.22 40 7

0.22 0.19 40 9

0.21 40 163 0.14 41 8

0.16 41 162 0.31 41 164 0.13 0.13 42 7

0.20 42 9

0.16 42 161 0.12 0.25 0.45 42 163 0.30 0.17 0.11 43 6

0.11 0.13 0.12 43 8

0.14 0.12 0.14 43 154 0.24 0.11 43 160 0.13 43 162 0.21 0.13 43 164 0.13 0.16 0.16 44 7

0.14 0.27 0.26 0.16 44 141 0.14 44 159 0.11 44 161 0.30 DEG CHN 116 P2 71 P2 126 P2 81 P2 111 P2 114 P2 55 P2 131 P2 115 P2 122 P2 127 P2 103 P2 90 P2 113 P2 126 P2 116 P2 84 P2 91 P2 114 P2 117 P2 82 P2 143 P2 112 P2 113 P2 118 P2 116 P2 106 P2 104 P2 108 P2 110 P2 99 P2 96 P2 100 P2 139 P2 125 P2 66 P2 127 P2 121 P2 117 P2 117 P2 107 P2 119 P2 115 P2 112 P2 116 P2 74 P2 114 P2 117 P2 110 P2 124 P2 120 P2 119 P2 86 P2 115 P2 123 P2 106 P2 113 P2 85 P2 119 P2 107 P2 106 P2 83 P2 114 P2 130 P2 134 P2 143 P2 62 P2 116 P2 92 P2 126 P2 107 P2 117 P2 88 P2 125 P2 131 P2 119 P2 90 P2 115 P2 128 P2 IND %TW TWD 10 TWD 5 TWD 6 TWD 6 TWD 8 TWD 11 TWD 6 TWD 8 TWD 7 TWD 7 TWD 8 TWD 11 TWD 5 TWD 8 TWD 6 TWD 8 TWD 7 TWD 10 TWD 7 TWD 6 TWD 6 TWD 5 TWD 7 TWD 5 TWD 5 TWD 6 TWD 5 TWD 5 TWD 5 TWD 11 TWD 5 TWD 6 TWD 5 TWD 10 TWD 10 TWD 6 TWD 10 TWD 13 TWD 6 TWD 12 TWD 13 TWD 10 TWD 9 TWD 8 TWD 9 TWD 6 TWD 7 TWD 11 TWD 5 TWD 5 TWD 8 TWD 7 TWD 5 TWD 9 TWD 15 TWD 12 TWD 8 TWD 5 TWD 5 TWD 6 TWD 5 TWD 6 TWD 6 TWD 6 TWD 10 TWD 6 TWD 6 TWD 9 TWD 6 TWD 6 TWD 7 TWD 8 TWD 6 TWD 11 TWD 11 TWD 7 TWD 6 TWD 6 TWD 12 LOCATION AV7

+0.00 AV7

+0.31 AV7

-0.42 AV7

+0.20 AVI

-0.29 AV7

+0.18 AV7

-0.27 AV2

-0.15 AV7

+0.29 AV2

+0.24 AV7

+0.20 AV2

-0.24 AV7

+0.29 AV2

-0.27 AV7

+0.13 AV7

+0.16 AV2

+0.20 AV7

+0.18 AV2

-0.20 AV7

+0.29 AV7

+0.18 AV7

+0.00 AV7

+0.26 AV2

+0.31 AV2

-0.22 AV7

+0.20 AV7

-0.29 AV7

-0.33 AV7

+0.09 AV7

+0.00 AVl

+0.00 AV2

+0.00 AV7

-0.29 AV2

-0.24 AV7

+0.20 AVl

-0.31 AV7

+0.18 AV2

+0.00 AV7

+0.33 AV7

+0.16 AV2

+0.25 AV7

+0.20 AV2

-0.24 AV7

+0.26 AV7

-0.22 AVl

+0.09 AV2

-0.18 AV2

+0.20 AV7

-0.31 AV2

-0.24 AV7

+0.00 AV2

-0.20 AV8

-0.24 AV7

-0.27 AV6

+0.11 AV2

+0.20 AV7

-0.27 AV8

-0.25 AV2

+0.00 AV7

+0.00 AV8

+0.00 AVI

+0.22 AV6

+0.31 AV7

+0.26 AV3

-0.38 AV6

+0.27 AVI

+0.00 AV6

+0.38 AV7

+0.18 AV2

-0.31 AV6

+0.29 AV7

+0.20 AV2

-0.20 AV3

-0.20 AV6

+0.31 AV7

+0.26 AV6

-0.31 AV7

-0.29 AV6

+0.00 EXT EXT TEC TEH TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEC TEH TEC TEH TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEC TEH TEH TEC TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL #

2 52 1

11 1

2 53 53 52 2

2 52 1

1 1

1 53 53 1

2 52 52 2

2 2

2 52 52 52 52 2

1 1

1 1

52 52 11 1

53 53 53 2

52 2

2 2

52 52 2

2 2

1 1

1 52 52 52 53 53 53 1

1 1

1 1

1 1

1 53 53 53 53 5

1 1

LEG HOT COLD HOT HOT HOT HOT HOT COLD COLD COLD HOT HOT COLD HOT HOT HOT HOT HOT COLD COLD HOT HOT COLD COLD HOT HOT HOT HOT COLD COLD COLD COLD HOT HOT HOT HOT HOT COLD COLD HOT HOT HOT COLD COLD COLD HOT COLD HOT HOT HOT COLD COLD HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD HOT HOT HOT PROBE 610 DL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:32 Component: S/G A Page 2 of 73 Component: S/G A Page 2 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 2 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 44 163 0.13 0.56 0.14 0.14 0.11 45 8

0.14 0.12 45 12 0.13 45 142 0.17 45 154 0.16 0.30 45 158 0.13 0.16 45 160 0.12 0.13 45 162 0.26 0.20 0.11 46 7

0.20 0.27 0.16 46 9

0.15 46 11 0.15 0.13 0.16 46 13 0.13 46 141 0.11 46 159 0.13 46 161 0.12 0.44 0.23 46 163 0.14 0.21 0.31 0.13 47 8

0.17 0.17 0.21 47 44 0.16 47 142 0.17 47 154 0.14 47 160 0.18 0.30 0.17 0.16 0.21 47 162 0.22 0.21 0.13 48 7

0.20 0.11 0.15 48 9

0.21 0.26 0.24 0.15 48 11 0.12 48 13 0.12 48 35 0.16 48 141 0.12 48 153 0.12 48 159 0.13 48 161 0.14 0.34 0.33 48 163 0.17 49 8

0.16 49 10 0.20 0.14 0.25 49 12 0.11

0. 12 49 16 0.14 49 34 0.12 49 108 0.10 49 128 0.11 49 142 0.12 49 144 0.12 49 154 0.19 49 160 0.19 DEG CHN 117 P2 112 P2 140 P2 94 P2 50 P2 117 P2 88 P2 84 P2 113 P2 124 P2 124 P2 90 P2 127 P2 128 P2 126 P2 124 P2 108 P2 61 P2 130 P2 120 P2 99 P2 121 P2 112 P2 127 P2 140 P2 143 P2 124 P2 76 P2 109 P2 120 P2 129 P2 99 P2 109 P2 108 P2 92 P2 131 P2 107 P2 112 P2 137 P2 93 P2 125 P2 95 P2 114 P2 133 P2 108 P2 115 P2 127 P2 128 P2 47 P2 136 P2 97 P2 92 P2 108 P2 119 P2 129 P2 116 P2 107 P2 112 P2 126 P2 101 P2 85 P2 100 P2 66 P2 113 P2 105 P2 110 P2 105 P2 114 P2 130 P2 133 P2 121 P2 86 P2 117 P2 119 P2 95 P2 31 P2 143 P2 132 P2 131 P2 123 P2 IND %TW TWD 5 TWD 17 TWD 6 TWD 6 TWD 5 TWD 6 TWD 5 TWD 6 TWD 7 TWD 6 TWD 11 TWD 6 TWD 6 TWD 5 TWD 5 TWD 10 TWD 8 TWD 5 TWD 8 TWD 11 TWD 7 TWD 6 TWD 7 TWD 6 TWD 7 TWD 6 TWD 5 TWD 5 TWD 5 TWD 15 TWD 9 TWD 7 TWD 9 TWD 13 TWD 6 TWD 7 TWD 8 TWD 9 TWD 6 TWD 7 TWD 7 TWD 8 TWD 12 TWD 8 TWD 7 TWD 9 TWD 10 TWD 9 TWD 6 TWD 9 TWD 5 TWD 7 TWD 9 TWD 11 TWD 10 TWD 7 TWD 5 TWD 6 TWD 6 TWD 6 TWD 5 TWD 6 TWD 7 TWD 14 TWD 13 TWD 7 TWD 7 TWD 8 TWD 6 TWD 10 TWD 5 TWD 5 TWD 6 TWD 4 TWD 5 TWD 7 TWD 5 TWD 5 TWD 8 TWD 8 LOCATION AV8

-0.22 AV7

-0.31 AV6

+0.22 AV2

+0.24 AVI

-0.31 AV6

+0.26 AV7

+0.26 AV2

+0.00 AV6

+0.20 AV6

+0.18 AV3

-0.29 AV8

+0.11 AV6

+0.15 AV7

+0.11 AV2

-0.27 AV6

+0.22 AV2

-0.20 AVl

-0.20 AV3

+0.00 AV6

+0.00 AV7

+0.00 AV6

+0.00 AV2

+0.00 AV3

+0.00 AV6

+0.00 AV2

+0.00 AV6

-0.35 AV7

+0.15 AV7

+0.13 AV6

+0.15 AV2

-0.18 AV2

-0.27 AV6

+0.20 AV7

+0.22 AV8

+0.16 AV3

-0.13 AV6

+0.29 AV7

+0.26 AV3

-0.13 AV6

+0.13 AV6

+0.20 AVI

+0.16 AV2

-0.22 AV6

+0.16 AV7

+0.16 AV8

+0.00 AV2

-0.22 AV3

-0.18 AV8

-0.27 AV3

-0.13 AV6

+0.24 AV7

+0.26 AV2

-0.18 AV3

-0.15 AV6

+0.24 AV7

+0.26 AV2

-0.15 AV3

-0.11 AV3

+0.26 AV6

-0.26 AV6

-0.35 AV7

+0.16 AVI

+0.13 AV2

-0.22 AV7

+0.16 AV7

-0.31 AV3

+0.00 AV2

-0.18 AV3

+0.00 AV7

+0.07 AV2

-0.15 AV3

-0.15 AV3

+0.00 AV3

+0.00 AV6

+0.09 AV3

+0.00 AV6

+0.15 AV3

+0.07 AV3

-0.26 AV7

+0.09 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL #

2 2

2 2

2 52 52 52 6

2 2

2 2

2 2

2 2

2 52 52 52 52 52 52 52 52 6

2 2

21 1

1 1

53 53 53 19 5

1 1

1 1

1 1

1 1

1 53 53 53 53 53 53 53 53 53 24 5

3 1

1 1

1 2

52 52 52 52 53 53 52 23 29 23 6

6 22 LEG HOT HOT HOT HOT HOT COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT PROBE 610TUL 61OUL 61OUL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610OL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610OL 610UL 610UL 610UL 610UL 610UL 610UL 610TDL 610OL 610UL 610UL 610UL 610OL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610DL 610UL 610UL 610UL 610UL 610OL 610UL 610UL 610OL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:32 Component: S/G A Page 3 of 73 Component: S/C A Page 3 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: Querytl, Enc. 2 Page 3 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.22 49 162 0.15 0.31 0.12 0.25 50 7

0.12 0.16 0.19 50 9

0.25 0.31 0.16 0.11 50 11 0.48 0.17 0.23, 50 11 0.11 50 147 0.14 50 153 0.14 0.27 50 155 0.13 50 157 0.12 50 159 0.18 0.12 0.18 50 161 0.20 0.29 0.14 50 163 0.10 0.13 0.32 51 8

0.21 0.20 51 10 0.19 51 18 0.11 51 34 0.12 51 102 0.12 51 108 0.12 51 124 0.10 51 144 0.23 51 154 0.48 0.28 0.11 51 156 0.28 0.25 51 158 0.15 0.12 51 160 0.18 0.53 0.21 0.30 0.21 51 162 0.30 0.51 0.41 0.26 52 9

0.17 0.44 0.26 0.19 52 11 0.20 0.23 0.26 0.11 52 13 0.20 52 17 0.12 0.11 0.12 52 35 0.26 0.10 52 121 0.15 52 141 0.22 52 149 0.14 52 153 0.12 0.14 52 155 0.12 52 159 0.16 0.28 0.17 52 161 0.14 0.31 DEG CHN 119 P2 120 P2 120 P2 129 P2 128 P2 112 P2 121 P2 123 P2 130 P2 119 P2 138 P2 85 P2 119 P2 93 P2 94 P2 77 P2 123 P2 88 P2 124 P2 80 P2 123 P2 95 P2 120 P2 130 P2 120 P2 120 P2 111 P2 128 P2 119 P2 103 P2 109 P2 120 P2 91 P2 144 P2 126 P2 122 P2 135 P2 147 P2 110 P2 107 P2 123 P2 88 P2 109 P2 75 P2 117 P2 83 P2 76 P2 112 P2 125 P2 110 P2 87 P2 107 P2 112 P2 118 P2 114 P2 119 P2 123 P2 110 P2 95 P2 125 P2 128 P2 109 P2 79 P2 116 P2 127 P2 144 P2 128 P2 126 P2 128 P2 133 P2 103 P2 119 P2 57 P2 88 P2 134 P2 117 P2 118 P2 106 P2 54 P2 123 P2 IND %TW LOCATION TWD 9 AV2

-0.22 TWD 6 AV7

+0.20 TWD 11 AV6

+0.15 TWD 5 AV3

-0.22 TWD 9 AV2

-0.20 TWD 5 AV3

-0.15 TWD 7 AV6

+0.00 TWD 8 AV7

+0.29 TWD 10 AV3

+0.00 TWD 12 AV6

+0.00 TWD 7 AV7

+0.24 TWD 5 AV2

-0.24 TWD 16 AV2

+0.00 TWD 7 AV6

+0.00 TWD 9 AV7

+0.00 TWD 5 AV6

-0.28 TWD 6 AV6

+0.13 TWD 6 AV6

-0.40 TWD 10 AV3

+0.24 TWD 6 AV6

-0.31 TWD 6 AV6

+0.13 TWD 7 AV7

+0.13 TWD 5 AV6

+0.15 TWD 7 AV2

-0.15 TWD 8 AV7

+0.13 TWD 11 AV6

+0.20 TWD 6 AV2

-0.27 TWD 5 AV3

-0.22 TWD 6 AV6

+0.18 TWD 13 AV7

-0.25 TWD 9 AV3

-0.20 TWD 9 AV6

+0.29 TWD 8 AV2

-0.13 TWD 5 AV3

-0.13 TWD 5 AV3

-0.15 TWD 6 AV6

+0.00 TWD 6 AV6

+0.13 TWD 5 AV6

+0.15 TWD 10 AV3

+0.13 TWD 17 AV3

-0.27 TWD 12 AV6

+0.16 TWD 6 AV7

+0.11 TWD 12 AV6

+0.18 TWD 11 AV7

+0.16 TWD 7 AV7

+0.11 TWD 6 AV8

-0.22 TWD 8 AVI

+0.18 TWD 19 AV2

-0.22 TWD 9 AV3

+0.00 TWD 12 AV7

+0.16 TWD 9 AV8

-0.24 TWD 12 AVi

-0.24 TWD 18 AV2

-0.24 TWD 16 AV3

-0.20 TWD 11 AV7

+0.16 TWD 8 AV2

-0.13 TWD 16 AV3

-0.15 TWD 11 AV6

+0.24 TWD 8 AV7

+0.26 TWD 9 AV2

-0.15 TWD 10 AV6

+0.24 TWD 11 AV7

+0.22 TWD 5 AV8

-0.11 TWD 9 AV2

-0.11 TWD 5 AV2

-0.15 TWD 5 AV3

-0.09 TWD 5 AV6

+0.26 TWD 9 AV3

+0.22 TWD 4 AV6

+0.15 TWD 6 AV3

+0.15 TWD 9 AV6

-0.33 TWD 6 AV6

+0.24 TWD 6 AV3

+0.22 TWD 7 AV6

-0.35 TWD 5 AV6

+0.20 TWD 7 AVI

-0.22 TWD 12 AV2

-0.24 TWD 8 AV7

+0.16 TWD 7 AVI

-0.24 TWD 13 AV2

-0.22 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL 2

2 2

2 2

52 52 52 52 52 52 52 52 52 52 29 5

4 4

1 1

2 2

2 2

2 2

1 1

1 53 53 53 55 24 19 29 26 51 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

53 53 53 53 53 53 53 53 53 55 55 55 24 24 26 5

4 3

3 2

1 1

1 1

1

  1. LEG HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:32 Component: S/G A Page 4 of 73 Component: S/C A Page 4 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 4 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.47 0.15 53 8

0.39 0.31 0.15 53 10 0.15 0.24 0.12 0.18 53 12 0.13 53 20 0.12 53 34 0.19 0.20 53 44 0.10 0.09 53 54 0.09 53 102 0.11 53 124 0.13 53 128 0.18 53 130 0.12 53 136 0.10 53 142 0.24 53 144 0.10 53 154 0.25 0.34 53 156 0.38 0.25 53 158 0.25 53 160 0.26 0.15 0.30 0.11 53 162 0.20 0.13 54 9

0.48 54 11 0.24 0.30 54 13 0.16 54 15 0.17 54 19 0.13 54 101 0.18 54 109 0.19 54 119 0.10 54 121 0.10 54 139 0.13 54 141 0.10 54 143 0.11 54 147 0.21 54 153 0.12 54 155 0.13 0.15 54 157 0.14 0.26 54 159 0.21 0.11 0.12 0.21 55 10 0.31 0.18 0.16 0.16 55 12 0.13 0.15 55 14 0.13 0.13 55 16 0.13 55 26 0.13 55 34 0.13 0.15 55 108 0.13 55 112 0.15 55 116 0.11i 55 120 0.18 55 122 0.13 55 124 0.10 55 128 0.12 55 134 0.14 55 142 0.27 55 144 0.20 55 148 0.12 DEG 124 85 107 121 96 72 123 121 110 120 107 119 119 136 99 152 115 92 86 96 103 121 134 123 ill 109 130 108 116 77 108 102 125 102 107 138 128 97 123 125 109 86 118 82 77 83 131 116 88 74 94 140 115 126 126 115 129 115 ill 97 113 119 125 122 138 107 120 129 137 88 85 140 103 122 156 145 124 99 ill 110 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW LOCATION TWD 17 AV6

+0.00 TWD 7 AV7

+0.00 TWD 14 AV2

+0.00 TWD 12 AV3

+0.00 TWD 6 AV8

+0.29 TWD 6 AVI

+0.00 TWD 10 AV2

+0.00 TWD 5 AV6

+0.00 TWD 8 AV7

+0.00 TWD 6 AV3

-0.15 TWD 5 AV3

-0.18 TWD 6 AV3

+0.00 TWD 7 AV6

+0.00 TWD 4 AV2

+0.02 TWD 4 AV3

-0.24 TWD 3 AV3

-0.11 TWD 5 AV6

+0.00 TWD 7 AV3

+0.00 TWD 10 AV3

+0.00 TWD 7 AV6

+0.09 TWD 5 AV6

-0.04 TWD 10 AV6

+0.15 TWD 4 AV3

+0.26 TWD 10 AV6

+0.13 TWD 12 AV3

-0.29 TWD 13 AV7

+0.13 TWD 10 AV6

+0.18 TWD 10 AV7

+0.13 TWD 11 AV2

-0.18 TWD 7 AV3

-0.24 TWD 12 AV7

+0.16 TWD 5 AV8

-0.27 TWD 9 AV3

-0.20 TWD 6 AV7

+0.00 TWD 16 AV6

+0.24 TWD 10 AV6

+0.00 TWD 11 AV7

+0.00 TWD 7 AV6

+0.00 TWD 7 AV3

+0.00 TWD 5 AV3

-0.15 TWD 9 AV6

+0.00 TWD 9 AV3

+0.00 TWD 6 AV6

+0.11 TWD 6 AV3

+0.00 TWD 7 AV6

-0.04 TWD 5 AV6

-0.31 TWD 5 AV6

+0.15 TWD 9 AV6

+0.11 TWD 5 AV3

+0.20 TWD 6 AVI

+0.13 TWD 7 AV6

+0.16 TWD 7 AV3

-0.20 TWD 11 AV6

+0.18 TWD 8 AV7

+0.00 TWD 5 AV6

+0.00 TWD 5 AV3

+0.00 TWD 8 AV2

+0.00 TWD 12 AV2

-0.13 TWD 8 AV3

-0.18 TWD 7 AV6

+0.24 TWD 7 AV7

+0.20 TWD 6 AV2

+0.00 TWD 6 AV6

+0.00 TWD 6 AV3

+0.13 TWD 6 AV6

+0.00 TWD 6 AV2

+0.00 TWD 5 AV3

-0.15 TWD 5 AV3

-0.13 TWD 6 AV6

+0.24 TWD 6 AV6

+0.18 TWD 7 AV6

+0.00 TWD 5 AV6

+0.15 TWD 8 AV3

-0.31 TWD 6 AV6

-0.22 TWD 5 AV3

+0.00 TWD 5 AV3

+0.00 TWD 6 AV6

+0.22 TWD 11 AV6

+0.16 TWD 9

  • AV3

+0.11 TWD 6 AV6

+0.11 EXT EXT TEC TEN TEC TEH TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEE TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEE TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEE TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL #

1 1

52 52 52 52 52 52 52 53 54 23 23 20 20 17 20 25 21 21 19 6

6 2

2 2

2 2

1 1

1 1

1 1

52 52 52 52 52 54 19 29 25 25 19 6

5 3

4 1

1 1

1 2

2 2

2 53 53 53 53 52 52 53 53 53 26 24 24 29 29 28 26 26 26 22 22 5

5 3

LEG HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610TUL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 61OUL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 61OUL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 6100L 61OUL 61OUL 610UL 61OUL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:32 Component:

S/G A Page 5 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 5 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 55 154 0.13 0.35 0.17 55 156 0.24 0.27 55 158 0.15 0.21 0.41 55 160 0.15 0.18 0.20 0.21 0.12 56 9

0.20 0.34 56 11 0.13 0.24 0.19 0.25 0.16 56 25 0.13 56 35 0.23 56 43 0.14 0.14 56 65 0.10 56 107 0.14 56 111 0.16 56 121 0.13 0.21 0.12 56 123 0.14 0.15 56 125 0.10 56 127 0.15 56 147 0.23 56 153 0.26 0.17 56 155 0.11 56 159 0.26 0.40 0.31 56 161 0.15 0.44 0.15 57 10 0.23 0.16 0.22 0.16 57 14 0.14 0.17 0.17 0.15 57 18 0.11 57 20 0.23 57 22 0.14 57 28 0.13 57 44 0.08 57 100 0.15 57 102 0.18 57 104 0.14 57 108 0.14 57 116 0.34 57 120 0.20 57 124 0.10 57 126 0.11 0.15 57 128 0.10 0.10 57 138 0.13 57 142 0.23 57 148 0.19 57 154 0.18 0.36 0.14 57 156 0.25 0.13 0.20 57 158 0.37 0.33 0.34 DEG 53 116 123 91 106 109 125 114 76 106 117 124 126 127 130 86 118 107 113 101 128 131 120 150 140 97 95 143 136 133 151 134 146 151 110 94 101 125 102 109 113 107 123 95 98 126 117 136 141 135 145 141 85 119 133 132 33 122 102 62 113 107 86 65 149 146 92 77 94 120 129 129 124 99 112 103 125 121 127 123 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWO TWD

%TW LOCATION 6

AVI 14 AV3 8

AV6 10 AVl 11 AV7 7

AV3 9

AV6 15 AV7 6

AV2 7

AVI 8

AV7 8

AV3 5

AV3 9

AV3 13 AV6 6

AVI 10 AV2 8

AV6 10 AV7 7

AV8 5

AV3 8

AV3 5

AV3 5

AV6 4

AV6 6

AV3 7

AV6 6

AV7 9

AV6 5

AV3 6

AV6 6

AV3 5

AV2 6

AV6 9

AV6 11 AV3 8

AV6 5

AV8 11 AVI 15 AV2 13 AV7 6

AV7 15 AV6 6

AV2 9

AV2 7

AV3 9

AV6 7

AV7 6

AVI 7

AV2 7

AV3 6

AV6 5

AV2 9

AV3 6

AV3 4

AV3 3

AV3 6

AV6 7

AV6 6

AV6 6

AV6 14 AV6 10 AV3 6

AV6 5

AV7 6

AV6 6

AV6 6

AV3 7

"AV6 9

AV6 8

AV6 7

AV6 13 AV3 6

AVI 9

AV7 5

AV6 8

AVI 14 AV2 13 AV3 14 AV6

+0.13

-0.27

+0.11

+0.00

+0.22

+0.00

+0.00

+0.13

+0.00

+0.00

+0.00

+0.26

-0.21

-0.18

+0.24

-0.11

-0.13

+0.24

+0.22

+0.22

+0.00

+0.26

-0.20

-0.13

+0.11

-0.04

+0.00

+0.00

+0.00

+0.11

+0.00

+0.00

+0.00

+0.00

-0.37

+0.15

+0.00

-0.15

-0.29

-0.20

+0.16

+0.00

+0.16

+0.00

-0.13

+0.00

+0.26

+0.00

+0.00

+0.00

+0.00

+0.00

-0.15

-0.15

-0.13

+0.00

-0.18

+0.00

+0.00

+0.00

+0.09

+0.00

-0.29

+0.00

+0.00

+0.00

+0.00

-0.24

+0.00

+0.13

-0.07

+0.09

-0.24

-0.24

+0.15

+0.15

+0.13

+0.00

+0.00

+0.00 EXT TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC EXT TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH UTIL 1

UTIL 2

CAL #

1 1

1 1

1 1

1 1

2 2

2 2

2 53 53 53 53 53 53 53 54 24 20 20 15 30 29 26 26 26 26 26 26 24 4

3 3

2 1

1 1

2 2

2 52 52 52 52 52 52 52 52 54 54 54 25 20 20 20 30 29 27 25 25 24 24 21 21 19 6

4 2

2 2

2 2

2 1

1 1

LEG PROBE HOT 610UL HOT 610UL HOT 61OUL HOT 610UL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 610UL HOT 61OUL HOT 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL HOT 61OUL HOT 61OUL HOT 610UL HOT 610UL HOT 61OUL HOT 610UL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 610UL HOT 610UL HOT 610UL HOT 610UL HOT 610UL HOT 610UL HOT 610UL COLD 610UL COLD 610UL COLD 610UL COLD 61OUL COLD 610UL COLD 610UL COLD 61OUL COLD 61OUL COLD 610UL COLD 610UL COLD 610UL COLD 61OUL COLD 610UL HOT 610UL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 610UL HOT 61OUL HOT 610UL HOT 61OUL HOT 610UL HOT 610UL HOT 610UL HOT 610UL HOT 610UL HOT 610UL HOT 610UL HOT 610UL HOT 610UL HOT 610UL HOT 610UL HOT 610UL HOT 610UL HOT 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:32 Component: S/G A Page 6 of 73 Component: S/C A Page 6 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 6 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.25 57 160 0.14 0.19 0.18 0.27 58 9

0.22 0.14 0.16 58 11 0.19 0.35 0.32 0.23 0.22 58 13 0.13 58 17 0.23 0.12 58 35 0.17 0.17 58 43 0.12 58 101 0.10 58 113 0.13 0.16 58 115 0.10 58 125 0.12 58 127 0.10 58 133 0.12 58 141 0.15 58 153 0.15 58 155 0.16 0.10 0.26 0.16 58 157 0.13 58 159 0.15 0.21 0.18 58 161 0.14 0.15 0.24 0.13 59 10 0.13 0.23 0.35 0.19 0.12 0.13 59 12 0.23 0.15 0.24 0.20 0.16 59 14 0.13 0.15 59 18 0.12 59 20 0.20 59 34 0.13 59 44 0.12 59 58 0.12 59 76 0.13 59 84 0.12 0.11 59 100 0.12 59 102 0.21 0.15 59 104 0.14 59 106 0.13 59 108 0.14 0.19 0.11 59 110 0.21 0.16 0.14 59 116 0.13 59 120 0.17 59 124 0.11 59 128 0.10 59 132 0.09 59 142 0.16 59 148 0.19 59 154 0.16 DEG 121 120 102 117 95 125 90 92 124 116 123 125 69 138 125 113 109 112 129 83 122 139 149 62 130 47 80 122 85 136 129 106 88 123 109 115 133 132 118 125 90 113 122 119 113 101 136 109 114 82 95 108 100 127 127 112 ill 131 56 146 104 97 103 95 135 149 76 108 113 ill 107 99 117 98 141 142 85 105 119 105 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW LOCATION TWD 11 AV7

+0.18 TWD 7 AVI

-0.26 TWD 8 AV2

-0.24 TWD 8 AV6

+0.00 TWD 11 AV7

+0.19 TWD 9 AV3

-0.15 TWD 6 AV7

-0.18 TWD 7 AV8

+0.31 TWD 8 AVI

+0.00 TWD 13 AV2

+0.00 TWD 12 AV6

+0.00 TWD 9 AV7

+0.00 TWD 9 AV8

+0.00 TWD 6 AVI

+0.00 TWD 9 AV3

-0.13 TWD 5 AV8

-0.11 TWD 6 AV3

+0.00 TWD 6 AV6

+0.00 TWD 5 AV6

-0.07 TWD 5 AV6

+0.00 TWD 6 AV7

+0.00 TWD 7 AV2

+0.00 TWD 4 AV3

+0.00 TWD 7 AV2

+0.02 TWD 7 AV6

+0.04 TWD 7 AV6

+0.00 TWD 6 AV7

+0.15 TWD 6 AV6

+0.20 TWD 7 AVI

-0.24 TWD 5 AV2

-0.20 TWD 11 AV6

+0.00 TWD 8 AV8

-0.27 TWD 6 AV6

+0.16 TWD 6 AV6

+0.00 TWD 8 AV3

+0.00 TWD 7 AVI

+0.00 TWD 7 AV3

-0.21 TWD 7 AV6

-0.07 TWD 11 AV7

-0.23 TWD 6 AV6

-0.33 TWD 6 AVI

-0.15 TWD 10 AV2

-0.15 TWD 13 AV3

-0.11 TWD 8 AV6

+0.24 TWD 5 AV7

+0.24 TWD 6 AV8

+0.26 TWD 9 AVI

+0.00 TWD 7 AV2

+0.00 TWD 10 AV3

+0.00 TWD 8 AV7

+0.00 TWD 7 AV8

+0.00 TWD 6 AV6

+0.26 TWD 7 AV8

+0.00 TWD 5 AV3

-0.18 TWD 8 AV3

-0.15 TWD 5 AV6

+0.28 TWD 5 AV3

-0.22 TWD 5 AV6

-0.13 TWD 5 AV6

+0.00 TWD 5 AV6

+0.00 TWD 5 AV7

+0.26 TWD 6 AV6

+0.26 TWD 10 AV6

+0.00 TWD 7 AV3

+0.00 TWD 6 AV6

+0.00 TWD 6 AV6

+0.00 TWD 6 AV6

+0.15 TWD 9 AV3

+0.00 TWD 5 AV2

+0.00 TWD 9 AV6

+0.00 TWD 7 AV3

+0.00 TWD 7 AV2

+0.00 TWD 5 AV6

+0.00 TWD 7 AV3

-0.26 TWD 5 AV6

+0.13 TWD 4 AV6

+0.00 TWD 6 AV7

+0.00 TWD 7 AV6

+0.20 TWD 8 AV6

-0.07 TWD 8 AVI

+0.00 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL # LEG 1

NOT 1

HOT 1

HOT 1

HOT 1

HOT 52 COLD 52 COLD 52 COLD 52 COLD 52 COLD 52 COLD 52 COLD 52 COLD 52 COLD 54 COLD 54 COLD 23 COLD 23 COLD 19 COLD 19 HOT 27 HOT 27 HOT 28 HOT 25 HOT 23 HOT 21 HOT 6

HOT 4

HOT 1

HOT 1

HOT 1

HOT 1

HOT 1

HOT 2

HOT 2

HOT 2

HOT 1

HOT 1

HOT 1

HOT 1

HOT 53 COLD 53 COLD 53 COLD 53 COLD 53 COLD 53 COLD 52 COLD 52 COLD 52 COLD 52 COLD 52 COLD 53 COLD 53 COLD 55 COLD 55 COLD 24 COLD 19 COLD 18 COLD 14 COLD 12 COLD 12 COLD 19 HOT 19 HOT 19 HOT 31 HOT 31 HOT 29 HOT 29 HOT 29 HOT 29 HOT 29 HOT 29 HOT 28 HOT 26 HOT 26 HOT 22 HOT 21 HOT 5

HOT 3

HOT 1

NOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TCL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 61OUL 610UL 61OUL 61OUL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:32 Component: S/G A Page 7 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 7 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.24 0.15 59 156 0.15 0.25 0.29 0.13 59 160 0.11 0.27 0.09 60 11 0.20 0.26 0.21 60 13 0.16 0.17 60 15 0.19 60 17 0.12 0.13 60 53 0.11 60 61 0.08 0.22 60 67 0.17 0.09 60 103 0.13 60 109 0.15 0.23 60 121 0.11 60 123 0.13 60 141 0.13 60 147 0.11 60 153 0.21 0.27 60 155 0.12 60 157 0.11 0.60 0.25 0.24 60 159 0.41 0.16 0.25 0.29 0.26 0.16 61 10 0.26 0.37 0.10 0.18 61 12 0.16 61 14 0.15 0.14 0.17 0.21 0.17 61 16 0.16 61 22 0.26 61 34 0.20 0.15 61 44 0.12 61 50 0.18 61 66 0.13 61 102 0.45 0.18 61 104 0.18 0.13 0.16 61 106 0.22 61 108 0.18 0.17 0.14 61 110 0.16 0.15 61 112 0.12 0.25 61 114 0.16 0.19 0.16 61 116 0.52 0.30 0.17 61 126 0.13 61 130 0.13 DEG CHN 109 P2 107 P2 69 P2 122 P2 97 P2 66 P2 127 P2 125 P2 72 P2 103 P2 122 P2 126 P2 95 P2 111 P2 91 P2 96 P2 99 P2 141 P2 126 P2 134 P2 133 P2 136 P2 60 P2 104 P2 89 P2 151 P2 150 P2 86 P2 116 P2 89 P2 97 P2 113 P2 83 P2 125 P2 130 P2 126 P2 115 P2 111 P2 122 P2 126 P2 95 P2 78 P2 112 P2 129 P2 144 P2 131 P2 120 P2 99 P2 113 P2 136 P2 144 P2 135 P2 136 P2 121 P2 120 P2 119 P2 130 P2 134 P2 133 P2 121 P2 123 P2 72 P2 48 P2 84 P2 120 P2 109 P2 107 P2 123 P2 113 P2 105 P2 125 P2 118 P2 123 P2 110 P2 121 P2 118 P2 118 P2 106 P2 139 P2 92 P2 IND %TW TWD 11 TWD 7 TWD 7 TWD 11 TWD 12 TWD 6 TWD 5 TWD 10 TWD 4 TWD 9 TWD 11 TWD 9 TWD 7 TWD 8 TWD 8 TWD 5 TWD 5 TWD 4 TWD 3 TWD 8 TWD 6 TWD 3 TWO 5 TWD 7 TWD 10 TWD 5 TWD 6 TWD 6 TWD 5 TWD 9 TWD 11 TWD 5 TWD 5 TWD 18 TWD 9 TWD 9 TWD 16 TWD 8 TWD 11 TWD 12 TWD 11 TWD 7 TWD 10 TWD 14 TWD 5 TWD 8 TWD 7 TWD 6 TWD 6 TWD 7 TWD 9 TWD 7 TWD 7 TWD 10 TWD 7 TWD 5 TWD 5 TWD 7 TWD 5 TWD 15 TWD 7 TWD 7 TWD 5 TWD 6 TWD 8 TWD 8 TWD 8 TWD 6 TWD 7 TWO 7 TWD 6 TWD 11 TWD 8 TWD 9 TWD 8 TWD 19 TWD 13 TWD 8 TWD 5 TWD 8 LOCATION AV3

-0.22 AV6

+0.16 AVI

+0.00 AV6

+0.20 AV7

+0.20 AV8

+0.00 AV7

+0.00 AV2

+0.00 AV8

+0.14 AV2

-0.24 AV6

+0.24 AV7

+0.26 AV2

-0.13 AV6

+0.02 AV6

-0.18 AV2

-0.76 AV8

-0.17 AV6

+0.13 AV3

-0.07 AV6

+0.09 AV3

+0.00 AV6

-0.02 AV3

-0.09 AV6

+0.00 AV3

+0.00 AV3

+0.15 AV6

+0.00 AV6

-0.27 AV6

+0.00 AV3

+0.15 AV6

-0.27 AVi

-0.22 AV8

-0.13 AV7

+0.02 AV6

-0.02 AV3

-0.22 AVI

-0.22 AV2

-0.22 AV3

+0.00 AV6

+0.00 AV7

+0.00 AV8

+0.00 AV3

-0.09 AV6

+0.24 AV7

+0.24 AV8

+0.22 AV3

+0.29 AV2

+0.00 AV3

+0.00 AV6

+0.00 AV7

+0.00 AV8

+0.00 AV3

+0.00 AV3

-0.11 AV3

+0.00 AV6

+0.00 AV3

-0.20 AV3

+0.02 AV3

+0.00 AV6

+0.00 AV3

+0.00 AV6

+0.00 AV3

+0.00 AV2

+0.00 AV6

+0.00 AV6

+0.00 AV3

+0.00 AV2

+0.00 AV6

+0.00 AV3

+0.00 AV6

+0.15 AV3

-0.13 AV6

+0.18 AV3

+0.00 AV2

+0.00 AV6

+0.00 AV3

+0.00 AV2

+0.00 AV3

+0.00 AV6

+0.00 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL #

1 1

1 1

1 1

22 2

53 53 53 53 53 53 55 55 17 15 15 15 15 30 29 29 26 26 5

4 3

3 2

2 2

2 2

1 1

1 1

1 1

52 52 52 52 53 52 52 52 52 52 52 54 23 23 20 19 15 20 20 30 30 30 30 29 29 29 29 29 27 27 27 27 27 27 27 27 24 21 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 61OUL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610OL 610UL 610UL 610UL 610UL 610UL 610UL 610OL 61OUL 610UL 610UL 610OL 610UL 610UL 610UL 610DL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610DL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 61OUL 610OL 61OUL 61OUL 61OUL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:32 Component: S/G A Page 8 of 73 Component: S/C A Page 8 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page8of73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 61 134 0.11 61 140 0.16 0.12 61 142 0.29 61 154 0.12 61 156 0.17 0.29 0.37 0.13 61 158 0.25 0.25 0.18 0.43 61 160 0.25 0.20 62 11 0.22 0.30 0.26 0.15 0.29 0.25 62 13 0.29 0.25 0.15 62 15 0.27 62 17 0.15 62 65 0.17 62 73 0.16 62 97 0.11 62 103 0.09 0.11 62 105 0.33 62 107 0.16 0.38 62 109 0.30 0.21 62 111 0.23 62 113 0.18 0.14 0.13 62 117 0.13 62 121 0.27 62 139 0.11 62 153 0.24 0.33 62 157 0.22 0.21 0.28 0.40 62 159 0.20 0.25 0.24 63 12 0.19 0.23 0.28 63 14 0.14 0.12 63 16 0.14 0.33 0.17 63 18 0.16 63 34 0.17 63 36 0.11 63 44 0.15 63 58 0.13 0.24 63 60 0.13 0.15 63 64 0.17 0.25 63 76 0.19 0.15 63 78 0.21 63 98 0.10 0.17 63 100 0.24 63 102 0.20 63 104 0.13 0.17 0.11 DEG CHN 50 P2 128 P2 153 P2 119 P2 95 P2 95 P2 117 P2 118 P2 92 P2 123 P2 107 P2 109 P2 107 P2 130 P2 107 P2 116 P2 103 P2 107 P2 119 P2 105 P2 103 P2 134 P2 127 P2 135 P2 132 P2 127 P2 105 P2 133 P2 63 P2 114 P2 123 P2 134 P2 125 P2 129 P2 95 P2 79 P2 96 P2 98 P2 90 P2 135 P2 132 P2 104 P2 60 P2 112 P2 129 P2 116 P2 78 P2 101 P2 96 P2 121 P2 118 P2 97 P2 121 P2 124 P2 108 P2 111 P2 92 P2 104 P2 132 P2 134 P2 79 P2 143 P2 117 P2 115 P2 134 P2 107 P2 140 P2 104 P2 133 P2 125 P2 115 P2 141 P2 119 P2 72 P2 109 P2 108 P2 125 P2 142 P2 150 P2 141 P2 IND %TW LOCATION TWD 7 AV6

+0.00 TWD 6 AV6

+0.11 TWD 5 AV2

+0.00 TWD 11 AV6

-0.04 TWD 5 AV6

-0.20 TWD 7 AV8

-0.18 TWD 11 AV7

+0.15 TWD 13 AV6

+0.13 TWD 5 AVI

-0.22 TWD 11 AV2

-0.13 TWD 11 AV3

+0.20 TWD 8 AV6

+0.00 TWD 16 AV7

+0.18 TWD 11 AV3

-0.26 TWD 9 AV7

-0.26 TWD 9 AVI

+0.00 TWO 12 AV2

+0.00 TWD 10 AV3

+0.00 TWD 6 AV8

+0.00 TWD 11 AV6

-0.18 TWD 10 AV6

+0.24 TWD 11 AV3

+0.00 TWD 10 AV6

+0.00 TWO 6 AV7

+0.00 TWD 11 AV6

+0.00 TWD 6 AV3

-0.13 TWD 7 AV6

+0.00 TWO 6 AV6

+0.00 TWD 6 AV6

-0.33 TWD 4 AV3

+0.00 TWD 5 AV6

+0.00 TWD 12 AV6

+0.00 TWD 6 AV3

+0.00 TWD 13 AV6

+0.00 TWD 12 AV3

+0.00 TWD 9 AV2

+0.00 TWD 10 AV6

+0.00 TWD 9 AV7

+0.00 TWO 7 AV6

+0.00 TWD 6 AV3

+0.00 TWD 5 AV3

+0.00 TWD 13 AV6

+0.00 TWD 6 AV2

-0.18 TWD 9 AV6

+0.15 TWD 12 AV3

-0.11 TWD 10 AVl

+0.00 TWD 9 AV3

+0.00 TWD 12 AV7

+0.16 TWD 15 AV8

+0.18 TWD 8 AV8

+0.00 TWD 10 AV2

+0.00 TWD 9 AVI

+0.00 TWO 8 AVl

+0.00 TWD 9 AV2

+0.00 TWD 11 AV3

+0.00 TWD 6 AV3

-0.15 TWD 5 AV6

-0.18 TWD 6 AV2

+0.00 TWD 13 AV3

+0.00 TWD 8 AV8

+0.00 TWD 6 AV3

+0.28 TWD 6 AV6

+0.22 TWD 5 AV3

+0.26 TWD 5 AV3

-0.17 TWD 6 AV3

+0.24 TWD 9 AV6

-0.09 TWD 5 AV3

+0.00 TWD 6 AV6

+0.00 TWD 7 AV3

+0.26 TWD 10 AV6

+0.00 TWD 7 AV3

+0.00 TWD 6 AV6

+0.00 TWD 8 AV3

+0.00 TWD 5 AV6

+0.00 TWD 8 AV3

+0.00 TWD 11 AV6

+0.00 TWD 9 AV6

+0.00 TWD 5 AV2

+0.00 TWD 7 AV6

+0.00 TWD 5 AV7

+0.00 EXT EXT TEC TEN TEC TEN TEC TEH TEC TEN TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEN TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEN TEC TEN TEC TEH TEC TEH TEC TEN TEC TEC TEH TEC TEN TEC TEN TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEH TEC TEN TEC TEN TEC TEN TEC TEH TEH TEC TEH TEC TEN TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEE TEC TEH TEC TEH TEC TEN TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH UTIL 1

UTIL 2

CAL #

21 8

8 6

2 2

2 2

2 1

1 1

1 1

1 52 52 52 52 52 52 52 52 52 52 54 16 14 19 31 31 31 31 31 29 29 29 27 27 27 28 25 19 2

2 1

1 1

1 2

2 2

52 52 52 53 53 53 53 53 55 24 22 19 18 18 16 16 16 16 14 14 14 19 19 19 19 31 31 31 LEG PROBE HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 610UL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 610UL COLD 61OUL COLD 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:32 Component: S/G A Page 9 of 73 Component: S/C A Page 9 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 9 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 63 106 0.27 0.16 63 110 0.39 0.13 63 112 0.14 63 114 0.19 0.54 0.19 63 116 0.13 63 128 0.13 63 130 0.12 63 136 0.13 0.09 63 146 0.18 63 150 0.15 63 152 0.18 0.13 0.11 63 154 0.13 0.15 0.12 63 156 0.35 0.14 0.45 0.39 0.34 64 11 0.22 64 13 0.14 0.26 0.52 64 15 0.14 0.22 64 17 0.12 64 33 0.18 64 39 0.11 64 47 0.10 0.13 64 49 0.14 64 55 0.16 0.14 64 63 0.10 0.15 64 75 0.23 64 93 0.16 64 97 0.14 64 99 0.12 0.10 64 101 0.14 0.23 0.14 64 103 0.16 0.19 64 105 0.44 0.12 0.13 64 109 0.14 64 111 0.16 0.29 64 113 0.15 64 115 0.14 0.31 64 117 0.14 64 119 0.21 0.16 64 121 0.15 64 125 0.12 64 137 0.13 0.19 64 153 0.37 0.25 0.13 64 155 0.20 0.33 0.33 64 157 0.19 0.13 64 159 0.15 0.11 65 12 0.16 0.43 DEG CHN 110 P2 134 P2 108 P2 60 P2 146 P2 130 P2 122 P2 141 P2 155 P2 99 P2 90 P2 119 P2 148 P2 125 P2 67 P2 107 P2 69 P2 85 P2 126 P2 127 P2 64 P2 108 P2 136 P2 109 P2 104 P2 107 P2 129 P2 86 P2 128 P2 116 P2 94 P2 123 P2 117 P2 121 P2 127 P2 144 P2 110 P2 140 P2 129 P2 138 P2 137 P2 129 P2 138 P2 128 P2 143 P2 135 P2 134 P2 146 P2 114 P2 122 P2 79 P2 86 P2 100 P2 71 P2 100 P2 94 P2 93 P2 107 P2 129 P2 112 P2 122 P2 97 P2 113 P2 123 P2 159 P2 141 P2 126 P2 123 P2 126 P2 116 P2 84 P2 133 P2 123 P2 121 P2 98 P2 73 P2 117 P2 75 P2 100 P2 122 P2 IND %TW TWD 10 TWD 7 TWD 15 TWD 6 TWD 6 TWD 8 TWD 17 TWD 8 TWD 5 TWD 6 TWD 5 TWD 5 TWD 4 TWD 8 TWD 7 TWD 8 TWD 6 TWD 5 TWD 6 TWD 7 TWD 6 TWD 14 TWD 7 TWD 17 TWD 15 TWD 14 TWD 9 TWD 6 TWD 11 TWD 18 TWD 7 TWD 10 TWD 5 TWD 7 TWD 4 TWD 4 TWD 5 TWD 5 TWD 6 TWD 5 TWD 4 TWD 6 TWD 8 TWD 6 TWD 6 TWD 5 TWD 4 TWD 6 TWD 9 TWD 6 TWD 6 TWD 7 TWD 14 TWD 5 TWD 5 TWD 6 TWD 7 TWD 12 TWD 6 TWD 7 TWD 13 TWD 7 TWD 9 TWD 7 TWD 7 TWD 5 TWD 5 TWD 8 TWD 15 TWD 11 TWD 6 TWD 8 TWD 12 TWD 12 TWD 8 TWD 5 TWD 7 TWD 5 TWD 7 TWD 16 LOCATION AV3

+0.00 AV6

+0.00 AV6

+0.00 AV3

+0.00 AV7

-0.06 AV7

-0.13 AV6

+0.08 AV3

+0.02 AVE

+0.00 AV6

+0.20 AV6

+0.00 AV7

+0.15 AV6

+0.00 AV6

-0.04 AVl

+0.00 AVI

-0.27 AV7

+0.11 AV8

-0.22 AVI

-0.24 AV3

-0.18 AV6

+0.00 AVI

-0.24 AV2

+0.00 AV6

+0.13 AV7

+0.20 AV8

-0.29 AV6

+0.00 AV2

-0.24 AV3

-0.11 AV6

+0.00 AV3

+0.00 AV6

+0.00 AV3

-0.11 AV6

+0.26 AV2

+0.09 AV2

+0.09 AV6

+0.24 AV6

+0.24 AV3

-0.11 AV6

+0.13 AV2

+0.00 AV6

-0.07 AV6

+0.09 AV6

+0.00 AV6

+0.00 AV3

+0.00 AV6

+0.00 AV7

+0.00 AV6

+0.00 AV3

+0.00 AV6

+0.00 AV3

+0.00 AV6

+0.00 AV3

+0.00 AV7

+0.00 AV2

+0.00 AV3

+0.00 AV6

-0.29 AV2

-0.04 AV6

-0.20 AV3

+0.00 AV3

+0.00 AV3

-0.24 AV6

+0.00 AV6

+0.00 AV2

+0.00 AV7

+0.00 AV6

+0.00 AV3

+0.00 AV6

+0.13 AV8

-0.27 AV7

+0.18 AV3

+0.04 AVI

-0.22 AV7

+0.15 AVI

+0.18 AV7

-0.26 AV6

+0.14 AVI

-0.11 AV2

+0.31 EXT EXT TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEN TEC TEH TEC UTIL 1

UTIL 2

CAL #

31 31 29 29 37 37 37 37 28 22 22 20 20 5

3 3

3 3

1 1

1 1

1 1

1 1

52 53 53 53 53 53 55 24 22 20 20 20 17 17 15 15 13 18 20 20 20 20 20 20 30 30 30 30 30 29 29 29 37 27 27 27 26 26 26 26 20 20 1

1 1

2 2

2 2

2 1

1 53 53 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD PROBE 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UJL 610UDL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TDL 610UDL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:32 Component: S/G A Page 10 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 10 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.27 0.49 65 14 0.17 0.33 0.61 0.29 0.15 65 16 0.15 0.20 65 34 0.13 65 48 0.27 65 58 0.22 65 70 0.20 0.14 0.15 65 74 0.12 0.13 65 84 0.15 0.19 65 94 0.24 65 96 0.25 65 98 0.26 0.15 65 100 0.10 65 102 0.37 65 104 0.13 0.17 0.13 65 106 0.20 0.26 0.24 65 108 0.22 0.56 0.21 65 110 0.22 0.44 0.16 65 112 0.19 0.30 0.10 0.11 65 114 0.11 65 116 0.13 0.49 0.36 65 118 0.14 0.15 65 120 0.20 0.11 65 126 0.12 65 128 0.21 65 130 0.12 65 134 0.19 65 136 0.12 65 138 0.14 65 152 0.18 65 154 0.11 0.18 65 156 0.18 0.12 0.14 65 158 0.12 0.38 0.20 66 13 0.15 66 15 0.22 0.44 0.53 0.19 66 33 0.24 66 35 0.14 66 43 0.23 66 45 0.09 66 51 0.12 66 53 0.13 0.15 66 55 0.15 66 59 0.15 0.17 66 61 0.22 DEG 101 113 79 135 124 131 147 121 136 123 132 136 129 134 127 135 133 122 118 109 125 119 128 117 125 80 60 76 67 94 104 112 115 103 98 107 76 123 127 52 121 112 120 118 123 135 90 69 85 153 92 72 98 107 136 122 83 94 84 99 88 112 120 118 72 130 132 121 136 117 68 131 146 141 135 134 116 137 143 118 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWD 11 TWD 17 TWD 7 TWD 12 TWD 19 TWD 11 TWD 6 TWD 7 TWD 8 TWD 4 TWD 9 TWD 8 TWD 8 TWD 5 TWD 6 TWD 5 TWD 5 TWD 5 TWD 6 TWD 9 TWD 9 TWD 10 TWD 6 TWD 4 TWD 13 TWD 5 TWD 6 TWD 5 TWD 7 TWD 9 TWD 9 TWD 10 TWD 19 TWD 9 TWD 10 TWD 16 TWD 7 TWD 9 TWD 13 TWD 5 TWD 6 TWD 6 TWD 6 TWD 18 TWD 15 TWD 8 TWD 8 TWD 10 TWD 6 TWD 5 TWD 11 TWD 7 TWD 11 TWD 6 TWD 7 TWD 7 TWD 5 TWD 7 TWD 7 TWD 5 TWD 6 TWD 5 TWD 13 TWD 8 TWD 6 TWD 9 TWD 15 TWD 18 TWD 8 TWD 8 TWD 5 TWD 8 TWD 4 TWD 5 TWD 5 TWD 6 TWD 6 TWD 6 TWD 6 TWD 8 LOCATION AV3

+0.33 AV6

-0.22 AVI

+0.00 AV2

+0.00 AV3

+0.00 AV6

  • +0.00 AV7

+0.00 AV2

+0.00 AV8

+0.00 AV6

+0.00 AV6

+0.09 AV6

+0.00 AV3

+0.00 AV6

+0.20 AV7

+0.04 AV6

+0.00 AV7

+0.15 AV3

+0.00 AV6

+0.00 AV6

+0.00 AV3

+0.00 AV6

+0.00 AV3

+0.00 AV6

+0.00 AV6

+0.00 AV6

+0.00 AV3

+0.00 AV2

+0.00 AV6

+0.00 AV3

+0.00 AV7

+0.00 AV7

+0.00 AV6

+0.11 AV3

+0.00 AV7

+0.00 AV6

+0.00 AV3

+0.00 AV7

-0.02 AV6

+0.13 AV3

-0.02 AV2

-0.02 AV3

-0.20 AV7

+0.00 AV6

+0.00 AV3

+0.00 AV7

+0.00 AV6

+0.00 AV6

+0.00 AV7

+0.09 AV6

+0.02 AV6

+0.00 AV6

+0.13 AV6

+0.00 AV6

+0.20 AV3

+0.00 AV6

-0.22 AV8

-0.18 AVl

+0.18 AV8

-0.24 AV6

-0.24 AVI

-0.27 AV8

+0.00 AV6

+0.00 AV3

+0.00 AVl

+0.00 AVl

+0.00 AV2

+0.00 AV3

+0.00 AV6

+0.00 AV6

+0.00 AV6

+0.00 AV6

-0.09 AV3

+0.24 AV6

+0.00 AV3

+0.00 AV6

+0.00 AV6

+0.00 AV3

+0.00 AV6

+0.11 AV6

+0.00 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC UTIL 1

UTIL 2

CAL #

53 53 52 52 52 52 52 52 52 23 19 17 13 13 13 13 13 11 11 18 18 20 20 20 20 30 30 30 30 30 30 29 29 29 29 29 29 27 27 27 27 27 27 27 27 25 25 25 25 24 21 21 21 19 19 4

2 2

2 2

2 2

2 2

52 52 52 52 52 2323 21 19 17 18 18 18 15 15 16 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 610OL 610UL 61OUL 610UL 61OUL 610UL 61OUL 610UL 61OUL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610DL 61OUL 610UL 610UL 610UL 610DL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 610UL 610OL 610UL 610UL 610UL 610OL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610DL 610UL 61OUL 610UL 610UL 610UL 61OUL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:32 Component: S/G A Page 11 of'73 Component: S/S A Page 11 of *73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 11 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 66 75 0.18 66 77 0.14 0.13 0.17 66 79 0.11 66 87 0.12 66 93 0.13 66 95 0.14 0.13 66 97 0.16 0.30 66 99 0.32 0.22 0.11 66 101 0.23 0.16 0.09 66 103 0.11 0.62 0.64 0.13 66 105 0.17 0.32 66 107 0.26 0.13 66 109 0.12 66 111 0.17 0.38 0.23 66 113 0.48 66 115 0.24 0.09 66 117 0.24 66 121 0.18 66 123 0.11 66 129 0.12 66 137 0.12 66 145 0.23 0.16 0.21 66 149 0.24 66 153 0.26 0.11 66 155 0.24 0.16 0.10 0.14 0.18 66 157 0.29 0.35 0.28 0.30 0.36 67 12 0.13 0.14 0.17 67 14 0.16 67 16 0.09 0.18 67 18 0.10 67 20 0.14 67 34 0.18 67 62 0.14 67 66 0.32 67 70 0.25 0.18 67 74 0.40 0.33 67 76 0.43 0.42 67 94 0.14 67 96 0.16 0.34 67 98 0.11 0.15 67 100 0.09 0.31 0.20 67 102 0.44 0.44 DEG CHN 140 P2 123 P2 128 P2 123 P2 134 P2 85 P2 73 P2 84 P2 71 P2 114 P2 93 P2 113 P2 89 P2 120 P2 95 P2 75 P2 76 P2 141 P2 130 P2 128 P2 137 P2 141 P2 133 P2 123 P2 129 P2 58 P2 88 P2 93 P2 92 P2 114 P2 119 P2 138 P2 133 P2 114 P2 62 P2 70 P2 105 P2 94 P2 102 P2 129 P2 106 P2 111 P2 65 P2 92 P2 112 P2 90 P2 103 P2 90 P2 114 P2 126 P2 101 P2 106 P2 92 P2 144 P2 148 P2 127 P2 128 P2 65 P2 130 P2 121 P2 137 P2 126 P2 84 P2 101 P2 127 P2 134 P2 118 P2 109 P2 119 P2 121 P2 110 P2 98 P2 112 P2 117 P2 132 P2 79 P2 113 P2 81 P2 115 P2 104 P2 IND %TW TWO 7 TWO 6 TWO 5 TWO 6 TWO 4 TWO 6 TWD 6 TWO 7 TWO 6 TWD 8 TWO 13 TWO 14 TWD 10 TWO 6 TWO 11 TWO 8 TWO 5 TWO 5 TWO 19 TWO 19 TWO 6 TWO 7 TWO 12 TWO 10 TWO 5 TWO 6 TWO 8 TWO 15 TWO 10 TWO 18 TWO 9 TWO 4 TWO 9 TWO 9 TWO 6 TWO 7 TWO 6 TWO 10 TWO 7 TWO 9 TWO 10 TWO 10 TWD 5 TWO 11 TWO 7 TWO 5 TWO 7 TWD 8 TWO 12 TWD 14 TWD 12 TWD 12 TWD 14 TWD 6 TWO 6 TWO 7 TWO 7 TWO 4 TWD 8 TWO 4 TWO 6 TWO 7 TWO 6 TWO 12 TWO 9 TWO 7 TWO 13 TWO 11 TWO 14 TWO 14 TWO 7 TWO 8 TWO 14 TWO 6 TWD 7 TWD 5 TWD 13 TWD 9 TWO 17 TWO 17 LOCATION AVG

+0.00 AV2

+0.00 AV3

+0.00 AVG

+0.00 AV3

+0.00 AV2

-0.20 AV6

+0.11 AV7

+0.00 AV3

+0.00 AV6

+0.00 AV3

+0.00 AV7

+0.00 AV3

+0.00 AV2

+0.00 AV6

-0.20 AV3

+0.00 AV2

-0.07 AV3

+0.00 AV6

+0.00 AV7

+0.00 AV8

+0.00 AV3

+0.00 AV6

+0.00 AV3

+0.00 AV6

+0.00 AV6

+0.00 AV6

+0.00 AV3

+0.00 AV2

+0.00 AV6

+0.00 AV3

-0.06 AV2

+0.11 AV6

+0.00 AV6

+0.00 AV3

+0.00 AV6

+0.00 AV7

+0.00 AV8

-0.07 AV7

-0.04 AVI

-0.07 AV6

+0.18 AV6

+0.15 AVI

+0.22 AVI

+0.20 AV3

+0.00 AV6

+0.13 AV7

+0.16 AV8

-0.22 AVl

-0.22 AV3

+0.00 AV6

-0.33 AV7

+0.02 AV8

+0.18 AV2

+0.00 AV6

+0.00 AV8

+0.00 AV6

-0.18 AV2

+0.00 AV7

+0.00 AV1

+0.13 AV6

+0.22 AV6

+0.20 AV6

+0.00 AV6

+0.31 AV3

+0.00 AV6

+0.00 AV6

+0.00 AV7

+0.24 AV3

+0.00 AV6

+0.00 AV3

-0.18 AV7

+0.00 AV3

+0.00 AV6

+0.00 AV3

+0.00 AV7

-0.13 AV6

+0.00 AV3

+0.00 AV6

+0.00 AV3

+0.00 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL #

14 14 14 14 14 17 17 17 17 19 19 19 19 19 19 19 19 31 31 31 31 31 31 31 31 29 29 29 29 27 37 37 28 25 25 21 19 5

5 5

3 2

2 1

1 1

1 1

1 1

1 1

1 52 52 52 53 53 53 55 55 24 16 16 14 14 14 14 14 14 17 17 17 19 19 19 19 19 19 19 LEG COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 61OUL 610UL 61OUL 610UL 610UL 61OUL 610UL 61OUL 61OUL 61OUL 61OUL 61OUL 610UL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 610UL 61OUL 61OUL 61OUL 610UL 61OUL 610UL 61OUL 610UL 61OUL 61OUL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement Bobbin AVB Wear Indications 1%

to 19%

(Imperfect Tubes)

QUERY: QueryMl 12/14/12 11:34:32 Component: S/G A Page 12 of 73, Enc. 2 Page 12 of7 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 67 104 0.42 0.49 67 106 0.11 0.10 67 108 0.12 0.32 0.21 67 110 0.51 0.55 0.17 67 112 0.11 0.17 0.22 0.26 67 116 0.14 67 118 0.10 0.11 67 122 0.13 67 124 0.11 67

.128 0.11 67 130 0.14 0.12 67 132 0.10 67 140 0.22 0.11 67 142 0.12 0.17 0.21 67 144 0.18 67 152 0.21 67 154 0.26 0.28 0.34 0.16 67 156 0.22 0.14 0.19 0.15 67 158 0.18 0.31 0.21 0.17 68 13 0.15 0.17 68 15 0.12 68 17 0.15 0.15 0.15 68 35 0.13 0.18 68 49 0.12 68 55 0.12 68 63 0.13 0.09 0.17 68 65 0.09 0.09 68 67 0.18 0.38 0.14 68 69 0.13 68 71 0.13 0.15 68 75 0.36 0.49 0.28 0.10 68 77 0.25 0.19 68 79 0.11 0.11 68 81 0.20 0.13 68 87 0.13 68 89 0.21 0.20 68 97 0.14 0.10 68 99 0.46 0.30 DEG 127 130 130 141 92 117 109 112 106 57 138 115 101 115 139 118 88 138 133 120 92 142 71 ill 61 72 115 93 71 75 105 125 123 88 130 88 103 72 100 116 1il 112 105 90 92 110 109 87 125 133 126 140 136 147 143 154 147 128 126 116 135 128 137 130 121 125 134 123 139 135 135 140 138 80 124 127 132 127 125 126 CHN P 2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWD 14 TWD 16 TWD 5 TWD 4 TWD 6 TWD 13 TWD 9 TWD 18 TWD 19 TWD 8 TWD 5 TWD 7 TWD 8 TWD 10 TWD 6 TWD 5 TWD 5 TWD 6 TWD 5 TWD 5 TWD 6 TWD 5 TWD 6 TWD 10 TWD 5 TWD 6 TWD 7 TWD 9 TWD 8 TWD 9 TWD 11 TWD 12 TWD 14 TWD 8 TWD 10 TWD 7 TWD 8 TWD 7 TWD 8 TWD 13 TWD 9 TWD 8 TWD 7 TWD 8 TWD 6 TWD 6 TWD 6 TWD 6 TWD 5 TWD 7 TWD 5 TWD 5 TWD 5 TWD 4 TWD 6 TWD 3 TWD 4 TWD 7 TWD 12 TWD 5 TWD 5 TWD 5 TWD 6 TWD 12 TWD 15 TWD 10 TWD 4 TWD 9 TWD 7 TWD 4 TWD 4 TWD 7 TWD 4 TWD 5 TWD 8 TWD 8 TWD 6 TWD 4 TWD 15 TWD 11 LOCATION AV2

+0.00 AV6

+0.00 AV3

+0.00 AV6

+0.00 AV6

+0.11 AV3

+0.00 AV2

+0.00 AV6

+0.00 AV3

+0.00 AV2

+0.00 AV7

-0.02 AV6

+0.19 AV3

-0.13 AV2

-0.08 AV2

-0.04 AV2

+0.00 AV3

+0.00 AV6

+0.24 AV2

+0.00 AV3

+0.00 AV6

+0.13 AV3

+0.00 AV6

+0.00 AV6

-0.07 AVI

+0.00 AV8

-0.29 AV6

+0.16 AV2

-0.13 AVI

-0.02 AVI

+0.11 AVl

+0.13 AV3

+0.00 AV6

+0.00 AV7

-0.24 AV2

+0.00 AV3

+0.00 AV6

-0.13 AV8

-0.24 AVI

-0.23 AV6

-0.28 AV7

+0.14 AV8

+0.16 AVl

+0.20 AV6

-0.20 AVI

+0.18 AVl

+0.13 AV2

+0.28 AV6

-0.24 AV3

-0.20 AV6

+0.00 AV6

+0.28 AV3

+0.00 AV3

+0.00 AV6

+0.07 AV7

+0.11 AV3

+0.00 AV6

+0.02 AV3

+0.00 AV6

+0.09 AV7

+0.13 AV2

+0.07 AV2

+0.00 AV3

+0.07 AV2

+0.09 AV3

+0.02 AV7

+0.00 AV8

+0.07 AV6

+0.02 AV7

+0.02 AV3

+0.00 AV6

+0.00 AV6

+0.00 AV3

+0.00 AV7

+0.00 AV3

+0.00 AV6

+0.00 AV6

+0.00 AV3

+0.00 AV6

+0.00 AV3

+0.00 EXT EXT UTIL 1

UTIL 2

TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH CAL 31 31 31 31 29 29 29 29 29 29 37 37 37 37 37 26 26 26 26 22 22 22 21 7

7 5

5 5

5 3

1 1

1 1

1 1

1 1

1 1

1 1

53 53 53 55 55 55 24 24 20 17 15 15 15 15 15 15 15 15 15 13 13 13 13 13 13 13 13 14 14 11 11 18 18 18 20 20 20 20

  1. LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610TDL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:32 Component: S/G A Page 13 of 73 Component: S/S A Page 13 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 13 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 68 101 0.44 0.12 0.11 0.09 68 103 0.20 0.34 0.12 68 105 0.19 0.32 0.16 68 107 0.18 0.17 0.27 0.13 68 109 0.15 0.13 68 111 0.45 0.38 68 113 0.19 68 115 0.38 68 117 0.15 68 121 0.19 68 147 0.12 68 149 0.18 68 153 0.24 0.38 0.26 0.16 0.14 68 155 0.65 0.46 0.19 68 157 0.33 0.42 0.67 0.39 0.23 69 14 0.19 0.26 0.25 0.24 69 56 0.28 69 62 0.09 69 68 0.12 69 70 0.13 0.27 69 72 0.10 0.15 0.12 69 74 0.22 0.23 0.21 69 76 0.20 69 88 0.42 0.49 0.20 69 92 0.16 0.09 69 94 0.22 69 96 0.14 0.31 69 98 0.13 0.19 0.26 0.22 0.26 69 100 0.33 0.17 0.27 0.10 0.30 69 102 0.12 0.16 0.20 69 104 0.29 0.49 0.37 69 106 0.22 0.25 0.19 DEG CHN 122 P2 139 P2 143 P2 130 P2 71 P2 98 P2 80 P2 70 P2 86 P2 118 P2 79 P2 64 P2 85 P2 57 P2 54 P2 90 P2 106 P2 106 P2 131 P2 118 P2 88 P2 115 P2 97 P2 116 P2 113 P2 109 P2 100 P2 125 P2 109 P2 117 P2 110 P2 102 P2 106 P2 126 P2 123 P2 111 P2 122 P2 114 P2 132 P2 109 P2 122 P2 118 P2 156 P2 144 P2 144 P2 129 P2 128 P2 143 P2 138 P2 136 P2 136 P2 134 P2 125 P2 122 P2 122 P2 136 P2 127 P2 101 P2 130 P2 120 P2 131 P2 135 P2 111 P2 132 P2 133 P2 101 P5 130 P2 131 P2 124 P2 124 P2 90 P5 146 P2 142 P2 144 P2 109 P2 113 P2 120 P2 102 P2 100 P2 70 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW 15 5

5 4

7 11 5

7 11 6

7 6

10 5

7 6

16 15 8

15 7

8 5

7 10 15 11 8

7 19 15 8

12 14 19 14 9

8 10 10 10 9

3 5

5 9

4 6

5 8

8 8

7 14 15 8

6 4

8 5

11 5

7 10 9

9 12 7

10 4

10 5

6 8

10 15 12 8

9 7

LOCATION AV6

+0.00 AV3

+0.00 AV2

+0.00 AV7

+0.00 AV7

+0.00 AV3

+0.00 AV2

-0.15 AV6

+0.00 AV3

+0.04 AV2

+0.04 AV6

+0.00 AV3

+0.00 AV2

+0.00 AVl

-0.04 AV7

+0.00 AV6

+0.00 AV7

+0.00 AV3

+0.00 AV7

-0.13 AV3

+0.00 AV7

+0.00 AV6

+0.00 AV6

+0.22 AV6

+0.22 AVI

+0.11 AV3

+0.00 AV6

+0.20 AV7

-0.24 AV8

-0.20 AV8

-0.15 AV6

-0.24 AVI

+0.15 AV8

+0.14 AV7

-0.11 AV6

-0.09 AV3

+0.13 AVl

-0.24 AVI

+0.00 AV2

+0.00 AV3

+0.00 AV6

+0.00 AV3

+0.42 AV6

+0.31 AV2

+0.07 AV3

+0.24 AV6

-0.24 AV3

+0.15 AV6

+0.17 AV7

+0.07 AV2

+0.15 AV3

+0.11 AV6

+0.20 AV6

+0.04 AV3

+0.00 AV6

+0.00 AV7

+0.00 AV3

+0.00 AV2

+0.00 AV6

+0.00 AV7

+0.00 AV3

+0.00 AV7

+0.00 AV6

+0.00 AV3

+0.00 AV2

+0.00 AV4

+1.97 AV7

+0.00 AV6

+0.00 AV3

+0.00 AVI

+0.00 AV4

+0.92 AV6

+0.00 AV3

+0.00 AV2

+0.00 AV7

+0.00 AV6

+0.00 AV2

+0.00 AV7

-0.07 AV6

+0.00 AV3

-0.26 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1 UTIL 2

LAR LAR CAL #

20 20 20 20 30 30 30 30 30 30 30 30 30 30 29 29 29 29 37 27 27 26 4

4 1

1 1

1 1

2 2

2 2

2 52 52 52 52 17 15 15 13 13 13 13 13 13 13 13 13 18 18 18 18 18 18 18 18 20 20 20 20 20 20 20 2O 20 20 20 20 20 30 30 30 30 30 30 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 61OUL 61OUL 61OUL 610UL 61OUL 610UL 61OUL 61OUL 61OUL 61EUL 61OUL 610UL 61OUL 610UL 61OUL 610UDL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61UL 61OUL 610UL 61OUL 610UL 61OUL 610UL 61OUL 61EUL 61OUL 61OUL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 61OUL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:33 Component: S/G A Page 14 of 73 Component: S/G A Page 14 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 14 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLT8 DEG 69 108 0.14 44 0.37 118 69 110 0.27 80 0.17 78 69 112 0.20 113 0.48 83 69 114 0.12 136 0.13 69 0.09 100 69 116 0.21 114 0.20 114 69 118 0.24 74 69 120 0.14 78 0.24 105 69 122 0.17 110 69 124 0.15 81 0.17 62 69 130 0.16 80 69 134 0.14 66 69 136 0.21 55 69 138 0.20 55 69 140 0.06 166 0.15 137 0.09 142 69 144 0.16 87 69 152 0.19 93 69 154 0.20 137 0.38 132 0.20 120 0.34 98 69 156 0.23 116 0.38 116 0.30 130 0.26 144 70 13 0.11 113 70 15 0.23 129 0.18 121 0.49 128 0.19 140 70 17 0.17 117 0.23 113 70 35 0.13 134 70 57 0.11 137 70 59 0.10 144 70 63 0.22 113 70 69 0.37 124 70 71 0.25 121 70 73 0.19 131 70 75 0.19 102 70 77 0.13 137 70 85 0.18 133 0.17 130 70 87 0.22 91 70 91 0.22 118 0.26 117 0.29 112 0.17 114 70 95 0.17 99 0.27 107 70 97 0.16 64 0.33 103 0.35 100 70 99 0.10 92 0.14 83 70 101 0.15 122 0.44 109 0.15 87 70 103 0.21 131 0.18 132 0.12 149 70 105 0.23 131 0.48 125 0.14 149 70 107 0.17 134 0.22 143 70 109 0.26 98 0.41 108 0.49 108 0.16 82 70 111 0.13 84 CHN IND P2 TWD P2 TWD PS TWD P2 TWD P2 TWD P5 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P5 TWD P2 TWD P5 TWD P5 TWD P2 TWD P5 TWD P5 TWD P2 TWD P5 TWD PS TWD P2 TWD P2 TWD P2 TWD P5 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2

'TWD P2 TWD P2 TWD P2 TWD P2 TWD

%TW LOCATION EXT EXT 7

AV8

+0.00 TEC TEN 14 AV7

+0.00 TEC TEH 11 AV4

+1.01 TEC TEH 8

AV6

+0.00 TEC TEH 9

AV6

+0.09 TEC TEH 15 AV4

+1.76 TEC TEH 6

AV3

+0.00 TEC TEH 6

AVI

+0.11 TEC TEH 5

AV6

-0.11 TEC TEH 9

AV3

+0.13 TEC TEH 9

AV6

+0.00 TEC TEH 7

AV4

+1.99 TEC TEH 7

AV3

+0.00 TEC TEH 7

AV4

+1.87 TEC TEH 5

AV4

+2.00 TEC TEH 8

AV3

+0.00 TEC TEH 5

AV6

+0.13 TEC TEH 6

AV6

-0.04 TEC TEH 8

AV3

+0.00 TEC TEH 7

AV4

+2.03 TEC TEH 7

AV4

+1.77 TEC TEH 3

AV8

+0.00 TEC TEH 6

AV7

+0.00 TEC TEH 3

AVI

+0.00 TEC TEH 6

AV6

+0.02 TEC TEH 7

AV6

-0.26 TEC TEH 8

AV6

-0.11 TEC TEH 13 AV3

+0.07 TEC TEH 8

AV2

-0.04 TEC TEH 12 AVI

+0.20 TEC TEH 9

AV8

+0.16 TEC TEH 13 AV6

-0.18 TEC TEH 11 AV3

+0.20 TEC TEH 10 AV2

+0.15 TEC TEH 5

AV6

+0.00 TEH TEC 9

AVi

+0.00 TEH TEC 8

AV2

+0.00 TEH TEC 17 AV7

+0.00 TEH TEC 8

AV8

+0.00 TEH TEC 7

AVl

+0.42 TEH TEC 9

AV2

+0.33 TEH TEC 4

AV4

-0.26 TEH TEC 4

AV6

+0.00 TEH TEC 4

AV6

+0.00 TEH TEC 8

AV6

+0.00 TEH TEC 13 AV6

+0.31 TEH TEC 9

AV6

+0.00 TEH TEC 7

AV6

+0.00 TEH TEC 7

AV2

+0.26 TEH TEC 5

AV2

+0.00 TEH TEC 7

AV3

+0.00 TEH TEC 7

AV6

+0.00 TEH TEC 10 AV7

+0.00 TEC TEH 10 AV7

+0.00 TEC TEH 11 AV6

+0.02 TEC TEH 12 AV3

+0.00 TEC TEH 8

AV2

+0.00 TEC TEH 8

AV3

+0.00 TEC TEH 12 AV2

+0.00 TEC TEH 8

AV7

+0.00 TEC TEH 14 AV6

+0.00 TEC TEH 15 AV3

+0.00 TEC TEH 5

AV5

-0.02 TEC TEH 7

AV3

+0.00 TEC TEH 7

AV7

+0.00 TEC TEH 17 AV6

+0.00 TEC TEH 7

AV3

+0.00 TEC TEH 8

AV2

+0.00 TEC TEH 7

AV3

+0.00 TEC TEH 5

AV6

+0.00 TEC TEH 9

AV2

+0.00 TEC TEH 16 AV3

+0.00 TEC TEH 6

AV8

+0.00 TEC TEH 7

AV2

+0.00 TEC TEH 9

AV6

+0.00 TEC TEH 11 AV8

+0.00 TEC TEH 15 AV7

+0.00 TEC TEH 17 AV6

+0.00 TEC TEH 7

AV3

+0.00 TEC TEH 6

AV6

+0.00 TEC TEH UTIL 1

UTIL LAR LAR LAR LAR LAR LAR LAR LAR LAR LAR 2

CAL 29 29 29 29 27 27 27 27 27 27 27 25 25 25 25 25 25 21 21 19 19 8

8 8

6 4

2 2

2 2

2 2

2 2

52 52 52 52 52 5454 23 17 15 16 16 14 14 14 14 12 12 17 17 17 17 17 17 17 19 19 19 19 19 19 19 19 31 31 31 31 31 31 31 31 29 29 29 29 29

  1. LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:33 Component: S/G A Page 15 of 73 Component: S/C A Page 15 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 15 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 70 113 0.12 0.25 70 117 0.13 0.13 0.14 70 121 0.15 0.11 70 123 0.37 0.14 70 129 0.14 70 131 0.21 70 133 0.10 0.26 70 135 0.11 70 153 0.13 0.21 0.16 70 155 0.15 0.34 70 157 0.13 0.11 71 14 0.23 0.49 0.25 71 18 0.15 71 20 0.12 71 66 0.21 71 70 0.25 71 72 0.14 0.25 71 74 0.20 0.16 0.22 0.16 71 76 0.21 0.15 0.27 0.63 0.66 0.14 71 78 0.26 0.20 0.11 71 80 0.11 71 84 0.12 0.11 71 88 0.13 0.18 0.18 71 90 0.11 71 92 0.15 0.14 71 94 0.10 0.11 71 96 0.12 0.14 0.12 0.35 71 98 0.15 0.23 0.44 0.21 0.21 0.12 71 100 0.23 0.13 0.10 0.17 0.11 71 102 0.13 0.12 0.46 0.29 0.33 0.20 71 104 0.16 0.48 71 106 0.11 71 108 0.17 0.18 DEG 69 128 140 148 143 116 109 108 94 81 68 62 98 71 ill 126 93 83 115 140 111 114 124 127 135 122 126 112 124 119 129 122 93 139 104 98 120 119 121 125 127 149 73 92 121 121 104 103 141 132 129 117 97 63 107 116 108 112 ill 112 127 95 83 102 82 113 104 88 127 100 116 96 117 94 121 125 143 99 91 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW 6

11 5

5 6

8 6

16 7

8 7

6 13 7

6 8

6 7

14 6

5 10 17 10 6

5 8

9 6

9 8

6 8

6 8

6 10 18 19 6

10 8

4 5

5 5

6 8

8 5

7 7

5 5

6 7

6 14 7

11 17 10 10 6

11 7

5 8

6 7

6 18 13 14 9

6 16 5

8 8

LOCATION AV7

+0.00 AV6

+0.00 AV7

+0.09 AV3

-0.11 AV2

+0.00 AV3

-0.07 AV2

-0.04 AV6

+0.00 AV3

+0.00 AV6

-0.22 AV6

+0.00 AV7

+0.00 AV6

+0.00 AV6

+0.00 AV6

-0.18 AV3

+0.13 AVM

+0.20 AV6

-0.29 AV7

-0.22 AV3

-0.27 AV6

+0.16 AV2

+0.00 AV3

+0.00 AV6

+0.00 AV4

+0.46 AV3

-0.07 AV6

+0.33 AV6

+0.00 AV5

+0.00 AV6

+0.00 AV4

+0.00 AV6

+0.00 AV7

+0.00 AV8

+0.00 AV3

+0.26 AV4

+0.35 AV5

-0.26 AV6

-0.15 AV7

+0.00 AV8

+0.00 AV2

-0.15 AV3

+0.00 AV7

+0.00 AV6

+0.00 AV3

+0.00 AV4

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV7

+0.04 AV6

-0.07 AV4

+0.00 AV5

-0.22 AV3

-0.29 AV7

+0.00 AV6

+0.00 AV3

+0.00 AV2

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV7

+0.00 AV6

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AVI

+0.00 AV5

+0.00 AV6

+0.00 AV4

+0.29 AV7

+0.00 AV6

+0.11 EXT EXT UTIL I UTIL TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH 2

CAL #

27 27 28 28 28 25 25 25 25 21 21 21 21 21 2

2 2

1 1

1 1

53 53 53 55 55 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 12 12 12 17 17 17 17 17 17 17 17 17 17 17 17 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 31 31 31 29 29 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 61OUL 61OUL 610UL 610UL 61OUL 610UL 61OUL 61OUL 61OUL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 61OUL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:33 Component: S/G A Page 16 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 16 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.31 0.41 0.11 71 110 0.12 71 114 0.13 71 116 0.29 0.16 0.15 0.10 0.09 71 118 0.11 71 150 0.15 71 152 0.16 0.13 0.20 71 154 0.19 0.15 71 156 0.19 72 15 0.32 0.13 0.26 0.28 0.14 0.23 0.15 72 17 0.21 0.11 0.15 72 35 0.16 72 41 0.12 72 63 0.13 0.13 72 65 0.12 72 69 0.21 0.10 72 71 0.19 72 73 0.22 0.15 0.16 0.21 72 75 0.13 0.38 0.36 0.39 0.16 0.15 72 77 0.22 0.14 0.37 0.33 0.29 72 79 0.27 0.14 0.13 0.39 0.16 0.44 72 83 0.16 72 85 0.09 72 89 0.24 0.40 72 91 0.31 0.28 0.28 0.23 0.15 0.38 0.17 72 93 0.18 0.30 72 95 0.19 0.22 72 97 0.12 0.17 0.08 72 99 0.13 0.12 0.09 72 101 0.43 0.22 DEG 123 110 85 88 140 134 128 142 150 148 118 104 46 73 105 101 65 91 112 94 90 137 104 127 93 133 75 128 113 136 141 148 152 124 108 136 129 129 110 130 130 132 126 119 120 129 121 129 130 122 124 118 123 116 122 125 118 115 140 99 121 109 119 131 139 133 121 117 116 126 126 119 121 138 144 116 142 148 133 129 CHN IND P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2.

TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD

%TW LOCATION 12 AV4

+0.22 15 AV3

+0.00 5

AV5

-0.04 6

AV3

+0.00 5

AV6

-0.09 11 AV5

+0.00 7

AV4

+0.26 6

AV3

+0.00 4

AV2

+0.09 4

AVl

+0.00 5

AV7

+0.00 7

AVl

+0.00 7

AVI

+0.00 6

AV6

-0.29 9

AV8

+0.00 9

AVi

+0.00 7

AV8

+0.00 9

AV8

+0.18 13 AV4

+0.00 6

AV5

-0.22 11 AV6

+0.00 11 AV7

+0.00 6

AVl

+0.00 10 AV2

+0.00 7

AV3

+0.00 8

AV2

+0.26 5

AV4

+0.33 6

AV5

+0.33 6

AV4

-0.22 5

AV2

+0.00 5

AV2

+0.00 5

AV6

+0.07 5

AV3

+0.00 7

AV7

+0.11 4

AV6

+0.24 7

AV3

+0.11 8

AV3

+0.00 6

AV4

+0.24 6

AV5

-0.04 8

AV6

+0.07 5

AV4

+0.07 13 AV6

+0.07 12 AV7

+0.09 13 AV8

+0.22 6

AV2

+0.09 6

AV3

+0.04 8

AV2

+0.00 5

AV4

+0.11 12 AV5

+0.04 11 AV6

+0.09 10 AV7

+0.00 10 AV2

-0.18 6

AV4

+0.24 5

AV5

-0.20 13 AV6

+0.00 6

AV7

+0.00 14 AV8

+0.00 6

AV3

+0.00 3

AV5

+0.00 9

AV3

+0.00 13 AV6

+0.00 11 AV8

+0.00 10 AV7

+0.00 10 AV6

+0.00 9

AV5

+0.00 6

AV4

+0.00 13 AV3

+0.00 6

AV2

+0.00 7

AV5

+0.00 11 AV3

+0.00 7

AV6

+0.00 8

AV4

+0.00 5

AV6

+0.07 7

AV2

+0.00 4

AV3

-0.04 5

AV6

+0.00 5

AV3

+0.00 4

AV2

+0.00 15 AV6

+0.00 9

AV5

+0.00 EXT TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC EXT TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEZ TEC TEC TEC TEC TEC TEC TEC TEC TEC.

TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH UTIL 1

UTIL 2

CAL 29 29 29 29 28 28 28 28 28 28 26 3

3 3

3 1

1 1

53 53 53 53 53 53 53 55 55 55 24 22 15 15 15 15 15 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 14 14 14 14 14 14 11 11 18 18 18 18 18 18 18 18 18 18 18 18 18 20 20 20 20 20 20 20 20

  1. LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 61OUL 61OUL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 6100L 610UL 610UL 61OUL 61OUL 61OUL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name:

St Lucie 2 Replacement 12/14/12 11:34:33 Component: S/G A Page 17 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 17 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 72 103 0.26 0.29 0.60 0.15 0.63 0.12 72 105 0.16 0.12 0.10 0.29 72 107 0.49 72 109 0.14 0.35 0.50 0.30 0.18 72 113 0.11 72 117 0.10

  • 0.19 72 119 0.11 0.11 72 141 0.19 72 151 0.20 0.26 72 153 0.24 0.18 72 155 0.20 0.13 0.19 73 16 0.13 0.15 73 18 0.28 0.19 0.19 0.18 73 44 0.14 73 48 0.14 73 62 0.15 0.12 73 70 0.18
0. 12 73 72 0.20 0.25 73 74 0.15 0.34 0.53 0.25 73 76 0.22 0.14 0.39 0.54 0.23 0.28 73 78 0.15 73 80 0.21 73 82 0.13 0.18 0.14 73 84 0.16 0.16 73 86 0.17 73 88 0.12 0.46 0.18 0.30 0.27 0.35 73 90 0.16 0.18 0.14 73 92 0.20 0.17 0.34 0.19 0.16 73 94 0.26 0.30 0.17 0.18 0.20 DEG 85 105 103 80 105 113 62 51 64 103 104 117 97 108 96 80 147 125 126 130 136 106 136 127 91 90 131 118 103 130 147 113 80 113 106 110 122 140 147 128 112 133 127 122 133 121 123 134 142 126 123 122 118 119 136 134 125 141 112 133 117 73 117 103 127 132 122 137 129 92 131 124 107 127 118 121 123 ill 121 132 CHN IND P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD

%TW 9

10 17 6

18 5

6 5

4 10 15 6

14 18 12 8

5 5

9 5

5 8

8 10 11 8

8 5

8 6

6 11 7

7 7

5 5

6 5

7 5

8 9

6 12 16 9

8 5

13 16 8

10 6

7 4

6 5

6 6

7 5

15 7

11 10 12 6

7 6

8 6

12 7

6 9

11 6

7 8

LOCATIO]

AV8 AV7 AV6 AV4 AV3 AV2 AV2 AV7 AV6 AV4 AV6 AV7 AV6 AV5 AV3 AV2 AV7 AV5 AV2 AV2 AV3 AV3 AV6 AV3 AVI AV3 AV7 AV5 AVI AVI AV8 AVI AV2 AV7 AV8 AV5 AV4 AV4 AV6 AV3 AV5 AV5 AV6 AV5 AV6 AV7 AV8 AVI AV2 AV4 AV5 AV6 AV7 AV5 AV6 AV5 AV6 AV7 AV3 AV4 AV4 AV2 AV3 AV4 AV5 AV6 AV7 AV7 AV5 AV2 AV6 AV5 AV4 AV3 AV2 AV6 AV5 AV4 AV3 AV2 N

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

-0.04

+0.00

+0.00

+0.04

+0.00

+0.00

+0.00

+0.00

+0.00

-0.15

+0.33

+0.00

-0.02

-0.22

-0.09

-0.04

+0.04

-0.22

+0.13

-0.13

+0.35

-0.27

+0.00

+0.00

+0.18

+0.26

+0.18

+0.00

+0.31

+0.13

+0.13

+0.11

+0.00

+0.00

+0.02

+0.15

+0.00

+0.11

+0.02

+0.02

+0.02

+0.00

+0.04

+0.07

+0.11

+0.09

-0.09

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00 EXT EXT TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEE TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEE TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL #

30 30 30 30 30 30 30 30 30 30 30 29 29 29 29 29 28 27 27 26 26 5

4 4

11 2

2 2

52 52 54 54 54 54 20 19 15 15 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 11 11 11 11 11 11 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD NOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl 12/14/12 11:34:33 Component: S/G A Page 18 of 73, Eno. 2 Page18 of 73 PSL-ENG-SESJ-12-006 Rev, 0 EC # 278014 Rev. 0 ROW COL VOLTS 73 96 0.22 0.30 0.18 73 98 0.12 0.32 0.15 0.17 73 100 0.16 0.12 0.45 73 102 0.20 0.32 0.15 0.17 73 104 0.70 0.69 0.26 0.30 0.24 73 106 0.19 0.15 0.18 0.30 0.28 0.24 73 108 0.11 0.27 0.15 0.25 0.36 73 110 0.13 0.14 73 112 0.22 73 118 0.15 73 128 0.12 73 130 0.12 73 134 0.13 0.14 0.10 73 138 0.12 73 140 0.13 0.10 0.14 73 154 0.19 0.19 0.23 74 17 0.15 0.23 0.15 74 21 0.14 0.14 74 23 0.13 74 35 0.15 0.14 0.14 74 55 0.25 0.11 74 57 0.15 74 63 0.16 74 67 0.16 0.44 0.23 74 69 0.23 0.16 0.18 74 71 0.20 0.25 0.50 0.57 0.19 74 73 0.32 0.48 0.50 0.25 0.18 74 75 0.12 0.45 0.25 0.30 0.32 DEG CHN 110 P2 123 P2 115 P2 145 P2 132 P2 130 P2 135 P2 144 P2 122 P2 125 P2 132 P2 133 P2 118 P2 133 P2 105 P2 108 P2 112 P2 105 P2 100 P2 115 P2 81 P2 113 P2 110 P2 108 P2 83 P2 90 P2 114 P2 78 P2 105 P2 106 P2 11 P2 73 P2 128 P2 52 P2 108 P2 84 P2 90 P2 109 P2 127 P2 121 P2 98 P2 161 P2 148 P2 123 P2 115 P2 124 P2 112 P2 128 P2 95 P2 117 P2 131 P2 94 P2 102 P2 70 P2 101 P2 123 P2 125 P2 136 P2 131 P2 103 P2 114 P2 117 P2 119 P2 103 P2 131 P2 124 P2 120 P2 125 P2 118 P2 126 P2 109 P2 119 P2 119 P2 132 P2 121 P2 131 P2 113 P2 109 P2 125 P2 110 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW LOCATION 8

AV7

+0.00 10 AV6

+0.00 7

AV5

+0.00 5

AV7

+0.00 11 AV6

+0.00 6

AV4

+0.00 7

AV2

+0.00 6

AV6

+0.00 5

AV5

+0.00 15 AV3

+0.00 8

AV7

+0.00 11 AV6

+0.00 6

AV3

+0.00 7

AV2.

+0.00 19 AV6

+0.00 19 AVS

+0.00 9

AV4

+0.00 10 AV3

+0.00 9

AV2

+0.00 7

AV7

+0.00 6

AV5

+0.00 7

AV4

+0.18 10 AV3

+0.00 10 AV2

+0.00 9

AVI

+0.00 5

AV7

+0.00 11 AV6

+0.00 7

AV5

+0.00 10 AV4

+0.13 14 AV3

+0.00 6

AV7

+0.00 7

AV6

+0.00 10 AV4

+0.11 8

AV3

+0.00 7

AV2

-0.07 7

AV7

+0.00 8

AV6

+0.00 8

AV3

+0.00 6

AV5

+0.00 6

AV7

+0.00 5

AV8

+0.00 4

AV6

+0.00 5

AV3

+0.00 8

AV8

-0.15 8

AV3

+0.09 9

AVI

-0.26 6

AVI

+0.18 9

AV2

+0.18 6

AV6

-0.15 6

AV4

+0.31 6

AV8

+0.00 6

AV4

+0.22 5

AV3

+0.00 5

AV4

+0.00 5

AV6

+0.00 10 AV4

-0.18 5

AV5

-0.09 5

AV6

+0.00 7

AV5

+0.00 6

AV5

+0.00 15 AV6

+0.00 9

AV7

+0.00 9

AV4

+0.00 7

AV6

+0.35 7

AV7

+0.33 8

AV2

+0.00 9

AV4

+0.28 16 AV6

+0.00 17 AV7

+0.00 7

AV8

+0.00 11 AV2

+0.00 15 AV4

+0.26 16 AV5

-0.20 9

AV6

+0.00 7

AV7

+0.00 5

AV2

+0.00 15 AV3

+0.00 9

AV4

+0.00 11 AV5

-0.24 11 AV6

+0.00 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC UTIL 1

UTIL 2

CAL #

18 18 18 20 20 20 20 20 20 20 20 20 20 20 30 30 30 30 30 30 30 30 30 30 30 29 29 29 29 29 29 29 27 25 21 21 21 21 21 19 8

8 8

2 2

2 54 54 54 55 55 54 23 23 23 18 18 17 16 16 16 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 61OUL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 6100L 61OUL 61OUL 610UL 610UL 610UL 610DL 61OUL 610UL 610UL 61OUL 610UL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 6100L 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 6100L 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:33 Component: S/G A Page 19 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 19 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.29 74 77 0.10 0.20 0.53 0.67 0.35 74 79 0.15 0.13 74 81 0.29 0.45 0.29 0.20 0.15 0.08 74 83 0.16 0.42 0.13 0.19 0.14 74 85 0.13 0.24 0.17 74 87 0.26 0.14 0.18 0.12 74 89 0.39 0.36 0.31 0.51 0.27 74 91 0.37 0.20 0.15 0.13 74 93 0.29 0.17 0.35 0.14 0.23 74 95 0.26 0.16 0.12 0.40 0.43 0.22 74 97 0.26 0.36 0.32 0.37 0.13 74 99 0.10 0.20 0.25 0.19 0.33 0.17 74 101 0.30 0.30 0.22 0.24 0.16 0.10 74 103 0.16 0.11 0.16 0.17 74 105 0.11 0.17 74 107 0.17 0.20 0.19 74 109 0.47 0.16 0.15 74 11 0.19 0.35 0.56 0.26 74 113 0.31 DEG CHN 115 P2 145 P2 127 P2 122 P2 118 P2 116 P2 97 P2 142 P2 118 P2 122 P2 126 P2 95 P2 126 P2 151 P2 126 P2 120 P2 129 P2 122 P2 147 P2 117 P2 118 P2 131 P2 107 P2 104 P2 107 P2 92 P2 109 P2 116 P2 102 P2 108 P2 108 P2 113 P2 77 P2 115 P2 86 P2 101 P2 99 P2 106 P2 117 P2 101 P2 122 P2 72 P2 99 P2 113 P2 106 P2 98 P2 117 P2 118 P2 116 P2 98 P2 99 P2 92 P2 73 P2 80 P2 104 P2 98 P2 80 P2 108 P2 97 P2 96 P2 109 P2 108 P2 113 P2 139 P2 144 P2 135 P2 143 P2 124 P2 129 P2 134 P2 119 P2 139 P2 101 P2 117 P2 102 P2 108 P2 115 P2 111 P2 85 P2 119 P2 IND %TW LOCATION TWD 10 AV7

-0.17 TWD 4 AV2

+0.00 TWD 8 AV4

+0.29 TWD 16 AV5

-0.20 TWD 19 AV6

+0.29 TWD 12 AV7

-0.22 TWD 6 AV4

+0.26 TWD 5 AV6

+0.00 TWD 11 AV2

+0.28 TWD 15 AV3

+0.00 TWD 11 AV4

+0.26 TWD 8 AV5

-0.22 TWD 6 AV6

+0.00 TWD 4 AV8

+0.00 TWD 7 AV2

-0.17 TWD 14 AV3

+0.00 TWD 5 AV4

+0.22 TWD 7 AV5

+0.00 TWD 6 AV6

+0.00 TWD 5 AV3

+0.00 TWD 9 AV4

+0.00 TWD 7 AV5

+0.00 TWD 11 AV5

+0.00 TWD 7 AV4

+0.00 TWD 8 AV3

+0.00 TWD 6 AV2

+0.00 TWD 15 AV7

-0.04 TWD 14 AVS

+0.00 TWD 13 AV4

-0.09 TWD 18 AV3

-0.02 TWD 12 AV2

-0.09 TWD 15 AV7

+0.00 TWD 9 AV6

+0.00 TWD 7 AV5

+0.00 TWD 6 AV3

+0.00 TWD 12 AV7

+0.00 TWD 8 AV6

+0.11 TWD 14 AV5

-0.04 TWD 7 AV4

+0.04 TWD 10 AV3

-0.02 TWD 11 AV7

+0.00 TWD 7 AV6

+0.00 TWD 6 AV5

+0.00 TWD 15 AV4

+0.00 TWD 16 AV3

+0.00 TWD 10 AV2

+0.00 TWD 12 AV6

+0.00 TWD 15 AV5

+0.00 TWD 14 AV4

+0.00 TWD 15 AV3

+0.00 TWD 7 AV2

+0.00 TWD 5 AV7

+0.00 TWD 10 AV6

+0.00 TWD 11 AV5

+0.00 TWD 9 AV3

+0.00 TWD 14 AV2

+0.00 TWD 8 AVI

+0.00 TWD 13 AV6

+0.00 TWD 13 AV5

+0.00 TWD 10 AV4

+0.00 TWD 11 AV3

+0.00 TWD 8 AV2

+0.00 TWD 5 AVI

+0.00 TWD 7 AV2

+0.00 TWD 5 AV5

+0.00 TWD 6 AV7

+0.00 TWD 7 AV8

+0.00 TWD 5 AV2

+0.00 TWD 7 AV4

+0.00 TWD 7 AV2

+0.00 TWD 8 AV3

+0.00 TWD 8 AV6

+0.00 TWD 17 AV8

+0.00 TWD 7 AV4

+0.13 TWD 7 AV3

-0.09 TWD 8 AV7

+0.00 TWD 14 AV6

+0.00 TWD 19 AV5

+0.00 TWD 11 AV4

+0.00 TWD 13 AV2

+0.00 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL 14 14 14 14 14 14 14 14 12 12 12 12 12 12 12 12 12 12 12 12 12 12 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 31 31 31 31 31 31 31 31 31 29 29 29 29 29 29 29 27

  1. LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 6100L 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610OL 610OL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 61OUL 61OUL 61OUL 610UL 61OUL 61OUL 6100L 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:33 Component: S/G A Page 20 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 20 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 74 117 0.12 74 123 0.17 0.18 74 135 0.10 74 139 0.14 0.13 0.13 74 153 0.19 0.13 0.23 75 16 0.22 0.15 0.13 75 18 0.21 0.43 0.28 75 44 0.21 75 56 0.25 75 66 0.23 0.37 0.18 75 70 0.18 0.41 75 72 0.18 0.22 0.60 0.64 75 74 0.28 0.27 0.24 0.13 75 76 0.46 0.66 0.16 75 78 0.29 0.16 0.23 0.22 0.16 75 80 0.14 0.16 0.14 75 82 0.14 75 84 0.09 0.25 0.25 0.14 75 86 0.35 0.17 0.18 0.25 0.11 75 88 0.25 0.12 0.18 75 90 0.16 0.10 0.17 0.35 0.17 75 92 0.36 0.13 0.34 75 94 0.28 0.46 0.38 0.18 75 96 0.34 0.41 0.24 0.17 75 98 0.13 0.28 0.33 0.36 75 100 0.20 0.44 0.46 0.23 0.07 DEG 142 116 104 53 94 69 110 105 127 110 136 137 108 ill 121 126 113 100 128 123 127 124 116 122 118 118 121 123 130 128 126 118 123 121 119 117 115 128 133 136 140 135 134 138 118 124 101 114 114 112 108 71 110 98 117 103 101 92 120 72 106 92 103 106 107 101 103 98 101 109 140 123 102 109 112 69 107 107 ill 58 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWD 5 TWD 9 TWD 10 TWD 6 TWD 7 TWD 7 TWD 7 TWD 8 TWD 5 TWD 9 TWD 9 TWD 7 TWD 6 TWD 8 TWD 15 TWD 11 TWD 7 TWD 10 TWD 9 TWD 13 TWD 7 TWD 7 TWD 14 TWD 7 TWD 8 TWD 18 TWD 19 TWD 10 TWD 10 TWD 9 TWD 5 TWD 15 TWD 19 TWD 6 TWD 10 TWD 6 TWD 9 TWD 8 TWD 6 TWD 6 TWD 6 TWD 6 TWD 6 TWD 4 TWD 10 TWD 10 TWD 6 TWD 14 TWD 8 TWD 8 TWD 11 TWD 5 TWD 11 TWD 6 TWD 8 TWD 8 TWD 5 TWD 8 TWD 14 TWD 8 TWD 14 TWD 6 TWD 14 TWD 12 TWD 17 TWD 15 TWD 8 TWD 14 TWD 16 TWD 11 TWD 8 TWD 7 TWD 12 TWD 14 TWD 15 TWD 9 TWD 17 TWD 18 TWD 11 TWD 4 LOCATION AV2

+0.00 AV6

+0.00 AV5

+0.00 AV3

+0.00 AV8

+0.00 AV5

+0.00 AV2

+0.00 AV8

-0.22 AV5

-0.27 AVI

-0.27 AV6

+0.00 AV7

+0.00 AV8

+0.00 AV2

+0.31 AV4

+0.22 AV6

+0.00 AV5

+0.28 AV4

+0.24 AV4

+0.22 AV5

-0.18 AV6

+0.00 AV6

+0.00 AV7

+0.35 AV2

+0.00 AV3

+0.00 AV4

+0.33 AV6

+0.00 AV4

+0.31 AV5

-0.18 AV6

+0.00 AV7

+0.00 AV3

+0.40 AV4

+0.29 AV6

+0.00 AV3

+0.00 AV4

+0.31 AV5

-0.13 AV6

+0.40 AV7

+0.00 AV4

+0.22 AV5

-0.18 AV6

+0.00 AV7

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.29 AV5

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV2

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV7

+0.00 AV4

+0.09 AV5

+0.15 AV6

+0.02 AV6

+0.00 AV5

+0.00 AV3

+0.00 AV2

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV7

+0.00 AV5

+0.00 AV4

+0.00 AV2

+0.00 AV8

+0.04 AV7

+0.00 AV6

+0.00 AV4

+0.00 AV2

+0.09 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL #

28 25 25 21 19 19 19 2

2 2

53 53 53 55 55 55 20 18 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 12 12 12 12 12 12 12 12 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 19 19 19 19 19 19 19 19 19 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT NOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 6100L 610UL 610UL 6100L 610UL 61OUL 6100L 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:33 Component: S/G A Page 21 of 73 Component: S/G A Page 21 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 21 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 75 102 0.20 0.35 0.34 0.16 75 104 0.56 0.44 0.28 0.63 75 106 0.30 0.35 0.40 75 108 0.13 0.32 0.58 0.45 0.10 75 110 0.24 75 112 0.13 75 116 0.31 75 118 0.14 75 140 0.18 0.16 75 142 0.22 75 144 0.24 75 146 0.14 0.16 75 148 0.15 75 150 0.16 0.26 0.14 75 152 0.15 0.27 0.21 75 154 0.25 0.19 0.15 0.23 0.28 76 17 0.12 0.21 0.15 76 19 0.15 0.14 76 21 0.14 0.15 76 31 0.20 76 33 0.21 76 35 0.15 76 41 0.13 0.13 76 45 0.16 76 55 0.10 0.20 76 59 0.30 0.24 0.29 76 61 0.12 0.20 76 63 0.18 0.17 0.22 76 65 0.22 0.23 76 67 0.17 76 69 0.32 0.09 0.14 76 71 0.35 0.54 0.58 0.12 0.18 76 73 0.17 76 75 0.37 0.45 0.50 0.52 0.15 76 77 0.13 0.22 DEG 86 ill 110 135 128 126 125 129 125 128 128 74 103 112 103 95 96 120 122 104 121 98 106 120 94 86 108 82 102 54 96 121 66 109 121 138 108 101 86 114 97 128 119 132 133 125 120 110 ill 152 96 153 109 117 88 98 110 134 134 122 131 145 121 108 123 81 107 131 122 119 139 141 137 125 125 115 125 123 141 128 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWD 10 TWD 15 TWD 14 TWD 8 TWD 18 TWD 15 TWD 11 TWD 19 TWD 11 TWD 12 TWD 14 TWD 6 TWD 13 TWD 19 TWD 16 TWD 5 TWD 10 TWD 5 TWD 11 TWD 6 TWD 8 TWD 8 TWD 9 TWD 10 TWD 6 TWD 7 TWD 7 TWD 7 TWD 11 TWD 6 TWD 7 TWD 11 TWD 9 TWD 11 TWD 8 TWD 7 TWD 10 TWD 12 TWD 5 TWD 8 TWD 6 TWD 6 TWD 6 TWD 6 TWD 6 TWD 7 TWD 8 TWD 6 TWD 5 TWD 5 TWD 6 TWD 4 TWD 7 TWD 11 TWD 9 TWD 11 TWD 5 TWD 7 TWD 7 TWD 6 TWD 8 TWD 8 TWD 8 TWD 6 TWD 11 TWD 3 TWD 5 TWD 12 TWD 16 TWD 17 TWD 5 TWD 7 TWD 6 TWD 12 TWD 14 TWD 15 TWD 16 TWD 6 TWD 5 TWD 8 LOCATIOI AV7 AV6 AV3 AV2 AV2 AV3 AV4 AV5 AV4 AVS AV6 AV6 AV5 AV4 AV3 AV2 AV4 AV6 AV5 AV4 AV6 AV5 AV3 AV5 AV5 AV4 AV5 AV5 AV3 AVI1 AVI AV2 AV8 AVI AV3 AV6 AV7 AV8 AVl AV2 AV6 AV4 AV6 AVI AV4 AV4 AV4 AV4 AV4 AV5 AV4 AV4 AV5 AV4 AV5 AV6 AV6 AV7 AV4 AVS AV6 AV2 AV5 AV5 AV4 AV5 AV6 AV2 AV3 AV4 AV5 AV6 AV3 AV2 AV3 AV4 AV7 AV8 AV2 AV4 N

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

-0.17

+0.13

+0.00

+0.13

+0.00

+0.24

-0.29

+0.15

-0.04

-0.25

-0.11

-0.31

-0.38

+0.02

+0.02

+0.00

+0.00

+0.00

-0.27

+0.00

-0.09

-0.31

+0.13

+0.00

+0.00

+0.00

-0.11

+0.22

-0.17

+0.26

+0.00

+0.15

+0.18

+0.24

+0.18

-0.18

+0.00

+0.00

+0.20

+0.00

+0.07

+0.00

-0.09

+0.26

+0.00

+0.20

+0.09

-0.09

+0.04

+0.00

+0.04

-0.09

+0.09

-0.15

+0.13

+0.07

+0.09

+0.04

-0.04

+0.02

+0.04

+0.09

+0.04

+0.07

+0.11

+0.07

+0.09

+0.00 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC UTIL 1

UTIL 2

CAL #

19 19 19 19 31 31 31 31 31 31 31 29 29 29 29 29 29 28 28 26 7

7 5

5 5

5 3

3 3

3 3

3 3

1 1

1 1

1 55 55 55 55 55 54 54 24 24 24 22 22 20 17 17 16 16 16 15 15 15 15 15 15 15 15 15 15 15 13 13 13 13 13 13 13 13 13 13 13 13 13 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD.

COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 61OUL 61OUL 61OUL 61OUL 610UL 61OUL 610UL 61OUL 61OUL 610UL 61OUL 61OUL 610UL 610UL 610UL 61OUL 61OUL 61OUL 610UL 61OUL 61OUL 610UL 610UL 610UL 61OUL 61OUL 61OUL 61OUL 61OUL 610UL 61OUL 61OUL 61OUL 610UL 610UL 61OUL 61OUL 61OUL 610UL 61OUL 610UL 61OUL 610UL 61OUL 610UL 61OUL 61OUL 610UL 61OUL 610UL 61OUL 61OUL 61OUL 61OUL 610UL 610UL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:33 Component: S/G A Page 22 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 22 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.14 0.25 0.28 76 79 0.25 0.13 76 81 0.'32 0.41 0.40 0.40 0.30 76 83 0.12 0.16 0.18 76 85 0.23 0.47 0.27 76 87 0.24 0.27 0.40 0.19 76 89 0.36 0.37 0.34 0.57 0.34 76 91 0.15 0.31 0.31 0.34 0.31 0.16 76 93 0.18 0.12 0.39 0.18 76 95 0.12 0.13 0.30 0.45 0.13 76 97 0.12 0.23 0.39 0.18 0.10 76 99 0.12 0.25 0.11 0.42 0.26 0.39 76 101 0.20 76 103 0.39 0.14 0.40 0.12 0.17 0.55 0.09 76 105 0.28 0.12 0.68 0.58 0.27 0.16 0.13 76 107 0.30 0.29 0.12 76 109 0.30 0.51 0.23 0.26 76 111 0.18 0.28 0.20 0.14 76 115 0.18 0.11 76 117 0.11 DEG 123 127 126 120 143 123 122 121 128 122 116 100 123 117 117 121 103 126 120 139 129 118 113 107 99 125 121 118 113 115 80 88 58 122 108 114 106 112 120 118 134 131 117 115 131 141 127 103 124 131 121 126 99 78 119 75 74 102 66 92 84 ill 98 103 47 86 99 88 90 90 103 96 89 99 105 116 116 114 103 54 CHN IND %TW LOCATION P2 TWD 5 AV5

-0.13 P2 TWD 9 AV6

+0.02 P2 TWD 10 AV7

+0.00 P2 TWD 9 AV4

+0.22 P2 TWD 5 AV2

-0.15 P2 TWD 10 AV3

+0.00 P2 TWD 12 AV4

+0.00 P2 TWD 12 AV5

+0.00 P2 TWD 12 AV6

+0.00 P2 TWD 10 AV7

+0.00 P2 TWD 4 AV2

+0.00 P2 TWD 6 AV3

+0.00 P2 TWD 6 AV7

+0.00 P2 TWD 8 AV3

+0.00 P2 TWD 14 AV4

+0.00 P2 TWD 9 AV5

+0.00 P2 TWD 9 AV4

+0.11 P2 TWD 10 AV5

+0.00 P2 TWD 13 AV6

+0.00 P2 TWD 7 AV7

+0.00 P2 TWD 12 AV6

+0.00 P2 TWD 12 AV5

+0.00 P2 TWD 12 AV4

+0.00 P2 TWD 17 AV3

+0.00 P2 TWD 12 AV2

+0.00 P2 TWD 6 AV7

+0.00 P2 TWD 11 AV6

+0.00 P2 TWD 11 AV5

+0.00 P2 TWD 12 AV4

+0.00 P2 TWD 11 AV3

+0.00 P2 TWD 6 AV2

+0.00 P2 TWD 7 AV5

+0.00 P2 TWD 5 AV4

+0.09 P2 TWD 13 AV3

+0.00 P2 TWD 7 AV2

+0.00 P2 TWD 5 AV7

+0.00 P2 TWD 5 AV5

+0.00 P2 TWD 11 AV4

+0.00 P2 TWD 14 AV3

+0.00 P2 TWD 5 AV2

+0.00 P2 TWD 5 AV7

+0.00 P2 TWD 9 AV6

+0.00 P2 TWD 13 AV4

+0.00 P2 TWD 7 AV3

+0.00 P2 TWD 4 AV2

-0.11 P2 TWD 5 AV8

-0.22 P2 TWD 9 AV7

+0.00 P2 TWD 5 AV6

+0.00 P2 TWD 14 AV5

+0.00 P2 TWD 10 AV3

+0.00 P2 TWD 14 AV2

+0.00 P2 TWD 8 AV3

+0.00 P2 TWD 13 AV7

-0.07 P2 TWD 6 AV6

+0.00 P2 TWD 13 AV5

+0.00 P2 TWD 5 AV4

+0.00 P2 TWD 6 AV3

+0.00 P2 TWD 16 AV2

+0.00 P2 TWD 4 AVI

-0.13 P2 TWD 10 AV7

+0.00 P2 TWD 5 AV6

+0.00 P2 TWD 19 AV5

+0.00 P2 TWD 17 AV4

+0.00 P2 TWD 10 AV3

+0.00 P2 TWD 6 AV2

+0.00 P2 TWD 5 AV8

+0.00 P2 TWD 10 AV6

-0.02 P2 TWD 10 AV4

+0.00 P2 TWD 5 AVl

-0.24 P2 TWD 12 AV7

+0.00 P2 TWD 18 AV6

+0.00 P2 TWD 10 AV4

+0.18 P2 TWD 11 AV3

+0.00 P2 TWD 8 AV7

+0.00 P2 TWD 12 AV6

-0.04 P2 TWD 9 AV5

+0.00 P2 TWD 6 AV4

+0.00 P2 TWD 9 AV4

+0.13 P2 TWD 6 AV3

+0.00 P2 TWD 5 AV5

+0.00 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL # LEG 13 COLD 13 COLD 13 COLD 14 COLD 14 COLD 11 COLD 11 COLD 11 COLD 11 COLD 11 COLD 11 COLD 11 COLD 11 COLD 11 COLD 11 COLD 11 COLD 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 20 HOT 20 HOT 20 HOT 20 HOT 20 HOT 20 HOT 20 HOT 20 HOT 20 HOT 20 HOT 20 HOT 20 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 29 HOT 29 HOT 29 HOT 29 HOT 29 HOT 29 HOT 29 HOT 29 HOT 27 HOT 27 HOT 27 HOT PROBE 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 6100L 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:33 Component: S/G A Page 23 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 23 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.12 76 121 0.21 76 125 0.15 76 143 0.21 76 145 0.18 76 147 0.16 76 151 0.13 76 153 0.21 0.43 0.28 0.21 0.30 77 18 0.15 0.27 0.14 0.37 77 20 0.13 77 22 0.16 77 36 0.20 77 56 0.19 77 60 0.27 77 64 0.16 0.13 77 68 0.10 77 70 0.17 0.33 0.33 0.21 77 72 0.20 0.17 0.50 0.14 77 74 0.16 77 76 0.17 0.33 0.63 0.35 0.26 77 78 0.22 0.37 0.34 77 80 0.31 0.17 0.23 0.26 0.36 77 82 0.18 77 84 0.15 0.15 0.40 0.24 77 86 0.17 0.21 77 88 0.26 0.14 0.13 0.16 0.39 77 90 0.23 0.20 0.57 0.41 0.28 0.24 77 92 0.11 0.57 0.63 0.61 0.45 0.54 0.31 77 94 0.30 0.65 0.55 0.46 0.30 0.40 77 96 0.36 0.26 0.16 DEG 121 119 144 119 115 90 76 107 129 109 93 104 87 ill 126 ill 108 97 124 108 129 138 104 143 144 129 132 120 143 135 127 140 141 139 129 115 122 129 121 125 129 133 123 131 123 118 122 109 117 118 112 102 143 ill 124 133 120 120 122 133 118 118 127 117 118 118 125 115 119 123 112 121 120 123 119 121 120 123 108 137 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD TWD TWQ TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW LOCATION 6

AV2

+0.00 9

AV5

-0.20 6

AV7

+0.00 9

AV5

+0.00 8

AV5

-0.26 7

AV5

-0.24 5

AVI

-0.18 9

AV3

+0.16 16 AV4

+0.00 12 AV5

+0.00 10 AV7

+0.00 12 AV8

-0.22 6

AVI

+0.22 10 AV2

+0.33 6

AV5

-0.13 13 AV6

-0.22 5

AV4

+0.00 7

AV4

+0.22 7

AV4

+0.20 7

AV4

+0.07 9

AV5

+0.00 6

AV3

+0.00 5

AV5

-0.13 4

AV7

+0.09 6

AV2

+0.00 11 AV3

+0.07 11 AV4

+0.00 8

AV5

+0.07 8

AV2

+0.09 6

AV3

+0.09 16 AV4

+0.09 5

AV7

+0.07 6

AV7

+0.11 6

AV2

+0.11 11 AV3

+0.07 18 AV4

+0.07 12 AV6

+0.07 9

AV7

+0.09 8

AV3

+0.07 12 AV4

+0.02 11 AV5

+0.11 10 AV3

+0.00 6

AV4

+0.00 8

AV5

+0.00 8

AV6

+0.00 11 AV7

+0.00 6

AV7

+0.00 5

AV2

+0.00 5

AV3

+0.00 12 AV4

+0.00 8

AV5

+0.00 7

AV5

-0.24 8

AV7

+0.00 9

AV2

+0.00 6

AV4

+0.00 5

AV5

+0.00 6

AV6

+0.00 13 AV7

+0.00 9

AV7

+0.00 8

AV6

+0.00 17 AV5

+0.00 14 AV4

+0.00 10 AV3

+0.00 9

AV2

+0.00 4

AV8

+0.00 17 AV7

+0.00 18 AV6

+0.00 18 AV5

+0.00 14 AV4

+0.00 16 AV3

+0.00 11 AV2

+0.00 11 AV7

+0.00 18 AV6

+0.00 17 AV5

+0.00 15 AV4

+0.00 11 AV3

+0.00 13 AV2

+0.00 12 AV6

+0.00 10 AV5

+0.00 6

AV3

+0.00 EXT TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEN TEN TEN TEN TEN TEN TEN TEN TEN TEN TEN TEN TEH TEN TEN TEN TEN TEN TEN TEH TEN TEN TEN TEN TEN TEN TEN TEN TEN TEH TEN TEN TEN TEN TEN TEN TEN TEN TEN TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC EXT TEH TEN TEN TEN TEH TEH TEN TEN TEH TEN TEN TEN TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEN TEH TEN TEH TEH TEH TEN TEH TEN TEH TEH TEH TEH TEH TEH TEH TEN TEH TEH TEH TEN TEH TEN TEH TEN TEN TEN TEN TEN UTIL 1

UTIL 2

CAL 27 26 26 6

6 4

4 1

1 1

1 1

54 54 54 54 54 54 21 17 15 15 15 15 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 11 11 11 11 11 11 11 11 11 11 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18

  1. LEG PROBE HOT 610UL HOT 610UL HOT 610UL HOT 610UL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 610UL COLD 61OUL COLD 61OUL COLD 610UL COLD 61OUL COLD 610UL COLD 610UL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 610UL COLD 61OUL COLD 610UL COLD 61OUL COLD 610UL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 610UL COLD 61OUL COLD 610UL COLD 61OUL COLD 61OUL COLD 610UL COLD 61OUL COLD 61OUL COLD 61OUL COLD 610UL COLD 610UL COLD 61OUL COLD 61OUL COLD 610UL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 610UL HOT 610UL HOT 61OUL HOT 61OUL HOT 61OUL HOT 610UL HOT 610UL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 610UL HOT 610UL HOT 610UL HOT 610UL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 610UL HOT 61OUL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:33 Component: S/G A Page 24 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 24 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.31 77 98 0.15 0.15 0.31 0.55 77 100 0.13 0.23 0.33 0.11 0.10 0.10 77 102 0.45 0.63 0.11 77 104 0.41 0.22 0.28 0.59 0.13 77 106 0.52 0.62 0.43 0.23 77 108 0.47 0.42 0.11 77 110 0.13 0.14 0.18 77 112 0.16 0.18 0.42 0.14 77 114 0.19 0.46 0.27 0.11 77 116 0.15 0.14 0.27 0.32 0.12 77 118 0.14 0.18 77 134 0.17 0.13 0.11 77 138 0.37 77 140 0.14 0.13 0.17 77 144 0.16 77 146 0.21 77 152 0.17 77 154 0.20 78 17 0.20 78 19 0.15 78 23 0.20 78 35 0.11 78 45 0.33 78 49 0.13 78 63 0.15 0.25 78 67 0.14 0.21 78 69 0.35 0.34 78 71 0.12 0.31 0.10 0.32 0.25 0.43 0.22 78 73 0.16 0.64 0.19 0.34 0.30 0.49 DEG CHN 119 P2 132 P2 133 P2 126 P2 123 P2 140 P2 140 P2 130 P2 131 P2 146 P2 141 P2 123 P2 124 P2 115 P2 102 P2 103 P2 91 P2 99 P2 92 P2 102 P2 98 P2 104 P2 77 P2 108 P2 106 P2 115 P2 82 P2 114 P2 59 P2 104 P2 94 P2 118 P2 93 P2 121 P2 116 P2 116 P2 143 P2 114 P2 127 P2 104 P2 106 P2 113 P2 75 P2 65 P2 101 P2 73 P2 73 P2 101 P2 149 P2 136 P2 140 P2 118 P2 123 P2 104 P2 99 P2 127 P2 140 P2 131 P2 110 P2 111 P2 96 P2 115 P2 122 P2 82 P2 98 P2 126 P2 106 P2 137 P2 124 P2 132 P2 123 P2 107 P2 119 P2 133 P2 141 P2 121 P2 115 P2 125 P2 126 P2 121 P2 IND %TW TWD 11 TWD 6 TWD 6 TWD 11 TWD 17 TWD 5 TWD 9 TWD 12 TWD 5 TWD 4 TWD 4 TWD 15 TWD 19 TWD 5 TWD 13 TWD 8 TWD 10 TWD 17 TWD 5 TWD 16 TWD 18 TWD 14 TWD 8 TWD 17 TWD 16 TWD 5 TWD 6 TWD 6 TWD 8 TWD 7 TWD 9 TWD 16 TWD 7 TWD 9 TWD 17 TWD 12 TWD 5 TWD 7 TWD 7 TWD 12 TWD 13 TWD 6 TWD 8 TWD 9 TWD 10 TWD 8 TWD 7 TWD 15 TWD 5 TWD 5 TWD 6 TWD 7 TWD 9 TWD 7 TWD 9 TWD 8 TWD 6 TWD 8 TWD 4 TWD II TWD 5 TWD 6 TWD 10 TWD 6 TWD 8 TWD 12 TWD 12 TWD 5 TWD 11 TWD 4 TWD II TWD 9 TWD 14 TWD 8 TWD 6 TWD 19 TWD 7 TWD 12 TWD 11 TWD 16 LOCATION AV2 AV7 AV6 AV3 AV2 AV7 AV6 AV3 AV4 AVI AV2 AV6 AV4 AV3 AV5 AV4 AV3 AV2 AVI AV6 AVS AV3 AV2 AV5 AV4 AV3 AV8 AV7 AV5 AV6 AV5 AV4 AV3 AV7 AV5 AV4 AV3 AV7 AV6 AV4 AV3 AV2 AV5 AV4 AV3 AV5 AV4 AV5 AV8 AVS AV4 AV5 AV2 AV8 AVI AV2 AV4 AV4 AVS AV4 AV4 AV2 AV3 AV2 AV6 AV3 AV4 AV1 AV2 AV3 AV4 AV5 AV6 AV7 AV2 AV3 AV4 AVS AV6 AV7

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

-0.04

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

-0.04

+0.04

-0.09

+0.00

+0.00

-0.18

-0.04

+0.00

+0.00

+0.00

+0.13

+0.02

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

-0.13

+0.02

+0.11

-0.29

+0.20

+0.00

+0.00

+0.00

+0.24

-0.13

+0.00

+0.00

+0.00

+0.00

+0.00

-0.26

+0.00

+0.00

+0.00

-0.20

+0.35

+0.00

+0.33

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC UTIL 1

UTIL 2

CAL #

18 20 20 20 20 20 20 20 20 20 20 20 20 20 30 30 30 30 30 30 30 30 30 29 29 29 29 29 29 27 27 27 27 2.7 27 27 27 27 27 27 27 27 25 25 21 21 21 19 8

8 8

6 6

4 1

54 54 54 23 19 19 16 16 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 610UL 610UL 61OUL 610UL 61OUL 610UL 610UL 610TUL 610UL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 6100L 610UL 610UL 610UDL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:33 Component: S/G A Page 25 of 73 Bobbin AVB Wear Indications 1% to 19%

Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 25 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 78 75 0.25 0.52 0.21 0.62 0.56 0.32 78 77 0.28 0.30 0.50 0.52 0.25 78 79 0.16 0.44 0.25 0.54 0.21 78 81 0.14 78 83 0.14 0.32 0.20 0.28 0.28 0.18 78 85 0.14 0.29 0.28 0.18 78 87 0.16 0.36 0.14 0.28 78 89 0.34 78 91 0.23 0.16 0.23 78 93 0.16 0.23 0.19 0.14 78 95 0.22 0.52 0.29 0.14 78 97 0.18 0.21 0.36 0.13 78 99 0.43 0.39 0.42 0.38 78 101 0.17 0.40 0.14 0.12 78 103 0.24 0.13 78 105 0.31 0.23 78 107 0.14 78 109 0.15 0.46 0.59 78 111 0.42 0.31 0.37 0.12 78 113 0.20 0.16 78 117 0.38 78 121 0.19 78 123 0.10 78 137 0.21 78 139 0.10 0.18 0.11 78 143 0.27 78 145 0.19 78 147 0.16 78 151 0.15 DEG CHN 137 P2 122 P2 123 P2 119 P2 126 P2 121 P2 125 P2 111 P2 122 P2 125 P2 126 P2 121 P2 125 P2 121 P2 119 P2 121 P2 129 P2 147 P2 126 P2 119 P2 121 P2 99 P2 126 P2 135 P2 124 P2 109 P2 124 P2 88 P2 93 P2 96 P2 96 P2 108 P2 70 P2 95 P2 92 P2 95 P2 92 P2 113 P2 88 P2 101 P2 113 P2 114 P2 99 P2 90 P2 80 P2 114 P2 98 P2 107 P2 105 P2 110 P2 124 P2 91 P2 106 P2 69 P2 121 P2 131 P2 135 P2 136 P2 142 P2 130 P2 56 P2 99 P2 108 P2 109 P2 95 P2 101 P2 107 P2 103 P2 104 P2 117 P2 54 P2 66 P2 69 P2 75 P2 80 P2 102 P2 121 P2 106 P2 95 P2 84 P2 IND %TW TWD 9 TWD 16 TWD 8 TWD 18 TWD 17 TWD 11 TWD 10 TWD 11 TWD 16 TWD 16 TWD 9 TWD 6 TWD 14 TWD 9 TWD 17 TWD 8 TWD 6 TWD 6 TWD 11 TWD 8 TWD 11 TWD 10 TWD 7 TWD 6 TWD 11 TWD 10 TWD 7 TWD 8 TWD 14 TWD 7 TWD 12 TWD 14 TWD 10 TWD 8 TWD 10 TWD 7 TWD 10 TWD 9 TWD 7 TWD 10 TWD 19 TWD 12 TWD 7 TWD 9 TWD 10 TWD 15 TWD 7 TWD 17 TWD 16 TWD 17 TWD 16 TWD 8 TWD 16 TWD 7 TWD 6 TWD 9 TWD 5 TWD 12 TWD 9 TWD 6 TWD 7 TWD 17 TWD 19 TWD 16 TWD 13 TWD 14 TWD 6 TWD 9 TWD 8 TWD 13 TWD 10 TWD 6 TWD 10 TWD 5 TWD 9 TWD 6 TWD 11 TWD 8 TWD 7 TWD 7 LOCATION AV2

+0.00 AV3

+0.31 AV4

+0.00 AV5

-0.20 AV6

+0.00 AV8

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.31 AV6

+0.00 AV7

+0.00 AV3

+0.33 AV4

+0.00 AV5

+0.00 AV6

-0.18 AV7

+0.00 AVS

+0.00 AV2

-0.17 AV3

+0.00 AV4

+0.00 AV5

+0.32 AV6

+0.00 AV7

-0.19 AV3

+0.00 AV4

-0.13 AV5

-0.18 AV6

+0.31 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV7

+0.00 AV6

-0.04 AV5

-0.04 AV4

-0.13 AV5

+0.04 AV4

-0.13 AV3

+0.00 AV2

-0.04 AV5

+0.00 AV4

+0.00 AV2

+0.00 AV1

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV7

+0.00 AV7

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV7

+0.00 AV6

+0.00 AV3

+0.00 AV2

+0.00 AV6

+0.00 AV7

+0.00 AV6

+0.00 AV7

+0.00 AV6

+0.00 AV7

+0.00 AV6

+0.00 AV4

+0.22 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV6

+0.00 AV5

+0.20 AV5

+0.24 AV5

+0.00 AVS

+0.00 AV5

+0.00 AV7

+0.00 AV5

+0.00 AV3

+0.00 AV5

-0.31 AV5

-0.29 AV4

-0.07 AVl

-0.24 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 12 12 12 12 12 12 12 12 12 12 12 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 19 19 19 19 19 19 19 19 19 19 19 19 31 31 31 31 31 29 29 29 29 29 29 29 27 27 28 25 25 19 19 19 19 5

5 3

3

  1. LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:33 Component: S/G A Page 26 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 26 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.17 78 153 0.17 0.13 0.20 79 18 0.14 0.12 0.14 0.16 0.13 79 20 0.11 0.13 0.16 0.13 79 22 0.17 79 32 0.12 79 34 0.11 79 36 0.25 79 46 0.22 0.14 79 50 0.16 79 56 0.13 79 64 0.19 0.14 79 68 0.29 0.27 79 70 0.13 0.26 0.26 79 72 0.39 0.30 0.44 0.34 0.23 79 74 0.28 0.64 0.44 0.16 79 76 0.13 0.27 0.48 0.50 0.62 0.21 0.14 79 78 0.23 0.17 0.33 0.18 0.24 0.43 0.19 79 80 0.25 0.19 0.37 0.27 0.20 79 82 0.23 0.19 0.25 0.16 0.13 79 84 0.14 0.11 0.11 79 86 0.27 0.13 0.23 0.31 0.13 79 90 0.24 0.35 0.31 0.17 0.29 0.26 79 92 0.23 0.43 0.17 79 94 0.16 0.57 DEG 112 116 104 117 93 74 95 122 143 145 132 129 127 138 122 90 109 136 147 58 140 102 99 125 122 141 128 123 122 126 121 127 131 106 113 123 114 123 115 117 ill 120 115 124 125 132 127 134 136 112 101 127 122 120 128 136 133 134 119 137 126 115 108 136 78 102 ill 93 70 91 113 88 84 96 103 110 116 82 116 106 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWD 8 TWD 7 TWD 6 TWD 8 TWD 6 TWD 5 TWD 6 TWD 7 TWD 5 TWD 5 TWD 5 TWD 6 TWD 5 TWD 7 TWD 5 TWD 4 TWD 9 TWO 8 TWD 5 TWD 6 TWD 5 TWD 8 TWD 6 TWD 11 TWD 10 TWD 5 TWD 10 TWD 10 TWD 13 TWD 11 TWD 14 TWD 12 TWD 9 TWD 10 TWD 19 TWD 14 TWD 6 TWD 5 TWD 10 TWD 15 TWD 16 TWD 18 TWD 8 TWD 6 TWD 8 TWD 6 TWD 11 TWD 7 TWD 9 TWD 14 TWD 7 TWD 10 TWD 7 TWD 13 TWD 10 TWD 8 TWD 9 TWD 7 TWD 9 TWD 6 TWD 5 TWD 6 TWD 5 TWD 5 TWD 11 TWD 6 TWD 10 TWD 13 TWD 6 TWD 11 TWD 14 TWD 13 TWD 8 TWD 12 TWD 11 TWD 10 TWD 16 TWD 8 TWD 8 TWD 19 LOCATION AV3

+0.00 AV8

+0.13 AV3

+0.15 AVI

-0.29 AVI

+0.22 AV2

+0.26 AV5

-0.15 AV6

-0.13 AV3

+0.00 AV2

+0.00 AV4

+0.31 AV7

+0.00 AV8

+0.00 AV4

+0.00 AV4

+0.22 AV5

+0.24 AV4

+0.20 AVI

+0.00 AV4

+0.22 AV4

+0.17 AV6

+0.00 AV5

+0.00 AV6

+0.00 AV3

+0.00 AV7

+0.00 AV3

+0.00 AV5

+0.31 AV6

+0.00 AV3

+0.00 AV4

+0.31 AV5

-0.15 AV6

-0.20 AV7

+0.24 AV4

+0.00 AV5

+0.37 AV7

+0.00 AV8

+0.00 AV2

+0.31 AV3

+0.31 AV4

+0.00 AV5

+0.00 AV6

-0.18 AV8

+0.00 AVI

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AVE

+0.35 AV7

+0.00 AV8

+0.00 AV3

+0.00 AV4

+0.24 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV4

+0.27 AV5

-0.16 AV6

+0.00 AV7

+0.31 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV2

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV2

-0.09 AV5

-0.07 AV7

+0.00 AV8

+0.00 AV7

+0.00 EXT EXT UTIL 1

UTIL 2

TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH CAL 3

2 2

2 55 55 55 55 55 55 55 55 55 55 24 24 22 20 20 20 18 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 12 12 12 12 12 12 12 12 12 12 12 12 12 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17

  1. LEG HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610TDL 610UL 61OUL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TDL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 61OUL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:33 Component: S/G A Page 27 of 73 Bobbin AVB Wear Indications 1% to 19%

Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 27 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.33 0.41 0.54 0.52 0.34 79 96 0.53 0.21 0.46 79 98 0.16 0.32 0.44 0.44 0.31 79 100 0.14 0.17 79 102 0.18 0.37 0.17 79 104 0.19 0.33 0.33 0.15 0.12 0.17 79 106 0.54 0.35 0.36 0.22 79 108 0.18 0.13 0.33 0.14 79 114 0.15 79 118 0.14 0.12 0.09 79 132 0.12 79 134 0.22 79 138 0.17 79 146 0.14 79 152 0.16 80 19 0.11 80 21 0.18 0.18 80 29 0.20 80 31 0.16 80 33 0.16 80 35 0.12 80 45 0.19 80 67 0.14 0.36 0.18 80 69 0.17 80 71 0.14 0.33 0.24 0.27 80 73 0.24 0.38 0.39 0.59 0.53 80 75 0.12 0.22 0.61 0.56 0.62 80 77 0.'22 0.62 0.64 0.50 0.59 80 79 0.27 0.14 80 81 0.18 0.17 0.14 80 83 0.16 0.33 0.36 DEG 101 103 ill 109 107 112 91 95 90 102 112 109 103 69 103 84 117 103 113 126 135 114 131 145 121 127 133 136 131 47 107 92 129 114 143 125 147 137 107 118 78 66 144 132 114 133 124 96 106 127 134 142 138 136 122 127 136 128 116 116 121 123 135 129 119 117 120 133 119 125 123 125 108 129 128 137 146 99 117 123 CHN IND P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD

%TW LOCATION 13 AV6

+

16 AV5

+

19 AV4

+

19 AV3

+

14 AV2

+

19 AV6

+

9 AV5

+

17 AV2

+

8 AV8 14 AV7

+

17 AV6

+

17 AV3

+

13 AV2

+

7 AV5 8

AVI 9

AV7 15 AV6

+

8 AV2 8

AVI 12 AV2

+

12 AV3

+

6 AV4

+

5 AV7 7

AV8 17 AV3

+

12 AV5

+

13 AV6

+

9 AV7

+

8 AV7 6

AV5 13 AV4

+

6 AVI 6

AV6 6

AV5 6

AV7 4

AV2 5

AV2 9

AV3 7

AV5 6

AV8 7

AV8 5

AVI 7

AVl

+

7 AV4 7

AV4 6

AV4 6

AV4 5

AV4 7

AV4 5

AV4 1

12 AVS 1

7 AV6 1

6 AV4

+

5 AV2

+

11 AV3 A

9 AV6 10 AV7

+

9 AV3 13 AV4 13 AV5 1

18 AV6 16 AV7 1

5 AV2 8

AV4 18 AV5 17 AV6 18 AV7

+

8 AV2 1

18 AV3 19 AV4 16 AV5 17 AV6 10 AV4 6

AV6 6

AV3 6

AV7 5

AV8 6

AV2 10 AV3 11 AV4

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.04

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00 10.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00 10.00 10.00

-0.00

-0.00

-0.00 10.00 10.13

-0.15 10.00 10.00 10.00 10.00

-0.28

-0.02

10. 13

-0.16 10.00 0O.00 0O.24 10.22 0O.18

-0.11 0O.24 0O.02 0O.00 10.02 0O.07 0O.00 0O.13 0O.04 10.11

+0.00 0O.09 10.13 0O.11 0.02 0.09

+0.04

+0.04

+0.07

+0.09

+0.04

+0.09

+0.04

+0.09

+0.09

-0.22

[0.00

+0.00

[0.00

+0.00

+0.00

+0.00

+0.00 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC UTIL 1

UTIL 2

CAL 17 17 17 17 17 17 17 17 19 19 19 19 19 19 19 19 19 19 31 31 31 31 31 31 31 31 31 31 29 29 29 29 28 26 26 26 22 20 5

3 55 54 54 24 24 24 24 20 15 15 15 15 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 14 14 11 11 11 11 11 ii

  1. LEG PROBE HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 610UL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL HOT 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 61OUL COLD 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:33 Component: S/G A Page 28 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 28 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.56 0.43 0.57 0.12 80 85 0.24 0.26 0.17 0.42 0.20 80 87 0.55 0.23 0.32 0.25 0.16 0.36 80 89 0.17 0.60 0.21 80 91 0.37 0.21 0.20 0.13 80 93 0.16 0.22 0.19 0.09 80 95 0.60 0.69 0.51 0.16 80 97 0.48 0.26 0.17 80 99 0.15 0.52 0.53 0.29 0.22 0.30 80 101 0.17 0.11 0.19 0.55 0.64 0.40 0.36 0.14 80 103 0.57 80 105 0.10 0.23 0.44 0.12 0.30 80 107 0.41 0.17 0.17 80 109 0.13 0.21 0.41 0.12 0.25 80 111 0.18 0.23 0.24 80 113 0.16 80 115 0.12 0.11 80 117 0.14 0.15 0.27 80 123 0.12 80 125 0.15 80 133 0.15 80 135 0.09 80 137 0.14 0.19 80 141 0.14 80 145 0.10 81 18 0.13 81 22 0.20 DEG CHN 121 P2 121 P2 118 P2 105 P2 117 P2 116 P2 120 P2 120 P2 100 P2 119 P2 124 P2 123 P2 110 P2 114 P2 125 P2 129 P2 123 P2 113 P2 119 P2 121 P2 93 P2 98 P2 87 P2 127 P2 124 P2 122 P2 117 P2 113 P2 114 P2 129 P2 123 P2 112 P2 112 P2 126 P2 119 P2 123 P2 I11 P2 123 P2 109 P2 118 P2 108 P2 103 P2 119 P2 121 P2 123 P2 114 P2 131 P2 116 P2 71 P2 82 P2 95 P2 92 P2 97 P2 105 P2 55 P2 78 P2 55 P2 99 P2 107 P2 58 P2 101 P2 61 P2 78 P2 124 P2 142 P2 126 P2 88 P2 104 P2 107 P2 114 P2 133 P2 118 P2 92 P2 154 P2 138 P2 101 P2 100 P2 139 P2 132 P2 130 P2 IND %TW TWD 15 TWD 13 TWD 16 TWD 4 TWD 8 TWD 8 TWD 6 TWD 13 TWD 7 TWD 17 TWD 9 TWO 11 TWD 9 TWD 6 TWD 12 TWO 7 TWD 18 TWD 8 TWD 12 TWD 8 TWD 8 TWD 5 TWD 6 TWD 8 TWD 7 TWD 4 TWD 18 TWD 19 TWD 16 TWD 6 TWD 16 TWD 10 TWD 7 TWD 6 TWD 17 TWD 17 TWD 11 TWD 8 TWD 11 TWD 7 TWD 5 TWD 8 TWD 17 TWD 19 TWD 14 TWD 13 TWD 6 TWD 17 TWD 4 TWD 8 TWD 14 TWD 5 TWD 10 TWD 13 TWD 6 TWD 7 TWD 6 TWD 9 TWD 15 TWD 6 TWD 11 TWD 8 TWD 10 TWD 10 TWD 6 TWD 6 TWD 5 TWD 7 TWO 7 TWD 12 TWD 5 TWD 7 TWD 9 TWD 4 TWD 6 TWD 7 TWD 6 TWD 4 TWD 6 TWD 8 LOCATIO AV5 AV6 AV7 AV8 AV3 AV4 AV5 AV6 AV7 AV4 AV5 AV6 AV7 AV2 AV3 AV7 AV6 AV3 AV6 AV5 AV4 AV2 AV7 AV6 AV3 AV8 AV5 AV4 AV3 AV2 AV4 AV3 AV2 AV7 AV6 AV5 AV4 AV3 AV2 AV8 AV7 AV6 AV5 AV4 AV3 AV2 AVI AV7 AV4 AV3 AV2 AV6 AV5 AV6 AV4 AV3 AV8 AV7 AV3 AV2 AV1 AV6 AV5 AV3 AV4 AV6 AV5 AV7 AV6 AV5 AV5 AV3 AV5 AV4 AV3 AV5 AV7 AV5 AVI AV4 N

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

-0.18

-0.24

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

.+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

-0.20

-0.26

-0.18

-0.26

-0.09

-0.02

-0.04

+0.07

+0.13

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

-0.22

+0.00

+0.00

+0.24

+0.18

+0.00

+0.00

+0.00

+0.00

-0.28

-0.09

+0.22

+0.00

+0.00 EXT EXT TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEN TEC TEN TEC UTIL 1

UTIL 2

- --- -= = =

CAL #

18 18 18 18 11 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 20 20 20 20 20 20 20 20 20 20 20 30 20 20 30 30 30 30 30 30 30 29 29 29 29 29 29 29 29 28 27 27 27 27 27 20 20 5

6 54 54 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD NOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD PROBE 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 6100L 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 6 10UDL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:34 Component: S/G A Page 29 of 73 Component: S/C A Page 29 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 29 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 81 26 0.11 81 36 0.24 0.14 81 46 0.17 81 50 0.18 81 52 0.12 81 62 0.15 0.15 0.33 0.13 81 64 0.16 81 66 0.13 0.14 81 70 0.32 0.25 0.19 0.28 0.23 81 72 0.47 0.31 0.27 0.59 0.51 81 74 0.12 0.22 0.48 0.35 0.38 81 76 0.30 0.20 0.10 81 78 0.30 0.59 0.42 0.23 81 80 0.18 0.21 0.17 81 82 0.28 0.57 0.56 0.71 0.70 81 84 0.16 0.14 0.24 81 86 0.19 0.15 0.35 81 88 0.38 0.30 0.25 81 90 0.17 0.45 0.12 0.53 0.21 81 92 0.40 0.44 0.32 0.59 0.40 0.10 81 94 0.25 0.25 0.56 0.63 0.45 0.21 0.15 81 96 0.15 0.28 0.43 0.26 0.18 81 98 0.60 0.33 81 100 0.18 0.27 0.12 DEG CHN IND 138 P2 TWD 120 P2 TWD 112 P2 TWD 137 P2 TWD 99 P2 TWD 103 P2 TWD 139 P2 TWD 134 P2 TWD 126 P2 TWD 132 P2 TWD 134 P2 TWD 146 P2 TWD 147 P2 TWD 124 P2 TWD 118 P2 TWD 133 P2 TWD 128 P2 TWD 121 P2 TWD 122 P2 TWD 133 P2 TWD 134 P2 TWD 122 P2 TWD 122 P2 TWD 150 P2 TWD 137 P2 TWD 123 P2 TWD 128 P2 TWD 130 P2 TWD 133 P2 TWD 134 P2 TWD 139 P2 TWD 116 P2 TWD 126 P2 TWD 128 P2 TWD 127 P2 TWD 114 P2 TWD 139 P2 TWD 124 P2 TWD 124 P2 TWD 124 P2 TWD 117 P2 TWD 116 P2 TWD 123 P2 TWD 118 P2 TWD 124 P2 TWD 117 P2 TWD 117 P2 TWD Ill P2 TWD 120 P2 TWD 109 P2 TWD 113 P2 TWD 117 P2 TWD 121 P2 TWD 116 P2 TWD 128 P2 TWD 115 P2 TWD 75 P2 TWD 119 P2 TWD 116 P2 TWD 110 P2 TWD 122 P2 TWD 109 P2 TWD 108 P2 TWD 115 P2 TWD 122 P2 TWD 121 P2 TWD 118 P2 TWD 117 P2 TWD 109 P2 TWD 118 P2 TWD 121 P2 TWD 117 P2 TWD 117 P2 TWD 126 P2 TWD 111 P2 TWD 121 P2 TWD 110 P2 TWD 140 P2 TWD 125 P2 TWD 133 P2 TWD

%TW LOCATIOb 5

AV5 8

AV4 5

AV5 6

AV4 7

AV4 5

AV4 6

AV2 6

AV3 11 AV5 5

AV6 6

AV3 5

AV5 5

AV6 11 AV3 9

AV4 7

AV5 10 AV6 8

AV7 15 AV2 11 AV3 9

AV4 17 AV5 16 AV7 5

AV7 8

AV2 15 AV4 12 AV5 13 AV6 11 AV3 8

AV7 4

AV6 10 AV3 18 AV5 14 AV6 8

AV7 6

AV5 7

AV6 6

AV7 9

AV2 16 AV3 16 AV5 18 AV6 18 AV7 5

AVI 5

AV5 8

AV6 7

AV3 6

AV5 12 AV7 13 AV5 10 AV6 9

AV7 6

AV6 15 AV5 5

AV4 16 AV3 8

AV2 13 AV6 14 AV5 11 AV4 17 AV3 13 AV2 4

AVl 9

AV7 9

AV6 17 AV5 18 AV4 15 AV3 8

AV2 6

AVI 6

AV7 10 AV5 14 AV4 9

AV3 7

AV2 18 AV6 12 AV2 7

AV7 10 AV6 5

AV5

+0.00

+0.22

-0.13

+0.04

+0.22

+0.20

+0.00

+0.07

+0.13

+0.00

+0.00

+0.04

+0.13

+0.04

+0.09

+0.02

+0.11

+0.07

+0.07

+0.15

+0.11

+0.13

+0.02

+0.11

+0.07

+0.09

+0.17

+0.11

+0.13

+0.11

+0.11

+0.02

+0.09

+0.09

+0.07

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

-0.09

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00 EXT TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEN TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC EXT TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH UTIL 1

UTIL 2

CAL 55 21 21 19 19 17 15 15 15 15 15 15 15 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 11 1B 18 18 1B 18 18 18 1B 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 20 20 20 20 20

  1. LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UDL 610UL 610UL 610TUL 610UL 610UDL 610TDL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:34 Component: S/G A Page 30 of 73 Component: S/C A Page 30 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 30 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.35 0.23 0.21 0.09 81 102 0.15 0.20 81 104 0.39 0.39 0.41 0.49 0.22 81 106 0.25 0.20 0.29 0.49 0.40 0.17 81 108 0.18 81 110 0.11 0.16 0.18 81 112 0.17 0.12 81 114 0.11 0.09 81 116 0.11 0.14 81 122 0.15 81 128 0.13 0.10 81 130 0.14 81 132 0.11 0.20 81 134 0.13 0.13 81 138 0.15 0.09 81 146 0.09 81 150 0.14 82 25 0.12 82 45 0.18 82 55 0.14 82 67 0.38 0.30 0.33 0.37 0.30 82 69 0.23 0.31 0.18 82 71 0.16 0.28 0.18 82 73 0.52 0.55 0.39 0.49 0.13 82 75 0.44 0.14 82 77 0.13 0.32 0.16 0.34 0.58 82 79 0.29 0.59 0.34 0.22 0.17 0.11 82 81 0.14 0.30 0.23 0.32 0.13 0.42 82 83 0.18 0.19 0.58 DEG 127 130 131 157 127 112 95 87 106 93 75 104 96 97 107 106 133 75 49 100 99 100 137 99 93 83 90 74 55 97 79 103 83 77 88 83 132 151 126 136 115 128 121 125 ill 108 ill 117 94 ill 124 100 112 122 117 123 113 117 122 119 116 113 105 121 109 122 121 116 135 120 137 107 113 131 118 74 116 128 129 124 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWD 12 TWD 9 TWD 8 TWD 4 TWD 6 TWD 8 TWD 13 TWD 13 TWD 13 TWD 15 TWD 8 TWD 9 TWD 7 TWD 10 TWD 15 TWD 13 TWD 6 TWD 8 TWD 5 TWD 7 TWD 8 TWD 8 TWD 6 TWD 5 TWD 5 TWD 5 TWD 7 TWD 8 TWD 8 TWD 6 TWD 8 TWD 7 TWD 11 TWD 8 TWD 8 TWD 7 TWD 5 TWD 4 TWD 6 TWD 5 TWD 7 TWD 6 TWD 13 TWD 11 TWD 12 TWD 13 TWD 11 TWD 9 TWD 11 TWD 7 TWD 6 TWD 10 TWD 7 TWD 16 TWD 17 TWD 13 TWD 15 TWD 5 TWD 14 TWD 6 TWD 5 TWD 11 TWD 6 TWD 12 TWD 17 TWD 10 TWD 18 TWD 12 TWD 8 TWD 6 TWD 4 TWD 6 TWD 11 TWD 9 TWD 11 TWD 5 TWD 14 TWD 7 TWD 7 TWD 18 LOCATION AV4

+0.00 AV3

+0.00 AV2

+0.00 AVI

+0.00 AV7

+0.00 AV5

+0.00 AV7

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AVI

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV7

+0.00 AV2

+0.00 AV7

+0.00 AV5

+0.00 AV3

+0.00 AV6

+0.07 AV2

-0.22 AV6

+0.15 AV5

+0.00 AV6

+0.15 AV5

+0.13 AV3

+0.00 AV5

-0.26 AV3

+0.00 AV5

-0.22 AV7

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV5

+0.00 AV3

+0.00 AV4

+0.09 AVI

-0.33 AV3

+0.00 AV4

+0.13 AV4

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV4

+0.00 AV5

+0.00 AV7

+0.31 AVi

+0.00 AV6

+0.29 AV7

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV7

-0.24 AV8

+0.00 AV6

+0.00 AV7

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV8

+0.00 AV2

+0.00 AV4

+0.31 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV8

+0.00 AV2

+0.00 AV3

+0.00 AV4

-0.19 AV5

+0.00 AV6

+0.00 AV7

-0.22 AV2

+0.00 AV3

+0.30 AV4

+0.00 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC UTIL 1

UTIL 2

CAL #

20 20 20 20 20 20 30 30 30 30 30 30 30 30 30 30 30 29 29 29 29 27 27 27 27 27 27 25 21 21 21 21 21 21 21 19 19 6

4 55 19 18 16 16 16 16 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 12 12 12 12 12 12 12 12 12 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl 12/14/12 11:34:34 Component: S/G A Page 31 of 73, Enc. 2 Page 31 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.63 0.46 0.52 82 85 0.11 0.13 0.54 0.44 82 87 0.14 0.12 0.16 82 89 0.24 0.48 82 91 0.29 0.41 0.43 0.12 82 93 0.51 0.18 0.17 0.12 82 95 0.54 0.36 0.36 0.17 82 97 0.44 0.09 82 99 0.19 0.38 0.41 0.29 0.33 82 101 0.40 0.41 0.11 82 103 0.49 0.36 82 105 0.13 0.44 82 107 0.22 82 109 0.18 0.15 0.14 0.10 82 111 0.25 82 115 0.16 0.12 82 117 0.13 0.28 0.31 0.16 0.10 82 127 0.11 0.12 0.18 0.17 82 133 0.21 0.16 0.19 82 135 0.10 0.11 0.10 82 139 0.14 0.10 83 20 0.12 83 26 0.14 83 36 0.22 83 38 0.17 83 40 0.18 83 46 0.16 83 50 0.31 83 64 0.20 0.27 83 66 0.24 83 68 0.19 0.51 0.30 83 70 0.30 0.11 0.18 0.21 DEG 121 128 123 131 120 120 115 90 117 63 112 113 88 105 102 66 113 132 112 119 110 113 103 96 109 127 106 100 104 114 109 108 107 55 125 117 135 125 126 73 51 63 61 99 147 121 142 137 117 142 127 152 149 139 145 132 130 121 74 50 52 106 75 72 133 102 145 145 141 104 127 107 116 115 115 116 114 143 113 115 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW 19 15 17 5

5 17 15 7

6 7

10 18 12 16 16 6

18 8

8 6

19 14 14 8

17 5

9 15 16 13 14 16 16 6

16 13 5

15 9

8 7

7 5

11 6

5 5

10 11 6

4 5

5 7

7 8

7 8

6 7

6 7

5 5

6 8

7 7

6 10 8

10 9

8 17 11 11 4

7 8

LOCATION AV5

+0.00 AV6

+0.00 AV7

-0.15 AV2

+0.24 AV3

+0.29 AV4

-0.18 AV7

-0.15 AV6

+0.00 AV5

+0.00 AV3

+0.00 AV6

+0.00 AV5

+0.00 AV7

+0.00 AV6

+0.00 AV5

-0.11 AV2

-0.20 AV5

+0.00 AV3

+0.00 AV2

+0.00 AVl

+0.00 AV7

+0.00 AV3

+0.00 AV2

+0.00 AV1

+0.00 AV2

+0.00 AVI

+0.00 AV8

+0.00 AV7

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV6

+0.00 AV3

+0.00 AV2

+0.00 AV7

+0.00 AV8

+0.00 AVI

+0.00 AV2

+0.00 AV6

+0.00 AV8

+0.00 AV2

+0.00 AV7

-0.09 AVl

-0.07 AV6

+0.00 AV6

+0.00 AV5

-0.18 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV5

-0.20 AV4

+0.00 AV3

+0.00 AV8

+0.00 AV4

+0.00 AV2

+0.00 AV4

+0.00 AV5

+0.00 AVI

-0.11 AV3

+0.00 AV4

+0.22 AV5

+0.00 AV5

+0.02 AV4

+0.18 AV4

+0.24 AV5

+0.00 AV6

+0.00 AV4

+0.00 AV5

+0.00 AV6

-0.04 AV7

+0.00 AVl

-0.16 AV2

+0.00 AV3

+0.00 AV5

+0.33 EXT EXT UTIL 1

UTIL 2

TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH.*

TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEE TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC CAL 12 12 12 12 12 12 12 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 19 19 19 19 19 19 19 19 19 19 31 31 31 31 31 29 29 29 29 29 28 28 28 28 28 28 28 24 24 24 24 22 22 22 21 21 21 19 19 55 54 22 22 22 20 20 16 16 16 16 16 16 14 14 14 14

  1. LEG COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UDL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:34 Component: S/G A Page 32 of 73 Component: S/C A Page 32 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 32 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.25 0.16 83 72 0.20 0.36 0.32 0.64 0.67 0.30 83 74 0.40 0.15 0.38 0.34 0.25 83 76 0.15 0.33 0.44 83 78 0.13 0.38 0.38 0.26 83 80 0.38 0.35 0.66 0.28 0.16 83 82 0.26 0.10 0.12 0.36 83 84 0.12 0.50 0.40 0.50 0.21 0.36 83 86 0.52 0.53 0.14 0.22 83 88 0.20 83 90 0.20 0.27 0.50 0.16 83 92 0.28 0.43 0.23 83 94 0.24 0.34 0.41 0.33 0.13 83 96 0.15 0.35 0.20 83 98 0.37 0.15 0.21 0.50 83 100 0.38 0.14 0.25 0.19 83 102 0.18 0.48 0.35 83 104 0.10 0.37 0.21 0.57 0.07 83 106 0.20 0.22 0.46 0.11 83 108 0.38 0.39 0.34 83 110 0.12 0.28 DEG CHN 117 P2 124 P2 125 P2 123 P2 117 P2 116 P2 118 P2 120 P2 124 P2 112 P2 122 P2 128 P2 126 P2 125 P2 111 P2 109 P2 141 P2 114 P2 124 P2 121 P2 124 P2 129 P2 115 P2 133 P2 119 P2 118 P2 129 P2 130 P2 121 P2 129 P2 121 P2 124 P2 118 P2 130 P2 113 P2 99 P2 101 P2 103 P2 90 P2 58 P2 105 P2 104 P2 104 P2 100 P2 107 P2 114 P2 151 P2 113 P2 96 P2 110 P2 94 P2 117 P2 92 P2 103 P2 71 P2 116 P2 102 P2 104 P2 110 P2 105 P2 50 P2 111 P2 99 P2 78 P2 112 P2 104 P2 113 P2 125 P2 134 P2 123 P2 152 P2 138 P2 131 P2 129 P2 134 P2 113 P2 109 P2 119 P2 105 P2 107 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW 9

6 8

12 11 19 19 11 13 6

13 12 9

6 11 14 5

13 13 9

13 12 19 11 6

10 4

5 13 5

16 14 16 8

13 18 19 7

10 9

9 12 18 8

12 16 10 11 14 16 13 6

7 14 9

15 8

10 19 16 7

11 9

9 18 15 4

13 8

18 3

8 9

15 5

14 15 13 6

12 LOCATION AV6

+0.00 AV7

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV6

-0.15 AV7

+0.31 AV8

+0.35 AV3

+0.31 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AVl

+0.00 AV2

+0.37 AV4

+0.00 AV2

+0.00 AV3

+0.00 AV6

+0.00 AV7

+0.00 AV4

+0.00 AV5

+0.00 AV6

-0.15 AV7

-0.15 AV8

+0.00 AV3

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.33 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.31 AV7

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV3

+0.00 AV8

-0.07 AV4

-0.07 AV2

-0.09 AVI

-0.11 AV2

-0.09 AV4

+0.02 AV8

-0.11 AV8

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AVM

+0.00 AV7

+0.00 AV5

+0.00 AV2

+0.00 AV2

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AVI

+0.00 AV7

+0.00 AV3

+0.00 AV2

+0.00 AVI

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV7

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV3

+0.00 AV5

+0.20 AV4

+0.00 AV3

+0.00 AV6

+0.00 AV5

+0.00 EXT EXT UTIL 1

UTIL TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH 2

CAL #

14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 19 19 19 19 19 19 19 19 19 19 19 31 31 31 31 31 31 31 31 31 29 29 29 29 29 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610DL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 6100L 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 6100L 610UL 610UL 610UL 610UL 610UL 6100L 610UL 610UL 61DOL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:34 Component: S/G A Page 33 of 73 Component: S/C A Page 33 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 33 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.13 83 112 0.11 83 116 0.16 83 124 0.15 0.14 83 132 0.15 0.15 83 134 0.15 83 140 0.16 0.15 0.17 83 146 0.15 83 150 0.25 84 35 0.13 0.19 84 45 0.28 84 47 0.14 84 63 0.36 0.13 84 65 0.12 0.09 84 67 0.20 0.23 84 69 0.51 0.51 0.20 84 71 0.13 0.45 84 73 0.28 0.30 0.20 0.27 0.12 84 75 0.33 0.48 0.27 0.15 0.10 84 77 0.58 0.61 0.57 0.13 84 79 0.42 0.19 0.42 0.54 84 81 0.23 0.38 84 83 0.11 0.32 0.09 0.28 0.31 0.15 84 85 0.67 0.50 84 87 0.15 0.58 0.68 0.22 84 89 0.23 0.57 0.35 84 91 0.42 0.66 84 93 0.42 0.39 0.48 0.20 84 95 0.21 0.39 0.60 0.54 0.16 84 97 0.45 0.42 0.55 0.14 0.30 84 99 0.47 DEG 49 110 136 144 141 144 122 143 126 114 99 108 97 140 145 116 112 122 134 135 144 123 135 120 132 123 147 129 127 128 136 131 143 121 122 124 122 137 118 118 119 138 127 128 124 118 129 128 95 124 68 118 130 129 124 119 93 125 118 123 117 127 128 117 115 ill 112 115 89 124 126 115 114 128 116 124 121 117 ill 120 CHN IND P2 TWD P2 TWD P2 TWD P2 TWO P2 TWO P2 TWD P2 TWO P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWO P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWO P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWO P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD

%TW LOCATIO 6

AV4 5

AV6 6

AV2 7

AV5 6

AV4 6

AV7 6

AV5 6

AV4 8

AV8 7

AV6 8

AV4 7

AV8 10 AVI 5

AV3 7

AV5 10 AV4 5

AV4 12 AV2 5

AV5 5

AV5 4

AVI 7

AV4 8

AV5 15 AV4 15 AV5 7

AV6 5

AV2 14 AV5 10 AV3 11 AV4 8

AV5 10 AV6 5

AV7 11 AV2 15 AV4 10 AV5 6

AV6 4

AVi 17 AV3 18 AV4 17 AV8 5

AV2 14 AV3 7

AV4 14 AV5 17 AV6 8

AV4 12 AV6 4

AVI 10 AV2 3

AV4 9

AV5 10 AV6 5

AV7 18 AV5 14 AV7 6

AV2 17 AV5 19 AV6 8

AV7 8

AV7 17 AV6 12 AV2 14 AV6 19 AV5 14 AV8 13 AV3 15 AV2 8

AVI 8

AV6 13 AV5 18 AV4 16 AV3 6

AVl 15 AV7 14 AV6 17 AV4 6

AV3 11 AV2 15 AV7

+0.00

+0.00

+0.00

+0.0002

+0.00

+0.00

-0.24

+0.00

-0.02

-0.09

-0.09

-0.16

+0.00

+0.00

+0.00

+0.28

+0.20

+0.00

+0.09

+0.00

+0.07

+0.00

+0.09

+0.07

+0.20

+0.13

+0.00

+0.07

+0.00

+0.11

+0.04

+0.11

+0.20

+0.09

+0.09

+0.13

+0.09

+0.04

+0.07

+0.04

+0.09

+0.00

+0.33

+0.00

+0.29

-0.18

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00 EXT EXT UTIL 1

UTIL 2

TEC TEN TEC TEH TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEN TEC TEH TEC TEN TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC TEN TEC TEN TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEC TEN TEC TEN TEC TEH TEC TEH TEC TEN TEC TEN TEC TEN TEC TEH TEC TEH TEC TEH TEC TEN TEC TEN TEC TEH TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEE CAL # LEG 29 HOT 28 HOT 28 HOT 26 HOT 26 HOT 22 HOT 22 HOT 22 HOT 7

HOT 7

HOT 7

HOT 5

HOT 3

HOT 24 COLD 24 COLD 20 COLD 20 COLD 15 COLD 15 COLD 15 COLD 15 COLD 15 COLD 15 COLD 15 COLD 15 COLD 15 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 14 COLD 14 COLD 14 COLD 14 COLD 11 COLD 11 COLD 11 COLD 11 COLD 11 COLD 11 COLD 11 COLD 11 COLD 11 COLD 11 COLD 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 20 HOT 20 HOT 20 HOT 20 HOT 20 HOT 20 HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610DL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 6100L 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610DL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:34 Component: S/G A Page 34 of 73 Component: S/C A Page 34 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 34 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.45 0.19 84 101 0.26 0.30 0.37 0.15 84 103 0.60 0.29 0.62 0.28 84 105 0.25 0.58 0.20 0.15 84 107 0.55 0.31 0.64 0.62 0.16 84 109 0.17 0.22 0.34 0.32 84 ill 0.18 0.29 0.12 0.36 0.27 84 113 0.17 0.07 84 115 0.27 0.53 0.34 0.25 84 117 0.12 0.15 0.24 0.46 0.49 0.35 0.27 0.11 84 125 0.18 84 131 0.13 84 133 0.10 84 137 0.13 85 36 0.13 85 56 0.17 0.15 85 66 0.10 85 68 0.26 0.13 0.12 0.50 85 70 0.38 0.27 0.30 0.39 0.37 85 72 0.19 0.22 0.26 85 74 0.55 0.12 0.43 85 76 0.46 0.29 0.60 85 78 0.16 0.55 0.27 0.29 0.35 85 80 0.29 0.52 0.21 0.15 85 82 0.51 0.32 0.48 DEG CHN 116 P2 134 P2 119 P2 120 P2 112 P2 128 P2 109 P2 116 P2 103 P2 101 P2 96 P2 107 P2 90 P2 72 P2 101 P2 87 P2 99 P2 99 P2 73 P2 84 P2 102 P2 100 P2 100 P2 87 P2 95 P2 66 P2 102 P2 92 P2 140 P2 139 P2 121 P2 113 P2 110 P2 115 P2 117 P2 117 P2 113 P2 120 P2 119 P2 113 P2 116 P2 79 P2 134 P2 63 P2 78 P2 123 P2 127 P2 116 P2 142 P2 147 P2 131 P2 148 P2 141 P2 126 P2 126 P2 123 P2 122 P2 127 P2 132 P2 131 P2 128 P2 124 P2 123 P2 129 P2 122 P2 125 P2 131 P2 118 P2 121 P2 125 P2 131 P2 131 P2 132 P2 126 P2 119 P2 132 P2 128 P2 119 P2 130 P2 120 P2 IND %TW TWD 15 TWD 7 TWD 10 TWD 11 TWD 13 TWD 6 TWD 17 TWD 10 TWD 18 TWD 10 TWD 9 TWD 17 TWD 7 TWD 6 TWD 16 TWD 11 TWD 18 TWD 18 TWD 6 TWD 8 TWD 10 TWD 13 TWD 13 TWD 8 TWD 12 TWD 6 TWD 14 TWD 11 TWD 7 TWD 3 TWD 12 TWD 19 TWD 14 TWD 11 TWD 6 TWD 7 TWD 11 TWD 17 TWD 18 TWD 14 TWD 12 TWD 5 TWD 8 TWD 8 TWD 6 TWD 5 TWD 5 TWD 6 TWD 5 TWD 4 TWD 9 TWD 5 TWD 5 TWD 15 TWD 13 TWD 9 TWD 10 TWD 13 TWD 12 TWO 7 TWD 8 TWD 9 TWD 17 TWD 5 TWD 14 TWD 15 TWD 10 TWD 18 TWD 6 TWD 17 TWD 10 TWD 10 TWD 12 TWD 9 TWD 15 TWD 7 TWD 5 TWD 14 TWD 10 TWD 14 LOCATION AV3

+0.00 AV3

+0.00 AV7

+0.00 AVS

+0.00 AV4

+0.00 AV3

+0.00 AV6

+0.00 AVS

+0.00 AV4

+0.00 AV4

+0.00 AV6

+0.00 AV6

+0.00 AV2

+0.00 AV2

+0.00 AV7

+0.00 AVS

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV2

+0.13 AV4

+0.00 AV2

+0.00 AV2

+0.00 AV6

+0.00 AVS

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV5

+0.11 AV2

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV8

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV2

+0.00 AV2

+0.00 AV5

+0.00 AV3

+0.00 AV5

+0.00 AV4

+0.22 AV4

+0.13 AV7

+0.09 AV6

+0.18 AV3

+0.00 AV5

+0.02 AV6

+0.09 AV7

+0.04 AV3

+0.11 AV4

+0.09 AV5

+0.13 AV6

+0.02 AV7

+0.09 AV2

+0.04 AV6

+0.15 AV7

+0.00 AV2

+0.04 AV6

+0.17 AV7

+0.04 AV3

+0.02 AV4

+0.04 AV7

-0.04 AV3

+0.07 AV4

+0.07 AV5

+0.11 AV6

+0.04 AV7

+0.15 AV4

+0.00 AV6

+0.00 AV7

+0.00 AV5

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC UTIL 1 UTIL 2

CAL # LEG 20 HOT 20 HOT 20 HOT 20 HOT 20 HOT 20 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 29 HOT 29 HOT 29 HOT 29 HOT 29 HOT 29 HOT 29 HOT 29 HOT 29 HOT 28 HOT 28 HOT 27 HOT 27 HOT 27 HOT 27 HOT 27 HOT 27 HOT 27 HOT 27 HOT 27 HOT 27 HOT 27 HOT 27 HOT 26 HOT 21 HOT 21 HOT 20 HOT 21 COLD 17 COLD 17 COLD 15 COLD 15 COLD 15 COLD 15 COLD 15 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 11 COLD 11 COLD 11 COLD 11 COLD 11 COLD 11 COLD 11 COLD PROBE 61OUL 610UL 610UL 61OUL 61OUL 61OUL 610UL 610UL 610UL 610DL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 610TUL 610UDL 610TUL 610TUL 610UL 610UL 610UL 610UL 610TDL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610DL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610TUL 610UL 610UL 610DL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:34 Component: S/G A Page 35 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl Aftachment 1, Enc. 2 Page 35 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.50 0.67 85 84 0.40 0.55 0.47 0.75 85 86 0.17 0.38 0.56 85 88 0.18 0.13 0.63 0.13 0.31 85 90 0.24 0.37 0.18 0.25 85 92 0.12 0.29 0.70 0.48 0.14 85 94 0.22 0.25 0.27 0.31 0.17 0.14 85 96 0.13 0.36 0.46 0.22 0.38 0.14 85 98 0.30 0.44 85 100 0.12 0.22 0.52 0.31 0.59 0.16 85 102 0.43 0.17 0.45 0.23 0.41 85 104 0.19 0.56 0.17 85 106 0.30 0.52 0.50 85 108 0.17 0.24 0.32 0.26 0.15 85 110 0.18 0.24 0.16 0.26 85 112 0.10 0.11 0.31 0.13 85 114 0.14 0.25 85 116 0.17 0.10 85 118 0.17 85 124 0.15 85 130 0.19 85 132 0.11 0.13 85 134 0.14 0.13 86 45 0.13 0.14 DEG 126 120 119 124 124 115 127 124 121 87 106 116 127 120 128 121 100 115 92 118 ill 116 122 115 115 136 114 87 108 86 120 112 130 116 135 120 120 139 114 122 106 118 135 127 120 121 123 123 52 98 68 104 99 103 83 102 97 110 88 103 104 113 94 108 72 117 97 122 128 121 95 124 83 84 72 76 64 74 80 118 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWD 14 TWD 18 TWD 12 TWD 15 TWD 14 TWD 19 TWD 6 TWD 13 TWD 17 TWD 7 TWD 5 TWD 18 TWD 5 TWD 11 TWD 9 TWD 13 TWD 7 TWD 9 TWD 5 TWD 10 TWD 19 TWD 15 TWD 5 TWD 8 TWD 9 TWD 10 TWD 11 TWD 7 TWD 5 TWD 5 TWD 12 TWD 15 TWD 8 TWD 13 TWD 6 TWD 11 TWD 15 TWD 5 TWD 8 TWD 17 TWD 11 TWD 18 TWD 6 TWD 14 TWD 7 TWD 15 TWD 9 TWD 14 TWD 7 TWD 17 TWD 6 TWD 10 TWD 16 TWD 15 TWD 8 TWD 10 TWD 13 TWD 11 TWD 7 TWD 8 TWD 10 TWD 7 TWD 11 TWD 5 TWD 6 TWD 13 TWD 6 TWD 7 TWD 11 TWD 8 TWD 5 TWD 9 TWD 8 TWD 11 TWO 7 TWD 8 TWD 8 TWD 8 TWD 5 TWD 5 LOCATION AV6

+0.00 AV7

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV7

+0.00 AV2

+0.00 AV4

+0.00 AV5

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV6

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV3

+0.00 AV2

+0.00 AV8

+0.00 AV6

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV8

+0.00 AV7

+0.00 AV6

+0.00 AV3

+0.00 AV2

+0.00 AVI

+0.00 AV8

+0.00 AV7

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV6

+0.00 AV5

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV2

+0.00 AV7

+0.00 AV2

+0.00 AVI

+0.00 AV7

+0.00 AV4

+0.00 AV2

+0.00 AV5

+0.15 AV4

+0.00 AV3

+0.00 AV2

+0.11 AVI

+0.00 AV6

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV5

+0.02 AV4

-0.15 AV2

+0.00 AVl

+0.11 AV6

+0.15 AV3

+0.00 AV6

+0.00 AV5

+0.20 AV5

+0.00 AV4

+0.00 AV6

+0.00 AV4

+0.00 AV3

+0.00 AV8

+0.00 AV4

+0.00 AV4

+0.22 AV5

-0.09 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH

  • TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC UTIL 1

UTIL 2

CAL 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 20 20 20 20 20 20 20 20 20 20 20 20 20 30 30 30 30 30 30 29 29 29 29 29 29 29 29 29 27 27 27 27 27 27 27 27 25 25 21 21 21 21 21 19 19

  1. LEG COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:34 Component: S/G A Page 36 of 73 Bobbin AVB Wear Indications 1% to 19%

Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 36 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 86 63 0.16 86 69 0.25 0.40 0.49 0.21 86 71 0.68 0.53 86 73 0.29 0.34 0.61 0.56 86 75 0.20 0.46 0.60 0.41 86 77 0.31 0.50 86 79 0.20 0.58 86 81 0.10 0.34 0.48 0.54 0.22 0.17 86 83 0.27 0.27 0.47 0.33 0.44 0.16 86 85 0.20 0.39 0.46 86 87 0.12 0.23 0.55 86 89 0.26 0.49 0.37 86 91 0.13 0.15 0.15 0.09 86 93 0.30 86 95 0.21 0.20 86 97 0.12 0.16 0.40 0.17 86 99 0.16 0.51 0.20 0.12 0.27 0.20 86 101 0.23 0.31 0.28 0.14 86 103 0.46 0.14 0.17 0.17 86 105 0.21 0.19 0.19 0.34 86 109 0.11 0.37 0.32 86 113 0.11 0.24 86 117 0.12 0.16 0.21 86 121 0.13 86 125 0.16 86 129 0.15 DEG 137 104 118 108 119 118 126 129 117 114 117 129 129 118 122 124 116 132 118 143 126 121 121 137 126 131 134 127 116 119 100 119 108 108 57 99 110 91 108 109 114 135 112 140 110 113 93 80 99 106 67 112 112 108 74 90 109 84 94 119 109 121 146 131 133 119 128 140 129 121 99 109 69 126 151 129 134 129 88 90 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW 7

10 14 16 8

19 16 10 12 18 17 8

15 18 14 11 16 7

17 4

12 16 17 9

7 10 10 15 12 15 6

8 14 15 6

10 19 11 18 15 6

7 7

5 12 9

9 6

8 16 8

8 19 9

6 12 9

11 13 13 7

15 6

7 7

8 8

7 12 5

14 13 5

11 5

6 8

7 9

9 LOCATION AVl

+0.00 AV4

-0.24 AV5

+0.00 AV6

+0.35 AV7

+0.31 AV4

+0.00 AV7

+0.28 AV3

+0.00 AV4

+0.29 AV5

+0.00 AV7

+0.39 AVl

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV3

+0.35 AV4

+0.00 AV2

+0.13 AV3

+0.04 AV2

+0.00 AV3

+0.00 AV4

-0.19 AV6

+0.00 AV7

-0.19 AV8

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.30 AV6

+0.00 AV7

-0.17 AV2

+0.29 AV3

+0.29 AV7

+0.09 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV7

+0.00 AV3

+0.00 AV2

+0.00 AV8

-0.07 AV7

+0.04 AV3

-0.07 AV2

+0.04 AV2

+0.00 AV6

+0.00 AVI

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV2

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

-0.04 AV2

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV3

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV7

+0.00 AV6

+0.00 AV4

+0.00 AV3

+0.00 AV4

-0.04 AV3

+0.22 AV7

+0.00 AV5

+0.00 AV4

+0.00 AV4

+0.00 AV2

+0.00 AV5

+0.00 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL #

16 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 13 13 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 17 17 17 17 17 17 17 17 17 17 17 17 17 19 19 19 19 19 19 19 19 19 19 19 19 19 19 31 31 31 31 31 31 31 31 29 29 29 27 27 28 28 28 25 25 21 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT NOT HOT HOT HOT NOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL

.610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610TUL 610UL 610UL 610UL 610TUL 610UL 610TDL 610DL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610TDL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl 12/14/12 11:34:34 Component: S/G A Page 37 of 73, Enc. 2 Page 37 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 86 135 0.18 0.13 86 139 0.10 86 147 0.15 87 36 0.14 87 42 0.15 87 44 0.18 87 46 0.20 87 52 0.11 0.11 87 54 0.12 0.12 0.11 87 64 0.21 0.17 0.16 0.14 87 66 0.24 87 70 0.19 0.24 0.39 0.29 0.24 87 72 0.12 0.22 0.30 0.65 0.13 0.31 0.18 87 74 0.26 0.25 0.57 87 76 0.15 0.18 0.15 0.32 0.12 0.34 0.14 87 78 0.15 0.26 0.33 0.12 87 80 0.19 0.23 0.54 0.27 87 82 0.14 0.51 0.49 87 84 0.14 0.34 0.47 87 86 0.17 0.50 0.36 87 88 0.14 87 90 0.13 0.49 0.37 0.37 0.21 87 92 0.42 0.45 87 94 0.26 0.36 0.24 87 96 0.15 0.36 0.38 0.15 87 98 0.34 87 100 0.50 0.16 0.12 0.20 87 102 0.31 0.13 87 104 0.63 DEG 94 77 135 86 107 152 134 147 102 135 141 130 72 117 124 117 129 100 126 128 114 127 123 116 130 127 120 148 129 114 119 127 116 99 123 147 131 124 117 124 99 118 119 142 138 130 121 104 117 118 123 108 117 119 98 115 109 120 88 94 100 94 107 108 114 108 109 105 81 104 96 83 84 114 68 63 100 109 126 121 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD TWD TWO TWD TWD TWD TWD TWD TWD TWD TWD TWO TWO TWO TWO TWO TWD TWO TWO TWO TWD TWO TWO TWD TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO TWD TWD TWD TWD TWD TWO TWD TWD TWD TWD TWD TWD TWO TWD TWD TWD TWD TWD TWO TWD TWO TWD TWO TWO TWO TWO TWO TWO TWO TWO TWO

%TW 10 8

5 7

6 6

7 7

5 5

5 5

5 8

7 7

6 9

7 9

13 10 9

5 8

11 19 5

11 7

10 9

17 6

76 5

12 6

6 10 12 5

7 9

17 10 6

16 16 6

12 15 8

18 14 7

6 18 15 15 9

16 17 11 14 10 7

14 15 7

14 19 8

6 9

13 7

19 LOCATION AV5 AV2 AV4 AV3 AV4 AV4 AV3 AV4 AV4 AV7 AV3 AV4 AV5 AV3 AV4 AV5 AV6 AV5 AV3 AV4 AV5 AV6 AV7 AVI AV3 AV4 AV5 AV6 AV7 AV8 AV3 AV4 AV5 AVI AV2 AV3 AV5 AV6 AV7 AV8 AV2 AV3 AV4 AV5 AV2 AV3 AV5 AV7 AV2 AV5 AV6 AV2 AV3 AV7 AV7 AV4 AV2 AV2 AV2 AV3 AV4 AV7 AV8 AV2 AV4 AV3 AV2 AVI AV6 AV5 AV2 AV1 AV2 AV2 AV1 AV7 AVS AV7 AV2 AV2

+0.00

+0.00

+0.00

+0.02

+0.00

+0.00

+0.09

+0.18

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.35

+0.00

+0.00

-0.16

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.35

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

-0.18

+0.00

+0.00

+0.00

+0.00

+0.26

-0.17

+0.00

+0.31

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEH UTIL 1

UTIL 2

CAL #

21 21 19 3

22 22 20 20 18 18 18 18 18 16 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 12 12 12 12 12 12 12 12 12 12 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 19 19 19 19 19 19 19 31 LEG HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 61OUL 61OUL 610UL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:35 Component: S/G A Page 38 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 38 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS DEG 0.17 127 87 106 0.28 133 0.19 143 0.08 156 87 108 0.19 87 0.17 71 87 110 0.11 68 0.13 88 87 112 0.20 140 87 114 0.22 131 0.26 127 87 116 0.12 128 0.15 122 0.07 151 87 118 0.12 125 87 120 0.12 152 0.11 147 87 126 0.11 158 87 132 0.15 143 87 148 0.12 72 0.13 73 88 45 0.12 107 88 63 0.14 149 0.14 120 0.12 140 88 65 0.14 146 88 67 0.12 128 0.15 126 88 69 0.12 150 0.27 132 0.28 117 88 71 0.13 128 0.24 134 0.16 146 0.31 132 0.19 120 0.63 124 0.64 118 88 73 0.58 117 0.28 i1 0.58 125 0.30 123 0.33 128 0.27 116 88 75 0.16 138 0.17 125 0.17 133 0.56 121 0.45 128 0.26 105 88 77 0.19 i1 0.22 121 0.45 130 0.35 126 0.31 130 0.53 119 0.35 127 0.51 120 88 79 0.25 129 0.13 108 88 81 0.67 119 0.54 123 0.77 122 0.51 121 88 83 0.47 113 0.27 118 0.20 127 0.15 132 0.24 130 88 85 0.16 95 0.35 123 0.13 116 0.32 123 88 87 0.16 100 0.62 116 0.43 116 0.33 122 0.66 113 0.21 119 88 89 0.24 124 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW LOCATION TWD 7 AV7

+0.00 TWD 11 AV2

+0.00 TWD 8 AV6

+0.00 TWD 4 AV7

+0.00 TWD 9 AV5

+0.00 TWD 8 AV2

+0.00 TWD 5 AV4

+0.00 TWD 6 AV2

+0.00 TWD 8 AV2

+0.00 TWD 8 AV7

+0.00 TWD 10 AV6

+0.00 TWD 5 AV6

+0.00 TWD 6 AV5

+0.00 TWD 3 AV2

+0.00 TWD 5 AV2

-0.20 TWD 6 AV6

+0.00 TWD 5 AV3

+0.00 TWD 5 AV3

+0.00 TWD 6 AV5

+0.00 TWD 6 AV8

+0.20 TWD 6 AVI

-0.27 TWD 5 AV4

+0.22 TWD 5 AV2

+0.00 TWD 5 AV6

+0.09 TWD 5 AV7

+0.15 TWD 5 AV2

+0.07 TWD 4 AV3

+0.00 TWD 6 AV5

+0.09 TWD 4 AV5

+0.07 TWD 9 AV6

+0.15 TWD 9 AV7

+0.09 TWD 5 AVl

+0.00 TWD 9 AV2

+0.07 TWD 6 AV3

+0.11 TWD 11 AV4

+0.11 TWD 7 AV5

+0.09 TWD 18 AV6

+0.07 TWD 18 AV7

+0.11 TWD 17 AV8

+0.09 TWD 10 AVI

+0.02 TWD 17 AV3

+0.04 TWD 10 AV4

+0.02 TWD 11 AV5

+0.04 TWD 9 AV6

+0.04 TWD 6 AV3

+0.09 TWD 6 AV4

+0.09 TWD 6 AV5

+0.07 TWD 17 AV6

+0.07 TWD 14 AV7

+0.07 TWD 9 AV8

+0.09 TWD 7 AVI

+0.07 TWD 8 AV2

+0.04 TWD 14 AV3

+0.09 TWD 12 AV4

+0.09 TWD 11 AV5

+0.09 TWD 16 AV6

+0.20 TWD 12 AV7

+0.04 TWD 16 AV8

+0.07 TWD 9 AV5

+0.28 TWD 5 AV7

+0.00 TWD 18 AV3

+0.00 TWD 15 AV4

+0.00 TWD 19 AV5

+0.00 TWD 14 AV6

+0.00 TWD 14 AV2

+0.00 TWD 9 AV4

+0.00 TWD 7 AV5

+0.00 TWD 5 AV6

+0.00 TWD 8 AV8

+0.00 TWD 6 AV3

+0.00 TWD 11 AV4

+0.00 TWD 5 AV5

+0.00 TWD 10 AV6

+0.00 TWD 6 AV2

+0.00 TWD 18 AV3

+0.00 TWD 14 AV4

+0.00 TWD 11 AV5

+0.00 TWD 19 AV6

+0.00 TWD 8 AV7

+0.00 TWD 9 AV7

+0.00 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL # LEG 31 HOT 31 HOT 31 HOT 31 HOT 29 HOT 29 HOT 29 HOT 29 HOT 28 HOT 28 HOT 28 HOT 28 HOT 28 HOT 28 HOT 26 HOT 26 HOT 26 HOT 24 HOT 22 HOT 3

HOT 3

HOT 20 COLD 15 COLD 15 COLD 15 COLD 15 COLD 15 COLD 15 COLD 15 COLD 15 COLD 15 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD 14 COLD 14 COLD 11 COLD 11 COLD 11 COLD 11 COLD 11 COLD 11 COLD 11 COLD 11 COLD 11 COLD 11 COLD 11 COLD 11 COLD 11 COLD 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT PROBE 61OUL 610UL 61OUL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 61OUL 61OUL 61OUL 61OUL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:35 Component: S/G A Page 39 of 73 Component: S/C A Page 39 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 39 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.67 0.24 0.45 88 91 0.22 0.18 0.30 0.33 0.12 0.10 88 93 0.23 0.35 0.43 88 95 0.14 0.46 0.31 88 97 0.15 0.19 0.18 0.11 88 99 0.23 0.49 0.50 0.19 88 101 0.25 0.12 0.39 0.18 0.08 88 103 0.37 0.60 88 105 0.34 0.17 0.29 0.26 88 107 0.28 0.15 0.17 0.34 88 109 0.19 0.27 88 113 0.15 88 115 0.20 88 117 0.14 0.13 0.21 0.27 88 121 0.14 88 123 0.16 88 133 0.11 88 147 0.13 89 50 0.12 0.15 89 54 0.14 89 70 0.18 89 72 0.37 0.52 0.44 0.64 0.14 0.13 89 74 0.20 0.20 89 76 0.15 0.15 0.30 0.25 89 78 0.26 0.58 0.54 0.10 89 80 0.31 0.15 0.14 89 82 0.22 0.37 0.67 0.33 0.41 89 84 0.34 0.20 DEG 120 112 115 112 119 120 120 111 112 123 128 138 ill 112 142 117 138 139 113 120 123 132 125 124 126 125 144 113 115 105 77 107 113 70 58 84 99 56 il 146 96 129 120 122 126 138 150 73 120 101 130 112 139 127 122 127 118 129 141 142 140 135 131 122 112 130 121 124 117 123 101 142 113 113 118 116 119 124 120 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWD 19 TWD 9 TWD 14 TWD 8 TWD 7 TWD 11 TWD 11 TWD 5 TWD 4 TWD 9 TWD 12 TWD 14 TWD 5 TWD 15 TWD 11 TWD 6 TWD 8 TWD 7 TWD 5 TWD 9 TWD 16 TWD 16 TWD 8 TWD 9 TWD 5 TWD 13 TWD 7 TWD 3 TWD 12 TWD 17 TWD 12 TWD 7 TWD 10 TWD 9 TWD 10 TWD 6 TWD 7 TWD 11 TWD 8 TWD 11 TWD 6 TWD 9 TWD 7 TWD 6 TWD 9 TWD 12 TWD 6 TWD 7 TWD 7 TWD 5 TWD 5 TWD 5 TWD 5 TWD 7 TWD 12 TWD 16 TWD 14 TWD 18 TWD 5 TWD 5 TWD 7 TWD 7 TWD 6 TWD 6 TWD 10 TWD 9 TWD 9 TWD 17 TWD 16 TWD 4 TWD 10 TWD 5 TWD 5 TWD 7 TWD 11 TWD 18 TWD 10 TWD 12 TWD 11 TWD 7 LOCATION AV6

+0.00 AV5

+0.00 AV4

+0.00 AV7

+0.00 AVS

+0.00 AV3

+0.00 AV2

+0.00 AVi

+0.00 AV8

-0.07 AV7

+0.00 AV5

+0.00 AV4

+0.00 AV7

+0.00 AV5

+0.00 AV2

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV2

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV6

+0.00 AV5

+0.00 AV2

+0.00 AVI

+0.00 AV7

+0.00 AV4

+0.00 AV2

+0.00 AV8

+0.00 AV6

+0.00 AV3

+0.00 AV2

+0.00 AV7

+0.07 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV4

+0.00 AV3

+0.00 AVl

-0.15 AV5

-0.20 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV3

+0.00 AV4

+0.00 AV3

+0.00 AV7

-0.26 AV4

+0.22 AV5

-0.07 AV4

+0.11 AV3

+0.09 AV2

+0.09 AV3

+0.07 AV4

+0.07 AV5

+0.09 AV6

-0.02 AV7

+0.07 AV6

+0.11 AV7

+0.11 AV2

+0.04 AV3

+0.11 AV4

+0.04 AV8

+0.04 AV3

+0.04 AV4

+0.02 AV5

+0.07 AV6

+0.29 AV7

+0.00 AV3

+0.02 AV6

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV7

+0.00 AV3

+0.00 AV4

+0.00 EXT EXT TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC UTIL 1

UTIL 2

CAL #

18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 20 20 20 20 20 20 20 20 20 20 20 20 20 30 30 30 30 30 30 30 30 30 30 29 29 28 27 27 27 27 27 26 26 21 4

19 19 17 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 11 11 11 11 11 11 11 11 11 11 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 61OUL 610UL 610UL 610OL 610UL 610OL 61OUL 610UL 61DUL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610OL 610OL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:35 Component: S/G A Page 40 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 40 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.51 0.44 89 86 0.14 0.63 89 88 0.14 0.14 0.25 89 90 0.24 0.62 0.58 89 92 0.24 0.50 0.18 0.30 0.42 89 94 0.17 0.53 0.43 0.14 0.15 0.16 89 96 0.18 0.13 0.14 0.61 89 98 0.31 0.63 0.58 0.62 89 100 0.29 0.28 0.65 0.23 0.14 89 102 0.13 0.19 0.20 89 104 0.14 0.48 0.20 0.31 0.17 0.58 0.40 89 106 0.25 0.20 0.12 89 108 0.15 0.18 0.21 0.16 0.16 89 110 0.16 89 112 0.14 0.35 89 114 0.11 0.10 89 116 0.12 0.12 89 118 0.11 89 120 0.18 89 128 0.10 89 148 0.12 90 41 0.11 90 43 0.13 90 55 0.09 90 57 0.17 90 63 0.22 90 65 0.16 0.39 0.25 0.12 90 69 0.18 0.49 0.43 90 71 0.13 0.56 0.64 0.21 90 73 0.13 DEG 124 123 81 114 117 114 121 124 119 109 124 127 126 130 120 113 109 123 103 61 125 112 108 124 116 124 130 124 123 113 128 128 132 143 144 124 133 61 105 80 107 80 120 99 96 84 114 125 69 118 104 56 62 136 122 66 122 94 114 54 81 74 83 150 155 112 121 128 146 125 121 153 127 120 119 150 118 124 141 141 CHNN IND P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD

%TW LOCATION 14 AV5

+0.00 13 AV6

+0.00 6

AVI

+0.00 18 AV7

+0.00 6

AV2

+0.00 6

AV3

+0.00 9

AV8

+0.00 9

AV7

+0.00 18 AV4

+0.00 17 AV2

+0.00 9

AV7

+0.00 16 AV6

+0.00 7

AV5

+0.00 10 AV4

+0.00 14 AV2

+0.00 7

AV8

+0.00 16 AV6

+0.00 14 AV4

+0.00 5

AV3

+0.00 6

AV2

+0.00 6

AVI

+0.00 7

AV6

+0..00 5

AV5

+0.00 5

AV4

+0.00 18 AV3

+0.00 11 AV7

+0.00 19 AV6

+0.00 18 AV4

+0.00 19 AV2

+0.00 11 AV7

+0.00 10 AV6

+0.00 19 AV5

+0.00 9

AV4

+0.00 6

AV2

+0.00 5

AV7

+0.00 7

AV2

+0.00 8

AVI

+0.00 5

AV8

+0.00 15 AV7

+0.00 7

AV6

+0.00 11 AV5

+0.00 7

AV4

+0.00 17 AV3

+0.00 13 AV2

+0.00 9

AV6

+0.00 7

AV4

+0.00 5

AV3

+0.00 7

AV6

+0.00 8

AV5

+0.18 9

AV3

+0.00 7

AV2

+0.00 7

AVl

+0.00 7

AV7

+0.00 7

AV7

-0.02 14 AV2

+0.00 5

AV5

-0.18 5

AV4

+0.00 6

AV5

-0.20 6

AV4

-0.04 6

AV4

+0.00 10 AV5

+0.00 6

AV4

+0.00 6

AVl

-0.22 4

AV4

+0.13 5

AV5

+0.00 3

AV4

+0.02 6

AV5

+0.13 8

AV3

+0.00 6

AVI

+0.00 13 AV2

+0.09 9

AV3

+0.09 4

AV4

+0.04 7

AV4

+0.13 15 AV5

+0.15 14 AV7

+0.09 5

AV3

+0.00 17 AV4

+0.07 18 AV5

+0.02 8

AV7

+0.11 5

AV2

+0.00 EXT EXT TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC UTIL 1

UTIL 2

CAL # LEG 11 COLD 11 COLD 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 20 HOT 20 HOT 20 HOT 20 HOT.

20 HOT 20 HOT 20 HOT 20 HOT 20 HOT 20 HOT 20 HOT 20 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 NOT 29 HOT 29 HOT 29 HOT 29 HOT 29 HOT 29 HOT 27 HOT 27 HOT 27 HOT 27 HOT 27 HOT 27 HOT 25 HOT 25 HOT 21 HOT 3

HOT 21 COLD 21 COLD 17 COLD 17 COLD 15 COLD 15 COLD 15 COLD 15 COLD 15 COLD 15 COLD 15 COLD 15 COLD 13 COLD 13 COLD 13 COLD 13 COLD 13 COLD PROBE 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TDL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:35 Component: S/G A Page 41 of 73 Component: S/C A Page 41 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 41 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.36 0.68 0.42 0.25 90 75 0.16 0.29 0.45 0.28 0.40 0.21 0.40 0.14 90 77 0.45 0.38 0.37 0.50 0.18 0.64 90 79 0.23 0.25 0.53 0.13 90 81 0.12 0.25 0.71 0.28 90 83 0.18 0.27 0.38 0.40 90 85 0.12 0.20 0.34 0.41 0.13 90 87 0.19 0.25 0.12 90 89 0.46 0.45 0.29 0.50 90 91 0.18 90 93 0.23 0.25 90 95 0.41 90 97 0.25 0.16 0.49 90 99 0.15 0.35 0.36 0.25 0.22 0.11 90 101 0.11 90 103 0.31 0.32 0.71 0.55 0.57 0.28 90 105 0.14 0.27 0.29 0.34 0.25 90 107 0.17 0.13 90 111 0.13 90 113 0.19 0.16 90 125 0.13 90 127 0.13 0.11 90 129 0.10 90 131 0.11 0.13 90 133 0.12 0.13 DEG CHN 123 P2 120 P2 117 P2 122 P2 137 P2 129 P2 126 P2 133 P2 118 P2 139 P2 124 P2 131 P2 123 P2 125 P2 126 P2 120 P2 127 P2 121 P2 133 P2 129 P2 131 P2 123 P2 116 P2 116 P2 124 P2 133 P2 129 P2 127 P2 113 P2 125 P2 81 P2 113 P2 116 P2 107 P2 123 P2 106 P2 88 P2 79 P2 124 P2 95 P2 98 P2 118 P2 87 P2 114 P2 108 P2 107 P2 105 P2 115 P2 114 P2 109 P2 110 P2 106 P2 117 P2 83 P2 131 P2 53 P2 108 P2 84 P2 104 P2 107 P2 112 P2 102 P2 48 P2 102 P2 108 P2 82 P2 91 P2 87 P2 56 P2 102 P2 110 P2 123 P2 125 P2 154 P2 147 P2 50 P2 46 P2 84 P2 82 P2 94 P2 IND %TW TWD 12 TWD 19 TWD 14 TWD 9 TWD 6 TWD 10 TWD 14 TWD 10 TWD 13 TWD 8 TWD 13 TWD 5 TWD 14 TWD 13 TWD 12 TWD 16 TWD 7 TWD 19 TWD 8 TWD 9 TWD 16 TWD 5 TWD 4 TWD 8 TWD 18 TWD 9 TWD 6 TWD 9 TWD 12 TWD 12 TWD 4 TWD 7 TWD 11 TWD 12 TWD 4 TWD 9 TWD 11 TWD 6 TWD 17 TWD 17 TWD 12 TWD 18 TWD 8 TWD 10 TWD 11 TWD 16 TWD 11 TWD 8 TWD 18 TWD 8 TWD 15 TWD 15 TWD 11 TWD 10 TWD 6 TWD 6 TWD 11 TWD 11 TWD 19 TWD 16 TWD 17 TWD 10 TWD 5 TWD 10 TWD 10 TWD 12 TWD 9 TWD 7 TWD 5 TWD 6 TWD 9 TWD 7 TWD 7 TWD 5 TWD 5 TWD 6 TWD 7 TWD 8 TWD 7 TWD 8 LOCATION AV3

+0.07 AV6

+0.09 AV7

+0.13 AV8

+0.13 AVI

+0.00 AV2

+0.09 AV3

+0.07 AV4

+0.11 AV5

+0.11 AV6

+0.07 AV7

+0.13 AV8

+0.07 AV4

+0.11 AV5

+0.13 AV7

+0.04 AV8

+0.07 AV2

+0.02 AV3

+0.17 AV3

+0.09 AV4

+0.07 AV5

+0.04 AV6

+0.13 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV7

+0.00 AV2

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV6

+0.00 AV8

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV2

+0.00 AV3

+0.00 AV7

+0.00 AV6

+0.00 AV2

-0.15 AV7

+0.00 AV3

+0.00 AV7

+0.00 AV7

+0.00 AV6

+0.00 AV4

+0.00 AVI

+0.00 AV2

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV2

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV8

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV7

+0.00 AV5

+0.00 AV4

+0.00 AV4

+0.00 AV6

-0.09 AV3

-0.07 AV3

-0.09 AV5

+0.00 AV4

+0.00 AV4

+0.00 AV4

+0.00 AV3

+0.00 AV4

+0.00 AV3

+0.00 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL #

13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 17 17 17 17 17 17 17 17 17 11 11 11 17 17 17 17 17 17 17 17 17 17 17 17 19 19 19 19 19 19 19 19 19 19 30 30 30 30 30 30 30 30 30 30 30 30 30 29 27 27 25 24 24 21 21 21 21 21 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 61OUL 61OUL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 61OUL 610UL 61OUL 61OUL 61OUL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 61OUL 61OUL 61OUL 610UL 61OUL 61OUL 61OUL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:35 Component: S/G A Page 42 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 42 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 91 70 0.12 0.14 0.13 91 72 0.19 0.44 0.53 91 74 0.11 0.18 0.27 0.52 91 76 0.13 0.47 0.53 0.55 0.60 91 78 0.24 0.32 0.59 0.20 91 80 0.30 0.28 0.32 0.43 0.15 91 82 0.15 0.33 0.27 0.20 0.32 0.49 91 84 0.17 91 86 0.17 0.38 91 88 0.33 0.35 0.14 0.11 91 90 0.53 0.46 0.09 91 92 0.24 0.53 91 94 0.15 0.37 0.43 91 96 0.39 0.20 0.12 0.34 0.35 0.41 0.23 91 98 0.31 0.46 0.22 91 100 0.37 0.16 0.14 0.12 0.15 91 102 0.25 0.24 0.42 91 104 0.26 91 106 0.15 0.27 0.19 0.11 91 108 0.23 0.18 0.32 91 110 0.24 91 112 0.12 0.59 91 114 0.15 91 116 0.11 0.16 91 118 0.16 92 47 0.14 92 51 0.15 DEG CHN 138 P2 130 P2 114 P2 144 P2 132 P2 127 P2 130 P2 131 P2 127 P2 124 P2 90 P2 120 P2 123 P2 123 P2 123 P2 133 P2 132 P2 122 P2 118 P2 133 P2 130 P2 126 P2 130 P2 93 P2 123 P2 128 P2 135 P2 130 P2 124 P2 122 P2 104 P2 98 P2 112 P2 97 P2 110 P2 108 P2 119 P2 107 P2 113 P2 44 P2 118 P2 112 P2 107 P2 105 P2 110 P2 101 P2 113 P2 116 P2 106 P2 94 P2 105 P2 104 P2 112 P2 108 P2 97 P2 112 P2 103 P2 108 P2 118 P2 111 P2 118 P2 110 P2 113 P2 118 P2 104 P2 113 P2 119 P2 121 P2 108 P2 127 P2 110 P2 118 P2 111 P2 127 P2 69 P2 124 P2 108 P2 128 P2 129 P2 140 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWO TWD TWD

%TW 5

6 5

8 15 17 5

7 10 17 5

16 17 18 19 9

12 18 8

11 11 12 15 6

6 12 10 8

12 16 7

8 15 14 14 7

6 19 17 5

10 18 7

14 16 15 9

6 13 14 16 10 12 17 9

16 8

7 6

8 12 12 17 12 8

13 9

6 11 9

14 11 6

19 7

6 8

8 5

6 LOCATION AVI

+0.00 AV3

+0.00 AV5

+0.00 AV2

+0.04 AV3

+0.00 AV5

+0.00 AV2

+0.04 AV4

+0.00 AV5

+0.09 AV7

+0.00 AV2

+0.11 AV4

+0.11 AV5

+0.11 AV6

+0.00 AV7

+0.09 AV2

+0.07 AV3

+0.07 AV6

+0.04 AV7

+0.00 AV3

+0.07 AV4

+0.04 AV5

+0.11 AV6

+0.09 AV7

+0.13 AV2

+0.07 AV3

+0.02 AV4

+0.00 AV5

+0.02 AV6

+0.04 AV7

+0.07 AV3

+0.09 AV8

+0.00 AV2

+0.00 AV8

+0.00 AV6

+0.00 AV3

+0.00 AVI

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV5

+0.00 AV2

+0.00 AV8

+0.00 AV6

+0.00 AV3

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AVI

+0.00 AV6

+0.00 AV5

+0.00 AV2

+0.00 AV3

+0.00 AV7

+0.00.

AV2

+0.00 AVl

+0.02 AV6

+0.00 AV7

+0.00 AV6

+0.00 AV3

+0.00 AV2

+0.00 AV6

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

-0.07 AV5

-0.07 AV6

-0.02 AV4

-0.07 AV2

-0.07 AV2

+0.00 AV5

+0.00 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC UTIL 1

UTIL 2

CAL 3

3 3

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

15 15 15 15 15 15 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 11 11 11 11 11 11 11 11 11 11 11 11 1i 11 1i 11 11 10 10 9

9 9

9 5

5

  1. LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD PROBE 61OUL 610UL 610UL 61OUL 61OUL 61OUL 610UL 61OUL 61OUL 61OUL 610UL 610UL 61OUL 61OUL 610UL 61OUL 61OUL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 61OUL 61OUL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:35 Component: S/G A Page 43 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 43 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 92 53 0.09 92 67 0.29 0.13 92 69 0.35 0.12 92 71 0.23 0.63 92 73 0.18 0.12 0.29 0.30 0.24 92 75 0.27 0.46 0.54 0.24 92 77 0.59 0.54 0.59 0.19 92 79 0.45 0.14 0.35 0.26 0.39 92 81 0.53 92 83 0.46 0.59 92 85 0.22 0.52 0.13 0.53 0.11 92 87 0.35 0.52 0.31 0.54 0.11 92 89 0.43 0.37 0.36 92 91 0.24 0.28 0.31 0.11 92 93 0.31 0.18 0.31 0.57 92 95 0.38 92 97 0.13 92 99 0.14 0.18 0.21 0.17 0.34 0.44 0.43 92 101 0.37 92 103 0.25 0.13 0.14 92 105 0.34 0.35 0.18 92 109 0.13 92 i11 0.11 92 115 0.24 92 117 0.19 0.13 92 123 0.15 92 131 0.15 92 135 0.14 92 137 0.14 93 48 0.15 93 50 0.13 93 60 0.14 93 64 0.13 0.11 0.22 DEG CHN 140 P2 125 P2 133 P2 123 P2 134 P2 121 P2 123 P2 122 P2 143 P2 96 P2 113 P2 112 P2 124 P2 122 P2 123 P2 119 P2 124 P2 124 P2 122 P2 145 P2 124 P2 129 P2 131 P2 139 P2 127 P2 126 P2 119 P2 126 P2 105 P2 120 P2 123 P2 124 P2 138 P2 100 P2 112 P2 122 P2 110 P2 92 P2 105 P2 108 P2 93 P2 117 P2 110 P2 104 P2 65 P2 112 P2 76 P2 103 P2 106 P2 98 P2 63 P2 77 P2 80 P2 100 P2 103 P2 101 P2 104 P2 122 P2 115 P2 123 P2 96 P2 97 P2 115 P2 124 P2 107 P2 78 P2 83 P2 114 P2 100 P2 121 P2 73 P2 131 P2 154 P2 114 P2 130 P2 113 P2 141 P2 130 P2 126 P2 131 P2 IND %TW LOCATION TWD 4 AV4

+0.00 TWO 11 AV4

+0.00 TWO S AVS

+0.00 TWD 12 AV6

+0.00 TWD 5 AV7

+0.00 TWO 9 AV3

+0.00 TWD 19 AV4

+0.00 TWD 7 AV4

+0.00 TWD 5 AV2

+0.07 TWD 11 AV4

+0.00 TWD 11 AV4

+0.00 TWD 9 AV7

+0.00 TWD 10 AV3

+0.07 TWD 16 AV4

+0.07 TWD 17 AV5

+0.09 TWO 9 AV6

+0.00 TWO 18 AV2

+0.13 TWD 17 AV5

+0.09 TWD 18 AV7

+0.04 TWO 8 AV8

+0.09 TWO 15 AV3

+0.09 TWO 6 AV4

+0.13 TWO 13 AV5

+0.09 TWO 10 AV6

+0.02 TWO 14 AV7

-0.09 TWO 17 AV6

+0.11 TWO 16 AV2

+0.06 TWO 18 AV4

+0.06 TWO 9 AV2

+0.11 TWO 17 AV5

+0.11 TWD 5 AV6

+0.13 TWD 17 AV7

+0.09 TWO 5 AV8

+0.07 TWD 14 AV7

+0.00 TWD 19 AV6

+0.00 TWD 13 AV4

+0.00 TWD 19 AV3

+0.00 TWD 6 AV2

+0.00 TWD 16 AV6

+0.00 TWD 15 AV5

+0.00 TWD 15 AV3

+0.00 TWD 10 AV8

+0.00 TWD 12 AV7

+0.00 TWD 12 AV2

+0.00 TWD 5 AVI

+0.00 TWD 12 AV2

+0.00 TWD 8 AV8

+0.00 TWD 13 AV7

+0.00 TWD 19 AV4

+0.00 TWD 15 AV2

+0.00 TWO 6 AV6

+0.00 TWO 6 AV8

+0.00 TWO 8 AV7

+0.00 TWO 9 AV6

+0.00 TWO 8 AV5

+0.00 TWO 13 AV4

+0.00 TWO 16 AV3

+0.00 TWO 16 AV2

+0.00 TWO 16 AV3

+0.00 TWO 12 AV5

+0.00 TWO 7 AV7

+0.00 TWO 7 AV2

+0.00 TWO 15 AV4

+0.00 TWO 15 AV5

+0.00 TWO 9 AV8

+0.00 TWO 7 AV4

+0.00 TWO 5 AV6

-0.28 TWO 11 AV5

-0.07 TWO 9 AV7

-0.02 TWO 7 AV4

-0.07 TWO 7 AV5

+0.00 TWO 7 AV3

-0.04 TWO 5 AV5

+0.00 TWO 7 AV4

-0.07 TWO 6 AV5

+0.21 TWO 6 AV5

+0.00 TWO 6 AV3

+0.00 TWO 5 AV3

+0.00 TWO 5 AV4

+0.00 TWO 9 AV6

+0.00 EXT EXT TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEE TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC UTIL 1

UTIL 2

CAL 5

3 3

3 3

3 3

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

15 15 15 15 15 15 15 15 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 11 11 11 11 11 11 11 11 10 9

9 9

7 7

8 7

6 6

4 4

4 4

  1. LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD NOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT NoT NOT COLD COLD COLD COLD COLD COLD PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:36 Component: S/G A Page 44 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 44 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.16 93 68 0.14 93 70 0.11 0.31 0.15 0.14 93 72 0.32 0.32 0.48 0.55 0.35 0.46 0.24 93 74 0.33 0.56 0.22 93 76 0.39 0.47 0.45 0.19 93 78 0.33

0. 32 0.25 0.49 0.23 0.45 93 80 0.15 0.21 0.16 0.17 93 82 0.30 0.23 0.46 0.34 0.25 0.63 93 84 0.34 93 86 0.45 0.29 0.22 93 88 0.17 0.15 0.30 0.56 0.49 0.38 0.15 93 90 0.66 93 92 0.55 0.44 93 94 0.52 0.36 93 96 0.12 0.31
0. 61 93 98 0.17 0.20
0. 12 93 100 0.24 0.21 93 102 0.25 0.53 0.45 0.44 0.68 0.30 93 104 0.26 0.73 0.61 0.37 0.12 93 106 0.12 0.53 0.35 0.19 93 108 0.16 0.21 93 110 0.57 0.73 93 114 0.13 DEG CHN 90 P2 125 P2 108 P2 124 P2 124 P2 125 P2 98 P2 112 P2 119 P2 118 P2 108 P2 110 P2 106 P2 120 P2 113 P2 117 P2 114 P2 112 P2 113 P2 103 P2 114 P2 113 P2 99 P2 109 P2 117 P2 109 P2 102 P2 109 P2 88 P2 107 P2 103 P2 99 P2 114 P2 102 P2 105 P2 113 P2 110 P2 115 P2 90 P2 127 P2 105 P2 128 P2 130 P2 117 P2 125 P2 123 P2 136 P2 119 P2 117 P2 127 P2 128 P2 126 P2 135 P2 135 P2 128 P2 127 P2 135 P2 107 P2 133 P2 137 P2 133 P2 121 P2 121 P2 123 P2 122 P2 128 P2 123 P2 125 P2 117 P2 126 P2 157 P2 120 P2 130 P2 132 P2 145 P2 140 P2 138 P2 122 P2 122 P2 144 P2 IND %TW TWD 7 TWD 6 TWD 5 TWD 11 TWD 6 TWD 6 TWD 11 TWD 11 TWD 15 TWD 17 TWD 12 TWD 15 TWD 9 TWD 12 TWD 17 TWD 8 TWD 13 TWD 15 TWD 15 TWD 7 TWD 12 TWD 11 TWD 9 TWD 16 TWD 9 TWD 15 TWD 6 TWD 8 TWD 6 TWD 7 TWD 11 TWD 9 TWD 15 TWD 12 TWD 9 TWD 19 TWD 12 TWD 15 TWD 10 TWD 9 TWD 7 TWD 6 TWD 11 TWD 17 TWD 16 TWD 13 TWD 6 TWD 19 TWD 17 TWD 15 TWD 17 TWD 13 TWD 5 TWD 11 TWD 18 TWD 7 TWD 8 TWD 5 TWD 9 TWD 8 TWD 9 TWD 16 TWD 14 TWD 14 TWD 19 TWD 10 TWD 9 TWD 19 TWD 17 TWD 12 TWD 5 TWD 5 TWD 16 TWD 12 TWD 7 TWD 6 TWD 8 TWD 17 TWD 19 TWD 6 LOCATION AV7

+0.00 AV7

+0.00 AV3

+0.00 AV4

+0.00 AVS

+0.00 AV7

+0.02 AVI

+0.20 AV2

-0.11 AV4

+0.29 AV6

+0.00 AV7

+0.18 AV8

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV3

+0.00 AV3

+0.00 AV4

+0.33 AV7

+0.00 AV8

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.35 AV7

+0.00 AV3

+0.00 AV4

+0.00 AVS

+0.00 AV8

-0.29 AV2

+0.00 AV3

+0.00 AV4

+0.29 AV5

+0.00 AV6

+0.00 AV7

+0.31 AV3

+0.29 AV2

+0.00 AV3

+0.00 AV7

+0.00 AVI

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV8

+0.00 AV2

+0.00 AV2

+0.00 AV7

+0.00 AV5

+0.00 AV7

+0.00 AV2

+0.00 AV6

+0.00 AV7

+0.00 AV3

+0.00 AV5

-0.18 AV2

+0.00 AV3

+0.00 AV5

+0.00 AVI

+0.00 AV2

+0.00 AV3

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV8

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV7

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 EXT EXT TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL 4

4 4

4 4

4 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

22 16 16 16 16 16 16 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 10

  1. LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD NOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610DL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UDL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610TUL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:36 Component: S/G A Page 45 of 73 Component: S/C A Page 45 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 45 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 93 116 0.10 93 126 0.14 93 128 0.15 0.14 94 53 0.14 94 59 0.17 94 61 0.17 94 63 0.25 0.15 94 65 0.22 0.17 94 67 0.16 0.12 94 69 0.22 94 71 0.34 0.25 0.13 0.19 94 73 0.41 0.37 0.41 0.52 94 75 0.43 0.55 0.22 94 77 0.23 0.38 0.43

0. 17 0.29 0.25 94 79 0.57 0.14 0.11 0.27 0.23 94 81 0.14 0.42 0.58 0.40 94 83 0.61 0.22 94 87 0.39 0.55 0.46 0.30 94 89 0.33 94 91 0.39 0.42 0.50 94 93 0.19 0.41 0.17 94 95 0.14 0.47 0.27 94 97 0.15 0.29 0.28 0.41 94 99 0.48 94 101 0.25 0.41 0.15 0.12 94 103 0.31 0.42 94 105 0.25 0.21 94 109 0.21 0.14 94 111 0.22 94 113 0.09 95 52 0.12 95 54 0.09 95 62 0.15 95 64 0.25 0.14 95 68 0.13 0.12 DEG CHN 100 P2 146 P2 99 P2 117 P2 115 P2 141 P2 132 P2 115 P2 137 P2 119 P2 138 P2 135 P2 137 P2 137 P2 119 P2 120 P2 124 P2 124 P2 119 P2 127 P2 133 P2 120 P2 112 P2 118 P2 136 P2 107 P2 115 P2 117 P2 84 P2 118 P2 103 P2 115 P2 114 P2 159 P2 127 P2 130 P2 136 P2 132 P2 128 P2 130 P2 111 P2 101 P2 124 P2 117 P2 127 P2 131 P2 105 P2 101 P2 108 P2 109 P2 108 P2 105 P2 96 P2 113 P2 115 P2 107 P2 82 P2 95 P2 113 P2 120 P2 116 P2 110 P2 124 P2 136 P2 110 P2 112 P2 112 P2 11 P2 136 P2 140 P2 142 P2 136 P2 79 P2 126 P2 130 P2 146 P2 123 P2 145 P2 145 P2 137 P2 IND %TW TWO 5 TWD 5 TWD 7 TWD 7 TWD 5 TWD 7 TWO 7 TWD 9 TWD 6 TWD 9 TWD 7 TWD 6 TWD 5 TWD 8 TWD 12 TWD 10 TWD 5 TWD 7 TWD 14 TWD 13 TWD 14 TWD 17 TWD 15 TWD 17 TWD 9 TWD 9 TWD 13 TWD 14 TWD 7 TWD 11 TWD 9 TWD 18 TWD 6 TWD 5 TWD 10 TWD 9 TWD 6 TWD 14 TWD 18 TWD 14 TWD 18 TWD 8 TWD 13 TWD 17 TWD 15 TWD 11 TWD 14 TWD 15 TWD 16 TWD 18 TWD 8 TWD 16 TWD 8 TWD 6 TWD 17 TWD 11 TWD 7 TWD 12 TWD 12 TWD 15 TWD 17 TWD 12 TWD 17 TWD 8 TWD 6 TWD 14 TWD 17 TWD 12 TWD 10 TWD 8 TWD 5 TWD 9 TWD 4 TWD 5 TWD 3 TWD 6 TWD 9 TWD 6 TWD 5 TWD 5 LOCATION AV5

+0.00 AV4

+0.00 AV5

-0.02 AV2

-0.07 AV2

+0.00 AV4

+0.00 AV4

+0.00 AV3

+0.00 AV4

+0.00 AV4

+0.00 AV7

+0.13 AV4

+0.00 AV7

+0.00 AV4

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AVI

+0.00 AV2

+0.09 AV3

+0.00 AV4

+0.00 AV3

+0.07 AV4

+0.00 AV8

+0.11 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV8

+0.00 AV2

+0.13 AV3

+0.09 AV5

+0.18 AV6

+0.09 AV7

+0.11 AV3

+0.07 AV5

+0.04 AV6

+0.09 AV7

+0.02 AV2

-0.15 AV8

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV7

+0.00 AV7

+0.00 AV7

+0.00 AV6

+0.00 AV2

+0.00 AV8

+0.00 AV4

+0.00 AVI

+0.00 AV8

+0.00 AV4

+0.00 AV2

-0.20 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV3

+0.00 AV5

-0.15 AV7

+0.00 AV5

+0.00 AV6

+0.00 AV3

+0.00 AV6

+0.00 AV4

+0.00 AV7

+0.00 AV6

+0.00 AV6

-0.13 AV5

+0.00 AV4

+0.00 AV2

+0.00 AV5

+0.00 AV6

+0.00 AV2

+0.00 AV3

+0.00 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC UTIL 1

UTIL 2

CAL #

10 8

7 7

5 6

3 3

3 4

4 3

3 3

4 4

4 4

1 1

1 1

1 1

1 2

2 2

2 2

2 1

1 1

1 1

1 1

11 2

2 16 16 16 16 15 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 11 11 11 11 11 11 11 12 12 10 10 5

5 3

3 3

3 3

LEG HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD PROBE 610UL 610UL 610UL 610UL 610UL 6100L 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TDL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610OL 610UL 610OL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 6100L 610UL 610UL 610UL 61OUL 610OL 610OL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610OL 610UL 610UL 610UL 610UL 610UL 610UL 610UDL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:36 Component: S/G A Page 46 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 46 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.13 95 70 0.20 0.13 95 72 0.33 95 74 0.20 0.21 0.35 0.31 0.41 0.16 95 76 0.24 0.38 0.29 0.19 95 78 0.31 0.22 0.11 0.31 0.11 0.23 95 80 0.23 0.53 0.28 0.41 95 82 0.62 0.23 0.21 0.34 95 84 0.54 0.26 0.23 95 86 0.27 95 88 0.10 0.12 95 90 0.26 0.29 95 92 0.16 0.39 95 94 0.44 95 96 0.22 0.23 95 98 0.12 0.31 0.35 0.40 95 100 0.12 0.23 0.16 0.18 95 102 0.24 95 104 0.13 0.23 95 106 0.13 0.13 95 108 0.14 95 110 0.11 95 116 0.21 95 120 0.11 95 128 0.33 0.14 96 27 0.16 96 53 0.09 0.11 96 59 0.11 96 63 0.17 96 67 0.16 0.12 96 69 0.19 0.14 96 71 0.38 0.34 0.19 0.23 96 73 0.18 0.62 0.67 0.28 0.41 0.41 96 75 0.30 DEG 130 138 126 121 134 127 128 126 129 134 132 125 133 131 126 121 138 136 128 131 131 126 136 126 123 129 128 122 121 126 110 106 59 90 105 113 103 115 112 97 113 114 89 108 118 105 108 97 108 ill 104 98 123 82 96 118 91 137 138 150 136 128 127 103 116 123 135 130 125 132 125 130 132 115 102 106 88 107 108 108 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW LOCATION 5

AV5

+0.00 8

AV2

+0.00 5

AV7

+0.00 12 AV3

+0.00 8

AV2

+0.07 8

AV3

+0.00 13 AV4

+0.07 11 AV5

+0.13 14 AV6

+0.00 6

AV7

+0.00 9

AV3

+0.07 13 AV4

+0.09 11 AV7

-0.07 8

AV8

-0.02 11 AV2

+0.15 9

AV3

+0.09 5

AV4

+0.09 11 AV5

+0.07 5

AV6

-0.07 9

AV7

+0.02 9

AV3

+0.09 17 AV4

+0.07 11 AV5

+0.09 14 AV6

+0.00 19 AV7

+0.11 9

AV2

+0.07 8

AV3

+0.09 12 AV6

+0.07 17 AV2

+0.09 10 AV3

+0.07 9

AV7

+0.04 12 AV2

+0.00 5

AV3

+0.00 6

AV2

+0.00 11 AV8

+0.00 12 AV2

+0.00 7

AV8

+0.00 15 AV2

+0.00 16 AV7

+0.00 10 AV7

+0.00 10 AV4

+0.00 6

AV6

+0.00 12 AV5

+0.00 14 AV4

+0.00 15 AV2

+0.00 6

AV3

+0.00 11 AV5

+0.00 8

AV6

+0.00 9

AV7

+0.00 11 AV5

+0.00 7

AV6

+0.00 11 AV5

+0.00 7

AV4

+0.00 7

AV5

+0.00 7

AV3

+0.00 6

AV4

+0.00 10 AV2

-0.07 6

AV3

-0.35 11 AV4

+0.00 5

AV3

+0.00 7

AV2

+0.00 4

AV2

+0.00 5

AV5

+0.07 4

AV4

+0.00 7

AV4

+0.00 7

AV5

+0.00 5

AV6

+0.00 8

AV3

+0.00 6

AV6

+0.00 13 AV3

+0.00 12 AV4

+0.00 7

AV5

+0.00 9

AV7

+0.00 7

AVI

+0.00 19 AV4

+0.24 19 AV5

+0.00 10 AV6

+0.00 14 AV7

+0.00 14 AV8

+0.00 11 AV2

+0.00 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH. TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC UTIL 1

UTIL 2

CAL 3

3 3

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 11 1

1 1

1 1

1 1

1 1

15 15 15 13 13 13 13 13 13 13 13 13 13 13 11 11 11 11 ii 11 11 ii ii ii 11 9

9 8

8 54 6

6 5

4 4

4 4

4 3

3 3

3 2

2 9

2 2

  1. LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UDL 610UL 610UL 61OUL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:36 Component: S/G A Page 47 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 47 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.20 0.28 0.38 0.33 96 77 0.14 0.12 0.20 96 79 0.35 0.64 0.63 0.54 0.41 96 81 0.27 0.43 96 83 0.17 0.42 0.20 0.11 96 85 0.11 0.23 0.37 0.55 0.15 96 87 0.47 0.52 96 89 0.13 0.39 96 91 0.12 0.58 0.41 96 93 0.31 96 95 0.42 0.16 0.37 0.26 0.51 96 97 0.24 0.20 96 99 0.17 0.56 0.16 0.10 96 101 0.19 0.23 0.13 0.31 96 103 0.15 0.25 0.43 0.20 0.23 0.33 0.25 96 105 0.29 0.23 96 127 0.12 97 52 0.14 0.08 97 60 0.12 97 62 0.14 97 64 0.18 0.19 97 66 0.14 0.14 0.14 97 68 0.25 0.53 0.14 0.17 0.18 97 70 0.20 0.22 97 72 0.16 0.35 0.34 0.42 0.36 97 74 0.50 0.45 0.35 DEG CHN 94 P2 116 P2 112 P2 109 P2 129 P2 129 P2 118 P2 118 P2 107 P2 111 P2 111 P2 106 P2 80 P2 107 P2 117 P2 117 P2 125 P2 133 P2 142 P2 121 P2 127 P2 118 P2 122 P2 111 P2 117 P2 94 P2 133 P2 115 P2 121 P2 114 P2 122 P2 117 P2 132 P2 127 P2 124 P2 133 P2 127 P2 121 P2 145 P2 120 P2 130 P2 132 P2 135 P2 123 P2 156 P2 128 P2 126 P2 126 P2 124 P2 136 P2 138 P2 124 P2 142 P2 140 P2 138 P2 149 P2 139 P2 93 P2 117 P2 138 P2 129 P2 99 P2 115 P2 99 P2 138 P2 121 P2 126 P2 119 P2 113 P2 111 P2 116 P2 123 P2 110 P2 102 P2 115 P2 109 P2 106 P2 106 P2 113 P2 105 P2 IND %TW TWD 8 TWD 10 TWD 13 TWD 12 TWD 6 TWD 5 TWD 8 TWD 12 TWD 19 TWD 19 TWD 17 TWD 14 TWD 10 TWD 14 TWD 7 TWD 15 TWD 8 TWD 5 TWD 5 TWD 9 TWD 13 TWD 18 TWD 6 TWD 17 TWD 19 TWD 5 TWD 13 TWD 5 TWD 18 TWD 14 TWD 11 TWD 14 TWD 7 TWD 13 TWD 10 TWD 16 TWD 9 TWD 8 TWD 7 TWD 17 TWD 6 TWD 4 TWD 7 TWD 8 TWD 5 TWD 11 TWD 6 TWD 9 TWD 14 TWD 8 TWD 8 TWD 11 TWD 9 TWD 10 TWD 8 TWD 5 TWD 6 TWD 4 TWD 5 TWD 6 TWD 7 TWD 8 TWD 6 TWD 6 TWD 6 TWD 10 TWD 17 TWD 6 TWD 7 TWD 7 TWD 8 TWD 9 TWD 6 TWD 12 TWD 12 TWD 14 TWD 12 TWD 16 TWD 15 TWD 12 LOCATION AV3 AV4 AV5 AV7 AV2 AV3 AV7 AV2 AV3 AV4 AV5 AV7 AV3 AV5 AVI AV2 AV7 AV8 AVI AV2 AV4 AV7 AV8 AV8 AV7 AVI AV2 AV2 AV3 AV7 AV2 AV2 AV3 AV4 AV5 1

AV6 AV3 AV8 AV2

+

AV3 1

AV4

+

AVl

+

AV7 1

AV6

+

AV4 AV3 AVI AV2

+

AV3 AV4 AV5 AV6 AV7 AV5 AV6 AV4 AV4 AV6 AV5

+

AV3 AV3

+

AV5 AV2

+

AV3 AV4 AV3

+

AV4

+

AV5 AV6

+

AV7 AV4 AV5

+

AV2 AV3 AV4 AV5

+

AV6 AV3

+

AV6

+

AV7

+

+0.00

+0.00

+0.00

+0.00

+0.18

+0.13

+0.15

-0.20

+0.33

+0.31

+0.33

+0.00

+0.00

-0.18

+0.09

+0.09

+0.09

+0.11

+0.13

+0.13

+0.07

+0.07

+0.11

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00 r0.00

+0.00

+0.00

+0.00

+0.00 0.00

+0.00

+0.00

+0.00

+0.00 0.00 0.00 0.00 0.00 0.00 10.00 10.00 0.00 10.00 10.00 10.00 10.00 10.00 10.00 0.00 10.00 0.00 0.00

-0.00 10.00

-0.00

-0.11

-0.04

-0.09

-0.13 10.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

+0.00 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC UTIL 1

UTIL 2

CAL #

2 2

2 2

1 1

1 2

2 2

2 2

2 2

1 1

1 1

1 1

1 1

15 15 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 12 12 12 12 12 12 12 12 12 12 12 12 12 8

6 6

4 4

4 4

4 4

4 4

4 4

4 4

4 4

2 2

2 2

2 2

22 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:36 Component: S/G A Page 48 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 48 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 97 76 0.40 0.49 0.27 0.17 97 78 0.45 0.45 0.22 0.52 97 80 0.63 0.44 0.57 97 82 0.15 0.50 0.19 0.18 0.20 97 84 0.58 0.56 0.63 97 86 0.13 0.65 0.63 0.38 97 88 0.47 0.33 97 90 0.33 0.55 0.14 97 92 0.14 0.30 97 94 0.14 0.21 0.15 0.44 0.23 0.19 97 96 0.19 0.66 0.37 0.43 0.30 97 98 0.44 0.13 0.09 97 100 0.21 0.30 0.58 0.12 0.31 0.18 97 102 0.31 0.28 0.33 97 104 0.20 0.54 97 106 0.24 0.13 97 108 0.22 97 112 0.10 97 116 0.11 98 53 0.12 0.14 98 63 0.12 98 65 0.12 98 69 0.27 0.20 98 71 0.33 0.18 0.12 98 73 0.34 0.55 0.20 0.29 0.40 98 75 0.27 0.22 0.16 0.15 0.35 98 77 0.22 DEG CHN 120 P2 11 P2 94 P2 111 P2 108 P2 112 P2 97 P2 107 P2 116 P2 118 P2 115 P2 115 P2 109 P2 97 P2 77 P2 100 P2 107 P2 112 P2 112 P2 88 P2 126 P2 123 P2 126 P2 120 P2 124 P2 120 P2 118 P2 142 P2 142 P2 126 P2 140 P2 134 P2 133 P2 130 P2 136 P2 139 P2 141 P2 125 P2 121 P2 127 P2 129 P2 127 P2 112 P2 135 P2 145 P2 127 P2 124 P2 153 P2 139 P2 150 P2 119 P2 132 P2 133 P2 138 P2 130 P2 139 P2 133 P2 134 P2 153 P2 149 P2 139 P2 128 P2 116 P2 123 P2 133 P2 133 P2 121 P2 117 P2 131 P2 131 P2 126 P2 120 P2 130 P2 124 P2 123 P2 131 P2 139 P2 134 P2 125 P2 94 P2 IND %TW TWD 14 TWD 16 TWD 10 TWD 7 TWD 15 TWD 15 TWD 9 TWD 16 TWD 19 TWD 15 TWD 17 TWD 6 TWD 16 TWD 7 TWD 7 TWD 8 TWD 18 TWD 17 TWD 19 TWD 5 TWD 19 TWD 19 TWD 13 TWD 15 TWD 12 TWD 12 TWD 17 TWD 6 TWD 6 TWD 11 TWD 6 TWD 8 TWD 6 TWD 15 TWD 9 TWD 7 TWD 7 TWD 19 TWD 13 TWD 14 TWD 11 TWD 15 TWD 5 TWD 4 TWD 8 TWD 10 TWD 17 TWD 5 TWD 11 TWD 7 TWD 11 TWD 10 TWD 11 TWD 7 TWD 16 TWD 9 TWD 5 TWD 8 TWD 5 TWD 5 TWD 5 TWD 5 TWD 5 TWD 5 TWD 10 TWD 8 TWD 12 TWD 7 TWD 5 TWD 12 TWD 18 TWD 8 TWD 11 TWD 14 TWD 10 TWD 9 TWD 6 TWD 6 TWD 13 TWD 8 LOCATION AV3 AV4 AV7 AV8 AV2 AV3 AV4 AV5 AV4 AV5 AV6 AV6 AV7 AV2 AV3 AV5 AV2 AV3 AV4 AVI AVS AV6 AV7 AV2 AV3 AV2 AV3 AV8 AVI AV8 AVI AV3 AV4 AV5 AV6 AV7 AV2 AV3 AV4 AV5 AV6 AV5 AV6 AV7 AVI AV2 AV3 AV4 AV5 AV7 AVI AV4 AV5 AVI AV5 AV2 AV3 AV4 AV5 AV5 AV2 AV4 AV3 AV3 AV5 AV7 AV3 AV4 AV5 AV2 AV3 AV4 AV5 AV6 AV2 AV4 AV5 AV6 AV8 AV2

+0.00

+0.33

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.38

-0.18

-0.20

+0.00

+0.29

+0.00

+0.00

-0.13

+0.31

+0.00

-0.20

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

-0.22

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

-0.22

-0.22

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.07

+0.00

+0.00

+0.02

+0.00

+0.00 EXT EXT TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC UTIL 1

UTIL 2

CAL #

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 16 16 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 12 12 12 12 12 12 12 12 12 12 12 12 12 12 10 10 5

5 3

4 3

3 4

4 4

1 1

1 1

1 1

1 1

1 1

2 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 61OUL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:36 Component: S/G A Page 49 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 49 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.25 98 79 0.23 0.35 0.35 0.21 98 81 0.46 0.36 0.41 0.19 0.11 0.20 0.48 98 83 0.17 0.34 0.44 98 87 0.28 98 89 0.17 0.20 0.26 98 91 0.46 0.53 0.13 98 93 0.22 0.43 0.51 0.17 98 95 0.43 0.50 98 97 0.18 0.13 0.15 98 99 0.16 0.25 0.17 98 101 0.14 0.37 0.42 98 103 0.14 0.25 98 105 0.26 0.19 0.12 98 107 0.16 0.14 0.15 98 109 0.16 98 11 0.11 98 113 0.08 0.07 98 119 0.09 98 123 0.12 98 141 0.10 99 54 0.10 0.11 99 62 0.12 99 68 0.16 99 70 0.15 0.23 99 72 0.16 0.39 0..62 0.31 99 74 0.14 0.23 0.28 0.25 0.32 99 76 0.27 0.45 0.43 99 78 0.38 0.32 0.21 0.13 0.41 0.20 99 80 0.14 0.25 0.46 0.13 DEG CHN 117 P2 122 P2 125 P2 132 P2 141 P2 127 P2 131 P2 126 P2 122 P2 112 P2 122 P2 122 P2 99 P2 108 P2 105 P2 132 P2 104 P2 96 P2 81 P2 104 P2 113 P2 65 P2 89 P2 100 P2 109 P2 100 P2 121 P2 111 P2 99 P2 72 P2 74 P2 73 P2 108 P2 84 P2 108 P2 117 P2 115 P2 116 P2 114 P2 122 P2 123 P2 84 P2 126 P2 120 P2 136 P2 129 P2 146 P2 141 P2 138 P2 127 P2 151 P2 37 P2 140 P2 137 P2 135 P2 119 P2 132 P2 130 P2 144 P2 133 P2 121 P2 131 P2 138 P2 127 P2 130 P2 111 P2 135 P2 118 P2 126 P2 122 P2 125 P2 135 P2 131 P2 138 P2 125 P2 129 P2 134 P2 120 P2 127 P2 150 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW 9

9 12 13 8

16 13 14 8

5 8

16 7

12 15 10 8

9 11 17 19 6

10 16 18 8

16 18 8

6 7

7 11 8

7 16 17 7

12 12 9

7 8

7 8

6 5

4 4

4 5

4 4

4 5

6 6

9 6

14 19 11 6

9 11 10 12 10 15 15 13 12 8

5 14 8

6 10 15 5

LOCATION AV3

+0.00 AV2

+0.09 AV4

+0.09 AV5

+0.09 AV6

+0.07 AV5

+0.13 AV6

+0.02 AV7

-0.02 AV8

+0.09 AVI

+0.04 AV2

+0.13 AV4

+0.07 AVi

+0.00 AV2

-0.22 AV7

-0.11 AV8

+0.00 AVI

+0.00 AV2

+0.00 AV8

+0.00 AV4

+0.00 AV3

+0.00 AVi

+0.00 AV7

+0.00 AV5

+0.00 AV3

+0.00 AV2

+0.00 AV5

+0.00 AV3

+0.00 AV6

+0.00 AV4

+0.00 AV3

+0.00 AV6

+0.00 AV4

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AVI

+0.00 AV7

+0.00 AV6

+0.00 AV4

+0.00 AV2

+0.00 AV6

+0.00 AV4

+0.00 AV3

+0.00 AV4

+0.00 AV6

+0.00 AV3

+0.00 AV2

+0.00 AV3

+0.00 AV5

-0.02 AVI

+0.00 AV2

+0.00 AV3

+0.04 AV5

+0.00 AV6

+0.00 AV3

+0.00 AV4

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.09 AV7

+0.00 AV2

+0.00 AV4

+0.00 AV5

+0.00

  • AV7

+0.00 AV8

+0.11 AV3

+0.15 AV4

+0.09 AV6

+0.02 AV2

+0.09 AV3

+0.04 AV4

+0.15 AV6

+0.13 AV7

+0.11 AV8

+0.15 AV2

+0.09 AV3

+0.04 AV4

+0.11 AV6

+0.18 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC UTIL 1

UTIL 2

CAL #

2 1

1 1

1 1

1 1

1 1

1 12 16 15 15 15 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 11 Ii 1i 11 11 11 11 11 1i 11 11 12 10 10 10 10 8

6 S

S 3

3 3

3 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UDL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:37 Component: S/G A Page 50 of 73 Component: BIG A Page 50 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 50 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 99 82 0.15 0.12 0.43 0.21 99 84 0.15 0.32 0.15 0.12 0.13 99 86 0.10 0.26 99 88 0.54 0.47 0.54 0.42 99 90 0.39 0.46 99 92 0.56 99 94 0.38 0.39 99 96 0.13 0.50 0.11 99 98 0.21 0.20 0.47 0.26 99 100 0.23 0.21 99 102 0.32 0.51 99 104 0.16 0.51 0.31 99 108 0.12 99 112 0.08 99 122 0.16 100 31 0.13 100 63 0.14 100 65 0.18 100 67 0.14 0.34 0.23 0.28 100 69 0.19 100 71 0.23 0.34 0.14 100 73 0.58 0.24 0.16 0.59 100 75 0.64 0.54 0.21 0.41 0.17 100 77 0.30 0.17 0.39 0.11 0.42 0.24 0.50 100 79 0.47 0.59 0.38 0.57 0.61 0.40 100 81 0.21 0.39 0.23 0.35 100 83 0.45 0.20 100 85 0.23 0.26 100 87 0.24 0.42 DEG 129 138 124 138 119 125 136 133 86 38 107 114 115 113 105 116 104 105 105 117 102 115 88 124 99 109 119 133 99 112 120 78 117 119 128 74 112 55 132 133 118 117 107 126 117 117 121 136 110 98 101 118 ill 107 84 ill 84 124 131 126 127 124 136 119 125 117 114 112 ill 91 115 104 117 100 119 139 120 115 75 110 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWO 6 TWO 5 TWO 15 TWO 8 TWO 6 TWO 12 TWO 6 TWO 5 TWO 5 TWO 5 TWO 11 TWO 19 TWO 17 TWO 19 TWO 16 TWO 15 TWO 17 TWO 19 TWO 15 TWO 15 TWO 6 TWD 18 TWD 5 TWD 9 TWD 9 TWO 17 TWO 11 TWD 11 TWO 10 TWO 14 TWO 19 TWO 8 TWO 19 TWO 14 TWO 6 TWO 4 TWO 7 TWO 6 TWO 6 TWO 7 TWD 6 TWD 12 TWD 9 TWD 10 TWO 8 TWO 9 TWO 12 TWO 6 TWO 18 TWO 9 TWO 6 TWO 18 TWO 19 TWO 17 TWO 8 TWO 14 TWD 7 TWD 11 TWO 7 TWD 14 TWO 5 TWO 15 TWD 9 TWO 16 TWO 15 TWO 18 TWO 13 TWO 17 TWO 18 TWO 14 TWD 8 TWD 13 TWD 9 TWO 12 TWO 15 TWO 8 TWO 9 TWO 10 TWO 11 TWO 16 LOCATION AV2

+0.13 AV4

+0.02 AV5

+0.07 AV7

+0.11 AVl

+0.09 AV2

+0.09 AV6

+0.09 AV7

+0.11 AV8

+0.15 AV8

+0.02 AVI

+0.00 AV8

+0.00 AV6

+0.00 AV5

+0.00 AVI

+0.00 AV8

+0.00 AV2

+0.00 AV4

+0.00 AV7

+0.00 AV2

+0.00 AV7

+0.00 AV5

+0.00 AV2

+0.00 AV8

+0.00 AV7

+0.00 AV4

+0.00 AV2

+0.00 AV7

+0.00 AVI

+0.00 AV6

+0.00 AV2

+0.00 AV4

+0.00 AV5

+0.00 AV7

+0.00 AV4

+0.00 AV2

+0.00 AV5

+0.00 AVl

+0.22 AV2

+0.04 AV3

+0.00 AVl

+0.00 AV3

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV3

+0.00 AV4

+0.00 AV7

+0.00 AV3

+0.00 AV5

+0.00 AV6

+0.00 AV8

+0.00 AV3

+0.00 AV4

+0.00 AV6

+0.00 AV7

+0.00 AV5

+0.09 AV7

+0.02 AV8

+0.11 AV2

+0.15 AV3

+0.15 AV4

+0.09 AV5

+0.11 AV6

+0.04 AV2

+0.00 AV3

+0.29 AV4

+0.00 AV5

+0.31 AV6

-0.18 AV7

-0.31 AV2

+0.00 AV3

+0.26 AV4

+0.00 AV8

-0.24 AV3

+0.02 AV8

+0.07 AVI

+0.09 AV8

+0.04 AV8

+0.00 AV3

+0.00 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH UTIL 1

UTIL 2

CAL #

1 1

1 1

1 1

1 1

1 15 15 15 15 15 15 13 13 13 13 13 13 13 13 13 13 13 13 11 11 10 11 11 11 11 11 10 7

57 4

3 4

4 4

4 4

3 3

3 2

2 2

2 2

2 2

2 1

1 1

11 1

1 2

2 2

2 2

2 2

2 2

2 1

1 1

1 15 15 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UC 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:37 Component: S/G A Page 51 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 51 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.30 100 89 0.14 0.22 0.56 100 91 0.30 0.20 0.39 0.15 100 93 0.25 0.41 100 95 0.59 0.45 0.11 0.30 100 97 0.10 0.13 0.32 0.30 0.09 100 99 0.48 100 101 0.30 0.20 0.37 0.17 0.20 100 103 0.35 0.35 0.24 100 105 0.32 0.56 0.19 0.15 100 107 0.21 0.55 0.21 100 111 0.13 0.08 100 121 0.13 0.14 101 52 0.16 101 60 0.15 101 62 0.11 101 70 0.15 101 72 0.35

.0.44 0.23 0.24 101 74 0.22 0.46 0.35 0.19 101 76 0.31 0.57 0.24 0.59 101 78 0.27 0.45 0.18 0.45 0.27 101 80 0.36 0.51 0.50 0.35 101 82 0.22 0.30 0.45 0.61 0.19 101 84 0.67 0.64 101 86 0.34 101 88 0.15 0.55 0.22 0.49 0.40 0.14 101 90 0.48 0.56 DEG 108 ill 110 127 125 85 120 136 119 124 122 130 124 136 135 104 129 125 148 124 135 142 129 144 113 130 127 127 138 124 144 149 137 126 142 137 161 88 123 105 102 123 128 97 113 102 ill 100 109 116 110 106 113 94 110 120 109 107 107 120 101 117 101 94 95 88 108 109 89 102 101 121 138 121 136 126 129 144 120 123 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2.

P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 22 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW LOCATION TWD 13 AV2

+0.00 TWD 6 AVi

+0.00 TWD 9 AV2

+0.00 TWD 17 AV7

+0.00 TWD 11 AV2

+0.00 TWD 8 AV3

+0.00 TWD 13 AV7

+0.00 TWD 6 AV8

+0.00 TWD 9 AV2

+0.00 TWD 14 AV5

+0.00 TWD 18 AV2

+0.00 TWD 15 AV4

+0.00 TWD 5 AV5

+0.00 TWD 11 AV6

+0.00 TWD 4 AV7

+0.00 TWD 5 AV5

+0.00 TWD 12 AV4

+0.00 TWD 11 AV3

+0.00 TWD 4 AV2

+0.00 TWD 16 AV3

+0.00 TWD 10 AV2

+0.00 TWD 7 AV4

+0.00 TWD 12 AV5

+0.00 TWD 6 AV6

+0.00 TWD 7 AV7

+0.00 TWD 12 AV3

+0.00 TWD 12 AV6

+0.00 TWD 9 AV7

+0.00 TWD 11 AV3

+0.00 TWD 17 AV4

+0.00 TWD 7 AV5

+0.00 TWD 6 AV7

+0.00 TWD 8 AV4

+0.00 TWD 16 AV6

+0.00 TWD 8 AV7

+0.00 TWD 6 AV6

+0.00 TWD 4 AV4

+0.00 TWD 6 AV5

-0.09 TWD 7 AV3

-0.09 TWD 7 AV5

+0.00 TWD 6 AV5

+0.00 TWD 5 AV3

+0.00 TWD 6 AV2

+0.00 TWD 12 AV4

+0.26 TWD 14 AV8

+0.00 TWD 9 AV6

+0.09 TWD 9 AV7

-0.09 TWD 8 AV2

+0.00 TWD 15 AV3

+0.00 TWD 12 AV5

+0.00 TWD 7 AV6

+0.00 TWD 11 AV2

+0.33 TWD 17 AV3

+0.00 TWD 9 AV5

+0.00 TWD 18 AV7

+0.00 TWD 10 AV2

+0.00 TWD 15 AV3

+0.00 TWD 7 AV5

+0.00 TWD 15 AV6

+0.31 TWD 10 AV7

+0.00 TWD 12 AV3

+0.00 TWD 16 AV5

+0.00 TWD 16 AV7

-0.20 TWD 12 AV8

+0.26 TWD 9 AV3

-0.15 TWD 11 AV4

+0.00 TWD 15 AV5

-0.15 TWD 18 AV7

+0.35 TWD 7 AV8

+0.00 TWD 19 AV4

-0.18 TWD 19 AV3

+0.00 TWD 12 AVI

+0.00 TWD 6 AVI

+0.00 TWD 17 AV2

+0.00 TWD 8 AV4

+0.00 TWD 16 AV5

+0.00 TWD 14 AV7

+0.00 TWD 6 AV8

+0.00 TWD 16 AV2

+0.00 TWD 17 AV4

+0.00 EXT TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEN TEH TEH TEN TEN TEN TEN TEH TEH TEH TEN TEN TEN TEN TEH TEH TEH TEN TEN TEN TEH TEN TEH TEH TEH TER TEN TEN TEH TEN TEH TEN TEC TEC TEC TEC TEC TEC TEC TEC TEC EXT TEN TEN TEN TEH TEN TEN TEH TEN TEN TER TEN TEN TEN TEH TEH TEN TEN TEN TEN TEN TEN TEN TEN TEH TEH TEN TEN TEN TEN TEN TEN TEN TEH TEN TEN TEN TEN TER TER TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEN TEN TEH TEH TE-TEH TEN TEN TER UTIL 1

UTIL 2

CAL 15 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 10 10 9

9 6

4 4

4 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

16 16 16 16 16 16 16 14 14

  1. LEG NOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD NOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 6100L 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UJL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610OL 61DUL 610UL 610UL 610UL 610UL 610UL 610DL 610TL 610UL 610UL 610UL 610UL 610UL 61OUL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:37 Component: S/G A Page 52 of 73 Bobbin AVE Wear Indications 1% to 19%

(Imperfect Tubes), Enc. 2 Page 52 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 QUERY: QueryMl ROW COL VOLTS 0.59 0.54 101 92 0.12 0.47 0.10 101 94 0.12 0.20 0.24 0.23 0.30 0.39 0.43 101 96 0.62 0.25 0.10 0.13 101 98 0.32 0.16 0.19 101 100 0.23 0.20 0.19 0.33 0.16 0.17 101 104 0.28 0.21 0.62 0.26 0.21 101 106 0.12 101 108 0.21 101 110 0.22 0.14 101 128 0.14 102 45 0.11 102 55 0.12 102 59 0.11 0.12 102 71 0.19 0.19 0.52 0.22 0.14 0.43 102 73 0.31 0.44 0.21 0.23 0.35 102 75 0.23 0.46 0.17 0.40 102 77 0.28 0.39 0.54 0.60 0.62 102 79 0.14 0.48 0.20 0.23 102 81 0.33 0.57 0.18 102 83 0.35 0.61 102 85 0.31 0.34 0.50 102 87 0.30 0.58 0.66 0.35 102 89 0.20 0.49 0.31 102 91 0.39 0.32 DEG 120 118 108 120 105 133 122 119 130 124 129 120 125 127 145 106 132 139 134 142 142 136 133 143 149 126 126 129 129 144 156 137 144 152 98 126 145 103 136 124 139 127 143 131 127 132 117 113 127 128 110 128 139 126 95 120 115 107 109 146 129 129 141 124 126 133 108 108 119 132 127 127 121 125 132 106 117 108 109 81 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %T TWD 18 TWD 17 TWD 5 TWD 15 TWD 4 TWD 5 TWD 8 TWD 9 TWD 9 TWD 11 TWD 13 TWD 14 TWD 19 TWD 9 TWD 4 TWD 5 TWD 12 TWD 6 TWD 7 TWD 8 TWD 8 TWD 7 TWD 11 TWD 6 TWD 6 TWD 10 TWD 8 TWD 18 TWD 9 TWD 8 TWD 5 TWD 8 TWD 8 TWD 5 TWD 7 TWD 5 TWD 5 TWD 5 TWD 6 TWD 7 TWD 7 TWD 16 TWD 8 TWD 6 TWD 14 TWD 11 TWD 15 TWD 8 TWD 9 TWD 12 TWD 9 TWD 15 TWD 7 TWD 14 TWD 10 TWD 13 TWD 17 TWD 18 TWD 18 TWD 6 TWD 16 TWD 8 TWD 9 TWD 12 TWD 18 TWD 7 TWD 12 TWD 18 TWD 11 TWD 12 TWD 16 TWD 11 TWD 18 TWD 19 TWD 12 TWD 9 TWD 18 TWD 13 TWD 15 TWD 13 N LOCATION AV6

+0.00 AV8

+0.00 AVl

+0.00 AV2

+0.00 AV7

+0.00 AVI

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV7

+0.00 AV8

+0.00 AV2

+0.00 AV4

+0.00 AV5

+0.00 AV7

+0.00 AV4

+0.00 AV5

+0.00 AV8

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AVI

-0.09 AV2

+0.00 AV3

+0.00 AV5

+0.00 AV6

+0.00 AV8

+0.00 AV4

+0.00 AV4

+0.00 AV4

+0.00 AV5

+0.00 AV5

-0.11 AV5

+0.11 AV4

, +0.00 AV2

+0.00 AV4

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV7

+0.00 AV6

+0.00 AV2

+0.00 AV3

+0.11 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV3

+0.04 AV4

+0.00 AV5

+0.00 AV6

+0.13 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV4

+0.04 AV5

+0.13 AV7

+0.09 AV8

+0.11 AV2

+0.18 AV6

+0.09 AV7

+0.11 AV2

+0.00 AV7

+0.00 AVI

+0.07 AV4

+0.07 AV7

+0.04 AVI

+0.00 AV3

+0.00 AV5

+0.00 AV8

+0.00 AV8

+0.00 AV7

+0.00 AV2

+0.00 AV6

+0.00 AV3

+0.00 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL # LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 61OUL 610UL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TDL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TDL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:37 Component: S/G A Page 53 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes), Enc. 2 Page 53 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 QUERY: QueryMl ROW COL VOLTS DEG 0.16 106 0.12 105 102 93 0.35 110 0.57 118 0.16 88 102 95 0.22 119 0.33 ii 0.32 116 0.18 115 0.35 98 102 97 0.13 124 0.16 88 0.19 103 0.27 100 102 99 0.29 114 0.22 117 0.35 108 0.27 112 102 105 0.21 124 0.14 133 103 54 0.13 136 103 56 0.12 129 103 60 0.16 140 103 70 0.12 135 0.12 146 103 72 0.22 138 0.55 127 0.49 129 103 74 0.30 130 0.31 122 0.27 130 0.15 137 0.29 128 0.44 131 103 76 0.22 120 0.33 123 103 78 0.41 118 0.35 130 103 80 0.52 124 0.17 139 0.64 120 0.28 114 0.36 134 103 82 0.37 121 0.50 121 0.45 124 103 84 0.30 122 0.61 127 0.53 130 103 86 0.17 109 0.54 120 0.20 128 103 88 0.25 103 0.25 116 0.22 84 103 90 0.20 91 0.30 105 0.44 106 0.25 90 103 92 0.23 90 0.52 106 0.57 109 0.16 88 103 94 0.26 i1 0.39 115 0.31 113 0.29 114 103 96 0.24 100 0.13 78 0.17 56 0.30 100 103 98 0.16 106 0.35 117 0.57 115 0.25 113 103 100 0.20 120 0.36 118 0.32 119 0.39 116 0.34 119 CNN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWD 7 TWD 6 TWD 14 TWD 19 TWD 7 TWD 9 TWD 13 TWD 13 TWD 8 TWD 14 TWD 6 TWD 7 TWD 9 TWD 11 TWD 12 TWD 10 TWD 14 TWD 11 TWD 10 TWD'7 TWD 5 TWD 5 TWD 6 TWD 5 TWD 5 TWD 8 TWD 17 TWD 16 TWD 11 TWD 11 TWD 10 TWD 6 TWD II TWD 15 TWD 8 TWD 12 TWD 14 TWD 13 TWD 17 TWD 7 TWD 19 TWD 11 TWD 13 TWD 13 TWD 16 TWD 15 TWD 11 TWD 19 TWD 17 TWD 8 TWD 19 TWD 9 TWD 11 TWD 11 TWD 10 TWD 9 TWD 12 TWD 16 TWD 11 TWD 10 TWD 18 TWD 19 TWD 7 TWD 11 TWD 15 TWD 13 TWD 12 TWD 10 TWD 6 TWD 8 TWD 12 TWD 7 TWD 14 TWD 19 TWD 11 TWD 10 TWD 16 TWD 14 TWD 16 TWD 15 LOCATION AV2

+0.00 AVl

+0.00 AV7

+0.00 AV5

+0.00 AV2

+0.00 AV7

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV7

+0.00 AV6

+0.00 AV4

+0.00 AV3

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV4

+0.00 AV3

+0.00 AV5

+0.00 AV5

+0.00 AV4

+0.00 AV4

+0.00 AV5

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AVI

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV8

+0.00 AV2

+0.18 AV4

+0.11 AV2

+0.13 AV6

-0.02 AV3

+0.09 AV4

+0.09 AV6

+0.11 AV7

+0.13 AV8

+0.11 AV2

+0.11 AV3

+0.07 AV8

+0.02 AVl

+0.07 AV3

+0.04 AV4

+0.02 AV8

+0.00 AV2

+0.00 AVI

+0.00 AV8

-0.07 AV4

+0.00 AV2

+0.00 AV8

+0.00 AV6

+0.00 AV3

+0.00 AV2

+0.00 AV8

+0.00 AV5

+0.00 AV2

+0.00 AVI

+0.00 AV8

+0.00 AV7

+0.00 AV6

+0.00 AV4

+0.00 AV7

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 11 11 5

5 3

3 3

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

15 15 15 15 15 15 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 11 11 11 11 ii LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 6100L 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL

AREVA NP Inc Customer Name: St Lucie 2 Replacement Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY:

QueryMl 12/14/12 11:34:38 Component: S/G A Page 54 of 73, Enc. 2 Page 54of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 103 104 0.41 103 106 0.16 0.15 0.50 103 112 0.09 0.28 104 71 0.28 0.14 0.33 0.44 0.12 104 73 0.27 0.57 0.44 0.50 0.32 104 75 0.42 0.57 0.44 0.54 0.25 0.30 104 77 0.39 0.40 104 79 0.30 0.22 0.41 0.36 0.22 104 81 0.16 0.31 0.28 104 83 0.38 0.60 0.06 104 85 0.62 104 89 0.25 0.40 0.36 104 91 0.31 0.42 0.44 104 93 0.16 0.15 0.67 0.44 104 95 0.10 0.18 0.29 0.11 104 97 0.14 0.46 0.14 0.25 104 99 0.14 0.26 104 105 0.49 0.39 0.32 0.41 104 107 0.17 0.12 104 117 0.09 105 52 0.11 105 66 0.14 105 72 0.26 0.44 0.67 0.53 105 74 0.25 0.21 0.18 0.23 105 76 0.41 0.49 0.55 0.33 0.27 105 78 0.47 0.42 DEG 115 132 101 117 143 118 ill 115 116 125 105 120 112 105 106 105 119 117 118 108 ill 115 134 123 110 92 110 109 97 100 108 1il 113 126 143 115 133 109 118 121 124 128 113 112 123 121 145 119 121 139 127 123 135 127 99 126 126 130 130 130 150 145 153 90 112 133 112 119 117 126 88 83 103 110 119 ill 105 113 107 95 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW LOCATION 17 AV4

+0.00 8

AV3

+0.00 8

AV4

+0.00 19 AV5

+0.00 4

AV3

+0.00 11 AV2

+0.00 10 AV2

+0.00 6

AV3

+0.00 12 AV4

+0.00 15 AV5

+0.00 5

AV6

+0.09 10 AV2

-0.11 18 AV3

+0.00 14 AV5

+0.00 16 AV6

-0.11 11 AV7

-0.20 14 AV2

+0.00 17 AV3

+0.00 15 AV4

+0.00 17 AV5

+0.00 9

AV6

+0.00 11 AV7

+0.00 14 AV4

+0.09 14 AV5

+0.07 11 AV2

+0.00 8

AV3

+0.00 14 AV4

+0.33 12 AV5

+0.35 9

AV6

-0.15 6

AV2

+0.00 11 AV4

+0.00 10 AV6

+0.00 13 AV2

+0.07 19 AV7

+0.07 3

AV8

+0.24 19 AV5

-0.20 9

AVI

+0.00 14 AV2

+0.00 13 AV8

+0.00 11 AVI

+0.00 14 AV6

+0.00 15 AV7

+0.00 6

AV2

+0.00 6

AV3

+0.00 19 AV4

+0.00 15 AV7

+0.00 4

AVl

+0.00 7

AV2

+0.00 11 AV4

+0.00 5

AV5

+0.00 6

AV3

+0.00 15 AV4

+0.00 6

AV5

+0.00 9

AV6

+0.00 6

AV2

-0.20 10 AV5

+0.00 15 AV7

+0.00 13 AV6

+0.00 11 AV5

+0.00 13 AV4

+0.00 6

AV3

+0.00 5

AV4

+0.00 4

AV3

+0.00 5

AV5

-0.15 6

AV3

+0.15 10 AV2

+0.00 15 AV3

+0.26 19 AV4

+0.40 17 AV5

+0.00 9

AV2

+0.00 8

AV3

+0.00 7

AV4

+0.00 9

AV5

+0.00 14 AV3

+0.00 16 AV4

+0.00 17 AV5

+0.00 12 AV6

+0.00 10 AV7

+0.00 15 AV3

. +0.00 14 AV6

+0.33 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC UTIL 1

UTIL 2

CAL #

10 10 4

4 4

4 4

2 2

2 2

2 2

2 2

2 2

2 1

1 2

2 2

2 2

2 2

2 1

1 1

2 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 12 12 12 12 12 12 10 6

4 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

LEG HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:38 Component: S/G A Page 55 of 73 Component: S/C A Page 55 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 55 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 105 80 0.18 0.27 0.55 0.45 0.31 0.21 105 82 0.28 0.56 0.27 105 84 0.38 0.65 0.57 105 86 0.19 0.15 105 88 0.11 0.57 0.13 105 90 0.55 0.65 0.25 105 92 0.33 0.64 105 94 0.48 0.09 0.46 0.25 105 96 0.14 0.36 0.17 105 98 0.24 0.13 0.44 0.49 0.30 105 100 0.35 0.31 0.16 0.12 0.12 105 104 0.36 0.30 0.17 0.12 105 106 0.18 105 112 0.12 105 114 0.08 106 53 0.15 106 69 0.16 106 71 0.10 0.19 0.42 0.41 106 73 0.14 0.14 0.30 0.54 0.22 0.44 0.21 106 75 0.11 0.18 0.46 0.26 106 77 0.16 0.51 0.33 0.44 106 79 0.18 0.11 0.22 0.46 106 81 0.14 0.50 106 83 0.37 0.18 0.20 106 87 0.43 0.20 106 89 0.44 0.55 DEG CHN 112 P2 104 P2 114 P2 115 P2 99 P2 107 P2 98 P2 115 P2 101 P2 104 P2 111 P2 111 P2 126 P2 138 P2 144 P2 131 P2 134 P2 119 P2 122 P2 121 P2 129 P2 124 P2 121 P2 132 P2 121 P2 122 P2 124 P2 126 P2 131 P2 120 P2 146 P2 124 P2 118 P2 130 P2 133 P2 135 P2 147 P2 148 P2 153 P2 128 P2 138 P2 132 P2 151 P2 142 P2 128 P2 66 P2 132 P2 134 P2 148 P2 132 P2 130 P2 132 P2 120 P2 140 P2 121 P2 129 P2 135 P2 133 P2 132 P2 129 P2 130 P2 129 P2 130 P2 82 P2 115 P2 114 P2 110 P2 131 P2 112 P2 126 P2 134 P2 101 P2 126 P2 119 P2 112 P2 108 P2 108. P2 94 P2 113 P2 109 P2 IND %TW TWD 7 TWD 10 TWD 17 TWD 15 TWD 11 TWD 8 TWD 10 TWD 17 TWD 10 TWD 13 TWD 19 TWD 18 TWD 7 TWD 6 TWD 5 TWD 17 TWD 5 TWD 17 TWD 19 TWD 9 TWD 12 TWD 19 TWD 16 TWD 4 TWD 15 TWD 10 TWD 6 TWD 13 TWD 7 TWD 9 TWD 5 TWD 15 TWD 16 TWD 11 TWD 12 TWD 11 TWD 6 TWD 5 TWD 5 TWD 12 TWD 10 TWD 6

TWD 5 TWD 7 TWD 6 TWD 4 TWD 5 TWD 7 TWD 4 TWD 8 TWD 14 TWD 14 TWD 6 TWD 6 TWD 11 TWD 17 TWD 8

TWD 15 TWD 8

TWD 5

TWD 7

TWD 16 TWD 10 TWD 6

TWD 16 TWD 12 TWD 14 TWD 7 TWD 5 TWD 9 TWD 15 TWD 6 TWD 16 TWD 13 TWD 7

TWD 8

TWD 16 TWD 9

TWD 17 TWD 19 LOCATION AV3

-0.15 AV4

+0.29 AV5

+0.00 AV6

+0.00 AV7

-0.20 AV8

+0.00 AV2

+0.00 AV6

-0.26 AV7

+0.31 AVI

+0.31 AV4

-0.17 AV5

+0.02 AV2

+0.00 AV8

+0.00 AVI

+0.00 AV7

+0.00 AV8

+0.00 AV2

+0.00 AV4

+0.00 AV8

+0.00 AV2

+0.00 AV6

+0.00 AV2

+0.00 AV6

+0.00 AV7

+0.00 AV8

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV7

+0.00 AV6

+0.00 AV6

+0.02 AV5

-0.02 AV4

+0.00 AV3

+0.00 AV5

-0.02 AV2

-0.31 AV5

+0.00 AV5

+0.00 AV7

+0.00 AV3

+0.00 AV2

+0.00 AV4

+0.00 AV5

+0.00 AVI

+0.11 AV2

+0.15 AV3

+0.11 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.07 AV3

+0.02 AV4

+0.07 AV5

+0.11 AV8

+0.07 AV2

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.11 AV2

+0.09 AV3

+0.13 AV4

+0.18 AV7

+0.11 AV3

+0.11 AV5

+0.20 AV7

+0.18 AV8

+0.09 AVI

+0.28 AV8

+0.00 AVI

+0.00 AV8

+0.00 AV4

+0.00 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1 UTIL 2

CAL #

2 2

2 2

2 2

2 2

2 2

2 2

16 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 12 12 12 12 12 12 12 12 12 12 1010 5

3 3

3 3

3 1

1 1

1 1

1 1

1 1

1 1

2 2

2 2

1 1

1 1

1 1

2 2

2 15 15 15 15 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT PROBE 610UL 610UL 61OUL 610UL 61OUL 61OUL 610UL 610UL 610UL 610OL 610UL 610UL 610UL 610UL 610UL 610UL 610OL 610UL 610UL 610UL 610UL 610UL 610OL 610UL 610UL 610UL 610OL 610UL 6100L 610UL 610UL 610UL 610UL 610UL 610DL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TDL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:38 Component: S/G A Page 56 of 73 Component: S/C A Page 56 off 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 56 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.49 0.22 0.10 106 91 0.16 0.44 0.20 106 93 0.16 0.44 0.18 106 95 0.17 0.57 0.47 0.45 0.45 0.38 0.15 106 97 0.43 0.22 0.16 106 99 0.13 0.20 0.22 0.12 0.15 106 101 0.18 0.18 106 103 0.50 0.25 0.27 106 121 0.18 107 50 0.11 107 68 0.16 0.12 107 70 0.49 0.30 0.20 107 72 0.14 0.11 0.24 0.27 107 74 0.30 0.23 0.52 0.37 107 76 0.14 0.16 0.11 0.21 107 78 0.18 0.43 0.14 0.15 0.29 0.38 107 80 0.48 0.21 107 82 0.34 0.46 107 86 0.52 0.52 0.32 107 88 0.37 107 90 0.33 0.50 0.34 107 92 0.33 0.57 0.14 107 94 0.20 0.40 107 96 0.44 0.12 0.50 0.53 0.31 0.21 107 98 0.19 0.17 0.22 0.32 DEG CHN 115 P2 107 P2 101 P2 98 P2 101 P2 106 P2 100 P2 104 P2 105 P2 110 P2 114 P2 110 P2 110 P2 111 P2 97 P2 75 P2 102 P2 97 P2 90 P2 79 P2 102 P2 111 P2 71 P2 90 P2 114 P2 102 P2 114 P2 119 P2 107 P2 106 P2 99 P2 125 P2 128 P2 126 P2 123 P2 132 P2 145 P2 104 P2 134 P2 138 P2 133 P2 133 P2 116 P2 130 P2 141 P2 144 P2 149 P2 138 P2 148 P2 125 P2 130 P2 130 P2 123 P2 131 P2 126 P2 127 P2 124 P2 120 P2 109 P2 110 P2 118 P2 114 P2 117 P2 106 P2 88 P2 115 P2 113 P2 97 P2 109 P2 113 P2 106 P2 99 P2 110 P2 107 P2 102 P2 109 P2 87 P2 81 P2 120 P2 116 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW 18 10 5

7 16 9

7 16 8

8 19 17 17 17 15 7

16 10 7

6 9

10 6

7 9

9 19 12 13 8

4 6

5 16 11 8

6 5

9 10 11 9

17 13 6

7 5

8 7

15 6

6 11 13 16 8

12 15 19 19 13 15 13 18 13 13 19 6

9 15 16 6

18 19 12 9

9 8

9 13 LOCATION EXT EXT AV3

+0.00 TEC TEH AV2

+0.00 TEC TEH AVI

+0.00 TEC TEH AV8

+0.00 TEC TEH AV2

+0.00 TEC TEH AVI

+0.00 TEC TEH AV7

+0.00 TEC TEH AV4

+0.00 TEC TEH AV2

+0.00 TEC TEH AV8

+0.00 TEC TEH AV6

+0.00 TEC TEH AV5

+0.00 TEC TEH AV4

+0.00 TEC TEH AV3

+0.00 TEC TEH AV2

-0.37 TEC TEH AVl

-0.33 TEC TEH AV4

+0.00 TEC TEH AV2

+0.00 TEC TEH AVI

+0.00 TEC TEH AV6

+0.00 TEC TEH AV5

+0.00 TEC TEH AV4

+0.00 TEC TEH AV3

+0.00 TEC TEH AVI

+0.00 TEC TEH AV5

+0.00 TEC TEH AV6

+0.00 TEC TEH AV3

+0.00 TEC TEH AV5

+0.00 TEC TEH AV6

+0.00 TEC TEH AV5

-0.07 TEC TEH AV4

+0.00 TEH TEC AV5

+0.00 TEH TEC AV7

+0.00 TEH TEC AV3

+0.00 TEH TEC AV4

+0.00 TEH TEC AV5

+0.00 TEH TEC AV2

+0.07 TEH TEC AV3

+0.00 TEH TEC AV4

+0.07 TEH TEC AV6

+0.00 TEH TEC AV4

+0.00 TEH TEC AV5

+0.00 TEH TEC AV6

+0.00 TEH TEC AV7

+0.00 TEH TEC AV2

+0.11 TEH TEC AV4

+0.04 TEH TEC AV5

+0.02 TEH TEC AV6

-0.02 TEH TEC AV2

+0.11 TEH TEC AV3

+0.00 TEH TEC AV4

+0.07 TEH TEC AV5

+0.07 TEH TEC AV6

+0.00 TEH TEC AV7

-0.07 TEH TEC AV4

+0.07 TEH TEC AV5

+0.09 TEH TEC AV2

+0.04 TEH TEC AV3

+0.09 TEH TEC AV6

+0.00 TEC TEH AV5

+0.00 TEC TEH AV2

+0.00 TEC TEH AV2

+0.00 TEC TEH AV8

+0.00 TEC TEH AV3

+0.00 TEC TEH AV2

+0.00 TEC TEH AV7

+0.00 TEC TEH AV2

+0.00 TEC TEH AVi

+0.00 TEC TEH AV7

+0.00 TEC TEH AV6

+0.00 TEC TEH AV6

+0.00 TEC TEH AV5

+0.00 TEC TEH AV4

+0.00 TEC TEH AV3

+0.00 TEC TEH AV2

+0.00 TEC TEH AVI

+0.00 TEC TEH AV2

+0.00 TEC TEH AV6

+0.00 TEC TEH AV5

+0.00 TEC TEH AV4

+0.00 TEC TEH UTIL 1

UTIL 2

CAL #

15 15 15 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 11 11 11 11 11 7

5 3

3 3

3 3

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

15 15 15 15 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 610UL 61OUL 61OUL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UDL 610UL 610UL 610UL 610UL 610UL 610DL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:38 Component: S/G A Page 57 of 73 Component: S/C A Page 57 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl Aftachment 1, Enc. 2 Page 57 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 107 100 0.28 0.17 0.10 107 102 0.18 0.25 0.17 107 104 0.12 0.11 0.32 107 112 0.12 107 120 0.14 108 35 0.14 108 37 0.12 108 69 0.22 0.14 0.21 108 71 0.55 0.26 0.34 0.43 0.20 108 73 0.21 0.29 0.54 0.33 0.27 108 75 0.43 0.36 0.34 108 77 0.64 0.27 0.46 108 79 0.18 0.52 0.28 0.29 108 81 0.35 0.45 0.56 0.62 0.46 0.22 108 83 0.32 0.59 108 85 0.33 0.62 0.45 108 87 0.11 0.67 0.38 108 89 0.15 108 91 0.22 0.40 108 93 0.13 0.63 0.65 0.52 0.37 108 95 0.30 0.28 0.09 108 97 0.40 0.18 108 99 0.23 0.31 108 101 0.15 0.18 0.30 0.53 0.12 0.12 108 103 0.15 0.68 0.16 108 105 0.12 0.26 0.28 0.17 108 107 0.17 109 60 0.14 DEG 117 101 85 96 126 105 112 139 118 145 125 81 95 136 123 122 131 120 126 114 112 105 113 108 97 103 101 109 101 130 122 123 99 112 122 115 107 108 108 109 107 94 129 126 124 125 114 123 120 117 120 117 121 133 123 122 123 129 121 130 140 122 133 114 131 130 147 126 126 147 147 144 124 148 151 128 136 134 142 131 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW LOCATION 13 AV4 9

AV3 5

AV2 9

AV6 12 AV5 9

AV4 6

AV4 6

AV5 14 AV3 5

AV2 7

AV6 6

AV8 5

AV8 8

AV2 6

AV3 8

AV7 17 AV2 10 AV3 12 AV4 15 AV6 8

AV7 8

AV2 11 AV3 17 AV4 12 AV5 10 AVl 14 AV4 12 AV6 12 AV7 19 AV4 10 AV5 16 AV7 7

AV3 16 AV4 10 AV5 11 AV6 12 AV2 15 AV3 17 AV5 18 AV6 15 AV7 8

AV8 12 AV2 18 AV7 12 AVI 19 AV4 15 AV8 5

AVl 19 AV3 13 AV8 6

AV2 8

AVI 14 AV7 5

AVI 19 AV2 19 AV5 17 AV6 13 AV7 11 AV5 10 AV8 4

AVI 14 AV4 7

AV5 9

AVI 11 AV4 6

AV6 7

AV4 10 AV3 16 AV2 5

AVl 5

AV7 6

AV2 19 AV4 6

AV5 5

AV7 9

AV6 10 AV5 6

AV4 6

AV3 6

AV5

+0.00

+0.00

+0.00

+0.00

+0.00

-0.04

+0.00

+0.00

+0.00

-0.37

-0.09

+0.26

+0.13

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.26

+0.00

+0.00

+0.00

+0.04

+0.07

+0.20

+0.00

+0.00

+0.26

-0.18

+0.00

+0.35

+0.00

+0.33

-0.24

+0.00

+0.04

+0.02

+0.13

+0.04

+0.07

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

-0.11

-0.04

-0.04

-0.04

+0.00

+0.00 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC UTIL 1

UTIL 2

CAL 10 11 57 57 11 11 11 11 1i 10 9

57 57 4

4 4

4 4

4 4

4 2

2 2

2 2

2 2

1 1

1 2

2 2

2 2

2 2

2 22 1

1 1

1 1

16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 12 12 12 12 12 12 12 12 12 12 12 12 12 124

  1. LEG NOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD NOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD PROBE 610 UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UC 610UC 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:39 Component: S/G A Page 58 of 73 Component: S/G A Page 58 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY:

QueryMl, Enc. 2 Page 58 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 109 64 0.13 109 66 0.12 0.12 109 68 0.54 0.53 0.39 0.48 109 70 0.13 0.11 0.14 0.33 0.15 109 72 0.16 0.39 109 74 0.17 0.49 0.66 109 76 0.26 0.54 0.26 0.40 0.28 109 78 0.19 0.51 0.22 109 80 0.32 0.61 0.45 0.55 0.33 109 82 0.31 0.67 0.64 0.60 109 84 0.32 0.64 0.46 109 86 0.21 0.54 109 88 0.41 0.24 0.19 0.23 0.36 109 90 0.15 0.52 0.18 109 92 0.19 0.15 0.20 109 94 0.47 0.08 0.21 0.48 0.09 109 96 0.38 0.16 109 98 0.10 0.44 0.15 0.24 109 100 0.51 0.60 0.70 0.24 0.12 109 102 0.23 0.64 0.15 0.13 0.13 109 104 0.13 0.25 0.12 0.23 0.22 109 106 0.15 110 45 0.17 110 65 0.16 110 67 0.12 DEG 113 133 121 120 119 123 ill 123 137 131 126 133 123 107 98 119 115 99 110 ill 116 102 104 103 107 105 117 119 109 115 96 114 107 113 123 122 118 132 123 134 128 128 124 131 138 124 130 138 125 139 120 155 121 123 138 125 127 67 126 127 136 132 129 128 130 132 116 129 147 153 153 138 145 155 141 133 136 131 125 140 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWD 5 TWD 5 TWD 5 TWD 17 TWD 17 TWD 14 TWD 16 TWD 5 TWD 5 TWD 6 TWD 12 TWD 6 TWD 6 TWD 13 TWD 7 TWD 16 TWD 19 TWD 10 TWD 17 TWD 10 TWD 14 TWD 10 TWD 7 TWD 16 TWD 8 TWD 11 TWD 18 TWD 15 TWD 17 TWD 12 TWD 11 TWD 19 TWD 19 TWD 18 TWD 12 TWD 19 TWD 15 TWD 8 TWD 17 TWD 14 TWD 9 TWD 7 TWD 9 TWD 12 TWD 6 TWD 17 TWD 7 TWD 7 TWD 6 TWD 8 TWD 15 TWD 4 TWD 8 TWD 16 TWD 4 TWD 13 TWD 6 TWD 4 TWD 15 TWD 6 TWD 9 TWD 16 TWD 17 TWD 19 TWD 9 TWD 5 TWD 8 TWD 18 TWD 6 TWD 5 TWD 5 TWD 5 TWD 9 TWD 5 TWD 8 TWD 8 TWD 6 TWD 7 TWD 7 TWD 5 LOCATION AV4

+0.00 AV3

+0.00 AV5

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AVI

+0.00 AV2

+0.00 AV3

+0.00 AV6

+0.00 AV7

+0.00 AV2

+0.00 AV4

+0.37 AV3

+0.00 AV4

+0.00 AV7

+0.00 AV2

+0.31 AV3

+0.00 AV5

+0.40 AV6

+0.00 AV7

+0.00 AVI

+0.00 AV4

-0.13 AV7

+0.00 AVI

+0.00 AV3

+0.00 AV4

+0.38 AV7

-0.26 AV8

+0.00 AVI

+0.00 AV4

+0.38 AV6

-0.15 AV7

+0.29 AVI

+0.13 AV4

+0.00 AV6

+0.07 AVI

+0.00 AV8

+0.00 AV5

+0.00 AV8

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AVI

+0.00 AV2

+0.00 AV8

+0.00 AV2

+0.00 AV5

+0.00 AV8

+0.00 AV2

+0.00 AVI

+0.00 AV3

+0.00 AV6

+0.00 AV7

+0.00 AV4

+0.00 AV5

+0.00 AV2

+0.00 AV3

+0.00 AV5

+0.00 AV6

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV8

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV2

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV3

+0.00 AV5

+0.00 AV4

+0.00 AV2

+0.00 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC UTIL 1

UTIL 2

CAL #

4 4

4 4

4 4

4 4

4 4

4 4

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

1 1

1 16 16 16 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 6

3 3

LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT NOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD PROBE 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 61OUL 610UL 61OUL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:39 Component: S/G A Page 59 of 73 Component: S/C A Page 59 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 59 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 110 69 0.14 0.14 0.58 0.34 110 71 0.55 0.42 110 73 0.12 0.62 0.49 0.28 110 75 0.22 0.38 110 77 0.23 0.36 0.65 0.23 110 79 0.27 0.28 0.29 0.18 0.29 0.21 0.14 110 81 0.14 0.51 0.41 110 83 0.22 0.40 110 87 0.17 0.52 110 89 0.20 0.15 0.50 0.54 0.21 110 91 0.38 110 95 0.32 0.40 0.24 110 97 0.17 110 99 0.28 0.31 110 103 0.14 0.38 0.14 0.19 110 109 0.13 0.12 0.14 110 123 0.16 111 46 0.10 111 68 0.24 Il1 70 0.13 0.15 0.19 111 72 0.17 0.24 0.59 111 74 0.38 0.30 0.26 111 76 0.30 0.56 0.32 111 78 0.45 0.36 111 80 0.52 0.37 0.48 111 82 0.34 0.31 0.56 Il1 84 0.30 I11 86 0.18 0.26 0.40 11 90 0.51 11 92 0.52 0.35 111 94 0.13 DEG CHN 144 P2 141 P2 126 P2 132 P2 128 P2 129 P2 122 P2 119 P2 123 P2 119 P2 127 P2 133 P2 107 P2 115 P2 112 P2 120 P2 130 P2 121 P2 127 P2 123 P2 126 P2 140 P2 138 P2 146 P2 130 P2 121 P2 91 P2 111 P2

'92 P2 107 P2 124 P2 113 P2 114 P2 112 P2 112 P2 97 P2 97 P2 96 P2 107 P2 111 P2 93 P2 110 P2 127 P2 97 P2 66 P2 95 P2 144 P2 148 P2 142 P2 144 P2 117 P2 127 P2 122 P2 137 P2 123 P2 122 P2 123 P2 122 P2 121 P2 134 P2 121 P2 135 P2 126 P2 132 P2 126 P2 128 P2 127 P2 125 P2 129 P2 113 P2 127 P2 119 P2 106 P2 119 P2 112 P2 115 P2 105 P2 114 P2 105 P2 99 P2 IND %TW TWD 6 TWD 6 TWD 18 TWD 12 TWD 17 TWD 14 TWD 5 TWD 19 TWO 16 TWD 10 TWD 9 TWD 13 TWD 9 TWD 13.

TWD 19 TWD 9 TWD 10 TWD 11 TWD 11 TWD 7 TWD 11 TWD 8 TWD 6 TWD 6 TWD 17 TWD 14 TWD 9 TWD 14 TWD 8 TWD 19 TWD 9 TWD 7 TWD 18 TWD 19 TWD 10 TWD 15 TWD 13 TWD 15 TWD 10 TWD 8 TWD 12 TWD 13 TWD 7 TWD 16 TWD 7 TWD 10 TWD 5 TWD 5 TWD 6 TWD 6 TWD 4 TWD 9 TWD 5 TWD 6 TWD 8 TWD 7 TWD 9 TWD 18 TWD 13 TWD 11 TWD 10 TWD 11 TWD 18 TWD 12 TWD 15 TWD 13 TWD 17 TWD 13 TWD 16 TWD 12 TWD 11 TWD 18 TWD 11 TWD 8 TWD 11 TWD 16 TWD 18 TWD 18 TWD 14 TWD 6 LOCATION AV2

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV4

+0.00 AV5

+0.00 AVI

+0.02 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV4

+0.04 AV5

+0.07 AV2

+0.00 AV5

+0.00 AV6

+0.00 AV8

+0.00 AV2

+0.11 AV3

+0.09 AV4

+0.13 AV5

+0.13 AV6

-0.09 AV7

+0.02 AV8

+0.04 AV3

+0.11 AV4

+0.07 AV6

+0.11 AVi

+0.31 AV2

+0.33 AVI

+0.00 AV2

+0.00 AV8

+0.00 AV7

+0.00 AV6

+0.00 AV2

+0.00 AVi

+0.00 AV7

+0.00 AV5

+0.00 AV4

+0.00 AVI

+0.00 AV6

+0.00 AV4

+0.00 AV3

+0.00 AVl

+0.00 AV2

+0.00 AV5

+0.00 AV6

+0.00 AV3

+0.00 AV4

+0.00 AVS

+0.00 AV2

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV4

+0.00 AV5

+0.07 AV6

+0.00 AV4

+0.09 AV5

+0.15 AV6

+0.07 AV2

+0.13 AV7

+0.07 AV4

+0.07 AV6

+0.02 AV7

-0.07 AV3

+0.13 AV6

+0.09 AV7

+0.13 AVI

-0.18 AV8

+0.00 AV7

+0.00 AVI

+0.00 AV2

+0.00 AV7

+0.00 AVI

+0.00 AV8

+0.00 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL #

3 3

3 3

3 3

1 1

1 1

1 1

2 2

2 2

1 1

1 1

1 1

1 1

1 1

2 2

15 15 15 15 15 15 15 13 13 13 13 13 13 13 11 11 11 11 12 12 12 8

1 3

3 3

3 1

1 15 1

1 1

1 1

1 1

1 1

1 1

1 1

2 15 15 15 13 13 13 13 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 6100L 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610DL 610UL 61OUL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:39 Component: S/G A Page 60 of 73 Component: S/C A Page 60 of 73 Bobbin AVE Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 60 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.24 0.45 0.46 0.21 111 96 0.41 il1 98 0.15 0.13 111 102 0.19 0.19 0.18 0.21 0.29 111 104 0.14 0.22 111 110 0.06 112 51 0.14 112 53 0.10 0.08 112 55 0.08 112 57 0.10 112 61 0.15 112 63 0.12 112 67 0.16 112 69 0.14 0.23 112 71 0.12 0.12 112 73 0.20 0.22 112 75 0.18 0.17 0.15 0.18 0.18 112 77 0.28 0.21 0.55 112 79 0.59 0.50 0.39 0.46 0.36 112 81 0.20 0.47 0.56 112 83 0.27 0.14 112 85 0.29 0.63 0.64 0.33 112 87 0.15 0.25 112 89 0.24 112 91 0.28 0.39 0.44 112 93 0.49 0.47 0.39 112 95 0.13 0.16 0.21 0.44 0.39 112 97 0.36 0.65 0.39 0.13 112 99 0.34 112 101 0.17 0.34 112 103 0.25 0.62 0.21 0.36 0.12 112 105 0.16 112 107 0.22 113 56 0.11 DEG CHN 115 P2 112 P2 107 P2 106 P2 118 P2 107 P2 94 P2 87 P2 97 P2 89 P2 101 P2 102 P2 108 P2 119 P2 70 P2 132 P2 145 P2 126 P2 155 P2 151 P2 130 P2 131 P2 140 P2 130 P2 134 P2 112 P2 124 P2 114 P2 83 P2 102 P2 119 P2 105 P2 107 P2 107 P2 129 P2 130 P2 119 P2 116 P2 108 P2 114 P2 110 P2 116 P2 110 P2 109 P2 113 P2 122 P2 143 P2 109 P2 126 P2 116 P2 120 P2 128 P2 122 P2 128 P2 121 P2 122 P2 132 P2 124 P2 128 P2 128 P2 80 P2 146 P2 135 P2 124 P2 128 P2 124 P2 118 P2 122 P2 136 P2 132 P2 136 P2 130 P2 130 P2 122 P2 134 P2 137 P2 144 P2 141 P2 140 P2 145 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW 10 17 17 9

16 7

6 9

9 9

10 13 7

11 4

5 5

4 4

4 6

5 7

6 9

5 5

8 8

7 7

6 7

7 10 8

18 18 16 13 15 12 8

15 17 10 6

19 19 19 12 6

10 9

10 13 15 16 15 13 5

6 8

15 13 13 19 13 5

12 6

11 9

18 8

12 5

6 8

5 LOCATION AV7

+0.00 AV4

+0.00 AV2

+0.00 AVI

+0.00 AV5

+0.00 AV5

+0.00 AVI

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AVI

+0.00 AV4

+0.00 AV3

+0.00 AV2

-0.02 AV5

+0.00 AV4

+0.00 AV5

+0.00 AV3

+0.00 AV2

-0.02 AVS

+0.00 AV2

+0.00 AV3

+0.00 AV3

+0.00 AV6

+0.00 AV3

+0.00 AV4

+0.00 AV3

+0.00 AV5

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV7

+0.00 AV4

+0.09 AV5

+0.09 AV6

-0.02 AV2

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV2

+0.31 AV3

+0.29 AV4

-0.22 AV2

+0.13 AV8

+0.11 AVl

+0.13 AV2

+0.13 AV6

+0.13 AVG

+0.09 AVI

+0.00 AV8

+0.00 AV8

+0.00 AVI

+0.00 AV5

+0.00 AV7

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AVl

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV7

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV5

+0.04 AV3

+0.00 AV2

+0.00 EXT EXT UTIL 1

UTIL TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC 2

CAL #

13 13 13 13 13 13 13 11 11 11 11 11 11 11 11 5

6 6

6 5

4 4

4 4

4 4

4 2

2 2

2 2

2 1

1 1

2 2

2 2

2 2

1 1

1 1

1 1

16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 12 12 12 12 12 12 12 12 12 6

LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD PROBE 61OUL 61OUL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:39 Component: S/G A Page 61 of 73 Component: S/C A Page 61 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 61 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.10 113 62 0.13 113 70 0.16 113 72 0.27 0.39 0.55 0.25 0.50 113 74 0.29 0.49 0.23 0.19 113 76 0.26.

0.28 0.29 113 78 0.38 0.39 0.64 0.25 113 80 0.45 0.66 0.57 0.16 0.62 113 82 0.48 0.59 0.60 0.14 113 84 0.58 113 86 0.53 0.45 113 88 0.18 0.10 113 90 0.26 113 92 0.24 0.52 113 94 0.16 0.23 0.13 0.20 0.09 0.10 113 96 0.15 0.22 113 98 0.26 113 100 0.29 0.12 113 102 0.36 0.32 0.18 113 104 0.13 0.37 0.36 0.52 0.24 113 124 0.18 114 41 0.15 114 59 0.14 114 71 0.11 0.20 114 73 0.23 0.12 0.64 0.41 114 75 0.19 0.27 0.13 114 77 0.31 0.47 0.28 0.25 114 79 0.27 0.58 0.45 0.40 0.29 114 81 0.50 0.47 0.22 0.16 DEG 122 124 120 118 108 113 107 106 ill 121 107 89 106 110 109 102 103 112 93

.109 105 103 112 104 117 104 108 106 125 125 115 93 148 131 125 129 107 128 140 119 155 137 118 128 128 135 150 135 134 147 148 127 135 121 134 141 143 147 142 130 130 135 122 120 121 134 128 113 116 ill 94 124 119 130 122 126 129 130 136 127 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 22 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW 5

5 6

10 13 17 9

16 11 16 9

7 10 10 11 13 13 19 9

15 19 17 6

18 16 18 18 6

18 16 15 8

5 10 9

17 7

9 5

8 4

4 6

8 10 10 5

12 11 7

5 12 12 16 9

7 6

6 5

8 9

5 19 14 8

10 5

1i 15 10 9

10 18 15 14 11 16 16 8

7 LOCATION AV3

+0.00 AV3

+0.00 AV3

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.33 AV2

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV2

+0.00 AV4

+0.02 AV6

+0.00 AV2

+0.00 AV3

+0.29 AV6

+0.35 AV8

+0.00 AV2

+0.33 AV3

+0.29 AV4

+0.31 AV5

-0.13 AV7

-0.24 AV2

+0.00 AV4

+0.33 AV7

+0.26 AVI

-0.02 AV8

+0.13 AVI

+0.00 AV3

+0.00 AV2

+0.00 AVI

+0.00 AV2

+0.00 AVI

+0.00 AV5

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

-0.20 AV7

-0.13 AVI

+0.00 AV2

-0.26 AV3

+0.00 AV5

+0.00 AV4

+0.00 AVI

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV7

+0.00 AV5

+0.00 AV4

+0.00 AV2

+0.00 AVI

+0.00 AV4

+0.00 AV5

+0.00 AV5

+0.00 AV4

+0.00 AV5

+0.00 AV7

+0.00 AV1

+0.07 AV2

+0.04 AV5

+0.00 AV3

+0.09 AV5

+0.00 AV7

+0.00 AV2

+0.04 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV3

+0.07 AV4

+0.02 AV5

+0.07 AV6

+0.00 AV7

+0.02 AV2

+0.11 AV4

+0.04 AV5

+0.09 AV6

+0.15 EXT EXT UTIL 1

UTIL TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 2

CAL #

6 4

4 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

1 16 16 15 15 14 14 14 14 14 14 14 14 14 14 14 14 12 12 12 12 12 12 12 12 12 12 8

7 6

3 3

1 1

1 1

1 1

.1 2

2 2

2 1

1 1

1 1

1 1

1 1

LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:40 Component: S/G A Page 62 of 73 Component: S/G A Page 62 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 62 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.14 114 83 0.28 114 85 0.26 114 87 0.34 0.48 0.53 114 89 0.18 114 91 0.36 0.52 114 93 0.25 0.31 0.29 0.40 114 95 0.13 0.13 0.34 114 97 0.26 0.12 0.27 114 101 0.19 114 107 0.13 114 125 0.12 0.12 115 40 0.14 0.18 115 48 0.17 115 58 0.10 0.12 115 68 0.38 0.45 115 70 0.26 0.15 0.24 0.12 0.15 115 72 0.11 0.39 115 74 0.27 0.20 0.12 0.13 115 78 0.48 0.52 0.31 0.31 115 80 0.12 0.12 0.32 115 82 0.30 0.61 0.23 0.16 115 86 0.15 0.41 0.35 115 88 0.25 0.68 115 90 0.57 0.20 0.09 115 92 0.32 0.51 0.49 0.57 115 94 0.20 0.14 115 96 0.17 0.14 0.35 0.26 0.22 0.16 115 102 0.19 0.19 0.49 0.31 115 104 0.14 115 126 0.20 115 130 0.17 0.18 DEG CHN 135 P2 117 P2 111 P2 111 P2 107 P2 111 P2 87 P2 100 P2 103 P2 99 P2 92 P2 110 P2 109 P2 88 P2 115 P2 106 P2 84 P2 107 P2 91 P2 85 P2 94 P2 145 P2 142 P2 88 P2 86 P2 142 P2 140 P2 149 P2 117 P2 114 P2 128 P2 123 P2 130 P2 110 P2 132 P2 129 P2 130 P2 126 P2 138 P2 146 P2 127 P2 125 P2 127 P2 126 P2 127 P2 147 P2 127 P2 130 P2 126 P2 121 P2 138 P2 137 P2 104 P2 93 P2 99 P2 129 P2 124 P2 107 P2 70 P2 81 P2 111 P2 105 P2 106 P2 116 P2 94 P2 66 P2 110 P2 71 P2 104 P2 111 P2 98 P2 73 P2 107 P2 102 P2 110 P2 105 P2 117 P2 119 P2 115 P2 117 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWO TWD TWO TWO TWO TWD TWO TWO TWD TWD TWO TWO TWD TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO TWO TWD TWO TWD TWD TWD TWD TWD TWD TWD TWO TWD TWD TWD TWD TWO TWO TWO TWO TWO TWO

%TW 6

10 10 14 18 19 8

14 18 11 13 12 15 6

6 14 11 6

11 10 7

5 5

6 7

6 4

5 13 15 10 6

9 5

6 5

14 10 8

5 5

16 17 11 11 5

5 12 11 19 9

7 7

16 14 9

19 19 9

4 13 18 18 19 9

7 8

7 14 11 10 7

10 10 19 14 7

9 8

8 LOCATION EXT EXT AV7

+0.18 TEN TEC AVI

+0.29 TEN TEC AV2

+0.09 TEN TEC AV7

+0.00 TEC TEH AV6

+0.00 TEC TEN AV2

+0.00 TEC TEN AVI

+0.00 TEC TEH AV8

+0.00 TEC TEN AV2

+0.00 TEC TEH AV6

+0.09 TEC TEH AV4

+0.00 TEC TEN AV3

+0.00 TEC TEN AV2

+0.00 TEC TEN AV7

+0.00 TEC TEH AV5

+0.00 TEC TEH AV3

+0.00 TEC TEN AV5

+0.00 TEC TEN AV4

+0.00 TEC TEN AV3

+0.00 TEC TEN AV5

+0.00 TEC TEH AV4

+0.00 TEC TEN AV4

+0.00 TEC TEN AV2

+0.00 TEC TEH AV8

+0.39 TEN TEC AV2

+0.11 TEN TEC AV5

+0.00 TEN TEC AV2

+0.00 TEN TEC AV3

+0.04 TEN TEC AV2

+0.00 TEN TEC AV3

+0.00 TEN TEC AV5

+0.00 TEN TEC AV6

+0.00 TEN TEC AV2

+0.00 TEN TEC AV3

+0.00 TEN TEC AV4

+0.00 TEN TEC AV2

+0.00 TEN TEC AV6

+0.00 TEN TEC AVl

+0.00 TEN TEC AV4

+0.00 TEN TEC AV6

+0.00 TEN TEC AV7

+0.00 TEN TEC AV2

+0.11 TEN TEC AV4

+0.11 TEN TEC AV5

+0.11 TEN TEC AV6

+0.04 TEN TEC AV2

+0.07 TEN TEC AV3

+0.09 TEN TEC AV7

-0.07 TEH TEC AV2

+0.07 TEN TEC AV6

+0.04 TEN TEC AV7

-0.02 TEN TEC AV8

-0.11 TEN TEC AV8

+0.00 TEC TEN AV3

+0.00 TEC TEN AVl

+0.00 TEC TEN AVI

+0.00 TEC TEN AV4

+0.00 TEC TEN AV7

-0.04 TEC TEN AVI

+0.00 TEC TEN AV8

+0.09 TEC TEN AV7

+0.00 TEC TEN AV6

+0.00 TEC TEN AV3

+0.00 TEC TEN AV2

+0.00 TEC TEN AV6

-0.20 TEC TEN AV3

-0.26 TEC TEN AV6

+0.00 TEC TEN AV5

+0.00 TEC TEH AV4

+0.00 TEC TEN AV3

+0.00 TEC TEN AV2

+0.00 TEC TEH AVl

+0.00 TEC TEN AV5

+0.00 TEC TEN AV4

+0.00 TEC TEH AV2

+0.00 TEC TEN AVI

+0.00 TEC TEH AV6

+0.00 TEC TEH AV4

+0.02 TEC TEN AV7

-0.04 TEC TEH AV4

-0.04 TEC TEN UTIL 1

UTIL 2

CAL #

12 1

15 15 15 15 13 13 13 13 13 13 13 13 13 13 13 13 11 11 8

8 57 57 5

5 5

3 3

3 3

3 3

3 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

15 15 15 16 16 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 11 11 11 11 11 7

7 7

LEG COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UC 610UC 610UL 610UL 610UL 61OUL 61OUL 61OUL 61OUL 610UL 61OUL 610UL 61OUL

61OUL, 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TDL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:40 Component: S/G A Page 63 of 73 Component: S/S A Page 63 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 63 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 116 61 0.15 0.16 0.11 116 73 0.19 116 75 0.29 0.22 0.18 116 77 0.24 0.21 0.14 116 79 0.41 116 81 0.30 0.19 116 85 0.42 116 87 0.55 0.40 0.09 0.21 116 89 0.15 0.52 116 91 0.21 0.25 0.47 0.19 116 93 0.16 0.32 0,.

11 0.24 0.35 116 95 0.53 0.14 0.57 0.30 116 97 0.10 0.17 116 129 0.13 0.22 0.15 117 44 0.24 117 46 0.18 117 58 0.20 117 64 0.18 117 68 0.20 117 70 0.14 0.33 0.16 117 76 0.17 117 78 0.58 0.34 0.48 0.28 117 80 0.31 0.62 0.40 0.28 0.17 117 82 0.31 117 86 0.64 0.10' 0.20 0.12 117 88 0.38 0.48 0.47 117 90 0.20 0.15 0.54 117 92 0.64 0.30 0.53 0.32 0.11 117 94 0.10 0.12 0.32 0.21 117 98 0.19 0.18 118 73 0.23 118 77 0.12 DEG CHN

==1

=

111 P2 122 P2 112 P2 102 P2 107 P2 118 P2 81 P2 134 P2 103 P2 128 P2 109 P2 118 P2 106 P2 100 P2 124 P2 127 P2 159 P2 137 P2 140 P2 126 P2 129 P2 128 P2 120 P2 132 P2 122 P2 121 P2 144 P2 113 P2 124 P2 121 P2 142 P2 126 P2 130 P2 153 P2 105 P2 110 P2 96 P2 86 P2 132 P2 129 P2 117 P2 100 P2 124 P2 117 P2 115 P2 93 P2 115 P2 110 P2 106 P2 110 P2 114 P2 104 P2 107 P2 102 P2 98 P2 85 P2 102 P2 107 P2 151 P2 128 P2 129 P2 104 P2 104 P2 113 P2 134 P2 128 P2 123 P2 123 P2 126 P2 127 P2 124 P2 131 P2 146 P2 107 P2 135 P2 132 P2 128 P2 141 P2 117 P2 136 P2 IND %TW TWO 6 TWO 6 TWO 5 TWO 7 TWD 11 TWD 8 TWO 7 TWD 9 TWD 8 TWD 6 TWD 14 TWD 11 TWD 7 TWD 14 TWD 17 TWD 14 TWD 4 TWD 8 TWD 6 TWD 16 TWO 8 TWO 10 TWD 15 TWD 8 TWO 6 TWO 12 TWD 5 TWD 9 TWD 12 TWD 17 TWD 6 TWD 17 TWD 11 TWD 4 TWO 7 TWO 6 TWD 10 TWO 7 TWO 10 TWO 8 TWD 8 TWD 7 TWD 8 TWD 6 TWD 12 TWD 7 TWD 7 TWD 18 TWD 12 TWO 16 TWO 10 TWO 11 TWD 18 TWD 14 TWD 10 TWD 7 TWD 11 TWD 19 TWO 4 TWO 8 TWD 5 TWO 15 TWD 18 TWD 17 TWD 8 TWD 6 TWD 17 TWD 19 TWD 11 TWD 17 TWD 12 TWO 5 TWO 4 TWD 5 TWD 12 TWD 8 TWD 7 TWD 7 TWO 9 TWD 5 LOCATION AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.22 AV2

+0.00 AV3

+0.00 AV5

+0.07 AV5

+0.02 AV6

-0.09 AV7

-0.09 AV4

+0.00 AV2

+0.29 AV7

+0.00 AV1

+0.29 AV7

+0.00 AV8

+0.00 AVl

+0.00 AV2

+0.00 AVI

+0.00 AV8

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV7

+0.00 AVl

+0.00 AV2

+0.00 AV4

+0.00 AV6

+0.00 AV7

+0.00 AV3

+0.00 AV4

+0.00 AV6

+0.00 AV7

+0.00 AV2

+0.00 AV3

+0.00 AV7

-0.07 AV5

-0.13 AV4

-0.11 AV5

+0.00 AV6

+0.00 AV5

+0.00 AV6

+0.00 AV2

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV6

+0.00 AV2

+0.00 AV5

+0.00 AV7

+0.26 AV8

+0.00 AV2

-0.20 AV5

+0.00 AV7

-0.22 AV8

+0.00 AV3

+0.04 AVI

+0.00 AV3

+0.00 AV7

+0.00 AV8

+0.00 AVi

+0.00 AV7

+0.00 AV3

+0.00 AV2

+0.00 AV8

+0.00 AVI

+0.00 AV2

+0.00 AV3

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AVI

+0.00 AV2

+0.00 AV3

-0.24 AV4

+0.00 AV7

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AVI

+0.04 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC UTIL 1

UTIL 2

CAL 4

4 4

2 2

2 2

1 1

1 2

22 16 16 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 7

7 7

8 6

6 4

4 4

4 4

2 2

2 2

2 2

2 2

22 2

16 16 16 16 15 15 15 14 14 14 14 14 14 14 14 14 14 14 14 14 14 1

1

  1. LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD PROBE 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610OL 610UL 610UL 610UL 610UL 610UL 610UL 610DL 610UL 610OL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 6100L 610DL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 6100L 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:40 Component: S/G A Page 64 of 73 Bobbin AVB Wear Indications 1% to 19%

Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl Aftachment 1, Enc. 2 Page 64 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.35 0.14 0.29 0.35 0.27 0.20 118 79 0.20 118 81 0.15 0.21 0.24 0.17 118 83 0.43 0.11 118 87 0.20 0.17 118 89 0.41 0.29 118 91 0.21 0.15 0.52 118 93 0.26 0.38 0.38 0.29 118 95 0.13 0.23 0.45 0.12 118 127 0.16 0.16 0.21 119 54 0.08 119 72 0.16 0.26 0.35 0.32 119 74 0.12 0.18 119 76 0.17 119 78 0.12 0.12 119 80 0.18 0.13 0.32 0.19 0.24 119 82 0.39 0.36 0.20 119 88 0.23 0.10 0.68 0.14 0.50 0.45 0.11 119 90 0.43 0.28 119 94 0.10 0.18 119 96 0.19 0.22 0.17 0.35 0.23 119 100 0.18 0.22 0.27 119 102 0.42 0.13 0.11 119 122 0.17 120 73 0.18 120 79 0.46 0.16 120 81 0.21 0.16 0.64 0.30 120 83 0.20 DEG 126 127 130 125 129 133 134 135 116 135 134 118 129 133 88 122 1il 103 95 113 103 108 102 118 75 115 1il 64 106 108 116 113 141 97 125 119 138 128 147 119 136 130 142 132 131 143 128 129 140 119 141 125 137 124 128 145 98 101 108 79 110 112 107 105 98 103 117 120 121 100 52 110 108 107 100 89 71 107 108 115 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW LOCATION 12 AV2

+0.11 6

AV3

+0.15 11 AV4

+0.04 12 AVS

+0.04 10 AV6

+0.11 8

AV7

+0.04 8

AV6

-0.04 6

AV2

+0.11 8

AV3

+0.07 9

AV4

+0.07 7

AV7

+0.07 15 AV3

+0.04 5

AV8

+0.15 9

AV7

+0.00 8

AVI

+0.00 16 AV8

+0.00 12 AVI

+0.00 9

AV8

+0.00 7

AV7

+0.00 18 AV2

+0.00 11 AV7

+0.00 15 AV6

+0.00 15 AV5

+0.00 12 AV3

+0.00 6

AV6

+0.00 10 AV5

+0.00 17 AV4

+0.00 6

AV1

+0.00 8

AV7

-0.11 7

AV5

+0.00 9

AV2

-0.13 3

AV6

+0.00 6

AV2

+0.00 10 AV3

+0.00 12 AV4

+0.00 11 AV5

+0.00 5

AV2

+0.00 7

AV6

+0.00 7

AV4

+0.09 5

AV3

+0.00 5

AV8

+0.33 7

AV2

+0.11 5

AV4

-0.02 12 AV5

+0.04 8

AV7

+0.07 9

AV8

+0.02 14 AV2

+0.07 13 AV7

-0.07 8

AV8

+0.02 9

AVI

+0.00 4

AV2

+0.00 19 AV3

+0.00 6

AV5

+0.00 16 AV6

+0.00 15 AV7

+0.00 5

AV8

+0.00 16 AV5

+0.00 12 AVI

+0.00 5

AV3

-0.17 8

AV2

+0.00 8

AV5

+0.00 10 AV4

+0.00 8

AV3

+0.00 14 AV2

+0.00 10 AVI

+0.00 9

AV3

+0.00 11 AV4

+0.00 12 AV5

+0.00 17 AV4

+0.00 7

AV2

+0.00 6

AVl

+0.00 8

AV4

-0.02 7

AV6

+0.26 15 AV7

-0.22 6

AV3

+0.07 8

AV3

+0.26 6

AV4

-0.20 19 AV7

+0.00 11 AV8

+0.22 8

AVI

+0.07 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC UTIL 1

UTIL 2

CAL 1

1 1

1 1

1 1

1 1

1 1

1 1

15 15 15 15 13 13 13 13 13 13 13 13 13 13 13 7

7 7

5 3

3 3

3 1

1 1

1 1

1 1

1 1

1 1

1 1

16 16 16 16 16 16 16 13 13 13 13 13 13 13 13 13 11 11 11 1i 11 7

2 2

2 2

2 2

2 1

  1. LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD PROBE 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 61DUL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:40 Component: S/G A Page 65 of 73 Component: S/G A Page 65 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 65 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 120 87 0.20 0.45 0.36 120 89 0.11 0.57 0.21 120 91 0.55 0.49 0.67 0.18 0.21 120 93 0.47 0.46 0.54 0.08 0.37 0.56 0.53 120 97 0.15 0.19 120 99 0.22 0.49 0.18 120 103 0.29 0.14 0.27 0.27 120 105 0.12 0.12 120 123 0.15 0.21 121 78 0.17 0.36 121 80 0.22 0.17 121 82 0.28 0.20 0.31 0.15 0.17 121 84 0.12 0.58 121 86 0.54 121 88 0.24 0.52 0.35 121 90 0.21 0.34 0.56 0.11 121 92 0.13 0.28 0.14 121 94 0.14 0.42 0.55 0.38 0.10 121 102 0.37 122 75 0.11 122 79 0.21 0.22 0.18 0.18 0.18 122 81 0.11 0.16 0.12 0.53 0.45 0.47 0.27 122 83 0.47 0.28 122 85 0.64 0.51 0.23 122 87 0.20 0.43 0.40 DEG 128 128 132 131 119 126 118 119 124 125 132 126 128 120 137 125 120 126 137 123 136 115 130 138 144 141 140 153 147 108 127 115 il1 107 85 96 86 103 129 100 90 123 122 96 106 97 130 114 113 112 94 103 78 94 129 118 125 152 113 142 128 122 135 115 126 133 124 144 125 121 124 122 107 104 120 115 124 110 ill 108 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW 8

15 12 5

17 8

17 16 19 7

8 15 15 17 4

13 17 17 6

8 9

16 7

10 6

10 10 5

5 7

9 7

13 8

7 10 8

11 6

7 5

18 17 11 19 14 8

12 17 5

6 12 7

6 14 17 13 4

12 5

8 8

7 7

7 5

6 5

17 15 16 10 15 10 19 17 9

9 16 16 LOCATION AVl AV5 AV8 AVl AV7 AV8 AV2 AV3 AV4 AV6 AV7 AV6 AV7 AV8 AV5 AV2 AV3 AV4 AV2 AV5 AV2 AV3 AV4 AV2 AV3 AV4 AV5 AV5 AV4 AV6 AV3 AV4 AV6 AV6 AV5 AV3 AV4 AV7 AV2 AV8 AVI AV4 AV3 AV8 AV5 AVl AV AV2 AV5 AV7 AV8 AV5 AVl AV3 AV5 AV6 AV7 AV8 AV3 AV7 AV2 AV4 AV5 AV6 AV7 AV2 AV3 AV4 AV5 AV6 AV7 AV8 AV6 AVI AV2 AV6 AV8 AV8 AV7 AV5

+=0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.04

+0.00

+0.00

+0.35

+0.31

+0.07

+0.00

+0.00

+0.29

+0.00

+0.00

+0.07

+0.04

+0.00

-0.04

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

-0.26

+0.00

+0.00

+0.00

+0.00

+0.00

-0.13

+0.11

+0.09

+0.04

+0.04

+0.00

+0.13

+0.09

+0.04

+0.07

+0.00

+0.00

+0.02

+0.35

+0.00

+0.04

+0.09

+0.13

+0.00

+0.00

+0.00 EXT EXT TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEE TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEE TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEE TEC TEH TEC TEH UTIL 1

UTIL 2

CAL 16 16 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 12 12 12 12 12 12 7

7 2

2 2

2 2

2 2

2 2

1 1

16 15 15 15 14 14 14 14 13 13 13 14 14 14 14 14 12 1

1 1

1 1

1 1

1 1

1 1

1 1

2 2

1 1

1 15 15 15

  1. LEG NOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT NOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD NOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:41 Component: S/G A Page 66 of 73 Component: S/G A Page 66 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 66 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.38 0.11 0.17 122 89 0.37 0.21 122 91 0.15 0.23 0.45 0.16 122 95 0.15 122 101 0.23 123 54 0.18 0.08 123 72 0.14 0.32 0.17 0.15 0.29 123 74 0.16 0.17 123 78 0.12 123 80 0.11 0.19 0.13 0.20 123 82 0.31 123 84 0.37 0.17 123 86 0.39 123 88 0.25 0.43 0.39 0.18 123 90 0.46 0.29 0.54 0.24 123 92 0.15 0.27 0.49 0.23 0.40 0.57 123 94 0.41 0.34 0.30 0.23 0.17 0.22 123 96 0.13 123 104 0.20 0.12 0.13 123 106 0.10 0.16 124 55 0.23 0.17 124 63 0.17 0.22 0.24 124 69 0.22 0.34 0.15 0.28 124 71 0.12 0.23 0.19 0.14 0.17 124 73 0.22 0.26 0.17 124 77 0.31 124 79 0.18 0.19 124 81 0.50 0.46 0.18 124 83 0.64 0.55 DEG 102 131 131 113 77 102 94 109 110 75 ill 128 144 104 131 133 137 129 123 129 149 118 139 134 119 112 99 97 120 140 120 131 127 112 92 109 103 141 121 120 129 125 119 114 106 112 107 77 101 69 99 146 151 119 85 100 118 132 130 119 108 110 108 129 135 121 122 125 108 97 92 83 87 75 67 104 113 73 120 121 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 22 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWD 15 TWD 6 TWD 8 TWD 15 TWD 10 TWD 7 TWD 10 TWD 17 TWD 7 TWD 7 TWD 11 TWD 7 TWD 3 TWD 6 TWD 12 TWD 7 TWD 6 TWD 11 TWD 6 TWD 7 TWD 5 TWD 5 TWD 8 TWD 5 TWD 8 TWD 11 TWD 13 TWD 7 TWD 15 TWD 9 TWD 14 TWD 13 TWD 7 TWD 17 TWD 12 TWD 19 TWD 10 TWD 6 TWD 10 TWD 16 TWD 9 TWD 14 TWD 17 TWD 16 TWD 14 TWD 12 TWD 10 TWD 8 TWD 9 TWD 6 TWD 10 TWD 6 TWD 7 TWD 6 TWD 8 TWD 10 TWD 7 TWD 7 TWD 9 TWD 9 TWD 9 TWD 12 TWD 6 TWD 10 TWD 5 TWD 9 TWD 8 TWD 6 TWD 7 TWD 9 TWD 10 TWD 7 TWD 11 TWD 7 TWD 7 TWD 16 TWD 15 TWD 7 TWD 19 TWD 17 LOCATION AV4

+0.00 AV3

+0.00 AV2

+0.00 AV7

+0.00 AVI

+0.00 AV6

+0.00 AV3

+0.00 AV2

+0.00 AVI

+0.00 AV2

+0.00 AV4

+0.00 AV4

+0.00 AV6

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV7

+0.00 AV6

+0.00 AV6

+0.00 AV7

+0.11 AV3

+0.11 AV3

+0.02 AV5

+0.13 AV6

+0.00 AV8

+0.00 AVI

+0.07 AV3

+0.26 AV8

+0.33 AV7

+0.00 AV2

+0.00 AV4

+0.00 AV6

+0.00 AV7

+0.00 AV8

+0.00 AV5

+0.00 AV2

+0.00 AVI

+0.00 AVI

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

-0.20 AV2

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV6

+0.00 AV5

+0.00 AV6

+0.00 AV4

+0.00 AV5

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV7

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV7

+0.00 AV4

+0.00 AV5

+0.00 AV7

+0.15 AV7

+0.26 AV6

+0.00 AV7

+0.00 AV7

+0.00 AV8

+0.00 AVI

+0.00 AVi

+0.09 AV8

+0.15 EXT TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH EXT UTIL 1

UTIL 2

TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEN TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC CAL #

15 15 15 15 15 13 13 13 13 13 11 5

5 3

3 3

3 3

1 1

1 1

1 1

1 1

2 2

15 16 16 16 16 13 13 13 13 14 14 14 14 14 14 13 13 13 13 13 13 13 11 11 11 11 11 6

6 4

4 4

4 4

4 4

4 4

4 4

4 2

2 2

2 2

2 22 2

1 1

LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 6100L 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:41 Component: S/G A Page 67 of 73 Component: S/C A Page 67 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 67 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 124 85 0.12 0.44 0.17 124 87 0.29 0.11 0.47 0.38 0.15 124 89 0.50 0.49 0.41 124 91 0.56 0.13 0.14 124 93 0.49 124 95 0.30 0.27 124 99 0.14 0.20 0.15 0.25 124 105 0.12 125 50 0.14 125 68 0.16 125 72 0.52 125 74 0.33 0.21 0.28 125 76 0.25 0.39 0.19 125 80 0.17 0.54 0.54 125 82 0.19 0.52

0. 64 125 84 0.58 125 86 0.27 0.48 125 88 0.26 0.38 125 90 0.47 0.46 0.52 0.48 125 92 0.11 0.48 0.30 0.14 125 98 0.12 125 102 0.16 0.25 125 106 0.21 125 108 0.14 126 67 0.19 126 69 0.23 0.18 0.22 126 71 0.11 126 75 0.18 0.12 0.26 126 77 0.13 0.15 0.31 0.21 126 79 0.19 0.15 126 81 0.50 126 83 0.19 0.39 0.44 0.58 126 85 0.15 0.23 126 87 0.40 0.25 126 89 0.50 0.41 DEG CHN 77 P2 110 P2 85 P2 125 P2 124 P2 129 P2 130 P2 127 P2 125 P2 124 P2 127 P2 119 P2 142 P2 138 P2 121 P2 104 P2 116 P2 138 P2 122 P2 128 P2 136 P2 143 P2 147 P2 106 P2 114 P2 126 P2 118 P2 122 P2 94 P2 120 P2 102 P2 87 P2 103 P2 110 P2 103 P2 109 P2 112 P2 121 P2 124 P2 125 P2 98 P2 106 P2 122 P2 123 P2 123 P2 126 P2 118 P2 105 P2 104 P2 73 P2 149 P2 131 P2 125 P2 143 P2 159 P2 121 P2 133 P2 129 P2 97 P2 134 P2 124 P2 155 P2 138 P2 100 P2 131 P2 128 P2 117 P2 119 P2 142 P2 125 P2 81 P2 106 P2 112 P2 107 P2 108 P2 122 P2 128 P2 11 P2 109 P2 110 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW 5

15 7

11 5

15 13 6

16 16 14 17 5

6 16 11 10 6

8 6

9 5

6 6

17 12 8

10 9

13 7

7 17 17 7

16 19 18 10 15 11 15 15 15 17 16 5

17 12 7

5 6

9 8

5 7

9 7

8 5

7 5

10 5

6 11 8

8 6

16 7

13 15 18 6

9 16 11 18 16 LOCATION AVl

+0.00 AV3

+0.18 AV8

+0.02 AV2

+0.00 AV3

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV4

+0.00 AV5

+0.00 AV8

+0.00 AV3

+0.00 AV6

+0.00 AV7

+0.00 AV5

+0.00 AV3

+0.00 AV4

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV4

+0.00 AV7

+0.00 AV2

+0.00 AV6

+0.00 AV4

+0.00 AV5

+0.11 AV6

-0.13 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV2

+0.00 AV3

+0.33 AV4

+0.44 AV2

-0.18 AV3

-0.15 AV7

+0.37 AV6

+0.15 AV3

+0.00 AV7

+0.00 AV3

+0.00 AV2

+0.51 AV2

+0.00 AV3

+0.00 AV6

+0.00 AV7

+0.00 AV7

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV6

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV5

+0.00 AV7

+0.35 AV7

+0.00 AV4

+0.00 AV5

+0.00 AV7

-0.18 AV3

+0.00 AV4

+0.15 AV5

+0.07 AV8

+0.07 AV5

+0.00 AV7

-0.18 AV4

+0.02 AV3

-0.18 AV4

+0.24 AV6

+0.33 AV8

+0.00 AVl

+0.11 AV4

+0.13 AV7

+0.00 AV3

+0.00 AV8

+0.00 AVI

+0.00 EXT TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC EXT UTIL 1

UTIL 2

TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH CAL #

2 2

2 16 16 16 16 16 16 16 16 14 14 14 14 14 14 14 14 14 14 12 6

4 4

2 2

2 2

2 2

2 2

2 22 2

1 16 16 15 15 14 14 14 14 13 13 1313 14 12 12 12 12 3

3 3

3 3

1 1

1 1

1 1

1 1

1 1

2 2

2 2

1 1

15 15 1515 LEG COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT PROBE 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610DL 6100L 610UL 6100L 610UL 610UL 610UL 610UL 61OUL 61OUL 61OUL 610UL 6100L 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:41 Component: S/G A Page 68 of 73 Component: S/C A Page 68 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 68 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 126 91 0.39 0.42 0.31 0.10 126 93 0.21 0.11 0.22 126 95 0.18 0.23 0.33 126 97 0.25 0.23 0.37 126 99 0.11 126 103 0.17 0.16 126 105 0.15 0.38 126 109 0.14 127 52 0.15 127 68 0.27 0.15 127 70 0.13 127 76 0.15 0.23 0.20 127 78 0.39 0.23 0.45 0.45 127 82 0.13 0.57 127 84 0.62 127 86 0.42 0.35 0.18 127 88 0.16 0.50 0.50 0.56 127 90 0.50 0.50 0.51 0.39 0.30 127 92 0.16 0.41 0.18 127 94 0.15 0.13 0.16 127 96 0.25 0.31 0.24 0.10 0.24 127 100 0.16 127 102 0.14 0.12 128 67 0.13 0.43 0.56 0.46 128 73 0.37 0.22 128 79 0.17 128 81 0.38 0.42 0.29 128 85 0.43 0.19 0.12 128 87 0.62 0.53 0.40 0.50 0.32 0.15 128 89 0.11 0.27 DEG CHN 113 P2 100 P2 91 P2 109 P2 92 P2 72 P2 73 P2 128 P2 88 P2 109 P2 108 P2 89 P2 114 P2 97 P2 Il1 P2 100 P2 87 P2 112 P2 125 P2 101 P2 127 P2 131 P2 122 P2 140 P2 137 P2 129 P2 111 P2 129 P2 126 P2 116 P2 135 P2 125 P2 108 P2 107 P2 107 P2 68 P2 127 P2 122 P2 126 P2 121 P2 110 P2 110 P2 109 P2 109 P2 104 P2 107 P2 126 P2 137 P2 120 P2 112 P2 77 P2 104 P2 112 P2 94 P2 69 P2 94 P2 120 P2 125 P2 86 P2 120 P2 118 P2 124 P2 123 P2 101 P2 83 P2 90 P2 122 P2 113 P2 98 P2 123 P2 96 P2 70 P2 127 P2 119 P2 124 P2 116 P2 135 P2 137 P2 136 P2 127 P2 IND %TW TWD 15 TWD 16 TWD 13 TWD 5 TWD 9 TWD 5 TWD 10 TWD 8 TWD 10 TWD 13 TWD 11 TWD 10 TWD 14 TWD 5 TWD 8 TWD 8 TWD 8 TWD 16 TWD 6 TWD 6 TWD 10 TWD 6 TWD 5 TWD 6 TWD 9 TWD 8 TWD 14 TWD 9 TWD 15 TWD 15 TWD 5 TWD 18 TWD 18 TWD 16 TWD 14 TWD 8 TWD 6 TWD 16 TWD 16 TWD 17 TWD 18 TWD 18 TWD 18 TWD 15 TWD 12 TWD 7 TWD 14 TWD 7 TWD 7 TWD 6 TWD 7 TWD 11 TWD 12 TWD 10 TWD 5 TWD 10 TWD 7 TWD 7 TWD 6 TWD 5 TWD 15 TWD 18 TWD 15 TWD 13 TWD 8 TWD 7 TWD 13 TWD 14 TWD 11 TWD 14 TWD 7 TWD 5 TWD 18 TWD 17 TWD 14 TWD 16 TWD 12 TWD 6 TWD 5 TWD 10 LOCATION AV8

+0.00 AV4

+0.00 AV2

+0.00 AVI

+0.00 AV5

+0.00 AV4

+0.00 AV2

+0.00 AV8

+0.00 AV3

+0.00 AV2

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV5

+0.00 AV2

+0.00 AV3

+0.00 AV4

-0.11 AV3

+0.00 AV4

+0.00 AV4

-0.13 AVI

+0.00 AV7

+0.00 AV5

+0.00 AV4

+0.18 AV5

+0.13 AV6

+0.00 AV3

+0.18 AV4

+0.09 AV5

+0.13 AV8

+0.00 AV2

+0.07 AV3

+0.07 AV8

-0.13 AV8

+0.00 AV4

+0.00 AV2

+0.00 AVI

+0.00 AV2

+0.00 AV4

+0.00 AV5

+0.00 AV8

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AVI

+0.00 AVI

+0.00 AV6

+0.00 AV7

+0.00 AV6

-0.18 AV4

+0.00 AV3

-0.25 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AVI

+0.00 AV4

+0.00 AV4

+0.02 AV3

+0.00 AVI

+0.00 AV2

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.24 AV7

+0.15 AV7

-0.22 AV8

+0.00 AV2

+0.31 AV3

+0.00 AV2

-0.18 AV3

-0.22 AVI

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV6

+0.00 AV7

+0.00 AV8

+0.00 AVI

+0.00 AV2

+0.00 EXT TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC EXT UTIL 1

UTIL 2

TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH CAL #

13 13 13 13 13 13 13 13 13 13 13 13 13 13 11 11 11 11 12 6

3 3

3 1

1 1

1 1

1 1

1 1

2 15 15 15 16 16 16

.16 13 13 13 13 13 14 14 14 13 13 13 13 13 13 13 13 13 11 11 4

4 4

4 2

2 2

2 2

2 2

2 2

16 16 16 16 16 16 16 16 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UDL 610UL 610TDL 610UL 610UL 610UL 610UL 610UL 610TDL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610TDL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:42 Component: S/G A Page 69 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 69 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.31 0.60 128 91 0.51 128 93 0.16 0.26 0.56 0.35 0.38 128 95 0.14 0.53 0.25 128 99 0.20 0.12 0.17 0.31 128 101 0.16 0.15 0.15 128 103 0.15 128 107 0.13 128 117 0.29 0.18 129 66 0.20 0.24 0.60 129 74 0.36 0.28 129 80 0.54 0.66 0.40 0.63 0.31 129 82 0.58 0.61 0.16 129 86 0.30 0.39 0.14 129 88 0.14 0.20 0.48 0.25 0.16 0.12 0.13 129 90 0.11 0.19 0.54 0.46 0.30 0.47 129 92 0.16 0.15 129 94 0.23 0.19 0.10 129 96 0.13 129 98 0.23 129 104 0.23 0.12 0.15 129 106 0.12 130 67 0.27 0.18 0.53 130 69 0.15 130 71 0.12 0.16 130 73 0.25 130 75 0.11 0.14 0.12 130 79 0.12 0.23 0.25 0.19 130 81 0.22 0.36 0.60 0.51 DEG CHN 135 P2 122 P2 125 P2 127 P2 123 P2 127 P2 129 P2 125 P2 131 P2 123 P2 132 P2 113 P2 66 P2 129 P2 139 P2 134 P2 142 P2 142 P2 122 P2 138 P2 140 P2 136 P2 123 P2 128 P2 118 P2 105 P2 114 P2 107 P2 112 P2 99 P2 112 P2 110 P2 117 P2 107 P2 127 P2 136 P2 135 P2 137 P2 124 P2 96 P2 108 P2 99 P2 117 P2 107 P2 88 P2 120 P2 112 P2 125 P2 125 P2 137 P2 120 P2 88 P2 87 P2 131 P2 118 P2 113 P2 127 P2 133 P2 144 P2 143 P2 154 P2 155 P2 108 P2 117 P2 127 P2 130 P2 145 P2 131 P2 109 P2 126 P2 146 P2 123 P2 131 P2 130 P2 122 P2 138 P2 133 P2 122 P2 113 P2 120 P2 IND %TW TWD 11 TWD 18 TWD 16 TWD 7 TWD 10 TWD 17 TWD 13 TWD 13 TWD 6 TWD 17 TWD 9 TWD 8 TWD 5 TWD 7 TWD 11 TWD 6 TWD 6 TWD 6 TWD 6 TWD 5 TWD 12 TWD 8 TWD 8 TWD 9 TWD 18 TWD 13 TWD 10 TWD 17 TWD 19 TWD 14 TWD 19 TWD 11 TWD 18 TWD 18 TWD 6 TWD 11 TWD 13 TWD 6 TWD 7 TWD 9 TWD 18 TWD 11 TWD 8 TWD 6 TWD 6 TWD 5 TWD 8 TWD 17 TWD 15 TWD 11 TWD 15 TWD 7 TWD 7 TWD 9 TWD 8 TWD 4 TWD 5 TWD 9 TWD 8 TWD 5 TWD 6 TWD 5 TWD 10 TWD 7 TWD 17 TWD 6 TWD 5 TWD 6 TWD 10 TWD 5 TWD 6 TWD 5 TWD 5 TWD 9 TWD 10 TWD 8 TWD 8 TWD 13 TWD 19 TWD 17 LOCATION AV4

+0.00 AV8

+0.00 AV7

+0.00 AV2

+0.00 AV3

+0.00 AVS

+0.00 AV6

+0.00 AV6

+0.00 AV8

+o.0o AV2

+0.13 AV6

+0.00 AV7

+0.00 AV2

-0.26 AV3

-0.24 AV6

+0.00 AV7

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV2

+0.00 AV6

+0.00 AV7

+0.00 AV6

+0.00 AV3

+0.11 AV5

+0.11 AV6

+0.09 AV4

+0.00 AV5

+0.00 AV3

+0.00 AV4

+0.33 AV5

+0.00 AV7

-0.26 AV8

+0.00 AV2

+0.26 AV4

+0.00 AV8

+0.00 AV6

+0.00 AV7

+0.00 AV8

+0.00 AV8

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AVI

+0.00 AVI

+0.00 AV3

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV8

+0.00 AV5

+0.00 AVI

+0.00 AV2

+0.00 AV3

+0.00 AV5

+0.00 AVi

+0.00 AV5

+0.00 AV7

+0.07 AV6

-0.04 AV5

-0.13 AV5

-0.04 AVI

+0.00 AV7

+0.35 AV6

+0.00 AV5

+0.00 AV5

+0.00 AV6

+0.00 AV7

-0.13 AV4

+0.00 AV5

+0.02 AV7

-0.13 AV3

+0.11 AVS

+0.09 AV6

+0.02 AV7

-0.04 AV2

+0.04 AV4

+0.09 AVS

+0.13 AV6

+0.00 EXT EXT TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC UTIL 1

UTIL 2

CAL 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 12 12 12 12 12 10 10 4

4 4

2 2

2 2

2 2

2 22 16 16 16 15 15 15 15 15 15 15 14 14 14 14 14 14 13 13 14 14 14 14 14 12 12 12 12 3

3 3

3 3

3 1

1 11 1

1 1

1 1

1 1

1

  1. LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 61OUL 61OUL 61OUL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UJL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TDL 61OUL 610UL 610UL 610UL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TDL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:42 Component: S/G A Page 70 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 70 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 130 83 0.55 130 85 0.18 0.31 0.50 130 87 0.27 0.23 130 89 0.26 0.32 0.30 0.13 0.25 130 91 0.41 0.26 0.45 0.13 130 93 0.21 0.18 0.15 130 95 0.13 0.16 0.16 0.22 0.18 0.21 0.16 130 97 0.14 0.22 0.25 0.16 130 101 0.13 0.16 131 70 0.51 131 74 0.26 0.49 0.20 0.22 131 78 0.43 0.27 0.23 0.47 131 80 0.12 0.49 0.57 0.13 131 82 0.39 0.27 0.28 0.42 0.16 131 84 0.61 0.33 0.20 131 86 0.54 0.50 0.52 0.29 0.12 131 88 0.40 0.60 0.14 131 90 0.14 0.35 0.37 0.33 131 92 0.58 0.21 0.29 0.45 131 94 0.35 0.19 0.13 0.34 0.26 131 96 0.13 0.19 0.14 0.10 132 67 0.15 0.28 0.49 DEG CHN 123 P2 113 P2 119 P2 129 P2 127 P2 108 P2 127 P2 116 P2 113 P2 104 P2 89 P2 111 P2 103 P2 115 P2 111 P2 119 P2 119 P2 105 P2 121 P2 123 P2 107 P2 113 P2 100 P2 108 P2 80 P2 138 P2 105 P2 118 P2 101 P2 98 P2 112 P2 120 P2 124 P2 122 P2 139 P2 133 P2 122 P2 121 P2 128 P2 125 P2 137 P2 126 P2 127 P2 147 P2 123 P2 123 P2 122 P2 127 P2 148 P2 103 P2 103 P2 103 P2 105 P2 116 P2 108 P2 111 P2 71 P2 126 P2 125 P2 135 P2 102 P2 100 P2 111 P2 113 P2 114 P2 119 P2 124 P2 125 P2 96 P2 73 P2 98 P2 105 P2 98 P2 96 P2 95 P2 99 P2 90 P2 116 P2 125 P2 124 P2 IND %TW TWD 18 TWD 7 TWD 11 TWD 16 TWD 12 TWD 10 TWD 11 TWD 13 TWD 13 TWD 6 TWD 11 TWD 16 TWD 11 TWD 17 TWD 6 TWD 9 TWD 8 TWD 7 TWD 6 TWD 7 TWD 7 TWD 10 TWD 8 TWD 9 TWD 7 TWD 6 TWD 10 TWD 11 TWD 7 TWD 7 TWD 8 TWD 16 TWD 10 TWD 16 TWD 8 TWD 8 TWD 15 TWD 10 TWD 9 TWD 16 TWD 5 TWD 16 TWD 18 TWD 5 TWD 14 TWD 10 TWD 10 TWD 15 TWD 6 TWD 18 TWD 12 TWD 8 TWD 19 TWD 18 TWD 19 TWD 12 TWD 6 TWD 14 TWD 18 TWO 6 TWD 7 TWD 14 TWD 14 TWD 13 TWD 18 TWD 8 TWD 11 TWD 15 TWD 14 TWD 9 TWD 6 TWD 14 TWD 11 TWD 6 TWD 8 TWD 7 TWD 5 TWD 6 TWD 10 TWD 16 LOCATION AV2 AVI AV4 AV7 AV7 AV2 AV8 AV5 AV4 AV2 AVI AV8 AV7 AV6 AVI AV8 AV6 AV5 AV8 AV7 AV5 AV4 AV3 AV2 AVI AV6 AV3 AV2 AVI AV4 AV3 AV4 AV2 AV4 AV5 AV6 AV3 AV4 AV5 AV6 AV3 AV5 AV6 AV8 AV4 AV5 AV6 AV7 AV8 AV3 AV4 AV8 AV7 AV6 AV5 AV4 AVI AV3 AV5 AV6 AV8 AV7 AV2 AVl AV3 AV4 AV5 AV7 AV7 AV6 AV5 AV4 AV2 AV6 AV5 AV4 AV2 AV5 AV6 AV7

+0.00

+0.07

+0.17

+0.15

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

-0.24

-0.24

+0.00

+0.00

+0.00

+0.13

+0.15

+0.18

+0.11

+0.13

+0.15

+0.04

-0.02

+0.07

+0.07

+0.02

+0.07

+0.09

+0.04

+0.07

+0.15

+0.15

+0.28

-0.22

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

'0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.11

+0.00

+0.00

+0.00 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC UTIL 1

UTIL 2

CAL #

1 1

1 1

15 15 15 15 15 15 15 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 11 11 3

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 2

2 2

15 15 15 1S 15 16 16 16 13 13 13 13 14 14 14 14 13 13 13 13 13 13 13 13 13 4

4 4

LEG COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TDL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:43 Component: S/G A Page 71 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 71 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.19 132 69 0.33 0.59 0.33 0.13 132 73 0.13 0.16 132 75 0.18 0.15 132 79 0.28 0.27 0.41 0.36 132 81 0.26 0.56 0.35 0.33 132 83 0.45 132 85 0.16 132 87 0.10 0.10 0.10 0.31 0.55 0.31 132 89 0.29 0.57 0.30 132 91 0.10 0.64 0.25 0.10 132 93 0.24 0.36 0.24 0.17 0.34 132 97 0.12 132 99 0.12 0.16 132 103 0.12 0.18 0.17 133 68 0.18 0.62 0.44 0.24 0.22 0.20 133 70 0.13 0.36 133 72 0.26 133 74 0.18

,0.20 0.22 133 76 0.17 133 78 0.33 133 80 0.38 0.65 0.24 0.18 133 82 0.21 0.25 133 84 0.22 0.19 0.56 0.14 133 86 0.43 0.40 133 88 0.12 0.25 0.49 0.12 0.15 0.12 133 92 0.43 0.26 0.42 0.14 133 94 0.27 DEG 122 116 125 128 88 115 103 105 144 113 106 110 i11 102 ill 107 119 113 115 92 146 155 131 126 141 118 126 128 134 119 127 160 128 123 120 129 123 77 132 137 92 128 121 108 124 123 124 106 110 100 106 98 120 103 82 112 99 i1 109 110 115 100 118 120 126 125 139 132 131 94 113 102 107 127 123 105 98 110 115 127 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW LOCATION 7

AV8

+0.15 12 AV3

+0.00 18 AV6

+0.00 12 AV7

+0.00 5

AV5

+0.11 5

AV6

+0.00 6

AV7

+0.00 7

AV7

-0.13 6

AV8

-0.09 10 AV4

+0.24 10 AV5

+0.00 14 AV6

-0.24 13 AV7

-0.31 10 AV5

+0.31 17 AV6

+0.00 12 AV7

+0.37 12 AV8

+0.42 15 AV8

-0.11 6

AV6

+0.15 4

AV2

+0.00 4

AV3

+0.00 4

AV4

+0.00 11 AV5

+0.00 17 AV6

+0.00 11 AV7

+0.00 11 AVI

+0.00 17 AV3

+0.00 11 AV5

+0.00 4

AVI

+0.00 19 AV2

+0.00 9

AV5

+0.00 4

AV8

+0.00 9

AV2

+0.00 13 AV3

+0.00 9

AV4

+0.00 7

AV5

+0.00 12 AV6

+0.00 5

AV2

-0.26 5

AV4

+0.00 6

AV5

+0.00 6

AV2

+0.00 9

AV7

+0.00 8

AV8

+0.00 7

AVI

+0.00 19 AV2

+0.00 15 AV3

+0.00 9

AV6

+0.00 9

AV7

+0.00 8

AV8

+0.00 5

AV6

+0.00 13 AV7

+0.00 10 AV7

+0.24 7

AV6

-0.18 8

AV7

+0.00 8

AV8

+0.18 7

AV4

+0.00 12 AV5

+0.00 13 AV4

+0.33 19 AV5

+0.00 9

AV6

+0.00 7

AV3

+0.02 8

AVI

+0.00 9

AV8

+0.33 8

AV2

+0.09 8

AV3

+0.11 18 AV7

+0.11 6

AV8

+0.20 14 AV4

+0.00 13 AV6

+0.00 6

AV2

+0.00 11 AV7

+0.00 18 AV6

+0.00 6

AV5

+0.00 7

AV4

+0.00 6

AV3

+0.04 16 AV6

+0.00 11 AV5

+0.00 16 AV4

+0.00 7

AVI

+0.00 10 AV3

+0.00 EXT TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC EXT TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEN UTIL 1

UTIL 2

CAL #

4 4

4 4

4 2

2 2

2 2

2 2

2 2

2 2

2 2

2 16 16 16 16 16 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 11 11 11 4

4 4

4 4

4 4

4 4

2 2

2 2

2 2

2 2

2 2

2 1

1 1

1 16 16 15 15 15 15 15 15 13 13 13 13 14 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT NOT HOT PROBE 610UL 610UL 61OUL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610OL 610UL 610UL 610OL 610UL 610UL 610UL 610UL 610UL 610UL 610DL 610OL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610DL 610UL 610UL 610UL 61OUL 610OL 610UL 610OL 610UL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 610TUL 610UL 610UL 610UL 610UL 610UDL 610DL 610TUL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:43 Component: S/G A Page 72 of 73 Component: S/S A Page 72 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 72 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.25 0.19 0.20 133 96 0.52 0.55 133 102 0.12 134 67 0.13 0.19 0.11 0.12 134 69 0.11 134 73 0.28 0.36 0.17 0.20 0.16 0.25 134 75 0.16 0.22 134 79 0.26 0.26 0.35 134 81 0.20 0.68 0.30 134 83 0.37 0.56 0.16 134 85 0.17 0.31 0.14 0.14 0.35 134 87 0.35 0.54 0.71 0.14 0.13 0.25 134.

89 0.30 0.21 134 91 0.43 0.54 0.43 0.34 0.20 134 93 0.27 0.22 0.13 134 97 0.17 0.26 0.26 134 103 0.11 0.14 135 70 0.14 0.27 135 72 0.17 135 74 0.13 0.41 135 78 0.26 135 80 0.16 0.13 135 84 0.56 0.64 0.13 135 90 0.64 0.18 0.49 135 92 0.66 0.10 135 94 0.23 0.13 0.19 135 96 0.21 136 73 0.16 0.20 136 75 0.14 0.21 0.13 0.11 DEG 117 119 127 116 114 133 126 153 136 83 69 84 110 97 103 70 97 87 110 87 104 115 95 109 108 104 91 98 87 94 92 70 91 113 107 108 83 52 96 92 105 110 106 89 92 80 101 102 75 122 90 83 118 153 79 86 117 94 107 104 76 96 109 107 51 113 81 107 103 98 102 73 85 98 106 126 144 124 112 124 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW 9

7 8

17 17 5

6 8

5 5

5 10 12 6

7 6

9 6

8 9

9 12 7

19 10 12 17 6

6 11 6

5 12 12 16 19 5

5 9

10 8

14 16 14 11 7

10 8

5 6

9 9

5 6

6 10 7

5 13 9

6 5

17 18 5

18 7

15 19 4

8 5

7 8

7 8

6 8

5 5

LOCATION AV4

+0.00 AVS

+0.00 AV6

+0.00 AV3

+0.00 AV4

+0.00 AV7

+0.00 AV2

+0.00 AVS

+0.00 AV6

+0.00 AV7

+0.00 AV7

+0.15 AV7

+0.00 AV6

+0.00 AVS

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV6

+0.00 AVS

+0.00 AV6

+0.00 AVS

+0.00 AV4

+0.00 AV8

+0.00 AV7

+0.00 AV2

+0.00 AV6

+0.00 AVS

+0.00 AV4

+0.00 AV7

+0.00 AV6

+0.00 AVS

+0.00 AV4

+0.00 AV3

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV7

+0.00 AVG

+0.00 AV8

+0.00 AVS

+0.00 AV4

+0.00 AV2

+0.00 AVI

+0.00 AV5

+0.00 AV4

+0.00 AV2

+0.00 AV4

+0.00 AV2

-0.24 AVI

-0.07 AV4

+0.13 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV7

+0.20 AV5

+0.00 AV3

+0.00 AV4

+0.00 AV7

+0.00 AV2

-0.29 AV6

+0.00 AV4

+0.00 AVI

+0.00 AV4

+0.00 AVI

+0.00 AV6

+0.00 AV6

+0.00 AVI

-0.02 AV7

+0.00 AV6

-0.20 AVI

-0.07 AV8

+0.02 AV2

+0.00 AV7

-0.18 AVI

+0.00 AV5

+0.00 AV6

+0.00 AV7

-0.17 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL #

14 14 14 14 14 12 31 31 31 31 31 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 31 31 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 31 31 31 31 31 31 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 6100L 610UL 610UL 610TDL 6100L 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/14/12 11:34:43 Component: SIG A Page 73 of 73 Component: S/C A Page 73 of 73 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 2 Page 73 of 73 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 136 77 0.15 0.19 0.13 136 83 0.22 0.38 0.59 0.64 0.15 136 85 0.58 0.17 0.29 136 89 0.51 0.64 0.22 136 91 0.44 0.65 0.47 0.25 0.17 136 93 0.23 0.35 0.16 137 74 0.12 0.14 0.09 137 78 0.13 137 80 0.34 0.40 0.52 0.65 137 84 0.14 0.61 137 88 0.40 0.45 137 90 0.27 0.32 137 92 0.32 138 73 0.15 138 75 0.12 138 77 0.22 0.13 138 79 0.13 0.23 0.16 138 83 0.15 138 85 0.34 138 87 0.13 138 91 0.61 0.70 0.18 138 93 0.55 139 78 0.25 0.18 139 84 0.16 0.14 0.13 0.53 139 92 0.20 0.13 0.22 DEG 124 128 68 135 134 129 123 134 123 144 119 123 122 134 117 129 129 130 141 115 122 83 50 66 123 94 92 95 114 115 84 107 94 117 109 128 126 75 64 90 98 69 101 74 95 91 47 116 99 69 95 137 81 120 134 127 125 121 63 70 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWD 6 TWD 8 TWD 5 TWD 9 TWD 13 TWD 18 TWD 19 TWD 6 TWD 18 TWD 7 TWD 11 TWD 16 TWD 19 TWD 9 TWD 15 TWD 19 TWD 15 TWD 10 TWD 7 TWD 9 TWD 13 TWD 7 TWD 5 TWD 6 TWD 4 TWD 5 TWD II TWD 13 TWD 16 TWD 18 TWD 5 TWD 18 TWD 13 TWD 14 TWD 10 TWD 12 TWD 12 TWD 6 TWD 5 TWD 8 TWD 5 TWD 5 TWD 8 TWD 6 TWD 6 TWD 12 TWD 5 TWD 18 TWD 19 TWD 7 TWD 16 TWD 10 TWD 7 TWD 7 TWD 6 TWD 6 TWD 17 TWD 7 TWD 5 TWD 8 LOCATION AV4

+0.00 AVS

+0.00 AV7

+0.00 AV2

+0.00 AV4

+0.00 AVS

+0.00 AV6

+0.00 AV8

+0.00 AV2

+0.00 AVE

+0.00 AV7

+0.00 AV2

+0.00 AV3

+0.00 AV6

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AVE

+0.00 AV8

+0.00 AV8

+0.00 AV2

+0.00 AVS

+0.18 AV7

+0.15 AV8

+0.13 AV6

+0.00 AV7

-0.22 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV8

+0.00 AV7

+0.00 AV6

+0.00 AV4

-0.24 AVi

+0.00 AV6

+0.00 AV7

+0.00 AV7

+0.15 AV7

+0.15 AV7

+0.18 AV5

+0.00 AV7

+0.00 AV6

-0.24 AV5

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.13 AV8

+0.00 AV5

+0.00 AVI

+0.00 AV6

+0.00 AV5

+0.00 AV7

+0.18 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV3

+0.00 AV2

-0.29 EXT EXT TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL #

31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 30 30 30 30 30 30 30 30 30 31 31 31 30 30 30 30 30 30 30 30 30 30 30 30 30 30 31 31 31 31 31 31 30 30 30 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 61OUL 61OUL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 610UL 610TDL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 610UL Total Tubes

2210 Total Records: 5819

AREVA NP Inc Customer Name: St Lucie 2 Replacement Bobbin TSP Wear Indications 20% to 100%

(Degraded Tubes)

QUERY: QueryMl ROW COL VOLTS DEG CHN IND %TW LOCATION 12/14/12 11:55:01 Component:

S/G A Page 1 of 1, Enc. 3 Page 1 of 1 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 EXT EXT UTIL 1

UTIL 2

CAL # LEG PROBE Total Tubes

0 Total Records:

0

AREVA NP Inc Customer Name: St Lucie 2 Replacement Bobbin TSP Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl 12/14/12 11:51:52 Component: S/G A Page 1 of 1, Enc. 4 Page 1 of 1 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW 1

1 1

1 1

1 1

1 12 2

2 2

33 3

3 5

7 7

10 10 18 31 55 60 64 67 70

,77 85 86 88 89 90 91 92 92 92 94 95 96 103 108 109 134 11i 113 119 120 129 129 131 132 134 134 COL 2

62 80 82 96 140 154 160 162 1

7 91 972 8

158 168 168 2

92 3

9 91 66 14 157 157 156 151 18 74 21 25 22 33 24 25 27 29 31 36 29 32 39 34 36 38 38 42 87 96 114 92 91 103 105 VOLTS 0.18 0.17 0.16 0.17 0.13 0.11 0.15 0.16 0.15 0.15 0.12 0.24 0.09 0.27 0.08 0.14 0.13 0.15 0.15 0.20 0.13 0.13 0.09 0.09 0.08 0.11 0.09 0.13 0.11 0.13 0.13 0.12 0.13 0.13 0.11 0.14 0.13 0.26 0.07 0.18 0.21 0.14 0.13 0.12 0.11 0.15 0.10 0.17 0.09 0.14 0.14 0.21 0.14 0.14 0.10 0.14 0.10 0.10 0.14 0.18 0.13 0.14 0.10 0.15 DEG CHN 123 P3 145 P3 128 P3 102 P3 80 P3 123 P3 142 P3 135 P3 143 P3 137 P3 145 P3 126 P3 122 P3 103 P3 149 P3 100 P3 117 P3 140 P3 138 P3 101 P3 90 P3 92 P3 115 P3 103 P3 112 P3 142 P3 41 P3 121 P3 88 P3 147 P3 124 P3 127 P3 94 P3 130 P3 133 P3 117 P3 117 P3 120 P3 131 P3 119 P3 77 P3 103 P3 134 P3 96 P3 92 P3 124 P3 144 P3 102 P3 156 P3 136 P3 114 P3 127 P3 120 P3 74 P3 117 P3 125 P3 119 P3 95 P3 141 P3 133 P3 116 P3 125 P3 134 P3 135 P3 IND %TW TWD 18 TWD 11 TWD 11 TWO 11 TWO 9 TWO 8 TWO 11 TWD 11 TWD iI TWD 11 TWD 7 TWO 14 TWD 11 TWO 15 TWO 5 TWD 9 TWD 15 TWD 14 TWD 11 TWD 13 TWO 9 TWD 13 TWO 6 TWO 10 TWD 10 TWD 6 TWD 6 TWD 8 TWD 6 TWD 7 TWD 10 TWO 8 TWO 8 TWD 9 TWD 7 TWD 8 TWD 7 TWD 14 TWD 5 TWO 10 TWD 12 TWD 8 TWD 7 TWD 7 TWD 8 TWO 8 TWO 6 TWO 10 TWO 6 TWD 10 TWD 10 TWD 13 TWD 9 TWD 8 TWO 7 TWO 10 TWD 7 TWD 6 TWO 8 TWD 11 TWO 8 TWO 8 TWD 6 TWD 8 LOCATION 04H

-0.74 04C

+0.42 06C

-0.73 05C

-0.67 02C

+0.44 06C

-0.80 05C

-0.79 05C

-0.76 04C

-0.75 05C

-0.71 05C

-0.76 04C

-0.71 06H

-0.72 04C

-0.62 04C

-0.80 02C

+0.44 04H

-0.72 04H

-0.70 05C

-0.74 04C

+0.48 05C

-0.76 04C

+0.58 01C

+0.48 04C

-0.60 04H

+0.36 03C

-0.63 02C

+0.37 04H

-0.65 05C

-0.64 05C

+0.47 05C

+0.47 05C

+0.45 04H

+0.48 07C

+0.11 04H

-0.61 04H

+0.50 04H

-0.63 04H

+0.39 04H

-0.66 04H

-0.65 04H

-0.63 04H

+0.48 04H

+0.50 04H

+0.54 04H

+0.56 04H

-0.66 04H

-0.67 04H

+0.52 04H

-0.63 04H

-0.66 04H

-0.63 04H

+0.46 04H

-0.66 04H

+0.50 04H

-0.75 04H

-0.66 05H

-0.72 05C

-0.65 05C

+0.46 06H

-0.68 05C

+0.46 05C

+0.48 05N

+0.35 05H

+0.40 EXT EXT 07H TEH 07H TEC 07H TEC 07H TEC 07H TEC 07H TEC 07H TEC 07H TEC 07H TEC 07H TEC 07H TEC 07H TEC 07H TEH 07H TEC 07H TEC 07H TEC 07H TEH 07H TEH 07H TEC 07H TEC 07H TEC TEC TEH TEH TEC TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL 51 40 40 40 40 38 38 38 38 38 59 59 51 59 59 40 51 51 38 38 37 52 33 52 52 57 9

53 2

2 1

3 54 13 54 54 54 54 54 23 55 54 54 57 56 7

57 57 57 8

56 56 56 57 56 56 56 16 14 10 14 14 31 31

  1. LEG HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT COLD COLD COLD HOT HOT COLD COLD COLD HOT COLD NOT HOT HOT COLD COLD HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UC 610UC 610UC 610UC 610UC 610UC 610UC 610UC 610UC 610UC 610UC 610UL 610UC 610UC 610UC 610UL 610UL 610UC 610UC 610UC 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UC 610UC 610UL 610UC 610UC 610UC 610UL 610UC 610UC 610UC 610UC 610UC 610UC 610UC 610UL 610UL 610UL 610UL 610UL 610UL 610UL Total Tubes
56 Total Records:

64

AREVA NP Inc.

Customer Name: St. Lucie Unit 2 3/20/2013 6:47 AM Component: SIG A Page 1 of 1 Compbnent: S/C A Page 1 of 1 09/12 -

EOCI9 Bobbin WAR at VPAD, Enc. 5 Page 1 of 1 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1

UTIL 2

CAL # LEG PROBE Total Tubes

0 Total Records: 0

AREVA NP Inc.

Customer Name: St. Lucie Unit 2 3/20/2013 6:44 AM Component: S/G A Page 1 of 1 09/12 -

EOC19 Bobbin WAR at AV4 Locations on Row 69, Enc. 6 Page 1 of 1 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW 69 69 69 69 69 69 69 69 69 69 69 69 COL 98 100 102 106 108 110 112 118 120 122 136 138 VOLTS DEG CHN IND %TW LOCATION 0.26 101 P5 TWD 9 AV4

+1.97 0.30 90 P5 TWD 10 AV4

+0.92 0.86 85 P5 TWD 21 AV4

+1.19 0.59 77 P5 TWD 20 AV4

+1.40 0.72 92 P5 TWO 22 AV4

+0.99 0.27 80 P5 TWD 11 AV4

+1.01 0.48 83 P5 TWD 15 AV4

+1.76 0.24 74 PS TWD 7 AV4

+1.99 0.24 105 P5 TWD 7 AV4

+1.87 0.17 110 P5 TWD 5 AV4

+2.00 0.21 55 P5 TWO 7 AV4

+2.03 0.20 55 PS TWD 7 AV4

+1.77 EXT EXT UTIL 1

UTIL 2

CAL # LEG TEC TEN LAR 20 HOT TEC TEH LAR 20 HOT TEC TEH LAR 20 HOT TEC TEH LAR 30 HOT TEC TEH LAR 29 HOT TEC TEH LAR 29 HOT TEC TEH LAR 27 HOT TEC TEH LAR 25 HOT TEC TEH LAR 25 HOT TEC TEH LAR 25 HOT TEC TEH LAR 19 HOT TEC TEH LAR 19 HOT PROBE 610UL 61OUL 61OUL 61OUL 610UL 610OUL 61 OUL 610UL 61 OUL 610UL 61 0UL 610LUL Total Tubes

12 Total Records:

12

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 15:04:29 Component: S/G B Page 1 of 4 Component: S/C B Page 1 of 4 Bobbin AVB Wear Indications 20% to 100%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 7 Page 1 of 4 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 54 9

0.78 63 158 0.76 68 13 0.66 78 99 0.86 87 84 0.57 0.62 89 84 0.72 90 85 0.85 0.76 91 76 0.79 92 83 1.13 92 85 0.79 92 95 0.73 93 84 0.66 93 86 0.72 94 81 0.52 94 83 0.68 0.86 0.62 94 85 0.85 0.91 94 95 0.94 0.74 0.69 95 84 0.97 1.03 0.89 0.54 95 86 1.02 0.90 96 83 0.74 96 85 0.88 1.23 0.97 2.67 3.15 96 87 0.83 97 76 0.68 97 84 0.82 0.69 97 86 1.12 0.71 0.87 0.80 98 83 0.55 98 85 1.27 1.65 1.17 0.83 98 87 0.97 1.35 98 91 0.69 99 82 0.97 99 84 0.71 0.79 0.94 99 86 0.87 0.94 0.79 1.42 100 83 1.33 0.97 0.87 100 85 0.66 100 87 1.01 101 82 0.84 0.91 1.52 2.00 0.55 101 86 1.11 0.82 101 98 0.72 102 81 0.57 0.53 0.56 102 83 0.65 0.80 102 85 1.02 DEG CHN 113 P2 110 P2 121 P2 122 P2 114 P2 115 P2 121 P2 111 P2 121 P2 118 P2 113 P2 112 P2 113 P2 122 P2 111 P2 11 P2 115 P2 118 P2 112 P2 99 P2 107 P2 118 P2 115 P2 116 P2 112 P2 109 P2 115 P2 113 P2 111 P2 112 P2 126 P2 109 P2 115 P2 115 P2 104 P2 104 P2 109 P2 117 P2 120 P2 126 P2 115 P2 122 P2 115 P2 114 P2 112 P2 107 P2 103 P2 106 P2 97 P2 105 P2 108 P2 102 P2 113 P2 106 P2 120 P2 118 P2 111 P2 106 P2 106 P2 106 P2 117 P2 121 P2 114 P2 118 P2 115 P2 111 P2 112 P2 116 P2 112 P2 111 P2 111 P2 111 P2 121 P2 94 P2 117 P2 105 P2 115 P2 109 P2 105 P2 IND %TW TWD 23 TWD 21 TWD 20 TWD 22 TWD 20 TWD 21 TWD 20 TWD 22 TWD 20 TWD 22 TWD 27 TWD 23 TWD 21 TWD 20 TWD 20 TWD 20 TWD 23 TWD 26 TWD 22 TWD 23 TWD 24 TWD 24 TWD 21 TWD 20 TWD 28 TWD 28 TWD 26 TWD 20 TWD 25 TWD 23 TWD 21 TWD 24 TWD 28 TWD 25 TWD 38 TWD 38 TWD 22 TWD 23 TWD 23 TWD 20 TWD 26 TWD 20 TWD 22 TWD 21 TWD 20 TWD 29 TWD 32 TWD 28 TWD 23 TWD 24 TWD 28 TWD 20 TWD 25 TWD 23 TWD 25 TWD 27 TWD 23 TWD 24 TWD 21 TWD 29 TWD 29 TWD 25 TWD 23 TWD 20 TWD 24 TWD 26 TWD 27 TWD 33 TWD 36 TWD 20 TWD 26 TWD 21 TWD 20 TWD 21 TWD 20 TWD 20 TWD 22 TWD 25 TWD 26 LOCATION AV7

+0.25 AV2

-0.23 AV6

+0.00 AV5

+0.00 AV5

+0.00 AV4

+0.00 AV5

+0.05 AV7

+0.00 AV6

-0.07 AV5

+0.00 AV5

+0.00 AV6

+0.00 AV4

+0.00 AV4

+0.00 AV4

+0.00 AV4

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV2

+0.00 AV4

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV7

+0.00 AV5

+0.00 AV4

+0.00 AV4

+0.00 AV2

+0.00 AV4

+0.16 AV6

+0.12 AV7

+0.00 AV3

+0.02 AV6

+0.00 AV5

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV5

+0.00 AV2

+0.09 AV3

+0.05 AV4

+0.12 AV7

+0.05 AV7

+0.00 AV6

+0.00 AV4

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV7

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV7

+0.00 AV5

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV3

+0.00 AV4

+0.00 AV6

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.09 EXT EXT TEH TEC TEC TEH TEH TEC TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEH TEC TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC UTIL 1

UTIL 2

CAL 61 4

62 25 16 16 15 15 15 6

6 4

13 6

16 7

7 7

7 5

5 13 13 13 7

7 7

7 15 15 6

4 4

4 4

DWS 42 16 7

6 6

16 16 16 16 7

5 5

5 5

15 15 15 6

7 7

7 15 15 15 15 6

6 6

4 16 7

7 7

7 7

16 16 14 7

7 7

7 7

5

  1. LEG COLD HOT COLD HOT COLD COLD COLD COLD COLD COLD COLD COLD HOT COLD HOT COLD COLD COLD COLD COLD COLD HOT HOT HOT COLD COLD COLD COLD HOT HOT COLD COLD COLD COLD COLD HOT HOT COLD COLD COLD HOT HOT HOT HOT COLD COLD COLD COLD COLD HOT HOT HOT COLD COLD COLD COLD HOT HOT HOT HOT COLD COLD COLD COLD HOT COLD COLD COLD COLD COLD HOT HOT HOT COLD COLD COLD COLD COLD COLD PROBE 61OUL 610UL 61OUL 610UL 61OUL 61OUL 610UL 610UL 610UL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 6100L 610UL 610UL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 6100L 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610DL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 61OUL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 15:04:29 Component: S/G B Page 2 of 4 Bobbin AVB Wear Indications 20% to 100%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 7 Page 2 of 4 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 1.41 102 87 1.00 1.11 103 84 1.24 0.77

0. 67 103 86 0.99 1.08 104 83 0.80 104 85 2.32 0.79 0.92 104 87 0.87 105 72 0.69 105 84 1.03 2.44 105 86 0.76 1.08 1.26 105 96 0.79 106 83 0.64 0.83 106 85 0.61 0.99 106 87 0.74 106 97 0.90 107 84 1.09 1.36 1.26 107 98 0.71 107 102 1.61 1.25 108 83 0.74 108 85 2.29 108 95 0.72 109 84 1.35 1.70
0. 92 109 86 0.74 1.17 0.98 1.71 109 98 0.84 1.10 110 83 0.93 0.86 110 85 0.76 0.71 1.45 1.41 110 87 0.81 110 95 0.97 111 84 0.96 1.06 0.96 111 86 0.80 1.76 1.06 111 94 0.99 112 83 0.87
1. 97 1.34 112 85 2.60 1.34 0.63 113 68 0.64 113 84 1.08 1.85 2.16 0.86 113 86 1.17 3.03 113 88 0.86 114 83 1.89 1.01 114 87 0.98 0.73 115 84 1.14 1.40 115 86 1.07 DEG CHN 107 P2 103 P2 108 P2 110 P2 118 P2 122 P2 110 P2 111 P2 117 P2 105 P2 121 P2 118 P2 113 P2 118 P2 111 P2 104 P2 115 P2 114 P2 114 P2 126 P2 110 P2 120 P2 113 P2 116 P2 126 P2 124 P2 114 P2 118 P2 110 P2 117 P2 114 P2 115 P2 117 P2 107 P2 120 P2 111 P2 106 P2 107 P2 107 P2 110 P2 111 P2 109 P2 123 P2 118 P2 112 P2 113 P2 115 P2 120 P2 114 P2 118 P2 109 P2 112 P2 109 P2 111 P2 116 P2 118 P2 110 P2 116 P2 111 P2 117 P2 115 P2 117 P2 106 P2 117 P2 120 P2 114 P2 112 P2 110 P2 107 P2 116 P2 102 P2 104 P2 115 P2 109 P2 108 P2 113 P2 113 P2 115 P2 115 P2 108 P2 IND %TW TWD 30 TWD 24 TWD 26 TWD 28 TWD 22 TWD 20 TWD 24 TWD 25 TWD 22 TWD 36 TWD 23 TWD 25 TWD 22 TWD 24 TWD 28 TWD 39 TWD 21 TWD 25 TWD 27 TWD 21 TWD 22 TWD 25 TWD 20 TWD 26 TWD 21 TWD 23 TWD 26 TWD 29 TWD 28 TWD 20 TWD 31 TWD 28 TWD 21 TWD 36 TWD 20 TWD 32 TWD 35 TWD 27 TWD 20 TWD 27 TWD 24 TWD 32 TWD 22 TWD 25 TWD 27 TWD 26 TWD 22 TWD 21 TWD 31 TWD 30 TWD 21 TWD 24 TWD 25 TWD 26 TWD 25 TWD 21 TWD 32 TWD 25 TWD 25 TWD 23 TWD 34 TWD 29 TWD 38 TWD 30 TWD 20 TWD 23 TWD 29 TWD 36 TWD 37 TWD 26 TWD 27 TWD 38 TWD 22 TWD 36 TWD 28 TWD 24 TWD 20 TWD 27 TWD 30 TWD 25 LOCATION EXT EXT AV7

+0.07 TEN TEC AV6

+0.00 TEC TEN AVS

+0.00 TEC TEH AV3

+0.00 TEN TEC AV5

+0.00 TEH TEC AV7

+0.00 TEH TEC AV5

+0.00 TEC TEN AV4

+0.00 TEC TEH AV4

+0.00 TEN TEC AV3

+0.05 TEH TEC AV4

-0.07 TEH TEC AV5

+0.02 TEH TEC AV5

+0.00 TEC TEH AV4

+0.09 TEH TEC AV5

+0.00 TEH TEC AV6

+0.00 TEH TEC AV7

+0.00 TEC TEH AV5

+0.00 TEC TEH AV4

+0.00 TEC TEH AV5

+0.05 TEC TEH AV3

+0.00 TEH TEC AV4

+0.00 TEH TEC AV2

+0.00 TEH TEC AV7

-0.07 TEH TEC AV3

+0.00 TEC TEH AV3

+0.00 TEC TEH AV4

+0.00 TEH TEC AV5

+0.00 TEH TEC AV6

+0.00 TEH TEC AV5

+0.00 TEC TEH AV4

+0.00 TEC TEH AV5

+0.00 TEC TEH AV5

+0.00 TEH TEC AV2

+0.07 TEH TEC AV3

-0.32 TEC TEH AV4

+0.00 TEH TEC AV5

+0.00 TEH TEC AV7

+0.00 TEH TEC AV7

+0.00 TEC TEH AV6

+0.00 TEC TEH AV5

+0.00 TEC TEH AV4

+0.00 TEC TEH AV4

+0.00 TEC TEH AV3

+0.00 TEC TEH AV4

+0.00 TEH TEC AV5

+0.00 TEH TEC AV3

+0.09 TEH TEC AV4

-0.02 TEH TEC AV5

-0.02 TEH TEC AV7

+0.00 TEH TEC AV6

+0.00 TEC TEH AV4

+0.00 TEC TEH AV3

+0.00 TEH TEC AV4

+0.00 TEH TEC AV5

+0.00 TEH TEC AV7

+0.00 TEC TEH AV6

+0.00 TEC TEH AV4

+0.00 TEC TEH AV5

+0.00 TEC TEH AV3

+0.00 TEH TEC AV4

+0.00 TEH TEC AV5

+0.00 TEH TEC AV2

+0.00 TEH TEC AV5

+0.00 TEH TEC AV7

+0.00 TEH TEC AV4

+0.09 TEH TEC AV4

+0.00 TEH TEC AV5

+0.00 TEH TEC AV6

+0.00 TEH TEC AV7

+0.00 TEH TEC AV7

+0.00 TEC TEH AV6

+0.00 TEC TEH AV5

+0.00 TEC TEH AV5

+0.00 TEH TEC AV6

+0.00 TEH TEC AV5

+0.00 TEC TEH AV3

+0.00 TEC TEH AV4

+0.00 TEH TEC AV7

+0.00 TEH TEC AV7

+0.00 TEC TEH UTIL 1

UTIL 2

CAL #

5 15 15 6

6 6

15 15 6

4 4

4 16 9

7 7

16 16 16 14 7

7 4

4 41 13 6

6 6

13 13 13 6

4 14 7

7 7

15 15 15 15 14 14 7

7 4

4 4

4 16 13 6

6 6

16 16 16 13 6

6 6

4 4

4 9

7 7

7 7

15 15 16 7

7 16 16 6

6 16 LEG COLD HOT HOT COLD COLD COLD HOT HOT COLD COLD COLD COLD HOT COLD COLD COLD HOT HOT HOT HOT COLD COLD COLD COLD HOT HOT COLD COLD COLD HOT HOT HOT COLD COLD HOT COLD COLD COLD HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD HOT HOT COLD COLD COLD HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT COLD COLD HOT HOT COLD COLD HOT PROBE 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 61OUL 61OUL 610UL 61OUL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 15:04:29 Component: S/G B Page 3 of 4 Bobbin AVB Wear Indications 20% to 100%

(Imperfect Tubes), Enc. 7 Page 3 of 4 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 QUERY: QueryMl ROW COL VOLTS 1.56 1.17 1.55 115 94 0.76 115 98 1.09 116 83 0.86 116 85 3.31 0.98 116 87 1.18

0. 94 117 84 0.68 0.70 117 86 1.80 117 90 0.71 118 83 1.84
0. 62 118 85 0.86 1.04 1.36 1.67 2.97 118 87 1.16 1.02 119 82 1.02 119 84 0.68 120 85 0.87 0.86 1.09 1.27 121 84 0.90 121 86 1.36 2.90 2.43 1.82 121 90 0.92 122 83 0.53 0.92 122 85 1.03 1.00 1.25 0.68 3.08 122 87 1.07 1.53 1.28 123 84 0.68 0.67 0.74 123 86 0.78 123 90 0.87 1.38 124 85 1.08 1.00 2.46 0.91 2.06 124 87 0.95 0.81 125 84 0.61 125 86 1.62 0.97 1.11 0.80 127 86 2.20 128 85 0.85 1.34 129 68 0.54 129 84 0.60 129 86 0.80 0.87 129 102 0.87 130 85 2.12 2.63 0.74 0.67 131 86 1.28 1.03 0.94 132 67 0.54 0.96 DEG CHN 106 P2 111 P2 111 P2 122 P2 110 P2 113 P2 106 P2 115 P2 107 P2 105 P2 104 P2 115 P2 103 P2 116 P2 106 P2 116 P2 111 P2 111 P2 113 P2 116 P2 105 P2 116 P2 113 P2 119 P2 114 P2 110 P2 113 P2 116 P2 115 P2 107 P2 111 P2 104 P2 104 P2 105 P2 116 P2 100 P2 114 P2 115 P2 121 P2 113 P2 116 P2 106 P2 112 P2 115 P2 112 P2 117 P2 123 P2 120 P2 116 P2 106 P2 106 P2 113 P2 115 P2 108 P2 118 P2 116 P2 114 P2 113 P2 108 P2 110 P2 106 P2 108 P2 106 P2 108 P2 118 P2 110 P2 115 P2 112 P2 105 P2 106 P2 121 P2 108 P2 107 P2 122 P2 125 P2 115 P2 114 P2 112 P2 103 P2 115 P2 IND %TW TWD 30 TWD 26 TWD 30 TWD 21 TWD 26 TWD 23 TWD 39 TWD 25 TWD 27 TWD 24 TWD 23 TWD 23 TWD 32 TWD 20 TWD 35 TWD 22 TWD 24 TWD 26 TWD 30 TWD 32 TWD 37 TWD 26 TWD 24 TWD 26 TWD 20 TWD 24 TWD 24 TWD 27 TWD 29 TWD 27 TWD 29 TWD 38 TWD 36 TWD 32 TWD 23 TWD 20 TWD 27 TWD 26 TWD 26 TWD 29 TWD 21 TWD 37 TWD 25 TWD 30 TWD 28 TWD 20 TWD 20 TWD 21 TWD 21 TWD 23 TWD 29 TWD 27 TWD 26 TWD 37 TWD 25 TWD 35 TWD 24 TWD 22 TWD 21 TWD 31 TWD 24 TWD 26 TWD 21 TWD 35 TWD 24 TWD 30 TWD 20 TWD 21 TWD 21 TWD 23 TWD 22 TWD 35 TWD 38 TWD 22 TWD 21 TWD 28 TWD 25 TWD 23 TWD 20 TWD 28 LOCATION AV6

+0.00 AV5

+0.00 AV4

+0.00 AV5

+0.00 AV5

+0.00 AV4

+0.00 AV2

+0.00 AVS

+0.07 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV6

+0.00 AV5

+0.00 AV5

+0.00 AV5

+0.00 AV6

+0.00 AV2

+0.12 AV3

+0.14 AV4

-0.05 AV7

+0.02 AV5

-0.04 AV5

+0.00 AV4

+0.00 AV5

+0.00 AV2

+0.00 AV3

+0.09 AV4

-0.07 AV5

+0.02 AV7

+0.00 AV6

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV4

+0.00 AV3

+0.00 AV4

+0.00 AV6

-0.07 AV7

+0.00 AV3

+0.12 AV4

+0.00 AV5

-0.04 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV4

+0.00 AV6

+0.00 AV7

+0.00 AV5

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.09 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.02 AV5

+0.00 AV4

+0.00 AV4

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV5

+0.00 AV3

+0.00 AV5

+0.07 AV3

+0.07 AV5

+0.00 AV6

+0.00 AV4

+0.00 AV4

+0.00 AV3

+0.02 AV5

,+0.00 AV6

+0.00 AV7

+0.05 AV7

+0.00 AV6

+0.00 AV4

+0.00 AV4

+0.00 AV8

+0.09 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEC TEH TEH TEC TEC TEH TEC TEH TEH TEC TEH TEC TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC UTIL 1

UTIL 2

CAL #

16 16 16 13 13 6

DWS 42 4

15 15 7

7 15 16 7

7 4

4 4

4 DWS 42 16 16 6

6 4

4 4

4 7

15 15 15 15 16 7

7 4

4 4

4 DWS 42 16 16 16 6

6 6

16 15 15 4

4 4

4 4

15 15 7

15 15 15 15 16 4

4 9

7 15 15 14 4

4 4

4 16 16 16 9

9 LEG HOT HOT HOT HOT HOT COLD HOT COLD HOT HOT COLD COLD HOT HOT COLD COLD COLD COLD COLD COLD HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT COLD COLD COLD HOT HOT HOT COLD COLD COLD COLD COLD HOT HOT COLD HOT HOT HOT HOT HOT COLD COLD COLD COLD HOT HOT HOT COLD COLD COLD COLD HOT HOT HOT COLD COLD PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UDL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 15:04:29 Component: S/G B Page 4 of 4 Bobbin AVB Wear Indications 20% to 100%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 7 Page 4 of 4 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL 133 68 133 90 134 91 134 103 135 82 135 84 135 90 136 91 138 85 VOLTS 1.59 1.17 0.68 0.68 0.71 0.89 1.47 0.77 1.05 0.75 0.82 1.09 DEG CHN 112 P2 116 P2 127 P2 119 P2 113 P2 118 P2 106 P2 110 P2 118 P2 11 P2 114 P2 113 P2 IND %TW TWD 34 TWD 26 TWD 20 TWD 20 TWD 20 TWD 23 TWD 30 TWD 21 TWD 25 TWD 21 TWD 22 TWD 27 LOCATION AV5

-0.02 AV8

+0.00 AV8

+0.00 AV8

+0.00 AV3

+0.00 AV4

+0.00 AV6

+0.00 AV4

+0.00 AV7

+0.00 AV5

+0.00 AV6

+0.00 AV4

+0.00 EXT EXT UTIL 1

UTIL 2

TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH CAL 9

16 31 32 31 31 31 31 31 31 32 32

  1. LEG COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 61OUL 61OUL 610UL 610UL 61OUL 61OUL 610UL 61OUL 61OUL 61OUL 61OUL 610UL Total Tubes
126 Total Records: 251

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:33 Component: S/G B Page 1 of 48 Component: S/C B Page 1 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 1 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 32 165 0.08 34 165 0.15 0.13 35 162 0.09 36 163 0.14 36 165 0.14 37 6

0.19 37 164 0.12 38 163 0.16 0.12 38 165 0.09 39 6

0.15 0.10 39 162 0.09 39 164 0.27 0.15 0.09 40 163 0.14 0.18 41 6

0.11 41 164 0.16 42 7

0.11 42 9

0.11 43 6

0.19 43 164 0.12 44 7

0.15 0.24 44 9

0.16 44 11 0.10 0.12 44 163 0.27 0.28 0.26 0.17 45 8

0.16 45 12 0.16 45 160 0.12 45 162 0.13 0.14 0.19 0.11 0.12 0.17 46 7

0.32 0.23 46 9

0.10 0.15 46 11 0.12 46 17 0.12 46 161 0.19 0.16 46 163 0.16 0.15 0.09 47 8

0.19 0.14 47 10 0.25 0.10 47 12 0.13 0.11 47 14 0.11 47 24 0.13 47 158 0.09 47 160 0.13 0.12 0.07 47 162 0.15 0.16 0.17 48 7

0.14 0.36 48 9

0.15 0.12 0.12 0.23 48 11 0.14 48 161 0.17 0.11 48 163 0.35 DEG CHN 45 P2 116 P2 118 P2 72 P2 106 P2 92 P2 128 P2 59 P2 121 P2 103 P2 142 P2 88 P2 44 P2 124 P2 121 P2 133 P2 50 P2 111 P2 104 P2 102 P2 96 P2 131 P2 124 P2 131 P2 127 P2 11 P2 122 P2 108 P2 68 P2 127 P2 114 P2 124 P2 131 P2 78 P2 120 P2 128 P2 103 P2 88 P2 92 P2 91 P2 127 P2 86 P2 62 P2 125 P2 112 P2 108 P2 128 P2 129 P2 135 P2 127 P2 136 P2 88 P2 97 P2 115 P2 120 P2 129 P2 114 P2 105 P2 100 P2 88 P2 128 P2 98 P2 98 P2 100 P2 134 P2 110 P2 92 P2 130 P2 115 P2 73 P2 117 P2 92 P2 134 P2 117 P2 112 P2 132 P2 106 P2 106 P2 111 P2 IND %TW TWD 3 TWD 7 TWD 6 TWD 4 TWD 6 TWD 6 TWD 8 TWD 5 TWD 7 TWD 6 TWD 4 TWD 7 TWD 4 TWD 4 TWD 11 TWD 7 TWD 4 TWD 6 TWD 7 TWD 5 TWD 7 TWD 5 TWD 5 TWD 8 TWD 5 TWD 6 TWD 9 TWD 7 TWD 5 TWD 6 TWD 10 TWD 10 TWD 10 TWD 7 TWD 7 TWD 7 TWD 5 TWD 5 TWD 6 TWD 8 TWD 4 TWD 5 TWD 7 TWD 13 TWD 10 TWD 5 TWD 7 TWD 5 TWD 6 TWD 8 TWD 7 TWD 7 TWD 7 TWD 4 TWD 8 TWD 7 TWD 10 TWD 5 TWD 6 TWD 5 TWD 5 TWD 8 TWD 4 TWD 6 TWD 6 TWD 3 TWD 7 TWD 7 TWD 8 TWD 6 TWD 13 TWD 6 TWD 5 TWD 5 TWD 9 TWD 7 TWD 7 TWD 4 TWD 13 LOCATION AV7

+0.23 AV2

-0.28 AV7

+0.16 AV2

-0.21 AV7

+0.21 AV2

-0.33 AV7

+0.00 AV2

-0.28 AV2

-0.28 AV7

+0.19 AV7

+0.19 AV2

-0.16 AV7

-0.16 AV2

-0.26 AV2

-0.26 AV7

+0.16 AV8

+0.22 AV2

-0.30 AV7

+0.23 AV2

+0.00 AV7

-0.30 AV7

+0.21 AV2

-0.16 AV3

-0.27 AV6

+0.19 AV7

+0.00 AV3

+0.00 AV2

+0.00 AVI

-0.14 AV8

+0.23 AV2

-0.26 AV3

-0.33 AV6

+0.26 AV8

+0.21 AV6

+0.00 AV3

+0.00 AV3

-0.25 AVI

+0.16 AV2

-0.25 AV3

-0.28 AV6

+0.21 AV7

-0.30 AV8

-0.23 AV3

-0.16 AV7

+0.30 AV3

-0.18 AV6

+0.23 AV3

+0.00 AV3

-0.14 AV2

-0.26 AV6

+0.19 AV2

-0.30 AV6

+0.21 AV8

+0.17 AV2

-0.11 AV6

+0.23 AV3

+0.28 AV7

+0.23 AV3

-0.16 AV7

+0.23 AV3

+0.30 AV3

+0.00 AV6

+0.14 AV2

-0.26 AV3

-0.26 AV7

+0.14 AV2

-0.26 AV3

-0.30 AV6

+0.16 AV7

+0.00 AV3

+0.00 AV7

+0.00 AV6

+0.00 AV3

+0.00 AV2

+0.00 AV3

-0.21 AV6

+0.18 AV7

+0.16 AV2

-0.26 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEC TEH TEH TEC TEH TEC TEH TEC TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL 4

3 3

3 4

4 64 4

3 3

3 63 63 3

3 3

3 4

4 64 4

63 61 63 3

62 62 62 61 61 4

4 4

4 62 62 4

4 4

4 4

4 4

61 61 61 61 62 61 3

3 3

3 3

61 61 61 61 61 61 61 32 4

3 3

3 3

3 3

62 62 62 62 62 62 61 4

4 4

  1. LEG HOT HOT HOT HOT HOT HOT COLD HOT HOT HOT HOT COLD COLD HOT HOT HOT HOT HOT HOT COLD HOT COLD COLD COLD HOT COLD COLD COLD COLD COLD HOT HOT HOT HOT COLD COLD HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD HOT HOT 4OT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 61OUL 61OUL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UDL 610UL 610UL 610UL 610UL 610UL 610TDL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:33 Component: S/G B Page 2 of 48 Component: S/G B Page 2 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 2 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 49 8

0.17 0.19 0.13 49 10 0.25 49 12 0.23 0.09 49 14 0.13 49 24 0.18 49 158 0.13 0.15 49 160 0.18 0.16 49 162 0.12 0.11 50 7

0.19 0.21 0.21 50 9

0.14 0.23 50 11 0.14 0.14 50 13 0.13 50 159 0.13 50 161 0.13 0.23 50 163 0.11 51 8

0.19 0.24 0.18 0.12 51 10 0.15 0.10 51 12 0.10 51 14 0.18 0.13 51 24 0.23 51 154 0.08 51 158 0.14 51 160 0.08 0.12 51 162 0.18 0.22 52 9

0.12 0.22 0.18 52 11 0.20 0.16 0.16 0.10 52 13 0.11 0.14 0.18 52 17 0.12 52 19 0.13 52 23 0.23 52 39 0.10 52 151 0.10 52 161 0.34 53 8

0.12 0.10 0.19 0.17 0.11 53 10 0.12 0.19 53 14 0.14 53 16 0.12 53 24 0.29 53 158 0.11 0.22 0.13 0.21 53 160 0.24 0.11 0.15 53 162 0.39 0.13 54 9

0.14 0.26 0.31 DEG 110 132 135 113 114 63 114 94 55 103 93 ill 96 118 109 129 116 108 117 98 117 105 77 105 126 116 108 125 138 115 126 65 119 125 110 117 81 94 144 138 101 107 71 109 102 116 113 131 77 117 121 122 118 123 130 122 129 113 108 ill 117 116 136 136 113 110 117 97 72 ill 94 104 114 118 121 126 128 115 105 118 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWO TWD TWD TWD TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW LOCATION 7

AV7

+0.00 8

AV6

+0.00 6

AV2

+0.00 10 AV3

+0.00 9

AV3

+0.00 4

AV2

+0.00 6

AV3

+0.00 7

AV3

+0.32 5

AV6

+0.16 6

AV7

+0.18 7

AV2

-0.21 7

AV7

+0.14 5

AV2

-0.25 5

AV3

-0.25 8

AV2

+0.28 9

AV3

-0.14 9

AV7

+0.28 6

AV2

-0.14 10 AV7

+0.25 6

AV7

+0.00 6

AV3

+0.00 6

AV3

+0.09 5

AV6

-0.28 6

AV2

-0.26 10 AV6

+0.14 5

AV3

+0.23 8

AV2

-0.16 10 AV3

-0.14 8

AV6

+0.23 5

AV7

+0.30 7

AV3

-0.14 4

AV8

-0.18 5

AV3

-0.18 8

AV2

-0.16 6

AV3

-0.18 12 AV3

+0.00 4

AV6

+0.00 6

AV3

-0.18 4

AV7

+0.11 5

AV2

-0.21 8

AV2

-0.28 9

AV3

-0.26 5

AV8

+0.00 9

AV7

+0.00 7

AV2

+0.00 9

AV3

-0.14 7

AV6

+0.23 7

AV7

+0.25 5

AVI

-0.14 5

AV7

+0.00 6

AV3

+0.00 7

AV2

+0.00 5

AV3

+0.00 6

AV3

+0.00 12 AV3

+0.00 5

AV3

-0.16 4

AV6

+0.00 12 AV6

+0.19 6

AVl

-0.14 4

AV2

-0.14 8

AV3

-0.16 7

AV7

+0.28 5

AV8

+0.21 5

AV3

+0.00 8

AV2

+0.00 6

AV3

+0.00 5

AV3

+0.00 10 AV3

+0.34 5

AV2

-0.25 8

AV3

-0.23 5

AV6

+0.18 8

AV7

+0.23 9

AV2

-0.21 5

AV3

-0.23 6

AV7

+0.19 15 AV3

-0.26 6

AV6

+0.14 6

AVI

-0.14 11 AV2

-0.14 12 AV3

-0.16 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC UTIL 1

UTIL 2

CAL 62 62 62 62 62 62 62 31 4

4 4

4 4

4 61 61 61 61 61 62 62 61 4

3 3

3 61 61 61 61 61 61 61 61 61 32 6

4 3

3 3

3 62 62 62 61 61 61 61 62 62 62 62 59 32 28 6

4 61 61 61 61 61 62 62 62 62 31 4

4 4

4 4

4 4

3 3

61 61 61

  1. LEG COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD PROBE 610UL 610UL 610UL 610TDL 610UL 610UL 610UL 610UL 610UDL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TDL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 6100L 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:33 Component: S/G B Page 3 of 48 Component: S/C B Page 3 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 3 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.21 0.11 0.15 54 11 0.11 0.13 0.12 54 13 0.13 0.12 0.15 54 15 0.14 54 29 0.13 54 153 0.11 54 155 0.14 54 157 0.09 54 159 0.11 0.13 0.15 54 161 0.14 0.12 0.22 0.48 0.06 55 10 0.16 0.13 55 12 0.15 0.12 0.22 0.15 0.11 0.10 55 14 0.32 55 16 0.16 55 24 0.15 55 146 0.14 55 154 0.08 55 156 0.13 0.08 55 158 0.13 0.11 0.13 55 160 0.26 0.09 0.38 56 9

0.11 0.42 0.52 0.11 56 11 0.11 0.13 0.11 0.12 0.11 56 13 0.15 0.10 56 15 0.15 56 51 0.15 56 139 0.12 56 155 0.14 56 157 0.16 56 159 0.08 0.13 0.11 56 161 0.25 0.50 57 10 0.23 0.28 0.14 0.16 57 12 0.13 0.14 0.11 57 14 0.14 57 24 0.37 57 130 0.15 57 152 0.14 57 154 0.13 0.15 0.12 57 156 0.14 0.15 DEG CHN 95 P2 58 P2 112 P2 63 P2 115 P2 118 P2 59 P2 90 P2 100 P2 141 P2 113 P2 78 P2 125 P2 0

P2 103 P2 111 P2 115 P2 115 P2 85 P2 119 P2 115 P2 30 P2 119 P2 102 P2 139 P2 143 P2 121 P2 110 P2 136 P2 135 P2 125 P2 131 P2 108 P2 112 P2 109 P2 73 P2 87 P2 86 P2 97 P2 56 P2 108 P2 113 P2 117 P2 59 P2 104 P2 114 P2 70 P2 112 P2 98 P2 85 P2 90 P2 95 P2 117 P2 117 P2 132 P2 107 P2 141 P2 132 P2 108 P2 83 P2 77 P2 80 P2 91 P2 113 P2 105 P2 108 P2 114 P2 77 P2 129 P2 92 P2 68 P2 125 P2 105 P2 114 P2 96 P2 107 P2 116 P2 92 P2 125 P2 95 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWO TWD TWD TWD TWD TWD TWD TWD

%TW 9

5 7

5 6

5 6

6 7

6 5

5 6

4 5

5 6

6 5

9 17 3

7 6

7 5

9 7

5 5

13 7

9 6

3 5

4 5

5 5

11 4

14 5

15 17 5

5 6

5 5

5 6

4 6

7 5

6 7

4 6

5 10 16 9

11 6

7 6

6 5

6 12 6

6 5

6 5

6 6

LOCATION AV6

+0.23 AV6

-0.25 AV8

+0.25 AV8

+0.00 AV7

+0.00 AV2

+0.00 AVI

-0.09 AV3

+0.02 AV7

+0.25 AV7

+0.21 AV3

+0.00 AV6

+0.00 AV6

-0.34 AV7

+0.00 AV2

+0.00 AV6

+0.14 AV7

+0.14 AVl

-0.23 AV2

-0.23 AV3

-0.25 AV6

+0.14 AV8

+0.19 AVl

-0.16 AV7

+0.23 AVI

-0.12 AV2

-0.09 AV3

-0.11 AV7

+0.05 AV8

-0.14 AV6

+0.23 AV3

-0.16 AV3

+0.23 AV3

+0.00 AV6

+0.11 AV7

+0.00 AV7

+0.18 AV6

+0.09 AV3

-0.21 AV6

+0.16 AV7

+0.21 AV2

-0.26 AV3

-0.23 AV7

+0.19 AV8

+0.00 AV7

+0.00 AV3

  • +0.00 AV2

+0.00 AV2

-0.14 AV3

-0.14 AV6

+0.25 AV7

+0.23 AV8

+0.25 AV7

+0.00 AV2

+0.00 AV7

+0.00 AV3

-0.18 AV6

+0.00 AV6

+0.00 AV7

+0.16 AV7

-0.39 AV8

+0.19 AV6

+0.00 AV3

-0.23 AV6

+0.14 AV8

+0.00 AV7

+0.00 AV2

+0.00 AVI

+0.00 AV7

+0.00 AV3

+0.00 AVI

+0.00 AV3

+0.00 AV3

+0.30 AV6

-0.30 AV6

+0.00 AV7

+0.16 AV6

+0.09 AV3

-0.05 AV6

+0.00 AV2

+0.00 EXT TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC EXT UTIL 1

UTIL 2

TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH CAL 61 61 61 62 62 62 61 61 61 61 29 6

5 6

4 4

4 3

3 3

3 3

61 61 61 61 61 61 61 61 61 61 32 5

6 5

5 4

4 4

3 3

3 62 62 62 62 61 61 61 61 61 62 62 62 24 17 6

5 3

3 3

4 4

62 62 62 62 62 62 62 62 31 20 6

5 5

5 6

6

  1. LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:33 Component: S/G B Page 4 of 48 Component: 5/0 B Page 4 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 4 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 57 158 0.19 0.27 0.20 0.28 57 160 0.31 0.20 0.17 58 9

0.14 0.25 0.34 0.11 58 11 0.19 0.20 58 13 0.21 58 15 0.11 58 17 0.10 58 23 0.14 58 51 0.11 58 143 0.14 58 155 0.14 58 157 0.11 0.21 0.12 58 159 0.13 0.12 0.12 0.21 0.13 0.11 58 161 0.11 0.25 59 10 0.20 0.18 0.14 0.35 0.21 59 12 0.11 0.15 0.12 0.30 59 14 0.10 0.38 0.11 59 16 0.12 59 152 0.11 59 154 0.12 0.10 59 156 0.11 0.13 0.14 59 158 0.18 0.23 0.26 0.14 0.31 59 160 0.18 0.19 0.19 60 11 0.13 0.35 0.22 0.13 0.10 60 13 0.24 0.17 0.11 0.10 0.14 60 15 0.21 60 17 0.13 60 23 0.18 60 51 0.08 60 149 0.21 60 153 0.24 60 157 0.12 0.14 0.11 0.21 0.14 60 159 0.10 DEG 87 112 96 101 113 123 84 139 125 108 88 104 131 86 130 128 119 147 ill 132 54 110 73 52 90 84 107 121 103 118 131 99 106 134 113 126 136 132 128 124 71 122 128 125 110 127 131 66 80 98 106 116 91 95 100 95 121 104 56 116 134 110 117 94 125 85 58 96 98 114 127 128 131 105 65 99 107 107 83 84 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWD 7 TWD 10 TWD 8 TWD 10 TWD 11 TWD 8 TWD 7 TWD 7 TWD 11 TWD 13 TWD 5 TWD 8 TWD 8 TWD 9 TWD 5 TWD 5 TWD 6 TWD 4 TWD 6 TWD 6 TWD 5 TWD 8 TWD 5 TWD 5 TWD 5 TWD 5 TWD 8 TWD 5 TWD 5 TWD 5 TWD 10 TWD 9 TWD 8 TWD 6 TWD 13 TWD 9 TWD 5 TWD 7 TWD 5 TWD 12 TWD 5 TWD 14 TWD 5 TWD 6 TWD 5 TWD 5 TWD 4 TWD 5 TWD 5 TWD 6 TWD 7 TWD 9 TWD 10 TWD 6 TWD 11 TWD 8 TWD 8 TWD 8 TWD 6 TWD 13 TWD 9 TWD 6 TWD 5 TWD 9 TWD 7 TWD 5 TWD 4 TWD 6 TWD 8 TWD 6 TWD 7 TWD 4 TWD 9 TWD 9 TWD 5 TWD 6 TWD 5 TWD 8 TWD 6 TWD 5 LOCATION AV2

-0.28 AV3

-0.16 AV6

+0.14 AV7

+0.18 AV2

-0.26 AV7

+0.14 AV8

+0.17 AV3

-0.14 AV6

-0.23 AV7

+0.25 AV8

+0.25 AV7

+0.00 AV3

+0.00 AV7

+0.23 AV3

-0.14 AV3

-0.19 AV3

-0.12 AV3

-0.16 AV6

+0.18 AV8

-0.09 AV6

-0.30 AV7

+0.21 AV8

-0.21 AV1

+0.00 AV2

-0.23 AV3

-0.23 AV6

+0.14 AV7

+0.16 AV8

+0.19 AV3

-0.30 AV6

+0.16 AVI

-0.14 AV2

-0.16 AV3

-0.12 AV7

+0.21 AV8

+0.25 AV2

-0.14 AV3

-0.14 AV6

+0.23 AV7

+0.23 AV2

-0.09 AV3

-0.14 AV7

+0.23 AV7

+0.25 AV8

-0.16 AV6

+0.00 AV7

+0.00 AV7

+0.16 AV6

+0.14 AV2

-0.23 AVI

-0.23 AV2

-0.21 AV3

+0.00 AV6

+0.19 AV7

+0.21 AVl

-0.28 AV7

+0.19 AV8

+0.19 AVI

-0.12 AV3

+0.30 AV7

+0.25 AV8

+0.23 AV2

+0.00 AV3

+0.00 AV2

+0.00 AVl

+0.00 AV8

+0.00 AV7

+0.00 AV3

+0.00 AV3

+0.00 AV3

-0.14 AV3

-0.12 AV6

+0.00 AV6

-0.27 AVI

+0.00 AV3

+0.21 AV6

+0.16 AV7

+0.12 AV8

+0.00 AV8

+0.19 EXT EXT TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEN TEC TEH TEC TEH TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC TEC TEN TEC TEH TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC TEH TEC TEN TEC TEN TEC TEH TEC TEH TEN TEC TEN TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEC TEN TEC TEN TEC TEN TEC TEH TEC TEH TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC TEN TEC TEH TEC TEH TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEC TEN TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH UTIL 1

UTIL 2

=

---==

==

CAL #

4 4

4 4

4 4

4 61 61 61 61 62 62 61 61 61 58 23 7

5 4

4 4

4 4

4 4

4 4

3 3

61 61 61 61 61 61 61 61 61 61 61 61 61 5

6 6

5 5

5 4

4 4

4 4

3 3

3 61 61 61 61 61 62 62 62 62 62 62 62 57 24 6

5 4

4 4

4 4

3 LEG HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD NOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD NOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD NOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UDL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:33 Component: S/G B Page 5 of 48 Component: S/C 8 Page 5 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 5 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.06 0.23 0.41 0.57 0.17 61 10 0.19 0.33 0.33 61 12 0.19 0.12 0.32 0.14 61 14 0.21 0.44 61 16 0.13 0.20 61 18 0.12 61 52 0.09 61 156 0.10 61 158 0.16 0.41 0.41 61 160 0.22 0.09 62 11 0.31 0.14 0.34 0.12 0.17 62 13 0.18 0.23 0.29 62 17 0.18 0.15 62 23 0.17 62 43 0.09 62 131 0.13 62 139 0.18 62 155 0.11 62 157 0.15 0.13 0.12 0.19 62 159 0.12 0.20 0.14 0.09 63 12 0.12 0.13 63 14 0.14 0.27 0.11 63 16 0.14 0.14 63 18 0.14 63 150 0.13 63 152 0.11 63 154 0.10 63 156 0.21 0.14 0.28 0.09 63 158 0.13 0.34 0.34 64 11 0.39 64 13 0.27 64 15 0.17 0.12 64 23 0.22 64 27 0.15 64 31 0.10 64 107 0.14 64 153 0.14 0.16 0.12 64 155 0.10 64 157 0.27 0.19 64 159 0.18 DEG CHN 81 P2 131 P2 113 P2 109 P2 92 P2 122 P2 110 P2 117 P2 112 P2 104 P2 109 P2 82 P2 93 P2 114 P2 114 P2 104 P2 127 P2 105 P2 92 P2 95 P2 113 P2 109 P2 113 P2 126 P2 126 P2 105 P2 114 P2 115 P2 106 P2 97 P2 119 P2 120 P2 128 P2 78 P2 120 P2 99 P2 125 P2 128 P2 73 P2 95 P2 99 P2 72 P2 60 P2 86 P2 92 P2 60 P2 77 P2 100 P2 98 P2 113 P2 125 P2 118 P2 132 P2 113 P2 115 P2 61 P2 112 P2 136 P2 104 P2 102 P2 105 P2 114 P2 77 P2 106 P2 109 P2 114 P2 128 P2 125 P2 118 P2 122 P2 107 P2 129 P2 119 P2 70 P2 107 P2 83 P2 143 P2 90 P2 93 P2 119 P2 IND %TW TWD 3 TWD 10 TWD 15 TWD 19 TWD 8 TWD 8 TWD 13 TWD 13 TWD 8 TWD 5 TWD 12 TWD 6 TWD 8 TWD 15 TWD 6 TWD 8 TWD 5 TWD 4 TWD 5 TWD 7 TWD 14 TWD 14 TWD 9 TWD 4 TWD 11 TWD 6 TWD 12 TWD 5 TWD 7 TWD 8 TWD 10 TWD 12 TWD 8 TWD 7 TWD 7 TWD 4 TWD 5 TWD 7 TWD 5 TWD 6 TWD 5 TWD 5 TWD 8 TWD 5 TWD 8 TWD 6 TWD 4 TWD 6 TWD 6 TWD 6 TWD 11 TWD 5 TWD 6 TWD 6 TWD 6 TWD 5 TWD 5 TWD 4 TWD 8 TWD 6 TWD 11 TWD 4 TWD 5 TWD 12 TWD 12 TWD 15 TWD 10 TWD 7 TWD 5 TWD 9 TWD 8 TWD 6 TWD 6 TWD 6 TWD 7 TWO 5 TWD 4 TWD 10 TWD 7 TWD 8 LOCATION AV7

+0.16 AV6

+0.00 AV3

+0.00 AV2

+0.00 AVI

+0.00 AV2

-0.14 AV3

-0.16 AV7

+0.21 AV7

+0.00 AV6

+0.00 AV3

+0.00 AVI

+0.00 AV7

+0.00 AV3

+0.00 AV6

+0.00 AV3

+0.00 AV2

+0.00 AV3

-0.18 AV7

+0.00 AV2

-0.23 AV3

+0.26 AV6

-0.28 AV3

-0.23 AV7

+0.14 AV7

+0.00 AV6

+0.00 AV3

+0.00 AV2

+0.00 AVI

+0.00 AV7

+0.23 AV2

-0.18 AV3

-0.16 AV3

+0.00 AV6

-0.18 AV3

-0.14 AV3

-0.09 AV6

+0.16 AV6

+0.21 AV8

-0.21 AVI

-0.32 AV2

-0.25 AV7

+0.14 AV8

+0.00 AV2

+0.21 AV3

+0.23 AV6

-0.30 AV7

+0.14 AV3

-0.14 AV7

+0.23 AV2

-0.11 AV3

-0.16 AV3

+0.30 AV3

-0.14 AV6

+0.23 AV2

+0.09 AV6

-0.29 AV6

+0.16 AV6

+0.00 AV7

+0.23 AV6

+0.14 AV3

+0.20 AVI

+0.20 AV3

-0.21 AV6

+0.00 AV7

+0.19 AV3

-0.16 AV7

+0.00 AV3

+0.00 AV2

+0.00 AV3

-0.09 AV3

+0.00 AV3

+0.00 AV3

-0.02 AV7

+0.16 AV6

+0.18 AV8

-0.23 AVI

+0.00 AV2

-0.21 AV7

+0.16 AV3

-0.28 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL 3

3 3

3 3

61 61 61 62 62 62 62 62 62 62 62 60 23 6

4 4

4 3

3 62 62 62 62 62 61 61 61 61 61 58 26 20 18 5

4 4

4 4

4 4

4 4

61 61 61 61 61 61 61 59 5

5 6

5 5

5 5

4 4

4 61 62 62 62 57 30 30 26 5

5 5

6 4

4 3

  1. LEG HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT PROBE 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 61OUL 61OUL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610DUL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl 12/18/12 14:59:33 Component: S/G B Page 6 of 48, Enc. 8 Page 6 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC #278014 Rev. 0 ROW COL VOLTS 65 12 0.19 0.10 0.17 0.12 0.15 65 14 0.40 65 16 0.13 65 64 0.17 65 68 0.13 0.17 65 104 0.21 65 110 0.10 65 154 0.10 65 156 0.11 0.24 0.11 65 158 0.49 0.32 0.22 0.38 0.15 66 13 0.13 0.29 0.24 0.11 0.21 0.16 66 15 0.16 0.18 0.13 66 17 0.13 0.11 66 23 0.28 66 31 0.11 66 63 0.17 66 89 0.13 0.16 66 93 0.12 66 109 0.10 0.13 66 143 0.11 0.06 66 155 0.16 0.15 66 157 0.18 0.34 67 12 0.11 0.45 0.17 0.14 0.16 67 14 0.15 0.14 67 16 0.14 0.19 67 18 0.11 67 22 0.14 67 68 0.18 67 70 0.13 67 96 0.17 67 102 0.14 67 108 0.12 0.11 67 112 0.12 67 156 0.12 0.23 0.18 0.43 0.11 0.17 67 158 0.12 0.17 0.31 0.22 0.11 68 13 0.20 0.15 0.41 0.21 0.16 DEG CHN 114 P2 57 P2 96 P2 81 P2 83 P2 116 P2 128 P2 113 P2 120 P2 112 P2 127 P2 126 P2 96 P2 103 P2 117 P2 125 P2 107 P2 107 P2 82 P2 117 P2 90 P2 44 P2 105 P2 120 P2 79 P2 121 P2 120 P2 118 P2 119 P2 76 P2 88 P2 62 P2 110 P2 134 P2 133 P2 129 P2 125 P2 106 P2 85 P2 144 P2 139 P2 81 P2 69 P2 101 P2-83 P2 92 P2 103 P2 121 P2 130 P2 118 P2 115 P2 100 P2 106 P2 131 P2 118 P2 112 P2 123 P2 117 P2 119 P2 114 P2 135 P2 81 P2 99 P2 127 P2 64 P2 104 P2 97 P2 110 P2 132 P2 96 P2 117 P2 99 P2 128 P2 107 P2 83 P2 98 P2 133 P2 112 P2 77 P2 95 P2 IND %TW TWD 8 TWO 4 TWO 7 TWO 5 TWO 6 TWD 14 TWD 6 TWD 7 TWD 5 TWD 7 TWD 8 TWD 4 TWO 4 TWD 5 TWD 9 TWO 5 TWO 16 TWO 12 TWO 8 TWO 13 TWO 6 TWO 6 TWO 12 TWO 10 TWD 5 TWD 9 TWD 7 TWD 7 TWD 8 TWO 6 TWO 6 TWO 5 TWO 11 TWO 5 TWO 8 TWO 5 TWO 6 TWO 5 TWO 4 TWD 5 TWD 5 TWD 3 TWD 7 TWD 6 TWO 7 TWO 12 TWO 5 TWO 16 TWD 7 TWD 6 TWD 7 TWD 7 TWD 7 TWD 6 TWD 8 TWO 5 TWO 6 TWD 9 TWO 6 TWO 6 TWD 5 TWO 5 TWD 4 TWD 5 TWD 5 TWD 9 TWO 7 TWO 15 TWO 5 TWO 7 TWD 5 TWO 7 TWD 11 TWD 8 TWO 4 TWO 8 TWO 6 TWO 14 TWO 8 TWO 7 LOCATION AV8

+0.00 AV6

+0.00 AV3

+0.00 AV2

+0.00 AVI

+0.00 AV3

+0.00 AV6

+0.00 AV3

+0.00 AV6

+0.13 AV3

+0.00 AV6

+0.00 AV6

+0.18 AV6

+0.11 AV7

+0.00 AV3

+0.00 AV2

+0.00 AV2

-0.25 AV3

+0.21 AV6

-0.30 AV7

+0.18 AV8

+0.16 AVl

+0.30 AV2

+0.25 AV3

+0.28 AV6

+0.00 AV7

+0.25 AV8

+0.21 AV2

+0.05 AV3

-0.14 AV7

-0.14 AV2

+0.00 AV3

+0.25 AV3

-0.16 AV3

+0.00 AV6

+0.02 AV2

+0.00 AV3

+0.00 AV3

+0.00 AV3

+0.00 AV6

+0.00 AV6

+0.16 AV7

+0.11 AV7

-0.21 AVI

+0.19 AVI

-0.25 AV7

-0.23 AVI

-0.12 AV3

-0.14 AV6

+0.16 AV7

+0.23 AV8

+0.25 AV3

+0.25 AV6

-0.18 AV3

+0.00 AV6

+0.00 AV7

-0.18 AV3

-0.16 AV6

+0.09 AV3

+0.07 AV3

+0.00 AV3

+0.00 AV2

+0.00 AV3

+0.00 AV3

-0.05 AV8

+0.22 AV7

-0.25 AV6

-0.20 AV3

+0.20 AV2

-0.25 AVi

-0.27 AV2

+0.00 AV3

+0.26 AV7

+0.12 AV8

+0.16 AV6

+0.12 AV8

+0.00 AV7

+0.00 AV3

+0.00 AV2

+0.00 AVI

+0.00 EXT EXT TEN TEC TEN TEC TEN TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEC TEN TEC TEN TEC TEH TEC TEN TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEN TEH TEC TEN TEC TEH TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC TEC TEH TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC TEN TEC TEH TEC TEN TEN TEC TEN TEC TEH TEC TEH TEC TEN TEC TEN TEC TEN TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC TEH TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEH TEC TEN TEC TEN TEC TEN TEC TEH TEC UTIL 1

UTIL 2

CAL #

62 62 62 62 62 62 62 19 19 19 26 24 5

6 6

6 4

4 4

4 4

61 61 61 61 61 61 61 61 61 61 61 58 29 20 29 29 29 23 23 7

7 5

5 4

4 61 61 61 61 61 61 61 61 61 61 59 20 20 25 25 23 23 23 5

5 5

5 5

5 4

4 4

4 4

62 62 62 62 62 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 610UL 610UL 610DL 610UL 610UL 610OL 610UL 610UL 610UL 610UL 610UL 610DL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610OL 610OL 610UL 610UL 610UL 610UL 610DL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610TUL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:33 Component: S/G B Page 7 of 48 Component: S/C B Page 7 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 7 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 68 15 0.24 0.14 0.11 68 17 0.18 68 51 0.12 68 65 0.29 68 67 0.15 68 97 0.19 68 101 0.16 68 105 0.13 68 109 0.24 0.27 68 119 0.15 68 151 0.08 68 155 0.10 68 157 0.18 0.13 0.28 0.33 0.18 0.31 0.30 69 14 0.13 0.32 0.52 69 16 0.17 69 20 0.15 0.20 69 24 0.18 0.11 69 28 0.09 69 34 0.15 69 36 0.21 0.13 69 38 0.12 69 44 0.22 69 78 0.20 69 98 0.16 69 100 0.15 69 102 0.14 69 104 0.34 0.18 69 138 0.12 69 152 0.13 69 154 0.10 69 156 0.11 0.19 0.53 0.43 0.21 70 15 0.12 0.30 0.35 0.22 70 17 0.35 0.12 70 21 0.14 70 33 0.14 70 41 0.11 70 47 0.13 70 67 0.16 0.11 70 83 0.20 70 89 0.11 70 99 0.27 70 129 0.16 70 141 0.11 70 153 0.12 0.10 70 155 0.18 70 157 0.15 71 14 0.15 0.32 0.24 0.13 71 16 0.16 0.15 0.12 71 18 0.26 0.25 DEG CHN 110 P2 82 P2 113 P2 95 P2 86 P2 109 P2 136 P2 137 P2 96 P2 131 P2 136 P2 127 P2 133 P2 133 P2 97 P2 79 P2 84 P2 118 P2 105 P2 94 P2 102 P2 108 P2 98 P2 122 P2 116 P2 124 P2 108 P2 53 P5 122 P2 67 P2 87 P2 131 P2 143 P2 148 P2 92 P2 70 P5 73 P5 83 P5 128 P2 114 P2 132 P2 115 P2 90 P2 101 P2 53 P2 75 P2 116 P2 119 P2 114 P2 94 P2 126 P2 99 P2 131 P2 126 P2 107 P2 115 P2 79 P2 99 P2 128 P2 135 P2 147 P2 150 P2 102 P2 131 P2 124 P2 122 P2 78 P2 88 P2 97 P2 110 P2 93 P2 116 P2 124 P2 114 P2 118 P2 118 P2 137 P2 99 P2 110 P2 120 P2 IND %TW LOCATION TWD 9 AV7 TWD 6 AV3 TWD 5 AV2 TWD 7 AV3 TWD 6 AV3 TWD 11 AV3 TWD 6 AV3 TWD 7 AV6 TWD 6 AV6 TWD 5 AV3 TWD 10 AV6 TWD 10 AV3 TWD 6 AV3 TWD 4 AV7 TWD 5 AVI TWD 7 AVI TWD 5 AV2 TWD 10 AV3 TWD 12 AV6 TWD 7 AV8 TWD 11 AV7 TWD 11 AV7 TWD 6 AV7 TWD 12 AV6 TWD 17 AV3 TWO 7 AV3 TWD 6 AV2 TWD 7 AV4 TWD 8 AV2 TWD 5 AV3 TWD 5 AV3 TWD 6 AV3 TWD 9 AV6 TWD 6 AV3 TWD 6 AV3 TWD 7 AV3 TWD 6 AV3 TWD 5 AV4 TWD 6 AV3 TWD 6 AV3 TWD 12 AV6 TWD 7 AV3 TWD 5 AV6 TWD 6 AVI TWD 4 AV7 TWD 5 AV8 TWD 8 AV7 TWD 17 AV6 TWD 15 AV3 TWD 8 AVI TWD 5 AV2 TWD 12 AV3 TWD 14 AV6 TWD 9 AV7 TWD 13 AV3 TWD 5 AV6 TWD 6 AV3 TWD 6 AV3 TWD 5 AV3 TWD 5 AV3 TWD 8 AV6 TWD 5 AV7 TWD 9 AV3 TWD 5 AV2 TWD 9 AV3 TWD 6 AV3 TWD 5 AV3 TWD 5 AV8 TWD 5 AV7 TWD 7 AV6 TWD 6 AV3 TWD 7 AV2 TWD 13 AV3 TWD 10 AV7 TWD 6 AV8 TWD 7 AV3 TWD 7 AV6 TWD 5 AV8 TWD 11 AV3 TWD 11 AV4

+0.00

+0.00

+0.00

+0.00

-0.16

+0.00 r0.00

+0.00 r0.00 r0.00

-0.05

-0.07

-0.09

+0.00

+0.00

-0.30

-0.18

+0.21

+0.00

+0.16

+0.14

-0.28

+0.00

+0.00

+0.00

+0.00

+0.00

+1.29

+0.23

+0.32

+0.00

+0.27

+0.00

+0.00

+0.21

+13.04

-0.07

+1.33

-0.14

+0.00

+0.00

-0.07

-0.28

+0.00

+0.02

+0.12

-0.25

-0.23

+0.23

-0.21

+0.23

+0.25

+0.00

-0.12

+0.30

-0.21

+0.25

+0.11

+0.11

+0.18

+0.07

+0.07

+0.00

+0.00

+0.00

+0.00

-0.21

+0.00

+0.00

-0.23

-0.21

+0.21

+0.28

-0.16

+0.21

+0.25

-0.05

+0.21

+0.30

-0.23 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC UTIL 1

UTIL LAR LAR LAR 2

CAL #

62 62 62 62 24 19 19 26 26 26 24 24 22 6

6 4

4 4

4 4

4 4

62 62 62 62 60 60 58 58 30 29 27 27 28 25 17 26 26 26 26 26 18 6

5 5

5 5

5 5

61 61 61 61 61 61 59 29 27 23 20 20 18 29 25 19 8

6 6

5 4

61 61 61 61 61 61 61 61 61 LEG COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 6lOUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes) 12/18/12 14:59:33 Component: S/G B Page 8 of 48, Enc. 8 Page 8 of 48 PSL-ENG-SESJ-12-006 Rev, 0 EC # 278014 Rev, 0 QUERY: QueryMl ROW COL VOLTS 71 20 0.15 71 38 0.12 71 88 0.13 71 96 0.14 71 100 0.14 71 126 0.16 71 128 0.16 71 130 0.16 71 132 0.16 71 150 0.12 71 152 0.11 71 154 0.18 0.17 0.15 71 156 0.15 0.12 0.17 72 15 0.16 0.11 0.21 72 17 0.13 0.22 72 21 0.13 72 75 0.14 72 79 0.17 72 91 0.11 72 99 0.17 0.13 72 103 0.16 72 151 0.22 72 153 0.17 0.13 72 155 0.13 73 14 0.19 73 16 0.24 73 20 0.11 73 48 0.15 73 54 0.13 73 70 0.15 73 76 0.19 0.18 73 82 0.14 73 84 0.15 73 96 0.13 73 98 0.14 0.20 73 144 0.10 73 150 0.11 73 152 0.15 73 154 0.11 74 15 0.10 0.27 0.10 0.53 0.15 0.19 0.24 74 21 0.12 74 65 0.07 74 67 0.13 0.19 74 69 0.23 74 75 0.19 0.13 74 79 0.18 74 83 0.11 0.15 74 85 0.18 0.36 74 95 0.20 0.15 74 97 0.12 0.19 0.18 74 99 0.14 0.15 74 101 0.17 0.19 0.19 0.14 DEG CHN 109 P2 133 P2 94 P2 135 P2 131 P2 121 P2 83 P2 63 P2 82 P2 104 P2 145 P2 116 P2 121 P2 119 P2 85 P2 113 P2 108 P2 105 P2 125 P2 114 P2 117 P2 105 P2 130 P2 130 P2 116 P2 59 P2 132 P2 147 P2 137 P2 131 P2 85 P2 130 P2 99 P2 130 P2 134 P2 123 P2 92 P2 123 P2 133 P2 124 P2 135 P2 100 P2 115 P2 112 P2 134 P2 139 P2 137 P2 139 P2 134 P2 77 P2 152 P2 115 P2 70 P2 127 P2 148 P2 111 P2 110 P2 94 P2 86 P2 71 P2 117 P2 144 P2 91 P2 107 P2 92 P2 111 P2 136 P2 130 P2 125 P2 123 P2 121 P2 113 P2 125 P2 131 P2 120 P2 146 P2 130 P2 136 P2 120 P2 136 P2 IND %TW TWD 7 TWD 5 TWD 5 TWD 5 TWD 5 TWO 6 TWD 6 TWD 6 TWD 6 TWD 5 TWD 5 TWD 8 TWD 7 TWD 6 TWD 6 TWD 5 TWD 7 TWD 7 TWD 5 TWD 8 TWD 6 TWD 9 TWD 6 TWD 6 TWD 6 TWD 5 TWD 7 TWD 5 TWD 6 TWD 9 TWD 7 TWD 5 TWD 6 TWD 8 TWD 9 TWD 5 TWD 6 TWD 5 TWD 6 TWD 7 TWD 7 TWD 6 TWD 6 TWD 5 TWD 5 TWD 8 TWD 4 TWD 5 TWD 6 TWD 5 TWD 5 TWD 11 TWD 5 TWD 18 TWD 7 TWD 8 TWD 10 TWD 5 TWD 4 TWD 6 TWD 9 TWD 10 TWD 9 TWD 6 TWD 8 TWD 5 TWD 7 TWD 8 TWD 15 TWD 7 TWD 5 TWD 5 TWD 7 TWD 7 TWD 5 TWD 6 TWD 6 TWD 7 TWD 7 TWD 5 LOCATION AV2

+0.21 AV2

+0.00 AV2

+0.00 AV3

+0.00 AV3

+0.00 AV3

+0.00 AV3

+0.00 AV3

+0.00 AV6

+0.00 AVI

+0.00 AV3

-0.52 AV8

+0.00 AV7

+0.00 AV3

+0.00 AV7

+0.00 AV6

+0.00 AV3

+0.00 AV8

+0.00 AV7

+0.00 AV6

+0.00 AV6

+0.00 AV3

+0.00 AV3

+0.00 AV3

+0.00 AV3

+0.00 AV7

+0.00 AV3

+0.00 AV2

+0.00 AV3

+0.00 AV6

+0.00 AV8

-0.21 AV6

-0.11 AV8

+0.00 AV2

-0.39 AV6

+0.00 AV4

+0.00 AV3

+0.21 AV4

+0.25 AV5

+0.00 AV5

+0.00 AV3

+0.00 AV3

+0.00 AV3

+0.11 AV6

+0.00 AV6

+0.00 AV4

-0.05 AV3

-0.14 AV6

+0.00 AV7

+0.00 AV8

+0.17 AVI

-0.31 AV2

+0.25 AV3

+0.32 AV4

+0.09 AV6

-0.16 AV7

-0.16 AV8

+0.25 AV3

+0.21 AV2

-0.16 AV2

+0.07 AV6

+0.09 AV4

+0.00 AV6

+0.00 AV2

+0.02 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV4

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV7

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 EXT EXT TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL 59 27 29 25 25 19 19 19 19 5

5 6

6 6

6 6

6 62 62 62 62 62 60 17 17 30 26 26 26 6

5 5

6 61 62 60 23 21 19 17 17 17 15 26 26 26 8

6 6

5 61 61 61 61 61 61 61 59 20 20 20 20 18 18 18 18 18 16 16 27 27 25 25 25 25 25 25 25 25 25

  1. LEG COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:33 Component: S/G B Page 9 of 48 Component: S/S B Page 9 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 9 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 74 151 0.15 74 153 0.17 75 16 0.11 0.17 0.13 0.17 75 18 0.14 0.13 0.11 0.10 75 20 0.12 75 26 0.18 75 36 0.12 75 66 0.10 0.33 0.12 0.10 75 76 0.18 0.17 75 82 0.13 75 86 0.19 0.12 0.11 75 90 0.12 75 94 0.17 75 98 0.29 0.13 0.17 75 100 0.09 0.24 0.12 75 126 0.13 75 138 0.12 75 150 0.13 75 152 0.13 0.29 75 154 0.10 76 17 0.18 0.11 0.20 76 21 0.23 76 23 0.13 76 33 0.12 76 35 0.11 76 63 0.15 76 65 0.15 76 67 0.11 0.25 0.35 76 69 0.22 0.51 76 73 0.22 76 75 0.12 0.18 0.20 0.21 0.15 76 77 0.16 0.38 0.16 76 79 0.13 76 85 0.14 76 87 0.13 0.30 76 91 0.20 76 95 0.18 76 99 0.15 0.18 0.28 0.34 0.15 0.17 0.15 76 103 0.18 76 135 0.12 76 151 0.12 76 153 0.14 0.17 0.15 0.10 DEG CHN 94 P2 122 P2 83 P2 109 P2 136 P2 123 P2 101 P2 94 P2 133 P2 111 P2 139 P2 120 P2 90 P2 121 P2 129 P2 138 P2 75 P2 112 P2 117 P2 123 P2 130 P2 106 P2 139 P2 110 P2 128 P2 11 P2 132 P2 122 P2 127 P2 124 P2 101 P2 134 P2 118 P2 128 P2 92 P2 103 P2 119 P2 117 P2 105 P2 113 P2 144 P2 124 P2 77 P2 100 P2 114 P2 121 P2 147 P2 113 P2 131 P2 113 P2 122 P2 129 P2 138 P2 98 P2 126 P2 118 P2 83 P2 144 P2 125 P2 124 P2 113 P2 111 P2 86 P2 118 P2 104 P2 131 P2 137 P2 141 P2 134 P2 134 P2 149 P2 136 P2 126 P2 135 P2 137 P2 154 P2 118 P2 97 P2 88 P2 61 P2 IND %TW TWD 6 TWD 7 TWD 5 TWD 7 TWD 6 TWD 8 TWD 7 TWD 6 TWD 5 TWD 5 TWD 5 TWD 8 TWD 6 TWD 5 TWD 14 TWD 6 TWD 5 TWD 8 TWD 8 TWD 6 TWD 8 TWD 5 TWD 5 TWD 5 TWD 6 TWD 10 TWD 5 TWD 6 TWD 4 TWD 9 TWD 4 TWD 5 TWD 5 TWD 5 TWD 5 TWD 11 TWD 5 TWD 7 TWD 5 TWD 8 TWD 10 TWD 5 TWD 7 TWD 6 TWD 6 TWD 6 TWD 5 TWD 9 TWD 12 TWD 8 TWD 16 TWD 8 TWD 5 TWD 7 TWD 7 TWD 8 TWD 6 TWD 6 TWD 12 TWD 6 TWD 5 TWD 5 TWD 5 TWD 11 TWD 8 TWD 8 TWD 6 TWD 7 TWD 10 TWD 12 TWD 6 TWD 7 TWO 6 TWD 7 TWD 5 TWD 5 TWD 6 TWD 7 TWD 6

TWD 4 LOCATION AV6

-0.07 AV4

+0.00 AVI

-0.16 AV3

+0.21 AV7

+0.00 AV8

+0.21 AV3

+0.25 AV4

+0.25 AV5

-0.16 AV8

+0.21 AV5

-0.12 AV8

+0.07 AV4

-0.16 AV2

+0.07 AV3

+0.05 AV4

-0.02 AV5

-0.12 AV5

-0.14 AV4

+0.05 AV5

-0.09 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV4

+0.00 AV6

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV5

+0.12 AV4

+0.00 AV3

-0.05 AV5

-0.14 AV4

+0.16 AV7

+0.00 AV8

+0.00 AV6

+0.00 AV3

+0.00 AV5

+0.00 AV3

+0.07 AV4

+0.00 AV5

-0.14 AV7

+0.00 AV5

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV7

+0.00 AV6

+0.00 AV5

-0.14 AV4

+0.00 AV2

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV6

+0.14 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV3

+0.00 AV2

+0.00 AV8

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

-0.02 AV2

+0.00 AV3

-0.07 AV4

+0.00 AV6

+0.00 AV7

-0.23 AV5

-0.18 AV4

+0.14 AV3

+0.21 EXT EXT TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL #

5 6

61 61 61 61 61 61 61 61 59 58 28 20 20 20 20 18 18 18 29 29 29 29 27 25 25 25 25 25 25 19 17 5

5 5

6 62 62 62 60 57 30 28 19 19 19 19 19 19 19 17 17 17 17 17 17 17 17 17 17 15 30 30 30 28 26 26 26 26 26 26 26 26 18 6

5 5

5 5

LEG HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 61OUL 610UL 610UL 6100L 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610OL 610UL 610UL 610UL 610TUL 610UL 610UL 610UL 61OUL 610OL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:33 Component: S/G B Page 10 of 48 Bobbin AVB Wear Indications 1% to 19%

Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 10 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 77 16 0.18 77 20 0.30 0.28 0.16 77 24 0.16 77 46 0.09 77 62 0.16 77 68 0.14 77 70 0.14 77 76 0.25 0.17 77 78 0.13 77 80 0.14 77 82 0.19 0.14 77 86 0.16 0.15 77 90 0.12 77 92 0.15 77 94 0.14 0.13 0.21 77 96 0.16 0.20 0.14 0.16 77 98 0.14 77 104 0.19 0.14 77 106 0.14 77 140 0.12 77 142 0.16 0.07 77 150 0.10 77 152 0.13 0.14 0.16 78 17 0.14 0.10 78 19 0.15 78 23 0.12 0.15 78 25 0.13 78 27 0.16 78 31 0.12 78 49 0.15 78 69 0.15 0.12 0.10 78 75 0.23 0.16 0.25 0.27 78 77 0.14 0.12 78 83 0.13 0.19 0.25 78 85 0.15 0.30 78 89 0.14 0.14 78 95 0.26 0.17 78 97 0.18 0.19 0.14 78 99 0.16 0.13 0.41 0.48 78 101 0.14 0.15 0.12 0.17 0.18 78 105 0.20 78 109 0.21 78 151 0.16 78 153 0.11 DEG CHN 143 P2 140 P2 117 P2 129 P2 107 P2 48 P2 137 P2 139 P2 113 P2 110 P2 132 P2 88 P2 134 P2 139 P2 137 P2 68 P2 114 P2 121 P2 105 P2 141 P2 135 P2 112 P2 134 P2 125 P2 135 P2 126 P2 101 P2 104 P2 141 P2 128 P2 114 P2 137 P2 79 P2 154 P2 94 P2 131 P2 118 P2 101 P2 80 P2 100 P2 131 P2 154 P2 126 P2 88 P2 108 P2 140 P2 100 P2 142 P2 63 P2 101 P2 135 P2 108 P2 116 P2 86 P2 126 P2 113 P2 118 P2 114 P2 124 P2 120 P2 114 P2 118 P2 127 P2 125 P2 108 P2 115 P2 123 P2 112 P2 142 P2 124 P2 124 P2 146 P2 135 P2 116 P2 128 P2 118 P2 102 P2 119 P2 131 P2 119 P2 IND %TW LOCATION TWD 8 AV8

+0.23 TWD 12 AV6

+0.00 TWD 11 AV5

+0.00 TWD 7 AVI

+0.00 TWD 7 AV3

+0.23 TWD 4 AV4

+0.16 TWD 6 AV5

+0.00 TWD 5 AV7

+0.00 TWD 5 AV3

+0.00 TWD 9 AV5

+0.00 TWD 6 AV4

+0.00 TWD 5 AV5

+0.00 TWD 5 AV4

+0.00 TWD 7 AV5

+0.00 TWD 6 AV3

+0.00 TWD 7 AV4

+0.00 TWD 6 AV5

+0.00 TWD 5 AV7

+0.00 TWD 6 AV7

+0.00 TWD 6 AV2

+0.00 TWD 6 AV4

+0.00 TWD 8 AV6

+0.00 TWD 6 AV7

+0.00 TWD 8 AV5

+0.00 TWO 5 AV3

+0.00 TWD 6 AV2

-0.09 TWD 5 AV4

-0.02 TWD 8 AV5

+0.00 TWD 6 AV4

+0.00 TWD 6 AV6

+0.00 TWD 5 AV5

-0.21 TWD 7 AV4

+0.00 TWD 3 AV2

-0.23 TWD 5 AV6

+0.00 TWD 6 AV7

+0.00 TWD 6 AV4

+0.00 TWD 7 AV3

+0.00 TWD 6 AV3

+0.23 TWD 5 AV8

+0.23 TWD 6 AV4

+0.25 TWD 5 AV2

+0.00 TWD 6 AV3

-0.02 TWD 6 AV5

+0.00 TWD 7 AV5

+0.00 TWD 5 AV4

+0.00 TWD 6 AV3

+0.00 TWD 7 AV3

+0.07 TWD 6 AV4

+0.02 TWD 5 AV5

-0.14 TWD 10 AV5

+0.00 TWD 7 AV4

+0.00 TWD 11 AV2

+0.00 TWD 11 AV3

+0.09 TWD 7 AV5

+0.25 TWD 5 AV4

+0.16 TWD 6 AV6

+0.00 TWD 8 AV5

+0.00 TWD 11 AV4

+0.00 TWD 7 AV4

+0.28 TWD 13 AV3

+0.00 TWD 6 AV2

+0.00 TWD 5 AV6

+0.00 TWD 9 AV4

+0.00 TWD 6 AV5

+0.00 TWD 7 AV2

+0.00 TWD 7 AV3

+0.00 TWD 5 AV4

+0.00 TWD 6 AV2

+0.00 TWD 5 AV3

+0.00 TWD 13 AV4

+0.00 TWD 15 AV6

+0.00 TWD 5 AVI

+0.00 TWD 6 AV2

+0.00 TWD 5 AV4

+0.00 TWD 6 AV5

+0.00 TWD 7 AV6

+0.00 TWD 7 AV4

+0.00 TWD 8 AV5

+0.00 TWD 7 AV6

+0.00 TWD 5 AVI

+0.00 EXT EXT UTIL 1

UTIL 2

TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH CAL #

61 60 60 60 58 23 19 19 19 17 17 17 17 17 17 30 30 30 30 28 28 28 26 26 26 26 26 26 26 26 8

8 8

6 6

6 6

61 61 59 58 58 58 58 29 23 20 20 20 18 18 18 18 18 18 18 18 18 16 16 29 29 27 27 25 25 25 25 25 25 25 25 25 25 25 25 25 23 5

6 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 61OUL 610UL 61OUL 610UL 61OUL 61OUL 61OUL 61OUL 61OUL 610UL 61OUL 61OUL 61OUL 61DUL 61OUL 61OUL 610UL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 61OUL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:33 Component: S/G B Page 11 of 48 Component: S/C B Page 11 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 11 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 79 18 0.15 0.10 0.12 79 20 0.19 0.23 79 22 0.14 79 24 0.12 0.12 79 26 0.12 79 28 0.13 0.12 79 32 0.13 79 62 0.18 0.13 0.11 79 64 0.15 79 66 0.12 0.14 79 70 0.15 79 72 0.13 79 76 0.11 79 80 0.14 79 82 0.23 79 84 0.19 79 86 0.20 0.22 0.13 0.14 0.15 79 88 0.14 0.14 0.14 79 90 0.12 79 94 0.15 0.13 0.17 79 96 0.18 0.34 0.20 0.14 0.33 79 98 0.27 0.28 0.55 79 100 0.20 0.26 79 104 0.23 0.18 0.09 79 108 0.12 79 136 0.11 79 150 0.11 79 152 0.10 0.08 80 21 0.17 0.13 0.14 80 23 0.12 80 25 0.13 80 27 0.12 80 35 0.13 80 37 0.19 80 59 0.15 80 65 0.16 0.12 80 67 0.12 80 69 0.12 0.10 0.21 80 71 0.17 0.15 80 73 0.13 0.17 80 75 0.22 0.27 0.17 80 77 0.19 0.25 0.30 0.21 DEG CHN 123 P2 103 P2 112 P2 99 P2 109 P2 101 P2 133 P2 105 P2 38 P2 135 P2 112 P2 80 P2 117 P2 117 P2 138 P2 113 P2 149 P2 94 P2 80 P2 135 P2 74 P2 133 P2 114 P2 115 P2 121 P2 118 P2 118 P2 109 P2 116 P2 108 P2 123 P2 115 P2 121 P2 128 P2 88 P2 128 P2 116 P2 117 P2 132 P2 125 P2 106 P2 130 P2 133 P2 120 P2 136 P2 130 P2 114 P2 125 P2 133 P2 121 P2 138 P2 90 P2 149 P2 83 P2 152 P2 159 P2 141 P2 88 P2 141 P2 117 P2 123 P2 118 P2 115 P2 120 P2 147 P2 117 P2 125 P2 108 P2 107 P2 125 P2 127 P2 129 P2 99 P2 120 P2 121 P2 129 P2 142 P2 108 P2 114 P2 119 P2 IND %TW TWD 7 TWD 5 TWD 6 TWD 8 TWD 9 TWD 6 TWD 5 TWD 5 TWD 5 TWD 6 TWD 5 TWD 7 TWD 9 TWD 6 TWD 6 TWD 7 TWD 6 TWD 7 TWD 7 TWD 6 TWD 5 TWD 7 TWD 10 TWD 9 TWD 8 TWD 8 TWD 5 TWD 6 TWD 6 TWD 5 TWD 5 TWD 5 TWD 5 TWD 6 TWD 5 TWD 6 TWD 7 TWD 11 TWD 7 TWD 5 TWD 11 TWD 9 TWD 10 TWD 16 TWD 7 TWD 9 TWD 8 TWD 7 TWD 3 TWD 5 TWD 5 TWD 5 TWD 4 TWD 3 TWD 7 TWD 6 TWD 6 TWD 5 TWD 6 TWD 5 TWD 7 TWD 8 TWD 8 TWD 6 TWD 5 TWD 5 TWD 5 TWD 4 TWD 8 TWD 7 TWD 6 TWD 5 TWD 6 TWD 8 TWD 10 TWD 6 TWD 7 TWD 9 TWD 10 TWD 8 LOCATION AV6

+0.00 AV7

-0.14 AV8

+0.18 AVi

+0.21 AV5

-0.12 AV4

+0.19 AV2

+0.14 AV3

+0.25 AVI

-0.09 AV4

+0.00 AVI

+0.16 AV4

+0.00 AV3

+0.05 AV4

+0.07 AV5

+0.12 AV3

+0.07 AV3

+0.07 AV4

+0.18 AV5

+0.30 AV5

+0.12 AVS

-0.11 AV5

+0.00 AV5

+0.00 AV3

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV2

+0.00 AV3

+0.00 AV5

+0.00 AV6

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AVI

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV4

+0.00 AV5

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AVI

-0.27 AV2

+0.00 AVI

-0.23 AV4

+0.00 AV2

+0.00 AVI

+0.00 AV4

+0.21 AV4

+0.05 AVI

-0.07 AV4

+0.18 AV5

+0.00 AV4

-0.18 AV5

+0.00 AV4

+0.00 AV2

+0.00 AV5

+0.00 AV4

+0.00 AV2

+0.00 AV6

+0.00 AV5

+0.00 AV7

+0.00 AV4

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEHE TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC UTIL 1

UTIL 2

CAL #

61 61 61 59 59 59 57 57 58 29 29 30 20 20 20 20 20 20 20 20 18 18 18 16 29 29 29 29 29 29 29 29 29 27 27 27 25 25 25 25 25 25 25 25 25 25 25 25 25 23 17 5

5 5

60 60 60 57 57 57 28 27 22 19 19 19 19 19 19 19 19 17 17 17 17 17 17 17 17 17 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl 12/18/12 14:59:34 Component: S/G B Page 12 of 48, Enc. 8 Page 12 of 48 PSL-ENG-SESJ-1 2-COG Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 80 83 0.25 0.14 80 85 0.17 0.21 0.20 80 87 0.23 0.18 0.16 0.34 0.18 80 89 0.15 80 91 0.18 80 93 0.18 80 95 0.13 0.19 0.12 80 97 0.13 0.16 80 99 0.16 0.23 0.20 0.15 80 101 0.17 0.17 0.23 80 103 0.14 80 105 0.10 0.23 0.14 80 125 0.12 80 135 0.16 0.15 80 145 0.14 80 151 0.12 0.09 0.10 81 18 0.15 81 28 0.14 0.13 81 30 0.12 81 36 0.14 81 38 0.16 81 66 0.13 0.14 81 70 0.18 81 72 0.20 81 74 0.17 0.15 0.18 81 76 0.26 0.16 81 78 0.17 0.16 0.13 0.18 81 80 0.31 0.34 81 82 0.16 0.25 0.20 0.40 81 84 0.16 0.22 0.22 81 86 0.42 0.29 0.16 81 88 0.16 0.19 0.15 0.17 81 92 0.15 0.19 81 94 0.15 81 96 0.25 0.17 0.16 0.14 81 98 0.14 0.18 DEG CHN 126 P2 99 P2 138 P2 126 P2 117 P2 118 P2 117 P2 105 P2 113 P2 97 P2 98 P2 93 P2 96 P2 128 P2 126 P2 88 P2 127 P2 95 P2 121 P2 138 P2 129 P2 142 P2 133 P2 138 P2 139 P2 127 P2 155 P2 141 P2 149 P2 143 P2 143 P2 138 P2 122 P2 123 P2 151 P2 155 P2 32 P2 99 P2 114 P2 112 P2 142 P2 131 P2 139 P2 134 P2 108 P2 120 P2 117 P2 128 P2 125 P2 132 P2 133 P2 127 P2 110 P2 132 P2 87 P2 120 P2 107 P2 139 P2 123 P2 130 P2 109 P2 120 P2 117 P2 114 P2 115 P2 115 P2 92 P2 95 P2 108 P2 93 P2 104 P2 134 P2 117 P2 125 P2 131 P2 145 P2 125 P2 143 P2 136 P2 142 P2 IND %TW LOCATION TWD 9 AV4

+0.00 TWD 5 AV3

+0.00 TWD 6 AV7

+0.00 TWD 8 AV4

+0.07 TWD 7 AV3

+0.00 TWD 9 AV2

+0.00 TWD 7 AV3

+0.00 TWD 7 AV4

+0.00 TWD 12 AV5

+0.00 TWD 7 AV6

+0.00 TWD 6 AV3

+0.00 TWD 7 AV3

+0.00 TWD 7 AV3

+0.00 TWD 6 AV4

+0.00 TWD 8 AV5

+0.00 TWD 5 AV2

+0.12 TWD 5 AV5

+0.00 TWD 6 AV2

+0.00 TWD 6 AV6

+0.00 TWD 9 AV5

+0.00 TWD 8 AV4

+0.00 TWD 6 AV2

-0.12 TWD 7 AV4

+0.00 TWD 7 AV6

+0.00 TWD 9 AV5

+0.00 TWD 5 AV6

+0.00 TWD 4 AV5

-0.12 TWD 9 AV4

-0.09 TWD 5 AV6

-0.07 TWD 5 AV5

-0.21 TWD 6 AV5

-0.11 TWD 6 AV3

-0.18 TWD 6 AV4

-0.05 TWD 5 AVI

+0.00 TWD 4 AV6

+0.00 TWD 4 AV2

+0.00 TWD 7 AV6

+0.51 TWD 6 AVl

+0.21 TWD 6 AV4

+0.09 TWD 6 AV4

+0.25 TWD 6 AV4

+0.05 TWD 7 AV4

-0.02 TWD 5 AV6

+0.00 TWD 6 AV5

+0.00 TWD 7 AV5

+0.00 TWD 8 AV5

+0.00 TWD 6 AV4

+0.00 TWD 6 AV3

+0.00 TWD 7 AV2

+0.00 TWD 9 AV5

+0.00 TWD 6 AV4

+0.00 TWD 6 AV7

-0.18 TWD 6 AV6

+0.00 TWD 5 AV5

+0.00 TWD 7 AV4

+0.00 TWD 11 AV5

+0.00 TWD 11 AV4

+0.00 TWD 6 AV6

+0.00 TWD 9 AV5

+0.00 TWD 7 AV4

+0.00 TWD 13 AV3

+0.00 TWD 6 AV5

+0.00 TWD 8 AV4

-0.02 TWD 8 AV3

+0.02 TWD 14 AV4

+0.00 TWD 11 AV5

+0.00 TWD 6 AV6

+0.00 TWD 7 AV2

+0.00 TWD 7 AV3

+0.00 TWD 6 AV4

+0.00 TWD 7 AV5

+0.00 TWD 6 AV2

+0.00 TWD 7 AV4

+0.00 TWD 6 AV4

+0.00 TWD 9 AV7

+0.00 TWD 7 AV6

+0.00 TWD 6 AV4

+0.00 TWD 6 AV2

-0.07 TWD 6 AV5

+0.00 TWD 7 AV4

+0.00 EXT EXT TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL # LEG 17 COLD 17 COLD 15 COLD 15 COLD 15 COLD 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 28 HOT 28 HOT 28 HOT 28 HOT 26 HOT 26 HOT 26 HOT 26 HOT 26 HOT 26 HOT 26 HOT 26 HOT 26 HOT 26 HOT 26 HOT 26 HOT 26 HOT 20 HOT 18 HOT 18 HOT 8

HOT 6

HOT 6

HOT 6

HOT 61 COLD 57 COLD 57 COLD 30 COLD 27 COLD 27 COLD 19 COLD 19 COLD 19 COLD 19 COLD 17 COLD 17 COLD 17 COLD 17 COLD 17 COLD 17 COLD 17 COLD 17 COLD 17 COLD 17 COLD 17 COLD 17 COLD 17 COLD 17 COLD 17 COLD 15 COLD 15 COLD 15 COLD 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 30 HOT 29 HOT 29 HOT 28 HOT 26 HOT 26 HOT 26 HOT 26 HOT 26 HOT 26 HOT PROBE 61OUL 61OUL 61OUL 61OUL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 61OUL 61OUL 61OUL 61OUL 610UL 610UL 61OUL 61OUL 61OUL 61OUL 61OUL 610UL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 610UL 610UL 61OUL 61OUL 61OUL 610UL 61OUL 61OUL 61OUL 61OUL 610UL 61OUL 610UL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 61OUL 610UL 610UL 610UL 61OUL 61OUL 61OUL 61OUL 610UL 61OUL 61OUL 61OUL 610UL 610UL 610UL 61OUL 610UL 61OUL 61OUL 61OUL 61OUL 610UL 61OUL

AREVA NP Inc.

Customer Name: St Lucie 2 Replacement 12/18/12 14:59:34 Component: S/G B Page 13 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 13 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL.

VOLTS 0.18 0.21 81 100 0.13 0.15 81 150 0.12 82 21 0.17 0.12 82 23 0.13 0.14 0.14 82 25 0.22 82 27 0.15 82 29 0.14 82 31 0.13 82 33 0.19 82 41 0.14 82 69 0.10 82 73 0.15 0.15 82 75 0.29 0.25 0.19 82 77 0.14 82 81 0.16 82 83 0.27 0.14 0.13 82 85 0.15 0.18 0.33 82 87 0.14 0.20 0.22 0.25 82 89 0.14 82 91 0.12 82 95 0.15 0.24 0.28 0.17 82 97 0.29 0.28 0.30 0.31 0.13 82 99 0.15 0.12 0.13 0.42 0.45 0.16 82 105 0.14 0.14 82 109 0.10 0.17 82 149 0.11 83 20 0.15 83 26 0.15 83 28 0.16 83 36 0.09 83 58 0.18 83 64 0.12 83 66 0.14 0.10 83 70 0.15 0.19 83 76 0.12 0.32 0.31 83 78 0.16 0.14 0.18 0.14 83 80 0.25 0.39 0.24 0.21 83 84 0.31 0.22 0.26 DEG 129 136 131 124 110 147 128 143 117 144 117 117 145 135 107 142 110 137 135 100 108 127 81 80 88 79 136 119 131 109 120 125 110 108 72 110 123 132 121 127 ill 120 128 114 125 131 116 94 123 125 140 103 126 ill 92 134 109 142 107 90 86 88 107 135 104 129 86 114 108 106 69 110 101 100 109 128 117 119 99 120 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWD 7 TWD 8 TWD 5 TWD 6 TWD 5 TWD 7 TWD 5 TWD 6 TWD 6 TWD 6 TWD 9 TWD 6 TWD 6 TWD 6 TWD 7 TWD 6 TWD 5 TWD 7 TWD 7 TWD 12 TWD 11 TWD 8 TWD 6 TWD 7 TWD 11 TWD 6 TWD 6 TWD 7 TWD 8 TWD 14 TWD 6 TWD 8 TWD 8 TWD 9 TWD 5 TWD 5 TWD 5 TWD 9 TWD 10 TWD 6 TWD 10 TWD 10 TWD 10 TWD 11 TWD 5 TWO 6 TWD 4 TWD 5 TWD 13 TWD 14 TWD 6 TWD 5 TWD 5 TWD 4 TWD 6 TWD 5 TWD 7 TWD 6 TWD 7 TWD 5 TWD 9 TWD 6 TWD 7 TWD 5 TWD 7 TWD 9 TWD 6 TWD 13 TWD 13 TWD 7 TWD 7 TWD 8 TWD 6 TWD 11 TWD 15 TWD 10 TWD 9 TWD 13 TWD 10 TWD 11 LOCATION AV2

+0.00 AVI

+0.00 AV5

+0.00 AV2

-0.09 AVI

+0.00 AV3

+0.05 AV4

+0.02 AVI

+0.00 AV3

+0.00 AV4

+0.18 AV4

+0.09 AV4

+0.05 AV4

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV4

-0.14 AV2

+0.00 AV7

+0.20 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV6

+0.25 AV5

+0.30 AV6

+0.00 AV5

-0.11 AV3

-0.07 AV6

+0.00 AV4

+0.00 AV3

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV4

+0.00 AV6

+0.00 AVI

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV7

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV4

+0.00 AV5

+0.00 AV3

+0.00 AV4

+0.00 AV2

-0.09 AV3

+0.05 AV4

+0.09 AV5

+0.09 AV5

+0.00 AV4

+0.07 AV5

+0.09 AV5

+0.19 AV2

+0.09 AV5

+0.23 AV6

+0.11 AV7

+0.27 AV6

+0.00 AV5

+0.23 AV3

+0.00 AV5

+0.27 AV6

+0.00 AV7

+0.02 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV6

+0.00 AV5

+0.00 AV3

+0.00 EXT EXT UTIL 1

UTIL 2

TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC CAL 26 26 26 26 6

59 59 58 58 58 58 58 29 29 29 27 20 18 18 18 18 18 18 18 18 18 18 16 16 16 29 29 29 29 29 29 27 27 27 27 25 25 25 25 25 25 25 25 25 25 25 25 25 23 23 5

59 58 58 28 22 20 20 20 20 20 18 18 18 18 18 18 18 18 18 18 18 16 16 16

  1. LEG HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:34 Component: S/G B Page 14 of 48 Component: S/C B Page 14 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 14 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 83 86 0.35 0.15 0.12 0.14 83 88 0.17 0.29 0.13 0.17 0.15 83 90 0.13 0.13 83 92 0.16 83 94 0.27 83 96 0.13 0.12 83 98 0.18 0.16 0.29 0.29 83 100 0.21 0.22 0.14 83 128 0.15 83 136 0.12 83 140 0.08 83 144 0.11 84 21 0.16 84 23 0.12 0.21 0.15 84 25 0.13 0.13 84 27 0.12 84 29 0.12 0.08 84 31 0.11 84 33 0.15 84 67 0.12 0.15 0.14 0.13 84 73 0.16 0.26 0.12 0.18 84 75 0.14 0.23 0.28 0.14 84 77 0.18 0.25 0.13 0.14 84 79 0.13 84 81 0.28 84 83 0.15 0.15 0.36 84 85 0.27 0.30 0.24 84 87 0.16 0.31 0.25 0.38 0.18 84 89 0.36 84 93 0.15 0.12 84 95 0.21 0.44 0.37 84 97 0.13 0.18 0.15 0.26 84 99 0.15 0.26 0.33 0.34 DEG 114 ill 106 122 88 94 100 92 118 136 100 98 117 137 140 90 131 122 130 118 120 118 117 122 109 124 145 139 127 105 96 143 109 144 124 104 137 143 108 123 134 117 116 123 132 148 123 117 61 117 132 105 142 135 115 93 109 98 123 129 118 92 108 ill 113 136 117 133 133 ill 118 131 143 140 137 135 139 133 121 123 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWD 12 TWD 6 TWD 5 TWD 6 TWD 7 TWD 10 TWD 5 TWD 7 TWD 6 TWD 5 TWD 5 TWD 6 TWD 9 TWD 5 TWD 5 TWD 7 TWD 6 TWD.10 TWD 10 TWD 8 TWD 8 TWD 5 TWD 6 TWD 5 TWD 4 TWD 5 TWD 7 TWD 5 TWD 8 TWD 6 TWD 6 TWD 5 TWD 5 TWD 5 TWD 4 TWD 6 TWD 8 TWD 5 TWD 6 TWD 6 TWD 5 TWD 6 TWD 9 TWD 5 TWD 7 TWD 5 TWD 8 TWD 10 TWD 6 TWD 7 TWD 9 TWD 5 TWD 5 TWD 5 TWD 10 TWD 6 TWD 6 TWD 12 TWD 9 TWD 10 TWD 9 TWD 6 TWD 11 TWD 9 TWD 13 TWD 7 TWD 13 TWD 6 TWD 5 TWD 9 TWD 15 TWD 14 TWD 5 TWD 7 TWD 6 TWD 10 TWD 6 TWD 10 TWD 12 TWD 12 LOCATION AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV5

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV4

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV6 o0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV4

+0.00 AV3

+0.00 AV5

-0.16 AV3

-0.18 AV3

+0.00 AVI

+0.09 AV3

+0.09 AV4

+0.00 AVI

+0.25 AV4

+0.07 AVI

+0.18 AV4

+0.07 AVl

+0.16 AV2

+0.00 AV4

+0.00 AV7

+0.00 AV4

+0.00 AV2

+0.00 AVI

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV8

+0.00 AV5

+0.07 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV5

+0.09 AV4

+0.09 AV3

+0.05 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV6

+0.00 AV2

+0.00 AVI

+0.00 AVI

+0.00 AV2

+0.00 AV3

+0.00 AV7

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL #

29 29 29 29 29 29 29 29 29 29 29 30 27 25 25 25 25 25 25 25 25 25 19 17 7

7 60 57 57 57 57 57 57 57 57 30 30 19 19 19 19 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 15 15 15 30 30 30 30 30 30 28 28 28 28 28 26 26 26 26 26 26 26 26 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TDL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UDL 610UDL 610UL 610TDL 610UL 610UL 610UL 610UL 610TDL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 6100L 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:34 Component: S/G B Page 15 of 48 Component: S/C B Page 15 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 15 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.26 0.16 84 101 0.13 0.30 0.37 0.20 84 103 0.15 84 105 0.24 84 149 0.18 0.16 85 24 0.12 0.14 85 26 0.15 85 28 0.15 0.14 85 30 0.12 85 36 0.12 85 66 0.12 85 70 0.16 0.26 85 76 0.12 0.34 85 78 0.21 0.26 0.17 85 82 0.14 85 86 0.18 0.23 0.20 85 90 0.15 85 92 0.30 0.20 0.12 85 94 0.13 85 96 0.14 0.20 0.17 0.15 85 98 0.15 0.20 0.16

'0.12 0.21 85 100 0.37 0.27 0.14 85 102 0.15 85 104 0.19 0.20 85 106 0.14 0.18 86 23 0.18 0.20 0.18 86 25 0.11 0.17 86 71 0.17 86 73 0.24 0.15 86 75 0.32 0.13 0.37 86 79 0.19 86 81 0.38 0.12 86 83 0.18 0.10 0.24 0.18 86 85 0.40 0.46 0.52 0.12 86 87 0.25 0.26 0.31 0.39 0.20 0.15 86 89 0.13 DEG 137 132 138 128 125 126 125 119 140 132 129 139 121 126 97 134 112 77 124 103 121 114 133 108 144 ill 90 115 91 104 124 115 126 82 106 132 112 128 135 139 121 128 132 139 136 119 127 141 145 138 130 121 132 128 85 127 123 104 112 116 92 ill 117 117 121 99 122 116 103 106 108 112 109 103 Iil 115 112 100 79 120 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWD 10 TWD 6 TWD 5 TWD 11 TWD 13 TWD 8 TWD 6 TWD 9 TWD 7 TWD 7 TWD 5 TWD 6 TWD 6 TWD 6 TWD 6 TWD 7 TWD 5 TWD 5 TWD 6 TWD 10 TWD 5 TWD 11 TWD 8 TWD 9 TWD 6 TWD 5 TWD 7 TWD 9 TWD 8 TWD 6 TWD 11 TWD 8 TWD 5 TWD 6 TWD 6 TWD 8 TWD 7 TWD 6 TWD 6 TWD 8 TWD 6 TWO 5 TWD 8 TWD 13 TWD 10 TWD 6 TWD 6 TWD 8 TWD 8 TWD 6 TWD 7 TWD 8 TWD 8 TWD 8 TWD 5 TWD 7 TWD 8 TWD 10 TWD 7 TWD 13 TWD 6 TWD 14 TWD 8 TWD 15 TWD 6 TWD 8 TWD 5 TWD 10 TWD 8 TWD 16 TWD 17 TWD 19 TWD 6 TWD 9 TWD 10 TWD 11 TWD 13 TWD 8 TWD 6 TWD 5 LOCATION AV3.

+0.00..

AV3

+0.00 AV2

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV2

+0.00 AV5

+0.00 AV4

-0.05 AV3

+0.00 AV2

+0.00 AVI

+0.05 AV4

+0.07 AV4

+0.09 AV4

+0.05 AV5

+0.21 AV5

+0.00 AV5

+0.00 AV4

+0.00 AV6

.+0.00 AV5

+0.00 AV5

+0.00 AV3

+0.00 AV7

+0.16 AV6

+0.00 AV5

+0.00 AV6

+0.00 AV4

+0.00 AVS

+0.00 AV6

+0.00 AV5

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV4

+0.00 AVl

+0.00 AV2

+0.00 AV4

+0.00 AVS

+0.00 AV7

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV4

+0.00 AV4

+0.00 AV3

+0.00 AV4

-0.09 AV3

+0.00 AVI

+0.00 AV2

+0.05 AV5

+0.12 AVI

+0.16 AV4

+0.02 AV3

+0.07 AV4

+0.00 AVI

+0.00 AV5

+0.00 AV4

-0.14 AV2

+0.00 AV3

+0.00 AV5

+0.00 AV2

+0.05 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV2

+0.02 AV3

+0.09 AV4

+0.09 AV7

+0.07 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV8

+0.00 AV2

+0.00 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL #

26 26 26 26 26 26 26 26 6

6 58 58 57 57 57 30 27 19 19 19 17 17 17 17 17 17 30 30 30 30 29 29 29 28 28 28 28 28 26 26 26 26 26 26 26 26 26 26 26 26 26 58 58 58 58 58 20 18 18 18 18 18 18 18 18 18 18 18 18 16 16 16 16 29 29 29 29 29 29 29 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UJL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TDL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610DL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl 12/18/12 14:59:34 Component: S/G B Page 16 of 48, Enc. 8 Page 16 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.16 0.22 0.15 0.37 0.20 86 91 0.13 0.09 86 93 0.16 86 95 0.22 0.18 0.12 0.21 86 97 0.13 0.31 0.35 0.17 86 99 0.15 0.13 0.16 0.14 0.21 0.09 86 103 0.15 0.20 0.19 86 127 0.14 86 133 0.12 87 48 0.09 87 54 0.11 87 64 0.11 0.14 87 70 0.15 0.19 0.29 0.19 87 72 0.32 0.19 87 74 0.25 0.18 87 76 0.44 0.23 87 78 0.14 0.13 0.29 87 80 0.44 0.24 87 82 0.25 0.35 0.32 0.25 0.12 87 84 0.17 0.34 0.16 87 86 0.27 0.17 0.42 0.13 0.10 87 88 0.15 0.20 0.17 0.25 87 90 0.18 0.22 0.20 87 92 0.14 0.16 0.19 87 94 0.15 0.14 87 96 0.18 0.38 0.43 0.24 0.20 87 98 0.18 0.23 87 100 0.16 0.16 DEG CHN 115 P2 105 P2 121 P2 117 P2 100 P2 133 P2 110 P2 130 P2 139 P2 117 P2 137 P2 129 P2 144 P2 130 P2 127 P2 141 P2 99 P2 133 P2 117 P2 113 P2 111 P2 60 P2 141 P2 130 P2 135 P2 94 P2 118 P2 81 P2 92 P2 123 P2 119 P2 139 P2 122 P2 125 P2 110 P2 118 P2 126 P2 107 P2 86 P2 126 P2 114 P2 99 P2 86 P2 110 P2 117 P2 111 P2 99 P2 116 P2 123 P2 123 P2 134 P2 114 P2 11 P2 137 P2 91 P2 117 P2 115 P2 125 P2 136 P2 103 P2 120 P2 105 P2 114 P2 128 P2 129 P2 113 P2 76 P2 79 P2 116 P2 134 P2 101 P2 96 P2 118 P2 117 P2 113 P2 136 P2 141 P2 124 P2 106 P2 126 P2 IND %TW TWD 6 TWD 8 TWD 6 TWD 13 TWD 8 TWD 5 TWD 4 TWD 6 TWD 8 TWD 7 TWD 5 TWD 7 TWD 5 TWD 10 TWD 12 TWD 6 TWD 6 TWD 5 TWD 6 TWD 5 TWD 8 TWD 3 TWD 6 TWD 7 TWD 7 TWD 6 TWD 5 TWD 5 TWD 6 TWD 6 TWD 7 TWD 7 TWD 9 TWD 13 TWD 9 TWD 14 TWD 9 TWD 11 TWD 8 TWD 16 TWD 10 TWD 7 TWD 6 TWD 12 TWD 16 TWD 10 TWD 11 TWD 14 TWD 13 TWD 11 TWD 6 TWD 8 TWD 14 TWD 8 TWD 10 TWD 7 TWD 14 TWD 5 TWD 4 TWD 6 TWD 8 TWD 7 TWD 9 TWD 7 TWD 8 TWD 8 TWD 6 TWD 6 TWD 8 TWD 5 TWD 5 TWD 7 TWD 12 TWD 13 TWD 9 TWD 7 TWD 7 TWD 8 TWD 6 TWD 6 LOCATION AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV7

+0.00 AV8

+0.00 AV6

-0.02 AV3

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AVI

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AVI

+0.00 AV2

+0.00 AV3

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AVI

+0.00 AV4

+0.00 AV5

+0.25 AV2

+0.05 AV4

+0.02 AV5

+0.09 AV2

+0.00 AV3

+0.05 AV5

+0.23 AV6

+0.07 AV2

+0.02 AV4

+0.07 AV5

+0.00 AV4

+0.00 AV5

+0.00 AV4

+0.00 AV6

+0.00 AV5

+0.27 AV4

+0.00 AV5

+0.00 AV4

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV2

+0.07 AV6

+0.00 AV3

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV2

+0.00 AV4

+0.00 AVI

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV8

+0.00 AV4

+0.00 AV6

+0.00 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL #

29 29 29 29 29 29 29 27 27 27 27 27 25 25 25 25 25 25 25 25 25 25 25 25 25 19 17 24 22 20 20 20 20 20 20 20 20 18 18 18 18 18 18 18 18 18 18 18 18 18 18 16 16 16 29 29 29 29 29 29 29 29 29 29 29 29 30 30 30 27 27 27 27 27 27 27 25 25 25 25 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610DL 61OUL 61OUL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 6100L 610UL 610UL 610UL 61OUL 6100L 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610TDL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:34 Component: S/G B Page 17 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect TUbes)

.QUERY:

QueryMl, Enc. 8 Page 17 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.11 87 110 0.14 87 120 0.12 87 122 0.12 88 23 0.14 88 27 0.11 88 29 0.21 88 39 0.17 88 49 0.11 88 69 0.12 88 71 0.26 88 73 0.14 0.52 88 75 0.16

0. 14 88 79 0.14 88 81 0.14 0.14 88 83 0.14 88 85 0.25 0.45 0.41 0.45 0.50 88 87 0.19 0.14 0.34
0. 32 0.15 88 89 0.21 0.18 88 91 0.16 88 93 0.11 88 95 0.22 0.19 0.23
0. 16 0.24 0.32 0.14 88 97 0.15 0.20 0.28 0.26 0.51
0. 37 88 99 0.14 0.32
0. 57 0.30 0.19 0.16 0.16 88 101 0.19 88 103 0.18 0.24 88 105 0.36 89 38 0.14 89 46 0.14 89 48 0.11 89 60 0.15 89 64 0.16 89 66 0.16 0.30 89 68 0.12 0.16 0.19 89 72 0.13 89 74 0.18 0.31 0.24 0.15 89 76 0.18 89 78 0.14 89 80 0.22 0.17 0.29 0.16 89 82 0.12 0.33 DEG CHN IND %TW LOCATION EXT EXT UTIL 1

UTIL 2

CAL # LEG 134 P2 88 P2 124 P2 134 P2 147 P2 139 P2 118 P2 125 P2 111 P2 124 P2 116 P2 132 P2 113 P2 124 P2 101 P2 133 P2 114 P2 118 P2 92 P2 136 P2 131 P2 125 P2 125 P2 117 P2 78 P2 122 P2 119 P2 115 P2 83 P2 86 P2 112 P2 123 P2 130 P2 112 P2 132 P2 119 P2 134 P2 118 P2 103 P2 129 P2 126 P2 116 P2 125 P2 125 P2 122 P2 122 P2 127 P2 117 P2 122 P2 131 P2 117 P2 138 P2 126 P2 135 P2 143 P2 121 P2 126 P2 117 P2 155 P2 101 P2 131 P2 123 P2 142 P2 128 P2 134 P2 116 P2 119 P2 120 P2 111 P2 104 P2 122 P2 126 P2 131 P2 120 P2 129 P2 136 P2 99 P2 93 P2 117 P2 116 P2 TWD 4 AV7 TWD 5 AV5 TWD 5 AV5 TWD 5 AV4 TWD 6 AV4 TWD 4 AVI TWD 9 AVI TWD 7 AV4 TWD 5 AV5 TWD 5 AV5 TWD 10 AV6 TWD 5 AV5 TWD 16 AV4 TWD 6 AV2 TWD 5 AV3 TWD 5 AV4 TWD 5 AV7 TWD 5 AV6 TWD 5 AV5 TWD 9 AV7 TWD 15 AV5 TWD 14 AV4 TWD 15 AV3 TWD 16 AV2 TWD 8 AV3 TWD 6 AV4 TWD 12 AV6 TWD 12 AV7 TWD 6 AV8 TWD 8 AV3 TWD 7 AV4 TWD 7 AV2 TWD 5 AV3 TWD 9 AV3 TWD 8 AV4 TWD 9 AV5 TWD 7 AV6 TWD 10 AV7 TWD 12 AV8 TWD 6 AV2 TWD 6 AV7 TWD 8 AV6 TWD 10 AVS TWD 10 AV4 TWD 16 AV3 TWD 13 AV2 TWD 6 AV7 TWD 12 AV6 TWD 18 AV5 TWD 11 AV4 TWD 8 AV3 TWD 6 AV2 TWD 6 AVI TWD 8 AV3 TWD 7 AV6 TWD 9 AV5 TWD 12 AV2 TWD 6 AV4 TWD 6 AV3 TWD 5 AV5 TWD 8 AV3 TWD 6 AV5 TWD 6 AV5 TWD 11 AV4 TWD 5 AV5 TWD 6 AV4 TWD 7 AV3 TWD 5 AV5 TWD 7 AV4 TWD 11 AV3 TWD 9 AV2 TWD 6 AV7 TWD 7 AV5 TWD 6 AV5 TWD 8 AV5 TWD 6 AV4 TWD 10 AV3 TWD 6 AV2 TWD 5 AV7 TWD 11 AV6

+0.00

+0.00

+0.00

+0.00

+0.14

+0.07

+0.18

+0.00

+0.23

+0.00

+0.09

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

-0.05

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.28

+0.05

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00 TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 25 23 21 21 57 57 58 27 24 19 19 17 17 17 17 17 17 17 17 41 41 41 41 41 30 30 30 30 30 30 30 30 28 28 28 28 28 28 28 28 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 27 23 23 21 19 19 19 19 19 19 19 17 17 17 17 17 17 17 17 17 17 1717 HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 610UL 610UL 610UL 610UL 610OL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610OL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610OL 610UL 610UL 610OL 610UL 610UL 610OL 610UL 610OL 610OL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610OL 610UL 610UL 610UL 610UL 610UL 610UL 610OL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610OL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:34 Component: S/G B Page 18 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes), Enc. 8 Page 18 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 QUERY: QueryMl ROW COL VOLTS 0.24 0.13 0.64 0.12 89 84 0.58 0.66 0.18 0.29 89 86 0.22 0.28 0.43 0.33 0.39 0.20 89 88 0.17 0.24 0.27 0.27 0.20 89 90 0.18 0.19 0.28 0.33 0.18 89 92 0.12 0.13 0.27 89 94 0.18 0.19 0.12 89 96 0.16 0.25 0.20 0.18 0.17 0.13 89 98 0.20 0.55 0.17 0.23 0.12 0.11 89 116 0.12 89 128 0.14 0.18 90 29 0.13 90 31 0.12 90 33 0.16 90 37 0.15 90 59 0.15 90 61 0.21 90 63 0.11 90 69 0.16 0.20 90 73 0.20 0.18 90 75 0.12 0.14 90 77 0.24 0.62 0.28 0.15 90 79 0.16 0.18 90 81 0.28 0.12 0.26 90 83 0.22 0.52 0.40 0.17 0.14 90 85 0.41 0.43 0.27 0.36 90 87 0.23 0.38 0.28 0.19 DEG 129 122 107 94 120 121 85 110 141 127 119 124 120 120 90 125 114 117 118 116 132 114 117 133 110 119 126 89 125 119 118 110 119 119 122 130 118 122 141 113 119 142 98 118 91 123 97 146 127 129 97 138 129 129 114 122 138 127 129 116 129 142 112 120 119 98 92 121 118 116 114 ill 118 122 115 123 85 117 96 122 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD TWD TWD TWD TWO TWO TWO TWD TWO TWO TWO TWD TWD TWD TWD TWO TWO TWO TWO TWO TWO TWO TWD TWD TWD TWO TWD TWD TWO TWO TWO TWO TWO TWD TWD TWO TWO TWO TWO TWO TWO TWD TWD TWD TWD TWD TWO TWO TWO TWO TWO TWD TWD TWO TWO TWO TWO TWD TWD TWD TWD TWD TWD TWO TWO TWD TWO TWO TWD TWD TWO TWO TWO TWO TWD TWO TWO TWD TWO

%TW 9

5 18 5

17 19 7

10 8

10 14 12 13 8

7 9

10 10 8

7 8

10

.12 7

5 5

10 7

7 5

6 9

7 7

6 5

7 16 6

8 5

4 5

5 7

6 5

6 6

6 8

5 6

8 8

7 5

6 9

18 10 6

6 7

10 5

9 8

16 13 6

5 13 14 10 12 9

13 10 8

LOCATION AV5 AV4 AV3 AV2 AV6 AV4 AV3 AV2 AV7 AV6 AV5 AV4 AV3 AV2 AV3 AV5 AV6 AV7 AV8 AV2 AV3 AV4 AV5 AV6 AV7 AV3 AV5 AV2 AV3 AV4 AVI AV2 AV3 AV4 AV5 AV7 AVI AV2

+

AV3 AV4 AV5 AV6

+

AV5 AV4

+

AV3 AVI AVI AV3 AV5 AV3 AV3

+

AV5

+

AV5

+

AV4

+

AV5

+

AV4

+

AV4

+

AV3

+

AV7 9

AV6 9

AV5 9

AV4 9

AV6 9

AV4 9

AV4

+

AV3 9

AV2 9

AV6

+

AV5 4

AV4 9

AV3

+

AV2

+

AV5 AV4 AV3 9

AV2 9

AV3 9

AV4 9

AV5 4

AV6

+

+0.00

+0.00

+0.00

+0.00

+0.00

+0.05

+0.07

+0.07

-0.07

-0.16

-0.07

-0.07

+0.02

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.02

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

.000 0.00 0.00 0.00 0.00

-0.14

-0.00

-0.00

-0.23

-0.21

.005

.000

.007

.007

-0.00

-0.00

-0.00

+0.00 0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00 40.00

-0.00

-0.00

-0.02

-0.07

-0.07

-0.05

  • 0.00

-0.00 0.00

-0.00 EXT EXT UTIL TEN TEC TEN TEC TEN TEC TEH TEC TEH TEC TEH TEC TEN TEC TEN TEC TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TER TEC TEN TEC TEN TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEN TEC TEH TEC TEN TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEN TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEN TEC TEN TEC TEN TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEN TEC TEH TEC TEH TEC TEH 1

UTIL 2

CAL # LEG 17 COLD 17 COLD 17 COLD 17 COLD 15 COLD 15 COLD 15 COLD 15 COLD 18 NOT 18 HOT 18 HOT 18 HOT 18 HOT 18 HOT 29 HOT 29 HOT 29 HOT 29 HOT 29 HOT 29 HOT 29 HOT 29 HOT 29 HOT 29 HOT 29 HOT 29 HOT 29 HOT 27 HOT 27 HOT 27 HOT 27 HOT 27 HOT 27 HOT 27 HOT 27 HOT 27 HOT 25 HOT 25 HOT 25 HOT 25 HOT 25 HOT 25 HOT 23 HOT 19 HOT 19 HOT 57 COLD 29 COLD 29 COLD 27 COLD 21 COLD 21 COLD 19 COLD 19 COLD 19 COLD 19 COLD 19 COLD 17 COLD 17 COLD 17 COLD 17 COLD 17 COLD 17 COLD 17 COLD 17 COLD 17 COLD 17 COLD 17 COLD 17 COLD 17 COLD 17 COLD 17 COLD 17 COLD 15 COLD 15 COLD 15 COLD 15 COLD 29 HOT 29 HOT 29 HOT 29 HOT PROBE 610UL

.61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:34 Component: S/G B Page 19 of 48 Component: S/C B Page 19 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 19 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.32 90 89 0.17 0.23 0.17 0.25 0.27 90 91 0.20 0.12 90 93 0.19 0.14 0.18 0.19 0.13 90 95 0.14 0.15 0.14 0.22 0.23 90 97 0.14 0.34 0.31 0.19 0.34 0.19 0.38 90 99 0.13 0.14 0.17 0.12 90 101 0.11 90 103 0.20 90 107 0.11 90 127 0.15 91 24 0.11 91 36 0.13 91 38 0.15 91 46 0.11 91 50 0.15 91 58 0.11 91 60 0.17 91 66 0.15 0.16 0.32 0.13 0.11 91 68 0.16 91 70 0.13 0.13 91 72 0.14 0.14 91 74 0.19 0.22 0.19 91 76 0.14 0.13 0.26 0.10 0.25 91 78 0.23 0.13 91 80 0.18 0.22 0.18 0.17 91 82 0.19 0.20 0.44 91 84 0.12 0.13 0.24 0.46 0.49 0.19 0.11 91 86 0.17 0.26 0.41 0.43 0.56 0.34 DEG CHN 118 P2 104 P2 103 P2 70 P2 127 P2 105 P2 117 P2 135 P2 121 P2 122 P2 131 P2 124 P2 108 P2 120 P2 139 P2 126 P2 126 P2 117 P2 103 P2 121 P2 124 P2 101 P2 121 P2 121 P2 108 P2 142 P2 133 P2 139 P2 103 P2 137 P2 123 P2 76 P2 99 P2 85 P2 113 P2 149 P2 140 P2 143 P2 141 P2 131 P2 145 P2 134 P2 112 P2 136 P2 110 P2 121 P2 69 P2 131 P2 123 P2 140 P2 126 P2 123 P2 136 P2 108 P2 126 P2 120 P2 111 P2 129 P2 118 P2 134 P2 141 P2 109 P2 120 P2 137 P2 128 P2 138 P2 116 P2 152 P2 111 P2 124 P2 120 P2 106 P2 141 P2 95 P2 58 P2 104 P2 107 P2 114 P2 102 P2 93 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW 1i 7

9 7

9 10 8

5 7

5 7

7 5

5 5

5 8

8 5

11 10 7

11 7

12 5

5 6

4 4

7 4

6 5

5 6

5 6

5 7

6 7

12 6

5 7

6 6

6 6

8 9

8 6

6 10 5

10 9

6 7

9 8

7 8

8 15 5

6 10 16 16 8

5 7

10 14 14 17 12 LOCATION AV7

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV2

+0.00 AV3

+0.00 AV2

+0.00 AV3

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AVS

+0.00 AV6

+0.00 AVI

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV6

+0.00 AV7

+0.00 AV8

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV7

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV5

+0.00 AVI

-0.61 AV4

+0.00 AV5

+0.00 AV5

+0.00 AV6

+0.21 AV4

+0.00 AV4

+0.02 AV6

+0.00 AV5

+0.00 AV4

+0.00 AVI

+0.00 AV7

-0.09 AV3

+0.07 AV5

+0.25 AV4

+0.00 AV5

+0.12 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AVI

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV7

+0.00 AV3

+0.00 AV5

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV2

+0.00 AV4

+0.00 AV5

+0.00 AVI

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL #

29 29 29 29 29 29 29 29 27 27 27 27 27 27 27 27 27 27 25 25 25 25 25 25 25 25 25 25 25 25 25 23 19 57 13 13 11 11 10 10 8

8 8

8 8

8 8

8 8

8 8

8 8

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 15 15 15 15 15 15 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT PROBE 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 61OUL 610UL 610UL 61OUL 610UL 610OL 610UL 610UL 61OUL 61OUL 61OUL 610UL 61OUL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 6100L 610UL 610UL 61OUL 610UL 610UL 610UL 610OL 6100L 610UL 610UL 610OL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:34 Component: S/G B Page 20 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 20 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 91 88 0.16 0.21 0.17 0.26 0.12 91 90 0.26 0.13 0.21 0.22 0.15 91 92 0.11 0.11 0.21 0.16 0.14 0.18 91 94 0.15 0.18 91 96 0.17 0.14 0.17 0.15 91 98 0.22 0.12 0.15 0.19 0.19 0.25 91 100 0.1'3 91 120 0.18 91 122 0.15 0.15 91 124 0.15 91 128 0.15 91 130 0.12 0.14 92 37 0.13 92 39 0.14 92 49 0.14 92 65 0.15 92 69 0.14 0.18 92 73 0.14 92 75 0.13 0.17 92 77 0.15 0.25 0.23 0.25 0.37 92 79 0.23 0.35 0.26 92 81 0.24 0.31 0.30 0.13 92 83 0.16 0.45 0.30 0.12 92 85 0.10 0.27 0.13 0.22 0.49 0.55 92 87 0.23 0.32 0.32 0.29 0.38 0.21 92 89 0.21 0.17 92 91 0.19 0.23 92 93 0.13 0.18 0.28 DEG CHN 80 P2 95 P2 129 P2 110 P2 74 P2 117 P2 75 P2 89 P2 112 P2 62 P2 136 P2 93 P2 126 P2 126 P2 98 P2 96 P2 90 P2 112 P2 96 P2 118 P2 115 P2 104 P2 119 P2 110 P2 90 P2 118 P2 110 P2 103 P2 88 P2 118 P2 108 P2 83 P2 130 P2 103 P2 103 P2 109 P2 119 P2 92 P2 129 P2 137 P2 141 P2 125 P2 141 P2 88 P2 87 P2 137 P2 138 P2 124 P2 121 P2 128 P2 128 P2 126 P2 132 P2 119 P2 120 P2 121 P2 108 P2 104 P2 128 P2 121 P2 136 P2 130 P2 122 P2 132 P2 129 P2 122 P2 115 P2 88 P2 113 P2 97 P2 103 P2 97 P2 112 P2 101 P2 61 P2 110 P2 73 P2 131 P2 1.13 P2 110 P2 IND %TW LOCATION TWD 6 AV8

+0.00 TWD 8 AV7

+0.00 TWD 7 AV6

+0.00 TWD 9 AV5

+0.00 TWD 5 AV3

+0.00 TWD 10 AV7

+0.00 TWD 5 AV6

+0.00 TWD 8 AV5

+0.00 TWD 8 AV4

+0.00 TWD 6 AV3

+0.00 TWD 4 AV3

+0.00 TWD 4 AV4

+0.00 TWD 8 AV5

+0.00 TWD 6 AV6

+0.00 TWD 6 AV7

-0.28 TWD 7 AV8

+0.00 TWD 6 AV2

+0.00 TWD 7 AV3

+0.00 TWD 7 AVl

+0.00 TWD 6 AV2

+0.00 TWD 7 AV3

+0.00 TWD 6 AV7

+0.00 TWD 9 AVi

+0.00 TWD 5 AV2

+0.00 TWD 6 AV4

+0.00 TWD 8 AV5

+0.00 TWD 7 AV6

+0.00 TWD 9 AV7

+0.00 TWD 5 AV4

+0.00 TWD 7 AV5

-0.07 TWD 6 AV5

+0.00 TWD 6 AV3

+0.12 TWD 6 AV4

+0.00 TWD 6 AV4

-0.05 TWD 5 AV5

+0.07 TWD 5 AV4

-0.05 TWD 5 AV5

+0.05 TWD 6 AV5

+0.02 TWD 6 AV4

+0.00 TWD 6 AV4

+0.00 TWD 6 AV6

+0.00 TWD 8 AV3

+0.00 TWD 6 AV4

+0.00 TWD 5 AV3

+0.00 TWD 7 AV8

+0.00 TWD 6 AV2

+0.00 TWD 10 AV4

+0.00 TWD 9 AV5

+0.00 TWD 10 AV6

+0.00 TWD 13 AV7

+0.00 TWD 9 AV4

+0.00 TWD 13 AV5

+0.00 TWD 10 AV6

+0.00 TWD 9 AV3

+0.00 TWD 12 AV6

+0.00 TWD 11 AV7

+0.00 TWD 5 AV8

+0.00 TWD 7 AV2

+0.00 TWD 15 AV3

+0.00 TWD 11 AV4

+0.00 TWD 5 AV6

+0.00 TWD 5 AVI

+0.00 TWD 11 AV2

+0.00 TWD 6 AV3

+0.00 TWD 9 AV4

+0.00 TWD 17 AV5

+0.05 TWD 18 AV7

+0.00 TWD 9 AV8

+0.00 TWD 11 AV7

+0.00 TWD 11 AV6

+0.00 TWD 10 AV4

+0.00 TWD 13 AV3

+0.00 TWD 8 AVI

+0.00 TWD 8 AV4

+0.00 TWD 7 AV3

+0.00 TWD 7 AV6

+0.00 TWD 9 AV3

+0.00 TWD 5 AV4

+0.00 TWD 7 AV5

+0.00 TWD 11 AV6

+0.00 EXT TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC EXT TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH UTIL 1

UTIL 2

CAL # LEG 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 NOT 13 HOT 13 HOT 13 HOT 13 HOT 10 HOT 10 HOT 10 HOT 10 HOT 10 HOT 10 HOT 10 HOT 13 COLD 13 COLD 11 COLD 8

COLD 8

COLD 8

COLD 8

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 4

COLD 4

COLD 4

COLD 4

COLD 4

COLD 4

COLD 15 HOT 15 HOT 15 NOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 13 HOT 13 HOT 13 NOT PROBE 610UL 610UL 6100L 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610DL 61OUL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610OL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:34 Component: S/G B Page 21 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 21 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.10 92 95 0.17 0.23 0.36 0.23 92 97 0.11 0.14 0.11 0.14 92 99 0.27 0.25 0.09 0.15 0.37 0.12 0.12 0.19 92 101 0.27 0.17 92 103 0*18 92 107 0.18 92 117 0.15 92 123 0.18 92 125 0.13 93 24 0.14 93 30 0.12 93 40 0.12 0.12 93 44 0.13 93 46 0.12 93 72 0.34 0.21 93 74 0.12 0.25 0.16 93 76 0.20 93 78 0.25 0.20 93 80 0.15 0.19 0.27 0.14 93 82 0.14 0.51

0. 37 0.18 0.13 93 84 0.26 0.33 0.53 0.45 0.34 0.22 93 86 0.56 0.52 0.62 0.47 0.18 93 88 0.16 0.34 0.39 0.13 0.27 0.28 93 90 0.18 0.21 0.12 0.17 93 92 0.12
0. 32 0.16 0.16 0.23 0.16 93 94 0.33 0.52 0.17 0.49 0.25 0.20 DEG CHN 84 P2 125 P2 105 P2 122 P2 111 P2 109 P2 90 P2 112 P2 105 P2 131 P2 114 P2 61 P2 129 P2 119 P2 99 P2 125 P2 112 P2 102 P2 132 P2 133 P2 125 P2 103 P2 105 P2 82 P2 100 P2 99 P2 143 P2 86 P2 133 P2 117 P2 117 P2 101 P2 103 P2 107 P2 116 P2 107 P2 104 P2 89 P2 135 P2 113 P2 99 P2 94 P2 103 P2 120 P2 103 P2 125 P2 82 P2 129 P2 124 P2 124 P2 128 P2 120 P2 120 P2 109 P2 112 P2 119 P2 99 P2 90 P2 112 P2 I11 P2 119 P2 120 P2 117 P2 89 P2 111 P2 129 P2 111 P2 100 P2 124 P2 135 P2 121 P2 125 P2 130 P2 127 P2 125 P2 129 P2 136 P2 126 P2 131 P2 122 P2 IND %TW TWD 4 TWD 7 TWD 9 TWD 13 TWD 9 TWD 5 TWD 6 TWD 4 TWD 6 TWD 10 TWD 9 TWD 4 TWD 6 TWD 13 TWD 5 TWD 5 TWD 8 TWD 10 TWD 7 TWD 7 TWD 7 TWD 6 TWD 7 TWD 5 TWD 6 TWD 5 TWD 6 TWD 6 TWD 5 TWD 5 TWD 15 TWD 11 TWD 6 TWD 12 TWD 8 TWD 10 TWD 12 TWD 10 TWD 8 TWD 9 TWD 13 TWD 7 TWD 7 TWD 19 TWD 16 TWD 9 TWD 7 TWD 10 TWD 12 TWD 17 TWD 15 TWD 13 TWD 9 TWD 17 TWD 16 TWD 18 TWD 15 TWD 7 TWD 6 TWD 12 TWD 13 TWD 5 TWD 10 TWD 10 TWD 7 TWD 8 TWD 5 TWD 6 TWD 5 TWD 11 TWD 6 TWD 6 TWD 8 TWD 6 TWD 11 TWD 16 TWD 6 TWD 15 TWD 9 TWD 7 LOCATION EXT EXT AV7

+0.00 TEC TEH AV2

+0.00 TEC TEH AV3

+0.00 TEC TEH AV5

+0.00 TEC TEH AV6

+0.00 TEC TEH AV2

+0.00 TEC TEH AV3

+0.00 TEC TEH AV4

+0.00 TEC TEH AV7

+0.00 TEC TEH AVI

+0.00 TEC TEH AV2

+0.00 TEC TEH AV3

+0.00 TEC TEH AV4

+0.00 TEC TEH AV5

+0.00 TEC TEH AV6

+0.00 TEC TEH AV7

+0.00 TEC TEH AV8

+0.00 TEC TEH AV2

+0.00 TEC TEH AV5

+0.00 TEC TEH AV4

+0.00 TEC TEH AV4

+0.00 TEC TEH AV4

+0.07 TEC TEH AV5

+0.00 TEC TEH AV4

+0.00 TEC TEH AVI

-0.16 TEH TEC AVI

+0.18 TEH TEC AV4

+0.00 TEH TEC AV3

+0.00 TEH TEC AV4

-0.07 TEH TEC AV4

+0.00 TEH TEC AV5

+0.05 TEH TEC AV6

+0.05 TEH TEC AV2

+0.05 TEH TEC AV4

+0.09 TEH TEC AV5

+0.09 TEH TEC AV6

+0.00 TEH TEC AV5

+0.00 TEH TEC AV6

+0.00 TEH TEC AV3

+0.00 TEH TEC AV5

+0.00 TEH TEC AV6

+0.00 TEH TEC AV7

+0.00 TEH TEC AV4

+0.00 TEH TEC AV5

+0.00 TEH TEC AV6

+0.00 TEH TEC AV2

+0.00 TEH TEC AV3

+0.00 TEH TEC AV2

+0.00 TEH TEC AV3

+0.00 TEH TEC AV5

+0.00 TEH TEC AV6

+0.00 TEH TEC AV7

+0.00 TEH TEC AV8

+0.00 TEH TEC AV7

+0.00 TEC TEH AV6

+0.00 TEC TEH AV5

+0.00 TEC TEH AV3

+0.00 TEC TEH AV2

+0.00 TEC TEH AV7

+0.00 TEC TEH AV6

+0.00 TEC TEH AV5

+0.00 TEC TEH AV4

+0.00 TEC TEH AV3

+0.00 TEC TEH AV2

+0.00 TEC TEH AV7

+0.00 TEC TEH AV5

+0.00 TEC TEH AV4

+0.00 TEC TEH AV2

+0.00 TEC TEH AV6

+0.00 TEC TEH AV5

-0.02 TEC TEH AV4

-0.12 TEC TEH AV3

+0.02 TEC TEH AV2

+0.05 TEC TEH AV8

-0.09 TEC TEH AV6

+0.00 TEC TEH AV5

+0.02 TEC TEH AV4

+0.05 TEC TEH AV3

+0.02 TEC TEH AV2

+0.09 TEC TEH AVI

-0.02 TEC TEH UTIL 1

UTIL 2

CAL #

13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 11 11 10 10 58 57 14 14 13 11 9

9 9

9 9

7 7

7 7

7 7

7 7

7 7

7 7

6 6

6 6

6 6

16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT NOT NOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT NOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 6100L 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:34 Component: S/G B Page 22 of 48 Component: S/U B Page 22 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 22 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.23 93 96 0.16 0.18 93 98 0.16 0.70 0.15 0.16 0.23 0.39 0.19 0.13 93 100 0.26 0.28 0.19 93 102 0.21 0.24 93 104 0.18 0.15 93 106 0.18 93 112 0.15 94 25 0.11 94 31 0.11 94 39 0.14 94 41 0.12 94 45 0.18 94 47 0.17 0.12 94 49 0.11 94 55 0.11 0.16 94 67 0.35 94 69 0.41 0.40 94 71 0.10 94 73 0.28 0.18 0.23 0.09 94 75 0.13 0.11 94 77 0.18 0.24 0.24 94 79 0.20 0.16 0.18 94 81 0.26 0.32 0.48 94 83 0.17 0.21 0.16 0.20 94 85 0.26 0.61 0.47 0.24 0.33 94 87 0.26 0.38 0.48 0.45 0.28 0.18 94 89 0.12 0.15 0.25 0.22 0.20 0.14 94 91 0.16 0.37 94 93 0.10 0.11 0.23 94 95 0.27 94 97 0.28 94 99 0.11 0.15 0.14 DEG CHN 113 P2 99 P2 124 P2 107 P2 120 P2 140 P2 134 P2 122 P2 114 P2 127 P2 135 P2 120 P2 126 P2 138 P2 136 P2 131 P2 105 P2 123 P2 124 P2 104 P2 112 P2 134 P2 103 P2 134 P2 127 P2 108 P2 115 P2 117 P2 115 P2 144 P2 121 P2 108 P2 112 P2 123 P2 121 P2 100 P2 85 P2 122 P2 98 P2 81 P2 106 P2 99 P2 87 P2 83 P2 113 P2 90 P2 87 P2 112 P2 105 P2 116 P2 79 P2 140 P2 99 P2 82 P2 93 P2 97 P2 62 P2 80 P2 83 P2 107 P2 114 P2 100 P2 80 P2 70 P2 133 P2 118 P2 105 P2 107 P2 83 P2 111 P2 101 P2 117 P2 73 P2 109 P2 97 P2 115 P2 110 P2 105 P2 96 P2 130 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW 8

6 7

6 19 6

6 8

13 7

5 9

10 7

8 9

7 6

7 6

5 5

7 5

8 7

5 5

5 7

15 17 17 6

13 9

11 5

7 6

9 11 11 10 8

9 12 14 19 9

10 8

10 10 19 16 9

12 9

13 15 15 10 7

5 6

9 8

8 5

6 13 4

5 9

10 11 5

6 6

LOCATION AV7 AV4 AV3 AV8 AV7 AV6 AV5 AV4 AV3 AV2 AVl AV7 AV4 AV2 AV5 AV4 AV4 AV3 AV4 AV4 AVI AVI AV5 AV4 AV4 AV2 AV5 AV4 AV4 AVS AV4 AV3 AV4 AV5 AVI AV2 AV4 AV5 AV3 AV4 AV4 AV5 AV6 AV2 AV3 AV6 AV3 AV5 AV6 AV2 AV6 AV7 AV8 AVl AV3 AV5 AV6 AV7 AV7 AV6 AV5 AV4 AV3 AV2 AV7 AV5 AV4 AV3 AV2 AVl AV7 AV6 AV2 AV3 AV4 AV5 AV2 AV2 AV3 AV4

-0.02

-0.09

-0.25

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

-0.09

-0.09

+0.00

+0.21

+0.00

+0.05

+0.05

+0.16

+0.02

+0.00

+0.00

+0.05

+0.09

+0.14

+0.02

-0.09

+0.00

+0.12

+0.12

-0.12

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.05

+0.07

+0.05

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 12 12 12 12 58 57 14 13 58 58 58 57 57 57 9

9 9

9 9

9 9

9 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

5 5

5 5

5 15 15 15 15 15 15 16 16 16 16 16 16 15 15 13 13 13 13 13 13 13 13

  1. LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 6100L 610OL 610UL 610OUL 610UL 610OUL 61OUL 610UL 610OUL 610OUL 610UL 610UL 610OUL 610OUL 610OUL 610UL 610UL 610OUL 610UL 6100L 6100L 6100L 610UL 610UL 61OUL 610UL 610OUL 610OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 6100L 610UL 6100L 610UL 610UL 610UL 610UL 610UL 6100L 610UL 610UL 6100L 610UL 610UL 610UL 610UL 610UL 610UL 610UL 6100L 610UL 6100L 610OL 6100L 610OL 6100L 610UL 610UL 6100L 610OL 6100L 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:34 Component: S/G B Page 23 of 48 Component: S/S B Page 23 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY:

QueryMl, Enc. 8 Page 23 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.16 0.24 0.11 94 101 0.10 0.19 94 105 0.19 94 119 0.15 94 123 0.11 95 28 0.14 95 46 0.18 95 48 0.17 95 50 0.11 0.10 95 54 0.11 95 58 0.13 95 62 0.13 95 66 0.25 95 68 0.12 95 70 0.26 0.14 95 72 0.13 0.20 95 74 0.13 95 76 0.17 95 78 0.30 0.13 95 80 0.41 0.38 0.18 0.24 95 82 0.17 0.15 0.12 0.23 0.11 95 84 0.13 0.40 0.24 0.26 95 86 0.55 0.45 0.64 0.51 95 88 0.16 0.44 0.51 0.25 0.19 0.35 95 90 0.17 0.18 0.27 95 92 0.15 0.10 0.15 95 94 0.27 0.50 0.26 0.22 0.27 0.21 0.10 95 96 0.14 0.25 0.34 0.22 95 98 0.10 0.08 0.16 0.50 0.13 95 100 0.14 0.27 0.47 0.48 0.36 0.12 95 102 0.14 95 120 0.16 0.13 DEG CHN 127 P2 117 P2 59 P2 66 P2 126 P2 86 P2 66 P2 132 P2 90 P2 114 P2 131 P2 134 P2 85 P2 158 P2 133 P2 88 P2 114 P2 88 P2 112 P2 101 P2 150 P2 122 P2 120 P2 130 P2 134 P2 134 P2 116 P2 118 P2 129 P2 125 P2 81 P2 102 P2 133 P2 129 P2 130 P2 120 P2 11 P2 108 P2 109 P2 111 P2 107 P2 103 P2 105 P2 130 P2 104 P2 107 P2 117 P2 100 P2 111 P2 82 P2 70 P2 117 P2 110 P2 104 P2 110 P2 107 P2 116 P2 99 P2 126 P2 126 P2 119 P2 113 P2 98 P2 85 P2 119 P2 114 P2 118 P2 125 P2 127 P2 119 P2 130 P2 98 P2 109 P2 111 P2 106 P2 117 P2 117 P2 108 P2 79 P2 111 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW 7

9 4

4 7

7 6

5 6

8 7

5 4

5 5

5 10 6

12 8

6 8

6 7

11 5

14 14 7

10 7

6 5

9 5

7 17 11 12 17 15 19 16 6

14 16 9

7 12 7

7 10 6

4 6

10 16 10 9

10 8

4 6

9 12 8

4 3

6 16 5

6 10 15 16 13 5

6 6

5 LOCATION AV5

+0.00 AV6

+0.00 AV7

+0.00 AV3

+0.00 AV4

+0.00 AV2

+0.00 AV5

+0.00 AV4

+0.00 AVI

-0.09 AV4

+0.16 AV5

+0.09 AV4

+0.00 AV5

+0.00 AV3

+0.07 AV4

+0.00 AV5

+0.00 AV4

+0.09 AV3

-0.09 AV4

+0.05 AV6

+0.09 AV5

+0.00 AV3

+0.00 AV3

+0.12 AV5

+0.00 AV3

+0.00 AV5

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV7

+0.00 AVI

+0.00 AV2

+0.00 AV6

+0.00 AV8

+0.00 AV7

+0.00 AV6

+0.00 AV3

+0.00 AV2

+0.00 AV8

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV3

+0.00 AV2

+0.00 AV4

+0.00 AV6

+0.00 AV5

+0.00 AV2

+0.00 AV4

-0.23 AV5

+0.12 AVI

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV5

+0.00 AV6

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AVI

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV4

+0.00 AVS

-0.05 AV4

-0.12 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL #

13 13 13 13 13 11 10 9

58 58 57 11 11 57 10 10 8

9 9

9 8

8 8

6 6

6 6

6 6

6 6

6 6

6 6

7 7

7 7

15 15 15 15 15 15 15 15 15 15 15 15 15 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 10 10 LEG HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 6100L 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UDL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UDL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:34 Component: S/G B Page 24 of 48 Component: 5/0 B Page 24 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 24 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 95 122 0.12 95 124 0.15 96 39 0.15 96 41 0.15 96 43 0.11 96 47 0.11 96 57 0.18 96 59 0.27 96 61 0.11 96 67 0.14 96 69 0.17 96 71 0.18 0.15 96 73 0.34 0.20 96 75 0.15 0.13 0.10 96 77 0.18 0.40 0.29 96 79 0.13 0.33 0.15 0.31 0.11 96 81 0.18 0.26 0.17 0.12 0.15 96 83 0.29 0.34 0.57 0.46 0.15 0.31 0.25 96 85 0.15 0.41 0.22 96 87 0.19 0.38 0.37 0.47 0.43 0.33 96 89 0.14 0.28 0.44 0.30 0.18 96 91 0.14 0.17 0.17 0.16 96 93 0.16 0.17 0.15 0.19 0.24 0.36 0.30 96 95 0.18 0.31

0. 32 0.15 0.21 0.20 96 97 0.41 0.23
0. 22 0.45 0.24 96 99 0.22 96 101 0.15 0.20 0.14 96 103 0.15 0.40 DEG CHN 66 P2 70 P2 140 P2 145 P2 135 P2 144 P2 139 P2 127 P2 134 P2 90 P2 122 P2 118 P2 122 P2 125 P2 142 P2 117 P2 147 P2 128 P2 144 P2 131 P2 107 P2 111 P2 128 P2 122 P2 134 P2 116 P2 140 P2 112 P2 129 P2 153 P2 139 P2 118 P2 92 P2 111 P2 117 P2 140 P2 128 P2 113 P2 131 P2 120 P2 104 P2 129 P2 110 P2 109 P2 117 P2 104 P2 103 P2 108 P2 95 P2 104 P2 93 P2 72 P2 79 P2 115 P2 80 P2 96 P2 120 P2 126 P2 142 P2 134 P2 113 P2 130 P2 128 P2 123 P2 121 P2 127 P2 93 P2 132 P2 132 P2 136 P2 133 P2 136 P2 118 P2 119 P2 123 P2 135 P2 111 P2 115 P2 138 P2 133 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW 5

6 6

6 5

5 7

10 5

6 7

8 6

13 8

6 6

5 7

14 11 5

12 6

12 5

7 10 7

5 6

11 12 18 16 6

12 10 7

15 9

7 13 12 15 14 11 6

10 14 11 7

5 6

7 6

6 6

6 7

9 12 10 7

11 11 6

8 7

13 8

8 14 9

8 6

7 5

6 13 LOCATION AV5

+0.00 AV4

+0.00 AV4

+0.00 AV5

+0.07 AV4

+0.02 AV3

+0.07 AV4

+0.02 AV4

+0.09 AVI

+0.02 AV4

+0.00 AV5

+0.09 AV7

+0.00 AV6

+0.00 AV4

+0.00 AV5

+0.00 AV3

+0.00 AV4

+0.00 AV7

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV3

+0.00 AV4

+0.00 AVS

+0.00 AV6

+0.00 AV7

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV8

+0.00 AVI

+0.00 AV2

+0.00 AV3

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV8

+0.00 AVl

+0.00 AV5

+0.12 AV8

+0.00 AV8

+0.00 AV7

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV8

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV8

-0.05 AV7

-0.05 AV6

-0.16 AV5

+0.00 AV4

-0.11 AV3

-0.02 AV2

-0.32 AV8

-0.09 AV6

-0.05 AV5

-0.02 AV4

-0.09 AV3

+0.02 AV2

-0.44 AV6

-0.05 AV5

-0.07 AV4

-0.07 AV3

-0.07 AV2

-0.16 AV4

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV5

+0.00 AV4

+0.00 EXT EXT TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL #

10 10 13 13 13 11 10 10 10 8

8 8

8 8

8 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

4 4

4 16 16 16 16 16 16 15 15 15 15 15 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 LEG HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 6100L 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 6100L 610UL 610UL 6100L 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:34 Component: S/G B Page 25 of 48 Component: S/C B Page 25 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 25 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 96 105 0.39 0.31 96 107 0.15 96 109 0.12 0.15 96 117 0.12 97 34 0.15 97 44 0.14 97 48 0.16 97 50 0.22 97 54 0.15 97 58 0.32 0.15 97 68 0.26 0.13 97 70 0.18 0.16 0.13 0.12 97 76 0.20 0.27 0.14 97 78 0.15 97 80 0.13 97 82 0.18

0. 14 0.17 0.19 0.31 0.13 97 84 0.42
0. 37 0.51 0.33 97 86 0.22 0.55 0.37 97 88 0.12 0.32 0.24 0.24 0.15 0.13 97 90 0.15 0.20 0.13 0.16 0.43 0.15 0.11 97 92 0.24 0.17 0.13 0.24 0.45 0.30 0.25 97 94 0.27 0.29 0.16 0.23 0.22 0.17 0.18 97 96 0.23 0.26 0.24 0.18 0.15 0.20 97 98 0.22 0.22 0.53 0.30 0.31 0.16 97 100 0.28 0.41 0.19 97 102 0.12 DEG 122 125 120 125 95 115 138 131 140 120 139 124 137 132 135 140 116 135 129 86 104 110 132 96 93 101 113 115 97 102 117 108 119 121 116 115 109 74 118 104 98 82 80 83 110 90 87 120 115 105 117 87 88 129 128 129 109 127 133 129 131 114 119 136 129 127 123 125 114 139 119 122 123 131 131 146 128 133 128 142 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWD 13 TWD 11 TWD 6 TWD 5 TWD 6 TWD 5 TWD 6 TWD 6 TWD 6 TWD 9 TWD 6 TWD 12 TWD 6 TWD 10 TWD 6 TWD 8 TWD 7 TWD 6 TWD 5 TWD 10 TWD 12 TWD 7 TWD 8 TWD 7 TWD 9 TWD 7 TWD 8 TWD 9 TWD 14 TWD 7 TWD 15 TWD 13 TWD 17 TWD 12 TWD 8 TWD 16 TWD 12 TWD 5 TWD 11 TWD 9 TWD 9 TWD 6 TWD 5 TWD 6 TWD 8 TWD 5 TWD 6 TWD 14 TWD 6 TWD 5 TWD 9 TWD 6 TWD 5 TWD 9 TWD 14 TWD 10 TWD 9 TWD 10 TWD 10 TWD 6 TWD 8 TWD 8 TWD 6 TWD 7 TWD 8 TWD 9 TWD 9 TWD 7 TWD 6 TWD 7 TWD 8 TWD 8 TWD 16 TWD 10 TWD 11 TWD 6 TWD 10 TWD 13 TWD 7 TWD 5 LOCATION AV3

+0.05 AV2

-0.23 AV3

+0.00 AV7

+0.00 AV5

+0.00 AV3

+0.00 AV3

+0.00 AV4

+0.00 AVS

+0.09 AV4

+0.05 AV3

+0.09 AV5

+0.02 AV4

+0.02 AV5

+0.00 AV3

+0.00 AV5

+0.07 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV6

+0.00 AV5

+0.00 AV3

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV7

+0.00 AV8

+0.00 AV6

+0.00 AV2

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AVI

+0.00 AV8

-0.09 AV7

-0.05 AV6

+0.00 AV5

-0.02 AV4

-0.09 AV3

-0.21 AV2

-0.23 AV7

-0.05 AV6

-0.09 AVS

+0.00 AV4

-0.07 AV3

+0.12 AV2

-0.14 AVl

+0.02 AV6

-0.09 AV5

-0.07 AV4

-0.11 AV3

+0.11 AV2

+0.00 AVI

-0.21 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV4

-0.14 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL #

12 12 12 12 12 12 13 13 11 58 11 10 10 8

8 8

8 8

8 7

7 7

7 7

7 7

7 7

7 7

6 6

6 6

16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 LEG HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UDL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:34 Component: S/G B Page 26 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 26 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.14 97 104 0.28 0.22 97 114 0.11 97 118 0.17 0.13 98 27 0.15 98 29 0.13 98 49 0.11 98 51 0.16 98 53 0.13 0.12 98 57 0.17 98 67 0.14 98 69 0.18 0.13 98 71 0.11 98 77 0.16 0.20 98 79 0.16 98

-81 0.30 0.37 0.16 98 83 0.13 0.13 0.19 0.43 0.50 98 85 0.21 0.31 0.38 0.18 98 87 0.36 0.52 0.41 0.22 98 89 0.21 0.21 0.25 0.13 98 91 0.30 98 93 0.41 0.12 0.12 98 95 0.12 0.18 0.16 98 97 0.54 0.20 98 99 0.12 0.11 0.24 98 101 0.10 0.10 98 103 0.22 0.19 0.35 0.19 98 105 0.20 98 109 0.19 98 11 0.18 98 121 0.15 99 32 0.11 99 42 0.14 99 44 0.11 99 46 0.15 99 48 0.14 0.13 99 50 0.15 0.12 99 52 0.12 0.14 99 54 0.16 99 66 0.38 0.32 99 68 0.21 0.23 0.18 99 72 0.15 0.22 DEG CHN 117 P2 120 P2 110 P2 138 P2 118 P2 122 P2 134 P2 152 P2 135 P2 133 P2 151 P2 114 P2 148 P2 92 P2 105 P2 104 P2 120 P2 98 P2 102 P2 92 P2 84 P2 118 P2 109 P2 117 P2 123 P2 111 P2 95 P2 113 P2 104 P2 93 P2 92 P2 50 P2 90 P2 112 P2 100 P2 95 P2 96 P2 116 P2 111 P2 107 P2 85 P2 119 P2 111 P2 106 P2 148 P2 111 P2 122 P2 117 P2 133 P2 146 P2 114 P2 109 P2 93 P2 142 P2 133 P2 112 P2 110 P2 124 P2 112 P2 128 P2 108 P2 123 P2 66 P2 138 P2 130 P2 144 P2 135 P2 144 P2 147 P2 136 P2 130 P2 130 P2 143 P2 126 P2 136 P2 121 P2 92 P2 94 P2 140 P2 115 P2 IND %TW TWD 5 TWD 10 TWD 8 TWD 5 TWD 6 TWD 5 TWD 6 TWD 6 TWD 5 TWD 7 TWD 6 TWD 5 TWD 7 TWD 7 TWD 9 TWD 7 TWD 6 TWD 8 TWD 10 TWD 8 TWD 13 TWD 16 TWD 8 TWD 7 TWD 7 TWD 9 TWD 17 TWD 19 TWD 9 TWD 12 TWD 14 TWD 7 TWD 12 TWD 16 TWD 14 TWD 8 TWD 8 TWD 8 TWD 9 TWD 5 TWD 11 TWD 14 TWD 5 TWD 5 TWD 5 TWD 7 TWD 7 TWD 17 TWD 8 TWD 5 TWD 4 TWD 9 TWD 4 TWD 4 TWD 9 TWD 7 TWD 12 TWD 8 TWD 7 TWD 7 TWD 7 TWD 6 TWD 5 TWD 6 TWD 5 TWD 6 TWD 6 TWD 5 TWD 6 TWD 5 TWD 5 TWD 6 TWD 6 TWD 14 TWD 12 TWD 11 TWD 11 TWD 9 TWD 6 TWD 9 LOCATION AVI AV4 AV3 AV4 AV5 AV4 AVI AV2 AV5 AV4 AV3 AV6 AV4 AVI AV2 AV4 AV3 AV4 AV5 AV6 AV3 AV4 AV5 AV6 AV7 AV2 AV3 AV4 AVI AV5 AV6 AV8 AV8 AV5 AV4 AV3 AV6 AV5 AV4 AV3 AV3 AV4 AV2 AV3 AV2 AV7 AV8 AV2 AV4 AV2 AV3 AV4 AV3 AV7 AV2 AV3 AV4 AV5 AV3 AV3 AV5 AV3 AVI AV3 AV4 AV5

.+

AV3 AV5 AV4 AV2 AV3 AV4 1

AV6 1

AV5 1

AV4

+

AV2

+

AV3

+

AV4 1

AV6 1

AV5 1

+0.00

+0.00

+0.00

-0.11

-0.02

-0.12

-0.19

+0.00

+0.18

+0.02

+0.02

+0.27

+0.05

+0.07

+0.07

-0.09

-0.12

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.07

+0.14

+0.07

+0.07

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

-0.21

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.05

+0.09

+0.23

+0.00

-0.12 0.00

+0.07

  • 0.11

+0.00

+0.00

+0.09 r0.07

+0.09 r0.00

+0.00 r0.09 r0.09 r0.12

+0.00 r0.00 EXT EXT

==------TEC TEN-TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC UTIL 1

UTIL 2

CAL # LEG 14 HOT 12 HOT 12 HOT 12 HOT 10 HOT 10 HOT 58 COLD 57 COLD 57 COLD 58 COLD 57 COLD 57 COLD 10 COLD 9

COLD 9

COLD 9

COLD 9

COLD 7

COLD 7

COLD 7

COLD 7

COLD 7

COLD 7

COLD 7

COLD 7

COLD 7

COLD 7

COLD 7

COLD 5

COLD 5

COLD 5

COLD 5

COLD 15 HOT 15 HOT 15 HOT 15 HOT 16 HOT 16 HOT 16 HOT 16 HOT 15 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 11 HOT 11 HOT 12 HOT 10 HOT 57 COLD 13 COLD 13 COLD 58 COLD 57 COLD 57 COLD 11 COLD 11 COLD 57 COLD 57 COLD 57 COLD 8

COLD 8

COLD 9

COLD 9

COLD 9

COLD 8

COLD 8

COLD PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610DUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 610UL 610UL 610DL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UDL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:34 Component: S/G B Page 27 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 27 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 99 76 0.40 0.13 0.16 0.18 0.11 99 78 0.18 0.19 0.15 0.13 99 80 0.32 0.23 0.16 99 82 0.33 0.27 0.12 0.15 0.14 99 84 0.13 0.48 0.43 0.15 0.16 99 86 0.16 0.25 0.47 0.34 99 88 0.14 0.42 0.37 0.22 0.17 0.15 99 90 0.15 0.21 0.12 0.14 0.21 0.12 99 92 0.15 0.40 0.22 0.58 0.35 99 94 0.12 0.25 0.30 0.25 0.16 0.15 99 96 0.33 0.36 0.12 0.18 99 98 0.45 0.18 99 100 0.17 99 102 0.17 0.16 99 104 0.13 0.27 99 108 0.29 0.25 99 110 0.29 99 120 0.13 100 31 0.14 0.17 100 45 0.12 100 47 0.12 100 65 0.17 0.41 100 71 0.18 0.13 0.18 100 75 0.12 0.11 100 77 0.14 0.13 0.48 0.34 0.19 DEG CHN IND 118 P2 TWD 128 P2 TWD 132 P2 TWD 113 P2 TWD 128 P2 TWD 116 P2 TWD 121 P2 TWD 114 P2 TWD 133 P2 TWD 124 P2 TWD 133 P2 TWD 137 P2 TWD 125 P2 TWD 128 P2 TWD 137 P2 TWD 113 P2 TWD 133 P2 TWD 100 P2 TWD 114 P2 TWD 98 P2 TWD 76 P2 TWD 73 P2 TWD 104 P2 TWD 103 P2 TWD 94 P2 TWD 95 P2 TWD 65 P2 TWD 105 P2 TWD 108 P2 TWD 99 P2 TWD 63 P2 TWD 98 P2 TWD 110 P2 TWD 112 P2 TWD 70 P2 TWD 78 P2 TWD 95 P2 TWD 95 P2 TWD 122 P2 TWD 109 P2 TWD 104 P2 TWD 113 P2 TWD 122 P2 TWD 113 P2 TWD 116 P2 TWD 101 P2 TWD 103 P2 TWD 121 P2 TWD 123 P2 TWD 116 P2 TWD 116 P2 TWD 97 P2 TWD 132 P2 TWD 122 P2 TWD 114 P2 TWD 123 P2 TWD 136 P2 TWD 103 P2 TWD 117 P2 TWD 105 P2 TWD 107 P2 TWD Ill P2 TWD 109 P2 TWD 107 P2 TWD 127 P2 TWD 119 P2 TWD 132 P2 TWD 144 P2 TWD 120 P2 TWD 124 P2 TWD 124 P2 TWD 148 P2 TWD 110 P2 TWD 141 P2 TWD 142 P2 TWD 132 P2 TWD 134 P2 TWD 118 P2 TWD 114 P2 TWD 138 P2 TWD

%TW LOCATION 14 AV3

+0.00 6

AV4

+0.00 7

AV5

+0.00 7

AV6

+0.00 5

AV7

+0.00 8

AV3

+0.00 8

AV4

+0.00 6

AVS

+0.00 6

AV7

+0.00 12 AV3

+0.00 9

AV4

+0.00 7

AV7

+0.00 12 AV4

+0.00 11 AV5

+0.00 5

AV6

+0.00 6

AV7

+0.00 6

AV2

+0.00 7

AVl

+0.00 19 AV2

+0.00 17 AV3

+0.00 8

AV7

+0.00 8

AV8

+0.00 6

AVi

+0.00 9

AV8

+0.00 15 AVE

+0.00 12 AVS

+0.00 6

AV7

+0.00 14 AVE

+0.00 13 AVS

+0.00 8

AV4

+0.00 7

AV3

+0.00 6

AV2

+0.00 6

AV8

+0.00 8

AV7

+0.00 5

AVE

+0.00 6

AVS

+0.00 8

AV4

+0.00 5

AV3

+0.00 6

AVI

+0.00 14 AV2

+0.00 8

AV3

+0.00 18 AV4

+0.00 12 AV6

+0.00 5

AVI

+0.00 9

AV2

+0.00 11 AV3

+0.00 9

AV4

+0.00 6

AVE

+0.00 6

AV7

+0.00 12 AV3

+0.00 13 AV4

+0.00 5

AV5

+0.00 7

AV6

+0.00 15 AV3

+0.00 7

AV4

+0.00 7

AV5

+0.00 7

AV1

+0.00 7

AV4

+0.00 5

AV2

-0.02 9

AV4

+0.00 10 AV3

+0.00 9

AV4

+0.00 10 AV4

+0.07 5

AV5

+0.00 6

AV2

+0.00 7

AV5

+0.05 5

AV5

+0.09 5

AV4

+0.05 7

AV4

+0.00 15 AV3

+0.00 8

AV7

+0.00 6

AV5

+0.00 8

AV3

-0.14 5

AV2

+0.00 5

AV3

+0.00 6

AV6

+0.00 6

AV7

+0.00 16 AV3

+0.00 12 AV4

+0.00 8

AV5

+0.00 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC UTIL 1

UTIL 2

CAL # LEG 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 7

COLD 7

COLD 7

COLD 7

COLD 7

COLD 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 NOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 11 NOT 11 HOT 11 HOT 11 HOT 11 HOT 10 HOT 58 COLD 58 COLD 13 COLD 11 COLD 8

COLD 8

COLD 8

COLD 8

COLD 8

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD PROBE 610UL 610UL 610UL 61OUL 61OUL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 6100L 610UL 610UL 610OL 610UL 610UL 610UL 610UL 610TDL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:35 Component: S/G B Page 28 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes), Enc. 8 Page 28 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 QUERY: QueryMl ROW COL VOLTS 100 79 0.22 0.22 100 81 0.14 0.31 0.35 0.60 0.20 100 83 0.16 0.43 0.18 0.16 0.22 100 85 0.12 0.31 0.56 0.60 0.12 0.48 100 87 0.25 0.67 0.52 0.17 100 89 0.14 0.16 0.16 0.40 0.18 100 91 0.29 0.27 0.17 100 93 0.39 0.37 0.15 100 95 0.35 0.16 0.26 0.23 0.19 0.24 100 97 0.13 0.34 0.41 0.14 100 99 0.13 0.19 0.63 0.32 0.25 100 101 0.18 0.18 100 103 0.15 0.30 0.48 0.48 0.35 100 135 0.13 0.15 101 30 0.26 101 46 0.16 101 48 0.11 101 52 0.12 101 62 0.13 101 64 0.21 0.13 0.14 0.12 101 66 0.14 101 70 0.11 101 74 0.11 0.31 0.16 101 76 0.26 0.34 101 80 0.16 101 82 0.22 101 86 0.70 0.45 0.17 0.34 101 88 0.16 DEG CHN 131 P2 123 P2 128 P2 117 P2 125 P2 118 P2 126 P2 133 P2 108 P2 123 P2 132 P2 116 P2 126 P2 121 P2 112 P2 124 P2 130 P2 117 P2 102 P2 116 P2 115 P2 90 P2 90 P2 128 P2 85 P2 106 P2 77 P2 106 P2 108 P2 129 P2 126 P2 126 P2 112 P2 121 P2 120 P2 130 P2 118 P2 122 P2 115 P2 129 P2 122 P2 125 P2 151 P2 140 P2 134 P2 123 P2 128 P2 118 P2 142 P2 130 P2 131 P2 125 P2 126 P2 118 P2 128 P2 92 P2 125 P2 117 P2 101 P2 145 P2 150 P2 144 P2 116 P2 104 P2 138 P2 82 P2 74 P2 106 P2 67 P2 112 P2 120 P2 109 P2 110 P2 77 P2 112 P2 108 P2 119 P2 97 P2 107 P2 117 P2 IND %TW LOCATION TWO 9 AV6

+0.00 TWD 9 AV7

+0.00 TWD 6 AV2

+0.00 TWD 12 AV3

+0.00 TWD 13 AV4

+0.00 TWD 19 AV5

+0.00 TWD 8 AV5

+0.00 TWD 7 AV6

+0.00 TWD 15 AV2

+0.00 TWD 7 AV6

+0.00 TWD 7 AV7

+0.00 TWD 9 AV8

+0.00 TWD 5 AVI

+0.00 TWD 12 AV2

+0.07 TWD 18 AV3

+0.00 TWD 19 AV4

+0.09 TWD 5 AV5

+0.09 TWD 17 AV6

+0.05 TWD 9 AV7

+0.00 TWD 19 AV6

+0.00 TWD 16 AV4

+0.00 TWD 7 AV3

+0.00 TWD 6 AV7

+0.00 TWD 6 AV6

+0.00 TWD 6 AV5

+0.00 TWD 13 AV4

+0.00 TWD 7 AV3

+0.00 TWD 10 AV5

+0.00 TWD 10 AV4

+0.00 TWD 6 AV7

+0.00 TWD 13 AVS

-0.02 TWD 12 AV4

-0.02 TWD 6 AV3

-0.07 TWD 12 AV7

+0.00 TWD 6 AV6

-0.14 TWD 9 AV5

-0.14 TWD 8 AV4

-0.09 TWD 7 AV3

+0.18 TWD 9 AV2

-0.11 TWD 5 AV4

-0.11 TWD 11 AV3

+0.05 TWD 13 AV2

+0.00 TWD 5 AV7

-0.09 TWD 5 AV7

+0.00 TWD 7 AV6

+0.00 TWD 18 AV4

+0.00 TWD 11 AV3

+0.00 TWD 9 AV2

+0.00 TWD 7 AV5

+0.00 TWD 7 AV3

+0.00 TWD 6 AV6

+0.00 TWD 10 AV5

+0.00 TWD 15 AV4

+0.00 TWD 15 AV3

+0.00 TWD 12 AV2

+0.00 TWD 5 AV5

+0.00 TWD 6 AV4

+0.00 TWD 10 AVI

-0.12 TWD 6 AV6

+0.12 TWD 5 AV5

+0.00 TWD 5 AV4

-0.02 TWD 6 AV4

+0.00 TWD 11 AV7

+0.00 TWD 7 AV6

+0.00 TWD 7 AV4

+0.00 TWD 7 AV3

+0.25 TWD 7 AV6

+0.23 TWD 5 AV5

+0.07 TWD 6 AVI

+0.19 TWD 14 AV3

+0.12 TWD 8 AV6

+0.07 TWD 12 AV3

+0.00 TWD 15 AV4

+0.00 TWD 8 AV4

+0.00 TWD 11 AV7

+0.00 TWD 19 AV7

+0.00 TWD 14 AV6

+0.00 TWD 6 AV3

+0.00 TWD 12 AV2

+0.00 TWD 6 AV7

+0.00 EXT EXT TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL #

6 6

6 6

6 6

6 6

6 6

6 6

4 4

4 4

4 4

16 16 16 16 15 15 15 15 15 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 10 10 57 11 11 11 10 9

9 9

9 9

8 9

9 9

7 7

7 7

16 16 16 16 16 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD NOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD NOT HOT HOT HOT HOT PROBE 610 UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610DL 610UL 610UL 610UL 610UL 610UL 610UL 61DUL 610TDL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:35 Component: S/G B Page 29 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 29 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.28 0.20 0.12 0.13 0.11 101 90 0.25 0.13 0.14 0.37 0.14 0.14 101 92 0.22 0.11 0.36 0.13 0.29 0.23 101 94 0.22 0.27 0.34 0.20 0.19 101 96 0.20 0.19 0.32 0.34 101 98 0.22 0.43 0.53 0.64 0.33 101 100 0.25 0.21 101 104 0.47 0.59 101 106 0.13 0.14 101 108 0.12 101 110 0.15 101 112 0.27 0.14 101 118 0.18 0.11 102 31 0.12 102 47 0.12 102 51 0.19 102 55 0.12 102 65 0.15 0.14 102 73 0.22 102 75 0.10 0.13 102 77 0.17 0.17 0.16 102 79 0.16 102 81 0.48 0.20 102 83 0.19 102 85 0.51 0.56 0.24 0.45 0.23 0.19 102 87 0.26 0.52 0.25 0.16 102 89 0.21 0.31 0.57 0.38 0.33 102 91 0.31 0.37 0.23 0.11 102 93 0.10 0.12 DEG CHN 120 P2 115 P2 125 P2 98 P2 88 P2 111 P2 98 P2 122 P2 109 P2 79 P2 92 P2 133 P2 116 P2 130 P2 147 P2 109 P2 129 P2 137 P2 128 P2 133 P2 106 P2 110 P2 144 P2 138 P2 113 P2 112 P2 118 P2 126 P2 131 P2 122 P2 125 P2 137 P2 120 P2 125 P2 124 P2 127 P2 111 P2 135 P2 129 P2 127 P2 106 P2 122 P2 85 P2 130 P2 147 P2 133 P2 149 P2 74 P2 92 P2 92 P2 131 P2 66 P2 120 P2 61 P2 119 P2 122 P2 116 P2 109 P2 129 P2 93 P2 104 P2 67 P2 111 P2 85 P2 53 P2 99 P2 109 P2 101 P2 85 P2 82 P2 104 P2 115 P2 115 P2 118 P2 115 P2 106 P2 92 P2 105 P2 76 P2 123 P2 IND %TW TWD 10 TWD 7 TWD 5 TWD 5 TWD 4 TWD 9 TWD 5 TWD 5 TWD 12 TWD 5 TWD 5 TWD 8 TWD 4 TWD 12 TWD 5 TWO 10 TWD 8 TWD 8 TWD 9 TWD 11 TWD 7 TWD 7 TWD 7 TWD 7 TWD 11 TWD 11 TWD 8 TWD 14 TWD 16 TWD 18 TWD 11 TWD 9 TWD 8 TWD 15 TWD 18 TWD 5 TWD 5 TWD 5 TWD 6 TWD 10 TWD 5 TWD 7 TWD 4 TWD 5 TWD 5 TWD 8 TWD 5 TWD 8 TWD 8 TWD 11 TWD 5 TWD 7 TWD 8 TWD 8 TWD 8 TWD 8 TWD 19 TWD 10 TWD 9 TWD 17 TWD 18 TWD 9 TWD 15 TWD 9 TWD 8 TWD 10 TWD 16 TWD 9 TWD 6 TWD 8 TWD 11 TWD 17 TWD 13 TWD 11 TWD 11 TWD 13 TWD 9 TWD 5 TWD 4 TWD 5 LOCATION AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

-0.11 AV2

+0.00 AV8

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV2

+0.00 AV7

-0.14 AV6

+0.07 AV5

+0.00 AV4

-0.05 AV3

+0.09 AV2

-0.35 AV7

-0.11 AV6

-0.09 AV4

-0.07 AV3

+0.07 AV2

-0.14 AV5

-0.02 AV4

-0.09 AV3

-0.09 AV2

+0.16 AV8

+0.00 AV5

+0.00 AV4

+0.00 AV2

+0.00 AVl

+0.00 AV4

+0.00 AV2

+0.00 AV5

-0.05 AV4

-0.11 AV5

+0.00 AV2

+0.00 AV5

-0.02 AV5

+0.00 AV3

+0.16 AV2

+0.09 AV4

-0.07 AV3

+0.00 AV3

+0.14 AV4

+0.00 AV4

+0.05 AV5

+0.11 AV2

+0.05 AV4

+0.07 AV5

+0.09 AVI

+0.00 AV2

+0.00 AV4

+0.00 AV5

+0.00 AV7

+0.00 AV4

+0.00 AV5

+0.00 AV7

+0.00 AV3

+0.00 AVl

+0.02 AV2

+0.05 AV3

+0.05 AV4

+0.07 AV5

+0.12 AV8

+0.02 AV7

+0.00 AV4

+0.00 AV2

+0.00 AVI

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV7

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AVI

+0.00 AV2

+0.00 EXT TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC EXT TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH UTIL 1

UTIL 2

CAL #

16 16 16 16 16 16 16 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 12 12 12 12 12 12 12 12 10 10 57 57 58 57 9

9 9

7 7

7 7

7 7

7 7

7 5

5 5

5 5

5 15 15 15 15 16 16 16 16 16 15 15 15 15 13 13 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610TDL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610DL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:35 Component: S/G B Page 30 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 30 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.27 102 95 0.16 0.11 0.14 0.12 0.13 0.10 102 97 0.12 0.40 0.43 0.27 102 99 0.17 102 109 0.32 0.25 102 113 0.11 102 119 0.15 0.14 103 44 0.11 103 52 0.12 103 54 0.13 0.11 103 56 0.12 103 60 0.11 103 66 0.22 0.14 103 72 0.16 0.13 103 74 0.18 0.29 0.24 0.18 103 76 0.19 0.16 0.18 103 78 0.18 103 80 0.12 103 82 0.12 0.12 0.20 103 84 0.18 0.51 0.61 0.53 0.18 103 86 0.38 0.38 0.18 0.54 103 88 0.43 0.29 0.43 0.28 0.14 0.22 103 90 0.13 0.13 0.19 103 92 0.12 0.13 0.21 103 94 0.12 0.41 0.29 0.13 103 96 0.27 0.44 0.11 103 98 0.21 0.23 103 100 0.11 0.16 103 110 0.12 103 120 0.16 103 124 0.14 103 126 0.17 104 49 0.12 104 59 0.14 104 61 0.12 0.13 104 73 0.16 DEG CHN 114 P2 125 P2 116 P2 98 P2 122 P2 116 P2 77 P2 117 P2 109 P2 114 P2 112 P2 136 P2 112 P2 113 P2 113 P2 75 P2 111 P2 147 P2 143 P2 144 P2 151 P2 102 P2 88 P2 134 P2 120 P2 115 P2 124 P2 130 P2 113 P2 134 P2 99 P2 130 P2 125 P2 131 P2 145 P2 149 P2 88 P2 105 P2 129 P2 133 P2 115 P2 118 P2 116 P2 137 P2 105 P2 108 P2 82 P2 114 P2 112 P2 90 P2 105 P2 96 P2 71 P2 76 P2 118 P2 63 P2 123 P2 142 P2 97 P2 111 P2 121 P2 103 P2 115 P2 101 P2 104 P2 109 P2 82 P2 115 P2 96 P2 132 P2 120 P2 83 P2 120 P2 117 P2 121 P2 148 P2 132 P2 143 P2 136 P2 137 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW LOCATION 10 Av4

+0.00 6

AV2

+0.00 6

AV3

+0.00 6

AV4

+0.00 5

AVS

+0.00 5

AV6

+0.00 4

AV7

+0.00 5

AVi

+0.00 14 AV2

+0.00 14 AV3

+0.00 10 AV4

+0.00 7

AV4

+0.00 11 AV2

-0.02 9

AV3

+0.00 5

AV5

-0.07 6

AV5

+0.09 5

AV4

-0.09 5

AV5

+0.09 5

AV3

+0.09 6

AV3

+0.00 5

AV5

+0.12 5

AV5

+0.09 5

AV4

-0.14 9

AV4

+0.00 6

AV2

+0.00 7

AV4

+0.00 6

AV6

+0.07 8

AV3

+0.00 11 AV5

+0.16 10 AV6

+0.00 8

AV7

+0.00 8

AV4

+0.00 7

AV5

+0.00 7

AV6

+0.00 7

AV5

+0.00 5

AVI

+0.00 5

AV7

+0.12 5

AV3

+0.00 8

AV5

+0.00 7

AVI

+0.00 17 AV2

+0.00 19 AV4

+0.00 17 AV6

+0.00 8

AV8

+0.00 13 AV7

+0.00 13 AV6

+0.00 7

AV3

+0.00 17 AV2

+0.00 14 AV8

+0.00 10 AV7

+0.00 14 AV6

+0.00 10 AV5

+0.00 6

AV4

+0.00 8

AV3

+0.00 5

AV5

+0.00 5

AV3

+0.00 7

AV2

+0.00 5

AVI

+0.00 5

AV2

+0.18 8

AV3

+0.00 5

AV2

-0.05 14 AV3

+0.00 11 AV4

+0.00 5

AV5

+0.00 10 AV3

+0.00 15 AV4

+0.00 4

AV5

+0.00 8

AV4

+0.00 9

AV5

+0.00 4

AV6

+0.00 7

AV7

+0.00 5

AV5

-0.05 6

AV4

+0.00 5

AV5

+0.00 6

AV4

+0.00 5

AV3

+0.00 6

AV4

+0.07 5

AV4

+0.12 6

AV3

-0.05 7

AV2

+0.00 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC UTIL 1 UTIL 2

CAL # LEG 13 NOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 11 HOT 11 NOT 12 HOT 10 HOT 10 HOT 13 COLD 57 COLD 57 COLD 57 COLD 58 COLD 10 COLD 8

COLD 8

COLD 8

COLD 8

COLD 8

COLD 8

COLD 8

COLD 8

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 11 HOT 10 HOT 10 HOT 10 HOT 11 COLD 10 COLD 10 COLD 10 COLD 8

COLD PROBE 610UL 610TUL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TDL 610UL 610UL 610TUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TDL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TDL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:35 Component: S/G B Page 31 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 31 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.11 0.21 104 75 0.13 104 77 0.20 0.15 0.14 0.17 104 79 0.13 0.11 104 81 0.51 0.15 0.23 0.35 0.23 104 83 0.38 0.17 0.62 0.11 104 85 0.22 0.44 0.23 104 87 0.11 0.18 0.48 0.16 0.18 0.14 104 89 0.23 0.16 0.20 0.25 0.16 104 91 0.19 0.37 0.45 0.28 0.15 104 93 0.22 104 95 0.19 0.18 0.26 0.43 0.23 104 97 0.19 0.27 0.41 0.23 0.24 104 99 0.18 0.19 0.52 0.24 0.15 104 107 0.14 104 121 0.08 105 54 0.16 105 58 0.14 105 64 0.11 105 70 0.16 105 72 0.15 0.44 0.27 105 74 0.13 105 78 0.27 0.12 0.11 0.20 105 80 0.13 105 82 0.49 0.20 0.19 0.27 0.17 105 84 0.15 0.22 0.51 0.44 0.18 0.21 105 86 0.34 DEG 152 134 132 130 132 127 133 138 138 125 132 128 124 128 117 93 127 102 146 121 122 99 117 103 99 93 138 130 137 117 144 90 122 118 110 103 88 127 128 130 133 123 115 125 127 133 136 137 139 133 128 125 130 129 127 137 145 97 144 92 ill 101 98 92 113 78 100 88 104 91 108 103 76 85 101 96 107 97 90 97 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW LOCATION TWD 5 AV3

+0.00 TWD 9 AV4

+0.00 TWD 6 AV5

+0.00 TWD 8 AV4

+0.00 TWD 6 AV5

+0.00 TWD 6 AV6

+0.00 TWD 7 AV7

+0.00 TWD 5 AV2

+0.00 TWD 5 AV3

+0.00 TWD 17 AV3

+0.00 TWD 6 AV4

+0.00 TWD 9 AV5

+0.00 TWD 13 AV6

+0.00 TWD 9 AV7

+0.00 TWD 14 AV8

+0.00 TWD 7 AV3

+0.00 TWD 19 AV5

+0.00 TWD 5 AV7

+0.00 TWD 9 AV2

+0.00 TWD 16 AV6

+0.00 TWD 10 AV7

+0.07 TWD 4 AV8

+0.00 TWD 7 AV6

+0.00 TWD 15 AV4

+0.00 TWD 6 AV3

+0.00 TWD 7 AV2

+0.00 TWD 5 AVI

+0.00 TWD 9 AV7

+0.00 TWD 6 AV6

+0.00 TWD 8 AV5

+0.09 TWD 9 AV4

+0.02 TWD 6 AV3

+0.00 TWD 7 AV5

+0.00 TWD 12 AV4

+0.00 TWD 14 AV3

+0.00 TWD 10 AV2

+0.00 TWD 6 AVI

-0.21 TWD 8 AV3

+0.14 TWD 7 AV7

-0.05 TWD 7 AV4

-0.11 TWD 9 AV3

+0.02 TWD 14 AV2

-0.02 TWD 8 AVl

-0.05 TWD 7 AV6

-0.07 TWD 10 AV5

+0.00 TWD 13 AV4

-0.14 TWD 8 AV3

+0.05 TWD 9 AV2

-0.02 TWD 7 AV7

+0.00 TWD 7 AV6

+0.00 TWD 16 AV3

+0.00 TWD 9 AV2

+0.00 TWD 6 AVI

+0.00 TWD 5 AV4

+0.00 TWD 3 AV4

-0.23 TWD 7 AV5

+0.02 TWD 6 AV3

+0.05 TWD 6 AV5

+0.21 TWD 7 AV6

+0.07 TWD 8 AV2

+0.02 TWD 18 AV3

+0.09 TWD 13 AV5

+0.12 TWD 7 AV4

-0.16 TWD 12 AV2

+0.00 TWD 6 AV3

+0.00 TWD 6 AV4

+0.00 TWD 10 AV5

+0.00 TWD 7 AV6

+0.00 TWD 19 AV3

+0.00 TWD 10 AV4

+0.00 TWD 9 AV5

+0.00 TWD 13 AV6

+0.00 TWD 8 AV7

+0.00 TWD 8 AVI

+0.00 TWD 10 AV2

+0.00 TWD 19 AV3

+0.00 TWD 17 AV4

+0.00 TWD 9 AV7

+0.00 TWD 10 AV8

+0.00 TWD 12 AV8

+0.00 EXT EXT UTIL TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH 1 UTIL 2

CAL 8

8 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 4

4 4

16 16 16 16 16 16 41 41 41 41 41 16 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 12 9

11 10 9

8 9

9 9

9 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

7 16

  1. LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD.

COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:35 Component: S/G B Page 32 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tribes), Enc. 8 Page 32 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 QUERY: QueryMl ROW COL VOLTS DEG 0.69 112 0.23 106 0.41 115 105 88 0.18 105 0.17 119 0.36 110 0.26 120 0.22 123 105 90 0.15 105 0.30 109 0.14 78 0.24 83 0.15 115 0.12 102 105 92 0.13 96 0.18 134 0.14 131 0.29 124 0.17 126 0.16 136 105 94 0.17 119 0.23 128 0.17 128 0.26 108 0.20 118 0.16 132 105 96 0.20 135 0.20 132 0.31 126 0.38 127 0.24 123 105 98 0.18 102 0.23 121 0.25 134 0.33 127 0.22 129 0.14 131 105 100 0.18 119 0.18 138 0.23 126 105 108 0.13 108 105 112 0.11 129 0.22 117 105 118 0.15 83 106 33 0.16 140 106 53 0.13 123 0.23 123 0.16 128 0.13 117 0.16 137 106 55 0.18 114 0.16 129 106 57 0.19 138 106 59 0.17 142 106 61 0.14 146 106 71 0.12 75 0.22 105 106 73 0.10 75 0.16 140 0.14 136 0.12 101 106 81 0.16 90 0.40 118 0.34 120 0.27 102 0.32 109 106 83 0.17 98 0.15 63 0.45 107 106 85 0.32 126 0.16 121 0.14 134 0.53 119 106 87 0.16 137 0.14 144 0.53 115 0.24 120 0.15 133 0.27 123 0.23 119 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWD 19 TWD 9 TWD 13 TWD 7 TWD 7 TWD 12 TWD 9 TWD 8 TWD 6 TWD 10 TWD 5 TWD 9 TWD 6 TWD 5 TWD 5 TWD 7 TWD 5 TWD 10 TWD 6 TWD 6 TWD 6 TWD 8 TWD 6 TWD 9 TWD 7 TWD 6 TWD 7 TWD 7 TWD 11 TWD 12 TWD 9 TWD 7 TWD 8 TWD 9 TWD 11 TWD 8 TWD 5 TWD 7 TWD 7 TWD 8 TWD 5 TWD 5 TWD 8 TWD 6 TWD 6 TWD 5 TWD 9 TWD 6 TWD 5 TWD 7 TWD 8 TWD 7 TWD 8 TWD 7 TWD 6 TWD 7 TWD 11 TWD 6 TWD 8 TWD 7 TWD 6 TWD 8 TWD 17 TWD 15 TWD 12 TWD 14 TWD 9 TWD 8 TWD 18 TWD 12 TWD 7 TWD 6 TWD 18 TWD 6 TWD 6 TWD 17 TWD 9 TWD 6 TWD 10 TWD 9 LOCATION AV6

+0.00 AV3

+0.00 AV2

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

-0.12 AVI

-0.37 AV8

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV2

+0.00 AV7

-0.23 AV6

-0.02 AV4

-0.05 AV3

+0.00 AV2

-0.12 AVI

-0.14 AV7

-0.09 AV6

-0.09 AV5

-0.05 AV4

-0.14 AV3

+0.07 AV2

-0.30 AV6

-0.07 AV4

-0.07 AV3

-0.02 AV2

-0.02 AVI

+0.02 AV7

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AVI

+0.00 AV7

+0.00 AV6

+0.00 AV4

+0.00 AV5

+0.00 AV5

+0.00 AV3

+0.00 AV4

+0.00 AV6

+0.12 AVI

+0.09 AV2

+0.07 AV3

+0.11 AV4

+0.02 AV5

+0.16 AV4

+0.11 AV5

+0.11 AV4

+0.14 AV5

+0.16 AVS

+0.05 AV3

-0.09 AV4

+0.07 AV3

+0.00 AV4

+0.00 AV5

+0.07 AV6

+0.07 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AVI

+0.00 AV2

+0.00 AV5

+0.00 AVI

+0.05 AV3

+0.07 AV5

+0.00 AV6

+0.00 AV8

+0.00 AV7

-0.04 AV6

+0.07 AV5

+0.00 AV4

-0.07 AV2

+0.00 AVI

+0.00 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1 UTIL 2

CAL #

16 16 16 16 16 16 16 16 16 16 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 12 12 12 10 57 57 57 57 57 57 58 58 10 10 10 9

9 9

9 9

9 7

7 7

7 7

7 7

7 4

4 4

4 41 41 41 41 41 41 41 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 610UL 61OUL 610 UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UU 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 61OUL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UDL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:35 Component: S/G B Page 33 of 48 Component: S/C B Page 33 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 33 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 106 89 0.34 0.20 0.20 0.19 0.13 106 91 0.26 0.20 0.19 106 93 0.14 0.31 0.17 0.21 0.18 106 95 0.23 0.20 0.46 0.34 106 97 0.23 0.54 0.49 0.32 106 101 0.15 106 111 0.19 106 119 0.14 107 34 0.13 0.11 0.16 107 56 0.12 107 60 0.16 107 64 0.12 107 68 0.21 0.14 107 74 0.22 107 76 0.15 0.37 0.46 107 78 0.14 0.21 107 80 0.15 0.12 0.24 107 82 0.16 0.43 0.58 0.42 0.18 0.21 0.11 107 84 0.21 0.51 0.59 107 88 0.19 0.21 0.47 0.44 0.28 0.19 0.18 107 90 0.16 0.19 0.18 0.16 0.17 0.13 107 92 0.30 0.17 0.35 0.13 107 94 0.11 0.33 0.12 0.31 0.16 107 96 0.19 0.17 107 98 0.24 0.13 0.23 0.13 107 100 0.13 DEG 85 73 79 83 63 109 80 96 129 117 110 124 126 107 123 114 127 124 120 112 103 140 122 131 122 133 132 144 126 109 124 132 93 135 116 121 135 112 115 146 119 139 107 124 131 124 125 139 118 107 123 63 89 107 108 84 68 110 94 92 104 94 80 56 108 110 122 115 126 106 74 125 125 122 118 92 103 101 124 128 CHN IND %TW LOCATION P2 TWO 12 AV7 40.00 P2 TWD 8 AV6

+0.00 P2 TWD 8 AV5

+0.00 P2 TWD 7 AV4

+0.00 P2 TWD 5 AV3

+0.00 P2 TWD 10 AV7

+0.00 P2 TWD 8 AV5

+0.00 P2 TWD 7 AV4

+0.00 P2. TWD 6 AVI

-0.16 P2 TWD 11 AV2

+0.00 P2 TWD 7 AV3

+0.00 P2 TWD 8 AV4

+0.00 P2 TWD 7 AV5

+0.00 P2 TWD 9 AV2

+0.00 P2 TWD 8 AV3

+0.00 P2 TWD 15 AV4

+0.00 P2 TWD 12 AV5

+0.00 P2 TWD 9 AVI

+0.00 P2 TWD 17 AV2

+0.00 P2 TWD 16 AV4

+0.00 P2 TWD 12 AV5

+0.00 P2 TWD 6 AV5

+0.00 P2 TWD 7 AV5

+0.00 P2 TWD 5 AV4

-0.05 P2 TWD 6 AVI

-0.14 P2 TWD 5 AV6

+0.05 P2 TWD 6 AV8

+0.05 P2 TWD 5 AV3

+0.00 P2 TWD 7 AV4

+0.09 P2 TWD 5 AV5

+0.00 P2 TWD 9 AV3

+0.00 P2 TWD 6 AV2

+0.00 P2 TWD 9 AV3

+0.00 P2 TWD 6 AV2

+0.00 P2 TWD 13 AV3

+0.00 P2 TWD 16 AV4

+0.00 P2 TWD 6 AVI

+0.00 P2 TWD 8 AV3

+0.00 P2 TWD 6 AV4

+0.00 P2 TWD 5 AV6

+0.00 P2 TWD 9

AV7

+0.00 P2 TWD 7 AV2

+0.00 P2 TWD 15 AV3

+0.00 P2 TWD 18 AV4

+0.00 P2 TWD 15 AV5

+0.00 P2 TWD 8 AV6

+0.00 P2 TWD 9 AV7

+0.00 P2 TWD 5 AV8

+0.00 P2 TWD 8 AV2

+0.00 P2 TWD 17 AV3

+0.00 P2 TWD 19 AV7

+0.00 P2 TWD 7 AV7

+0.00 P2 TWD 8 AV6

+0.00 P2 TWD 15 AV5

+0.00 P2 TWD 14 AV4

+0.00 P2 TWD 10 AV3

+0.00 P2 TWD 7 AV2

+0.00 P2 TWD 7 AVl

+0.00 P2 TWD 6 AV7

+0.00 P2 TWD 7 AV5

+0.00 P2 TWD 7 AV4

+0.00 P2 TWD 6 AV3

+0.00 P2 TWD 7 AV2

+0.00 P2 TWD 5 AVI

+0.00 P2 TWD 11 AV2

+0.00 P2 TWD 7 AV3

-0.25 P2 TWD 12 AV4

+0.00 P2 TWD 5 AV7

+0.09 P2 TWD 5 AVI

+0.00 P2 TWO 12 AV2

+0.00 P2 TWD 5 AV3

+0.00 P2 TWD 11 AV4

+0.00 P2 TWD 6 AV6

+0.00 P2 TWD 7 AV3

+0.00 P2 TWD 7 AV4

+0.00 P2 TWD 9 AV2

+0.00 P2 TWD 5 AV3

+0.00 P2 TWD 9 AV4

+0.00 P2 TWD 5 AV6

+0.00 P2 TWD 5 AV2

+0.00 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL CAL 15 15 15 15 15 15 15 15 13 13 13 13 13 13 13 13 13 13 13 13 13 13 12 10 57 57 57 10 10 8

8 8

8 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 15 15 15 15 15 15 15 15 15 15 15 15 15 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13

  1. LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 6100L 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:35 Component: S/G B Page 34 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 34 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.60 0.25 0.24 107 102 0.45 0.17 107 120 0.12 107 128 0.15 0.14 108 35 0.13 0.11 108 45 0.14 108 57 0.11 108 61 0.13 0.12 108 65 0.17 0.13 108 71 0.16 0.14 108 73 0.16 108 75 0.14 108 77 0.20 0.19 0.22 0.11 108 79 0.14 0.13 108 81 0.13 108 83 0.22 0.28 0.50 0.62 0.46 0.32 0.28 108 85 0.18 0.16 0.25 0.42 0.53 108 87 0.18 0.46 0.57 0.32 108 89 0.22 0.41 0.37 0.15 0.11 0.14 108 91 0.41 0.65 0.34 0.12 108 93 0.47 0.38 0.36 0.24 108 95 0.31 0.66 0.20 0.34 108 97 0.22 0.19 108 99 0.18 0.22 0.13 108 101 0.37 0.27 0.14 108 103 0.38 0.20 108 105 0.16 108 107 0.16 109 48 0.11 0.11 109 62 0.16 0.14 109 64 0.13 109 68 0.18 0.17 DEG 122 117 121 115 107 129 118 114 121 136 140 142 144 129 132 144 141 143 140 140 121 124 139 137 130 140 124 109 120 121 125 117 123 115 84 110 127 119 118 57 106 99 113 102 112 117 88 64 128 110 119 103 125 120 123 128 121 119 120 117 125 135 137 139 128 127 133 118 ill 130 125 130 144 127 149 140 138 82 102 108 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW LOCATION 18 AV3 9

AV4 9

AV7 15 AV3 7

AV6

+

5 AV3 6

AV5 5

AV4 5

AV2

+

5 AV7

+

6 AV3

+

5 AV5 6

AV3 5

AV5 7

AV4 6

AV3 7

AV6 6

AV5 7

AV5 6

AV3 8

AV2 8

AV3 9

AV5 5

AV6 6

AV4 6

AV6 5

AV2 9

AVI 11 AV2 17 AV3 19 AV4 16 AV6 12 AV7 11 AV8 8

AVI 7

AV3 10 AV5 15 AV6 18 AV7 7

AV7 15 AV6 17 AV5 11 AV4 8

AV7 13 AV6 12 AV5 6

AV4 4

AV3 5

AV2 13 AV5 19 AV4 11 AV3 5

AV2 15 AV4 12 AV3 12 AV2 9

AVI 11 AV5 19 AV4 7

AVl 12 AV2 8

AV5 7

AV4 7

AV5 8

AV4 5

AV3 12 AV5 10 AV3 5

AV2 13 AV5 7

AV3 6

AV5 6

AV5 5

AV6 5

AV5 7

AV5 6

AV4 7

AV5 9

AV4 9

AV6 0.00 0.00 0.00

.000

.000

-0.05

0. 00
0. 00 0.23 0.02

+0.00 0.05 r0.02

+0.00

+0.00 r0.00 r0.00 H0.00 H0.00 r0.00

+0.00 H0.00

+0.00

+0.00 H0.00 H0.00

+0.00 H0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.02

+0.07

+0.00

+0.09

+0.07

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

-0.09

-0.02

+0.00

+0.00

-0.07

-0.07

+0.00

+0.02

-0.05

-0.14

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

-0.02

+0.00

+0.00

-0.02

+0.00

+0.00

+0.09

+0.05

+0.25

+0.05

+0.09 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC UTIL 1

UTIL 2

CAL #

13 13 13 13 13 10 10 10 57 57 13 10

.10 10 8

8 8

8 8

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 4

4 4

4 4

15 15 15 15 16 16 16 16 16 16 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 12 12 11 11 10 10 9

9 9

LEG HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD PROBE 610UL 61OUL 610UL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 6 10 UL 610UL 610UL 610UL 610UL 61OUL 61OUL 61OUL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:35 Component: S/G B Page 35 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 35 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 109 70 0.15 109 72 0.18 0.31 109 74 0.13 109 76 0.24 109 80 0.13 0.12 109 82 0.14 0.33 0.50 0.13 109 84 0.38 0.29 0.51 0.31 0.29 109 86 0.25 0.34 0.31 109 88 0.14 0.25 0.20 0.18 0.14 109 90 0.15 0.22 0.12 0.14 0.26 109 92 0.17 0.13 0.42 0.26 0.21 109 94 0.20 0.48 0.33 0.28 0.33 0.17 109 96 0.35 0.14 0.16 109 98 0.14 0.23 0.37 0.16 109 100 0.22 0.49 0.29 0.36 0.34 0.33 0.14 109 104 0.12 109 106 0.12 109 110 0.11 109 116 0.12 110 53 0.14 110 59 0.16 0.14 110 69 0.15 0.17 110 71 0.13 0.12 110 75 0.21 110 77 0.14 0.26 0.16 0.15 110 81 0.15 110 83 0.42 110 85 0.39 0.25 110 87 0.35 0.53 0.22 0.43 0.63 110 89 0.30 DEG 118 120 106 76 120 43 131 68 117 109 120 91 81 112 113 97 96 101 94 97 127 86 94 129 103 123 123 116 110 102 139 130 122 130 135 131 127 120 129 122 124 99 137 138 134 127 129 118 122 114 124 124 124 143 149 140 ill 118 131 137 131 124 127 108 98 96 101 83 103 102 85 92 122 123 116 105 105 115 117 73 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW 7

8 14 7

11 7

6 7

14 19 7

16 13 19 14 13 9

12 11 5

9 8

7 5

6 8

5 5

9 6

5 13 9

8 7

15 11 10 11 6

12 5

6 5

8 12 6

8 15 10 12 11 11 5

5 5

5 5

6 7

6 7

7 7

7 10 7

12 8

8 8

17 14 10 12 16 8

14 18 11 LOCATION AV3

+0.00 AV4

+0.05 AVS

+0.12 AV3

+0.19 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AVS

+0.00 AV7

+0.00 AVI

+0.00 AV2

+0.00 AV3

+0.00 AV6

+0.00 AV8

+0.00 AV8

+0.00 AV3

+0.00 AV2

+0.00 AV6

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AVi

-0.32 AV8

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV7

-0.25 AV6

+0.02 AV4

-0.07 AV3

-0.07 AV2

+0.07 AV6

-0.07 AV5

-0.02 AV4

-0.05 AV3

+0.05 AV2

+0.05 AVi

-0.07 AV4

-0.12 AV3

-0.09 AV2

+0.07 AV6

+0.00 AV5

+0.00 AV2

+0.00 AVI

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AVI

+0.00 AV8

+0.00 AV2

+0.00 AV2

+0.00 AV3

+0.00 AV5

+0.00 AV5

+0.09 AV4

+0.07 AVS

+0.00 AV4

+0.00 AV3

-0.07 AV4

-0.12 AV5

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV4

+0.00 AV6

+0.00 AV2

+0.09 AV6

+0.00 AV8

+0.00 AV7

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV7

+0.00 EXT EXT TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1 UTIL 2

CAL 8

9 9

9 7

7 7

7 7

7 7

7 7

7 7

7 15 15 15 16 16 16 16 16 16 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 12 12 12 57 10 10 8

8 9

9 7

7 7

7 7

7 7

4 4

16 16 16 16 16 15

  1. LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT PROBE 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610DL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UDL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:36 Component: S/G B Page 36 of 48 Component: S/C B Page 36 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 36 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.61 0.15 110 91 0.34 0.21.

0.30 110 93 0.20 0.32 0.25 110 95 0.21 0.24 0.18 110 97 0.46 110 99 0.16 0.24 0.39 110 101 0.12 0.25 0.35 0.17 0.42 110 103 0.10 110 113 0.12 110 127 0.13 0.19 111 72 0.11 111 74 0.26 111 76 0.20 0.19 111 78 0.15 0.35 111 80 0.11 111 82 0.13 0.19 111 84 0.12 0.52 0.49 111 86 0.52 0.19 0.24 0.26 111 88 0.22 0.26 0.38 0.26 0.14 11 90 0.22 0.29 0.20 111 92 0.20 0.13 0.10 111 94 0.17 0.30 0.17 0.15 111 96 0.24 0.22 0.21 0.50 0.14 111 98 0.27 0.27 0.41 0.24 0.09 I11 102 0.27 0.14 0.42 111 128 0.16 0.22 112 69 0.31 0.35 0.28 0.14 112 71 0.16 0.19 0.18 112 73 0.41 0.26 0.55 DEG 105 63 92 101 87 122 122 91 121 104 117 126 119 129 115 88 ill 108 128 116 141 103 125 131 145 128 116 130 132 126 120 107 129 139 119 116 120 115 124 119 100 109 105 88 90 89 101 ill 118 125 124 76 117 120 119 108 114 115 113 137 113 108 121 115 93 120 115 122 76 95 118 115 117 76 144 136 125 126 101 110 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW LOCATION TWD 18 AV5

+0.00 TWD 6 AV4

+0.00 TWD 12 AV5

+0.00 TWD 8 AV6

+0.00 TWD 11 AV7

+0.00 TWD 8 AV2

+0.00 TWD 11 AV4

+0.00 TWD 9 AV7

+0.00 TWD 8 AV2

+0.00 TWD 9 AV3

+0.00 TWD 7 AV5

+0.00 TWD 15 AV3

+0.00 TWD 6 AV3

+0.00 TWD 9 AV4

+0.00 TWD 13 AV5

+0.00 TWD 5 AVI

+0.00 TWD 9 AV2

+0.00 TWD 12 AV3

+0.00 TWD 7 AV4

+0.00 TWD 14 AV5

+0.00 TWD 4 AV2

+0.00 TWD 5 AV4

-0.02 TWD 5 AV7

+0.00 TWD 7 AV4

-0.02 TWD 5 AV6

+0.05 TWD 10 AV3

+0.00 TWD B AV2

+0.00 TWD 8 AV4

+0.00 TWD 6 AV3

+0.00 TWD 13 AV4

+0.00 TWD 5 AV7

+0.00 TWD 6 AV3

+0.00 TWD 8 AV5

+0.00 TWD 5 AV2

+0.00 TWD 17 AV6

+0.00 TWD 16 AV7

+0.00 TWD 16 AV8

+0.00 TWD 7 AV5

+0.00 TWD 9 AV3

+0.00 TWD 9 AV2

+0.00 TWD 8 AV6

+0.00 TWD 10 AV5

+0.00 TWD 13 AV4

+0.00 TWD 9 AV3

+0.00 TWD 6 AV2

+0.00 TWD 8 AV6

+0.00 TWD 10 AV5.

+0.00 TWD 8 AV3

+0.00 TWD 8 AV2

+0.00 TWD 5 AV3

-0.05 TWD 4 AV7

+0.07 TWD 7 AV2

+0.00 TWD 11 AV3

+0.00 TWD 7 AV4

+0.00 TWD 6 AV6

+0.00 TWD 9 AVI

+0.00 TWD 8 AV2

+0.00 TWD 8 AV3

+0.00 TWD 16 AV4

+0.00 TWD 6 AV7

+0.00 TWD 10 AV2

+0.00 TWD 10 AV3

+0.00 TWD 14 AV4

+0.00 TWD 9 AV5

+0.00 TWD 4 AV6

+0.00 TWD 10 AV3

+0.00 TWD 6 AV4

+0.00 TWD 14 AV5

+0.00 TWD 6 AV5

+0.00 TWD 8 AV4

+0.00 TWD 14 AVI

+0.07 TWD 15 AV2

+0.02 TWD 13 AV3

+0.09 TWD 7 AV4

-0.16 TWD 7 AV6

+0.07 TWD 8 AV4

+0.00 TWD 8 AV3

+0.00 TWD 15 AVl

+0.00 TWD 11 AV2

+0.00 TWD 18 AV3

+0.00 EXT EXT TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC UTIL 1

UTIL 2

CAL # LEG 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 12 HOT 10 HOT 10 HOT 8

COLD 8

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 16 HOT 16 HOT 16 HOT 16 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 10 HOT 10 HOT

9.

COLD 9

COLD 9

COLD 9

COLD 8

COLD 8

COLD 8

COLD 8

COLD 8

COLD 8

COLD PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610OL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 6100L 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:36 Component: S/G B Page 37 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 37 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.34 112 81 0.11 112 83 0.16 0.32 0.24 0.17 0.24 112 85 0.50 0.25 0.36 0.29 112 87 0.19 0.19 0.40 0.23 112 89 0.22 0.30 0.16 0.17 0.12 0.21 112 91 0.23 0.22 0.41 0.28 0.16 0.18 112 93 0.26 0.17 112 95 0.17 0.17 0.19 0.13 0.52 0.23 112 97 0.37 0.43 0.29 0.12 112 99 0.19 0.24 0.32 0.48 0.20 112 101 0.49 0.45 0.20 112 103 0.19 0.15 112 105 0.14 113 42 0.15 113 48 0.16 0.21 0.15 113 68 0.25 0.30 113 74 0.13 113 84 0.25 0.18 0.22 113 86 0.51 0.51 0.30 0.25 0.18 113 88 0.39 0.42 0.15 0.15 113 90 0.13 0.34 0.32 0.39 0.12 0.17 113 92 0.15 0.15 0.18 0.13 0.16 DEG CHN 123 P2 150 P2 93 P2 134 P2 105 P2 119 P2 112 P2 119 P2 122 P2 130 P2 123 P2 94 P2 102 P2 102 P2 89 P2 125 P2 110 P2 93 P2 63 P2 100 P2 125 P2 118 P2 119 P2 119 P2 99 P2 79 P2 129 P2 123 P2 112 P2 140 P2 141 P2 129 P2 126 P2 129 P2 122 P2 129 P2 126 P2 131 P2 147 P2 124 P2 139 P2 133 P2 127 P2 134 P2 119 P2 122 P2 110 P2 135 P2 148 P2 123 P2 114 P2 139 P2 127 P2 137 P2 104 P2 109 P2 110 P2 82 P2 124 P2 97 P2 107 P2 110 P2 73 P2 75 P2 92 P2 113 P2 108 P2 92 P2 103 P2 139 P2 123 P2 126 P2 118 P2 128 P2 92 P2 130 P2 121 P2 127 P2 135 P2 137 P2 IND %TW TWD 13 TWD 5 TWD 7 TWD 12 TWD 10 TWD 7 TWD 9 TWD 17 TWD 10 TWD 14 TWD 12 TWD 7 TWD 7 TWD 13 TWD 9 TWD 8 TWD 10 TWD 6 TWD 6 TWD 5 TWD 8 TWD 9 TWD 8 TWD 13 TWD 10 TWD 6 TWD 7 TWD 9 TWD 6 TWD 6 TWD 6 TWD 7 TWD 5 TWD 16 TWD 8 TWD 12 TWD 14 TWD 10 TWD 5 TWD 7 TWD 9 TWD 11 TWD 15 TWD 7 TWD 15 TWD 14 TWD 7 TWD 7 TWD 6 TWD 5 TWD 6 TWD 6 TWD 8 TWD 6 TWD 12 TWD 14 TWD 7 TWD 12 TWD 9

TWD 10 TWD 16 TWD 16 TWD 11 TWD 9 TWD 7 TWD 13 TWD 14 TWD 6

TWD 6

TWD 5

TWD 11 TWD 11 TWD 13 TWD 5 TWD 6

TWD 6

TWD 6

TWD 7 TWD 5

TWD 6

LOCATION AV4

+0.00 AV4

+0.00 AVI

+0.00 AV2

+0.00 AV6

+0.00 AV7

+0.00 AV8

+0.00 AVI

+0.02 AV3

+0.09 AV4

+0.00 AV6

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV3

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV7

+0.00 AV5

-0.07 AV4

-0.07 AV3

+0.02 AV2

+0.02 AVi

-0.02 AV2

-0.05 AVi

+0.21 AV7

-0.05 AV6

-0.09 AV5

-0.09 AV4

-0.12 AV3

+0.07 AV2

-0.18 AV5

-0.07 AV4

-0.16 AV3

-0.09 AV2

-0.21 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV7

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.09 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV2

+0.12 AV3

+0.09 AV6

+0.05 AV2

+0.00 AV3

+0.00 AV8

+0.00 AV8

+0.00 AV5

+0.00 AV4

+0.00 AV2

+0.00 AVI

+0.00 AV6

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV8

+0.00 AV7

-0.05 AV6

-0.09 AV5

+0.02 AV4

-0.05 AV3

+0.00 AV7

+0.00 AV6

+0.00 AV5

-0.11 AV4

-0.23 AV3

-0.14 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL 8

6 6

6 6

6 6

4 4

4 4

15 15 15 15 16 16 16 16 16 16 16 16 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 12 13 11 11 11 9

9 9

7 7

7 15 15 15 15 15 16 16 16 16 16 16 16 16 16 16 14 14 14 14 14

  1. LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT NOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT NOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:36 Component: S/G B Page 38 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 38 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.15 113 94 0.31 0.45 0.39 0.15 0.16 113 96 0.16 0.15 0.39 0.43 0.29 113 98 0.22 0.19 113 100 0.21 0.22 114 41 0.12 0.25 114 43 0.11 0.18 0.11 114 67 0.10 0.15 0.25 0.14 0.18 114 73 0.12 114 75 0.21 0.20 0.18 114 77 0.12 114 79 0.14 114 81 0.12 114 83 0.18 0.49 0.31 114 87 0.42 0.67 0.70 0.46 0.29 114 89 0.11 0.35 0.26 0.12 0.18 0.27 0.19 114 91 0.20 0.25 0.14 0.44 0.30 114 93 0.11 0.11 114 95 0.12 0.29 0.27 0.35 114 97 0.17 114 99 0.27 0.66 0.48 0.23 114 101 0.39 0.34 0.25 114 103 0.10 0.16 115 40 0.12 0.16 115 56 0.14 115 58 0.16 115 60 0.11 115 70 0.17 115 72 0.17 0.15 115 74 0.22 0.13 0.13 0.13 DEG CHN 147 P2 130 P2 114 P2 123 P2.

123 P2 124 P2 130 P2 145 P2 121 P2 121 P2 116 P2 128 P2 136 P2 122 P2 136 P2 137 P2 113 P2 97 P2 141 P2 135 P2 135 P2 137 P2 107 P2 97 P2 128 P2 119 P2 121 P2 90 P2 107 P2 107 P2 124 P2 61 P2 69 P2 101 P2 122 P2 100 P2 107 P2 116 P2 114 P2 89 P2 119 P2 106 P2 86 P2 64 P2 88 P2 91 P2 93 P2 129 P2 94 P2 66 P2 112 P2 89 P2 110 P2 69 P2 125 P2 96 P2 108 P2 123 P2 110 P2 128 P2 122 P2 116 P2 115 P2 118 P2 109 P2 116 P2 76 P2 126 P2 143 P2 132 P2 144 P2 148 P2 127 P2 108 P2 139 P2 145 P2 118 P2 98 P2 103 P2 104 P2 IND %TW LOCATION TWD 6 AV2 TWD 11 AVS TWD 14 AV4 TWD 13 AV3 TWD 6 AV2 TWD 6 AV7 TWD 6 AV6 TWD 6 AV5 TWD 13 AV4 TWD 14 AV3 TWD 10 AV2 TWD 8 AV3 TWD 7 AV2

+

TWD 8 AV6

+

TWD 8 AV2

+

TWD 6 AV4

+

TWD 11 AV3

+

TWD 5 AV7 TWD 7 AV5

+

TWD 5 AV2

+

TWD 5 AV6 H

TWD 7 AV5

+

TWD 10 AV3 H

TWD 6 AV2

+

TWD 8 AV4

+

TWD 7 AV2

+

TWD 10 AVI

+

TWD 10 AV2

+

TWD 9 AV3

+

TWD 6 AV4

+

TWD 7 AV6

+

TWD 6 AV4

+

TWD 9 AV3 H

TWD 19 AV4 H

TWD 14 AV7 H

TWD 14 AV7

+

TWD 19 AV6

+

TWD 19 AV4 H

TWD 15 AV2

+

TWO 10 AVI

+

TWD 5 AV8

+

TWD 12 AV7

+

TWD 10 AV6

+

TWD 5 AVS

+

TWD 7 AV4

+

TWD 10 AV2

+

TWD 7 AVI

+

TWD 8 AV7

+

TWD 9 AV6

+

TWD 6 AV5

+

TWD 14 AV4

+

TWD 11 AV3

+

TWD 4 AV2

+

TWD 5 AV3

+

TWD 5 AV2

+

TWD 11 AV3

+

TWD 10 AV4

+

TWD 12 AV5

+

TWD 7 AV3

+

TWD 10 AV2

+

TWD 19 AV3

+

TWD 16 AV4

+

TWD 9 AV5

+

TWD 13 AV2

+

TWD 12 AV3

+

TWD 9 AV4

+

TWD 4 AV2

+

TWD 6 AV5

+

TWD 5 AV3 TWD 6 AV4

+

TWD 6 AV4

+

TWD 7 AV2

+

TWD 5 AV5

+

TWD 9 AV4

+

TWD 7 AVI

+

TWD 7 AV2

+

TWD 9 AV2

+

TWD 6 AV3

+

TWD 6 AV4

+

TWD 6 AVI

-0.32

-0.07

-0.12

-0.02

-0.14

-0.07

-0.05

-0.07

-0.16

+0.00

-0.07

+0.00

-0.00

-0.00

.000

.000 0.00 0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.07

-0.16

-0.00

-0.00

-0.00

-0.00

-0.00

  • 0.00

-0.00

  • 0.00

-0.00

-0.00

-0.00

-0.00

  • 0.00
  • 0.00
  • 0.00
  • 0.00
  • 0.00
  • 0.00
  • 0.00

-0.00

-0.00

  • 0.00
  • 0.00
  • 0.00
  • 0.00
  • 0.00
  • 0.00
  • 0.00
  • 0.00
  • 0.00
  • 0.00
  • 0.00
  • 0.00
  • 0.00
  • 0.00
  • 0.00 0.00
  • 0.00
  • 0.00 0.00
  • 0.51
  • 0.00 0.02 0.09
  • 0.00 0.05 0.21 0.09 0.00 0.00 0.00 0.09 0.00 0.02 EXT EXT TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC UTIL 1

UTIL 2

CAL # LEG 14 NOT 14 HOT 14 HOT 14 HOT 14 HOT 14 HOT 14 HOT 14 HOT 14 HOT 14 HOT 14 HOT 14 HOT 14 HOT 14 HOT 14 HOT 14 COLD 14 COLD 13 COLD 13 COLD 13 COLD 8

COLD 8

COLD 8

COLD 8

COLD 8

COLD 9

COLD 7

COLD 7

COLD 7

COLD 7

COLD 7

COLD 7

COLD 7

COLD 7

COLD 7

COLD 16 NOT 16 HOT 16 HOT 16 HOT 16 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 57 COLD 57 COLD 10 COLD 10 COLD 10 COLD 9

COLD 8

COLD 8

COLD 8

COLD 8

COLD 8

COLD 8

COLD PROBE 6=10UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 61OUL 610UL 619UL 610UL 610UL 61OUL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:36 Component:

S/G B Page 39 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes), Enc. 8 Page 39 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 QUERY: QueryMl ROW COL VOLTS 115 80 0.11 115 82 0.58 115 84 0.61 0.38 0.53 0.55 0.39 0.24 115 86 0.39 0.58 0.64 0.19 115 88 0.21 0.50 0.35 0.52 0.61 0.17 0.16 115 90 0.23 0.58 0.52 0.20 0.11 115 92 0.16 0.12 115 94 0.21 0.13 115 96 0.35 0.24 115 98 0.51 0.53 0.59 115 100 0.15 115 102 0.22 0.21 0.18 0.20 115 120 0.14 0.15 115 122 0.13 0.15 0.11 115 130 0.18 0.15 116 55 0.14 116 57 0.17 0.13 116 59 0.16 116 61 0.14 116 69 0.18 0.15 0.14 116 79 0.12 116 81 0.12 0.13 116 83 0.33 0.38 0.27 0.26 0.13 116 85 0.50 0.12 0.17 0.11 0.52 0.31 116 87 0.37 0.57 0.48 0.29 0.29 116 89 0.14 0.21 0.11 0.29 0.15 116 91 0.14 0.22 0.27 DEG CAN 136 P2 116 P2 108 P2 118 P2 101 P2 123 P2 123 P2 116 P2 118 P2 103 P2 111 P2 89 P2 91 P2 105 P2 100 P2 114 P2 114 P2 90 P2 68 P2 91 P2 105 P2 112 P2 87 P2 90 P2 114 P2 90 P2 117 P2 139 P2 126 P2 119 P2 119 P2 113 P2 121 P2 106 P2 128 P2 122 P2 119 P2 122 P2 113 P2 130 P2 113 P2 128 P2 144 P2 118. P2 117 P2 137 P2 117 P2 127 P2 134 P2 121 P2 68 P2 112 P2 71 P2 136 P2 118 P2 100 P2 107 P2 112 P2 127 P2 114 P2 136 P2 119 P2 112 P2 138 P2 144 P2 124 P2 120 P2 103 P2 102 P2 107 P2 79 P2 105 P2 49 P2 111 P2 138 P2 111 P2 110 P2 125 P2 117 P2 109 P2 IND %TW LOCATION TWD 5 AV5

+0.00 TWD 18 AV5

+0.00 TWD 19 AVI

+0.00 TWD 14 AV2

+0.00 TWD 17 AV3

+0.00 TWD 18 AV5

+0.00 TWD 14 AV6

+0.00 TWD 10 AV8

+0.00 TWD 13 AV8

+0.00 TWD 17 AV3

+0.00 TWD 18 AV2

+0.00 TWD 7 AVl

+0.00 TWD 8 AV8

+0.00 TWD 16 AV7

+0.00 TWD 12 AV6

+0.00 TWD 16 AV5

+0.00 TWD 18 AV4

+0.00 TWD 7 AV3

+0.00 TWD 6 AV2

+0.00 TWD 9 AV7

+0.00 TWD 17 AV6

+0.00 TWD 16 AV5

+0.00 TWD 8 AV3

+0.00 TWD 5 AV2

+0.00 TWD 6 AV2

+0.00 TWD 5 AV7

+0.23 TWD 8 AV3

+0.00 TWD 5 AV7

+0.00 TWD 12 AV3

+0.00 TWD 9 AV4

+0.00 TWD 16 AV2

+0.00 TWD 17 AV3

+0.00 TWD 18 AV4

+0.00 TWD 6 AV5

+0.00 TWD 8 AV2

+0.00 TWD 8 AV3

+0.00 TWD 7 AV4

+0.00 TWD 8 AV5

+0.00 TWD 5 AV4

+0.05 TWD 6 AV3

-0.23 TWD 5 AV4

+0.00 TWD 6 AV3

+0.00 TWD 4 AV2

+0.00 TWD 7 AV6

+0.00 TWD 6 AV5

-0.07 TWD 6 AV5

+0.00 TWD 7 AV5

+0.00 TWD 5 AV3

+0.07 TWD 7 AV5

+0.12 TWD 6 AVS

+0.00 TWD 9 AV2

+0.05 TWD 8 AV3

+0.05 TWD 8 AV5

+0.02 TWD 5 AV2

+0.00 TWD 5 AV3

+0.00 TWD 6 AV4

+0.00 TWD 12 AV2

+0.00 TWD 14 AV3

+0.00 TWD 11 AV5

+0.00 TWD 10 AV6

+0.00 TWD 5 AV8

+0.00 TWD 17 AVl

+0.05 TWD 5 AV3

+0.02 TWD 7 AV4

+0.00 TWD 5 AV6

+0.00 TWD 18 AV7

+0.05 TWD 12 AV8

+0.05 TWD 13 AV8

+0.00 TWD 17 AV5

+0.00 TWD 15 AV4

+0.00 TWD 10 AV3

+0.00 TWD 10 AV2

+0.00 TWD 5 AV7

+0.00 TWD 8 AV6

+0.00 TWD 4 AV5

+0.00 TWD 10 AV4

+0.00 TWD 6 AV2

-0.05 TWD 5 AV7

+0.00 TWD 8 AV6

+0.00 TWD 10 AV5

+0.00 EXT EXT TEH TEC TEA TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEN TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEH TEC TEN TEC TEN TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL 6

6 6

6 6

6 6

6 16 16 16 16 15 15 15 15 15 15 15 15 15 15 15 15 13 13 13 13 13 13 13 13 13 13 13 13 13 13 10 10 10 10 10 10 10 11 10 10 10 10 9

9 9

6 6

6 6

6 6

6 6

4 4

4 4

4 4

15 15 15 15 15 16 16 16 16 16 16 16 16

  1. LEG COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT NOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610TUL 610UL 610UL 610UL 6100L 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UDL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UDL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 610TDL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:36 Component: S/G B Page 40 of 48 Component: S/G B Page 40 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 40 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.17 0.17 116 93 0.34 0.36 0.14 116 95 0.47 0.32 0.16 116 97 0.26 0.12 117 78 0.12 0.10 117 82 0.13 117 84 0.47 0.13 0.14 0.50 117 86 0.35 0.58 0.59 0.47 0.15 0.15 117 88 0.19 0.17 0.18 0.20 117 90 0.18 0.27 0.38 0.19 117 92 0.15 0.15 0.22 0.20 0.27 117 94 0.20 117 98 0.13 0.21 0.15 0.16 117 100 0.22 0.22 0.31 118 83 0.13 0.16 0.39 0.30 118 85 0.19 0.24 118 87 0.15 0.12 0.37 0.46 0.42 118 89 0.15 0.38 0.38 0.14 118 91 0.17 0.16 0.34 0.44 0.39 0.16 118 93 0.14 0.24 0.32 0.14 118 95 0.25 0.11 0.32 0.14 118 97 0.45 118 99 0.16 118 127 0.13 119 78 0.12 0.13 119 82 0.20 0.54 DEG CHN 94 P2 106 P2 123 P2 127 P2 127 P2 132 P2 129 P2 144 P2 111 P2 144 P2 74 P2 85 P2 134 P2 104 P2 94 P2 60 P2 110 P2 107 P2 115 P2 102 P2 103 P2 94 P2 133 P2 117 P2 107 P2 67 P2 100 P2 107 P2 118 P2 116 P2 102 P2 137 P2 114 P2 130 P2 125 P2 133 P2 128 P2 131 P2 139 P2 134 P2 138 P2 138 P2 104 P2 130 P2 116 P2 114 P2 100 P2 92 P2 124 P2 122 P2 111 P2 137 P2 105 P2 102 P2 110 P2 76 P2 103 P2 107 P2 82 P2 95 P2 86 P2 115 P2 108 P2 117 P2 125 P2 117 P2 105 P2 101 P2 135 P2 115 P2 113 P2 124 P2 108 P2 116 P2 119 P2 79 P2 129 P2 134 P2 119 P2 115 P2 IND %TW TWO 7 TWD 7 TWD 11 TWD 12 TWD 5 TWD 15 TWD 11 TWD 6 TWD 9 TWD 5 TWD 6 TWD 5 TWD 7 TWD 18 TWD 7 TWD 7 TWD 19 TWD 12 TWD 18 TWD 18 TWD 15 TWD 6 TWD 6 TWD 7 TWD 7 TWD 7 TWD 7 TWD 7 TWD 10 TWD 13 TWD 7 TWD 6 TWD 6 TWD 8 TWD 7 TWD 9 TWD 7 TWD 5 TWD 8 TWD 6 TWD 6 TWD 8 TWD 8 TWD 11 TWD 7 TWD 8 TWD 16 TWD 13 TWD 8 TWD 10 TWD 6 TWD 5 TWD 12 TWD 15 TWD 14 TWD 6 TWD 13 TWD 13 TWD 6 TWD 7 TWD 6 TWD 12 TWD 14 TWD 13 TWD 6 TWD 6 TWD 9 TWD 11 TWD 6 TWD 9 TWD 5 TWD 12 TWD 6 TWD 15 TWD 6 TWD 5 TWD 5 TWD 6 TWD 8 TWD 17 LOCATION AV4

+0.00 AV3

+0.00 AV5

-0.07 AV4

-0.07 AV3

-0.02 AV5

+0.00 AV4

-0.16 AV2

-0.30 AV2

-0.25 AVl

+0.00 AV2

+0.00 AV3

+0.00 AV5

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV7

+0.00 AV8

+0.00 AV7

+0.00 AV6

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV6

+0.00 AV5

+0.00 AV3

+0.00 AV2

+0.00 AV8

-0.09 AV7

-0.05 AV6

-0.09 AV4

+0.05 AV7

+0.07 AV6

+0.07 AV5

-0.02 AV3

+0.02 AV2

+0.05 AV2

-0.09 AV6

+0.00 AV5

+0.00 AV3

+0.00 AV2

+0.00 AV5

+0.00 AV3

+0.00 AV2

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV7

+0.00 AVI

+0.05 AV6

+0.00 AV8

+0.00 AV7

+0.00 AV6

+0.00 AV3

+0.00 AV2

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.02 AV4

-0.02 AV5

+0.00 AV6

+0.00 AV7

-0.07 AV8

-0.02 AVI

+0.00 AV2

+0.00 AV6

+0.00 AV7

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV5

+0.00 AV4

+0.00 AV7

+0.00 AV4

+0.00 AV7

+0.00 AV3

+0.00 AV4

+0.00 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC UTIL 1

UTIL 2

CAL 16 16 14 14 14 14 14 14 14 14 7

7 7

7 7

7 7

15 15 15 15 15 15 16 16 16 16 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 7

7 7

7 4

4 16 16 16 16 16 15 15 15 15 15 15 15 15 15 15 13 13 13 13 13 13 13 13 13 13 10 6

6 6

6

  1. LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT NOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD PROBE 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL 61OUL 610UL 610UL 61OUL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 61OUL 610UL 61OUL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 61OUL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:36 Component: S/G B Page 41 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 41 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.37 0.18 0.13 119 84 0.24 0.32 0.38 0.18 119 88 0.18 0.29 0.65 0.15 0.21 0.29 119 90 0.32 0.31 0.32 0.15 0.12 119 92 0.19 0.15 119 94 0.14 119 124 0.16 120 83 0.26 0.34 0.37 0.12 0.12 120 85 0.13 0.13 0.34 120 87 0.35 0.51 0.47 0.41 120 89 0.15 0.15 0.19 0.16 0.21 0.13 120 91 0.24 0.35 0.49 0.52 0.36 120 93 0.20 0.14 120 97 0.19 0.16 120 105 0.13 121 58 0.13 0.15 121 74 0.09 0.11 0.14 121 82 0.23 0.16 121 84 0.13 0.48 0.26 0.27 121 86 0.22 0.50 121 88 0.14 0.48 0.52 0.41 0.23 0.19 0.16 0.12 121 90 0.25 0.41 0.34 0.26 0.36 0.11 121 92 0.33 0.18 0.24 DEG CHN 120 P2 117 P2 98 P2 111 P2 117 P2 124 P2 129 P2 92 P2 89 P2 108 P2 81 P2 77 P2 82 P2 91 P2 98 P2 119 P2 73 P2 58 P2 125 P2 69 P2 111 P2 115 P2 111 P2 121 P2 110 P2 129 P2 142 P2 127 P2 119 P2 125 P2 100 P2 95 P2 97 P2 111 P2 122 P2 116 P2 79 P2 105 P2 98 P2 131 P2 119 P2 107 P2 104 P2 114 P2 109 P2 124 P2 134 P2 142 P2 145 P2 139 P2 117 P2 138 P2 74 P2 55 P2 98 P2 94 P2 74 P2 44 P2 116 P2 119 P2 103 P2 80 P2 107 P2 114 P2 105 P2 107 P2 110 P2 112 P2 90 P2 99 P2 124 P2 106 P2 118 P2 110 P2 107 P2 116 P2 86 P2 122 P2 132 P2 130 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW 13 7

5 10 12 14 7

7 10 19 6

8 10 11 11 11 6

5 7

6 6

6 10 13 13 5

5 6

6 13 12 16 15 14 6

6 7

6 8

5 9

12 15 16 12 7

5 7

6 5

6 6

5 6

7 11 8

7 19 12 12 8

16 5

15 16 13 9

7 6

5 9

13 11 9

12 5

11 7

9 LOCATION AV6

+0.00 AV7

+0.00 AV8

+0.00 AVI

+0.00 AV3

+0.00 AV4

+0.00 AV6

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV3

+0.00 AVI

+0.00 AV5

+0.00 AV7

-0.25 AV2

+0.00 AV5

-0.09 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.09 AV2

+0.00 AV6

+0.02 AV8

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV8

+0.00 AV7

+0.00 AV6

+0,00 AV5

+0.00 AV4

+0.00 AV2

+0.00 AV8

+0.00 AV7

+0.02 AV6

+0.00 AV5

-0.02 AV2

-0.12 AV2

+0.02 AV3

+0.11 AV3

-0.23 AV2

-0.02 AV5

+0.00 AV6

+0.00 AV5

+0.00 AV2

+0.19 AV3

+0.25 AV4

+0.02 AV5

+0.00 AV6

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV7

+0.00 AV8

+0.00 AV3

+0.00 AV8

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

-0.18 AV2

-0.14 AVl

+0.00 AV8

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV3

+0.00 AV2

+0.00 AV7

+0.00 AV6

+0.00 AV3

+0.07 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL 6

6 6

6 6

6 6

15 15 15 15 15 15 15 15 15 15 15 13 13 13 10 6

6 6

6 6

4 4

4 15 15 15 15 16 16 16 16 16 16 16 16 16 16 16 14 14 14 14 12 10 10 9

9 9

7 7

7 7

7 7

15 15 16 16 16 16 16 16 16 16 16 16 16 16 16 16 14 14 14

  1. LEG COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT NOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT NOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:36 Component: S/G B Page 42 of 48 Component: S/C B Page 42 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 42 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.20 0.17 121 94 0.23 0.26 121 100 0.41 0.14 121 102 0.18 0.17 0.16 122 83 0.28 0.36 0.17 122 85 0.57 122 87 0.20 0.15 0.64 0.29 122 89 0.15 0.30 0.49 0.14 0.12 122 91 0.13 0.20 0.49 0.18 0.17 0.13 122 93 0.21 0.17 0.15 122 95 0.21 0.21 122 99 0.13 0.24 122 103 0.16 0.18 123 70 0.21 123 72 0.12 123 74 0.10 0.11 123 78 0.13 0.10 123 82 0.20 123 84 0.12 0.15 123 86 0.27 0.28 0.46 0.19 123 88 0.24 0.38 0.21 0.20 0.16 0.19 123 90 0.23 0.21 0.22 123 92 0.14 0.14 0.12 123 94 0.15 0.42 0.15 0.15 123 98 0.23 0.20 0.22 0.17 123 104 0.09 124 55 0.12 124 69 0.12 124 83 0.24 0.41 0.45 0.24 124 85 0.25 0.49 124 87 0.18 DEG CHN 129 P2 147 P2 117 P2 120 P2 136 P2 140 P2 131 P2 124 P2 133 P2 92 P2 107 P2 82 P2 119 P2 118 P2 104 P2 105 P2 104 P2 69 P2 106 P2 98 P2 51 P2 63 P2 11 P2 68 P2 112 P2 112 P2 124 P2 107 P2 119 P2 98 P2 79 P2 109 P2 119 P2 86 P2 108 P2 114 P2 134 P2 130 P2 135 P2 125 P2 142 P2 96 P2 116 P2 124 P2 142 P2 105 P2 92 P2 93 P2 I11 P2 123 P2 73 P2 98 P2 72 P2 100 P2 74 P2 85 P2 105 P2 95 P2 77 P2 72 P2 53 P2 133 P2 130 P2 118 P2 130 P2 124 P2 104 P2 125 P2 112 P2 110 P2 139 P2 139 P2 116 P2 105 P2 123 P2 122 P2 111 P2 119 P2 120 P2 111 P2 IND %TW TWD 7 TWD 6 TWD 8 TWD 9 TWD 13 TWD 5 TWD 7 TWD 6 TWD 6 TWD 13 TWD 15 TWD 9 TWD 19 TWD 8 TWD 6 TWD 18 TWD 10 TWD 6 TWD 11 TWD 16 TWD 6 TWD 5 TWD 5 TWD 8 TWD 16 TWD 7 TWD 7 TWD 5 TWD 8 TWD 7 TWD 6 TWD 8 TWD 8 TWD 5 TWD 9 TWD 6 TWD 7 TWD 9 TWD 5 TWD 5 TWD 5 TWO 5 TWD 5 TWD 8 TWD 5 TWD 6 TWD 10 TWD 10 TWD 15 TWD 7 TWD 9 TWD 13 TWD 8 TWD 8 TWD 6 TWD 7 TWD 9 TWD 8 TWD 8 TWD 6 TWD 6 TWD 5 TWD 6 TWD 14 TWD 6 TWD 6 TWD 9 TWD 8 TWD 9 TWD 7 TWD 4 TWO 5 TWD 7 TWD 9 TWD 14 TWD 15 TWD 10 TWD 10 TWD 17 TWD 7 LOCATION AV2 AVI AV4 AV3 AV5 AV2 AV5 AV4 AVI AV2 AV5 AVI AV2 AV8 AV7 AV3 AV2 AV6 AV5 AV4 AV3 AV2 AVI AV2 AV5 AV6 AV7 AV8 AV2 AVS AV7 AV2 AV3 AV2 AV7 AV3 AV4 AV4 AV3 AV3 AV7 AV3 AV4 AV6 AV3 AV8 AV6 AV4 AV3 AV2 AV8 AV7 AV6 AV5 AV3 AV2 AV7 AV6 AV3 AV6 AV7 AV2 AV2 AV4 AV5 AV3 AV2 AV3 AV4 AV6 AV3 AV4 AV5 AV3 AV4 AV5 AV6 AV2 AV8 AV7

-0.18

+0.09

-0.11

+0.07

-0.07

[0.00

-0.07

-0.09

+0.00

+0.00

+0.00

+0.00

+0.07

+0.00

+0.00

+0.00

-0.46

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.23

+0.07

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.19

-0.02

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.07

-0.05

+0.00

+0.00

+0.00

+0.00

+0.00

+0.05

+0.00 EXT EXT TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEN TEC TEH TEC TEH TEC TEH TEC TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEE TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH UTIL 1

UTIL 2

CAL # LEG 14 HOT 14 HOT 14 HOT 14 HOT 14 HOT 14 HOT 14 HOT 14 HOT 14 HOT 7

COLD 7

COLD 7

COLD 4

COLD 16 HOT 16 HOT 16 HOT 16 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 8

COLD 8

COLD 8

COLD 8

COLD 6

COLD 6

COLD 6

COLD 6

COLD 6

COLD 16 HOT 16 HOT 16 HOT 16 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 15 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 13 HOT 11 COLD 9

COLD 6

COLD 6

COLD 6

COLD 6

COLD 4

COLD 4

COLD 15 HOT PROBE 610UL 610OL 610OL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610OL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TDL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610OL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610DL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:37 Component: S/G B Page 43 of 48 Component: S/S B Page 43 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 43 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.21 0.41 0.29 124 89 0.34 0.22 0.12 0.11 124 91 0.60 0.44 0.36 0.11 124 93 0.23 0.15 0.18 0.15 124 95 0.15 0.18 125 54 0.13 0.12 125

56.

0.15 125 62 0.13 125 68 0.18 0.17 125 72 0.14 0.16 125 82 0.18 0.13 0.17 125 84 0.30 0.47 0.14 125 88 0.14 0.36 0.14 125 90 0.29 0.42 0.28 0.27 0.14 0.11 125 92 0.16 125 94 0.18 0.13 0.20 125 96 0.40 0.33 0.30 125 98 0.15 0.27 0.14 125 100 0.22 0.15 125 102 0.67 0.31 0.21 126 55 0.23 0.16 0.16 126 69 0.12 126 83 0.23 0.33 126 87 0.42 0.21 0.21 0.34 0.16 0.19 126 89 0.38 0.28 126 91 0.17 0.28 126 93 0.18 0.10 126 95 0.14 126 101 0.14 126 103 0.24 126 119 0.18 127 66 0.12 127 68 0.21 0.17 DEG 102 108 100 116 108 80 81 116 110 106 83 140 144 130 141 142 117 133 140 136 120 74 93 65 88 99 82 108 88 109 82 103 113 108 120 114 112 ill 84 125 133 136 127 124 131 125 126 120 117 142 128 146 120 121 139 127 110 83 132 91 112 110 98 92 ill 112 113 90 97 125 100 99 125 106 108 129 107 124 132 102 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW LOCATION TWD 8 AV3

+

TWD 14 AV2 TWD 10 AVI TWD 12 AV6

+

TWD 8 AV5

+

TWD 5 AV3 TWD 4 AV2

+

TWD 18 AV7

+

TWD 14 AV6

+

TWD 12 AV5

+

TWD 5

AV2

+

TWD 8

AV4 TWD 6 AV3 TWD 7 AV2 TWD 6 AVI TWD 6 AV3

+

TWD 7 AV2

+

TWD 6 AV3

+

TWD 5 AV6

+

TWD 6 AV2

+

TWD 6 AV5 TWD 9 AV4

+

TWD 9 AV5 TWD 7 AV2 TWD 8 AV4

+

TWD 9 AV4

+

TWD 7 AV6

+

TWD 9 AV7

+

TWD 13 AV3 A

TWD 18 AV5 4

TWD 7 AV6

+

TWD 5 AV8

+

TWD 12 AV6 4

TWD 5 AV2 TWD 10 AV7 4

TWD 14 AV6

+

TWD 10 AV5 4

TWD 10 AV4

+

TWD 5 AV2 4

TWD 5 AVI

+

TWD 6 AV7 TWD 7 AV2

+

TWD 5 AV3 TWD 7 AV5 TWD 13 AV4 TWD 11 AV3

+

TWD 10 AVI

+

TWD 6 AV5

+

TWD 9 AV4 4

TWD 5 AV3 4

TWD 8 AV5

+

TWD 6 AV4

+

TWD 19 AV4

+

TWD 11 AV3

+

TWD 8 AV2

+

TWD 9 AV5

+

TWD 7 AV6 TWD 7 AV7 TWD 5 AV4

+

TWD 11 AV4

+

TWD 14 AV5

+

TWD 14 AV7

+

TWD 8 AV6

+

TWD 8 AV5

+

TWD 12 AV4

+

TWD 6 AV3

+

TWD 7 AV2 TWD 13 AV6

+

TWD 10 AV5

+

TWD 7 AV7

+

TWD 10 AV5

+

TWD 7 AV2

+

TWD 4 AV6

+

TWD 6 AV5

+

TWD 6 AV3

+

TWD 9 AV5

+

TWD 7 AV4

+

TWD 5 AV6

+

TWD 9 AV3

+

TWD 7 AV2

+

0.00 0O.00 0.00

-0.00

-0.00 0.032

-0.00

-0.00

-0.00

-0.00

-0.00

-0.07

-0.02

-0.09

-0.16

-0.00

-0.11

-0.00

-0.00

-0.12

-0.51

-0.00

-0.02?

-0.16

-0. 21

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.21

-0.00

-0.00

-0.00

-0.00

-0.05

-0.00

-0.02

-0.00

-0.09

-0.02

-0.07

-0.05

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.02

-0.02

-0.05

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00 0.12

-0.00

-0.00 0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00

-0.00 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC UTIL 1

UTIL 2

CAL 15 15 15 16 16 16 16 16 16 16 16 14 14 14 14 14 14 11 11 10 8

9 9

9 9

7 7

7 7

7 7

16 16 16 16 16 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 58 58 58 8

7 7

16 16 16 16 16 16 15 15 15 15 13 13 13 13 13 10 8

8 8

LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD PROBE 610UL 610UL 610UL 610UL 610UL 610UL 6100L 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl 12/18/12 14:59:37 Component: S/G B Page 44 of 48, Enc. 8 Page 44 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev, 0 ROW COL VOLTS 127 74 0.21 0.12 127 82 0.13 0.14 127 84 0.42 0.51 0.22 0.38 0.33 0.57 127 86 0.31 0.37 0.41 0.15 127 88 0.16 0.26 0.21 127 90 0.16 0.24 0.15 0.35 0.13 0.28 127 92 0.10 0.10 127 98 0.15 127 102 0.22

0. 12 0.16 0.14 128 53 0.47 0.46 0.09 128 67 0.16 0.16 128 71 0.20 128 77 0.11 128 79 0.12 128 81 0.18 128 83 0.19 0.13 0.12 0.17 0.15 128 85 0.21 0.27 128 87 0.23 0.16 128 89 0.14 0.12 128 91 0.27 0.28 0.20 0.22 0.20 0.19 128 97 0.19 0.19 0.17 0.25 128 101 0.15 0.15 0.14 128 103 0.45 0.47 0.35 0.15 128 107 0.14 128 111 0.16 128 117 0.12 0.28 0.18 0.15 0.28 129 68 0.24 129 74 0.16 129 78 0.19 129 80 0.14 129 82 0.16 129 84 0.48 DEG 126 86 92 134 126 127 108 112 107 104 122 105 118 104 90 114 117 71 83 108 104 125 88 119 77 118 109 101 98 118 119 126 79 122 93 103 142 115 124 119 76 121 128 125 126 107 120 67 104 114 131 ill 99 99 103 97 140 134 138 126 130 120 137 131 132 125 103 127 109 140 121 112 107 119 74 80 76 58 47 108 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWD 9 TWD 5 TWD 6 TWD 6 TWD 15 TWD 17 TWD 9 TWD 14 TWD 12 TWD 18 TWD 11 TWD 12 TWD 13 TWD 6 TWD 6 TWD 9 TWD 8 TWD 6 TWD 9 TWD 6 TWD 12 TWD 5 TWD 10 TWD 4 TWD 4 TWD 6 TWD 9 TWD 5 TWD 7 TWD 6 TWD 16 TWD 15 TWD 4 TWD 8 TWD 8 TWD 8 TWD 5 TWD 5 TWD 7 TWD 8 TWD 5 TWD 5 TWD 7 TWD 6 TWD 9 TWD 11 TWD 9 TWD 6 TWD 5 TWD 5 TWD 10 TWD 10 TWD 8 TWD 8 TWD 7 TWD 7 TWD 7 TWD 7 TWD 6 TWD 9 TWD 6 TWD 6 TWD 5 TWD 14 TWD 15 TWD 12 TWD 6 TWD 5 TWD 6 TWD 5 TWD 10 TWD 7 TWD 6 TWD 10 TWD 12 TWD 8 TWD 9 TWD 7 TWD 8 TWD 19 LOCATION AV3

+0.09 AV6

-0.16 AV4

+0.00 AV7

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV6

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV7

+0.00 AV6

+0.00 AV2

+0.00 AV8

+0.00 AV7

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AVI

+0.00 AV3

+0.00 AV7

+0.00 AV3

+0.00 AV2

+0.00 AV3

+0.00 AV4

+0.00 AV5

-0.09 AV5

+0.00 AV4

+0.00 AV7

+0.30 AV5

+0.14 AV6

-0.14 AV4

+0.05 AV3

+0.00 AV2

+0.00 AV4

+0.00 AV3

+0.00 AV4

+0.00 AV5

+0.00 AV6

+0.00 AV7

+0.00 AV6

+0.02 AV2

+0.00 AV6

+0.00 AV5

+0.00 AV7

+0.00 AV6

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

-0.23 AV2

-0.28 AV5

-0.07 AV4

-0.12 AV3

+0.09 AV2

-0.05 AV7

+0.00 AV4

+0.00 AV2

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV5

+0.00 AV7

+0.00 AV3

+0.00 AV8

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV2

+0.02 AV6

+0.00 AV6

+0.00 AV4

+0.00 AV4

+0.00 AV3

+0.00 EXT EXT TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC UTIL 1

UTIL 2

CAL #

8 8

6 6

6 6

6 6

6 6

16 16 16 16 15 15 15 15 15 15 15 15 15 13 13 13 13 13 13 13 11 11 11 9

9 8

6 6

6 6

6 6

6 6

4 4

15 15 16 16 16 16 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 12 11 12 12 12 12 12 9

9 7

7 7

7 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD NOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD NOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT NOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD PROBE 610UL 610UL 6 10 DL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610OL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TDL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610OUL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:37 Component: S/G B Page 45 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 45 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.36 0.26 129 86 0.51 0.35 129 88 0.17 0.19 0.19 0.16 129 90 0.39 0.21 0.35 0.53 0.30 129 92 0.21 0.15 0.17 0.20 0.12 129 94 0.21 0.23 0.18 129 96 0.17 0.16 0.14 129 100 0.13 0.15 129 102 0.18 0.31 0.22 129 112 0.18 0.11 130 67 0.35 0.32 130 69 0.18 130 83 0.13 130 85 0.24 0.19 130 87 0.14 0.27 0.37 130 89 0.23 0.33 0.44 0.27 130 91 0.22 0.39 0.29 130 93 0.28 130 95 0.18 0.11 0.13 0.14 130 97 0.10 0.25 130 103 0.30 0.30 0.20 0.13 131 68 0.27 131 70 0.14 0.13 0.22 131 74 0.13 0.11 131 78 0.11 131 82 0.13 0.31 131 84 0.08 0.15 131 86 0.27 0.57 0.41 0.22 0.11 131 88 0.15 0.27 0.17 131 90 0.68 0.21 0.18 DEG CHN 113 P2 111 P2 102 P2 103 P2 117 P2 119 P2 72 P2 136 P2 99 P2 118 P2 100 P2 108 P2 122 P2 129 P2 137 P2 103 P2 138 P2 122 P2 127 P2 121 P2 141 P2 135 P2 120 P2 147 P2 135 P2 127 P2 138 P2 121 P2 121 P2 124 P2 129 P2 123 P2 120 P2 108 P2 113 P2 117 P2 126 P2 92 P2 128 P2 116 P2 74 P2 89 P2 96 P2 102 P2 80 P2 103 P2 82 P2 126 P2 118 P2 143 P2 101 P2 126 P2 79 P2 130 P2 129 P2 115 P2 134 P2 136 P2 126 P2 145 P2 137 P2 131 P2 128 P2 117 P2 57 P2 90 P2 98 P2 99 P2 105 P2 106 P2 112 P2 118 P2 97 P2 86 P2 67 P2 98 P2 59 P2 113 P2 77 P2 103 P2 IND %TW TWD 15 TWD 12 TWD 16 TWD 12 TWD 7 TWD 7 TWD 7 TWD 6 TWD 13 TWD 8 TWD 12 TWD 16 TWD 10 TWD 8 TWD 6 TWD 6 TWD 7 TWD 5 TWD 8 TWD 8 TWD 7 TWD 6 TWD 6 TWD 5 TWD 5 TWD 6 TWD 7 TWD 11 TWD 8 TWD 7 TWD 5 TWD 13 TWD 12 TWD 8 TWD 7 TWD 10 TWD 8 TWD 5 TWD 10 TWD 12 TWD 9 TWD 12 TWD 14 TWD 10 TWD 8 TWD 13 TWD 10 TWD 11 TWD 7 TWD 5 TWD 5 TWD 6 TWD 4 TWD 9 TWD 11 TWD 11 TWD 8 TWD 5 TWD 11 TWD 6 TWD 6 TWD 9 TWD 6 TWD 5 TWD 5 TWD 6 TWD 12 TWD 4 TWD 6 TWD 10 TWD 17 TWD 13 TWD 8 TWD 5 TWD 6 TWD 10 TWD 7 TWD 19 TWD 8 TWD 7 LOCATION AV4 AV7 AV7 AV5 AV7 AV5 AV4 AV2 AV7 AV6 AV5 AV4 AV3 AV7 AV5 AV3 AV2 AV6 AV4 AV3 AV2 AV7 AV5 AV4 AV2 AVI AV5 AV3 AV2 AV6 AV4 AV6 AV5 AV5 AV3 AV2 AV4 AV7 AV6 AV5 AV6 AV5 AV4 AV2 AV2 AV5 AV6 AV2 AV4 AV6 AV7 AV8 AV2 1

AV4 AV2 AV3 1

AV4

+

AV7

+

AV4

+

AV8

+

AV6 1

AV5 AV2 1

AV4

+

AV6 AV3 1

AV4

+

AV2

+

AV6 1

AV8 AV5 1

AV3 1

AV2 1

AVI AV7

+

AV6'

+

AV5

+

AV4

+

AV3

+

AV2

+

+-0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

-0.16

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

-0.12

+0.21

-0.02

+0.00

+0.02

-0.12

-0.09

-0.09

-0.05

+0.00

+0.00

+0.00

+0.00

+0.00

+0.02

-0.12

+0.00

'0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00 r0.00

+0.00

-0.07

-0.02

+0.00

+0.00

+0.00

÷0.00 r0.00

+0.00 r0.00 r0.00

+0.00 r0.00 0.00 0.00 0.00 0.09

+0.00 0.21 0.07 0.00 10.00

+0.00

0. 00 0.00 10.00 10.00 10.00 0.00

-0.18 0.00 0.00 0.00 10.00 10.00 0.00 EXT EXT TEN TEC TEH TEC TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL 7

7 15 15 16 16 16 16 16 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 12 12 8

8 8

7 4

4 16 16 16 15 15 15 15 15 15 15 13 13 13 13 13 13 13 13 13 13 13 8

8 8

8 8

8 6

6 6

6 6

16 16 16 16 16 15 15 15 15 15 15

  1. LEG COLD COLD NOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD NOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD NOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610OL 610UL 610TUL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 6100L 610UL 610UL 610UL 610UL 610UL 610OL 610UL 610UL 610UL 610OL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 6100L 610UL 610UL 610UL 610UL 61OUL 61CUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610OL 61OUL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:37 Component: S/G B Page 46 of 48 Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 46 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.43 131 92 0.20 0.18 131 94 0.14 0.20 131 98 0.20 0.15 131 102 0.15 0.23 0.48 0.16 131 104 0.14 0.15 0.33 132 67 0.14 0.43 0.19 132 69 0.09 0.15 132 71 0.50 0.16 132 73 0.19 132 75 0.11 0.12 132 77 0.31 132 79 0.13 132 81 0.14 132 83 0.10 132 85 0.18 0.13 132 89 0.11 0.15 0.12 0.34 0.13 132 91 0.12 0.13 0.56 0.26 0.12 132 93 0.19 0.18 0.16 0.15 132 95 0.17 0.18 0.20 0.18 132 101 0.28 0.19 0.18 132 103 0.16 0.17 0.41 0.49 0.22 133 68 0.23 0.20 133 70 0.13 0.30 0.16 133 72 0.22 133 74 0.26 133 78 0.19 133 82 0.16 133 86 0.15 0.09 133 88 0.14 0.19 0.24 133 90 0.27 0.42 0.59 0.64 0.25 0.25 0.11 133 92 0.48 0.27 0.17 DEG CHN 104 P2 124 P2 92 P2 139 P2 90 P2 107 P2 85 P2 124 P2 122 P2 112 P2 108 P2 114 P2 122 P2 116 P2 129 P2 117 P2 118 P2 59 P2 100 P2 123 P2 120 P2 126 P2 110 P2 145 P2 122 P2 124 P2 56 P2 119 P2 132 P2 148 P2 85 P2 136 P2 61 P2 106 P2 113 P2 96 P2 115 P2 127 P2 107 P2 106 P2 133 P2 134 P2 138 P2 123 P2 116 P2 128 P2 121 P2 135 P2 135 P2 134 P2 107 P2 115 P2 124 P2 122 P2 118 P2 133 P2 110 P2 99 P2 71 P2 93 P2 85 P2 117 P2 99 P2 72 P2 120 P2 67 P2 81 P2 122 P2 97 P2 123 P2 101 P2 117 P2 104 P2 110 P2 104 P2 122 P2 117 P2 115 P2 123 P2 122 P2 IND %TW TWD 14 TWD 8 TWD 7 TWD 6 TWD 8 TWD 8 TWD 6 TWD 6 TWD 9 TWD 16 TWD 7 TWD 6 TWD 6 TWD 12 TWD 7 TWD 18 TWD 10 TWD 5 TWD 8 TWD 17 TWD 7 TWD 8 TWD 5 TWD 5 TWD 12 TWD 6 TWD 7 TWD 5 TWD 8 TWD 6 TWD 4 TWD 6 TWD 5 TWD 12 TWD 5 TWD 5 TWD 5 TWD 17 TWD 9 TWD 5 TWD 7 TWD 7 TWD 6 TWD 6 TWD 6 TWD 7 TWD 7 TWD 7 TWD 10 TWD 7 TWD 7 TWD 6 TWD 6 TWD 13 TWD 15 TWD 8 TWD 11 TWD 10 TWD 7 TWD 14 TWD 8 TWD 11 TWD 12 TWD 9 TWD 8 TWD 6 TWD 4 TWD 5 TWD 7 TWD 9 TWD 10 TWD 14 TWD 17 TWD 18 TWD 9 TWD 9 TWD 4 TWD 15 TWD 10 TWD 6 LOCATION AVI

+0.00 AV6

+0.00 AV7

+0.00 AV2

+0.00 AV3

+0.00 AV3

+0.00 AV4

+0.00 AVI

+0.00 AV2

+0.00 AV4

+0.00 AV7

+0.00 AV3

+0.00 AV5

+0.00 AV6

+0.00 AV5

-0.05 AV6

+0.05 AV7

+0.00 AV5

+0.02 AV7

+0.16 AV6

+0.00 AV4

+0.00 AV5

+0.00 AV5

-0.14 AV2

+0.07 AV6

+0.00 AV4

+0.00 AV4

+0.00 AV7

+0.00 AV3

+0.00 AV5

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

-0.12 AV3

-0.16 AV5

-0.09 AV6

-0.12 AV7

-0.19 AV4

-0.21 AV7

-0.12 AV6

-0.12 AV5

-0.19 AV6

-0.12 AV5

-0.12 AV4

-0.14 AV3

-0.37 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV7

-0.05 AV5

-0.21 AV4

-0.12 AV3

+0.00 AV2

+0.00 AV4

+0.00 AV8

+0.05 AV5

-0.19 AV6

+0.02 AV7

+0.09 AV5

-0.07 AV5

+0.00 AV6

+0.00 AV6

+0.00 AV6

+0.00 AV3

+0.00 AV6

+0.00 AV5

+0.00 AV2

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

-0.16 AV2

-0.28 AVI

+0.00 AV7

+0.00 AVS

-0.05 AV4

-0.09 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL 15 13 13 13 13 13 13 13 13 13 13 13 13 13 9

9 9

9 9

8 8

8 8

8 6

6 7

6 4

4 16 16 16 16 16 16 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 9

9 9

9 9

9 9

7 7

15 15 16 16 16 16 16 16 16 16 16 16 14 14 14

  1. LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TDL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement Bobbin AVB Wear Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl 12/18/12 14:59:37 Component: S/G B Page 47 of 48, Enc. 8 Page 47 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 0.16 133 96 0.19 0.19 0.17 0.17 133 100 0.15 133 102 0.27 0.16 0.20 0.57 0.15 134 71 0.16 0.42 0.18 134 73 0.12 0.18 0.15 134 75 0.14 134 77 0.23 134 79 0.20 0.17 134 81 0.16 134 83 0.21 134 87 0.13 134 89 0.13 0.22 0.28 0.28 0.17 0.16 134 91 0.17 0.18 0.55 0.51 0.13 134 93 0.21 134 95 0.18 134 103 0.33 0.25 0.47 0.27 0.12 0.16 135 76 0.18 0.15 135 80 0.15 0.14 135 82 0.21 0.45 0.66 0.39 0.18 135 84 0.24 0.27 135 86 0.18 0.14 0.28 0.22 135 90 0.34 0.37 0.19

0. 17 0.13 135 92 0.64 0.12 0.37 0.09 135 94 0.16 0.17 0.17 135 96 0.27 0.29 136 73 0.15 136 83 0.65 0.27 0.11 136 87 0.23 0.22 0.48 0.68 DEG CHN 135 P2 108 P2 130 P2 135 P2 127 P2 134 P2 135 P2 140 P2 122 P2 122 P2 110 P2 113 P2 120 P2 135 P2 130 P2 95 P2 144 P2 151 P2 114 P2 120 P2 77 P2 83 P2 108 P2 107 P2 88 P2 119 P2 109 P2 102 P2 140 P2 88 P2 115 P2 130 P2 125 P2 128 P2 99 P2 125 P2 120 P2 113 P2 107 P2 125 P2 117 P2 106 P2 117 P2 137 P2 66 P2 138 P2 117 P2 128 P2 124 P2 120 P2 119 P2 126 P2 119 P2 111 P2 145 P2 92 P2 131 P2 110 P2 125 P2 133 P2 127 P2 101 P2 133 P2 115 P2 127 P2 122 P2 158 P2 130 P2 126 P2 114 P2 118 P2 117 P2 127 P2 112 P2 97 P2 144 P2 115 P2 106 P2 121 P2 121 P2 IND %TW TWD 6 TWD 7 TWD 7 TWD 6 TWD 6 TWD 6 TWD 9 TWD 6 TWD 7 TWD 17 TWD 6 TWD 6 TWD 14 TWD 7 TWD 5 TWD 7 TWD 6 TWD 6 TWD 9 TWD 8 TWD 7 TWD 6 TWD 8 TWD 5 TWD 5 TWD 8 TWD 10 TWD 10 TWD 7 TWD 6 TWD 7 TWD 7 TWD 17 TWD 16 TWD 5 TWD 8 TWD 7 TWD 12 TWD 9 TWD 16 TWD 10 TWD 5 TWD 6 TWD 7 TWD 6 TWD 6 TWD 6 TWD 8 TWD 15 TWD 19 TWD 13 TWD 7 TWD 9 TWD 10 TWD 7 TWD 5 TWD 10 TWD 8 TWD 12 TWD 13 TWD 7 TWD 7 TWD 5 TWD 19 TWD 5 TWD 13 TWD 4 TWD 6 TWD 7 TWD 7 TWD 10 TWD 11 TWD 6 TWD 19 TWD 10 TWD 5 TWD 9 TWD 8 TWD 15 TWD 19 LOCATION AV2

-0.28 AV7

-0.02 AV6

-0.07 AV3

+0.07 AV2

-0.23 AVI

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AVI

+0.00 AV8

-0.19 AV6

+0.12 AV5

+0.00 AV8

+0.00 AV7

+0.00 AV5

+0.00 AV8

+0.00 AV4

+0.00 AV6

+0.00 AV4

+0.00 AV4

-0.14 AV4

+0.00 AV5

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV3

+0.00 AV5

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AV7

+0.00 AV6

+0.00 AV6

+0.00 AV2

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV2

+0.00 AV6

+0.00 AV5

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV8

+0.00 AV7

+0.00 AV5

+0.00 AV3

+0.00 AV2

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV2

+0.00 AV6

+0.00 AV4

+0.00 AV3

+0.00 AV3

+0.00 AV2

+0.00 AV8

+0.00 AV6

+0.00 AV4

+0.00 AV3

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 EXT TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC EXT TEN TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEN TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH UTIL 1

UTIL 2

CAL #

14 14 14 14 14 14 14 14 14 14 14 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 32 32 32 32 32 32 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 32 31 31 31 31 31 31 31 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 61OUL 61OUL 61OUL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 61OUL 610UL 61OUL 61OUL 610UL 61OUL 61OUL 610UL 610UL 61OUL 610UL 61OUL 61OUL 610UL 610UL 61OUL 61OUL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 610UL 610UL 61OUL 61OUL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 14:59:38 Component: S/G B Page 48 of 48 Bobbin AVB Wearý Indications 1% to 19%

(Imperfect Tubes)

QUERY: QueryMl, Enc. 8 Page 48 of 48 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS 136 91 0.15 0.48 0.58 0.53 0.36 0.25 136 93 0.14 137 86 0.14 137 90 0.13 0.44 0.20 0.12 0.48 0.15 0.41 0.15 138 85 0.22 0.19 0.25 0.18 0.18 0.14 139 92 0.23 DEG 127 123 107 114 122 131 148 130 118 117 126 129 117 134 118 120 142 1il 119 95 123 140 123 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWD 6 TWD 15 TWD 18 TWD 17 TWD 13 TWD 9 TWD 6 TWD 6 TWD 5 TWD 15 TWD 8 TWD 5 TWD 16 TWD 6 TWD 14 TWD 6 TWD 8 TWD 8 TWD 9 TWD 7 TWD 7 TWD 6 TWD 9 LOCATION AV8

+0.00 AV6

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AVi

+0.00 AV4

+0.00 AV7

+0.00 AV8

+0.00 AV7

+0.00 AV6

+0.00 AV5

+0.00 AV4

+0.00 AV3

+0.00 AV2

+0.00 AVI

+0.00 AV8

+0.00 AV7

+0.00 AV5

+0.00 AV3

+0.00 AV2

+0.00 AVI

+0.00 AV7

+0.00 EXT EXT TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL #

31 31 31 31 31 31 31 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UL 610UL 610UL 610UL 610UL 610UL 610UL 6100L 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 61OUL 610UL 610UL 61OUL Total Tubes

1528 Total Records:

3782

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 15:13:50 Component: S/G B Compoent: /S BPage 1 of 1 Bobbin TSP Wear Indications 20% -

100%

(Degraded Tubes)

QUERY: QueryMi ROW COL VOLTS DEG CHN IND %TW LOCATION, Enc. 9 Page 1 of 1 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 Page 1 of 1

EXT EXT UTIL 1

UTIL 2

CAL # LEG PROBE Total Tubes

0 Total Records: 0

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 15:09:05 Component: S/G B Page 1 of 2 Bobbin TSP Wear Indications 1% -

19%

(Imperfect Tubes), Enc. 10 Page 1 of 2 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 QUERY: QueryMl ROW COL 1

32 1

56 1

70 1

82 1

84 1

116 1

148 1

154 1

168 2

2 2

2 2

2 2

3 3

10 11 20 22 34 36 39 42 44 45 54 55 61 61 66 67 68 74 75 77 78 86 86 93 104 106 109 116 117 118 120 121 121 122 123 123 124 125 127 128 129 130 130 130 131 133 133 134 134 134 134 135 135 136 137 7

21 63 69 75 159 169 3b 52 53 80 17 85 9

5 8

7 7

8 13 160 12 160 153 14 19 15 72 152 19 21 141 146 139 33 56 131 50 41 127 46 126 51 46 50 51 54 70 73 104 67 99 103 96 66 102 65 71 83 91 70 74 73 82 VOLTS 0.11 0.12 0.11 0.20 0.16 0.16 0.10 0.16 0.11 0.20 0.12 0.14 0.14 0.16 0.13 0.15 0.14 0.09 0.10 0.20 0.10 0.10 0.15 0.15 0.14 0.13 0.06 0.15 0.10 0.17 0.17 0.10 0.14 0.17 0.13 0.14 0.17 0.09 0.15 0.09 0.17 0.13 0.13 0.19 0.10 0.13 0.11 0.07 0.12 0.12 0.09 0.12 0.12 0.12 0.24 0.17 0.08 0.14 0.21 0.14 0.11 0.13 0.08 0.11 0.15 0.14 0.14 0.11 0.13 0.09 0.18 0.12 0.12 0.12 0.14 0.13 0.14 0.16 0.14 DEG 121 117 102 143 129 144 119 130 144 126 121 143 141 133 133 130 110 102 143 117 126 132 135 109 138 114 141 136 132 130 132 136 122 110 119 133 136 138 127 136 127 126 140 128 124 144 137 138 113 147 138 127 113 145 133 137 141 138 135 141 134 141 146 92 135 129 137 137 126 140 128 106 145 130 135 125 115 128 149 CHN P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 IND %TW TWD 8 TWD 8 TWD 8 TWD 13 TWD 10 TWD 10 TWD 7 TWD 10 TWD 7 TWD 12 TWD 8 TWD 11 TWD 9 TWD 10 TWD 9 TWD 10 TWD 9 TWD 7 TWD 7 TWD 13.

TWD 7 TWD 7 TWD 7 TWD 11 TWD 8 TWD 9 TWD 5 TWD 9 TWD 7 TWD 11 TWD 10 TWD 6 TWD 9 TWD 10 TWD 8 TWD 9 TWD 10 TWD 6 TWD 10 TWD 6 TWD 12 TWD 8 TWD 8 TWD 11 TWD 7 TWD 8 TWD 5 TWD 5 TWD 8 TWD 5 TWD 9 TWD 10 TWD 5 TWD 8 TWD 10 TWD 14 TWD 8 TWD 9 TWD 12 TWD 9 TWD 7 TWD 8 TWD 11 TWD 7 TWD 5 TWD 4 TWD 5 TWD 8 TWD 9 TWD 6 TWD 13 TWD 9 TWD 8 TWD 7 TWD 8 TWD 10 TWD 8 TWD 11 TWD 9 LOCATION 04C

-0.72 05C

-0.74 05C

-0.74 05C

+0.34 05C

-0.78 05C

+0.34 05C

-0.67 05C

-0.61 05C

+0.32 05C

-0.70 04C

+0.44 05H

-0.72 05C

+0.34 05C

-0.17 04C

-0.74 04C

-0.72 02C

+0.47 04C

+0.38 06C

+0.28 05C

+0.40 05C

-0.66 05C

-0.74 05H

+0.35 04C

+0.42 04H

+0.53 01C

-0.65 04C

-0.70 04C

-0.71 04C

-0.72 04C

-0.72 04C

-0.67 04C

-0.74 04C

-0.71 04H

-0.64 04C

-0.67 05C

+0.51 05C

+0.48 04C

-0.69 07C

-0.67 05C

-0.71 04H

-0.68 05C

+0.44 06C

+28.75 04H

+0.50 05C

+0.46 05H

-0.67 06C

-0.65 04H

-0.66 07C

-0.72 05C

-0.64 04H

-0.63 04H

-0.61 04C

+0.52 06C

+0.25 04C

-0.64 06C

-0.71 05C

-0.76 06C

-0.79 06C

-0.69 06C

-0.79 03C

-0.76 04H

+0.51 04C

-0.62 05C

+0.32 04C

-0.62 04H

-0.62 04C

-0.62 07C

-0.79 04H

+0.39 04H

-0.69 07H

+0.32 05C

+0.48 06C

+0.42 03C

-0.60 07C

+0.37 05C

+0.48 04H

+0.39 05C

+0.48 07C

+0.40 EXT EXT 07H TEC 07H TEC 07H TEC 07H TEC 07H TEC 07H TEC 07H TEC 07H TEC 07H TEC 07H TEC 07H TEC 07H TEH 07H TEC 07H TEC 07H TEC 07H TEC 07H TEC 07H TEC 07H TEC 07H TEC 07H TEC 07H TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEH TEC TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEH TEC TEH TEC TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC TEC TEH TEH TEC TEH TEC TEC TEH TEH TEC TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEH TEC TEC TEH TEC TEH TEC TEH TEH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH UTIL 1

UTIL 2

CAL 38 38 38 38 38 37 39 41 41 41 41 36 71 71 38 38 38 42 42 42 37 37 34 36 62 16 61 64 61 63 62 62 61 3

62 3

6 61 60 61 20 6

59 59 8

7 9

57 10 9

58 58 9

11 9

58 58 11 11 11 8

8 14 8

13 13 13 9

14 14 32 32 31 31 31 32 31 32 31

  1. LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT COLD HOT HOT COLD COLD COLD COLD HOT COLD COLD HOT HOT HOT COLD COLD HOT COLD COLD HOT COLD HOT COLD COLD COLD COLD COLD COLD COLD HOT COLD HOT HOT HOT COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 610UC 610UC 610UC 610UC 6100C 610UC 610UC 610UC 610UC 610UC 610UC 610UL 610UC 610UC 610OC 610UC 610UC 610UC 610UC 610UC 610OC 610UC 610UL 610UL 6100L 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610TUL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL 610UL

AREVA NP Inc Customer Name: St Lucie 2 Replacement 12/18/12 15:09:05 Component: S/G B Page 2 of 22 Bobbin TSP Wear Indications 1% -

19%

(Imperfect Tubes)

QUERY: QueryMl ROW COL VOLTS DEG 137 92 0.14 109 138 73 0.13 99 0.17 131 138 79 0.14 120 Total Tubes

76 Total Records:

83 CHN P3 P3 P3 P3 IND TWD TWD TWD TWD

%TW LOCATION 10 10 12 10 04C 05C 04H 05C

+0.51

+0.48

+0.44

+0.46 EXT TEC TEC TEC TEC EXT UTIL 1

UTIL 2

TEH TEH TEH TEH, Enc. 10 Page 2 of 2 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 CAL # LEG PROBE 32 HOT 61OUL 32 HOT 61OUL 32 HOT 61OUL 32 HOT 61OUL

AREVA NP Inc.

Customer Name: St. Lucie Unit 2 3/20/2013 6:49 AM Component: S/G B Page 1 of 1 Component: S/U B Page 1 of 1 09/12 -

EOC19 Bobbin WAR at VPAD, Enc. 11 Page 1 of 1 PSL-ENG-SESJ-12-006 Rev. 0 EC # 278014 Rev. 0 ROW COL VOLTS DEG CHN IND %TW LOCATION 73 156 NDD 0

0.30 108 0.30 115 0.30 115 2

2 P1 Pl NDD PTP CLP WAR DSI PID EXT EXT UTIL 1

UTIL 2

CAL # LEG PROBE TSC TSC 47 COLD 610PP TSH TSH 45 HOT 61OPP TEC TEH 5

HOT 610UL 0

AV6 AV6 0.23 0.21 52 COLD 5601P 0

AV6 AV6 31 27901.1 52 COLD 5601P 8

TEC TEH LAR VPAD 5

HOT 61OUL 8

TEC TEH MVOK 5

HOT 610LTL AV6

-1.7 AV6

-1.7 AV6

-1.6 AV6

-1.6 Total Tubes

1 Total Records:

7

AREVA NP Inc.

Customer Name: St. Lucie Unit 2 09/12 -

EOC19 Bobbin WAR at AV4 Locations on Row 69 3/20/2013 6:48 AM Component: S/G B Page 1 of 1 Aftacbment 1, Enc. 12 Page 1 of 1 PSL-ENG-SESJ-12-006 Rev. a EC #278014 Rev. 0 ROW COL VOLTS 69 20 0.20 69 98 0.16 Total Tubes

2 Total Records:

2 DEG CHN IND %TW 53 P5 TWD 7 83 P5 TWD 5 LOCATION AV4

+1.29 AV4

+1.33 EXT EXT UTIL 1

UTIL 2

CAL # LEG PROBE TEH TEC LAR 60 COLD 61OUL TEC TEH 26 HOT 61OUL