L-2007-076, Steam Generator Tube Inservice Inspection Special Report

From kanterella
Jump to navigation Jump to search
Steam Generator Tube Inservice Inspection Special Report
ML071350383
Person / Time
Site: Saint Lucie 
Issue date: 05/04/2007
From: Johnston G
Florida Power & Light Co
To:
Document Control Desk, NRC/NRR/ADRO
References
L-2007-076
Download: ML071350383 (93)


Text

0 FPL Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 May 4, 2007 L-2007-076 10 CFR 50.55a 10 CFR 50.36 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Re:

St. Lucie Unit 2 Docket No. 50-389 Refueling Outage SL2-16 Steam Generator Tube Inservice Inspection Special Report Attached is the Steam Generator Tube Inservice Inspection Special Report required by sections 4.4.5.5.b and 6.9.2 of the St. Lucie Unit 2 Technical Specifications for the Spring 2006 refueling outage (SL2-16). The report is to be submitted within one year of completing the refueling outage steam generator inservice inspection.

Please contact Ken Frehafer at (772) 467-7748 should you have any questions regarding this submittal.

Very truly yours, Gordon L. Johnit St. Lucie Plant GLJ/KWF Attachment

-ýOyý an FPL Group company

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 1 of 92 Attachment Steam Generator Tube Inservice Inspection Special Report

St. Lucie Unit 2 L-2007-076 Docket Ns. 50-389 Attachment Page 2 of 92 In accordance with Plant Technical Specification Section 4.4.5.5 (b), the attached information provides summarized results for the in-service examination of steam generator (SG) tubing.

1. In-service examination and plugging of the St. Lucie Unit 2 steam generators was completed between April 28, 2006 and May 14, 2006. The specific scope of examination for all techniques is provided below. This is also shown under "Total Tubes Inspected" on the attached "FORM NIS-BB OWNERS DATA REPORT FOR EDDY CURRENT EXAMINATION RESULTS".

Planned Examination Scope Bobbin coil examination:

100% full-length in rows 3 and higher. Row 1 & 2 examinations were limited to the hot leg and cold leg straight sections.

0 Screening of dings/dents < 5 volts in straight lengths (including horizontal runs).

+PointTM rotating probe examination:

100% of active hot leg tubes +3"/-13" as referenced from the top of tubesheet 0

All cold leg tubes in peripheral high flow regions for foreign object wear +3"/-2" as referenced from the top of tubesheet

  • Full depth tubesheet examination of all Hot & Cold Leg Tubes with No Tube Expansion 20% of row 1 & 2 U-bends All wear indications at the Hot Leg Diagonal Support Structures All wear indications at Horizontal Eggcrate Tube Supports 20% of wear indications at Vertical Supports in the U-bend region 0

All wear indications at the Cold Leg Diagonal Supports

  • Dings/Dents
  • All dings/dents between TSH +0.00" and 01H +1.00"
  • All dings/dents > 5.00 volts between 01H +1.00" and DHB -0.01"
  • All dings/dents in the H/L and C/L square bends for rows 19 - 140
  • All dings/dents > 5.00 volts in the horizontal runs of tubes in rows 19 - 140
  • All dings/dents in the U-Bend region for tubes in rows 1 - 18
  • All dings/dents measuring less than 5.0 volts at hot leg structures 20% of dings/dents > 5.00 volts in the cold leg straight sections Visual Examination 100% of all previously installed tube plugs were verified for location and condition.

Examination Scope Expansion

  • No expansions were required for the bobbin or rotating +PointTM probe examinations.
  • Installation of tube sleeves was not required for the SL2-16 inspection, and no tube sleeves are present in the steam generators for Cycle 16 operation. Therefore, no tube sleeves required inspection.

St. Lucie Unit 2 L-2007-076 Docket Ns. 50-389 Attachment Page 3 of 92

2. The location and percent of wall thickness penetration is summarized on the attached "FORM NIS-BB" under "Location of Indications". Three tubes (R43 L93, R48 L84, & R52 L84) in SG 2B were reported with hot leg and cold diagonal strap wear measuring > 40% by bobbin probe and were plugged. Only mechanical wear degradation was measured using qualified sizing techniques and left in service. A plug on detection approach was used for all other degradation mechanisms during this examination and therefore, no percent of wall thickness penetration is shown for other mechanisms in the attached indication listings.
3. One thousand and ninety (1090) tubes required plugging based on this examination. This includes 17 tubes in SG A and 4 tubes in SG B that were plugged preventively for wear indications ranging from 35 to 39% throughwall to provide additional margin for Cycle 16 operation. Two tubes were reported with single axial indications (SAI) at diagonal strap locations (RI L 109 @

DCT and R4 L30 @ DHB). Tube plugging is summarized in the upper section of the attached FORM NIS-BB. This section also identifies the number of tubes plugged preventatively (PTP) for other reasons such as 4 tubes in SG B to bound a foreign object that could not be removed and 1 tube for high extraneous noise levels.

4. Twelve hundred thirty (1230) mechanical wear indications (709 in SG A and 521 in SG B) ranged in depth from 1% to 34% TW and will remain in service for cycle 16 (Attachments 9 and 10 respectively).
5. The attached listings for SGs "A" & "B" are included as source documents for the preparation of "Form NIS-BB".

" SG "A" - Tubes with Bobbin Indications 35 - 100% TW and RPC repairable codes (Attachment 1 )

SG "A" - Tubes with Bobbin Indications 35 - 39% TW that were preventively plugged (Attachment 2)

SG "A" - Tubes with Bobbin Indications 20 - 34% TW (Attachment 3)

SG "A" - Tubes with Bobbin Indications 1 - 19% TW (Attachment 4)

SG "B" - Tubes with Bobbin Indications 35 - 100% TW and RPC repairable codes (Attachment 5)

SG "B" - Tubes with Bobbin Indications 35 - 39% TW that were preventively plugged (Attachment 6)

SG "B" - Tubes with Bobbin Indications 20 - 34% TW (Attachment 7)

SG "B" - Tubes with Bobbin Indications 1 - 19% TW (Attachment 8)

" SG "A" - Tubes with Bobbin Indications 1 - 34% TW Left in service (Attachment 9)

" SG "B" - Tubes with Bobbin Indications I - 34% TW Left in service (Attachment 10)

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 4 of 92 Plant:

St. Lucie Unit 2 Exam Dates:

April 28, 2006 to May 13, 2006 Tubes Total Tubes Total Tubes Tubes Plugged as Plugged Total Plugged Steam Total Tubes 20%-34%

>35% T.W. &

Preventive This Tubes in each Generator Inspected (4)

Axial Maintenance (PTP)

This SG Outage A

6942 240 463(1) 17(2) 463 1932 B

6702 137 622(1) 9(3) 627 2336 KLOCATION OF RINDICEATIONS L

(20%-~100% & AXIAL)

Partial U BENDS EGGCRATES Supports Top of Tube Sheet to Total Total Indications Steam DHB to 1 to 7 8 and 9

  1. 1 EGGCRATE Indications

>35% T.W. Circ.

Generator DCB 20%-34%

& Axial (4)(5)

(5)

H/L C/L H/L C/L H/L C/L A

19(6) 620 1

1 0

6 0

647(,)

306 3

4 8

2 0

0 32 11(7) 988 7

0 0

0 0

1006(7)

B 167 2

4 3

1 0

0 177 LOCATION OF INDICATIONS1Ž Total Total Indications EGGCRATES Partial Top of Tube Sheet to Indications 1%-34% Left in Steam Supports

  1. 1 EGGCRATE Generator U BENDS 1 to 7 8 and 9 1%-19%

Service for Cycle DHB to 5)16 DCB H/L C/L H/L C/L H/L C/L (5)

A 372 36 15 10 10 0

0 443 709 B

289 49 26 12 5

0 0

381 521

.Refer to the Remarks Section on the Following Page

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 5 of 92 Plant:

St. Lucie Unit 2 Exam Dates:

April 28, 2006 to May 13, 2006 Remarks:

(1)

No circumferential flaws were identified. This number also includes the PTP tubes with through wall depth (TWD) ranging between 35% and 39%.

(2)

Seventeen (17) tubes were preventively plugged (PTP) in SG A for through wall wear indications measuring from 35% to 39% to provide additional margin for Cycle 16 operation.

(3)

Four (4) tubes were preventively plugged (PTP) in SG B for through wall wear indications measuring from 35% to 39% to provide additional margin for Cycle 16 operation. Four (4) tubes were preventively plugged to bound a foreign object identified by FOSAR and confirmed by eddy current. No wear degradation was present in any of the tubes adjacent to the object. The part could not be removed and was dispositioned in Engineering Evaluation PSL-ENG-SEMS-98-101 Revision

5. One (1) tube was preventively plugged for inside diameter chatter (IDC) that could potentially mask a flaw.

(4)

Percent through-wall penetration is given only for mechanical wear indications at structures. Other degradation mechanisms are plugged on detection as depth sizing is not qualified for continued service.

(5)

Numbers are cumulative and include indications in tubes that are plugged for other reasons.

(6)

All indications in this category are wear related and range from 35% to 39% in depth.

(7)

Four (4) indications are wear related and range between 35% and 39% In depth, Four (4) indications are > 40% through-wall, and two (2) indications are axially orientated (SAI) crack indications located at Diagonal strap locations (R1 L109 @

DCT and R4 L30 @ DHB). R1 L109 also had SAI at eggcrate locations 07H and 07C.

(8)

Installation of tube sleeves was not required for the SL2-16 inspection, and no tube sleeves are present in the steam generators for Cycle 16 operation. Therefore, no tube sleeves required inspection.

Acronyms:

SAI-Single Axial Indication, SCI - Single Circumferential Indication, PTP - Preventative Tube Plug, TSH - Hot leg tubesheet Expansion, TSC - Cold leg Tubesheet expansion, VOL - Volumetric Indication, PLP - Possible Loose Part, TEH - Tube End Hot, TEC - Tube End Cold, DCT - Diagonal Cold Top, DHB - Diagonal Hot Bottom

St. Lucie Unit 2 Docket Ns. 50-3 89 L-2007-076 Attachment Page 6 of 92 Areva NP 6/7/2006 9:02 AM Component: S/G A Customer Name: St. Lucie Unit 2 Page 1 of 13 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS 1

165 0.24 2

158 0.48 3

15 0.27 0.19 3

25 0.20 0.22 3

29 0.16 3

31 0.15 3

155 0.16 4

40 0.29 4

148 0.36 5

149 0.15 6

6 0.33 6

108 0.26 7

3 0.33 0.23 7

133 0.16 8

42 0.14 8

126 0.22 8

162 0.15 9

13 0.14 9

25 0.26 0.17 9

107 0.12 9

121 0.18 10 116 0.14 10 120 0.17 0.14 0.39 0.15 10 128 0.26 11 17 0.10 11 21 0.22 11 29 0.26 11 131 0.17 12 12 0.14 0.21 0.26 0.19 0.24 0.31 0.36 12 14 0.13 12 18 0.20 0.24 0.18 0.17 12 32 0.30 12 40 0.32 12 60 0.30 12 126 0.22 12 150 0.23 DEG CHN IND %TW LOCATION EXT EXT CAL # LEG 95 P6 SAI 92 P6 SAI 87 P6 SAI 86 P6 SAI 64 P6 SAI 88 P6 MAI 96 P6 SAI 127 P6 SAI 69 P6 SAI 92 P6 SAI 93 P6 SAI 94 P6 SAI 46 P6 SAI 97 P6 SAI 86 P6 SAI 82 P6 SAI 117 P6 SAI 43 P6 SAI 72 P6 SAI 89 P6 SAI 93 P6 SAI 81 P6 SAI 78 P6 SAI 52 P6 SAI 80 P6 SAI 74 P6 SAI 81 P6 SAI 85 P6 SAI 108 P6 SAI 76 P6 SAI 91 P6 SAI 98 P6 SAI 101 P6 SAI 58 P6 MAI 63 P6 SAI 33 P6 SAI 88 P6 SAI 105 P6 SAI 92 P6 SAI 91 P6 SAI 103 P6 SAI 84 P6 SAI 77 P6 SAT 92 P6 SAI 102 P6 MAI 79 P6 MAI 105 P6 SAI 92 P6 SAI 119 P6 SAI 103 P6 MAI 129 P6 SAI 84 P6 SAI 02H 03H 03H 03H 01H 03H 03H 01H 03H 07H 03H 02H 03H 07C 03H 03H 02H 03H 03H 04H 01H 03H 03H 03H 05H 05H 01H 01H 02H 02H 03H 02H 05H 01H 01H 03H 03H 02H 02H 04H 05H 05H 01H 05H 05H 07H 07H 03H 03H 01H 02H 03H

+0.92

+0.66

-0.66

+0.42

+0.01

+0.86

+0.83

+0.16

+0.43

+0.51

+0.56

-0.42

+0.44

+0.77

+0.04

-0.28

+0.18

+0.76

-0.23

+0.60

-0.27

+0.10

+0.45

-0.22

+0.55

+0.34

-0.15

-0.91

+0.52

-0.82

+0.64

-0.49

+0.83

-0.51

+0.97

-0.50

+0.69

-0.82

+0.55

-0.74

-0.28

+0.69

+0.89

-0.50

+0.80

-0.51

+0.67

+0.68

-0.42

+0.15

-0.51

+0.00 02H 02H 88 03H 03H 88 03H 0311 92 03H 03H 92 01H 01H 108 03H 03H 92 03H 03H 92 01H 01H 92 03H 03H 88 07H 07H 92 03H 03H 88 02H 02H 88 03H 03H 110 07C 07C 83 03H 03H 110 03H 03H 110 02H 02H 88 03H 03H 125 03H 03H 88 04H 04H 88 01H 01H 110 03H 03H 108 03H 03H 108 03H 03H 88 05H 05H 88 05H 05H 88 01H 01H 111 01H 01H 111 02H 02H 88 02H 02H 88 03H 03H 88 02H 02H 108 05H 05H 108 01H 01H 92 01H 01H 88 03H 03H 125 03H 03H 125 02H 02H 110 02H 02H 110 04H 04H 110 05H 05H 110 05H 05H 110 01H 01H 110 05H 05H 108 05H 05H 108 07H 071H 108 07H 0711 108 03H 03H 108 03H 03H 53 01H 01H 58 02H 02H 68 03H 03H 88 HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 7 of 92 Areva NP 6/7/2006 9:02 AM Component: S/G A Customer Name: St. Lucie Unit 2 Paqe 2 of 13 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS DEG CHN IND %TW LOCATION 0.14 13 21 0.18 0.52 13 39 0.16 13 49 0.36 13 59 0.27 13 113 0.29 14 4

0.16 14 18 0.28 14 140 0.34 0.13 14 142 0.25 0.27 14 146 0.20 15 7

0.31 15 9

0.36 15 21 0.20 0.24 15 23 0.13 0.18 0.27 15 61 0.33 0.28 15 117 0.17 15 129 0.17 16 8

0.33 0.22 16 50 0.21 0.16 16 110 0.44 16 124 0.26 16 144 0.20 16 146 0.23 16 150 0.33 17 31 0.15 17 39 0.37 17 133 0.22 17 137 0.14 17 141 0.19 18 6

0.22 18 142 0.20 18 150 0.22 19 21 0.25 19 27 0.28 19 49 0.44 19 59 0.19 19 151 0.15 0.32 20 10 0.17 20 18 0.12 0.33 0.09 124 P6 88 P6 98 P6 92 P6 106 P6 74 P6 93 P6 97 P6 91 P6 121 P6 83 P6 93 P6 97 P6 64 P6 127 P6 106 P6 103 P6 104 P6 111 P6 31 P6 94 P6 91 P6 90 P6 73 P6 119 P6 133 P6 93 P6 103 P6 92 P6 107 P6 91 P6 74 P6 84 P6 104 P6 50 P6 109 P6 79 P6 31 P6 95 P6 115 P6 81 P6 109 P6 104 P6 134 P6 95 P6 48 P6 73 P6 112 P6 92 P6 58 P6 97 P6 56 P6 SAT SAT SAT SAT SAI SAI SAT MAI SAT SAT SAT SAT SAT SAI SAI SAI SAT SAI SAT SAT SAT SAT SAT SAT SAT SAT SAT SAT SAT SAT SAT SAT SAT SAT MAI SAT SAT SAT SAT SAT SAT SAT SAI SAI SAT SAT SAT SAT SAT SAI SAT SAI 03H

-0.80 03H

-0.26 03H

+0.23 03H

+0.84 07H

+0.85 01H

-0.67 06H

-0.39 03H

+0.91 02H

-0.30 03H

-0.26 03H

+0.96 03H

+0.83 04H

+0.84 02H

-0.32 03H

-0.40 03H

+0.79 03H

+0.70 03H

+0.93 03H

-0.66 03H

-0.36 03H

+0.93 06H

-0.19 01H

-0.75 03H

-0.16 02H

+0.43 03H

-0.07 03H

+1.00 07H

+0.78 07H

-0.51 06H

-0.63 04H

+0.73 01H

+0.44 01H

-0.70 04H

+0.21 01H

-0.80 03H

+0.74 01H

+0.80 02H

-0.14 05H

+0.90 03H

+0.76 01H

+0.76 01H

-0.67 01H

-0.84 03H

-0.63 01H

-0.29 02H

-0.26 01H

-0.60 03H

+0.28 03H

+0.98 02H

+0.72 03H

+0.80 02H

-0.86 EXT EXT CAL # LEG 03H 03H 88 HOT 03H 03H 108 HOT 03H 03H 108 HOT 03H 03H 53 HOT 07H 07H 53 HOT 01H 01H 58 HOT 06H 06H 68 HOT 03H 03H 110 HOT 02H 02H 108 HOT 03H 03H 88 HOT 03H 03H 88 HOT 03H 03H 88 HOT 04H 04H 88 HOT 02H 02H 88 HOT 03H 03H 110 HOT 03H 03H 110 HOT 03H 03H 108 HOT 03H 03H 108 HOT 03H 03H 92 HOT 03H 03H 92 HOT 03H 03H 92 HOT 06H 06H 94 HOT 01H 01H 110 HOT 03H 03H 68 HOT 02H 02H 68 HOT 03H 03H 110 HOT 03H 03H 110 HOT 07H 07H 53 HOT 07H 07H 53 HOT 06H 06H 68 HOT 04H 04H 68 HOT 01H 01H 88 HOT 01H 01H 88 HOT 04H 04H 88 HOT 01H 01H 92 HOT 03H 03H 53 HOT 01H 01H 88 HOT 02H 02H 88 HOT 05H 05H 88 HOT 03H 03H 110 HOT 01H 01H 88 HOT 01H 01H 88 HOT 01H 01H 108 HOT 03H 03H 108 HOT 01R 01H 53 HOT 02H 02H 58 HOT 01H 01H 88 HOT 03H 03H 88 HOT 03H 03H 110 HOT 02H 02H 108 HOT 03H 03H 108 HOT 02H 02H 108 HOT PROBE 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803p 5803p 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 8 of 92 Areva NP 6/7/2006 9:02 AM Component: S/G A Attachment I

Customer Name: St. Lucie Unit 2 Page 3 of 13 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS 20 154 0.24 21 17 0.40 21 25 0.18 0.20 21 47 0.26 22 112 0.16 22 146 0.22 23 45 0.41 0.19 0.30 23 49 0.43 23 117 0.25 23 125 0.31 0.16 23 135 0.25 23 149 0.14...

24 14 0.11 0.17 24 120 0.32 24 130 0.22 24 132 0.30 24 148 0.21 25 47 0.24 27 21 0.22 27 45 0.23 27 55 0.34 27 105 0.28 27 131 0.15 27 139 0.19 0.32 27 141 0.27 0.17 0.14 28 34 0.16 0.22 0.26 28 130 0.16 0.20 28 134 0.20 28 140 0.21 29 19 0.12 29 31 0.17 0.18 29 107 0.53 29 117 0.31 29 145 0.25 30 10 0.16 30 30 0.16 0.10 30 34 0.27 30 38 0.34 30 42 0.28 DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 138 P6 SAI 102 P6 SAI 84 P6 SAI 75 P6 SAI 107 P6 SAI 76 P6 SAI 90 P6 SAI III P6 SAI 78 P6 SAI 76 P6 SAI 94 P6 SAI 75 P6 SAI 87 P6 SAI 116 P6 SAI 67 P6 MAI 75 P6 SAT 80 P6 SAI 106 P6 SAI 89 P6 SAI 77 P6 SAI 99 P6 SAI 107 P6 SAI 57 P6 SAI 124 P6 SAI 75 P6 SAI 88 P6 SAI 84 P6 SAI 56 P6 MAI 73 P6 SAI 78 P6 SAI 98 P6 SAI 74 P6 SAI 93 P6 SAI 79 P6 SAI 83 P6 MAI 98 P6 SAI 65 P6 SAI 166 P6 SAI 68 P6 SAI 58 P6 SAI 56 P6 SAI 63 P6 SAI 94 P6 SAI 19 2

SAI 84 P6 SAI 68 P6 SAI 103 P6 SAI 175 P6 SAI 31 P6 SAI 92 P6 SAI 103 P6 SAI 107 P6 SAI 03H 03H 01H 01H 05H 05H 01H 05H 01H 03H 01H 04H 04H 01H 01H 01H 01H 03H 05H 02H 01H 01H 01H 03H 01H 02H 01H 04H 01H 03H 01H 01H 01H 02H 03H 05H 02H 02H 01H 03H 02H 01H 03H TSH 01H 03H 01H 03H 03H 01H 04H 01H

-0.38

+0.55

-0.32

+0.14

+0.85

-0.47

-0.86

+0.77

-0.40

+0.85

-0.49

+0.83

+0.60

-0.75

+0.51

-0.9.0

+0.86

+0.94

+0.46

+0.98

+0.63

-0.61

-0.34

+0.92

-0.38

+0.42

-0.48

+0.72

+0.56

+0.96

-0.17

+0.24

+0.56

-0.61

+0.42

+0.66

+1.01

+0.40

-0.21

+0.95

+0.94

-0.18

+0.90

-0.69

+0.83

+0.90

+0.87

-0.31

+0.83

+0.67

+0.97

-0.27 03H 03H 03H 03H 01H 01H 01H 01H

.05H 05H 05H 05H 01H 01H 05H 05H 01H 01H 03H 03H 01H 01H 04H 04H 04H 04H 01H 01H 01H 01H 01H 01H 01H 01H 03H 03H 05H 05H 02H 02H 01H 01H 01H 01H 01H 01H 03H 03H 01H 01H 02H 02H 01H 01H 04H 04H 01H 01H 03H 03H 01H 01H 01H 01H 01H 01H 02H 02H 03H 03H 05H 05H 02H 02H 02H 02H 01H 01H 03H 03H 02H 02H 01H 01H 03H 03H TSH TSH 01H 01H 03H 03H 01H 01H 03H 03H 03H 03H 01H 01H 04H 04H 01H 01H 88 HOT 5803P 108 HOT 5803P 92 HOT 5803P 92 HOT 5803P 53 HOT 5803?

68 HOT 5803P 88 HOT 5803P 53 HOT 5803P 92 HOT 5803P 92 HOT 5803P 53 HOT 5803P 68 HOT 5803P 68 HOT 5803P 68 HOT 5803P 88 HOT 5803P 88 HOT 5803?

110 HOT 5803P 110 HOT 5803P 68 HOT 5803P 88 HOT 5803P 88 HOT 5803P 88 HOT 5803P 92 HOT 5803P 108 HOT 5803P 53 HOT 5803P 53 HOT 5803P 68 HOT 5803P 88 HOT 5803P 88 HOT 5803P 88 HOT 5803P 88 HOT 5803P 88 HOT 5803P 88 HOT 5803P 108 HOT 5803P 108 HOT 5803P 108 HOT 5803P 88 HOT 5803P 88 HOT 5803P 88 HOT 5803P 88 HOT 5803P 110 HOT 5803P 108 HOT 5803P 92 HOT 5803P 7

HOT 5803P 68 HOT 5803P 88 HOT 5803P 110 HOT 5803P 108 HOT 5803P 108 HOT 5803P 92 HOT 5803P 53 HOT 5803P 53 HOT 5803P

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 9 of 92 Areva NP 6/7/2006 9:02 AM Component: S/G A Customer Name: St.

Lucie Unit 2 Page 4 of 13 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS 30 130 0.34 30 138 0.24 0.23 31 21 0.44 31 57 0.33 31 63 0.21 31 117 0.15 31 125 0.27 32 18 0.15 0.44 32 22 0.28 32 46 0.21 32 50 0.36 32 132 0.17 32 134 0.17 33 15 0..13.,

33 55 0.27 34 12 0.38 34 20 0.34 34 40 0.11 0.25 34 58 0.38 34 106 0.31 34 150 0.23 35 13 0.21 35 37 0.23 35 69 0.88 36 44 0.26 0.28 36 52 0.14 36 100 0.19 36 122 0.30 37 11 0.14 0.26 37 23 0.16 0.48 0.21 0.36 37 69 0.91 37 103 0.30 37 105 0.20 37 109 0.72 37 125 0.23 37 133 0.75 37 139 0.58 38 96 1.08 38 116 0.26 39 21 0.51 0.13 39 47 0.25 39 67 0.22 39 135 0.27 DEG CHN IND %TW LOCATION EXT EXT CAL # LEG 98 P6 SAI 102 P6 SAI 104 P6 SAI 89 P6 SAI 77 P6 SAI 62 P6 SAI 40 P6 SAI 60 P6 SAI 136 P6 SAI 105 P6 SAI 102 P6 SAI 60 P6 SAI 58 P6 MAI 105 P6 SAI 61 P6 SAI 50 P6 SAI.

71 P6 SAI 106 P6 SAI 98 P6 SAI 61 P6 SAI 99 P6-SAI 107 P6 SAI 97 P6 SAI 75 P6 SAI 104 P6 SAI 60 P6 MAI 80 P2 TWD 35 100 P6 MAI 80 P6 SAI 91 P6 SAI 81 P6 SAI 119 P6 SAI 178 P6 SAI 90 P6 SAI 80 P6 SAI 94 P6 SAI 83 P6 SAI 96 P6 SAI 94 P2 TWD 35 70 P6 SAI 82 P6 SAI 89 P6 SAI 110 P6 SAI 96 P6 SAI 101 P6 SAI 97 P2 TWD 35 84 P6 SAI 95 P6 SAI 92 P6 SAI 87 P6 SAI 105 P6 SAI 75 P6 SAI 02H 03H 05H 02H 01H 03H 04H 01H 03H 03H 03H 01H 01H 01H 02H 01H..

01H 02H 03H 03H 03H 02H 03H 03H 02H 03H DCB 04H 04H 03H 03H 02H 02H 02H 01H 01H 02H 03H DCB 01H 01H 02H 04H 01H 02H DCB 04H 03H 03H 02H 01H 01H

+0.13

+0.91

-0.21

-0.18

-0.65

+0.75

+0.85

-0.22

-0.48

+0.77

+0.67

-0.33

-0.77

+0.16

+0.88

+0..64.

+0.91

+0.88

+0.88

-0.88

+0.91

+0.47

+0.51

+0.42

+0.89

+0.98

+0.67

-0.75

+0.62

+0.94

+0.56

+0.70

-0.83

+0.71

-0.85

+0.68

+0.81

+0.55

+0.47

+0.49

+0.78

-0.57

-0.28

-0.01

+0.47

+0.00

+0.76

-0.04

+0.91

+0.53

+0.43

+0.29 02H 02H 88 03H 03H 88 05H 05H 88 02H 02H 108 01H 011H 58 03H 03H 58 04H 04H 68 01H 01H 68 03H 03H 110 03H 03H 110 03H 03H 108 01H 01H 53 01H 01H 53 01H 01H 88 02H 02H 71 01 1H_.110.

01H 01H 92 02H 02H 110 03H 03H 108 03H 03H 53 03H 03H 53 02H 02H 58 03H 03H 68 03H 03H 88 02H 02H 110 03H 03H 92 TEH TEC 43 04H 04H 53 04H 04H 53 03H 03H 53 03H 03H 68 02H 02H 68 02H 02H 110 02H 02H 110 01H 01H 108 01H 01H 108 02H 02H 108 03H 03H 108 TEH TEC 43 01H 01H 68 01H 01H 68 02H 02H 68 04H 04H 68 01H 01H 88 02H 02H 88 TEH TEC 3

04H 04H 68 03H 03H 108 03H 03H 108 02H 02H 53 01H 01H 94 01H 01H 88 HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD HOT HOT HOT HOT HOT HOT COLD HOT HOT HOT HOT HOT HOT PROBE 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P-5803RP 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 600IUL 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 60OU~L 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P

St. Lucie Unit 2 L-2007-076 Docket Ns. 50-389 Attachment Page 10 of 92 Areva NP 6/7/2006 9:02 AM Attachment 1

Customer Name: St.

Lucie Unit 2 Component: S/G A Page 5 of 13 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 40 10 0.26 111 P6 SAI 03H

-0.81 03H 03H 110 HOT 5803P 40 12 0.20 71 P6 SAI 02H

-0.95 02H 02H 110 HOT 5803P 0.14 64 P6 SAI 02H

-0.77 02H 02H 110 HOT 5803P 40 18 0.36 111 P6 SAI 03H

-0.20 03H 03H 110 HOT 5803P 0.27 113 P6 SAI 03H

+0.96 03H 03H 110 HOT 5803P 40 28 0.31 82 P6 SAI 01H

-0.22 01H 01H 92 HOT 5803P 0.22 117 P6 SAI 01H

-0.73 01H 01H 92 HOT 5803P 40 34 0.58 95 P6 SAI 01H

+0.28 01H 01H 92 HOT 5803P 40 48 0.27 90 P6 SAI 04H

+0.69 04H 04H 53 HOT 5803P 0.25 79 P6 MAI 02H

-0.27 02H 02H 92 HOT 5803P 0.32 95 P6 MAI 02H

+0.58 02H 02H 92 HOT 5803P 40 52 0.58 98 P6 MAI 04H

+0.86 04H 04H 53 HOT 5803P 40 54 0.38 97 P6 SAI 02H

-0.24 02H 02H 53 HOT 5803P 0.18 104 P6 SAI 02H

+0.65 02H 02H 53 HOT 5803P 40 118 0.18 53 P6 SAI 01H

-0.36 01H 01H 68 HOT 5803P 0.19 61 P6 SAI_-

01H-...

+0.56-01HW 01H_ 68 HOT 5803P.

41 27 0.33 88 P6 MAI 03H

+0.46 03H 03H 92 HOT 5803P 41 39 0.16 119 P6 SAI 02H

+0.86 02H 02H 53 HOT 5803P 41 47 0.22 94 P6 SAI 05H

+0.88 05H 05H 53 HOT 5803P 41 99 0.50 103 P6 SAI 02H

+0.76 02H 02H 61 HOT 5803?

41 113 0.15 102 P6 SAI TSH

+0.20 TSH TSH 7

HOT 5803P 42 36 0.19 78 P6 MAI 01H

+0.76 01H 01H 108 HOT 5803P 42 40 0.48 92 P6 SAI 01H

-0.68 01H 01H 53 HOT 5803P 42 70 0.90 98 P2 TWD 35 DCB

+0.34 TEH TEC 43 COLD 600UL 42 72 0.82 90 P2 TWD 36 DHB

+0.00 TEH TEC 6

COLD 600UL 43 9

0.28 90 P6 SAI 02H

-0.89 02H 02H 110 HOT 5803?

0.42 98 P6 SAI 02H

+0.83 02H 02H 110 HOT 5803P 43 45 0.30 73 P6 SAI 01H

-0.31 01H 01H 53 HOT 5803P 0.20 83 P6 SAI 01H

+0.87 01H 01H 53 HOT 5803P 43 73 0.23 83 P6 SAI 01H

-0.11 01H 01H 58 HOT 5803P 43 95 0.41 73 P6 SAI 02H

+0.72 02H 02H 61 HOT 5803P 44 6

0.16 100 P6 SAI 01H

+0.87 01H 01H 110 HOT 5803P 44 18 0.18 116 P6 SAI 01H

+0.96 01H 01H 110 HOT 5803P 0.19 55 P6 SAI 03H

-0.57 03H 03H 110 HOT 5803P 0.15 79 P6 MAI 03H

+0.68 03H 03H 110 HOT 5803P 44 48 0.29 89 P6 SAI 01H

+0.79 01H 01H 53 HOT 5803P 0.23 83 P6 SAI 04H

+0.88 04H 04H 53 HOT 5803P 0.39 85 P6 SAI 02H

+0.44 02H 02H 92 HOT 5803P 44 52 0.24 96 P6 SAI 03H

+0.89 03H 03H 53 HOT 5803P 44 64 0.18 88 P6 SAI 01H

+0.78 01H 01H 58 HOT 5803P 0.19 98 P6 SAI 02H

+0.95 02H 02H 58 HOT 5803P 44 96 0.21 66 P6 SAI 02H

-0.33 02H 02H 61 HOT 5803P 44 98 0.36 111 P6 SAI 02H

+0.21 02H 02H 61 HOT 5803P 0.26 80 P6 SAI 02H

+0.57 02H 02H 61 HOT 5803P 44 132 0.33 89 P6 SAI 01H

+0.89 01H 01H 88 HOT 5803P 45 13 0.18 93 P6 SAI 02H

+0.73 02H 02H 110 HOT 5803P 45 45 0.56 105 P6 SAI 01H

+0.10 01H 01H 53 HOT 5803P 0.15 73 P6 SAI 01H

+0.72 01H 01H 53 HOT 5803P 0.27 85 P6 SAI 01H

+0.92 01H 01H 53 HOT 5803P 45 121 0.13 79 P6 SAI 03H

+0.87 03H 03H 68 HOT 5803?

46 18 0.20 82 P6 SAI 03H

-0.36 03H 03H 110 HOT 5803P 0.15 27 P6 SAI 03H

-0.62 03H 03H 110 HOT 5803P

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 11 of 92 Areva NP 6/7/2006 9:02 AM Component: S/G A Attachment 1

Customer Name: St. Lucie Unit 2 Page 6 of 13 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 46 20 0.17 0.13 47 33 0.12 0.17 0.52 47 37 0.26 47 157 0.26 48 18 0.13 48 32 0.23 48 48 0.27 48 56 0.22 48 122 0.72 49 15 0.23 49 43 0.20 0.21 49 53 0.26 49 65 0.61 49 79 0.93 49 87 0.99 49 95 0.47 49 131 0.28 0.17 50 110 0.11 50 136 0.24 51 77 0.97 51 79 1.45 51 83 0.19 51 99 0.32 51 131 0.16 51 139 0.24 52 42 0.28 52 88 0.42 52 94 0.29 53 39 0.20 0.33 53 57 0.18 0.11 0.28 0.28 53 77 1.12 53 89 0.26 0.29 53 91 0.46 53 93 0.44 0.79 53 95 0.40 0.55 54 16 0.22 0.19 54 20 0.13 54 22 0.21 54 40 0.22 95 P6 71 P6 87 P6 77 P6 88 P6 82 P6 96 P6 88 P6 70 P6 100 P6 72 P6 94 P6 76 P6 108 P6 100 P6 93 P6 102 P6 86 P2 102 P2 98 P6 87 P6 61 P6 92 P6 59 P6 99 P2 90 P2 58 P6 94 P6 55 P6 79 P6 88 P6 97 P6 101 P6 83 P6 93 P6 84 P6 113 P6 99 P6 88 P6 117 P2 100 P6 98 P6 95 P6 95 P6 96 P6 90 P6 93 P6 117 P6 90 P6 86 P6 65 P6 57 P6 SAI MAI SAI SAI SAI SAT SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI TWD 38 TWD 37 SAI SAI SAI SAI MAI TWD 38 TWD 37 SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI TWD 35 SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI 03H 03H 03H 04H 05H 01H 02H 01H 01H 01H 03H 02H 03H 03H 02H 04H 01H VS3 DCT 02H 01H 01H TSH 01H DCT DCT 01H 03H 01H 01H 01H 01H 02H 03H 01H 01H 02H 02H 04H DHB 06H 06H 02H 02H 04H 01H 02H 04H 03H 03H 04H 02H

+0.46

+0.78

+0.16

+0.51

+0.79

-0.49

-0.53

-0.71

-0.74

+0.72

+0.84

-0.49

+0.68

+0.89

+0.80

-0.64

-0.41

+0.94

+0.00

+0.82

-0.82

+0.20

+0.15

-0.80

+0.00

+0.00

+0.27

+0.89

-0.92

-0.64

-0.59

-0.72

+0.77

+0.96

-0.62

-0.34

-0.52

+0.03

+0.16

+2.00

-0.53

+0.80

+0.35

+0.79

+0.73

-0.16

+0.75

+0.84

-0.30

+0.94

+0. 90

+0.83 03H 03H 03H 03H 03H 03H 04H 04H 05H 05H 01H 01H 02H 02H 01H 01H 01H 01H 01H 01H 03H 03H 02H 02H 03H 03H 03H 03H 02H 02H 04H 041H 01H 01H TEH TEC TEH TEC 02H 02H 01H 011i 01H 01H TSH TSH 01H 01H TEH TEC TEH TEC 01H 01H 03H 03H 01H 01H 01H 01H 01H 01H 01H 01H 02H 02H 03H 03H 01H 01H 01H 01H 02H 02H 02H 0211 04H 04H TEH TEC 06H 06H 06H 06H 02H 02H 02H 02H 04H 04H 01H 01H 02H 02H 04H 04H 03H 03H 03H 03H 04H 04H 02H 02H 110 110 125 125 108 108 88 110 108 53 53 68 110 53 92 53 58 6

4 61 88 88 7

88 6

5 74 61 88 88 53 61 61 53 92 110 92 92 92 5

61 61 61 61 61 61 61 110 125 110 110 53 HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD HOT HOT HOT HOT HOT COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 600UL 600UL 5803P 5803P 5803P 5803P 5803P 600UL 600UL 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 600UL 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 12 of 92 Areva NP 6/7/2006 9:02 AM Component: S/G A Customer Name: St. Lucie Unit 2 Page 7 of 13 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS 0.27 0.27 54 42 0.44 0.17 54 136 0.43 55 19 0.30 55 25 0.34 0.17 55 55 0.25 56 50 0.16 56 68 0.13 0.15 56 86 1.14 56 98 0.15 0.30 0.24 56 110 0.32 58 20 0.34 58 24 0.61 0.77 58 60 0.27 58 78 0.33 58 92 0.17 0.28 58 134 0.22 60 104 0.17 61 17 0.13 0.17 61 79 0.79 61 91 0.60 0.25 0.27 61 97 0.58 0.22 62 38 0.15 62 80 0.81 62 92 0.22 63 17 0.15 63 51 0.22 0.19 63 77 0.37 0.22 63 81 0.22 63 93 0.32 0.38 0.15 0.13 0.21 0.20 63 97 0.33 0.20 64 14 0.12 DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 78 P6 73 P6 87 P6 51 P6 96 P6 119 P6 88 P6 79 P6 105 P6 70 P6 61 P6 64 P6 110 P2 76 P6 85 P6

71.

P6 106 P6 265 P6 96 P6 98 P6 77 P6 90 P6 79 P6 90 P6 94 P6 78 P6 93 P6 50 P6 112 P2 91 P6 97 P6 84 P6 97 P6 79 P6 84 P6 73 P2 87 P6 80 P6 79 P6 79 P6 103 P6 67 P6 87 P6 94 P6 84 P6 58 P6 74 P6 83 P6 98 P6 88 P6 77 P6 84 P6 SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI MAI TWD 36 SAI SAI SAL SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI TWD 36 SAI SAI SAI SAI SAI SAI TWD 36 SAI SAI SAI SAI MAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI 01H 01H 01H 01H 01H 03H 02H 02H 02H 01H 01H 01H DCB 02H 03H 03H 02H 03H 01H 02H 05H 01H 01H 01H 01H 02H 02H 02H DCB 01H 01H 01H 03H 03H 06H DCB 04H 02H 01H 01H 03H 04H 01H 01H 01H 01H 03H 05H 02H 01H 01H 02H

-0.38

+0.82

-0.26

+0.87

-0.60

+0.94

-0.72

+0.02

-0.50

-0.20

-0.61

+0.44

+0.00

+0.86

-0.17

+0.73

+0.60

+0.88

+0.02

+0.69

+0.57

+0.78

-0.22

+0.26

+0.85

+0.49

-0.63

+0.77

+0.00

-0.72

-0.06

+0.85

-0.33

+0.86

+0.78

+0.00

+0.80

+0.95

-0.10

+0.76

+0.80

+0.88

+0.77

-0.69

+0.28

+0.93

+0.87

-0.24

+0.77

+0.35

-0.23

-0.79 01H 01H 01H 01H 01H 01H 01H 01H 01H 01H 03H 03H 02H 02H 02H 02H 02H 02H 01H 01H 01H 01H 01H 01H TEH TEC 02H 02H 03H 03H 03H 03H 02H 02H 03H 03H 01H 01H 02H 02H 05H 05H 01H 01H 01H 01H 01H 01H 01H 01H 02H 02H 02H 02H 02H 02H TEH TEC 01H 01H 01H 01H 01H 01H 03H 03H 03H 03H 06H 06H TEH TEC 04H 04H 02H 02H 01H 01H 01H 01H 03H 03H 04H 04H 01H 01H 01H 01H 01H 01H 01H 01H 03H 03H 05H 05H 02H 02H 01H 01H 01H 01H 02H 02H 92 92 53 53 88 110 108 108 53 53 61 61 3

90 61 61 68 107 107 107 58 61 61 61 88 68 107 107 6

61 61 61 61 61 53 6

61 107 53 53 61 61 61 61 61 61 61 61 61 61 61 107 HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD HOT HOT HOT-HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD HOT HOT HOT HOT HOT HOT COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 600UL 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 600UL 5803P 5803P 5803P 5803P 5803P 5803P 600UL 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P

St. Lucie Unit 2 Docket Ns. 50-389 Areva NP L-2007-076 Attachment Page 13 of 92 6/7/2006 9:02 AM Component: S/G A Customer Name: St. Lucie Unit 2 Page 8 of 13 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG 64 32 0.41 64 36 0.16 0.19 64 54 0.43 0.28 64 60 0.49 0.14 0.21 64 74 0.41 0.27 64 80 0.26 64 88 0.22 0.13 0.13 0.12 64 96 0.2.9 0.35 64 152 0.10 65 15 0.24 65 31 0.28 65 41 0.28 0.27 0.53 65 43 0.32 65 47 0.18 65 85 0.42 65 87 0.36 0.23 65 91 0.19 0.18 66 14 0.09 66 20 0.31 0.29 66 38 0.30 66 46 0.15 66 48 0.43 66 58 0.37 66 64 0.25 66 76 0.40 0.53 0.23 67 13 0.10 67 25 0.16 67 53 0.25 0.30 67 57 0.43 0.17 67 97 0.31 67 131 0.24 68 44 0.41 0.38 68 80 0.19 277 P6 272 P6 66 P6 96 P6 95 P6 107 P6 60 P6 78 P6 95 P6 95 P6 96 P6 98 P6 66 P6 83 P6 86 P6 107 P6 100 P6 87 P6 102 P6 78 P6 90 P6 92 P6 94 P6 82 P6 92 P6 90 P6 96 P6 78 P6 90 P6 92 P6 71 P6 278 P6 106 P6 88 P6 75 P6 102 P6 110 P6 108 P6 89 P6 101 P6 86 P6 73 P6 281 P6 89 P6 89 P6 92 P6 61 P6 77 P6 83 P6 91 P6 79 P6 85 P6 SAI SAI SAI SAI SAI SAI SAI MAI SAI SAI SAI SAI SAI SAI SAI MAI SAI SAI SAI SAI SAI SAI SAI SAI MAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI 06H

-0.05 06H 06H 107 01H

-0.36 01H 01H 107 04H

+0.89 04H 04H 92 01H

-0.87 01H 01H 53 01H

+0.64 01H 01H 53 01H

-0.30 01H 01H 61 01H

+0.42 01H 01H 61 01H

+0.87 01H 01H 61 02H

-0.31 02H 02H 61 02H

+0.81 02H 02H 61 04H

+0.81 04H 04H 61 03H

-0.12 03H 03H 61 03H

+0.28 03H 03H 61 03H

+0.92 03H 03H 61 06H

+0.98 06H 06H 61 01H-73 01H 01H-61-01H

+0.75 01H 01H 61 04H

-0.53 04H 04H 88 02H

+0.78 02H 02H 107 01H

+0.68 01H 01H 92 01H

-0.53 01H 01H 53 03H

+0.77 03H 03H 53 02H

+0.06 02H 02H 92 01H

-0.61 01H 01H 53 01H

-0.19 01H 01H 53 01H

-0.41 01H 01H 61 01H

-0.52 01H 01H 61 01H

+0.63 01H 01H 61 02H

+0.93 02H 02H 61 03H

-0.50 03H 03H 61 03H

-0.25 03H 03H 107 02H

+0.73 02H 02H 107 03H

+0.88 03H 03H 107 01H

-0.52 01H 01H 53 01H

-0.68 01H 01H 107 01H

-0.32 01H 01H 53 02H

+0.52 02H 02H 61 01H

-0.39 01H 01H 94 03H

-0.26 03H 03H 90 03H

+0.19 03H 03H 90 04H

-0.67 04H 04H 90 04H

+0.84 04H 04H 107 04H

+0.88 04H 04H 107 01H

-0.75 01H 01H 53 01H

-0.37 01H 01H 53 01H

-0.68 01H 01H 61 01H

+0.87 01H 01H 61 02H

+0.93 02H 02H 61 02H

-0.45 02H 02H 88 01H

-0.10 01H 01H 53 02H

+0.29 02H 02H 53 05H

+0.94 05H 05H 61 HOT HOT HOT HOT HOT HOT HOT NOT NOT HOT HOT HOT HOT HOT HOT HOT-HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT NOT HOT NOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 5 803 P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P

St. Lucie Unit 2 Docket Ns. 50-3 89 L-2007-076 Attachment Page 14 of 92 Areva NP 6/7/2006 9:02 AM Component:

S/G A Attachment I Customer Name: St. Lucie Unit 2 Page 9 of 13 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG 68 88 0.25 0.22 68 92 0.23 0.19 0.24 0.22 68 112 0.44 69 45 0.31 69 59 0.38 69 99 0.21 70 28 0.21 70 30 0.20 70 46 0.16 0.19 0.14 0.37 70 66 0.17 0.55 70 68 0.18 0.18 0.18 70 104 0.14 70 132 0.31 70 136 0.19 71 29 0.17 0.36 71 37 0.21 71 41 0.15 71 89 0.28 71 131 0.30 73 21 0.32 73 71 0.17 73 83 0.18 74 62 0.12 74 136 0.25 0.21 75 45 0.40 75 79 0.19 75 93 0.42 75 95 0.57 0.46 76 26 0.17 0.16 0.39 76 40 0.16 0.22 76 46 0.56 0.26 0.37 76 96 0.21 0.15 77 81 0.35 122 P6 SAI 02H

+0.93 74 P6 SAI 05H

+0.94 103 P6 SAI 01H

-0.46 48 P6 SAI 01H

-0.15 94 P6 SAI 01H

+0.35 60 P6 SAI 01H

+0.93 101 P6 SAI 01H

-0.14 76 P6 SAI 02H

+0.42 81 P6 SAI 02H

+0.91 157 P6 SAI 03H

-0.13 102 P6 SAI 02H

+0.90 88 P6 SAI 02H

+0.85 93 P6 SAI 01H

-0.69 93 P6 SAI 01H

-0.38 117 P6 SAI 01H

+0.85 107 P6 SAI 02H

+0.51 78 P6 SAI 02H

-0.27 94 P6 SAI 02H

+0.69 87 P6 SAI 03H

-0.71 67 P6 SAI 03H

+0.09 68 P6 SAI 03H

+0.72 84 P6 SAI 01H

+0.27 79 P6 SAI 01H

-0.63 73 P6 SAI 01H

-0.47 61 P6 SAI 02H

-0.84 92 P6 SAI 02H

+0.86 261 P6 SAI 03H

+0.72 87 P6 SAI 02H

+0.89 88 P6 SAI 07H

+0.41 99 P6 SAI 01H

+0.59 83 P6 SAI 02H

+0.16 105 P6 SAI TSH

+0.15 126 P6 SAI TSH

+0.66 87 P6 SAI 01H

+0.84 109 P6 SAI 01H

-0.60 91 P6 SAI 02H

+0.92 78 P6 SAI 01H

-0.76 109 P6 SAI TSH

+0.44 108 P6 SAI 02H

+0.53 95 P6 SAI 01H

-0.70 99 P6 MAI 01H

+0.27 90 P6 SAI 02H

-0.18 99 P6 SAI 02H

+0.88 105 P6 MAI 03H

+0.70 77 P6 SAI 06H

+0.81 105 P6 SAI 02H

+0.80 103 P6 SAI 05H

+0.35 106 P6 SAI 01H

-0.30 103 P6 SAI 03H

+0.81 56 P6 SAI 01H

+0.23 49 P6 SAI 03H

+0.89 93 P6 SAI 01H

-0.32 02H 02H 05H 05H 01H 01H 01H 01H 01H 01H 01H 01H 01H 01H 02H 02H 02H 02H 03H 03H 02H 02H 02H 02H 01H 01H 01H 01H 01H 01H 02H 02H 02H 02H 02H 02H 03H 03H 03H 03H 03H 03H 01H 01H 01H 01H 01H 01H 02H 02H 02H 02H 03H 03H 02H 02H 07H 07H 01H 01H 02H 02H TSH TSH TSH TSH 01H 01H 01H 01H 02H 02H 01H 01H TSH TSH 02H 02H 01H 01H 01H 01H 02H 02H 02H 02H 03H 03H 06H 06H 02H 02H 05H 05H 01H 01H 03H 03H 01H 01H 03H 03H 01H 01H 61 HOT 61 HOT 61 HOT 61 HOT 61 HOT 61 HOT 68 HOT 53 HOT 61 HOT 61 HOT 92 HOT 107 HOT 53 HOT 53 HOT 53 HOT 53 HOT 61 HOT 61 HOT 61 HOT 61 HOT 61 HOT 68 HOT 88 HOT 88 HOT 92 HOT 92 HOT 107 HOT 53 HOT 61 HOT 88 HOT 92 HOT 30 HOT 29 HOT 94 HOT 88 HOT 88 HOT 53 HOT 29 HOT 61 HOT 61 HOT 61 HOT 107 HOT 107 HOT 92 HOT 53 HOT 92 HOT 53 HOT 92 HOT 92 HOT 61 HOT 61 HOT 61 HOT PROBE 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 15 of 92 Areva NP 6/7/2006 9:02 AM Component: S/G A Attachment I Customer Name: St. Lucie Unit 2 Page 10 of 13 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG 0.30 0.15 77 87 0.16 78 90 0.27 78 138 0.34 78 140 0.25 79 91 0.25 79 93 0.25 79 97 0.26 80 50 0.41 80 62 0.82 80 76 0.17 80 82 0.21 81 67 0.32 0.23 0.40 81 77 0.21 81 91 0.36 81 127 0.51 0.49 81 131 0.22 0.39 82 28 0.41 82 34 0.40 82 44 0.15 0.18 0.79 82 60 0.20 0.11 82 90 0.44 82 102 0.25 82 128 0.19 82 138 0.17 83 37 0.10 84 30 0.17 84 36 0.26 84 68 0.30 84 84 0.34 84 92 0.13 84 98 0.34 86 22 1.18 1.18 86 132 0.24 87 49 0.28 87 57 0.15 87 59 0.27 87 69 0.35 87 131 0.12 88 94 0.19 88 128 0.12 89 63 0.23 90 128 0.24 71 P6 SAI 72 P6 SAI 107 P6 SAI 104 P6 SAI 106 P6 SAI 98 P6 SAI 98 P6 SAI 78 P6 SAI 75 P6 SAI 96 P6 SAI 96 P6 SAI 104 P6 SAI 52 P6 SAI 78 P6 SAI 74 P6 SAI 82 P6 SAI 36 P6 SAI 107 P6 SAI 92 P6 SAI 92 P6 SAI 77 P6 SAI 92 P6 SAI 103 P6 SAI 270 P6 SAI 99 P6 SAI 66 P6 SAI 110 P2 TWD 35 113 P6 MAI 58 P6 SAI 104 P6 SAI 95 P6 SAI 98 P6 SAI 58 P6 SAI 62 P6 SAI 94 P6 SAI 88 P6 SAI 102 P6 SAI 72 P6 SAI 89 P6 SAI 81 P6 SAI 98 P2 TWD 37 93 P2 TWD 37 95 P6 SAI 96 P6 SAI 75 P6 SAI 102 P6 SAI 83 P6 SAI 123 P6 SAI 110 P6 SAI 75 P6 SAI 82 P6 SAI 99 P6 SAi 06H

+0.68 05H

+0.42 01H

+0.85 01H

+0.31 01H

-0.77 02H

+0.94 01H

-0.55 01H

+0.89 01H

-0.74 01H

-0.59 01H

-0.54 01H

+0.82 01H

-0.83 01H

-0.75 01H

-0.55 01H.

-0.12 02H

+0.74 01H

-0.44 01H

-0.56 02H

+0.76 01H

-0.73 01H

+0.52 03H

+0.48 01H

+0.62 02H

+0.85 03H

-0.30 06H 06H 61 05H 05H 103 01H 01H 61 01H 01H 61 01H 01H 88 02H 02H 88 01H 01H 61 01H 01H 61 01H 01H 61 01H 01H 53 01H 01H 61 01H 01H 61 01H 01H 61 01H 01H 110 01H 01H 110 01H. 01H 11.0.

02H 02H 103 01H 01H 103 01H 01H 83 02H 02H 83 01H 01H 83 01H 01H 83 03H 03H 107 01H 01H 107 02H 02H 108 03H 03H 108 TEH TEC 53 03H 03H 108 03H 03H 108 02H 02H 103 02H 02H 83 02H 02H 83 03H 03H 83 03H 03H 125 02H 02H 107 01H 01H 125 01H 01H 94 05H 05H 103 02H 02H 103 01H 01H 103 TEH TEC 54 TEH TEC 54 02H 02H 83 02H 02H 108 01H 01H 108 02H 02H 108 01H 01H 103 01H 01H 83 01H 01H 103 01H 01H 83 02H 02H 108 02H 02H 83 NOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 600UL 600UL 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P VS2 03H 03H 02H 02H 02H 03H 03H 02H 01H 01H 05H 02H 01H VS2 VS3 02H 02H 01H 02H 01H 01H 01H 01H 02H 02H

+0.75

+0.38

-0.28

+0.28

+0.23

+0.77

+0.88

+0.58

+0.84

+0.65

-0.72

+0.41

+0.75

-0.06

+0.84

-0.62

+0.97

+0.67

-0.24

+0.52

-0.45

+0.89

-0.50

+0.84

+0.73

+0.44

St. Lucie Unit 2 Docket Ns. 50-389 Areva NP L-2007-076 Attachment Page 16 of 92 6/7/2006 9:02 AM Component: S/G A Customer Name: St. Lucie Unit 2 Page 11 of 13 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS 91 37 0.18 91 41 0.17 0.22 92 86 1.01 92 92 0.18 92 98 0.31 93 59 0.42 93 69 0.15 93 83 0.35 93 91 0.33 93 111 0.22 93 133 0.58 93 141 0.15 94 112 0.17 95 63 0.27 95

125, 0.18 97 97 0.38 98 94 0.35 98 138 0.18 99 99 0.20 102 46 0.39 102 52 0.27 0.32 102 64 0.18 0.28 0.30 102 124 0.16 103 39 0.19 103 41 0.24 103 51 0.25 103 113 0.37 0.18 104 46 0.18 104 112 0.26 104 120 0.14 0.20 104 126 0.28 105 43 0.19 105 53 0.20 0.17 0.17 105 55 0.22 105 73 0.31 105 85 0.36 105 89 0.47 106 50 0.31 106 66 0.36 106 72 0.23 106 112 0.18 0.36 106 116 0.20 108 98 0.20 DEG 288 87 270 126 90 65 115 85 101 90 80 93 84 64 100 157 90 90 72 97 281 96 92 84 86 85 67 242 56 264 96 65 106 98 136 87 105 83 95 250 254 77 80 84 96 291 95 92 98 93 104 60 CHN P6 P6 P6 P2 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6&

P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 IND %TW LOCATION SAI 02H

+0.90 SAI 02H

-0.30 SAI 02H

+0.88 TWD 38 VS3

-0.87 SAI 02H

+0.77 SAI 04H

+0.71 MAI 01H

-0.38 SAI 02H

+0.69 MAI 04H

+0.75 SAI 01H

-0.23 SAI 01H

-0.80 SAI 02H

-0.65 SAI 01H

+0.82 SAI 02H

+0.91 SAI 02H

+0.81 SAI 03H

-0.19.

SAI 02H

-0.51 SAI 02H

+0.76 SAI 01H

+0.72 SAI 02H

+0.75 SAI 02H

+0.65 SAI 05H

+0.48 SAI 03H

+0.64 SAI 01H

-0.63 SAI 05H

+0.53 SAI 08H

+0.69 SAI 02H

+0.25 SAI 03H

-0.30 SAI 03H

+0.90 SAI 02H

+0.84 SAI 02H

-0.55 SAI 02H

+0.96 SAI 03H

+0.83 SAI 02H

+0.57 SAI 01H

-0.43 SAI 01H

+0.41 SAI 01H

-0.48 SAI 02H

-0.22 SAI 01H

-0.55 SAI 04H

+0.88 SAI 06H

+0.52 MAI 03H

+0.82 SAI 02H

+0.74 SAI 01H

-0.34 SAI 01H

-0.36 SAI 02H

+0.81 SAI 01H

+0.89 SAI 01H

-0.34 SAI 02H

-0.23 SAI 02H

+0.56 SAI 02H

+0.30 SAI 01H

-0.59 EXT 02H 02H 02H TEH 02H 04H 01H 02H 04H 01H 01H 02H 01H 02H 02H 03H 02H 02H 01H 02H 02H 05H 03H 01H 05H 08H 02H 03H 03H 02H 02H 021 03H 02H 01H 01H 01H 02H 01H 04H 06H 03H 02H 01H 01H 02H 01H 01H 02H 02H 02H 01H EXT 02H 02H 02H TEC 02H 04H 01H 02H 04H 01H 01H 02H 01H 02H 02H 03H_

02H 02H 01H 02H 02H 05H 03H 01H 05H 08H 02H 03H 03H 028 02H 02H 03H 02H 01H 01H 01H 02H 01H 04H 06H 03H 02H 01H 01H 02H 01H 01H 02H 02H 02H 01H CAL #

107 107 107 47 103 103 108 103 103 103 83 83 83 83 108 83-103 103 83 103 107 125 128 125 108 108 83 107 107 107 83 83 107 83 83 83 83 107 107 107 107 107 103 103 103 107 94 103 83 83 83 103 LEG HOT HOT HOT COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 5803P 5803P 5803P 600UL 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 17 of 92 Areva NP 6/7/2006 9:02 AM Component: S/G A Customer Name: St. Lucie Unit 2 Page 12 of 13 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG 109 53 0.24 109 67 0.23 109 71 0.21 110 54 0.29 0.17 0.10 0.37 0.22 110 62 0.22 0.16 0.22 110 72 0.22 0.12 110 104 0.25 110 112 0.33 110 124 0.14 111 67 0.13 i11 115 0.19 112 62 0.28 112 70 0.46 0.18 112 116 0.20 113 47 0.17 113 53 0.39 0.23 113 59 0.25 113 73 0.27 113 109 0.20 113 129 0.21 114 82 0.17 114 86 0.22 114 98 0.19 114 114 0.14 0.15 0.26 114 122 0.23 114 124 0.18 0.13 114 126 0.15 115 69 0.25 0.27 115 87 0.31 116 46 0.17 116 60 0.31 0.18 116 70 0.37 116 72 0.37 116 74 0.35 0.21 116 112 0.25 0.17 0.31 159 P6 SAI 83 P6 SAI 91 P6 SAI 117 P6 SAI 104 P6 SAI 140 P6 SAI 288 P6 SAI 113 P6 SAI 68 P6 SAI 68 P6 SAI 93 P6 SAI 76 P6 SAI 95 P6 SAI 84 P6 SAI 98 P6 SAI 109.P6 SAI 67 P6 MAI 99 P6 SAI 107 P6 SAI 91 P6 SAI 87 P6 SAI 91 P6 SAI 78 P6 SAI 266 P6 SAI 47 P6 SAI 84 P6 SAI 93 P6 SAI 136 P6 SAI 80 P6 SAI 90 P6 SAI 76 P6 MAI 120 P6 SAI 103 P6 SAI 65 P6 SAI 113 P6 MAI 100 P6 SAI 109 P6 SAI 89 P6 SAI 84 P6 SAI 72 P6 SAI 100 P6 SAI 108 P6 SAI 93 P6 SAi 98 P6 SAI 64 P6 SAI 92 P6 SAI 93 P6 SAI 99 P6 SAI 88 P6 SAI 72 P6 MAI 103 P6 SAI 105 P6 SAI 03H

-0.13 03H 03H 107 03H

+0.90 03H 03H 110 01H

-0.18 01H 01H 103 02H

-0.59 02H 02H 125 02H

+0.54 02H 02H 125 03H

-0.20 03H 03H 107 03H

+0.94 03H 03H 107 05H

-0.28 05H 05H 107 03H

+0.92 03H 03H 94 01H

+0.16 01H 01H 108 02H

+0.33 02H 02H 108 02H

-0.13 02H 02H 103 02H

+0.92 02H 02H 103 01H

-0.60 01H 01H 83 02H

+0.69 02H 02H 83 01H

-0.66 01H 01H 103 03H

-0.13 03H 03H 94 01H

+0.68 01H 01H 83 02H

+0.67 02H 02H 108 01H

-0.71 01H 01H 103 01H

+0.32 01H 01H 103 01H

+0.64 01H 01H 83 02H

-0.92 02H 02H 107 01H

+0.67 01H 01H 107 06H

+0.67 06H 06H 107 02H

+0.28 02H 02H 108 01H

-0.14 01H 01H 103 02H

-0.61 02H 02H 83 04H

+0.78 04H 04H 83 02H

+0.79 02H 02H 103 01H

+0.29 01H 01H 103 01H

-0.49 01H 01H 103 01H

-0.61 01H 01H 103 02H

-0.20 02H 02H 83 02H

+0.84 02H 02H 83 02H

-0.03 02H 02H 83 02H

-0.21 02H 02H 83 02H

+0.47 02H 02H 83 03H

+0.64 03H 03H 83 01H

-0.56 01H 01H 103 01H

+0.40 01H 01H 103 03H

-0.20 03H 03H 103 03H

+0.75 03H 03H 107 02H

+0.67 02H 02H 108 02H

-0.51 02H 02H 108 01H

-0.16 01H 01H 103 01H

+0.80 01H 01H 103 05H

+0.48 05H 05H 103 03H

+0.71 03H 03H 103 01H

+0.70 01H 01H 83 02H

-0.17 02H 02H 83 02H

+0.46 02H 02H 83 HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 58032 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P

St. Lucie Unit 2 Docket Ns. 50-389 Areva NP L-2007-076 Attachment Page 18 of 92 6/7/2006 9:02 AM Component: S/G A Customer Name:- St. Lucie Unit 2 Page 13 of 13 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS 118 66 0.30 118 70 0.22 0.20 118 116 0.21 120 82 0.29 121 89 0.32 121 97 0.27 122 116 0.21 123 51 0.25 124 74 0.26 124 78 0.35 0.15 0.28 124 80 0.20 0.13 0.18.

124 88 0.25 129 93 0.35 131 77 0.18 0.12 0.24 138 98 0.82 139 91 0.88 DEG 92 85 81 86 98 100 66 86 94 78 77 74 101 95 74 104-110 101 77 49 117 98 9

CHN P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P2 P2 IND %TW SAT SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI NAI SAI SAI SAI SAI TWD 36 TWD 37 LOCATION 01H

+0.76 02H

+0.17 02H

+0.61 02H

+0.71 01H

+0.62 03H

-0.33 02H

+0.63 01H

-0.76 02H

+0.71 01H

-0.53 03H

+0.81 03H

+0.02 01H

+0.65 01H

+0.50 01H

-0.06 03H

+0.78-01H

+0.46 01H

+0.31 03H

+0.73 05H

+0.67 01H

+0.76 DHT

+0.06 DCT

+0.24 EXT EXT 01H 01H 02H 02H 02H 02H 02H 02H 01H 01H 03H 03H 02H 02H 01H 01H 02H 02H 01H 01H 03H 03H 03H 03H 01H 01H 01H 01H 01H 01H 03H.03H-01H 01H 01H 01H 03H 03H 05H 05H 01H 01H TEH TEC TEH TEC CAL #

94 103 103 83 103 103 121 83 107 103 103 103 121 103 103 103.

103 103 135 125 128 57 57 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT,-

HOT HOT HOT HOT HOT COLD COLD PROBE 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P.

5803P 5803P 5803P 5803P 5803P 600UL 600UL Total Tubes

463 Total Records:

647

St. Lucie Unit 2 Docket Ns. 50-3 89 L-2007-076 Attachment Page 19 of 92 Areva NP 6/7/2006 9:03 AM Component: S/G A Customer Name: St.

Lucie Unit 2 Page 1 of 1 Tubes with Wear Indications >35% to 39% Preventively Plugged (PTP)

ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 35 69 37 69 38 96 42 70 42 72 49 79 49 87 51 77 51 79 53 77 56 86 61 79 62 80 82 44 86 22 92 86 138 98 139 91 0.88 0.91 1.08 0.90 0.82 0.93 0.99 0.97 1.45 1.12 1.14 0.79 0.81 0.79 1.18 1.18.

1.01 0.82 0.88 80 94 97 98 90 86 102 99 90 117 110 112 73 110 98 93 126 98 9

P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2.

P2 P2 P2 TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD T.WD TWD TWD TWD 35 35 35 35 36 38 37 38 37 35 36 36 36 35 37 37.

38 36 37 DCB DCB DCB DCB DHB VS3 DCT DCT DCT DHB DCB DCB DCB VS2 VS2 VS3.

VS3 DHT DCT

+0.67

+0.47

+0.00

+0.34

+0.00

+0.94

+0.00

+0.00

+0.00

+2.00

+0.00

+0.00

+0.00

+0.75

+0.84

-0.62-

-0.87

+0.06

+0.24 TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC.

TEC TEC TEC 43 43 3

43 6

6 4

6 5

5 3

6 6

53 54

.54, 47 57 57 COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD-COLD COLD COLD 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL Total Tubes 18 Total Records:

19 Note: The tube located at Row 82 Line 44 was plugged due to axial indications (SAI) at two eggcrate locations.

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 20 of 92 Areva NP 6/7/2006 9:05 AM Component: S/G A Customer Name: St. Lucie Unit 2 Page 1 of 7 Tubes with Bobbin 20-34% TWD Indications ROW LINE VOLTS 72 20 0.33 88 20 0.69 87 21 0.63 89 21 0.46 86 22 0.39 90 24 0.40 61 25 0.43 92 26 0.41 0.51 0.24 0.37 88 28 0.50 0.31 0.41 98 28 0.63 81 29 0.78 0.67 0.60 0.49 96 30 0.44 0.29 0.30 98 30 0.42 105 33 0.47 96 34 0.37 51 35 0.44 111 35 0.31 88 36 0.20 103 37 0.35 95 41 0.79 119 41 0.27 82 44 0.23 94 44 0.43 102 44 0.37 122 44 0.55 66 46 0.31 124 46 0.29 49 47 0.40 3

49 0.39 41 49 0.34 75 49 0.49 48 50 0.49 124 50 0.34 0.57 126 50 0.44 0.46 39 51 0.40 78 52 0.76 84 52 0.82 0.30 128 52 0.41 85 53 0.36 126 54 0.42 DEG 120 88 120 93 72 152 103 47 128 108 86 41 79 82 104 116 120..

118 58 5

153 125 50 97 144 126 55 149 20 12 73 113 51 50 113 94 65 119 60 103 120 113 104 129 108 109 148 132 95 126 44 66 151 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD T.WD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW LOCATION 25 VS2

-0.61 34 VS2

-0.97 30 VS2

+0.79 28 VS2

+0.66 23 VS3

+0.64 24 VS3

-0.82 29 VS4

+1.12 27 V$4

-0.85 30 VS4

+0.58 20 VS2

+0.77 25 05C

-0.89 30 Vs4

-0.30 23 VS3

-0.83 27 VS4

-0.77 30 VS4

+0.60 32 VS3

+0.62 30 VS3

-0.15.

29 VS4

-0.94 27 VS3

-0.97 28 DCT

+0.00 22 VS3

+0.85 23 VS2

+0.83 24 VS2

+0.51 28 Vs2

+0.21 25 VS2

-0.77 28 VS3

-0.91 22 07H

-0.99 22 VS4

+0.49 24 DCB

+0.00 33 DHT

+0.00 21 VSI

-0.64 20 VS3

-0.81 26 VS2

+0.79 25 DCB

+0.00 29 DCT

+0.00 20 03H

+1.05 22 DCT

+0.00 23 VS3

-0.98 24 02C

-0.67 21 VS3

-0.94 26 VS3

-0.68 25 VS3

-0.70 24 VS1

+0.69 30 VS2

-0.82 23 08H

-0.23 24 VS1

+0.78 23 VS3

+0.73 31 VS4

+0.83 34 VS3

+0.00 22 VS4

+0.58 22 DHT

-0.09 25 08H

+0.60 22 VS1

+0.82 EXT EXT TEC TEN TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEC TER TEH TEC TEN TEC TEN TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TER TEC TEN TEC TEN TEC TEN TEC TEN TEC TER TEC TEN TEC TEH TEC TEN TEC TEC TER TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TER TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC 07H TEC TEN TEC TEH TEC TEN TEC TEN TEC TEN TEC TER TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC CAL #

85 55 54 55 54 54 82 55 55 55 55 55 55 55 54 54 54 54 54 55 55 55 54 52 52 77 52 73 52 52 52 53 52 52 52 13 52 13 69 13 13 13 51 51 50 50 13 15 51 51 50 51 50 LEG HOT COLD COLD COLD COLD COLD HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 580SF 600UL 600UL 60OUL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 21 of 92 Areva NP 6/7/2006 9:05 AM Component: S/G A Customer Name: St. Lucie Unit 2 Page 2 of 7 Tubes with Bobbin 20-34% TWD Indications ROW LINE VOLTS 0.35 128 54 0.24 49 55 0.33 78 56 0.33 95 57 0.35 0.27 129 57 0.77 96 58 0.31 132 58 0.37 0.26 93 59 0.47 95 59 0.44 0.51 127 59 0.35 82 60 0.38 130 60 0.40 129 61 0.54 133 61 0.46 78 62 0.62 0.34 0.37 134 62 0.17 19 63 0.45 39 63 0.31 135 63 0.45 0.59 0.31 0.28 94 64 0.40 0.83 0.42 0.35 128 64 0.49 132 64 0.57 31 67 0.45 79 67 0.54 0.38 34 68 0.48 35 69 0.45 37 69 0.32 44 70 0.41 50 70 0.28 136 70 0.56 0.30 0.44 39 71 0.55 43 71 0.35 45 71 0.50 51 71 0.27 53 71

'0.37 42 72 0.59 44 72 0.66 50 72 0.37 DEG CHN 109 P2 106 P2 141 P2 97 P2 91 P2 94 P2 91 P2 60 P2 74 P2 149 P2 115 P2 137 P2 84 P2 124 P2 89 P2 151 P2 19 P2-56 P2 111 P2 139 P2 92 P2 120 P2 110 P2 126 P2 91 P2 45 P2 64 P2 63 P2 143 P2 69 P2 153 P2 25 P2 131 P2 80 P2 120 P2 99 P2 121 P2 119 P2 92 P2 98 P2 113 P2 124 P2 128 P2 94 P2 112 P2 115 P2 41 P2 127 P2 116 P2 145 P2 110 P2 131 P2 102 P2 IND %TW TWD 20 TWD 20 TWD 20 TWD 20 TWD 25 TWD 21 TWD 30 TWD 23 TWD 29 TWD 25 TWD 28 TWD 23 TWD 25 TWD 25 TWD 21 TWD 22 TWD-26 TWD 20 TWD 30 TWD 23 TWD 24 TWD 20 TWD 27 TWD 22 TWD 31 TWD 34 TWD 27 TWD 26 TWD 22 TWD 33 TWD 23 TWD 20 TWD 25 TWD 27 TWD 27 TWD 29 TWD 24 TWD 29 TWD 26 TWD 21 TWD 27 TWD 22 TWD 33 TWD 26 TWD 31 TWD 31 TWD 25 TWD 26 TWD 21 TWD 22 TWD 32 TWD 29 TWD 25 LOCATION VS1

-0.07 DHT

+0.00 VS3

-0.81 VS3

+0.67 VS2

+0.75 DHT

+0.00 DCT

+0.00 VS4

-0.06 DHB

+0.01 DCB

+0.00 VS4

+0.67 VS2

+0.87 VS3

+0.57 VS1

+0.84 VS3

-0.78 DHT

+0.00 DHT-...

+0.00 08H

-1.00 VS2

+0.68 VS3

-0.96 VS4

+0.51 08H

-0.99 VS3

-0.69 VS3

-0.90 09H

+0.93 VS1

-0.69 VS1

+0.83 DHB

+0.00 VS2

-0.93 VS2

+0.72 VS3

+0.85 VS4

+0.06 VS1

+0.68 DHT

+0.00 DCB

+0.00 VS4

+0.70 VS2

-0.83 DHB

+0.00 DHB

+0.25 DHB

+0.32 DCB

+0.00 VS3

-0.70 VS1

-0.84 VS2

+0.92 VS3

-0.73 DCB

+0.00 DCB

+0.00 DCB

+0.44 DCT

+0.00 DCT

+0.00 DCT

+0.00 DHB

+0.20 DCB

+0.00 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC-TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC CAL # LEG 50 COLD 51 COLD 15 COLD 15 COLD 51 COLD 51 COLD 50 COLD 51 COLD 57 COLD 57 COLD 51 COLD 50 COLD 50 COLD 51 COLD 48 COLD 50 COLD 50 COLD 57 COLD 17 COLD 17 COLD 17 COLD 57 COLD 17 COLD 17 COLD 57 COLD 57 COLD 57 COLD 57 COLD 48 COLD 48 COLD 48 COLD 48 COLD 48 COLD 56 COLD 17 COLD 17 COLD 17 COLD 18 COLD 43 COLD 43 COLD 6

COLD 6

COLD 57 COLD 57 COLD 57 COLD 6

COLD 6

COLD 5

COLD 6

COLD 5

COLD 6

COLD 5

COLD 6

COLD PROBE 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 22 of 92 Areva NP 6/7/2006 9:05 AM Component: S/G A Customer Name: St. Lucie Unit 2 Page 3 of 7 Tubes with Bobbin 20-34% TWD Indications ROW LINE VOLTS 126 72 0.50 134 72 0.32 43 73 0.52 0.34 49 73 0.43 51 73 0.37 53 73 0.29 55 73 0.40 75 73 0.37 133 73 0.18 135 73 0.67 0.51 1.13 46 74 0.39 48 74 0.40 54 74 0.31 56 74 0.36 82 74 0.54 45 75 0.48 0.42 57 75 0.30 93 75 0.32 133 75 0.25 46 76 0.68 0.66 0.50 48 76 0.57 0.41 58 76 0.28 53 77 0.65 57 77 0.74 73 77 0.25 93 77 0.35 48 78 0.35 0.50 56 78 0.97 96 78 0.59 49 79 0.71 0.65 0.67 51 79 0.58 53 79 0.37 0.29 53 81 0.93 0.51 59 81 0.28 50 82 0.60 0.37 60 82 0.76 51 83 0.71 0.39 85 83 0.34 135 83 0.21 DEG 123 105 77 68 128 67 63 152 135 112 81 48 130 90 ill 153 139 118 88 128 136 157 113 94 40 114 119 95 115 121 121 136 112 23 132 77 71 110 72 53 98 124 85 68 51 115 73 ill 96 101 89 115 134 CHN P2 22 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW 25 27 26 21 27 22 22 23 22 20 28 25 34 26 23 23 22 26 29 27 23 24 24 34 33 30 27 23 22 29 30 20 21 21 25 33 28 34 33 34 27 25 22 33 26 22 28 22 30 30 22 23 22 LOCATION 08H

+0.89 VS1

+0.81 DHB

+0.26 DCB

-0.07 DCB

+0.00 DCB

+0.22 DCB

+0.00 DCB

+0.15 VS3

+0.70 VS1

-0.75 VS1

+0.79 VS3

+0.69 VS4

+0.79 DHB

+0.00 DCT

-0.24 DCT

+0.00 VS3

+0.78 VS2-

-1.02 DHT

+0.00 DCT

+0.00 VS3

-0.80 VS2

-0.88 VS1

+0.68 DHB

+0.00 DHT

+0.00 DCT

+0.00 DHB

+0.11 DCB

-0.17 DCB

+0.00 DCT

-0.24 DCT

-0.02 VS2

-0.97 DCB

+0.74 DHB

-0.09 DCT

-0.17 DCB

+0.00 VS3

-1.07 DCT

+0.00 DHT

+0.00 VS3

-0.17 DHT

+0.00 DCT

+0.00 DHT

+0.00 DCT

-0.04 DHB

-0.15 DCB

+0.00 DCB

+0.22 DHB

+2.00 DHB

+0.08 DHB

+0.20 DCB

+0.20 VS2

-1.02 VS1

-0.81 EXT TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH EXT TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC CAL #

44 57 5

5 6

5 6

5 5

57 56 56 56 6

5 6

5 44 6

6 6

45 57 6

6 6

5 5

6 5

5 6

44 5

5 5

44 6

6 6

5 6

6 5

5 6

5 5

5 5

5 46 57 LEG PROBE COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL

St. Lucie Unit 2 Docket Ns. 50-3 89 L-2007-076 Attachment Page 23 of 92 Areva NP 6/7/2006 9:05 AM Component: S/G A Customer Name: St. Lucie Unit 2 Page 4 of 7 Tubes with Bobbin 20-34% TWD Indications ROW LINE VOLTS 52 84 0.78 56 84 0.49 61 85 0.34 77 85 0.27 54 86 0.46 0.27 0.34 58 86 0.88 60 86 0.26 62 86 0.42 92 86 0.28 0.45 49 87 0.31 51 87 0.59 0.92 55 87 0.37 0.52 0.42 57 87 0.68 59 87 0.37 93 87 0.45 0.37 97 87 0.36 50 88 0.79 0.90 52 88 0.33 0.36 54 88 0.29 56 88 0.36 94 88 0.46 0.50 49 89 0.29 53 89 0.52 83 89 0.27 0.32 95 89 0.44 0.26 0.40 46 90 0.34 0.42 48 90 0.37 0.36 50 90 0.37 82 90 0.29 45 91 0.75 0.77 0.62 47 91 0.45 51 91 0.27 57 91 0.29 139 91 0.30 0.57 56 92 0.57 DEG 106 68 96 145 128 89 103 127 101 148 160 136 97 137 53 143 96 80 ill 101 127 34 129 71 79 157 70 142 151 147 130 124 120 146 113 123 97 97 167 134 115 137 82 120 157 16 96 61 95 113 140 56 29 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWD 30 TWD 25 TWD 23 TWD 20 TWD 28 TWD 20 TWD 24 TWD 33 TWD 20 TWD 25 TWD 20 TWD 27 TWD 22 TWD 29 TWD 34 TWD 25 TWD 29 TWO 26 TWD 31 TWD 25 TWD 27 TWD 24 TWD 24 TWD 32 TWD 34 TWD 23 TWD 24 TWD 21 TWD 24 TWD 27 TWD 28 TWD 22 TWD 29 TWD 20 TWD 22 TWD 26 TWD 20 TWD 25 TWD 23 TWD 26 TWD 24 TWO 23 TWD 25 TWD 21 TWD 34 TWD 34 TWD 31 TWD 26 TWD 21 TWO 21 TWD 26 TWD 33 TWD 30 LOCATION DCT

-0.23 DCB

-0.04 DCB

+0.00 VS4

+0.82 VS3

-0.69 VS3

+0.84 DHB

+0.00 DCB

+0.00 DHB

+0.00 DCB

+0.00 VS4

-0.97 VS2

+0.85 DHB

+0.00 DHB

+0.00 DCT

+0.00 VS3

-0.80 DHB

+0.00 DCT'

+0.00 DCB

+0.00 DHB

+0.00 VS2

+0.87 VS2

-0.90 VS2

-0.78 DHT

+0.00 DCB

+0.00 DCT

+0.00 DCB

+0.00 DCB

+0.00 DCT

+0.00 VS4

+0.65 VS2

-0.93 DCB

+0.00 DHB

+0.00 VS4

-0.76 VS3

+0.78 VS4

-0.84 VS2

-1.07 VS2

+0.50 DHT

+0.00 DCT

+0.00 DCB

+0.00 DCT

+0.00 DCB

+0.00 VS3

-0.80 DHT

+0.00 DCT

+0.00 DHB

+0.00 DHB

+0.00 DHB

+0.00 DHB

+0.00 VS5

+0.70 DHT

+0.24 DHT

+0.00 EXT TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEN TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH EXT TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC CAL 5

5 4

4 4

4 4

3 4

3 47 47 4

3 3

4 4

4 3

4 47 47 47 3

3 4

4 3

4 46 46 4

4 46 46 46 46 46 4

4 3

3 4

46 4

4 4

3 4

3 57 57 4

  1. LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 60O0UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UDL 600UL 600UL 600UL 600UL 600UL 600UL 600DL 600UL 600UL 600UL 600UL 600UL 600UL 600OL 600UL 600UL 600UL 600UL 600UL 600UL 600UL

St. Lucie Unit 2 Docket Ns. 50-3 89 L-2007-076 Attachment Page 24 of 92 Areva NP 6/7/2006 9:05 AM Component: S/G A Customer Name: St. Lucie Unit 2 Page 5 of 7 Tubes with Bobbin 20-34% TNqD Indications ROW LINE VOLTS 58 92 0.36 132 92 0.36 43 93 0.33 0.28 0.50 45 93 0.39 97 93 0.74 44 94 0.49 49 95 0.47 0.31 0.67 135 95 0.34 38 96 0.45 0.38 42 96 0.56 48 96 0.41 0.32 54 96 0.33 94 96 0.87 0.60 43 97 0.31 45 97 0.29 47 97 0.56 0.44 135 97 0.78 0.87 42 98 0.29 50 98 0.31 134 98 0.39 37 99 0.39 45 99 0.32 137 99 0.30 46 100 0.41 0.17 50 100 0.21 54 100 0.46 78 100 0.17 41 101 0.32 137 101 0.48 0.23 40 102 0.22 48 102 0.25 92 102 0.23 134 102 0.71 91 103 0.31 129 103 0.35 95 105 0.60 126 106 0.34 53 107 0.31 96 108 0.65 0.91 0.49 0.38 DEG 100 158 156 37 132 63 125 ill 128 141 113 153 55 124 80 124 119 113 113 84 139 97 129 111 60 78 110 135 72 101 101 47 61 135 153 108 58 150 35 138 162 68 42 138 128 26 102 106 71 104 91 151 141 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWO 23 TWD 21 TWD 23 TWD 21 TWD 29 TWD 24 TWD 32 TWD 27 TWD 27 TWD 21 TWD 31 TWD 20 TWD 26 TWD 24 TWD 30 TWD 25 TWD 22 TWD 23' TWD 33 TWD 28 TWD 22 TWD 21 TWD 29 TWD 26 TWD 30 TWD 31 TWD 22 TWD 22 TWD 30 TWO 26 TWD 23 TWD 27 TWD 30 TWD 20 TWD 22 TWD 31 TWD 20 TWD 20 TWD 32 TWD 23 TWD 23 TWD 24 TWD 20 TWD 29 TWD 24 TWD 25 TWD 32 TWD 21 TWD 20 TWD 28 TWD 32 TWD 25 TWD 22 LOCATION DCB

+0.00 VS1

+0.98 DHB

+0.00 VS3

+0.73 DCB

+0.00 DCB

+0.00 VS3

+0.83 DHB

+0.00 VS3

-0.65 VS3

+1.07 DCT

+0.00 VS1

-0.94 DHT

+0.00 DCT

+0.00 DHT

+0.00 VS3

-0.91 VS3

+0.71 VS3

-0.94 VS2

-0.98 VS4

+0.93 DCB

+0.00 DCT

+0.00 VS3

+0.85 DCB

+0.00 VS1

-0.81 VS3

+0.94 DCB

+0.39 VS3

-0.98 VS3

-0.34 DCB

+0.00 vS3

+0.60 VS5

-0.83 VS3

+0.70 VS3

-0.83 VS3

-0.80 VS3

+0.77 VS2

-0.07 DCT

+0.00 09H

+0.93 DHT

+0.23 VS3

-0.94 DCB

+0_13 VS2

+0.76 DCT

+0.00 VS4

-0.98 VS5

-0.90 VS3

+0.72 VSI

-0.89 VS3

+0.71 VS2

-0.74 VS3

-0.70 V34

+0.68 VS2

+0.76 EXT EXT CAL TEN TEC 3

TEH TEC 56 TEH TEC 4

TEH TEC 4

TEH TEC 4

TEH TEC 3

TEH TEC 46 TEH TEC 3

TEH TEC 3

TEH TEC 3

TEH TEC 3

TEH TEC 56 TEH TEC 3

TEH TEC 3

TEH TEC 4

TEH TEC 3

TEH TEC 3

TEH TEC 4

TEH TEC 48 TEH TEC 48 TEH TEC 3

TEH TEC 4

TEH TEC 3

TEH TEC 3

TEH TEC 56 TEH TEC 56 TEH TEC 4

TEH TEC 4

TEH TEC 57 TEH TEC 4

TEH TEC 4

TEH TEC 57 TEH TEC 8

TEH TEC 8

TEH TEC 8

TEH TEC 8

TEH TEC 8

TEH TEC 7

TEH TEC 57 TEH TEC 57 TEH TEC 8

TEH TEC 8

TEH TEC 41 TEH TEC 56 TEH TEC 41 TEH TEC 41 TEH TEC 41 TEH TEC 39 TEH TEC 7

TEH TEC 39 TEH TEC 39 TEH TEC 39 TEH TEC 39

  1. LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600OUL 600UL 600UL 600UL 600UL 600UL 600OUL 600UL 60OUL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600OL 600UL 600UL 60CUL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 60OUL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 25 of 92 Areva NP 6/7/2006 9:05 AM Component:

S/G A Customer Name: St. Lucie Unit 2 Page 6 of 7 Tubes with Bobbin 20-34% TWD Indications ROW 132 129 133 121 82 88 51 123 84 47 92 94 127 86 51 84 94 102 126 97 125 42 94 53 97 54 53 89 93 92 57 93 97 50 96 42 96 53 97 48 85 87 52 56 47 LINE VOLTS 108 0.36 109 0.31 109 0.19 0.23 111 0.29 112 0.33 0.46 112 0.30 113 0.32 113 0.34 0.36 0.42 114 0.32 115 0.58 116 0.24 116 0.32 117 0.21 118 0.41 119 0.24 120 0.25 120 0.75 0.33 0.34 120 0.30 120 0.22 121 0.51 121 0.44 124 0.33 126 0.26 127 0.63 127 0.49 128 0.55 129 0.24 129 0.34 131 0.81 132 0.29 133 0.41 133 0.30 133 0.47 0.25 134 0.41 134 0.38 138 0.43 138 0.57 139 0.40 139 0.46 140 0.38 141 0.33 143 0.34 0.56 146 0.34 152 0.68 155 0.27 DEG 46 142 85 145 139 114 148 153 127 36 137 132 84 134 146 45 125 115 152 139 100 138 82 143 12 101 42 140 78 46 59 127 159 88 46 55 102 161 90 117 146 63 106 102 132 72 123 104 30 98 133 106 154 CHN IND %TW P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD 21 21 21 23 20 21 25 20 20 21 22 24 21 22 21 20 20 26 20 23 32 24 24 23 21 28 29 25 21 23 26 22 20 20 31 22 23 23 28 20 23 22 26 27 25 24 22 20 21 27 20 32 20 LOCATION DCB

+0.00 VS1

-1.02 07C

-1.00 DHT

+0.24 08C

-0.79 VS2

+0.00 VS4

+0.62 VS3

-0.89 VS3

+0.81 VS1

-0.70 VS3

+0.74 VS4

+0.79 VS4

-0.91 VS3

-0.81 VS2

-0.79 VS4

-0.85 VS1

+0.73 VS3

-0.74 VS3

+0.81 VS4

-0.83 VS2

+0.62 VS3

-0.88 VS4

-0.90 VS3

-0.77 08H

-0.91' 08C

+0.88 DCT

+0.00 VS3

-0.85 VS2

-0.91 VS3

-0.82 VS3

+0.64 VS3

-0.97 VS3

-0.92 VS2

+0.93 VS2

+0.78 VS2

+0.72 VS3

+0.69 VS2

+0.49 VS2

-0.74 VS4

-0.78 DCT

+0.06 VS3

-0.87 05H

+0.85 VS3

-0.60 VS3

-0.83 VS2

-0.96 VS3

+0.84 VS3

+0.70 VS2

-0.98 VS3

+0.38 VS3

+0.75 VS3

-0.89 VS3

-0.77 EXT EXT TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC CAL #

56 58 57 57 58 37 37 37 5

37 37 37 37 9

38 37 35 36 10 35 36 36 36 36 35 36 35 10 36 9

34 9

10 32 32 33 22 33 33 33 22 32 23 32 23 32 25 32 32 32 25 28 28 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 6001L 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600ULL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 6000L 600UL 600UL 600UL 600UL

St. Lucie Unit 2 Docket Ns. 50-3 89 L-2007-076 Attachment Page 26 of 92 Areva NP 6/7/2006 9:05 AM Component: S/G A Customer Name: St. Lucie Unit 2 Page 7 of 7 Tubes with Bobbin 20-34% TWD Indications ROW LINE VOLTS 57 44 51 2

155 156 157 166 0.36 0.36 0.68 0.47 0.33 DEG 125 113 93 124 140 CHN P2 P2 P2 P2 P2 IND TW:

TWD TWD TWD TWO

%TW 21 21 30 25 22 LOCATION VS3

+1.02 VS3

-0.94 VS3

-0.54 VS3

+0.93 01C

-0.83 EXT TEH TEH TEH TEH 07C EXT TEC TEC TEC TEC TEC CAL #

29 29 29 29 20 LEG COLD COLD COLD COLD COLD PROBE 600 UL 600UL 600UL 600UL 60OUL Total Tubes

240 Total Records: 323

St. Lucie Unit 2 Docket Ns. 50-389 Areva NP L-2007-076 Attachment Page 27 of 92 6/7/2006 9:07 AM Component: S/G A Customer Name: St. Lucie Unit 2 Paqe 1 of 9 Tubes with Bobbin 1-19% TWD Indications ROW LINE VOLTS DEG CHN IND

%TW LOCATION EXT EXT CAL #

LEG PROBE 5

8 9

14 15 16 20 20 21 24 24 24 24 27 27 27 29 29 30 31 32 32 33 33 35 35 36 36 37 37 37 37 37 38 38 38 38 38 38 39 39 39 40 40 40 41 41 41 41 35 110 41 166 165 4

64 166 127 58 60 62 64 5

65 165 163 165 164 113 106 164 67 ill 5

69 62 164 27 67 119 121 125 66 96 100 124 126 162 99 109 123 40 70 118 15 61 71 97 0.11 0.34 0.14 0.20 0.17 0.09 0.20 0.18 0.16 0.17 0.24 0.21 0.09 0.11 0.26 0.26 0.15 0.20 0.22 0.12 0.21 0.13 0.21 0.22 0.25 0.19 0.23 0.13 0.11 0.13 0.13 0.14 0.26 0.16 0.20 0.16 0.21 0.09 0.34 0.34 0.20 0.31 0.07 0.19 0.18 0.24 0.22 0.23 0.11 0.12 0.29 0.24 0.20 16 P2 151 P2 15 P2 63 P2 151 P2 28 P2 86 P2 137 P2 41 P2 166 P2 29 P2 159 P2 147 P2 153 P2 129 P2 144 P2 15.8 P2 143 P2 144 P2 172 P2 114 P2 154 P2 158 P2 104 P2 69 P2 159 P2 98 P2 150 P2 170 P2 61 P2 81 P2 145 P2 40 P2 150 P2 140 P2 159 P2 110 P2 87 P2 94 P2 103 P2 149 P2 98 P2 158 P2 129 P2 166 P2 85 P2 113 P2 141 P2 63 P2 51 P2 151 P2 36 P2 28 P2 TWD 7 TWD 13 TWD 10 TWD 13 TWD 11 TWD 9 TWD 17 TWD 15 TWD 12 TWD 13 TWD 17 TWD 17 TWD 8 TWD 12 TWD 19 TWD 18 TWD 13 TWD 16 TWD 17 TWD 9 TWD 15 TWD 17 TWD 17 TWD 18 TWD 17 TWD 17 TWD 17 TWD 12 TWD 10 TWD 14 TWD 12 TWD 13 TWD 13 TWD 15 TWD 11 TWD 13 TWD 17 TWD 8 TWD 16 TWD 16 TWD 16 TWD 19 TWD 7 TWD 10 TWD 13 TWD 18 TWD 17 TWO 12 TWD 12 TWD 10 TWD 19 TWD 19 TWD 17 04H 06H 04H CiC 01H 05H VS3 01H VS3 VS3 VS3 VS3 VS3 01H DHB 01C 01C.

01H 01C 01H VS3 VS3 01C DCB VS3 01H DHT VS3 01H VS3 VS3 DCB VS3 VS3 VS3 VS3 DHB VS3 VS3 VS3 01H DCB VS3 VS3 VS3 DHB DCT VS3 VS3 VS3 DCB DHB DCB

+0.95

+0.96

+0.90

-0.78

-0.92

-0.97

-0.86

+0.91

+0.82

-0.93

-0.73

+0.86

-0.73

+0.81

+0.00

-1.05

-0.98

-1 03

-0.91

-0.97

-0.75

+0.79

+0.86

+0.00

+0.85

-1.00

-0.18

-0.94

+0.87

-0.77

+0.73

+0.00

+0.85

+0.80

+0.09

+0.71

+0.00

+0.80

+0.82

+0.93

+0.87

+0.00

+0.80

+1.06

+0.59

+0.43

-0.25

+0.91

+0.90

-0.83

+0.57

+0.00

+0.00 TER TEC TEN TEC TEN TEC TEN TEC TEH TEC TEC TEH TER TEC TEN TEC TEH TEC TEN TEC TEN TEC TEH TEC TER TEC TEC TEN TEH TEC TEH TEC TEN TEC-TEN TEC TEN TEC TEN TEC TEN TEC TER TEC TER TEC TEH TEC TEN TEC TEC TEN TEN TEC TEN TEC TEN TEC TEC TEH TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEC TEN TEN TEC TEN TEC TEN TEC TEN TEC COLD COLD COLD COLD COLD HOT COLD COLD COLD COLD COLD COLD COLD HOT COLD COLD COLD-COLD COLD COLD COLD COLD COLD COLD COLD HOT COLD COLD COLD HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT COLD COLD COLD COLD 600UL 600UL 600UL 60OUL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL.

600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 60OUL 600UL 60OUL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 60OUL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 28 of 92 Areva NP 6/7/2006 9:07 AM Component: S/G A Customer Name: St.

Lucie Unit 2 Page 2 of 9 Tubes with Bobbin 1-19% TWD Indications ROW LINE VOLTS 41 115 0.18 41 117 0.14 41 125 0.26 41 127 0.18 42 70 0.11 0.16 0.12 42 72 0.19 0.14 42 96 0.21 42 108 0.06 42 130 0.15 42 134 0.09 43 41 0.36 43 59 0.30 43 73 0.25 43 95 0.13 43 97 0.25 0.10 43 99 0.29 44 42 0.20 0.22 44 62 0.13 44 94 0.15 44 96 0.23 44 124 0.13 44 126 0.36 44 128 0.29 45 75 0.22 0.21 45 93 0.13 45 97 0.10 0.18 45 111 0.23 45 129 0.19 45 133 0.19 46 52 0.29 46 72 0.15 46 90 0.22 46 112 0.26 46 138 0.18 46 146 0.10 47 31 0.08 47 65 0.25 47 75 0.18 47 93 0.28 47 105 0.20 0.21 47 115 0.36 47 125 0.18 48 50 0.13 48 72 0.25 0.23 DEG 155 161 62 150 38 105 77 138 127 157 8

110 69 145 146 157 81 117 160 41 39 123 99 110 108 150 142 120 125 132 157 155 29 70 66 107 60 106 144 36 160 53 172 144 113 114 77 14 89 67 16 130 137 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW LOCATION TWD 10 VS3

+0.88 TWD 13 VS3

+0.93 TWD 13 VS3

-0.72 TWD 17 VS3

-0.86 TWD 10 DCT

-0.25 TWD 13 VS3

-0.11 TWD 11 VS3

+0.24 TWD 17 VS3

-0.82 TWD 14 VS3

+0.52 TWD 18 VS3

-0.97 TWD 6 VS3

+0.11 TWD 10 VS3

-0.90 TWD 4 VS3

-0.81 TWD 19 VS3

+0.84 TWD 19 VS3

-0.90 TWD 17 DHT

-0.20 TWD 13 VS3

+0.77 TWD 19 DCT

+0.00 TWD 10 VS3

+0.87 TWD 18 DHB

+0.00 TWD 11 VS3

+0.06 TWD 12 VS3

+0.67 TWD 11 VS3

+0.60 TWD 13 DCB

+0.00 TWD 18 DCT

+0.00 TWD 7 06C

+0.93 TWD 17 VS3

-0.74 TWD 14 VS3

+1.02 TWD 18 DHB

+0.00 TWD 18 DCB

+0.00 TWD 9 VS3

+0.98 TWD 10 VS3

+0.56 TWD 16 DCB

+0.00 TWD 16 VS3

+0.88 TWD 10 VS3

-0.69 TWD 12 VS3

+0.75 TWD 18 VS3

-0.99 TWD 14 DCB

+0.00 TWD 18 DCB

+0.00 TWD 18 VS3

+0.68 TWD 15 VS3

-0.63 TWD 11 VS3

+0.58 TWD 9 DHT

+0.00 TWD 19 VS3

-0.78 TWD 14 DHB

+0.00 TWD 17 DHB

+0.00 TWD 15 VS3

-0.85 TWD 16 VS3

+0.24 TWO 17 VS3

+0.91 TWD 10 VS3

+0.91 TWD 10 VS3

+0.11 TWD 17 VS3

+0.61 TWD 16 DCT

+0.04 EXT TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH EXT TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC CAL #

9 10 9

10 43 43 43 6

6 4

7 21 22 12 15 5

4 3

3 3

12 12 17 3

3 9

9 9

6 6

3 4

4 7

9 22 15 6

4 5

23 26 78 18 5

3 7

7 9

9 13 5

5 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 60OUL 60OUL 600UL 60OUL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 29 of 92 Areva NP 6/7/2006 9:07 AM Component: S/G A Customer Name: St. Lucie Unit 2 Page 3 of 9 Tubes with Bobbin 1-19% TWD Indications ROW LINE VOLTS 48 78 0.15 0.19 48 90 0.08 48 94 0.11 48 98 0.10 48 100 0.29 48 108 0.17 48 134 0.09 49 73 0.21 49 75 0.15 49 145 0.09 49 147 0.30 49 161 0.19 50 62 0.19 50 70 0.18 50 88 0.11 50 90 0.17 51 15 0.14 51 55 0.06 51 83 0.28 51 87 0.14 51 89 0.14 0.13 51 95 0.13 51 97 0.24 51 101 0.18 52 66 0.09 52 72 0.23 52 74 0.24 52 78 0.30 52 88 0.16 52 94 0.22 53 71 0.19 53 81 0.31 0.21 53 89 0.21 53 95 0.14 53 113 0.27 53 117 0.15 53 119 0.18 53 123 0.24 53 139 0.24 53 151 0.21 54 72 0.17 54 74 0.16 54 86 0.21 54 90 0.22 0.15 54 100 0.15 54 116 0.16 54 126 0.11 55 9

0.19 55 73 0.27 DEG CHN 154 P2 144 P2 12 P2 149 P2 28 P2 46 P2 161 P2 155 P2 108 P2 114 P2 157 P2 93 P2 164 P2 145 P2 78 P2 71 P2 146 P2 115 P2 19 P2 72 P2 134 P2 50 P2 130 P2 26 P2 159 P2 63 P2 160 P2 147 P2 99 P2 86 P2 36 P2 139 P2 65 P2 126 P2 142 P2 121 P2 87 P2 100 P2 147 P2 159 P2 53 P2 41 P2 151 P2 161 P2 119 P2 134 P2 106 P2 43 P2 94 P2 150 P2 148 P2 21 P2 137 P2 IND %TW LOCATION TWD 12 DHT

-0.24 TWD 14 DCB

+0.00 TWD 8 VS3

-0.48 TWD 10 VS3

-0.80 TWD 10 DHB

+0.09 TWD 19 DCB

+0.00 TWD 19 VS3

-0.83 TWD 6 06C

-0.56 TWD 18 DCT

+0.00 TWD 14 DHB

+0.00 TWD 12 VS3

+1.01 TWD 18 DCB

+0.13 TWD 14 VS3

-0.99 TWD 16 VS3

-0.83 TWD 16 DCB

+0.00 TWD 10 DCT

+0.00 TWD 15 05H.

+0.93 TWD 14 DHT

+0.00 TWD 8 07C

-0.19 TWD 18 DCT

+0.00 TWD 13 DCB

+0.00 TWD 13 DCB

+0.00 TWD 12 DHB

+0.00 TWD 12 DCB

+0.00 TWD 15 DHB

+0.29 TWD 14 VS3

+0.73 TWD 9

VS3

-0.92 TWD 16 DCT

-0.15 TWD 17 DCT

-0.24 TWD 19 DHB

+0.22 TWD 15 VS3

+0.71 TWD 17 VS3

-0.91 TWD 14 DCB

+0.00 TWD 18 DHT

+0.00 TWD 15 VS3

-0.15 TWD 18 DCT

+0.00 TWD 13 DCB

+0.00 TWD 18 VS3

+0.96 TWD 8 VS3

+1.00 TWD 10 VS3

+0.78 TWD 17 VS3

+0.79 TWD 19 VS3

+0.62 TWD 17 VS3

-0.92 TWD 15 VS3

+0.75 TWD 15 VS3

-0.87 TWD 18 DCT

+0.00 TWD 18 VS3

-0.98 TWD 14 DCB

+0.00 TWD 18 DHT

+0.00 TWD 15 VS3

-1.09 TWD 11 VS3

-0.86 TWD 17 01H

-0.93 TWD 18 VS3

-0.11 EXT TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TE H TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEH EXT TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEN TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEC CAL 5

5 3

3 3

7 8

21 6

6 26 25 31 18 6

3 4

84 16 5

3 3

3 4

3 7

18 5

5 5

4 3

5 5

5 4

3 5

9 9

5 23 28 6

6 4

4 4

8 10 10 87 5

  1. LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD
COLD, COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT COLD PROBE 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 30 of 92 Areva NP 6/7/2006 9:07 AM Component:

S/G A Customer Name:

St. Lucie Unit 2 Page 4 of 9 Tubes with Bobbin 1-19% TWD Indications ROW LINE VOLTS 55 87 0.15 55 93 0.19 56 78 0.22 56 82 0.26 0.20 56 90 0.17 57 67 0.10 57 89 0.15 57 93 0.14 57 97 0.11 57 99 0.18 0.19 57 127 0.36 57 147 0.14 58 38 0.10 59 81 0.21 60 78 0.27 0.17 60 82 0.13 61 51 0.11 61 81 0.23 61 83 0.16 62 74 0.16 62 86 0.25 62 118 0.24 63 41 0.28 0.08 63 79 0.19 63 93 0.04 0.12 64 44 0.07 64 68 0.21 64 72 0.24 64 98 0.26 66 142 0.12 72 24 0.16 73 77 0.16 74 16 0.12 75 41 0.10 75 43 0.26 0.24 75 49 0.28 75 85 0.18 76 84 0.16 76 116 0.18 0.20 77 51 0.13 77 117 0.29 78 52 0.18 78 56 0.19 78 110 0.12 78 148 0.11 79 63 0.15 DEG 158 145 112 42 150 74 162 150 170 147 145 34 72 34 157 139 90 114 55 66 124 140 58 135 141 134 62 85 84 28 161 109 145 62 156 146 147 26 52 123 99 108 90 152 106 144 160 134 139 103 164 39 132 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW 14 17 16 18 14 15 9

14 10 11 13 13 17 10 8

18 18.

13 10 12 16 12 15 19 12 16 11 14 4

11 8

16 17 17 9

17 15 13 8

18 16 18 15 15 10 11 14 14 13 14 11 13 12 LOCATION DCB

+0.00 DCB

+0.00 VS3

+0.04 DCT

-0.17 VS3 83 DHB

+0.00 VS3

+0.85 04H

+0.93 VS3

-0.69 VS3

+0.57 VS3

-0.74 VS3

+0.57 VS3

-0.26 VS3

+0.79 04H

+0.89 DHB

+0.08 VS3

+0.79 VS4

+0.00 DCB

+0.00 VS2

-0.31 DCB

+0.00 DCB

+0.14 VS4

-0.85 VS3

-0.74 VS3

+0.99 VS2

+0.62 VS3

-0.68 DCB

+0.00 03H

+0.19 03H

+0.77 VS3

+0.96 VS3

+0.70 VS4

-0.92 VS4

-0.74 VS2

+0.87 VS4

-0.85 VS2

+0.55 VS2

+0.85 VS2

-1.04 VS2

+0.83 VS4

-1.03 VS2

-0.82 VS3

+0.78 VS3

+0.81 VS3

+0.83 08C

+0.89 VS4

+0.79 VS3

+1.00 VS4

-0.66 VS4

+0.91 06H

+0.98 05C

-0.19 VS2

+0.73 EXT TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEH TEC TEH TEH TEH TEH TEH TEH TEN TEH TEN TEH TEH TEH TEH TEH TEH EXT TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEC TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC CAL #

4 4

5 5

5 3

18 4

3 3

3 3

9 25 11 6

5 5

5 14 5

5 6

3 9

12 12 5

3 3

14 17 5

3 25 82 6

84 11 13 13 13 3

4 9

9 14 9

15 15 8

26 17 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT COLD HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 600UL 60OUL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 60OUL 60OUL 60OUL 600UL 600UL 600UL 600OUL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 31 of 92 Areva NP 6/7/2006 9:07 AM Component: S/G A Customer Name: St. Lucie Unit 2 Page 5 of 9 Tubes with Bobbin 1-19% TWD Indications ROW LINE VOLTS 0.25 0.15 79 77 0.26 79 127 0.30 80 68 0.15 80 128 0.31 81 29 0.16 81 139 0.24 81 143 0.12 0.25 82 70 0.15 82 72 0.18 82 94 0.24 0.19 82 106 0.25 82 112 0.22 83 57 0.20 83 73 0.23 83 89 0.23 0.23 84 52 0.17 84 70 0.15 84 120 0.19 85 21 0.11 85 39 0.15 85 83 0.12 85 141 0.20 85 147 0.17 86 20 0.18 86 22 0.23 86 24 0.15 86 94 0.15 86 142 0.11 0.16 87 21 0.16 87 57 0.19 87 97 0.16 87 101 0.18 87 Ill 0.16 87 127 0.16 87 143 0.12 88 22 0.10 88 28 0.11 88 58 0.24 88 112 0.12 0.22 88 118 0.15 89 57 0.16 89 67 0.27 89 71 0.23 89 Ill 0.14 90 24 0.12 90 40 0.14 DEG 150 20 138 136 19 122 150 160 158 124 90 156 154 66 151 144 165 47 134 154 162 159 151 30 158 117 129 147 60 116 29 166 155 172 157 109 18 98 162 141 20 157 86 51 147 150 153 16 153 129 107 124 147 CHN IND %TW P2 TWD 19 P2 TWD 12 P2 TWD 18 P2 TWD 15 P2 TWD 13 P2 TWD 15 P2 TWD 13 P2 TWD 16 P2 TWD 10 P2 TWD 17 P2 TWD 11 P2 TWD 13 P2 TWD 19 P2 TWO 16 P2 TWD 17 P2 TWD 16 P2-TWD 14, P2 TWD 16 P2 TWD 18 P2 TWD 18 P2 TWD 16 P2 TWD 14 P2 TWD 19 P2 TWD 11 P2 TWD 15 P2 TWD 12 P2 TWD 14 P2 TWD 16 P2 TWD 14 P2 TWD 17 P2 TWD 12 P2 TWD 14 P2 TWD 9 P2 TWD 12 P2 TWD 13 P2 TWD 13 P2 TWD 12 P2 TWD 17 P2 TWD 16 P2 TWD 14 P2 TWD 9 P2 TWD 10 P2 TWD 11 P2 TWD 16 P2 TWD 10 P2 TWD 16 P2 TWD 16 P2 TWD 16 P2 TWD 17 P2 TWD 16 P2 TWD 11 P2 TWD 9 P2 TWD 18 LOCATION VS3

-0.99 VS4

+0.86 VS2

-1.29 VS2

-0.90 VS4

+0.79 VS4

-0.99 VS4

+0.90 06C

+0.80 08C

+0.98 08C

-1.04 VS3

-0.78 Vs3

-0.87 VS2

+0.93 VS4

+0.80 VS3

+0.79 VS2

+0.66 VS2

+0.90 05H

+0.88 VS3

-0.99 VS2

+0.69 VS2

-0.88 07H

+0.84 VS2

-0.81 VS2

+0.20 VS2

-1.09 VS3

+0.00 08H

+0.86 VS2

+0.90 VS2

-0.89 VS4

+0.82 VS4

-0.81 VS4

+0.76 VS3

+1.00 VS4

-0.98 VS2

-0.89 VS2

+0.90 VS4

-0.59 VS4

-0.81 VS3

-0.99 VS2

+0.45 VS4

+0.57 VS2

+1.02 VS3

+0.92 VS4

-0.57 VS4

-1.04 VS2

+0.74 08H

+0.96 VS2

+0.90 VS4

+0.88 VS2

+1.00 VS2

-0.85 VS2

-0.76 07H

+0.72 EXT TEN TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH.

TEH TEH TEH TEH TEN TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH EXT TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC-TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC CAL #

17 17 5

9 17 9

54 32 32 32 44 44 46 46 39 37 50 44 46 46 51 45 35 55 53 46 32 33 54 54 54 46 32 32 54 50 49 41 38 34 32 55 55 50 37 37 35 51 48 44 37 54 73 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 600UL 600UL 600UL 600UL 60OUL 600UL 600OUL 60OUL 600UL 600UL 60OUL 600UL 600UL 600UL 60OUL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 32 of 92 Areva NP 6/7/2006 9:07 AM Component: S/G A Customer Name: St. Lucie Unit 2 Page 6 of 9 Tubes with Bobbin 1-19% TWD Indications ROW LINE VOLTS 90 58 0.22 0.29 90 112 0.23 0.16 91 27 0.17 0.16 91 33 0.14 91 65 0.13 0.10 91 67 0.21 91 101 0.09 91 103 0.12 91 127 0.17 91 129 0.27 91 133 0.22 92 26 0.23 92 32 0.20 92 86 0.19 0.09 92 90 0.20 92 112 0.13 92 116 0.13 93 35 0.15 93 87 0.23 93 117 0.13 93 131 0.19 94 34 0.18 0.07 94 44 0.18 0.23 94 64 0.16 94 72 0.19 0.19 94 76 0.26 94 88 0.14 94 96 0.20 94 106 0.17 94 144 0.13 95 31 0.10 95 59 0.14 95 71 0.27 95 127 0.18 95 135 0.28 0.24 95 139 0.19 95 143 0.21 96 30 0.23 0.12 0.10 0.21 96 58 0.16 0.14 96 60 0.25 DEG 159 78 154 104 21 130 151 158 102 143 171 151 154 133 155 93 153 128 10 146 145 19 17 150 139 61 158 18 151 152 168 141 155 25 235 108 138 150 46 115 36 145 128 27 134 129 42 166 129 119 162 125 13 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWO TWD TWD TWD TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWO TWO TWD TWD TWD TWD TWD TWO TWD TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWO TWO TWD TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW 15 18 16 12 15 15 14 10 8

15 10 13 18 18 15 19 18 16 8

16 11 13 14 18 14 14 17 9

16 19 11 14 14 17 13 13 13 12 8

10 17 18 18 16 17 15 19 12 10 18 15 14 17 LOCATION VS3

-0.74 DHT

+0.00 VS2

-0.83 VS4

+0.74 VS4

-0.83 VS2

-0.57 VS4

+0.79 VS4

-0.79 VS4

-0.13 VS2

+0.63 08C

+0.98 VS2

-0.98 VS2

-0.74 VS2

-0.78 08C

+0.99 VS3

-0.85 VS2

-0.97 VS4

+0.74 VS2

-0.91 VS2

+0.83 VS3

-0.89 08C

+1.10 05H

-0.92 VS4

+0.92 VS3

+0.68 VS2

-0.98 VS2

-0.83 VS2

+0.36 DCT

+0.00 VS2

-0.85 VS4

-0.63 VS2

+0.97 VS4

+0.87 VS3

-0.40 VS3

-0.97 VS3

-0.40 VS2

+0.91 01C

+0.93 VS2

+0.86 VS3

-0.87 VS2

+0.83 VS2

-0.85 VS2

-0.94 VS2

+0.36 VS2

-1.01 VS2

-0.92 VS2

-0.85 VS3

-0.75 VS3

-0.09 VS4

+0.83 VS3

+0.87 VS3

-0.65 DHB

+3.75 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC CAL #

50 50 37 37 55 55 53 49 49 49 41 41 35 32 32 55 53.

47 47 47 37 38 52 47 38 32 53 53 52 52 48 44 44 44 46 48 39 33 54 50 44 35 32 32 33 32 55 55 55 55 51 51 49 LEG PROBE COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 6000L COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL COLD 600UL

St. Lucie Unit 2 L-2007-076 Docket Ns. 50-389 Attachment Page 33 of 92 Areva NP 6/7/2006 9:07 AM Customer Name: St. Lucie Unit 2 Component: S/G A Page 7 of 9 Tubes with Bobbin 1-19% TWD Indications ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 96 62 0.19 90 P2 TWD 14 VS3

-0.72 TEH TEC 49 COLD 600UL 96 108 0.08 166 P2 TWD 7 VS3

+0.88 TEH TEC 39 COLD 600UL 96 128 0.13 157 P2 TWD 13 VS2

-0.92 TEH TEC 33 COLD 600UL 0.09 31 P2 TWD 9 VS4

-0.80 TEH TEC 33 COLD 600UL 96 134 0.25 120 P2 TWD 17 VS2

+0.89 TEH TEC 32 COLD 600UL 96 138 0.28 137 P2 TWD 18 VS2

+0.91 TEH TEC 32 COLD 600UL 96 142 0.14 165 P2 TWD 14 VS4

-0.98 TEH TEC 33 COLD 600UL 97 31 0.19 165 P2 TWD 17 VS2

+1.03 TEH TEC 55 COLD 600UL 97 87 0.20 158 P2 TWD 16 V33

+0.79 TEH TEC 47 COLD 600UL 97 93 0.25 116 P2 TWD 19 VS4

+0.61 TEH TEC 46 COLD 600UL 0.18 55 P2 TWD 16 VS2

+0.19 TEH TEC 46 COLD 600UL 0.22 113 P2 TWD 18 VS2

-0.78 TEH TEC 46 COLD 600UL 97 127 0.16 78 P2 TWD 13 V$4

+0.68 TEH TEC 34 COLD 60OUL 0.22 129 P2 TWD 17 VS2

-0.72 TEH TEC 34 COLD 60OUL 97 137 0.18 135 P2 TWD 13 01C

+0.13 TEH TEC 32 COLD 600UL 97 141 0.20 128 P2 TWD 14 07C

-0.13 TEH TEC 32 COLD 600UL 98 26 0.231 147 P2 TWD 19 08H

-1.04 TEH TEC 55 COLD_

600UL_

98 28 0.15 136 P2 TWD 12 VS2

+0.92 TEH TEC 54 COLD 600UL 98 30 0.18 166 P2 TWD 14 VS3

+0.81 TEH TEC 54 COLD 60OUL 98 90 0.13 34 P2 TWD 12 DCT

-0.17 TEH TEC 47 COLD 600UL 99 27 0.13 144 P2 TWD 10 VSI

-0.48 TEH TEC 54 COLD 600UL 100 108 0.13 42 P2 TWD 10 DCT

+0.00 TEH TEC 39 COLD 600UL 101 27 0.21 69 P2 TWD 18 02H

-0.06 TEH TEC 55 COLD 600UL 101 109 0.25 30 P2 TWD 16 VS3

+0.76 TEH TEC 40 COLD 600UL 101 111 0,17 74 P2 TWD 13 08C

-0.94 TEH TEC 37 COLD 600UL 0.13 168 P2 TWD 10 08C

+0.94 TEH TEC 37 COLD 600UL 0.17 62 P2 TWD 13 07C

-1.03 TEH TEC 37 COLD 600UL 101 139 0.03 18 P2 TWD 3 VS2

-1.02 TEH TEC 32 COLD 600UL 102 140 0.18 32 P2 TWD 16 09H

-1.01 TEH TEC 33 COLD 600UL 103 39 0.16 163 P2 TWD 15 DCB

+0.00 TEH TEC 52 COLD 600UL 104 138 0.13 14 P2 TWD 13 08H

+0.84 TEH TEC 33 COLD 600UL 108 32 0.21 32 P2 TWD 18 VS2

+0.89 TEH TEC 52 COLD 600UL 111 87 0.13 147 P2 TWD 11 VS2

-1.01 TEH TEC 47 COLD 600UL 112 76 0.29 146 P2 TWD 18 VS2

-0.66 TEH TEC 44 COLD 600UL 113 131 0.20 80 P2 TWD 14 07H

-1.02 TEH TEC 32 COLD 600UL 115 101 0.07 20 P2 TWD 8 05H

+0.85 TEH TEC 41 COLD 600UL 116 42 0.23 105 P2 TWD 13 VS1

-0.99 TEH TEC 52 COLD 600UL 0.32 58 P2 TWD 17 VS1

+0.99 TEH TEC 52 COLD 600UL 116 78 0.11 114 P2 TWD 11 VSI

-0.80 TEH TEC 45 COLD 600UL 117 43 0.13 154 P2 TWD 12 VS4

+0.93 TEH TEC 52 COLD 600UL 117 55 0.15 25 P2 TWD 11 VS1

+0.80 TEH TEC 50 COLD 600UL 119 105 0.17 167 P2 TWD 13 03H

+0.89 TEH TEC 39 COLD 600UL 121 49 0.23 46 P2 TWD 15 DCT

-0.06 TEH TEC 50 COLD 600UL 122 44 0.12 110 P2 TWD 12 DCB

+0.00 TEH TEC 52 COLD 600UL 123 47 0.17 121 P2 TWD 12 VS2

+0.63 TEH TEC 50 COLD 600UL 123 49 0.12 157 P2 TWD 13 VS1

+0.84 TEH TEC 51 COLD 600UL 123 55 0.19 147 P2 TWD 17 VS1

-0.99 TEH TEC 51 COLD 600UL 123 57 0.14 152 P2 TWD 14 VSI

+0.66 TEH TEC 51 COLD 600UL 123 113 0.11 57 P2 TWD 9 VS5

+0.89 TEH TEC 37 COLD 600UL 123 119 0.14 114 P2 TWD 14 VS4

-0.96 TEH TEC 36 COLD 600UL 124 50 0.22 52 P2 TWD 19 DHT

+0.00 TEH TEC 51 COLD 600UL 0.08 11 P2 TWD 9 VS2

+0.60 TEH TEC 51 COLD 600UL 124 54 0.16 34 P2 TWD 15 DCT

-0.25 TEH TEC 51 COLD 600UL

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 34 of 92 Areva NP 6/7/2006 9:07 AM Component: S/G A Customer Name:

St. Lucie Unit 2 Page 8 of 9 Tubes with Bobbin 1-19% TWO Indications ROW LINE VOLTS 124 66 0.16 125 47 0.18 125 49 0.15 125 51 0.17 125 57 0.09 125 59 0.15 0.25 125 79 0.13 125 99 0.12 125 101 0.07 125 105 0.11 125 107 0.28 125 115 0.17 125 121 0.14 126 50 0.20 0.17 0.11-126 60 0.21 126 72 0.24 126 74 0.12 126 86 0.11 126 96 0.17 0.20 126 104 0.17 127 51 0.17 0.14 127 57 0.18 127 59 0.23 0.09 127 107 0.21 127 115 0.15 128 60 0.07 0.25 128 116 0.21 129 55 0.25 129 63 0.23 130 58 0.30 130 64 0.25 131 79 0.18 132 64 0.13 0.13 132 68 0.19 132 102 0.20 132 110 0.12 133 61 0.30 0.32 0.23 133 67 0.20 133 77 0.13 133 109 0.16 134 62 0.15 0.15 0.11 DEG 147 42 137 91 131 23 14 77 15 44 143 110 167 163 74 143 18 54 35 134 150 84 132 142 131 46 80 71 45 46 144 172 137 116 129 24 88 147 136 84 170 141 126 157 138 67 12 39 166 95 150 82 22 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWO 11 TWO 17 TWD 11 TWD 16 TWD 7 TWO 11 TWD 16 TWD 13 TWO 9 TWD 8 TWO 12 TWO 18 TWD 14 TWO 16 TWD 14 TWD 12 TWO, 9 TWO 14 TWD 16 TWO 12 TWD 11 TWO 12 TWO 13 TWO 17 TWO 12 TWD 10 TWD 16 TWD 19 TWD 10 TWD 16 TWO 12 TWO 8 TWO 14 TWD 16 TWD 16 TWO 16 TWO 18 TWO 17 TWO 14 TWD 11 TWD 10 TWO 14 TWO 15 TWO 16 TWD 15 TWO 15 TWD 15 TWO 15 TWO 17 TWO 9 TWO 18 TWO 18 TWO 15 LOCATION VSI

+0.81 OCT

+0.00 VS1

+0.89 DHT

+0.00 OCT

+0.00 VS1

+0.71 OCT

+0.00 VS1

-0.71 09C

-0.74 VS5

-0.66 08C

+0.62 VS1

+0.84 VS1

+0.94 07H

+0.86 05H

-0.30 03H

+0.88 07H1

-0.28 08H

+0.73 09H

+0.13 VS2

+0.81 09H

-0.97 07C

+0.00 08H

-0.94 VS2

+0.90 04H

-0.77 09H

+0.88 VS1

+0.63 VS1

-0.24 DCT

+0.00 OCT

+0.00 VS1

-0.96 VS5

-0.65 DHB

+0.11 VS2

+0.94 DCB

+0.00 VS1

+0.71 DCB

+0.19 VS1

+0.62 VS4

-0.86 07H

+0.61 DHB

+0.00 VS2

-1.00 OCT

+0.00 VS5

-0.99 DHB

+0.00 DHT

+0.00 OCT

-0.17 VS1

+0.68 VS5

+0.77 DHB

+0.00 07H

+0.88 DHT

-0.04 OCT

+0.11 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH -TEC.

TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC CAL #

48 51 50 51 50 50 50 45 49 41 41 39 58 35 50 50 50-50 44 45 46 48 48 41 50 50 51 51 51 58 37 51 51 58 50 49 50 49 56 56 56 56 56 57 57 57 57 56 57 57 57 57 57 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD.

COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600OUL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600OL 600OUL 60OUL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 6 0 0L 600UL 600UL 600UL 600UL 600OUL 600UL 600OL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 35 of 92 Areva NP 6/7/2006 9:07 AM Component: S/G A Customer Name: St. Lucie Unit 2 Page 9 of 9 Tubes with Bobbin 1-19% TWD Indications ROW LINE VOLTS 0.15 134 72 0.12 134 76 0.10 134 100 0.10 134 104 0.16 135 63 0.48 135 71 0.24 135 73 0.25 0.17 0.26 135 97 0.15 135 99 0.14 0.12 136 70 0.10 136 76 0.27 136 98 0.11 136 102-0.16...

137 69 0.12 137 97 0.11 DEG CHN 136 P2 132 P2 154 P2 154 P2 21 P2 120 P2 49 P2 122 P2 47 P2 40 P2 26 P2 81 P2 102 P2 166 P2 109 P2 171 P2 17 P2 152 P2 142 P2 IND %TW LOCATION TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWO TWD TWD TWD TWD TWD 18 9

9 8

13 10 17 17 13 18 12 11 10 13 18 9

19.

15 14 VS3 VS5 VS5 VS4 05H DHT VS1 VS2 VS5 VS1 VS5 VS5 DCB VS5 DCT VS1 VSI1 07H DCB

+0.95

+1.05

-1.01

-0.76

+0.70

+0.00

-0.91

+0.67

+0.88

-0.76

+0.17

-0.81

+0.32

-0.94

-0.09

-0.83

-0.95

+0.70

+0.36 EXT TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH EXT TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC-TEC TEC CAL #

57 57 56 56 56 57 56 56 56 56 56 56 56 57 56 56

-57.

57 57 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD-COLD COLD PROBE 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 60OUL 600UL 600UL.

600UL 600UL Total Tubes

375 Total Records:

443

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 36 of 92 Areva NP 6/7/2006 9:12 AM Component: S/G B Customer Name: St. Lucie Unit 2 Page 1 of 20 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS 1

25 0.21 1

109 0.19 0.24 0.17 1

113 0.17 1

143 0.24 1

147 0.31

1.

151 0.67 1

155 0.23 0.20 2

54 0.31 2

114 0.16 0.30 0.34 0.22 2

144 0.39 2

154 0.13 2

158 0.31 2

160 0.25 0.20 2

164 0.25 3

19 0.14 3

39 0.15 3

53 0.19 0.15 0.18 0.17 3

109 0.80 0.23 3

111 0.19 0.20 3

135 0.29 0.42 3

137 0.35 3

145 0.19 3

153 0.24 0.15 4

20 0.12 0.21 0.28 4

30 0.23 0.33 4

34 0.20 4

44 0.29 4

58 0.33 0.26 4

60 0.21 4

110 0.33 0.45 4

114 0.29 0.24 0.19 DEG CHN 91 P6 113 P6 116 P6 109 P6 102 P6 91 P6 98 P6 87 P6 88 P6 78 P6 93 P6 119 P6 96 P6 92 P6 96 P6 101 P6 72 P6 85 P6 103 P6 68 P6 106 P6 94 P6 64 P6 102 P6 276 P6 54 P6 102 P6 104 P6 100 P6 81 P6 93 P6 106 P6 84 P6 85 P6 66 P6 79 P6 70 P6 69 P6 64 P6 110 P6 94 P6 93 P6 91 P6 290 P6 103 P6 100 P6 92 P6 115 P6 109 P6 90 P6 67 P6 71 P6 IND SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI

_SAI SAI MAI SAI SAI SAI SAI MAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI MAI SAI SAI SAI SAI MAI SAI SAI SAI SAI SAI SAI SAI SAI

%TW LOCATION 06H

+0.46 07H

+0.90 DCT

-0.17 07C

+0.11 04H

+0.80 03H

-0.24 03H

-0.19 06H

+0.49 05H

-0.46 05H

+0.75 03H

+0.65 01H

+0.90 05H

+0.81 06H

+0.28 04H

+0.72 03H

-0.54 04H

-0.38 03H

+0.71 03H

-0.11 03H

+0.60 03H

-0.26 05H

-0.23 06H

+0.78 06H

-0.58 06H

+0.09 06H

+0.20 06H

+0.76 06H

+0.00 06H

+0.96 01H

-0.75 01H

+0.79 03H

+0.94 06H

+0.23 06H

-0.37 03H

+0.77 03H

-0.23 03H

+0.85 02H

-0.23 02H

+0.83 03H

+0.61 DHB

+1.69 03H

+0.60 05H

+0.81 07H

+0.66 05H

+0.73 05H

+0.03 07H

+0.71 06H

+0.01 07H

+0.71 06H

-0.24 07H

-0.44 07H

+0.83 EXT 06H 07H 07H 07H 04H 03H 03H 06H 05H 05H 03H 01H 05H 06H 04H 03H 04H 03H 03H 03H 03H 05H 06H 06H 06H 06H 06H 06H 06H 01H 01H 03H 06H 06H 03H 03H 03H 02H 02H 03H 07H 03H 05H 07H 05H 05H 07H 06H 07H 06H 07H 07H EXT CAL # LEG 06H 117 HOT 07C 140 HOT 07C 140 HOT 07C 140 HOT 04H 121 HOT 03H 121 HOT 03H 121 HOT 06H 154 HOT 05H 154 HOT 05H 154 HOT 03H 117 HOT 01H 154 HOT 05H 154 HOT 06H 154

-HOT 04H 159 HOT 03H 15A HOT.

04H 154 HOT 03H 121 HOT 03H 139 HOT 03H 139 HOT 03H 121 HOT 05H 117 HOT 06H 117 HOT 06H 117 HOT 06H 117 HOT 06H 117 HOT 06H 117 HOT 06H 121 HOT 06H 121 HOT 01H 121 HOT 01H 121 HOT 03H 121 HOT 06H 121 HOT 06H 121 HOT 03H 121 HOT 03H 154 HOT 03H 154 HOT 02H 117 HOT 02H 117 HOT 03H 117 HOT DCB 144 HOT 03H 153 HOT 05H 117 HOT DHT 130 HOT 05H 117 HOT 05H 117 HOT DHT 130 HOT 06H 139 HOT 07H 121 HOT 06H 154 HOT DHT 154 HOT DHT 154 HOT PROBE 5803P 5601P 5601P 5601P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5402P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 37 of 92 Areva NP 6/7/2006 9:12 AM Component: S/G B Customer Name: St. Lucie Unit 2 Page 2 of 20 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS 4

130 0.23 0.30 4

142 0.12 4

146 0.30 4

164 0.57 0.14 5

43 0.23 0.22 5

111 0.27 5

157 0.16 6

22 0.29 7

25 0.17 0.17 0.34 0.28 0.16 0.42 8

14 0.28 8

20 0.15 8

26 0.18 8

148 0.20 8

154 0.27 8

160 0.19 9

7 0.26 9

143 0.27 9

155 0.20 0.18 10 48 0.15 10 54 0.20 0.23 0.38 10 108 0.53 10 158 0.18 11 27 0.26 11 29 0.17 11 39 0.17 11 43 0.35 11 53 0.24 0.29 0.29 11 57 0.19 11 61 0.15 0.24 0.30 0.16 11 119 0.43 0.18 11 121 0.39 0.19 0.18 11 135 0.17 11 147 0.40 DEG CHN IND 76 P6 MAI 118 P6 SAI 76 P6 SAI 105 P6 SAI 93 P6 SAI 121 P4 SAI 263 P6 SAI 271 P6 SAI 100 P6 SAI 109 P6 SAI 103 P6 SAI 88 P6 SAI 93 P6 SAI 81 P6 SAI 88 P6 SAI 55 P6-SAL 88 P6 SAI 104 P6 SAI 85 P6 SAI 93 P6 SAI 87 P6 SAI 83 P6 SAI 61 P6 MAI 82 P6 SAI 71 P6 SAI 99 P6 SAI 79 P6 SAI 255 P6 SAI 82 P6 SAI 83 P6 SAI 269 P6 MAI 104 P6 MAI 73 P6 SAI 71 P6 SAI 49 P6 SAI 113 P6 SAI 115 P6 SAI 113 P6 SAI 119 P6 MAI 92 P6 SAI 92 P6 SAI 86 P6 SAI 110 P6 SAI 98 P6 SAI 74 P6 SAI Il1 P6 SAI 90 P6 SAI 96 P6 SAI 107 P6 SAI 60 P6 SAI 88 P6 SAI 96 P6 SAI

%TW LOCATION 07H

-0.56 07H

+0.57 02H

+0.86 03H

-0.33 03H

+0.13 03H

+0.89 05H

-0.46 05H

+0.80 01H

-0.58 03H

+0.49 02H

-0.49 06C

-0.74 06C

+0.89 05C

+0.83 03H

+0.84 05H

+0.88 06H

-0.26 01H

+0.25 01H

-0.74 02H

+0.52 03H

+0.74 04H

+0.45 02H

-0.36 03H

+0.46 05H

-0.18 03H

-0.39 03H

+0.36 03H

+0.52 01H

+0.29 06H

+0.36 07H

+0.57 06H

-0.41 02H

+0.69 01H

+0.39 01H

-0.28 01H

-0.48 06H

+0.76 05H

-0.40 05H

+0.86 06H

+0.05 03H

+0.63 05H

-0.38 05H

+0.85 06H

-0.70 06H

+0.31 01H

+0.47 02H

+0.17 04H

+0.72 06H

+0.82 06H

-0.07 02H

+0.89 02H

+0.35 EXT EXT CAL # LEG PROBE 07H 07H 121 HOT 5803P 07H 07H 121 HOT 5803P 02H 02H 121 HOT 5803P 03H 03H 121 HOT 5803P 03H 03H 121 HOT 5803P 03H 03H 121 HOT 5803P 05H 05H 130 HOT 5803P 05H 05H 130 HOT 5803P 01H 01H 94 HOT 5803P 03H 03H 94 HOT 5803P 02H 02H 127 HOT 5803P 06C 06C 87 COLD 5803P 06C 06C 87 COLD 5803P 05C 05C 87 COLD 5803P 03H 03H 129 HOT 5803P 05H 05H 129 HOT 5803P 06H 06H 129 HOT 5803P 01H 01H 117 HOT 5803P 01H 01H 127 HOT 5803P 02H 02H 129 HOT 5803P 03H 03H 94 HOT 5803P 04H 04H 139 HOT 5803P 02H 02H 94 HOT 5803P 03H 03H 117 HOT 5803P 05H 05H 94 HOT 5803P 03H 03H 94 HOT 5803P 03H 03H 94 HOT 5803P 03H 03H 130 HOT 5803P 01H 01H 142 HOT 5803P 06H 06H 142 HOT 5803P 07H 07H 130 HOT 5803P 06H 06H 94 HOT 5803P 02H 02H 94 HOT 5803P 01H 01H 129 HOT 5803P 01H 01H 129 HOT 5803P 01H 01H 64 HOT 5803P 06H 06H 64 HOT 5803P 05H 05H 64 HOT 5803P 05H 05H 64 HOT 5803P 06H 06H 64 HOT 5803P 03H 03H 64 HOT 5803P 05H 054 115 HOT 5803P 05H 05H 115 HOT 5803?

06H 06H 64 HOT 5803P 06H 06H 64 HOT 5803P 01H 01H 105 HOT 5803P 02H 02H 105 HOT 5803P 04H 04H 105 HOT 5803?

06H 06H 105 HOT 5803P 06H 06H 105 HOT 5803P 02H 02H 94 HOT 5803P 02H 02H 100 HOT 5803P

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 38 of 92 Areva NP 6/7/2006 9:12 AM Component: S/G B Customer Name: St. Lucie Unit 2 Page 3 of 20 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 0.33 0.21 0.46 0.37 0.26 11 165 0.69 12 14 0.51 0.72 12 18 0.42 0.29 0.22 12 24 0.12 12 26 0.19 0.26 12 30 0.18 0.15 0.18 12 48 0.29 12 54 0.37 0.44 12 56 0.27 12 106 0.24 12 114 0.34 0.40 0.17 12 120 0.28 0.43 0.23 0.30 12 124 0.13 12 128 0.38 0.16 0.38 0.44 0.30 0.30 12 132 0.26 0.30 12 136 0.35 0.13 0.26 0.29 12 148 0.20 0.32 0.32 13 31 0.13 13 37 0.35 0.22 0.30 13 109 0.14 13 111 0.24 13 115 0.28 116 P6 102 P6 108 P6 98 P6 93 P6 97 P6 90 P6 96 P6 105 P6 78 P6 79 P6 118 P6 94 P6 72 P6 62 P6 61 P6 100 P6 95 P6 110 P6 91 P6 93 P6 103 P6 105 P6 102 P6 88 P6 92 P6 106 P6 81 P6 115 P6 95 P6 103 P6 77 P6 110 P4 103 P4 65 P6 74 P6 73 P6 66 P6 79 P6 51 P6 99 P6 75 P6 86 P6 85 P6 97 P6 78 P6 109 P6 60 P6 93 P6 92 P6 87 P6 85 P6 SAI SAI MAI SAI SAI MAI MAI SAI SAI SAI SAI SAI MAI MAI SAI SAI SAI SAI SAI SAI SAI SAI SAI MAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI 03H 04H 04H 05H 05H 03H 03H 05H 03H 02H 02H 01H 03H 05H 01H 01H 07H 01H 05H 05H 05H 02H 06H 07H 07H 01H 03H 03H 05H 01H 05H 05H 03H 03H 07H 07H 07H 07H 02H 02H 07H 07H 03H 04H 05H 01H 03H 03H 06H 01H 01H 05H

+0.94

-0.89

+0.69

-0.62

+0.77

-0.36

+0.78

-0.44

+0.39

-0.37

+0.64

-0.49

+0.74

+0.85

+0.77

-0.42.

+0.86

+0.87

-0.52

-0.14

+0.43

+0.87

-0.39

-0.69

+0.21

-0.64

+0.92

+0.02

+0.67

+0.67

+0.83

-0.19

-0.06

+0.37

-0.58

+0.60

-0.21

+0.72

-0.49

+0.60

-0.46

+0.47

+0.77

-0.03

-0.03

-0.20

-0.

67

+0.93

+0.33

-0.28

+0.16

+0.51 03H 03H 04H 04H 04H 04H 05H 05H 05H 05H 03H 03H 03H 03H 05H 05H 03H 03H 02H 02H 02H 02H 01H 01H 03H 03H 05H 05H 01H 01H 01H 01H 07H 07H 01H 01H 05H 05H 05H 05H 05H 05H 02H 02H 06H 06H 07H 07H 07H 07H 01H 01H 03H 03H 03H 03H 05H 05H 01H 01H 05H 05H 05H 05H 03H 03H 03H 03H 07H 07H 07H 07H 07H 07H 07H 07P 02H 02H 02H 02H 07H 07H 07H 07H 03H 03H 04H 04H 05H 05H 01H 01H 03H 03H 03H 03H 03H 06H 01H 01H 01H 01H 05H 05H 100 100 100 100 100 99 127 127 127 153 153 129 129 129 142 142 130 64 64 64 64 105 105 105 105 105 105 105 105 108 122 122 108 108 108 108 94 94 94 94 94 94 100 100 100 130 130 130 130 105 122 105 HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT.

HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P

St. Lucie Unit 2 L-2007-076 Docket Ns. 50-389 Attachment Page 39 of 92 Areva NP 6/7/2006 9:12 AM Customer Name: St. Lucie Unit 2 Component: S/G B Page 4 of 20 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 0.17 105 P6 SAI 06H

+0.95 06H 06H 105 HOT 5803P 13 117 0.22 115 P6 SAI 03H

+0.85 03H 03H 105 HOT 5803P 13 121 0.18 76 P6 SAI 02H

+0.12 02H 02H 122 HOT 5803P 0.25 93 P6 MAI 05H

+0.29 05H 05H 122 HOT 5803P 0.21 73 P6 SAI 07H

-0.21 07H 07H 108 HOT 5803P 13 123 0.26 94 P6 SAI 01H

+0.62 01H 01H 108 HOT 5803P 13 129 0.28 66 P6 SAI 03H

+0.36 03H 03H 122 HOT 5803P 0.30 107 P6 SAI 03H

+0.86 03H 03H 122 HOT

5803P, 0.28 86 P6 MAI 04H

+0.88 04H 04H 122 HOT 5803P 0.21 100 P6 SAI 05H

-0.24 05H 05H 108 HOT 5803P 0.21 78 P6 SAI 05H

+0.89 05H 05H 108 HOT 5803P 13 149 0.15 92 P6 SAI 03H

+1.00 03H 03H 100 HOT 5803P 0.39 110 P6 SAI 05H

-0.25 05H 05H 100 HOT 5803P 0.24 88 P6 SAI 05H

+0.88 05H 05H 100 HOT 5803P 13 153 0.24 93 P6 SAI 02H

-0.71 02H 02H 100 HOT 5803P 0.38 103 P6 SAI 02H

+0.19-02H 02H 100 HOT 5803P.

0.18 66 P6 SAI 02H

+0.73 02H 02H 100 HOT 5803P 0.13 110 P6 SAI 03H

+0.81 03H 03H 100 HOT 5803P 14 144 0.11 62 P6 SAI 02H

+0.89 02H 02H 99 HOT 5803P 14 152 0.16 36 P6 SAI 01H

+0.76 01H 01H 100 HOT 5803P 15 19 0.42 88 P6 SAI 03H

-0.46 03H 03H 127 HOT 5803P 15 33 0.35 79 P6 SAI 01H

-0.40 01H 01H 130 HOT 5803P 0.23 65 P6 SAI 01H

+0.14 01H 01H 130 HOT 5803P 15 43 0.20 109 P6 SAI 01H

-0.62 01H 01H 64 HOT 5803P 0.30 94 P6 SAI 01H

+0.49 01H 01H 64 HOT 5803P 15 111 0.29 105 P6 SAI 07H

+0.14 07H DCB 125 HOT 5602P 15 129 0.28 84 P6 SAI 05H

-0.12 05H 05H 101 HOT 5803P 15 131 0.13 76 P6 SAI 03H

-0.42 03H 03H 94 HOT 5803P 15 147 0.20 70 P6 SAI 02H

+0.79 02H 02H 100 HOT 5803P 0.19 75 P6 SAI 04H

+0.21 04H 04H 100 HOT 5803P 16 18 0.36 90 P6 SAI 02H

-0.26 02H 02H 127 HOT 5803P 16 26 0.25 79 P6 SAI 01H

-0.57 01H 01H 129 HOT 5803P 16 44 0.41 99 P6 SAI 01H

+0.81 01H 01H 64 HOT 5803P 0.27 115 P6 SAI 06H

+0.75 06H 06H 64 HOT 5803P 16 46 0.41 81 P6 SAI 06H

+0.49 06H 06H 64 HOT 5803P 16 110 0.40 101 P6 SAI 01H

+0.66 01H 01H 105 HOT 5803P 16 116 0.41 101 P6 SAI 05H

+0.69 05H 05H 105 HOT 5803P 16 118 0.31 80 P6 SAI 06H

-0.79 06H 06H 105 HOT 5803P 16 126 0.21 87 P6 SAI 03H

+0.89 03H 03H 108 HOT 5803P 0.14 71 P6 MAI 07H

-0.51 07H 07H 108 HOT 5803P 16 150 0.20 85 P6 SAI 04H

+0.79 04H 04H 100 HOT 5803P 17 27 0.17 87 P6 MAI 03H

+0.93 03H 03H 129 HOT 5803P 0.18 99 P6 SAI 05H

+0.57 05H 05H 129 HOT 5803P 0.16 82 P6 SAI 05H

+0.24 05H 05H 129 HOT 5803P 17 45 0.18 80 P6 MAI 06H

+0.66 06H 06H 115 HOT 5803P 17 109 0.36 95 P6 SAI 07H

-0.46 07H 07H 105 HOT 5803P 0.15 72 P6 SAI 02H

+0.42 02H 02H 105 HOT 5803P 17 127 0.39 86 P6 SAI 01H

+0.70 01H 01H 108 HOT 5803P 17 143 0.20 93 P6 SAI 03H

+0.08 03H 03H 99 HOT 5803P 0.13 112 P6 SAI 03H

+0.97 03H 03H 99 HOT 5803P 17 149 0.19 94 P6 SAI 03H

+0.79 03H 03H 100 HOT 5803P 17 153 0.26 96 P6 SAI 02H

-0.46 02H 02H 100 HOT 5803P

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 40 of 92 Areva NP 6/7/2006 9:12 AM Component: S/G B Customer Name: St. Lucie Unit 2 Page 5 of 20 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG 17 163 0.24 18 20 0.25 18 58 0.17 18 60 0.16 18 114 0.15 18 118 0.22 18 142 0.31 18 146 0.28 0.16 18 148 0.19 18 154 0.13 0.15 19 13 0.19 19 59 0.27 19 115 0.34 19 119 0.22 19 123 0.19 19 137 0.12 19 145 0.22 19 149 0.11 0.14 0.18 0.15 19 151 0.14 0.18 0.16 0.17 19 157 0.21 20 24 0.18 0.21 20 30 0.23 20 116 0.28 0.33 20 120 0.20 20 132 0.13 0.14 20 148 0.19 20 164 0.48 0.37 0.61 0.23 21 45 0.15 21 47 0.35 21 113 0.23 0.33 0.18 21 117 0.20 21 119 0.14 0.16 0.15 0.37 21 123 0.15 114 P6 SAI 74 P6 SAI 84 P6 SAI 99 P6 SAI 99 P6 SAI 108 P6 SAI 97 P6 SAI 106 P6 SAI 90 P6 SAI 72 P6 SAI 77 P6 SAI 75 P6 SAI 71 P6 SAI 97 P6 SAI 88 P6 MAI 100 P6 SAI 66 P6 MAI 73 P6 SAI 73 P6 SAI 78 P6 SAI 59 P6 MAI 73 P6 SAI 77 P6 SAI 100 P6 SAI 72 P6 SAI 63 P6 SAI 88 P6 SAI 53 P6 SAI 68 P6 SAI 79 P6 SAI 80 P6 MAI 109 P6 SAI 92 P6 SAI 90 P6 SAI 106 P6 SAI 65 P6 SAI 96 P6 MAI 89 P6 SAI 96 P6 SAI 95 P6 SAI 97 P6 SAI 83 P6 SAI 91 P6 SAI 81 P6 SAI 115 P6 SAI 96 P6 SAI 96 P6 SAI 47 P6 SAI 88 P6 SAI 76 P6 SAI 98 P6 SAI 68 P6 SAI 02H 02H 01H 02H 01H 01H 03H 02H 02H 04H 02H 02H 05H 01H 05H 01H 01H 02H 04H 02H 02H 03H 05H 02H 02H 03H 03H 03H 01H 04H 03H 04H 05H 03H 01H 04H 03H 02H 03H 04H 04H 06H 01H 01H 05H 07H 06H 01H 01H 03H 05H 01H

+0.69

-0.45

+0.39

+0.29

+0.64

+0.67

-0.02

-0.43

+0.65

+0.90

-0.50

+0.33

+0.63

+0.60

+0.52

-0.23

+0.85

+0.78

+0.91

+0.00

+0.93

+0.90

+0.02

+0.04

+0.50

-0.18

+0.85

-0.49

+0.50

+0.71

+0.80

+0.14

+0.57

+0.81

+0.55

+0.79

+0.91

-0.68

+0.67

-0.60

+0.68

+0.87

-0.49

+0.81

-0.53

-0.75

-0.08

-0.69

+0.58

+0.69

+0.43

+0.90 02H 02H 99 02H 02H 127 01H 01H 64 02H 02H 64 01H 01H 122 01H 01H 105 03H 03H 99 02H 02H 100 02H 02H 100 04H 04H 100 02H 02H 100 02H 02H 100 05H 05H 127 01H 01H 64 05H 05H 105 01H 01H 108 01H 01H 108 02H 02H 95 04H 04H 100 02H 02H 100 02H 02H 100 03H 03H 100 05H 05H 100 02H 02H 100 02H 02H 100 03H 03H 100 03H 03H 100 03H 03H 100 01H 01H 142 04H 04H 129 03H 03H 130 04H 04H 122 05H 05H 105 03H 03H 108 01H 01H 94 04H 04H 94 03H 03H 100 02H 02H 99 03H 03H 99 04H 04H 99 04H 04H 99 06H 06H 64 01H 01H 64 01H 01H 105 05H 05H 105 07H 07H 105 06H 06H 105 01H 01H 139 01H 01H 139 03H 03H 122 05H 05H 108 01H 01H 108 HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 41 of 92 Areva NP 6/7/2006 9:12 AM Component: S/G B Customer Name: St. Lucie Unit 2 Page 6 of 20 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS DEG CHN IND %TW LOCATION 21 137 0.17 21 153 0.11 21 159 0.19 22 24 0.29 0.14 22 52 0.18 0.24 0.52 22 108 0.30 22 146 0.21 0.13 0.26 0.51 22 156 0.16 0.33 23 109 0.34.

23 119 0.44 0.25 23 121 0.35 23 137 0.62 23 143 0.25 0.19 23 145 0.17 23 149 0.15 24 38 0.23 24 48 0.69 0.12 0.21 0.23 24 56 0.30 24 116 0.23 24 130 0.20 24 132 0.12 0.17 0.19 24 134 0.24 24 136 0.16 25 15 0.35 25 21 0.11 0.13 25 137 0.13 25 139 0.20 25 143 0.20 25 147 0.30 25 161 0.18 26 30 0.49 0.18 26 56 0.23 26 62 0.31 26 110 0.32 0.25 26 112 0.18 78 P6 95 P6 65 P6 115 P6 109 P6 80 P6 100 P6 91 P6 76 P6 68 P6 76 P6 75 P6 93 P6 67 P6 96 P6 109 P6 86 P6 106 P6 113 P6 99 P6 89 P6 82 P6 58 P6 100 P6 121 P6 102 P6 43 P6 74 P6 97 P6 104 P6 103 P6 99 P6 66 P6 94 P6 71 P6 94 P6 79 P6 91 P6 40 P6 72 P6 67 P6 77 P6 75 P6 84 P6 252 P6 110 P6 108 P6 43 P6 117 P6 11 P6 72 P6 77 P6 SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI MAI SAI SAI MAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI MAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI 02H 03H 02H 03H 03H 05H 05H 05H 01H 03H 03H 05H 05H 02H 02H 04H.

01H 01H 07H 05H 05H 05H 04H 03H 03H 01H 04H 04H 01H 01H 01H 05H 02H 03H 03H 01H 01H 05H 03H 03H 02H 03H 03H 02H 03H 05H 05H 07H 03H 02H 03H 07H

+0.89

+0.83

+0.44

-0.71

+0.75

-0.85

+0.11

+0.79

+0.93

+0.02

+0.64

-0.57

+0.81

-0.33

+0.90

+0.65-

+0.35

+0.81

-0.41

+0.48

+0.64

-0.06

+0.78

+0.95

+0.96

+0.03

-0.47

+0.75

+0.86

+0.75

+0.80

+0.58

+0.38

+0.22

+0.73

-0.50

+0.16

+0.52

-0.41

+0.79

+0.74

+0.22

+0.23

+0.84

+0.71

-0.76

+0.75

-0.84

+0.47

+0.57

+0.73

-0.65 EXT EXT CAL 4 LEG 02H 02H 95 HOT 03H 03H 100 HOT 02H 02H 100 HOT 03H 03H 129 HOT 03H 03H 129 HOT 05H 05H 64 HOT 05H 05H 64 HOT 05H 05H 64 HOT 01H 01H 105 HOT 03H 03H 100 HOT 03H 03H 100 HOT 05H 05H 100 HOT 05H 05H 100 HOT 02H 02H 100 HOT 02H 02H 100 HOT 04H 04H 105' HOT 01H 01H 108 HOT 01H 01H 108 HOT 07H 07H 108 HOT 05H 05H 95 HOT 05H 05H 99 HOT 05H 05H 99 HOT 04H 04H 100 HOT 03H 03H 100 HOT 03H 03H 64 HOT 01H 01H 64 HOT 04H 04H 64 HOT 04H 04H 64 HOT 01H 01H 64 HOT 01H 01H 64 HOT 01H 01H 105 HOT 05H 05H 94 HOT 02H 02H 94 HOT 03H 03H 94 HOT 03H 03H 94 HOT 01H 01H 121 HOT 01H 01H 95 HOT 05H 05H 127 HOT 03H 03H 127 HOT 03H 03H 127 HOT 02H 02H 95 HOT 03H 03H 95 HOT 03H 03H 99 HOT 02H 02H 100 HOT 03H 03H 95 HOT 05H 05H 130 HOT 05H 05H 130 HOT 07H 07H 64 HOT 03H 03H 68 HOT 02H 02H 105 HOT 03H 03H 105 HOT 07H 07H 104 HOT PROBE 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P2 5803P 5803P 5803P 5803P 5803P 58032 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 58032 5803P

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 42 of 92 Areva NP 6/7/2006 9:12 AM Component: S/G B Customer Name: St. Lucie Unit 2 Page 7 of 20 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG 26 132 0.35 0.48 27 27 0.23 27 29 0.29 27 45 0.17 0.16 27 57 0.23 27 109 0.33 0.37 0.19 27 115 0.15 27 117 0.18 0.21 27 119 0.18 27 137 0.18 0.30 27 159 0.53 0.21 28 14 0.11 28 24 0.46 28 112 0.20 28 120 0.27 28 144 0.26 29 9

0.33 29 15 0.31 29 21 0.19 0.25 29 103 0.19 29 141 0.16 29 145 0.19 29 147 0.18 0.24 30 16 0.13 30 40 0.21 0.30 0.13 30 110 0.18 30 146 0.19 0.35 0.24 0.23 31 27 0.16 31 41 0.39 31 45 0.24 31 63 0.26 0.33 0.10 0.20 0.16 31 145 0.46 0.29 0.23 85 P6 105 P6 90 P6 92 P6 89 P6 63 P6 88 P6 103 P6 101 P6 88 P6 57 P6 155 P6 83 P6 70 P6 45 P6 79 P6 99 P6 70 P6 92 P6 98 P6 86 P6 75 P6 86 P6 94 P6 102 P6 77 P6 90 P6 131 P6 76 P6 56 P6 98 P6 75 P6 64 P6 79 P6 103 P6 93 P6 101 P6 84 P6 93 P6 102 P6 92 P6 98 P6 106 P6 109 P6 101 P6 83 P6 46 P6 116 P6 80 P6 98 P6 70 P6 70 P6 SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAL SAI SAI SAI SAI SAI MAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI MAI SAI SAI SAI SAI MAI SAI SAI SAI SAI SAI SAI SAI 05H 05H 03H 03H 01H 01H 01H 06H 07H 07H 01H 03H 03H 07H 02H 02H 02H 02H 01H 07H 07H 06H 05H 06C 05H 03H 03H 05H 01H 01H 03H 03H 05H 05H 05H 06H 06H 02H 03H 05H 07H 01H 06H 01H 01H 02H 02H 03H 03H 02H 05H 05H

-0.27

+0.45

-0.72

-0.25

-0.53

+0.32

-0.71

+0.85

-0.56

+0.28

-0.47

-0.55

+0.64

+0.45

-0.30

+0.59

-0.26

+0.99

+0.43

-0.26

+0.52

+0.15

+0.82

+0.81

+0.78

+0.82

-0.54

+0.33

+0.82

+0.89

-0.91

+0.70

+0.78

-0.16

+0.99

+0.25

+0.93

-0.17

+1.02

+0.90

-0.67

+0.44

+0.23

-0.49

+0.28

+0.25

-0.89

-0.45

-0.31

-0.32

-0.14

+0.66 05H 05H 05H 05H 03H 03H 03H 03H 01H 01H 01H 01H 01H 01H 06H 06H 07H 07H 07H 07H 01H 01H 03H 03H 03H 03H 07H 07H 02H 02H 02H 02H 02H 02H 02H 02H 01H 01H 07H 07H 07H 07H 06H 06H 05H 05H 06C 06C 05H 05H 03H 03H 03H 03H 05H 05H 01H 01H 01H 01H 03H 03H 03H 03H 05H 05H 05H 05H 05H 05H 06H 06H 06H 06H 02H 02H 03H 03H 05H 05H 07H 07H 01H 01H 06H 06H 01H 01H 01H 01H 02H 02H 02H 02H 03H 03H 03H 03H 02H 02H 05H 05H 05H 05H 94 94 129 129 64 64 64 122 105 105 104 108 108 108 95 95.

95 95 117 129 104 108 99 87 127 127 127 113 99 100 100 100 127 64 64 64 104 100 100 100 100 129 64 64 115 115 115 68 68 100 100 100 HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P

St. Lucie Unit 2 Docket Ns. 50-389 Areva NP L-2007-076 Attachment Page 43 of 92 6/7/2006 9:12 AM Component: S/G B Customer Name: St. Lucie Unit 2 Page 8 of 20 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG 31 149 0.27 31 153 0.18 32 144 0.13 0.24 0.18 0.15 32 148 0.15 0.29 33 49 0.28 33 147 0.40 33 159 0.14 34 22 0.44 0.41 34 24 0.31 0.47 0.34 0.29 0.27 34 26 0.54 0.16 0.22 34 28 0.44 0.62 34 64 0.07 0.37 34 68 1.17 34 100 1.06 34 120 0.24 0.15 34 140 0.13 0.17 0.14 0.49 34 156 0.27 0.39 35 63 0.17 0.25 35 121 0.24 35 131 0.33 36 56 0.33 0.21 36 130 0.21 37 157 0.39 0.11 37 159 0.20 38 24 0.23 38 26 0.09.

0.13 38 28 0.24 38 34 0.45 38 42 0.25 38 96 0.22 67 P6 68 P6 72 P6 86 P6 85 P6 102 P6 53 P6 79 P6 66 P6 93 P6 83 P6 97 P6 68 P6 85 P6 90 P6 70 P6 69 P6 96 P6 95 P6 76 P6 82 P6 96 P6 93 P6 121 P6 102 P6 96 P2 166 P2 105 P6 103 P6 37 P6 67 P6 82 P6 103 P6 95 P6 115 P6 71 P6 99 P6 125 P6 102 P6 96 P6 84 P6 92 P6 98 P6 81 P6 94 P6 77 P6 122 P6 96 P6 97 P6 104 P6 118 P6 96 P6 SAX SAX SAX SAX SAX SAI SAT SAT SAl SAX SAX SAI SAX SAX SAX MAI-SAI SAT MAI SAI SAT SAI SAT SAI SAI TWD 36 TWD 35 SAT SAT SAI SAT SAI SAI SAI SAI SAT MAI SAT SAT SAT SAI SAI SAT SAI MAI SAT SAT SAT SAT SAT SAT SAT 03H 06H 01H 06H 05H 05C 03H 03H 01H 03H 02H 01H 03H 01H 01H 03H-03H 05H 01H 01H 02H 01H 01H 02H 02H DCB DUB 02H 04H 02H 02H 04H 03H 02H 02H 01H 01H 02H 01H 01H 01H 01H 02H 02H 02H 02H 01H 01H 01H 02H 01H 02H

+0.51

+0.84

+0.87

-0.15

+0.81

+0.84

-o.02

+0.90

-0.23

+0.69

+0.91

+0.30

+0.78

-0.43

+0.71

+0.74

+0.44

+0.70

-0.41

+0.80

+0.85

-0.61

+0.66

-0.39

+0.95

+2.00

+2.00

+0.79

+0.60

-0.61

+0.92

+0.88

+0.77

+0.71

-0.35

-0.88

+0.44

+0.45

+0.61

-0.46

+0.80

-0.52

+0.78

-0.58

+0.82

+0.86

-0.89

+0.66

-0.53

+0.27

-0.58

+0.84 03H 03H 06H 06H 01H 01H 06H 06H 05H 05H 05C 05C 03H 03H 03H 03H 01H 01H 03H 03H 02H 02H 01H 01H 03H 03H 01H 01H 01H 01H 03H 03H 03H 03H 05H 05H 01H 01H 01H 01H 02H 02H 01H 01H 01H 01H 02H 02H 02H 02H TEH TEC TEH TEC 02H 02H 04H 04H 02H 02H 02H 02H 04H 04H 03H 03H 02H 02H 02H 02H 01H 01H 01H 01H 02H 02H 01H 01H 01H 01H 01H 01H 01H 01H 02H 02H 02H 02H 02H 02H 02H 02H 01H 01H 01H 01H 01H 01H 02H 02H 01H 01H 02H 02H 100 99 99 99 99 83 100 100 64 100 95 127 127 129 129 129 129 129 129 129 129 129 129 68 68 15 33 122 108 139 139 95 121 99 99 68 68 108 94 68 68 94 99 99 95 129 129 129 129 130 64 113 HOT HOT HOT HOT HOT COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 603UL 600UL 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 44 of 92 Areva NP 6/7/2006 9:12 AM Component: S/G B Customer Name: St. Lucie Unit 2 Page 9 of 20 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS 38 98 0.25 0.22 0.18 0.22 0.16 0.26 38 112 0.46 0.16 0.16 38 134 0.16 38 156 0.26 39 21 0.25 39 25 0.24 39 41 0.29 39 139 0.25 0.14 0.23 0.17 40 6

0.20 40 14 0.16 40 18 0.22 40 62 0.35 0.31 40 68 0.20 40 102 0.30 0.24 0.33 40 128 0.44 40 138 0.18 40 146 0.18 40 148 0.20 40 152 0.19 41 27 0.47 41 55 0.42 41 63 0.21 0.21 0.26 0.10 41 109 0.50 41 113 0.22 0.13 0.15 41 121 0.12 0.41 41 137 0.14 41 147 0.25 41 151 0.34 41 161 0.20 0.27 42 36 0.14 0.20 42 44 0.20 DEG CHN IND %TW LOCATION EXT EXT CAL # LEG 280 P6 106 P6 297 P6 75 P6 99 P6 112 P6 102 P6 72 P6 73 P6 77 P6 99 P6 99 P6 77 P6 94 P6 100 P6 248 P6 80 P6 62 P6 103 P6 102 P6 96 P6 99 P6 109 P6 102 P6 93 P6 83 P6 87 P6 107 P6 79 P6 159 P6 79 P6 59 P6 103 P6 113 P6 101 P6 62 P6 107 P6 97 P6 117 P6 128 P6 115 P6 113 P6 45 P6 106 P6 70 P6 89 P6 88 P6 98 P6 97 P6 62 P6 311 P6 106 P6 SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI' SAI SAI SAI MAI SAI SAI SAI MAI SAI SAI MAI SAI SAI SAI SAI SAI SAI MAI SAI SAI SAI SAI MAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI MAI SAI 01H 03H 03H 06H 06H 06H 01H 02H 02H 02H 02H 05H 05H 03H 03H 03H 03H 04H 01H 02H 02H 01H 01H 01H 01H 01H 05H 01H 04H 02H 03H 03H 01H 01H 01H 01H 05H 05H 05H 01H 01H 01H 01H 01H 02H 03H 02H 02H 02H 01H 01H 02H

+0.27

-0.61

+0.40

-0.42

+0.17

+0.70

+0.29

-0.16

+0.84

+0.81

+0.36

+0.64

+0.86

+0.40

+0.43

-0,.71*

+0.89

-0.15

+0.61

-0.82

-0.79

-0.68

+0.39

+0.80

-0.72

-0.24

-0.13

+0.67

+0.83

-0.60

+0.87

+0.95

-0.48

-0.36

-0.68

+0.57

-0.48

+0.48

-0.42

-0.48

+0.26

+0.58

+0.01

+0.77

+0.51

+0.84

+0.74

-0.73

+0.45

-0.44

+0.46

-0.31 01H 01H 03H 03H 03H 03H 06H 06H 06H 06H 06H 06H 01H 01H 02H 02H 02H 02H 02H 02H 02H 02H 05H 05H 05H 05H 03H 03H 03H 03H 03H 03H 03H 03H 04H 04H 01H 01H 02H 02H 02H 02H 01H 01H 01H 01H 01H 01H 01H 01H 01H 01H 05H 05H 01H 01H 04H 04H 02H 02H 03H 03H 03H 03H 01H 01H 01H 01H 01H 01H 01H 01H 05H 05H 05H 05H 05H 05H 01H 01H 01H 01H 01H 01H 01H 01H 01H 01H 02H 02H 03H 03H 02H 02H 02H 02H 02H 02H 01H 01H 01H 01H 02H 02H 133 133 133 113 113 113 113 113 113 95 99 127 129 64 95 95 95 95 127 127 127 68 68 67 113 113 113 108 95 100 100 100 129 68 115 115 68 68 114 114 114 114 108 108 95 100 100 95 95 130 130 64 HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 58039 5803P 5803P 5803P 5803P 5803P 5803P 5803P 58039 58039 5803P 5803P 5803P 5803P 5803P

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 45 of 92 Areva NP 6/7/2006 9:12 AM Component: S/G B Customer Name: St. Lucie Unit 2 Page 10 of 20 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS 0.36 42 52 0.13 42 56 0.21 0.22 0.50 0.11 42 142 0.13 42 150 0.21 0.26 43 45 0.34 0.50 43 71 0.13 43 93 2.05 44 22 0.13 44 28 0.21 44

52.

0.22-0.25 0.37 44 60 0.17 44 70 0.26 0.25 44 122 0.27 0.23 44 128 0.40 44 132 0.24 44 144 0.27 45 25 0.66 45 37 0.27 45 107 0.38 45 151 0.14 46 60 0.23 0.36 0.34 47 43 0.58 0.26 47 103 0.18 0.12 47 117 0.22 0.22 47 121 0.23 47 151 0.51 0.28 47 157 0.43 48 22 0.23 0.26 48 24 0.18 0.33 48 26 0.23 0.35 48 28 0.58 48 40 0.29 0.17 DEG 109 90 109 126 110 77 40 99 63 100 102 61 14 63 141 79 112 106 121 112 48 96 69 84 125 80 94 276 102 56 101 86 97 107 103 70 85 136 144 73 108 73 88 99 84 122 79 71 89 100 90 108 CHN P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P4 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 IND %TW LOCATION EXT EXT CAL # LEG MAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI TWD 48 SAI SAI MAI SAI MAI SAI SAI SAI SAI SAI MAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI 02H

+0.24 02H

+0.86 04H

-0.25 04H

+0.78 05H

+0.52 05H

-0.80 02H

-0.48 02H

+0.28 02H

-0.22 01H

-0.39 04H

+0.47 02H

+0.91 DHT

+0.00 05H

+0.69 02H

+0.25 01H

+0.03 02H

-0.09 02H

+0.48 01H

-0.40 05H

+0.83 05H

-0.25 01H

-0.38 03H

+0.84 01H

+0.60 02H

+0.34 02H

+0.28 01H

+0.48 04H

+0.91 01H

+0.52 02H

+0.74 01H

-0.61 01H

+0.94 05H

+0.85 02H

+0.66 04H

+0.45 02H

+0.61 02H

+0.87 01H

+0.32 04H

-0.22 01H

+0.83 02H

-0.32 02H

+0.64 02H

-0.41 05H

+0.45 01H

-0.73 01H

-0.66 02H

+0.39 01H

-0.69 01H

+0.70 01H

-0.52 01H

-0.21 01H

+0.53 02H 02H 04H 04H 05H 05H 02H 02H 02H 01H 04H 02H TEH 05H 02H 01H 02H 02H 01H 05H 05H 01H 03H 01H 02H 02H 01H 04H 01H 02H 01H 01H 05H 02H 04H 02H 02H 01H 04H 01H 02H 02H 02H 05H 01H 01H 02H 01H 01H 01H 01H 01H 02H 02H 04H 04H 05H 05H 02H 02H 02H 01H 04H 02H TEC 05H 02H 01H 02H 02H 01H 05H 05H 01H 03H 01H 02H 02H 01H 04H 01H 02H 01H 01H 05H 02H 04H 02H 02H 01H 04H 01H 02H 02H 02H 05H 01H 01H 02H 01H 01H 01H 01H 01H 64 68 68 68 68 68 99 99 99 64 64 61 15 127 129 115 68 68 68 61 61 122 108 108 94 99 129 130 114 99 68 68 68 67 67 113 113 124 104 109 99 99 95 160 161 129 129 129 129 129 64 64 HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD!

HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 46 of 92 Areva N?

6/7/2006 9:12 AM Component: S/G B Customer Name: St.

Lucie Unit 2 Page 11 of 20 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 48 84 2.85 1.47 1.59 48 90 0.30 0.20 48 92 0.58 0.35 48 98 0.27 0.38 0.35 48 124 0.16 48 138 0.31 0.31 48 148 0.25 0.15 48 150 0.44 0.22 48 158 0.22 0.20 48 160 0.16 49 27 0.19 49 35 0.22 49 51 0.23 49 71 0.42 49 99 0.18 0.23 0.14 0.28 0.19 0.25 49 103 0.25 0.50 49 115 0.34 0.31 0.10 49 133 0.34 49 145 0.22 49 153 0.17 0.14 0.14 0.13 50 34 0.26 50 112 0.14 51 25 0.24 51 139 0.45 51 153 0.25 52 80 1.37 52 84 1.98 52 136 0.27 52 144 0.20 53 15 0.26 106 P4 22 P2 97 P2 83 P6 101 P6 100 P6 103 P6 76 P6 267 P6 90 P6 128 P6 79 P6 101 P6 68 P6 66 P6 95 P6 76 P6 81 P6 286 P6 86 P6 92 P6 79 P6 106 P6 103 P6 67 P6 62 P6 91 P6 80 P6 43 P6 75 P6 108 P6 91 P6 105 P6 87 P6 66 P6 99 P6 72 P6 56 P6 73 P6 81 P6 71 P6 87 P6 62 P6 51 P6 101 P6 79 P6 85 P2 49 P4 51 P6 95 P6 76 P6 TWD 53 TWD 39 TWD 40 SAI MAI MAI SAI SAI SAI SAI SAI SAI SAI MAI SAI SAL SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI MAI SAI SAI SAI SAI TWD 39 TWD 44 SAI SAI SAI DHB DHT DCT 05H 05H 01H 02H 01H 01H 02H 01H 01H 01H 02H 02H

02H, 02H 02H 02H 02H 01H 01H 01H 01H 01H 02H 03H 03H 04H 04H 01H 01H 01H 01H 04H 01H 02H 02H 03H 04H 04H 01H 01H 01H 02H 02H DHB DCT 02H 02H 03H

+0.00

+0.00

+0.42

+0.07

+0.90

+0.02

+0.60

-0.20

+0.47

+0.71

+0.23

-0.69

-0.30

-0.22

+0.76

+0.55

-0.42

+0.26

-0.41

-0.88

+0.45

-0.54

-0.54

-0.78

-0.16

+0.87

-0.10

+0.74

+0.36

+0.67

-0.29

+0.89

-0.57

+0.88

-0.42

-0.67

-0.32

-0.55

+0.89

+0.74

+0.05

+0.73

+0.60

+0.36

+0.30

+0.81

+0.24

-0.20

+0.26

+0.05

+0.67 TEH TEC TEH TEC TEH TEC 05H 05H 05H 05H 01H 01H 02H 02H 01H 01H 01H 01H 02H 02H 01H 01H 01H 01H 01H 01H 02H 02H 02H 02H 02H 02HW 02H 02H 02H 02H 02H 02H 02H 02H 01H 01H 01H 01H 01H 01H 01H 01H 01H 01H 02H 02H 03H 03H 03H 03H 04H 04H 04H 04H 01H 01H 01H 01H 01H 01H 01H 01H 04H 04H 01H 01H 02H 02H 02H 02H 03H 03H 04H 04H 04H 04H 01H 01H 01H 01H 01H 01H 02H 02H 02H 02H TEH TEC TEH TEC 02H 02H 02H 02H 03H 03H 14 14 14 159 159 61 61 133 133 113 108 95 95 99 99

.9 9....

99 95 95 95 129 130 67 61 113 113 113 113 113 113 124 124 104 104 104 94 100 99 99 99 99 130 114 129 95 99 13 16 95 99 127 COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD HOT HOT HOT 600UL 600UL 60OUL 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803?

5803?

5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803?

5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 600UL 600UL 5803P 5803P 5803P 53 27 0.48 105 P6 SAI 01H

-0.46 01H 01H 129 HOT 5803P

St. Lucie Unit 2 L-2007-076 Docket Ns. 50-389 Attachment Page 47 of 92 Areva NP 6/7/2006 9:12 AM Customer Name: St. Lucie Unit 2 Component: S/G B Page 12 of 20 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 0.47 99 P6 SAI 04H

+0.79 04H 04H 129 HOT 5803P 53 39 0.25 79 P6 SAI 01H

+0.75 01H 01H 64 HOT 5803P 53 47 0.51 106 P6 SAI 01H

+0.31 01H 01H 67 HOT 5803P 53 67 0.26 104 P6 SAI 01H

-0.34 01H 01H 67 HOT 5803P 0.18 70 P6 SAI 01H

+0.83 01H 01H 67 HOT 5803P 53 77 0.22 79 P6 MAI 07H

+0.79 07H 07H 61 HOT 5803P 53 119 0.24 79 P6 SAI 02H

+0.76 02H 02H 109 HOT 5803P 53 123 0.25 81 P6 SAI 01H

+0.98 01H 01H 109 HOT 5803P 53 139 0.21 85 P6 SAI 02H

+0.57 02H 02H 95 HOT 5803P 53 143 0.25 90 P6 SAI 02H

+0.81 02H 02H 99 HOT 5803P 0.24 105 P6 SAI 03H

-0.60 03H 03H 99 HOT 5803P 54 40 0.20 110 P6 SAI 01H

-0.36 01H 01H 64 HOT 5803P 0.29 96 P6 SAI 01H

+0.42 01H 01H 64 HOT 5803P 54 42 0.15 89 P6 SAI 01H

-0.51 01H 01H 67 HOT 5803P 54 48 0.18 43 P6 SAI 02H

+0.67 02H 02H 115 HOT 5803P 0.25 88...

P6 SAI 04H

+0.75 04H.04H - 67 HOT 5803P 0.22 93 P6 SAI 06H

-0.63 06H 06H 67 HOT 5803P 54 50 0.41 112 P6 SAI 05H

+0.80 05H 05H 67 HOT 5803P 54 104 0.25 87 P6 SAI 01H

-0.64 01H 01H 124 HOT 5803P 55 31 0.39 97 P6 SAI 01H

+0.53 01H 01H 130 HOT 5803P 55 45 0.16 80 P6 SAI 01H

-0.28 01H 01H 67 HOT 5803P 55 61 0.32 104 P6 SAI 01H

-0.70 01H 01H 68 HOT 5803P 55 85 0.30 90 P6 SAI 04H

+0.90 04H 04H 61 HOT 5803P 55 87 1.11 108 P2 TWD 35 DCT

+0.00 TEH TEC 15 COLD 600UL 55 95 0.29 98 P6 SAI 01H

+0.74 01H 01H 61 HOT 5803P 55 119 0.16 61 P6 SAI 01H

+0.88 01H 01H 109 HOT 5803P 55 121 0.20 66 P6 SAI 01H

+0.88 01H 01H 109 HOT 5803P 55 131 0.30 278 P6 SAI 02H

-0.18 02H 02H 94 HOT 5803P 55 155 0.17 88 P6 SAI 02H

-0.37 02H 02H 99 HOT 5803P 0.17 53 P6 SAI 02H

+0.78 02H 02H 99 HOT 5803P 0.17 56 P6 SAI 02H

+0.47 02H 02H 99 HOT 5803P 56 34 0.31 98 P6 SAI 01H

-0.69 01H 01H 130 HOT 5803P 56 46 0.43 98 P6 SAI 01H

-0.61 01H 01H 67 HOT 5803P 56 52 0.40 61 P6 SAI 01H

-0.13 01H 01H 67 HOT 5803P 56 70 0.27 86 P6 SAI 01H 40.47 01H 01H 61 HOT 5803P 56 114 0.16 74 P6 SAI 01H

-0.52 01H 01H 104 HOT 5803P 0.13 60 P6 SAI 01H

+0.14 01H 01H 104 HOT 5803P 56 116 0.53 92 P6 SAI 01H

+0.81 01H 01H 104 HOT 5803P 56 118 0.19 99 P6 SAI 01H

+0.91 01H 01H 109 HOT 5803P 0.44 104 P6 MAI 02H

+0.47 02H 02H 109 HOT 5803P 56 120 0.35 98 P6 SAI 01H

+0.44 01H 01H 109 HOT 5803P 0.17 69 P6 SAI 02H

+0.93 02H 02H 109 HOT 5803P 56 130 0.41 86 P6 SAI 01H

-0.20 01H 01H 94 HOT 5803P 0.55 109 P6 MAI 02H

+0.42 02H 02H 94 HOT 5803P 56 134 0.35 108 P6 MAI 02H

-0.28 02H 02H 94 HOT 5803P 0.31 131 P6 SAI 03H

-0.73 03H 03H 94 HOT 5803P 56 140 0.15 54 P6 SAI 03H

+0.88 03H 03H 95 HOT 5803P 56 142 0.38 116 P6 SAI 02H

+0.46 024 02H 159 HOT 5803P 0.21 124 P6 SAI 03H

-0.17 03H 03H 159 HOT 5803P 0.17 97 26 SAI 03H

+0.81 03H 03H 159 HOT 5803P 56 146 0.19 65 P6 SAI 03H

-0.56 03H 03H 99 HOT 5803P 56 152 0.17 52 P6 SAI 02H

-0.61 02H 02H 99 HOT 5803P

St. Lucie Unit 2 L-2007-076 Docket Ns. 50-3 89 Attachment Page 48 of 92 Areva NP 6/7/2006 9:12 AM Customer Name: St. Lucie Unit 2 Component: SIC B Page 13 of 20 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL 4 LEG PROBE 0.63 109 P6 SAI 02H

+0.63 02H 02H 99 HOT 5803P 0.30 111 P6 MAI 03H

+0.40 03H 03H 99 HOT 5803P 56 156 0.26 93 P6 SAI 02H

-0.50 02H 02H 99 HOT 5803P 0.13 79 P6 SAI 02H

+0.25 02H 02H 99 HOT 5803P 56 158 0.18 118 P6 SAI 02H

+0.85 02H 02H 95 HOT 5803P 57 83 0.36 71 P6 SAI 01H

+0.23 01H 01H 61 HOT 5803P 0.17 103 P6 SAI 04H

+0.78 04H 04H 61 HOT 5803P 57 91 0.53 95 P6 SAI 04H

+0.27 04H 04H 61 HOT 5803P 57 101 0.25 85 P6 SAI 02H

+0.36 02H 02H 113 HOT 5803P 57 103 0.19 54 P6 SAI 01H

-0.19 01H 01H 114 HOT 5803P 57 123 0.39 91 P6 SAI 01H

+0.56 01H 01H 109 HOT 5803P 0.31 97 P6 SAI 01H

-0.55 01H 01H 109 HOT 5803P 57 141 0.27 84 P6 SAI 02H

+0.78 02H 02H 99 HOT 5803P 58 30 0.48 109 P6 SAI 01H

-0.55 01H 01H 129 HOT 5803P 0.18 69 P6 SAI 01H

+0.43 01H 01H 129 HOT 5803P 0.21 74 P6 SAI 03H

+0.30 03H 03H 129.

HOT 58039...

0.32 99 P6 SAI 04H

+0.72 04H 04H 129 HOT 5803P 58 36 0.55 99 P6 SAI 01H

+0.58 01H 01H 130 HOT 5803P 0.30 70 P6 SAI 02H

+0.76 01H 02H 130 HOT 5803P 58 38 0.24 102 P6 SAI 01H

-0.40 01H 01H 64 HOT 5803P 0.42 85 P6 SAI 01H

-0.18 01H 01H 64 HOT 5803P 0.20 44 P6 SAI 02H

-0.26 02H 02H 64 HOT 5803P 0.22 70 P6 SAI 02H

+0.83 02H 02H 64 HOT 5803P 0.18 59 P6 SAI 04H

+0.91 04H 04H 64 HOT 5803P 58 56 0.21 84 P6 SAI 01H

-0.16 0111 01H 68 HOT 5803P 0.26 94 P6 SAI 05H

+0.25 05H 05H 68 HOT 5803P 58 76 0.22 59 P6 SAI 05H

+0.80 05H 05H 61 HOT 5803P 0.43 87 P6 SAI 02H

+0.70 02H 02H 61 HOT 5803P 58 82 0.35 85 P6 SAI 04C

+0.56 04C 04C 88 COLD 5803P 58 94 0.32 95 P6 SAI 02H

-0.10 02H 02H 61 HOT 5803P 58 136 0.41 105 P6 SAI 02H

-0.60 02H 02H 94 HOT 5803P 0.10 80 P6 SAI 02H

+0.84 02H 02H 94 HOT 5803P 58 144 0.31 138 P6 SAI 04H

+0.36 04H 04H 99 HOT 5803P 59 31 0.61 100 P6 MAI 01H

+0.67 01H 01H.130 HOT 5803P 0.37 93 P6 SAI 02H

-0.66 02H 02H 130 HOT 58039 0.17 58 P6 SAI 02H

+0.74 02H 02H 130 HOT 5803P 59 35 0.14 67 P6 SAI 01H

-0.27 01H 01H 130 HOT 5803P 0.36 103 P6 SAI 01H

+0.40 01H 01H 130 HOT 5803P 59 41 0.24 90 P6 MAI 01H

+0.14 0111 01H 67 HOT 5803P 0.13 46 P6 SAI 01H

+0.36 01H 01H 67 HOT 5803P 0.38 85 P6 SAI 05H

+0.56 05H 05H 67 HOT 5803P 59 57 0.11 39 P6 SAI 01H

-0.44 01H 01H 115 HOT 58039 0.11 61 P6 SAI 01H

+0.89 01H 01H 115 HOT 5803P 0.24 100 P6 SAI 02H

+0.43 02H 02H 115 HOT 5803P 0.31 67 P6 SAI 05H

-0.39 05H 05H 115 HOT 58039 0.15 49 P6 SAI 05H

+0.85 05H 05H 115 HOT 5803P 0.21 91 P6 SAI 03H

+0.93 03H 03H 68 HOT 5803P 59 67 0.43 91 P6 SAI 02H

+0.87 02H 02H 67 HOT 5803P 59 77 0.29 ill P6 MAI 03H

+0.55 03H 03H 61 HOT 5803P 0.37 75 P6 MAI 05H

-0.21 05H 05H 61 HOT 5803P 59 109 0.17 64 P6 SAI 04H

+0.77 04H 04H 114 HOT 5803P 59 151 0.44 83 P6 SAI 02H

-0.68 02H 0211 99 HOT 5803P

St. Lucie Unit 2 Docket Ns. 50-389 Areva NP L-2007-076 Attachment Page 49 of 92 6/7/2006 9:12 AM Component: S/G B Customer Name: St. Lucie Unit 2 Page 14 of 20 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 59 155 0.25 59 157 0.21 60 22 0.27 60 40 0.26 60 50 0.36 60 54 0.36 60 68 0.18 0.17 60 96 0.22 0.15 60 104 0.18 61 25 0.27 0.32 61 27 0.27 61 31 0.50 61 41 0.14 0.14 0.12 0.15 0.19 0.35 0.19 61 43 0.28 61 71 0.26 0.23 61 79 0.38 0.19 0.32 0.19 0.19 61 101 0.39 61 105 0.15 61 109 0.13 0.27 61 I11 0.20 61 119 0.19 0.35 1.11 61 133 0.13 61 147 0.31 62 30 0.54 62 34 0.17 62 38 0.24 62 42 0.16 62 48 0.29 62 62 0.18 0.15 0.16 62 82 0.37 0.30 62 84 0.25 0.14 79 P6 90 P6 95 P6 104 P6 92 P6 88 P6 97 P6 58 P6 61 P6 66 P6 98 P6 98 P6 91 P6 58 P6 92 P6 88 P6 71 P6 72 P6 66 P6 115 P6 91 P6 93 P6 70 P6 103 P6 82 P6 97 P6 109 P6 111 P6 93 P6 95 P6 99 P6 53 P6 63 P6 111 P6 73 P6 61 P6 87 P6 94 P6 77 P6 63 P6 103 P6 108 P6 115 P6 84 P6 120 P6 128 P6 78 P6 87 P6 85 P6 72 P6 106 P6 40 P6 SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI MAI SAI SAI SAI MAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI MAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI MAI SAI SAI 02H 02H 04H 01H 01H 01H 01H 01H 01H 01H 02H 02H 04H 02H 01H 01H 01H 01H 01H 02H 02H 06H 07H 05H 05H 02H 05H 05H 0114 01H 01H 01H 01H 03H 01H 01H 01H 02H 01H 02H 01H 03H 01H 01H 01H 02H 05H 061 01H 01H 06H 06H

-0.61

+0.40

+0.86

+0.44

-0.46

-0.33

+0.38

+0.81

+0.80

-0.22

+0.58

+0.65

+0.85

+0.80

+0.68

-0.60

+0.37

+0.74

+0.90

-0.56

+0.71

+0.85

+0.82

-0.23

+0.73

+0.68

-0.60

+0.76

+0.46

+0.62

+0.50

+0.91

-0.22

+0.77

-0.78

-0.32

+0.57

+0.38

-0.79

+0.77

-0.74

+0.79

+0.71

+0.08

-0.30

+0.58

-0.20

+0.83

-0.57

+0.62

-0.14

+0.80 02H 02H 02H 02H 04H 04H 01H 01H 01H 01H 01H 01H 01H 01H 01H 01H 01H 01H 01H 01H 02H 02H 02H 02H 04H 04H 02H 02H 01H 01H 01H 01H 01H 01H 01H 01H 01H 01H 02H 02H 02H 02H 06H 06H 07H 07H 05H 05H 05H 05H 02H 02H 05H 05H 05H 05H 01H 01H 01H 01H 01H 01H 01H 01H 01H 01H 03H 03H 01H 01H 01H 01H 01H 01H 02H 02H 01H 01H 02H 02H 01H 01H 03H 03H 01H 01H 01H 01H 01H 01H 02H 02H 05H 05H 06H 06H 01H 01H 01H 01H 06H 06H 06H 06H 99 95 127 67 67 68 67 67 61 61 114 142 129 129 130 67 67 67 67 67 67 67 67 61 61 159 159 159 161 161 113 114 114 114 114 109 109 109 94 99 129 130 64 67 67 67 67 67 61 61 61 61 HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 50 of 92 Areva NP 6/7/2006 9:12 AM Component: S/G B Customer Name: St. Lucie Unit 2 Page 15 of 20 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS DEG CHN IND %TW LOCATION 62 100 0.19 67 P6 SAI 62 104 0.12 114 P6 SAI 62 142 0.15 78 P6 SAI 63 43 0.14 41 P6 SAI 0.55 104 P6 SAI 0.16 63 P6 SAX 63 45 0.43 106 P6 SAX 63 53 0.75 95 P6 SAI 63 107 0.19 88 P6 SAI 63 113 0.44 96 P6 SAI 0.20 63 P6 SAI 63 143 0.38 91 P6 SAX 64 44 0.27 95 P6 SAI 64 110 0.25 86 P6 SAI 64 112 0.25 92 P6 SAX 0.23 75 P6 SAX 0.16 46 P6 SAI 64 114 0.25 79 P6 SAI 0.14 42 P6 SAI 0.33 95 P6 SAI 0.38 96 P6 SAI 0.13 82 P6 SAI 64 128 0.56 90 P6 SAI 0.12 88 P6 SAI 64 130 0.14 70 P6 SAI 64 132 0.15 95 P6 SAX 64 134 0.21 77 P6 SAX 65 25 0.39 68 P6 SAI 65 39 0.43 92 P6 SAX 0.20 56 P6 SAX 65 51 0.26 78 P6 SAX 0.61 98 P6 SAX 65 65 0.25 65 P6 SAX 65 69 0.32 106 P6 SAX 0.24 275 P6 SAX 65 91 0.19 101 P6 MAI 0.23 77 P6 SAX 65 117 0.54 94 P6 SAX 66 38 0.34 106 P6 MAI 66 52 0.35 95 P6 SAX 66 64 0.18 93 P6 MAI 66 70 0.36 97 P6 SAI 0.29 116 P6 SAX 66 72 0.24 99 P6 SAI 0.27 290 P6 MAI 66 76 0.27 99 P6 SAI 66 78 0.45 103 P6 SAX 66 80 0.27 67 P6 SAX 0.25 110 P6 MAI 0.39 108 P6 MAI 66 82 0.64 103 P6 SAI 66 102 0.48 79 P6 SAI 02H 02H 01H 01H 01H 01H 01H 01H 01H 01H 01H 03H 01H 01H 01H 01H8 03H 01H 02H 02H 04H 04H 01H 01H 02H 01H 02H 02H 01H 01H 01H 01H 04H 03H 03H 07H 02H 01H 01H 01H 05H 04H 05H 03H 05H 02H 01H 06H 06H 05H 01H 01H

+0.88

+0.63

+0.78

-0.75

+0.05

+0.81

-0.33

-0.79

+0.80

-0.40

+0.49

+0.75

-0.20

-0.59

-0.32

+0.66

+0.87

-0.95

-0.18

+0.80

-0.19

+0.74

-0.06

+0.85

+0.93

+0.26

+0.84

+0.90

-0.32

+0.78

-0.54

+0.41

+0.76

-0.65

+0.72

-0. 38

+0.90

-0.41

-0.21

-0.20

+0.20

+0.89

-0.40

+0.82

+0.21

+0.15

-0.71

-0.56

+0.84

+0.20

+0.25

+0.21 EXT EXT CAL # LEG 02H 02H 113 HOT 02H 02H 114 HOT 01H 01H 99 HOT 01H 01H 67 HOT 01H 01H 67 HOT 01H 01H 67 HOT 01H 01H 67 HOT 01H 01H 67 HOT 01H 01H 114 HOT 01H 01H 104 HOT 01H 01H 104 HOT 03H 03H 99 HOT 01H 01H 67 HOT 01H 01H 114 HOT 01H 01H 104 HOT 01H 01H-104 HOT 038 03H 104 HOT 01H 01H 124 HOT 02H 02H 104 HOT 02H 02H 104 HOT 04H 04H 104 HOT 04H 04H 104 HOT 01H 01H 109 HOT 01H 01H 109 HOT 02H 02H 94 HOT 01H 01H 94 HOT 02H 02H 94 HOT 02H 02H 129 HOT 01H 01H 64 HOT 01H 01H 64 HOT 01H 01H 67 HOT 01H 01H 67 HOT 04H 04H 67 HOT 03H 03H 61 HOT 03H 03H 61 HOT 07H 07H 61 HOT 02H 02H 115 HOT 01H 01H 109 HOT 01H 01H 64 HOT 01H 01H 67 HOT 05H 05H 67 HOT 04H 04H 61 HOT 05H 05H 61 HOT 03H 03H 61 HOT 05H 05H 115 HOT 02H 02H 61 HOT 01H 01H 61 HOT 06H 06H 61 HOT 06H 06H 61 HOT 05H 05H 115 HOT 01H 01H 61 HOT 01H 01H 114 HOT PROBE 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P.

5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P

St. Lucie Unit 2 L-2007-076 Docket Ns. 50-389 Attachment Page 51 of 92 Areva NP 6/7/2006 9:12 Am Customer Name: St.

Lucie Unit 2 Component: S/G B Page 16 of 20 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 66 112 0.45 100 P6 SAI 01H

-0.33 01H 01H 104 HOT 5803P 66 126 0.49 98 P6 SAI 01H

+0.34 01H 01H 109 HOT 5803P 67 25 0.22 102 P6 SAI 02H

-0.28 02H 02H 129 HOT 5803P 0.23 83 P6 MAI 02H

+0.76 02H 02H 129 HOT 5803P 67 35 0.20 259 P6 MAI 01H

+0.07 01H 01H 130 HOT 5803P 67 39 0.27 91 P6 SAI 04H

+0.78 04H 04H 64 HOT 5803P 67 61 0.37 103 P6 MAI 01H

-0.17 01H 01H 67 HOT 5803P 67 125 0.36 85 P6 SAI 01H

-0.56 01H 01H 109 HOT 5803P 68 26 0.20 96 P6 SAI 01H

+0.76 01H 01H 129 HOT 5803P 0.29 95 P6 SAI 02H

+0.80 02H 02H 129 HOT 5803P 68 40 0.13 67 P6 SAI 01H

-0.70 01H 01H 67 HOT 5803P 0.24 118 P6 SAI 01H

-0.20 01H 01H 67 HOT 5803P 0.19 83 P6 SAI 01H

+0.15 01H 01H 67 HOT 5803P 68 66 0.21 85 P6 SAI 03H

+0.74 03H 03H 67 HOT 5803P 68 98 0.18 85 P6 SAI 06H

+0.93 06H 06H 61 HOT 5803P 0.40 83 P6 SAI 04H

-0.38 04H 04H 113 HOT.

5803P-0.16 78 P6 SAI 04H

+0.35 04H 04H 113 HOT 5803P 68 132 0.25 100 P6 SAI 03H

-0.20 03H 03H 94 HOT 5803P 69 31 0.20 76 P6 SAI 01H

+0.47 01H 01H 142 HOT 5803P 0.27 94 P6 MAI 02H

+0.88 02H 02H 130 HOT 5803P 69 37 0.22 79 P6 SAI 04H

+0.71 04H 04H 142 HOT 5803P 0.29 76 P6 SAI 02H

+0.73 02H 02H 153 HOT 5803P 69 39 0.33 99 P6 SAI 01H

-0.60 01H 01H 64 HOT 5803P 0.25 254 P6 SAI 02H

+0.65 02H 02H 64 HOT 5803P 69 75 0.41 96 P6 SAI 07H

+0.67 07H 07H 61 HOT 5803P 0.21 107 P6 SAI 03H

-0.34 03H 03H 115 HOT 5803P 0.10 101 P6 SAI 03H

+0.97 03H 03H 115 HOT 5803P 69 97 0.32 90 P6 SAI 01H

+0.03 01H 01H 61 HOT 5803P 0.13 79 P6 SAI 01H

-0.57 01H 01H 61 HOT 5803P 0.43 94 P6 SAI 03H

-0.05 03H 03H 61 HOT 5803P 0.45 99 P6 SAI 04H

+0.65 04H 04H 61 HOT 5803P 69 105 0.29 102 P6 SAI 01H

-0.46 01H 01H 114 HOT 5803P 0.31 87 P6 SAI 01H

+0.87 01H 01H 114 HOT 5803P 69 109 0.15 83 P6 SAI 01H

-0.58 01H 01H 104 HOT 5803P 0.14 79 P6 SAI 01H

+0.39 01H 01H 104 HOT 5803P 69 121 0.24 73 P6 MAI 01H

-0.60 01H 01H 109 HOT 5803P 0.24 72 P6 MAI 02H

+0.15 02H 02H 109 HOT 5803P 69 127 0.26 105 P6 SAI 01H

-0.71 01H 01H 109 HOT 5803P 0.22 94 P6 SAI 01H

+0.61 01H 01H 109 HOT 5803P 69 129 0.65 91 P6 SAI 02H

+0.11 02H 02H 101 HOT 5803P 70 42 0.37 110 P6 SAI 01H

-0.01 01H 01H 67 HOT 5803P 0.40 78 P6 SAI 01H

+0.61 01H 01H 67 HOT 5803P 70 70 0.31 114 P6 SAI 07H

+0.87 07H 07H 61 HOT 5803P 70 138 0.16 85 P6 SAI 02H

+0.78 02H 02H 95 HOT 5803P 71 35 0.44 99 P6 SAI 01H

-0.01 01H 01H 130 HOT 5803P 0.52 99 P6 SAI 01H

+0.64 01H 01H 130 HOT 5803P 71 71 0.20 86 P6 SAI 05H

-0.32 05H 05H 61 HOT 5803P 71 121 0.28 99 P6 SAI 02H

+0.79 02H 02H 109 HOT 5803P 71 123 0.25 112 P6 SAI 03H

+0.96 03H 03H 110 HOT 5803P 71 127 0.38 99 P6 SAI 02H

-0.08 02H 02H 109 HOT 5803P 72 44 0.17 70 P6 SAI 01H

+0.03 01H 01H 67 HOT 5803P 0.11 126 P6 SAI 01H

+0.45 01H 01H 67 HOT 5803P

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 52 of 92 Areva NP 6/7/2006 9:12 AM Component: S/G B Customer Name: St. Lucie Unit 2 Page 17 of 20 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS 0.14 72 46 0.37 72 116 0.26 72 120 0.25 72 122 0.17 72 128 0.39 73 23 0.29 0.16 73 41 0.11 74 24 0.29 74 46 0.18 74 52 0.62 74 60 0.12 0.16 74 62 0.30 0.17 74 70 0.22 74 110 0.26 74 118 0.16 0.41 74 128 0.44 74 132 0.19 0.20 74 136 0.23 75 23 0.36 0.21 0.23 75 31 0.46 0.28 75 119 0.27 75 123 0.25 75 127 0.43 76 88 0.21 77 99 0.21 0.16 77 131 0.31 0.31 78 106 0.13 0.29 80 28 0.38 80 72 0.21 80 136 0.20 82 132 0.21 83 63 0.24 0.16 83 101 0.45 0.17 83 107 0.21 0.19 84 92 0.15 84 96 0.13 84 120 0.21 DEG CHN IND %TW LOCATION EXT EXT CAL # LEG 98 P6 SAl 106 P6 SAI 65 P6 MAI 76 P6 SAl 113 P6 SAI 103 P6 SAI 87 P6 SAI 96 P6 SAI 95 P6 SAI 81 P6 SAI 55 P6 SAI 111 P6 SAI 84 P6 SAl 75 P6 SAI 95 P6 SAT 89 P6 SAI-84 P6 SAl 93 P6 SAT 138 P6 MAI 103 P6 SAl 106 P6 MAI 79 P6 SAl 75 P6 SAl 89 P6 SAl 95 P6 SAl 64 P6 SAl 92 P6 SAl 102 P6 SAl 97 P6 SAT 72 P6 SAl 86 P6 SAT 86 P6 SAI 112 P6 SAI 94 P6 SAI 92 P6 SAI 92 P6 SAI 96 P6 SAI 83 P6 SAI 117 P6 SAI 99 P6 SAl 85 P6 SAI 81 P6 SAI 68 P6 SAT 43 P6 SAI 39 P6 MAI 102 P6 MAI 67 P6 SAl 90 P6 SAl 78 P6 SAI 30 P6 SAl 69 P6 SAI 99 P6 SAl 01H 01H 01H 02H 01H 01H 04H 05H 01H 02H 01H 01H 01H 01H 05H 05K 05H 01H 01H 02H 02H 02H 02H 02H 02H 02H 04H 05H 05H 01H 02H 01H 01H 02H 03H 01H 02H 01H 01H 02H 01H 03H 01H 01H 01H 01H 02H 01H 02H 03H 01H 03H

+0.81

-0.20

+0.46

+0.95

-0.59

+0.51

+0.68

+0.78

-0.50

+0.77

-0.58

-0.52

-0.64

+0.66

-0.33

+0..82.

+0.80

-0.10

+0.60

+0.68

+0.23

-0.42

+0.76

+0.73

-0.67

+0.68

+0.73

+0.48

-0.49

+0.36

+0.73

-0.72

+0.68

+0.50

+0.94

+0.42

+0.85

+0.89

-0.23

+0.01

-0.10

+0.87

-0.43

-0.47

+0.29

+0.15

+0.86

+0.78

+0.77

+0.80

+0.89

+0.79 01H 01H 67 01H 01H 67 01H 01H 110 02H 02H 109 01H 01H 110 01H 01H 109 04H 04H 127 05H 05H 127 01H 01H 67 02H 02H 129 01H 01H 115 01H 01H 67 01H 01H 67 01H 01H 67 05H 05H 67 05H 05H.

67 05H 05H 61 01H 01H 124 01H 01H 110 02H 02H 110 02H 02H 109 02H 02H 94 02H 02H 94 02H 02H 94 02H 02H 127 02H 02H 127 04H 04H 127 05H 05H 130 05H 05H 130 01H 01H 110 02H 02H 110 01H 01H 109 01H 01H 61 02H 02H 61 03H 03H 61 01H 01H 94 02H 02H 94 01H 01H 114 01H 01H 114 02H 02H 129 01H 01H 61 03H 03H 95 01H 01H 109 01H 01H 126 01H 01H 126 01H 01H 114 02H 02H 114 01H 01H 124 02H 02H 114 03H 03H 120 01H 01H 120 03H 03H 110 HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT-HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P.

5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P

St. Lucie Unit 2 Docket Ns. 50-389 Areva NP L-2007-076 Attachment Page 53 of 92 6/7/2006 9:12 AM Component: S/G B Customer Name: St. Lucie Unit 2 Page 18 of 20 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS DEG CHN IND %TW LOCATION 85 91 0.23 86 130 0.17 87 37 0.16 87 93 0.12 87 97 0.17 0.29 87 103 0.35 87 111 0.13 88 106 0.18 88 124 0.14 89 141 0.19 93 59 0.29 93 63 0.29 93 109 0.13 0.10 96 60 0.22.

97 99 0.21 97 129 0.37 98 86 0.33 98 102 0.16 0.15 98 110 0.17 98 114 0.16 0.14 0.14 99 99 0.34 100 96 1.11 101 65 0.25 101 93 0.14 103 93 0.26 0.39 0.19 103 103 0.17 0.32 103 107 0.10 0.28 103 109 0.22 0.20 0.24 0.28 103 111 0.17 0.15 0.16 104 76 0.36 104 80 0.19 0.23 104 88 0.13 104 122 0.20 104 124 0.18 105 65 0.38 105 107 0.22 105 109 0.29 73 P6 S5 84 P6 S1 93 P6 S1 249 P6 S1 267 P6 S1 91 P6 S) 104 P6 S1 69 P6 S1 83 P6 MI 65 P6 S2 132 P6 S1 107 P6 S1 99 P6 S1 50 P6 S1 75 P6 S1

93.

P6 S1 85 P6 S1 100 P6 S) 107 P6 M) 64 P6 S1 64 P6 S2 118 P6 S) 97 P6 S) 88 P6 S) 74 P6 S1 103 P6 S1 88 P6 M) 65 P6 SI 284 P6 S1 88 P6 S) 104 P6 S) 64 P6 SI 103 P6 S1 73 P6 S;

101 P6 S2 113 P6 S5 91 P6 S) 89 P6 S1 109 P6 S) 87 P6 S1 61 P6 S) 64 P6

$j 62 P6 SI 92 P6 S) 87 P6 Mi 95 P6 SI 89 P6 S1 103 P6 S) 68 P6 S) 95 P6 S) 70 P6 S1 86 P6 S1 UI 04H Ai 02H UI 04H AI 02H UI 01H AI 02H AI 01H AI 01H

%I 01H AI 05H AI 03H UI 01H UI 01H AI 02H AI 02H A.

01H AI 01H Ui 03H AI 01H AI 04H AI 04H

%I 01H

%I 01H

\\I 01H

%I 02H

%I 01H

\\I 01H AI 01H

%I 02H

%I 01H

%I 01H

%1 021

%I 02H

%I 02H

%I 01H

%I 04H

%I 01H

%I 01H

%I 02H

%I 02H AI 01H

%I 01H

%I 02H

%I 01H

%I 01H

%I 01H Ai 02H

\\I 01H AI 02H

%I 01H

%I 021

\\I 01H

+0.58

+0.71

+0.90

+0.45

-0.27

+0.87

-0.58

+0.43

-0.93

+0.85

+0.81

-0.42

-0.39

+0.42

+1.00

-0.19

-0.46

+0.76

-0.63

-0.13

+0.81

-0.98

+0.26

-0.56

+0.67

+0.32

+0.50

+0.29

+0.80

-0.20

+0.74

+0.65

-0.13

+0.66

-0.91

-0.53

-0.55

+0.42

-0.51

+0.85

-0.67

+0.94

+0.97

+0.46

+0.50

-0.36

+0.84

-0.72

-0.18

-0.46

+0.78

-0.95 EXT EXT CAL # LEG 04H 04H 120 HOT 02H 02H 124 HOT 04H 04H 123 HOT 02H 02H 120 HOT 01H 01H 120 HOT 02H 02H 120 HOT 01H 01H 114 HOT 01H 01H 104 HOT 01H 01H 114 HOT 05H 05H 109 HOT 03H 03H 101 HOT 01H 01H 126 HOT 01H 01H 126 HOT 02H 02H 104 HOT 02H 02H 104 HOT 01H 01H 126 HOT 01H 01H 120 HOT 03H 03H 109 HOT 01H 01H 120 HOT 04H 04H 114 HOT 04H 04H 114 HOT 01H 01H 110 HOT 01H 01H 124 HOT 01H 01H 124 HOT 02H 02H 110 HOT 01H 01H 133 HOT 01H 01H 120 HOT 01H 01H 126 HOT 02H 02H 120 HOT 01H 01H 120 HOT 01H 01H 120 HOT 02H 02H 120 HOT 02H 02H 114 HOT 02H 02H 114 HOT 01H 01H 104 HOT 04H 04H 104 HOT 01H 01H 124 HOT 01H 01H 124 HOT 02H 02H 110 HOT 02H 02H 110 HOT 01H 01H 110 HOT 01H 01H 110 HOT 02H 02H 110 HOT 01H 01H 118 HOT 01H 01H 120 HOT 01H 01H 120 HOT 02H 02H 120 HOT 01H 0114 113 HOT 02H 02H 113 HOT 01H 01H 126 HOT 02H 02H 104 HOT 01H 01H 110 HOT PROBE 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 58032 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 54 of 92 Areva NP 6/7/2006 9:12 AM Component: S/G B Customer Name: St. Lucie Unit 2 Page 19 of 20 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS 0.17 0.24 105 ill 0.41 0.25 105 113 0.19 0.38 0.15 106 58 0.35 106 86 0.38 0.55 106 90 0.37 106 94 0.24 106 100 0.21 106 114 0.26 106 122 0.17 106 126 0.14 107 77 0.26 107 105 0.19 107 111 0.31 108 82 0.22 0.21 108 94 0.25 0.18 108 102 0.14 108 106 0.22 108 124 0.12 109 49 0.33 109 109 0.29 109 125 0.25 0.23 110 114 0.44 110 118 0.18 0.19 110 130 0.25 0.25 111 55 0.32 112 96 0.18 113 109 0.19 113 121 0.33 0.67 113 123 0.23 0.15 114 120 0.39 114 126 0.15 117 95 0.29 117 103 0.32 117 117 0.26 119 93 0.57 120 108 0.23 121 93 0.25 121 123 0.20 0.34 DEG 86 105 90 118 77 103 67 64 280 85 109 82 53 81 95 66.

89 97 79 260 238 90 56 96 87 95 108 96 102 90 103 86 68 302 77 104 254 51 95 87 75 93 92 299 96 101 90 97 83 106 100 272 CHN P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6, P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 IND SA=

SAI SAI SAI SAI SAI SAI SAI SAI MAI SAI SAI SAI MAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI MAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI SAI

%TW LOCATION 01H

-0.34 01H

+0.12 01H

+0.55 01H

-0.33 02H

+0.39 04H

-0.32 04H

+0.82 02H

-0.34 01H

-0.55 01H

+0.05 01H

-0.50 01H

+0.80 01H

-0.91 01H

+0.48 01H

+0.60 01H

+0.76 01H

-0.29 02H

+0.85 02H

+0.39 01H

-0.39 02H

+0.75 01H

-0.32 01H

-0.02 01H

-0.21 01H

-0.59 01H

+0.71 01H

+0.27 02H

-0.27 02H

-0.51 03H

+0.80 01H

-0.47 02H

+0.81 02H

-0.00 01H

+0.80 03H

+0.64 01H

-0.76 04H

+0.84 02H

+0.46 02H

-0.63 02H

+0.28 02H

-0.39 02H

+0.80 02H

+0.35 01H

+0.70 01H

-0.18 02H

+0.62 02H

-0.62 01H

-0.31 02H

+0.43 01H

-0.48 01H

-0.15 02H

-0.47 EXT 01H 01H 01H 01H 02H 04H 04H 02H 01H 01H 01H 01H 01H 01H 01H 01H O1H 02H 02H 01H 02H 01H 01H 01H 01H 01H 01H 02H 02H 03H 01H 021 02H 01H 03H 01H 04H 021 02H 02H 02H 02H 02H 01H 01H 02H 02H 01H 02H 01H 01H 02H EXT 01H 01H 01H 01H 02H 04H 04H 02H 01H 01H 01H 01H 01H 01H 01H 01H 01H 02H 02H 01H 02H 01H 01H 01H 01H 01H 01H 02H 02H 03H 01H 02H 02H 01H 03H 01H 04H 02H 02H 02H 02H 02H 02H 01H 01H 02H 02H 01H 02H 01H 01H 02H CAL #

110 110 110 110 110 110 110 126 120 120 120 120 114 110 113 113 118 104 110 120 120 120 120 104 104 113 123 110 124 113 124 110 110 101 101 126 120 110 113 113 101 101 113 101 120 101 110 120 110 120 101 101 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803?

5803P 5803?

5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803?

5803P 5803P

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 55 of 92 Areva NP 6/7/2006 9:12 AM Component: S/G B Customer Name: St. Lucie Unit 2 Page 20 of 20 Tubes with Bobbin 35-100% TWD or +Point Circ or Axial Indications ROW LINE VOLTS 122 100 0.61 0.10 122 112 0.34 0.14 124 100 0.09 0.33 124 114 0.12 124 118 0.21 126 60 0.27 0.35 126 78 0.18 128 106 0.14 130 86 0.17 136 76 0.20 0.42 0.16 139 77 0.17 0.22 DEG 87 85 ill 70 236 98 97 103 67 79 72 88 61 49 90 73 101 77 CHN P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 P6 IND SAI SAT SAT SAT SAT SAT MAI SAT SAT SAT SAI SAT SAT SAT SAT SAT SAT SAT

%TW LOCATION 02H

+0.58 05H

-0.48 02H

+0.66 04H

+0.63 02H

+0.70 02H

-0.41 02H

+0.36 02H

+0.37 02H

-0.19 02H

+0.77 05H

+0.27 02H

+0.52 01H

+0.88 02H

-0.82 02H

+0.05 02H...

+0.82 -

01H

-0.41 01H

+0.78 EXT 02H4 0514 0214 0414 0214 0214 02H1 02H4 0214 0214 0514 0214 0114 0214 0214 02 H 0114 0114 EXT 02H 05H 02H 04H 02H 02H 02H 02H 02H 02H 05H 02H 01H 02H 02H 02H _

01Dl 01H CAL #

101 101 101 101 101 101 101 101 126 126 118 101 120 133 133 133--

133 133 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P 5803P.-

5803P 5803P Total Tubes

622 Total Records:

1006

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 56 of 92 Areva NP 6/7/2006 9:14 AM Comoonent: S/G B Page 1 of 1 Customer Name: St. Lucie Unit 2 Tubes with Wear Indications >35% to 39% Preventively Plugged (PTP)

ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 34 68 34 100 48 84 52 80 55 87 1.17 1.06 1.47 1.37 1.11 96 P2 TWD 36 DCB 166 P2 TWD 35 DHB 22 P2 TWD 39 DHT 85 P2 TWD 39 DHB 108 P2 TWD 35 DCT

+2.00

+2.00

+0.00

+0.24

+0.00 TEH TEC 15 TEH TEC 33 TEH TEC 14 TEH TEC 13 TEH TEC 15 COLD COLD COLD COLD COLD 600UL 600UL 600UL 600UL 6O0UL Total Tubes

5 Total Records: 5 Definitions:

PTP Preventative Tube Plug Note: The tube located at Row 48 Line 84 was plugged due to two mechanical wear indications exceeding740%__through-wal-1..

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 57 of 92 Areva NP 6/7/2006 9:15 AM Component: S/G B Customer Name: St. Lucie Unit 2 Page 1 of 4 Tubes with Bobbin 20-34% TWD Indications ROW LINE VOLTS 94 24 0.43 96 24 0.43 0.64 0.65 0.55 45 25 0.31 96 26 0.40 0.47 99 27 0.43 101 27 0.77 100 28 0.88 95 29 0.51 64 34 0.48 96 34 1.00 116 38 0.41 95 41 0.42 97 41 0.93 0.79 94 44 0.37 43 47 0.51 126 48 0.80 93 49 0.48 68 50 0.49 57 51 0.89 41 55 0.46 131 55 0.79 132 58 0.70 0.55 49 59 0.47 127 59 0.41 131 59 0.90 133 59 0.49 134 60 0.46 43 61 0.74 133 61 0.52 135 63 0.51 39 65 0.44 34 68 0.38 36 68 0.49 134 68 0.37 39 69 0.58 41 69 0.35 36 70 0.77 0.39 46 70 0.95 35 71 0.81 0.63 37 71 0.76 45 71 0.35 0.74 97 71 0.42 50 72 0.35 43 75 0.48 DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 73 P2 147 P2 100 P2 126 P2 120 P2 145 P2 25 P2 26 P2 105 P2 108 P2 116 P2 90 P2 30 P2 102 P2 56 P2 123 P2 73 P2 93 P2 151 P2 119 P2 59 P2 106 P2 121 P2 70 P2 69 P2 78 P2 71 P2 94 P2 133 P2 23 P2 79 P2 43 P2 87 P2 48 P2 133 P2 32 P2 35 P2 76 P2 52 P2 119 P2 107 P2 139 P2 117 P2 140 P2 127 P2 42 P2 132 P2 37 P2 143 P2 128 P2 99 P2 153 P2 37 P2 TWD 20 TWD 22 TWO 27 TWD 27 TWD 25 TWD 25 TWD 21 TWD 23 TWD 20 TWD 29 TWD 31 TWD 24 TWD 23 TWD 32 TWD 21 TWD 21 TWD 30.

TWD 28 TWD 20 TWD 24 TWO 30 TWD 23 TWD 24 TWD 33 TWD 24 TWD 30 TWD 29 TWD 25 TWD 24 TWD 21 TWD 30 TWD 24 TWD 23 TWD 27 TWD 24 TWD 24 TWD 22 TWD 20 TWD 24 TWD 20 TWD 23 TWD 20 TWD 31 TWD 22 TWD 34 TWD 28 TWD 24 TWD 31 TWD 20 TWD 31 TWD 20 TWD 20 TWO 20 DCB 07H 08H VS4 DCB VS3 VS4 DHT 08H DCT DCT DCT VS4 VS2 VS3 VS2 VS2 VS4 VS4 VS3 DHT VS2 VS3 VS3 VS3 DCB VS1 DCB VS3 09H DCT DCB DHB VS3 DHT DHT VS3 DHB VS3 DHB VS3 07C DCB DHB VS3 DHT DCB DHT VS3 DCT VS4 VS3 DCB

+0.00

-0.24

-0.88

+0.82

+0.00

-0.90

+0.26

+0.00

-0.26

+0.00

+0.00

+0.00

-0.24

-0.70

+0.90

+0.73

+0.73

+0.73

-1.08

-0.91

+0.00

-0.75

-1.08

-0.93

+0.79

+0.00

-0.85

+0.47

-0.89

+0.90

+0.00

+0.00

+0.45

+0.70

-0.24

+0.00

-0.81

+0.00

+0.98

+0.00

+0.81

-0.79

+0.00

+0.00

+0.80

+0.00

+0.00

+0.00

-0.83

+0.00

+0.75

-0.85

+0.13 TEN TEC TEN TEC TER TEC TEN TEC TEN TEC TEC TER TEN TEC TEN TEC TEN TEC TEN TEC TER TEC TEN TEC TEC TEN TEN TEC TER TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC TEN TEC TEN TEC TER TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TER TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC TEN TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TER TEC TEN TEC TEN TEC 53 52 52 52 52 106 52 52 53 52 52 52 112 52 52 54 55.,

55 54 20 54 54 19 19 19 59 59 59 17 59 60 59 59 18 59 59 15 15 16 59 14 13 13 13 13 14 14 13 13 13 45 13 14 COLD COLD COLD COLD COLD HOT COLD COLD COLD COLD COLD COLD HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 6000L 600UL 600UL 600UL 60OUL 600UL 600UL 60OUL 600UL 600UL 6000L 600UL 600UL 600UL 600UL 6000L 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 58 of 92 Areva NP 6/7/2006 9:15 AM Component: S/G B Customer Name: St. Lucie Unit 2 Page 2 of 4 Tubes with Bobbin 20-34% TWD Indications ROW LINE VOLTS 44 76 1.08 46 76 0.34 52 76 0.79 56 76 0.63 55 77 0.87 52 78 0.70 0.75 54 78 0.63 0.38 0.80 88 78 0.55 96 78 0.89 0.39 51 79 0.56 0.47 50 80 0.61 0.55 52 80 0.51 0.72 0.51 60 80 0.59 51 81 0.71 53 81 0.46 48 82 0.59 50 82 0.37 51 83 0.98 0.68 89 83 1.00 50 84 0.41 0.88 54 84 0.48 88 84 0.48 57 85 0.48 54 86 0.41 88 86 0.61 52 88 0.52 0.90 0.65 54 88 0.56 62 88 0.60 100 88 0.46 51 89 0.76 89 89 0.33 52 90 0.42 54 90 0.48 56 90 0.65 44 92 0.65 0.65 0.75 50 92 0.51 54 92 0.98 43 93 0.54 0.43 DEG 99 62 95 83 125 128 38 113 153 55 87 77 48 145 163 115 18 143 127 115 46 141 103 12 138 14 50 90 26 125 98 137 136 104 134 35 108 65 62 59 165 94 146 36 73 97 59 40 9

38 74 108 33 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 22 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWD 33 TWD 20 TWD 28 TWD 24 TWD 29 TWD 26 TWD 27 TWD 29 TWD 21 TWD 32 TWD 24 TWD 32 TWD 22 TWD 27 TWD 24 TWD 23 TWD 22 TWO 26 TWD 30 TWD 25 TWD 23 TWD 26 TWD 24 TWD 23 TWD 21 TWD 31 TWD 25 TWD 34 TWD 22 TWD 33 TWD 22 TWD 24 TWO 22 TWO 20 TWO 27 TWD 23 TWD 32 TWD 27 TWD 24 TWD 25 TWD 25 TWD 29 TWD 21 TWD 22 TWD 22 TWD 27 TWD 27 TWD 27 TWD 29 TWD 23 TWD 33 TWD 24 TWD 21 LOCATION DHB

+0.00 DHB

+0.38 VS3

+0.86 VS3

+0.79 DCB

+0.00 VS3

+0.77 DCT

+0.00 DHB

+0.00 DCT

+0.00 DCB

+0.00 VS2

+0.93 VS2

-0.98 VS4

+0.62 DCB

+0.42 DHT

+0.00 DHB

+0.00 DCT

+0.00 VS3

-0.85 VS3

+0.68 DCT

+0.00 DCB

+0.00 DCB

+0.00 DCT

+0.00 DHT

+0.00 DCB

+0.33 DCT

+0.00 DCB

+0.00 VS3

-1.00 DHT

+0.00 DCT

+0.00 DCT

+0.00 VS2

+0.83 DCB

+0.00 DCT

+0.00 VS3

+0.77 DHT

+0.00 VS3

+0.88 DCB

+0.39 VS3

+0.77 VS3

-0.74 08C

-0.94 DHB

+0.00 VS2

-1.16 DCB

-0.07 DCB

+0.00 DCT

+0.00 DHB

+0.00 DCT

+0.00 DHT

+0.00 DHB

+0.00 VS3

+0.57 DCB

+0.00 DHB

+0.09 EXT TEN TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEN TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH EXT T EC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC CAL #

14 13 14 14 14 14 14 13 13 13 46 47 47 13 13 14 14 13 13 13 14 14 13 14 13 14 14 47 13 13 15 47 15 15 69 15 15 15 15 15 49 15 49 16 15 15 15 15 15 15 15 15 15 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 60OUL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 60OUL 60OUL 60OUL 600UL 60OUL

St, Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 59 of 92 Areva NP 6/7/2006 9:15 AM Component: S/G B Customer Name: St. Lucie Unit 2 Page 3 of 4 Tubes with Bobbin 20-34% TWD Indications ROW LINE VOLTS 42 94 1.08 44 94 0.44 46 94 0.75 0.73 50 94 0.46 51 95 0.39 95 95 0.33 46 96 0.41 35 97 0.66 45 97 0.40 71 97 0.61 93 97 0.38 34 98 0.78 0.56 0.58 0.53 0.64 0.69 37 99 0.59 1.02 0.58 0.73 94 100 0.90 0.89 33 101 0.43 35 101 0.54 47 101 0.37 93 101 0.64 135 101 0.89 34 102 0.43 29 103 0.43 34 104 0.32 40 104 0.73 47 105 0.32 0.37 32 106 0.47 50 106 0.44 34 108 0.51 96 108 0.60 97 109 0.46 89 111 0.76 96 114 0.91 0.78 0.46 0.61 0.57 52 116 0.46 89 117 0.55 51 121 0.28 54 124 0.65 94 124 0.41 55 125 0.92 94 126 0.51 DEG 104 33 112 140 60 127 122 152 52 146 123 108 30 169 119 112 37 67 51 124 64 47 115 71 115 56 44 51 76 67 51 29 154 41 66 74 92 60 137 23 73 113 70 64 55 65 29 110 159 22 97 108 ill CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND

%TW TWD 34 TWD 21 TWD 29 TWD 29 TWD 23 TWD 21 TWD 21 TWD 20 TWD 26 TWD 20 TWD 27 TWD 23 TWD 29 TWD 24 TWD 25 TWD 24 TWD26-TWD 27 TWD 25 TWD 32 TWD 25 TWD 28 TWD 31 TWD 30 TWD 20 TWD 27 TWD 22 TWD 26 TWD 29 TWD 24 TWD 20 TWD 20 TWD 28 TWD 20 TWD 22 TWD 22 TWD 21 TWD 26 TWD 24 TWD 20 TWD 29 TWD 30 TWD 27 TWD 20 TWD 24 TWD 23 TWD 22 TWD 23 TWD 20 TWD 27 TWD 21 TWD 31 TWD 23 LOCATION DCB

+1.01 DCB

+0.00 VS3

-0.86 DCB

+0.00 VS3

-1.00 07H

+0.82 VS2

+1.04 DHB

+0.00 DHB

+0.00 VS3

-1.07 VS4

-0.74 VS2

+0.70 DHB

+0.00 DHT

-0.25 VS3

-0.82 VS3

+0.82 DCT.

-0.11 DCB

+0.09 DHB

+0.00 Vs3

-1.04 VS3

-0.45 DCB

+0.00 VS2

-1.22 VS2

+0.67 DCT

+0.00 VS3

-1.11 VS3

+0.83 VS2

-0.95 VS1

+0.66 VS3

+0.70 VS3

-0.89 VS3

-0.96 Vs3

-0.86 VS3

-0.96 VS3

+0.75 VS3

-1.06 VS3

+0.98 VS3

-0.80 Vs2

-0.78 VS2

+0.63 VS4

-0.71 VS2

-0.91 VS2

-0.11 VS2

+0.60 VS3

-0.02 VS4

+0.67 VS3

+0.75 VS2

-1.23 VS3

-0.76 VS3

-0.02 VS2

-1.06 VS3

-0.93 VS2

-1.08 EXT EXT TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH...TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC CAL # LEG 16 COLD 15 COLD 15 COLD 15 COLD 15 COLD 16 COLD 49 COLD 42 COLD 51 COLD 42 COLD 15 COLD 49 COLD 51 COLD 51 COLD 51 COLD 51 COLD 51, COLD.

51 COLD 51 COLD 51 COLD 51 COLD 51 COLD 38 COLD 38 COLD 34 COLD 33 COLD 33 COLD 38 COLD 62 COLD 33 COLD 34 COLD 33 COLD 34 COLD 33 COLD

33.

COLD 32 COLD 32 COLD 31 COLD 41 COLD 41 COLD 40 COLD 41 COLD 41 COLD 41 COLD 41 COLD 41 COLD 29 COLD 38 COLD 29 COLD 27 COLD 36 COLD 28 COLD 35 COLD PROBE 60OUL 600UL 600UL 600UL 60OUL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600 UL.

600UL 60OUL 600UL 600UL 600UL 600UL 60OUL 60OUL 600UL 60OUL 60OUL 60OUL 600UL 600UL 60OUL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL

St. Lucie Unit 2 L-2007-076 Docket Ns. 50-389 Attachment Page 60 of 92 Areva NP 6/7/2006 9:15 AM Customer Name: St. Lucie Unit 2 Component: S/G B Page 4 of 4 Tubes with Bobbin 20-34% TWD Indications ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 54 134 0.40 41 P2 TWD 21 DCB

+3.72 TEH TEC 4

COLD 600UL 60 134 0.59 119 P2 TWD 26 VS3

-0.76 TEH TEC 4

COLD 600UL 89 135 0.46 117 P2 TWD 21 DCB

+0.00 TEH TEC 34 COLD 600UL 94 136 0.48 118 P2 TWD 22 VS4

+0.94 TEH TEC 34 COLD 600UL 108 136 0.50 137 P2 TWD 26 02C

-0.85 TEH TEC 33 COLD 600UL 35 137 0.33 125 P2 TWD 20 DHB

+0.97 TEH TEC 5

COLD 600UL 0.41 35 P2 TWD 22 VS3

-0.96 TEH TEC 5

COLD 600UL 70 138 0.41 128 P2 TWD 21 VS3

+0.91 TEH TEC 4

COLD 600UL 88 138 0.40 144 P2 TWD 22 DCB

+0.11 TEH TEC 33 COLD 600UL 55 139 0.74 44 P2 TWD 30 VS3

+0.75 TEH TEC 5

COLD 600UL 92 142 0.44 105 P2 TWD 21 VS2

+0.73 TEH TEC 34 COLD 600UL 95 143 0.56 106 P2 TWD 27 VS2

-0.69 TEH TEC 33 COLD 600UL 52 146 0.82 108 P2 TWD 23 VS3

-1.02 TEH TEC 6

COLD 600UL 76 146 0.35 57 P2 TWD 20 VS2

+0.64 TEH TEC 3

COLD 600UL 64 152 0.46 105 P2 TWD 23 VS2

-0.67 TEH TEC 4

COLD 60OUL 42 162 0.35 104 P2 TWD 21 01C

+0.96 TEH TEC 7

COLD 600UL 27 163 0.52.

51 P2 TWD 24 VS3.

+0.70 TEH TEC-8 COLD 600UL-12 166 0.39 77 P2 TWD 20 01C

-0.98 TEH TEC 8

COLD 600UL Total Tubes

137 Total Records: 177

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 61 of 92 Areva NP 6/7/2006 9:16 AM Component:

S/G B Customer Name: St. Lucie Unit 2 Page 1 of 8 Tubes with Bobbin 1-19 TWD Indications ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 1

3 0.12 17 P2 TWD 7 1

131 0.12 12 P2 TWD 13 2

126 0.20 158 P2 TWD 12 5

121 0.15 155 P2 TWD 11 6

4 0.28 125 P2 TWD 19 15 133 0.16 72 P2 TWD 11 19 117 0.24 164 P2 TWD 14 20 104 0.25 95 P2 TWD 14 22 64 0.11 147 P2 TWD 9 24 62 0.14 38 P2 TWD 10 24 104 0.32 131 P2 TWD 17 24 106 0.32 135 P2 TWD 17 25 65 0.21 44 P2 TWD 14 25 113 0.25 141 P2 TWD 14 26 104 0.31 135 P2 TWD 19 27 103 0.23 159 P2 TWD 15 28 56 0.11-11, P2.

TWD. 7 28 104 0.23 103 P2 TWD 13 28 106 0.28 37 P2 TWD 15 29 45 0.30 27 P2 TWD 18 29 107 0.21 32 P2 TWD 15 30 102 0.26 126 P2 TWD 17 31 5

0.22 152 P2 TWD 16 31 103 0.30 122 P2 TWD 19 32 4

0.17 153 P2 TWD 13 32 118 0.22 139 P2 TWD 13 33 99 0.40 38 P2 TWD 18 33 151 0.18 40 P2 TWD 12 34 4

0.20 98 P2 TWD 11 34 28 0.10 172 P2 TWD 8 34 100 0.18 28 P2 TWD 12 34 102 0.16 49 P2 TWD 11 34 112 0.27 151 P2 TWD 18 35 69 0.24 141 P2 TWD 11 35 103 0.22 46 P2 TWD 15 35 111 0.20 159 P2 TWD 12 35 163 0.22 20 P2 TWD 14 36 68 0.33 18 P2 TWD 19 36 126 0.20 150 P2 TWD 12 36 162 0.25 73 P2 TWD 15 36 164 0.26 78 P2 TWD 17 37 5

0.41 99 P2 TWD 19 37 101 0.19 142 P2 TWD 11 38 68 0.30 158 P2 TWD 17 38 104 0.26 34 P2 TWD 17 39 15 0.12 176 P2 TWD 8 39 23 0.20 138 P2 TWD 12 39 69 0.21 12 P2 TWD 10 0.26 132 P2 TWD 12 0.34 88 P2 TWD 15 39 95 0.20 15 P2 TWD 13 39 133 0.12 50 P2 TWD 9 39 141 0.26 16 P2 TWD 17 01C

-0.97 04H

+0.86 05C

+0.96 04C

+0.88 07C

+0.22 04H

+0.87 VS3

+0.81 VS3

+0.72 VS3

+0.86 VS3

+0.95 VS3

+0.72 VS3

+0.87 VS3

+0.85 VS3

-0.81 VS3

+0.79 VS3

-0.98 VS3-

-0.94 VS3

+0.82 VS3

+0.76 VS3

-0.54 VS3

+0.68 VS3

+0.85 01C

-0.87 VS3

-0.78 02H

+0.92 VS3

+0.07 DCB

+0.00 VS3

+0.88 02H

-0.66 VS3

-0.93 DCB

+0.20 VS3

-0.94 VS3

-0.80 DCT

+0.00 VS3

-0.80 VS3

-0.76 01H

+0.79 VS3

-1.05 VS3

-1.08 01H

+0.83 01C

+0.15 02H

+0.97 VS3

-0.88 VS3

-0.87 VS3

+0.81 04H

+0.85 VS3

+0.73 DHT

-0.07 VS3

-0.70 DCT

-0.25 DCT

-0.25 VS3

-0.80 VS3

+0.71 07C TEC 68 COLD 600UL 07H TEH 92 HOT 600UL 07C TEC 12 COLD 600UL TEH TEC 9

COLD 600UL TEH TEC 65 COLD 600UL TEH TEC 6

COLD 600UL TEH TEC 30 COLD 600UL TEH TEC 34 COLD 600UL TEH TEC 17 COLD 600UL TEH TEC 17 COLD 600UL TEH TEC 34 COLD 600UL TEH TEC 32 COLD 600UL TEH TEC 16 COLD 600UL TEH TEC 29 COLD 600UL TEH TEC 33 COLD 6000L TEH TEC 33 COLD 600UL TEHTEC

.18 COLD.

600UL-TEH TEC 34 COLD 600UL TEH TEC 32 COLD 600UL TEH TEC 19 COLD 600UL TEH TEC 31 COLD 600UL TEH TEC 33 COLD 600UL TEC TEH 97 HOT 600UL TEH TEC 33 COLD 600UL TEC TEH 97 HOT 600UL TEH TEC 29 COLD 600UL TEH TEC 50 COLD 600UL TEH TEC 6

COLD 600UL TEC TEH 98 HOT 600UL TEC TEN 107 HOT 600UL TEH TEC 33 COLD 600UL TEH TEC 33 COLD 600UL TEH TEC 31 COLD 600UL TEH TEC 14 COLD 600OL TEH TEC 33 COLD 6000L TEH TEC 32 COLD 6000L TEH TEC 8

COLD 600UL TEH TEC 16 COLD 600UL TEH TEC 27 COLD 6000L TEH TEC 8

COLD 600UL TEH TEC 7

COLD 600UL TEC TEN 98 HOT 6000L TEH TEC 34 COLD 600UL TEH TEC 15 COLD 600UL TEH TEC 33 COLD 600UL TEC TEH 103 HOT 600UL TEC TEH 102 HOT 600UL TEH TEC 14 COLD 600UL TEH TEC 14 COLD 600UL TEH TEC 14 COLD 600UL TEH TEC 16 COLD 600UL TEH TEC 4

COLD.

600UL TEH TEC 5

COLD 600UL

St. Lucie Unit 2 Docket Ns. 50-3 89 L-2007-076 Attachment Page 62 of 92 Areva NP 6/7/2006 9:16 AM Component: S/G B Customer Name: St. Lucie Unit 2 Page 2 of 8 Tubes with Bobbin 1-19 TWD Indications ROW LINE VOLTS 40 18 0.17 40 162 0.35 42 30 0.26 42 106 0.14 42 136 0.23 43 33 0.16 44 26 0.29 44 142 0.35 45 75 0.31 46 22 0.25 46 44 0.27 46 66 0.24 46 68 0.21 0.30 46 70 0.15 46 94 0.23 47 21 0.34ý 47 93 0.20 47 99 0.36 48 22 0.14 0.29 48 58 0.16 48 72 0.31 48 74 0.29 48 82 0.19 0.27 48 90 0.30 48 92 0.32 49 59 0.28 50 36 0.30 50 84 0.17 50 88 0.32 0.33 50 98 0.19 50 110 0.24 0.26 51 81 0.27 51 101 0.14 51 107 0.28 51 115 0.25 51 121 0.29 51 125 0.24 52 8

0.41 52 74 0.17 52 78 0.37 0.45 52 116 0.06 52 124 0.28 52 146 0.29 0.22 0.25 53 29 0.17 53 63 0.15 DEG CHN 90 P2 94 P2 152 P2 63 P2 26 P2 150 P2 146 P2 105 P2 112 P2 133 P2 21 P2 52 P2 134 P2 100 P2 25 P2 22 P2 113. P2-18 P2 145 P2 12 P2 96 P2 173 P2 46 P2 174 P2 80 P2 101 P2 127 P2 38 P2 46 P2 133 P2 11 P2 165 P2 13 P2 35 P2 141 P2 137 P2 10 P2 35 P2 75 P2 135 P2 72 P2 69 P2 149 P2 158 P2 100 P2 126 P2 159 P2 79 P2 90 P2 152 P2 113 P2 149 P2 139 P2 IND TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD.

TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW 12 19 17 10 15 14 16 19 19 15 16 15 13 16 11 12 16 11 16 10 17 10 14 18 8

12 18 19 17 15 12 19 19 11 16 17 12 10 15 14 19 14 19 12 16 19 4

16 16 14 10 17 11 LOCATION VS3

-0.98 01C

-0.93 VS3

-0.85 VS3

-0.45 VS3

-0.67 VS3

+0.91 VS3

-0.68 07C

-0.94 DCB

+0.00 VS3

+0.99 VS3

+0.51 VS3

+0.87 VS3

+0.77 DCT

+0.00 DCB

+0.00 DHT

-0.25 VS3"

-0.70 DHT

-0.25 VS3

-0.77 VS3

-0.99 VS3

+0.75 VS3

+0.85 VS3

-0.87 DHB

-0.11 DHB

+0.00 07H

+0.93 DHB

+0.13 DHB

+0.00 VS3

+0.85 VS3

+0.64 DHB

+0.33 DHB

+0.42 DCB

+0.20 VS3

-0.77 VS3

-0.71 VS3

+0.55 DCT

+0.00 VS3

+0.70 VS3

+0.91 VS3

+0.84 VS3

+0.79 VS3

+0.82 01C

-1.07 VS3

+0.77 VS3

-1.09 DCB

+0.00 VS3

-0.96 VS3

-1.06 07C

-0.90 VS3

+0.77 06C

+0.11 VS3

+0.95 VS3

-0.71 EXT TEC TEH TEC TEH TEH TEC TEC TEH TEH TEC TEH TEH TEH TEH TEH TEH TEC TEH TEH TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEH TEH TEH TEH TEH TEH TEH TEH TEC TEH EXT TEH TEC TEH TEC TEC TEH TEH TEC TEC TEH TEC TEC TEC TEC TEC TEC TEH TEC TEC TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEC TEC TEC TEC TEC TEC TEC TEC TEH TEC CAL #

103 8

107 31 5

ill 106 6

13 102 21 16 15 15 13 15 102 15 50 103 103 18 14 13 14 14 16 16 17 ill 13 16 16 43 31 31 14 33 32 29 29 27 98 13 14 14 29 28 6

6 6

106 17 LEG HOT COLD HOT COLD COLD HOT HOT COLD COLD HOT COLD COLD COLD COLD COLD COLD HOT COLD COLD HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT COLD COLD COLD COLD COLD COLD COLD COLD HOT COLD PROBE 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 60OUL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL

St. Lucie Unit 2 Docket Ns. 50-3 89 L-2007-076 Attachment Page 63 of 92 Areva NP 6/7/2006 9:16 AM Component:

S/G B Customer Name: St. Lucie Unit 2 Paqe 3 of 8 Tubes with Bobbin 1-19 TWD Indications ROW LINE VOLTS 53 77 0.20 53 81 0.22 53 83 0.13 53 91 0.20 53 145 0.20 0.20 53 149 0.28 53 151 0.10 54 22 0.30 54 76 0.24 0.21 54 86 0.16 0.28 54 88 0.23 54 90 0.21 0.17 54 92 0.37 0.17 54 118 0.20 54 122 0.13 54 134 0.31 54 144 0.32 54 146 0.32 54 148 0.11 54 154 0.23 55 15 0.05 55 89 0.30 55 99 0.20 55 135 0.35 55 159 0.25 56 76 0.30 56 90 0.35 56 98 0.22 56 138 0.23 0.20 56 142 0.33 57 77 0.27 0.18 0.20 57 137 0.33 0.16 57 155 0.17 58 84 0.22 58 94 0.14 60 10 0.23 60 86 0.22 60 152 0.12 0.21 61 79 0.44 61 155 0.16 62 12 0.21 62 18 0.15 62 46 0.29 DEG 59 176 35 177 108 108 54 51 120 82 125 24 13 142 45 84 27 22 12 129 41 16 9

10 13 177 46 99 127 17 52 54 154 146 149 161 76 95 146 53 134 19 160 74 160 117 107 129 24 77 139 139 54 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWD 13 TWD 15 TWD 9 TWD 13 TWD 13 TWD 13 TWD 18 TWD 7 TWD 17 TWD 15 TWD 14 TWD 9 TWD 15 TWD 12 TWD 12 TWD 10 TWD 19 TWD 9 TWD 12 TWD 9 TWD 18 TWD 19 TWD 19 TWD 8 TWD 14 TWD 3 TWD 16 TWD 11 TWD 19 TWD 15 TWD 13 TWD 18 TWD 13 TWD 15 TWD 14 TWD 19 TWD 17 TWD 12 TWD 13 TWD 18 TWD 11 TWD 12 TWD 12 TWD 10 TWD 16 TWD 14 TWD 9 TWD 13 TWD 18 TWD 8 TWD 11 TWD 10 TWD 17 LOCATIC DCB DHT DCB DCT DCB DCT DHT DCB VS3 VS3 VS3 DCB VS3 VS3 DCT DHT DHT DCT VS3 07C VS3 DCT DCT DCT VS3 04H DHB VS3 DCT DHT VS3 VS3 VS3 VS3 VS3 07C VS3 VS3 DCB VS3 VS3 DCT DCT DCB 02H VS3 VS4 VS3 DCB VS2 01H VS3 VS2 3N

+0.46

-0.09

+3.32

-0.15

+1.95

+0.00

+0.00

+0.17

-0.59

+0.66

-0.74

+0.20

-1.02

-0.76

+0.00

-0.22

-0.20

-0.25

+0.96

-0.99

-0.84

-0.02

+0.00

+0.00

+0.00

+0.83

+0.00

+1.04

+0.04

+0.00

-0.96

-0.29

+0.68

-0.85

+0.80

-0.97

-0.85

+0.59

+0.07

+0.72

-0.86

-0.09

-0.24

+0.25

+0.71

-0.71

-0.81

+0.87

+0.00

+0.97

-0.98

-0.88

+0.74 EXT TEH TEH TEH TEH TEH TEH TEH TEH TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEN TEH TEH TEH TEH TEH TEH TEH TEH TEC TEH TEH TEH TEH TEH TEC TEC TEH EXT TEC TEC TEC TEC TEC TEC TEC TEC TEH TEC TEC TEC TEC TEC TEC TEC TEC..

TEC TEC TEC TEC TEC TEC TEC TEC TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEC TEC TEC TEC TEC TEH TEH TEC CAL #

13 13 13 16 5

5 5

6 102 13 13 15 15 15 15 15 15 15 30 27 4

5 5

4 6

103 15 43 6

8 14 15 42 5

5 3

13 13 13 4

4 5

15 16 97 16 4

4 14 3

98 103 19 LEG COLD0 COLD COLD COLD COLD COLD COLD COLD NOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT COLD COLD COLD COLD COLD HOT HOT COLD PROBE 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 6000L 600UL 600UL

St. Lucie Unit 2 L-2007-076 Docket Ns. 50-389 Attachment Page 64 of 92 Areva NP 6/7/2006 9:16 AM Customer Name: St. Lucie Unit 2 Component: S/G B Page 4 of 8 Tubes with Bobbin 1-19 TWD Indications ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 0.20 80 P2 TWD 13 VS3

+1.02 TEH TEC 19 COLD 600UL 62 98 0.26 154 P2 TWD 16 VS3

-0.69 TEN TEC 16 COLD 600UL 62 124 0.14 156 P2 TWD 9 05C

+0.93 TER TEC 27 COLD 600UL 62 158 0.10 88 P2 TWD 2 VS3

-1.10 TEH TEC 3

COLD 600UL 63 79 0.26 52 P2 TWD 16 DCB

+0.00 TEN TEC 13 COLD 600UL 63 143 0.27 52 P2 TWD 16 VS3

-0.94 TEH TEC 3

COLD 600UL 64 68 0.20 79 P2 TWD 12 VS2

+0.71 TER TEC 15 COLD 600UL 0.08 81 P2 TWD 5 VS4

-0.91 TEN TEC 15 COLD 600UL 64 84 0.19 56 P2 TWD 10 VS3

-0.84 TER TEC 15 COLD 600UL 64 132 0.07 25 P2 TWD 6 03H

+0.82 TEH TEC 4

COLD 600UL 64 152 0.29 50 P2 TWD 17 VS4

-1.07 TEH TEC 4

COLD 600UL 67 29 0.17 169 P2 TWD 12 VS2

-0.80 TEC TEH 107 HOT 600UL 68 50 0.30 70 P2 TWD 17 VS2

+0.84 TEN TEC 19 COLD 600UL 68 136 0.14 19 P2 TWD 10 06H

+0.94 TEN TEC 4

COLD 600UL 69 153 0.15 161 P2 TWD 10 VS4

-0.89 TEN TEC 4

COLD 600UL 71 97 0.27 108 P2 TWD 16 VS2

+0.63 TEN TEC 15 COLD 6000L 73 135 0.23 38 P2 TWD 14' VS3

+0.72 TEH TEC, A

COLD.

600UL 74 46 0.22 137 P2 TWD 14 07H

+1.04 TER TEC 20 COLD 600UL 74 110 0.15 15 P2 TWD 9 05H

+0.93 TEN TEC 32 COLD 600UL 76 146 0.26 53 P2 TWD 16 VS3

+0.88 TEN TEC 3

COLD 600UL 0.17 32 P2 TWD 9 VS4

-0.77 TEN TEC 3

COLD 600UL 77 141 0.28 27 P2 TWD 16 DCT

-0.13 TEN TEC 4

COLD 600UL 80 138 0.30 113 P2 TWD 18 08C

-1.06 TEN TEC 3

COLD 600UL 81 25 0.38 31 P2 TWD 18 DCT

+0.00 TEN TEC 53 COLD 600UL 81 39 0.25 66 P2 TWD 15 VS4

+0.71 TEN TEC 52 COLD 600UL 81 57 0.27 96 P2 TWD 15 VS4

-0.77 TEN TEC 55 COLD 600UL 82 34 0.15 27 P2 TWD 8 VS4

-0.79 TEN TEC 53 COLD 600UL 83 39 0.18 26 P2 TWD 10 VS2

+0.62 TEN TEC 53 COLD 600UL 0.23 14 P2 TWD 13 VS4

+0.64 TEN TEC 53 COLD 600UL 83 55 0.35 169 P2 TWD 19 VS3

-0.37 TEN TEC 54 COLD 600UL 0.22 165 P2 TWD 12 VS4

+0.82 TER TEC 54 COLD 600UL 85 41 0.12 151 P2 TWD 8 VS4

-0.98 TEN TEC 55 COLD 600UL 85 129 0.28 126 P2 TWD 15 DHB

+0.17 TEN TEC 35 COLD 600UL 85 147 0.22 49 P2 TWD 13 VS2

-0.99 TEE TEC 34 COLD 60OUL 86 48 0.31 68 P2 TWD 15 VS2

+0.98 TEN TEC 55 COLD 60OUL 86 148 0.13 162 P2 TWD 9 02C

-0.13 TEN TEC 34 COLD 600UL 87 23 0.39 72 P2 TWD 18 VS2

+0.71 TEN TEC 53 COLD 600UL 87 37 0.23 10 P2 TWD 13 VS2

-0.53 TEN TEC 53 COLD 600UL 0.15 165 P2 TWD 9 VS2

+0.98 TEN TEC 53 COLD 600UL 87 83 0.34 93 P2 TWD 18 VS3

-1.08 TEN TEC 46 COLD 600UL 87 93 0.19 148 P2 TWD 14 VS3

-1.04 TEN TEC 49 COLD 600UL 87 103 0.15 67 P2 TWD 10 VS2

-0.89 TEN TEC 39 COLD 600UL 87 131 0.24 155 P2 TWD 13 VS2

-0.36 TEN TEC 35 COLD 600UL 87 135 0.21 157 P2 TWD 14 VS2

-1.07 TEN TEC 33 COLD 60OUL 0.21 51 P2 TWD 14 VS3

-0.91 TEN TEC 33 COLD 600UL 88 24 0.10 100 P2 TWD 7 VS3

+0.69 TEN TEC 52 COLD 600UL 0.19 104 P2 TWD 12 VS2

+0.62 TEN TEC 52 COLD 600UL 88 28 0.25 107 P2 TWD 15 VS3

+0.86 TEN TEC 52 COLD 600UL 0.06 21 P2 TWD 5 VS3

-0.09 TEN TEC 52 COLD 600UL 88 70 0.20 9

P2 TWD 12 04H

+0.69 TEN TEC 45 COLD 600UL 88 78 0.33 53 P2 TWD 17 VS2

-0.97 TEN TEC 46 COLD 600UL 88 98 0.16 33 P2 TWD 9 06C

+1.01 TEN TEC 48 COLD 600UL 88 108 0.13 11 P2 TWD 7 05H

+0.74 TEN TEC 41 COLD 600UL

St. Lucie Unit 2 L-2007-076 Docket Ns. 50-389 Attachment Page 65 of 92 Areva NP 6/7/2006 9:16 AM Customer Name: St. Lucie Unit 2 Component:

S/G B Page 5 of 8 Tubes with Bobbin 1-19 TWD Indications ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 88 128 0.26 67 P2 TWO 15 08C

-0.88 TEN TEC 36 COLD 600UL 88 134 0.25 92 P2 TWD 15 V02

-0.82 TEH TEC 36 COLD 600UL 89 29 0.42 173 P2 TWD 19 DHT

+0.00 TEH TEC 53 COLD 600UL 89 83 0.13 169 P2 TWD 9 VS2

-0.96 TEH TEC 47 COLD 600UL 89 97 0.21 104 P2 TWD 15 VS4

-0.91 TEH TEC 49 COLD 600UL 89 117 0.20 151 P2 TWD 11 07H

-0.96 TEH TEC 38 COLD 600UL 0.15 139 P2 TWD 9 07H

+0.52 TEH TEC 38 COLD 600UL 89 135 0.16 66 P2 TWD 9 VS2

-0.97 TEH TEC 34 COLD 600UL 0.12 19 P2 TWD 7 VS2

+0.86 TEH TEC 34 COLD 600UL 90 112 0.24 161 P2 TWD 14 06H

+0.94 TEH TEC 40 COLD 600UL 91 25 0.31 132 P2 TWD 16 DCT

-0.12 TEH TEC 53 COLD 600UL 91 27 0.32 106 P2 TWD 16 VS4

-0.98 TEH TEC 53 COLD 600UL 91 29 0.31 120 P2 TWD 17 DCT

+0.00 TEH TEC 52 COLD 600UL 91 101 0.15 93 P2 TWD 9 VS2

-1.00 TEH TEC 39 COLD 600UL 92 24 0.27 142 P2 TWD 16 DCB

+0.00 TEH TEC 52 COLD 600UL 92 28 0.11 148 P2 TWD 8 VS2

+0.86 TEH TEC 52 COLD 600UL 0.18 32 P2 TWD 12.

VS2

-0.71 TEH TEC.

52 COLD 600UL 92 30 0.21 160 P2 TWD 13 VS4

-0.95 TEH TEC 52 COLD 600UL 0.35 146 P2 TWD 19 VS2

+0.75 TEH TEC 52 COLD 600UL 0.10 25 P2 TWD 7

VS2

+0.02 TEH TEC 52 COLD 600UL 0.16 112 P2 TWD 11 07H

+0.87 TEH TEC 52 COLD 600UL 0.23 126 P2 TWD 14 07H

-0.84 TEH TEC 52 COLD 600UL 92 34 0.18 57 P2 TWD 12 08H

+0.93 TEH TEC 52 COLD 60OUL 92 38 0.18 112 P2 TWD 12 08H

-0.99 TEH TEC 52 COLD 600UL 92 92 0.18 64 P2 TWD 10 06H

+0.92 TEH TEC 48 COLD 600UL 92 102 0.24 42 P2 TWD 14 VS2

+0.82 TEH TEC 39 COLD 600UL 92 118 0.31 22 P2 TWD 16 DHB

+0.00 TEH TEC 39 COLD 600UL 93 23 0.20 96 P2 TWD 13 DCT

-0.11 TEH TEC 52 COLD 600UL 93 47 0.23 148 P2 TWD 13 VS2

-0.88 TEH TEC 54 COLD 600UL 93 97 0.22 56 P2 TWD 16 VS4

+0.83 TEH TEC 49 COLD 600UL 93 101 0.35 27 P2 TWD 17 VS3

-0.58 TEH TEC 38 COLD 600UL 93 109 0.14 153 P2 TWD 8 VS2

-0.89 TEH TEC 41 COLD 600UL 93 123 0.17 156 P2 TWD 11 VS3

+0.75 TEH TEC 36 COLD 600UL 93 127 0.15 128 P2 TWD 10 VS3

+0.79 TEH TEC 36 COLD 60OUL 93 129 0.20 48 P2 TWD 12 DCB

+0.00 TEH TEC 36 COLD 600UL 93 139 0.10 56 P2 TWD 6 06H

+0.88 TEH TEC 34 COLD 600UL 94 26 0.36 160 P2 TWD 17 DHT

-0.24 TEH TEC 53 COLD 600OL 0.35 89 P2 TWD 17 VS2

-1.01 TEH TEC 53 COLD 600UL 0.37 134 P2 TWD 18 VS2

+0.95 TEH TEC 53 COLD 600UL 94 36 0.24 153 P2 TWD 13 VS2

-0.79 TEH TEC 53 COLD 600UL 94 44 0.16 16 P2 TWD 8 VS2

-0.77 TEH TEC 54 COLD 600UL 94 98 0.24 54 P2 TWD 13 VS2

+0.77 TEH TEC 48 COLD 600UL 94 100 0.33 79 P2 TWD 17 VS4

+1.06 TEH TEC 38 COLD 60OUL 94 102 0.35 70 P2 TWD 18 VS3

-0.80 TEH TEC 38 COLD 600UL 94 104 0.19 148 P2 TWD 11 08C

+0.88 TEH TEC 38 COLD 600UL 94 122 0.28 56 P2 TWD 16 VS2

-0.95 TEH TEC 36 COLD 600UL 94 124 0.36 103 P2 TWD 19 VS3

-0.86 TEH TEC 36 COLD 600OUL 94 126 0.38 144 P2 TWD 19 VS3

-0.89 TEH TEC 35 COLD 600UL 0.30 154 P2 TWD 16 VS4

+0.84 TEH TEC 35 COLD 600UL 0.29 62 P2 TWD 11 DHB

+0.00 TEH TEC 35 COLD 600UL 94 136 0.12 110 P2 TWD 7 VS4

-0.21 TEH TEC 34 COLD 600UL 94 144 0.28 99 P2 TWD 18 VS2

-0.69 TEH TEC 33 COLD 600UL 0.17 39 P2 TWD 12 VS2

+0.94 TEH TEC 33 COLD 600UL

St. Lucie Unit 2 L-2007-076 Docket Ns. 50-389 Attachment Page 66 of 92 Areva NP 6/7/2006 9:16 AM Customer Name: St. Lucie Unit 2 Component: S/G B Page 6 of 8 Tubes with Bobbin 1-19 TWD Indications ROW LINE VOLTS DEG CHN IND

%TW LOCATION EXT EXT CAL # LEG PROBE 0.09 49 P2 TWD 7 VS3

-1.09 TEN TEC 33 COLD 600UL 0.26 15 P2 TWD 17 VS4

+0.89 TEN TEC 33 COLD 600UL 95 25 0.10 163 P2 TWD 6 05H

+0.90 TEN TEC 53 COLD 600UL 0.22 147 P2 TWD 12 VS4

-0.75 TEN TEC 53 COLD 600UL 95 27 0.22 84 P2 TWD 12 VS4

-0.90 TEN TEC 53 COLD 600UL 95 29 0.17 31 P2 TWD 12 06H

+0.77 TEN TEC 52 COLD 600UL 0.19 31 P2 TWD 12 VS2

+0.82 TEN TEC 52 COLD 600UL 95 41 0.26 56 P2 TWD 14 VS4

+0.99 TEN TEC 54 COLD 600UL 0.20 12 P2 TWD 11 DCB

+0.00 TEN TEC 54 COLD 600UL 95 55 0.27 23 P2 TWD 17 DHB

+0.26 TEN TEC 58 COLD 600UL 95 85 0.26 135 P2 TWD 16 VS2

-0.91 TEN TEC 47 COLD 600UL 95 87 0.28 40 P2 TWD 15 VS3

-0.87 TEN TEC 48 COLD 600UL 95 95 0.26 90 P2 TWD 18 VS4

-0.70 TEN TEC 49 COLD 6000L 95 99 0.24 134 P2 TWD 17 08C

+0.94 TEN TEC 49 COLD 600UL 95 101 0.26 147 P2 TWD 15 08H

+0.87 TEN TEC 39 COLD 600UL 95 113 0.14 143 P2 TWD 9 VS2

+1.00 TEN TEC 40 COLD 600UL 0.18 128 P2 TWD. 1I VS2

-0.44 TEH TEC 40-.

COLD.-

600UL_

95 127 0.23 66 P2 TWD 13 VS2

-0.46 TEN TEC 35 COLD 600UL 95 129 0.15 159 P2 TWD 8 VS2

+0.69 TEN TEC 35 COLD 600UL 95 131 0.40 77 P2 TWD 19 VS2

-0.58 TEN TEC 35 COLD 600UL 96 24 0.16 74 P2 TWD 11 06H

+0.84 TEN TEC 52 COLD 600UL 0.10 157 P2 TWD 7 08H

+0.26 TER TEC 52 COLD 600UL 96 26 0.14 140 P2 TWD 10 VS2

+1.08 TEN TEC 52 COLD 600UL 0.22 15 P2 TWD 14 VS3

-0.89 TEN TEC 52 COLD 600UL 96 30 0.28 29 P2 TWD 16 VS4

+0.86 TEN TEC 52 COLD 600UL 96 34 0.21 57 P2 TWD 14 VS3

+0.47 TEN TEC 52 COLD 600UL 96 36 0.36 82 P2 TWD 19 VS2

-0.82 TEN TEC 52 COLD 600UL 96 66 0.24 123 P2 TWD 14 VS4

+0.75 TEN TEC 57 COLD 600UL 96 78 0.32 46 P2 TWD 19 VS3

+0.13 TEN TEC 47 COLD 600UL 0.29 165 P2 TWD 18 DCT

+0.00 TEN TEC 47 COLD 600UL 96 92 0.17 162 P2 TWD 10 05C

+0.98 TEN TEC 48 COLD 600UL 96 108 0.32 45 P2 TWD 15 VS4

+1.08 TEN TEC 41 COLD 600UL 0.13 158 P2 TWD 7 04H

+0.85 TEN TEC 41 COLD 600UL 0.13 47 P2 TWD 7 03H

+0.91 TEN TEC 41 COLD 600UL 96 114 0.43 95 P2 TWD 19 VS3

-0.86 TEN TEC 41 COLD 600UL 96 120 0.33 147 P2 TWD 18 VS3

-0.92 TEN TEC 36 COLD 600UL 0.17 61 P2 TWD 11 VS3

+0.73 TEN TEC 36 COLD 600UL 0.21 60 P2 TWD 13 VS2

+0.94 TER TEC 36 COLD 600UL 97 27 0.24 90 P2 TWD 15 VS3

-0.93 TEH TEC 52 COLD 600UL 97 41 0.30 40 P2 TWD 16 VS3

-0.85 TEN TEC 55 COLD 600UL 0.27 139 P2 TWD 15 VS4

-0.85 TEN TEC 55 COLD 600UL 97 103 0.05 182 P2 TWD 3 DHB

+3.75 TEN TEC 39 COLD 600UL 97 109 0.25 43 P2 TWD 13 VS2

-0.93 TEN TEC 41 COLD 600UL 97 121 0.20 165 P2 TWD 13 VS2

-0.84 TEN TEC 36 COLD 600UL 98 28 0.18 101 P2 TWD 10 VS2

+0.99 TEN TEC 53 COLD 600UL 98 62 0.12 32 P2 TWD 8 VS2

-0.86 TEN TEC 57 COLD 600UL 98 84 0.20 151 P2 TWD 12 VS5

-0.89 TEN TEC 46 COLD 600UL 98 102 0.17 164 P2 TWD 10 VS4

-0.77 TEN TEC 38 COLD 600UL 99 107 0.20 99 P2 TWD 11 DHT

+0.00 TEN TEC 41 COLD 600UL 100 28 0.22 76 P2 TWD 14 02H

+0.83 TEN TEC 52 COLD 600UL 100 36 0.23 14 P2 TWD 14 08H

+0.57 TEN TEC 52 COLD 600UL 100 90 0.15 104 P2 TWD 12 06C

+0.06 TEN TEC 49 COLD 600UL 102 60 0.21 155 P2 TWD 13 VS4

-0.73 TEN TEC 57 COLD 600UL

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 67 of 92 Areva NP 6/7/2006 9:16 AM Component: S/G B Customer Name: St. Lucie Unit 2 Page 7 of 8 Tubes with Bobbin 1-19 TWD Indications ROW LINE VOLTS 102 92 0.16 102 122 0.24 103 75 0.17 103 137 0.24 104 30 0.26 104 134 0.29 105 33 0.23 106 62 0.15 107 31 0.29 0.29 107 51 0.25 107 77 0.33 107 89 0.11 108 32 0.23 108 34 0.27 108 90 0.11 109 89 0.18 110 92 0.14 ill 77 0.14 Ill 133 0.21 112 38 0.21 112 118 0.13 113 51 0.37 0.29 116 42 0.19 117 39 0.35 120 44 0.13 121 43 0.31 121 51 0.25 121 57 0.20 122 86 0.31 122 112 0.28 0.14 123 45 0.27 124 46 0.23 124 114 0.14 0.09 125 47 0.34 0.26 126 48 0.16 126 104 0.17 126 112 0.32 127 53 0.19 0.17 0.10 0.35 128 52 0.11 128 112 0.38 129 59 0.24 130 58 0.34 131 55 0.26 132 58 0.12 132 60 0.39 DEG 40 36 44 19 161 101 74 105 61 54 17 64 158 143 151 10 140ý 77 49 99 96 90 38 85 119 41 152 94 157 34 22 62 22 156 13 33 21 142 19 150 11 24 70 154 157 149 11 94 17 35 119 130 89 CHN IND P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD

%TW LOCATION EXT EXT 10 Vs4

-0.68 TEH TEC 14 VS1

-0.81 TEH TEC 10 VS2

+0.94 TEH TEC 16 VS2

+0.49 TEH TEC 16 VS3

-1.30 TEH TEC 17 VS1

+0.68 TEH TEC 14 02H

-0.15 TEH TEC 10 VS1

+0.13 TEH TEC 17 04C

-0.96 TEH TEC 17 02H

+0.89 TEH TEC 16 07C

+0.67 TEH TEC 19 04H

-0.56 TEH TEC 9

05H

+0.81 TEH TEC 14 02H

-0.90 TEH TEC 16 03C

-0.96 TEH TEC 9

02H

+0.91 TEH TEC 10 06C

+0.93 TEH TEC 9

07C

-0.11 TEH TEC 8

vS3

+0.85 TEH TEC 12 05C

+0.24 TEH TEC 13 VS4

-0.81 TEH TEC 14 VS1

+0.73 TEH TEC 19 02H

-0.13 TEH TEC 16 02H

+0.90 TEH TEC 11 05C

+0.89 TEH TEC 19 DCT

-0.17 TEH TEC 8

04H

+0.85 TEH TEC 17 DCT

+0.00 TEH TEC 14 05H

+0.96 TEH TEC 13 VS1

+0.86 TEH TEC 19 06H

+0.75 TEH TEC 15 VS4

-0.87 TEH TEC 9

05C

-0.15 TEH TEC 15 DHT

+0.00 TEH TEC 12 DCT

+0.00 TEH TEC 9

08H

+0.86 TEH TEC 6

08H

-0.80 TEH TEC 18 09C

+0.58 TEH TEC 15 DCT

+0.00 TEH TEC 8

07H

-0.99 TEH TEC 11 VS1

-1.04 TEH TEC 17 VS1

-0.90 TEH TEC 12 DCB

+0.00 TEH TEC 10 06H

-0.85 TEH TEC 7

06H

-0.17 TEH TEC 18 07H

+0.80 TEH TEC 8

DHT

+0.00 TEH TEC 18 DCT

-0.12 TEH TEC 13 DCT

+0.00 TEH TEC 16 DCT

+0.00 TEH TEC 16 05H

-0.98 TEH TEC 9

07H

+0.78 TEH TEC 18 DCT

+0.00 TEH TEC CAL 48 36 45 33 52 36 52 57 52 52 58 44 49 52 52 49 48 48 45 35 52 38 57 57 55 52 55 54 55 59 47 40 40 54 54 40 40 54 54 54 38 40 57 57 57 57 58 41 60 60 59 59 60

  1. LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600Ur 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL

St. Lucie Unit 2 Docket Ns. 50-3 89 L-2007-076 Attachment Page 68 of 92 Areva NP 6/7/2006 9:16 AM Component: S/G B Customer Name: St. Lucie Unit 2 Page 8 of 8 Tubes with Bobbin 1-19 TWD Indications ROW LINE VOLTS DEG CHN IND %TW LOCATION 132 80 0.28 33 P2 TWD 18 VS1

+0.78 132 110 0.33 128 P2 TWD 16 VS5

+0.80 133 61 0.19 104 P2 TWD 12 09H

+0.22 0.17 164 P2 TWD 11 09H

-1.13 133 87 0.17 141 P2 TWD 12 08H

+0.82 133 109 0.24 117 P2 TWD 12 08H

+0.75 0.27 123 P2 TWD 13 08H

-0.38 134 60 0.20 125 P2 TWD 13 DCT

+0.00 137 75 0.23 150 P2 TWD 16 05H

+0.88 137 99 0.24 150 P2 TWD 12 VS1

+0.95 EXT TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH EXT TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC CAL #

61 62 59 59 61 62 62 59 61 62 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL Total Tubes

316 Total Records: 381

St. Lucie Unit 2 L-2007-076 Docket Ns. 50-389 Attachment Page 69 of 92 Areva NP 6/7/2006 9:09 AM Customer Name: St.

Lucie Unit 2 Component: S/G A Page 1 of 14 Tubes with Bobbin 1-34% TWD Indications Left In Service ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 2

166 0.33 140 P2 TWD 22 01C

-0.83 07C TEC 20 COLD 600UL 3

49 0.39 60 P2 TWD 24 02C

-0.67 07H TEC 69 COLD 580SF 5

35 0.11 16 P2 TWD 7 04H

+0.95 TEH TEC 64 COLD 600UL 8

110 0.34 151 P2 TWD 13 06H

+0.96 TEH TEC 19 COLD 600UL 9

41 0.14 15 P2 TWD 10 04H

+0.90 TEH TEC 64 COLD 60OUL 14 166 0.20 63 P2 TWD 13 01C

-0.78 TEH TEC 22 COLD 600UL 15 165 0.17 151 P2 TWD 11 01H

-0.92 TEH TEC 22 COLD 600UL 16 4

0.09 28 P2 TWD 9 05H

-0.97 TEC TEH 86 HOT 600UL 19 63 0.45 110 P2 TWD 27 VS3

-0.69 TEH TEC 17 COLD 600UL 20 64 0.20 86 P2 TWD 17 VS3

-0.86 TEH TEC 18 COLD 600UL 20 166 0.18 137 P2 TWD 15 01H

+0.91 TEH TEC 30 COLD 600UL 21 127 0.16 41 P2 TWD 12 VS3

+0.82 TEH TEC 11 COLD 600UL 24 58 0.17 166 P2 TWD 13 VS3

-0.93 TEH TEC 15 COLD 600UL 24 60 0.24 29 P2 TWD 17 VS3

-0.73 TEH TEC 15 COLD 600UL 24 62 0.21 159 P2 TWD 17 VS3

+0.86 TEH TEC 18 COLD 600UL 24 64 0.09 147 P2 TWD 8 VS3

-0.73 TEH TEC 18 COLD 600UL 27 5

0.11 153 P2-TWD 12. 01H.

+0.81 TEC TEH-86 HOT-600UL,-

27 65 0.26 129 P2 TWD 19 DHB

+0.00 TEH TEC 17 COLD 600UL 27 165 0.26 144 P2 TWD 18 01C

-1.05 TEH TEC 31 COLD 600UL 29 163 0.15 158 P2 TWD 13 01C

-0.98 TEH TEC 30 COLD 600UL 29 165 0.20 143 P2 TWD 16 01H

-1.03 TEH TEC 30 COLD 600UL 0.22 144 P2 TWD 17 01C

-0.91 TEH TEC 30 COLD 600UL 30 164 0.12 172 P2 TWD 9 01H

-0.97 TEH TEC 31 COLD 600UL 31 67 0.45 120 P2 TWD 27 DCB

+0.00 TEH TEC 17 COLD 600UL 31 113 0.21 114 P2 TWD 15 VS3

-0.75 TEH TEC 5

COLD 600UL 32 106 0.13 154 P2 TWD 17 VS3

+0.79 TEH TEC 8

COLD 600UL 32 164 0.21 158 P2 TWD 17 01C

+0.86 TEH TEC 30 COLD 600UL 33 67 0.22 104 P2 TWD 18 DCB

+0.00 TEH TEC 18 COLD 600UL 33 111 0.25 69 P2 TWD 17 VS3

+0.85 TEH TEC 7

COLD 6COUL 34 68 0.48 119 P2 TWD 29 DHB

+0.00 TEH TEC 18 COLD 600UL 35 5

0.19 159 P2 TWD 17 01H

-1.00 TEC TEH 86 HOT 600UL 36 62 0.13 150 P2 TWD 12 VS3

-0.94 TEH TEC 18 COLD 600UL 36 164 0.11 170 P2 TWD 10 01H

+0.87 TEH TEC 30 COLD 600UL 37 27 0.13 61 P2 TWD 14 VS3

-0.77 TEC TEH 82 HOT 60OUL 37 67 0.13 81 P2 TWD 12 VS3

+0.73 TEH TEC 18 COLD 600UL 0.14 145 P2 TWD 13 DCB

+0.00 TEH TEC 18 COLD 600UL 37 99 0.39 101 P2 TWD 26 DCB

+0.00 TEH TEC 4

COLD 600UL 37 119 0.26 40 P2 TWD 13 VS3

+0.85 TEH TEC 9

COLD 600UL 37 121 0.16 150 P2 TWD 15 V53

+0.80 TEH TEC 10 COLD 600UL 38 66 0.16 159 P2 TWD 13 VS3

+0.71 TEH TEC 17 COLD 600UL 38 100 0.09 87 P2 TWD 8 VS3

+0.80 TEH TEC 7

COLD 600UL 38 124 0.34 94 P2 TWD 16 VS3

+0.82 TEH TEC 9

COLD 600UL 38 126 0.34 103 P2 TWD 16 VS3

+0.93 TEH TEC 9

COLD 600UL 38 162 0.20 149 P2 TWD 16 01H

+0.87 TEH TEC 30 COLD 600UL 39 51 0.40 148 P2 TWO 23 VS3

+0.73 TEH TEC 13 COLD 600UL 39 63 0.31 126 P2 TWD 22 VS3

-0.90 TEH TEC 17 COLD 600UL 39 71 0.55 115 P2 TWD 31 DCB

+0.00 TEH TEC 6

COLD 600UL 39 99 0.31 98 P2 TWD 19 DCB

+0.00 TEH TEC 3

COLD 600UL 39 109 0.07 158 P2 TWD 7 VS3

+0.80 TEH TEC 7

COLD 600UL 39 123 0.19 129 P2 TWD 10 VS3

+1.06 TEH TEC 9

COLD 600UL 40 40 0.18 166 P2 TWD 13 VS3

+0.59 TEH TEC 11 COLD 600UL 40 70 0.24 85 P2 TWD 18 DHB

+0.43 TEH TEC 43 COLD 600UL 0.22 113 P2 TWD 17 DCT

-0.25 TEH TEC 43 COLD 600UL

St. Lucie Unit 2 L-2007-076 Docket Ns. 50-389 Attachment Page 70 of 92 Areva NP 6/7/2006 9:09 AM Customer Name: St. Lucie Unit 2 Component: S/G A Page 2 of 14 Tubes with Bobbin 1-34% TWD Indications Left In Service ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 40 102 0.22 162 P2 TWD 23 VS3

-0.94 TEH TEC 8

COLD 600UL 41 15 0.11 63 P2 TWD 12 VS3

+0.90 TEC TEN 85 HOT 600UL 41 49 0.34 103 P2 TWD 21 VS3

-0.94 TEH TEC 13 COLD 600UL 41 61 0.12 51 P2 TWD 10 VS3

-0.83 TER TEC 17 COLD 600UL 41 71 0.29 151 P2 TWD 19 DCB

+0.57 TEH TEC 5

COLD 600UL 41 97 0.24 36 P2 TWD 19 DHB

+0.00 TEH TEC 4

COLD 600UL 0.20 28 P2 TWD 17 DCB

+0.00 TEN TEC 4

COLD 600UL 41 101 0.32 150 P2 TWD 20 DCT

+0.00 TEH TEC 7

COLD 600UL 41 115 0.18 155 P2 TWD 10 VS3

+0.88 TEN TEC 9

COLD 600UL 41 117 0.14 161 P2 TWD 13 VS3

+0.93 TEH TEC 10 COLD 600UL 41 125 0.26 62 P2 TWD 13 VS3

-0.72 TER TEC 9

COLD 60OUL 41 127 0.18 150 P2 TWD 17 VS3

-0.86 TEH TEC 10 COLD 60OUL 42 96 0.21 157 P2 TWD 18 VS3

-0.97 TEN TEC 4

COLD 600UL 0.56 80 P2 TWD 30 DHT

+0.00 TEN TEC 4

COLD 600UL 42 98 0.29 110 P2 TWD 22 DCB

+0.39 TEN TEC 4

COLD 600UL 42 108 0.06 8

P2 TWD 6 VS3

+0.11 TER TEC 7

COLD 600UL 42 124 0.33 140 P2 TWD 25 VS3

-0.85 TEH-TEC 10

-COLD 600UL 42 130 0.15 110 P2 TWD 10 VS3

-0.90 TEN TEC 21 COLD 600UL 42 134 0.09 69 P2 TWD 4 VS3

-0.81 TEN TEC 22 COLD 600UL 42 138 0.43 106 P2 TWD 26 05H

+0.85 TEN TEC 23 COLD 600UL 43 41 0.36 145 P2 TWD 19 VS3

+0.84 TEN TEC 12 COLD 600UL 43 59 0.30 146 P2 TWD 19 VS3

-0.90 TEN TEC 15 COLD 600UL 43 71 0.35 41 P2 TWD 25 DCB

+0.00 TEN TEC 6

COLD 600UL 43 93 0.33 156 P2 TWD 23 DHB

+0.00 TEN TEC 4

COLD 600UL 0.28 37 P2 TWD 21 VS3

+0.73 TEN TEC 4

COLD 600UL 0.50 132 P2 TWD 29 DCB

+0.00 TEN TEC 4

COLD 600UL 43 97 0.25 117 P2 TWD 19 DCT

+0.00 TEN TEC 3

COLD 600UL 0.31 139 P2 TWD 22 DCB

+0.00 TEN TEC 3

COLD 600UL 0.10 160 P2 TWD 10 VS3

+0.87 TEN TEC 3

COLD 600UL 43 99 0.29 41 P2 TWD 18 DHB

+0.00 TEN TEC 3

COLD 600UL 44 42 0.20 39 P2 TWD 11 VS3

+0.06 TEN TEC 12 COLD 600UL 0.22 123 P2 TWD 12 VS3

+0.67 TEN TEC 12 COLD 600UL 44 62 0.13 99 P2 TWD 11 VS3

+0.60 TEN TEC 17 COLD 600UL 44 70 0.41 113 P2 TWD 27 DCB

+0.00 TEN TEC 6

COLD 600UL 44 72 0.66 131 P2 TWD 29 DHB

+0.20 TEN TEC 5

COLD 600UL 44 94 0.49 111 P2 TWD 27 DHB

+0.00 TEH TEC 3

COLD 600UL 0.15 110 P2 TWD 13 DCB

+0.00 TEN TEC 3

COLD 600UL 44 124 0.13 150 P2 TWD 7 06C

+0.93 TEN TEC 9

COLD 600UL 44 126 0.36 142 P2 TWD 17 VS3

-0.74 TEN TEC 9

COLD 600UL 44 128 0.29 120 P2 TWD 14 VS3

+1.02 TEN TEC 9

COLD 600UL 44 156 0.36 113 P2 TWD 21 VS3

-0.94 TEN TEC 29 COLD 600UL 45 71 0.50 127 P2 TWD 26 DCB

+0.44 TEN TEC 5

COLD 600UL 45 75 0.22 125 P2 TWD 18 DHB

+0.00 TEN TEC 6

COLD 600UL 0.48 88 P2 TWD 29 DHT

+0.00 TEN TEC 6

COLD 600UL 0.42 128 P2 TWD 27 DCT

+0.00 TEN TEC 6

COLD 600UL 0.21 132 P2 TWD 18 DCB

+0.00 TEH TEC 6

COLD 6000L 45 91 0.75 157 P2 TWD 34 DHT

+0.00 TEN TEC 4

COLD 600UL 0.77 16 P2 TWD 34 DCT

+0.00 TEN TEC 4

COLD 600UL 0.62 96 P2 TWD 31 DHB

+0.00 TEN TEC 4

COLD 600UL 45 93 0.39 63 P2 TWD 24 DCB

+0.00 TEN TEC 3

COLD 600UL 0.13 157 P2 TWD 9 VS3

+0.98 TEN TEC 3

COLD 600UL 45 97 0.10 155 P2 TWD 10 VS3

+0.56 TEN TEC 4

COLD 600UL 0.29 97 P2 TWD 21 DCT

+0.00 TEN TEC 4

COLD 600UL

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 71 of 92 Areva NP 6/7/2006 9:09 AM Component: S/G A Attachment 9

Customer Name: St. Lucie Unit 2 Page 3 of 14 Tubes with Bobbin 1-34% TWD Indications Left In Service ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 0.18 45 99 0.32 45 111 0.23 45 129 0.19 45 133 0.19 46 52 0.29 46 72 0.15 46 74 0.39 46 76 0.68 0.66 0.50 46 90 0.34 0.42 0.22 46 100 0.41 0.17 46 112 0.26-46 138 0.18 46 146 0.10 47 31 0.08 47 65 0.25 47 75 0.18 47 91 0.45 47 93 0.28 47 97 0.56 0.44 47 105 0.20 0.21 47 115 0.58 0.36 47 125 0.18 47 155 0.27 48 50 0.49 0.13 48 72 0.25 0.23 48 74 0.40 48 76 0.57 0.41 48 78 0.15 0.35 0.50 0.19 48 90 0.37 0.36 0.08 48 94 0.11 48 96 0.41 0.32 48 98 0.10 48 100 0.29 48 102 0.25 48 108 0.17 29 P2 101 P2 70 P2 66 P2 107 P2 60 P2 106 P2 90 P2 94 P2 40 P2 114 P2 167 P2 134 P2 144 P2 61 P2 135 P2 36 P2.

160 P2 53 P2 172 P2 144 P2 113 P2 61 P2 114 P2 129 P2 111 P2 77 P2 14 P2 134 P2 89 P2 67 P2 154 P2 113 P2 16 P2 130 P2 137 P2 111 P2 119 P2 95 P2 154 P2 23 P2 132 P2 144 P2 115 P2 137 P2 12 P2 149 P2 124 P2 119 P2 28 P2 46 P2 68 P2 161 P2 TWD 16 TWD 23 TWD 16 TWD 10 TWD 12 TWD 18 TWD 14 TWD 26 TWD 34 TWD 33 TWD 30 TWD 23 TWD 26 TWD 18 TWD 30 TWD 20 TWDO18 TWD 15 TWD 11 TWD 9 TWD 19 TWD 14 TWD 26 TWD 17 TWD 29 TWD 26 TWD 15 TWD 16 TWD 22 TWD 17 TWD 10 TWD 20 TWD 25 TWD 10 TWD 17 TWD 16 TWD 23 TWD 27 TWD 23 TWD 12 TWD 21 TWD 25 TWD 14 TWD 24 TWD 23 TWD 8 TWD 10 TWD 25 TWD 22 TWD 10 TWD 19 TWD 24 TWD 19 DCB VS3 VS3 VS3 VS3 VS3 DCB DHB DHB DHT DCT DHT DCT DCB VS3 VS3 VS3.

VS3 VS3 DHT VS3 DHB DHB DHB VS3 DCB VS3 VS3 VS3 VS3 VS3 VS3 VS3 VS3 VS3 DCT DCT DHB DCB DHT DHB DCT DCB DCB DCT VS3 VS3 VS3 VS3 DHB DCB DCB VS3

+0.00

+0.60

+0.88

-0.69

+0.75

-0.99

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.70

-0.83

+0.68

-0.63

+0.58

+0.00

-0.78

+0.00

+0.00

+0.00

+0.85

+0.00

-0.85

+0.24

-0.81

+0.91

+0.91

-0.77

-0.70

+0.11

+0.61

+0.04

-0.24

+0.11

-0.17

-0.24

-0.09

-0.17

+0.00

+0.00

+0.00

-0.48

-0.80

-0.91

+0.71

+0.09

+0.00

+0.13

-0.83 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC.

TEH TEC TEH TEC TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL.

600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60DUL 60OUL 60OUL 600UL 600UL 600UL 600UL 600UL 60DUL 600UL 600UL 600UL 600UL 600UL 600UL 60DUL 60DUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL

St. Lucie Unit 2 Docket Ns. 50-389 Areva NP L-2007-076 Attachment Page 72 of 92 6/7/2006 9:09 AM Component: S/G A Customer Name: St. Lucie Unit 2 Paqe 4 of 14 Tubes with Bobbin 1-34% TWD Indications Left In Service ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 48 134 0.09 48 140 0.38 49 47 0.40 49 55 0.33 49 73 0.21 0.43 49 75 0.15 49 89 0.29 49 145 0.09 49 147 0.30 49 161 0.19 50 62 0.19 50 70 0.28 0.18 50 72 0.37 50 82 0.60 0.37 50 88 0.79 0.11 0.90 50 90 0.37 0.17 50 98 0.31 50 100 0.21 50 134 0.41 51 15 0.14 51 35 0.44 51 55 0.06 51 71 0.27 51 73 0.37 51 87 0.59 0.92 0.14 51 89 0.14 0.13 51 91 0.27 51 95 0.13 51 97 0.24 51 101 0.18 51 113 0.32 51 119 0.24 51 157 0.68 0.47 52 66 0.09 52 72 0.23 52 74 0.24 52 78 0.30 52 84 0.78 52 146 0.34 53 71 0.37 0.19 53 73 0.29 53 79 0.37 155 P2 123 P2 119 P2 141 P2 108 P2 128 P2 114 P2 124 P2 157 P2 93 P2 164 P2 145 P2 124 P2 78 P2 102 P2 73 P2 11 P2 71 P2 71 P2 79 P2 82 P2 146 P2 135 P2 153 P2 146 P2 115 P2 126 P2 19 P2 116 P2 67 P2 137 P2 53 P2 134 P2 50 P2 130 P2 95 P2 26 P2 159 P2 63 P2 127 P2 152 P2 93 P2 124 P2 160 P2 147 P2 99 P2 86 P2 106 P2 133 P2 145 P2 65 P2 63 P2 124 P2 TWO 6 TWD 22 TWD 23 TWD 20 TWD 18 TWO 27 TWD 14 TWD 22 TWD 12 TWD 18 TWD 14 TWD 16 TWD 22 TWD 16 TWD 25 TWD 28 TWD 22-TWD 32 TWO 10 TWD 34 TWD 25 TWD 15 TWD 22 TWD 22 TWD 23 TWD 14 TWD 28 TWD 8 TWD 21 TWD 22 TWD 29 TWO 34 TWD 13 TWD 13 TWD 12 TWD 21 TWD 12 TWD 15 TWD 14 TWD 20 TWD 20 TWD 30 TWD 25 TWD 9 TWD 16 TWD 17 TWD 19 TWD 30 TWO 20 TWD 22 TWD 14 TWO 22 TWD 25 06C VS3 VS3 VS3 DCT DCB DHB DCB VS3 DCB VS3 VS3 VS3 DCB DCB DCB DHB DHT DCT DCB DCB 05H VS3 VS3 DCT DHT VS3 07C DCT DCB DHB DCT DCB DCB DHB DHB DCB DHB VS3 VS3 VS3 VS3 VS3 VS3 DCT DCT DHB DCT VS3 DCT DCB DCB DCT

-0.56

+0.84

-0.98

-0.81

+0.00

+0.00

+0.00

+0.00

+1.01

+0.13

-0.99

-0.83

-0.70

+0.00

+0.00

+0.22

+2..00-

+0.00

+0.00

+0.00

+0.00

+0. 93

-0.98

-0.80

+0.06

+0.00

-0.91

-0.19

+0.00

+0.22

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.29

+0.73

+0.81

+0.81

-0.54

+0.93

-0.

92

-0.15

-0.24

+0.22

-0.23

+0.75

+0.00

+0.00

+0.00

+0.00 TEN TEC TEN TEC TEH TEC TEN TEC TEN TEC TEN TEC TEH TEC TEH TEC TEN TEC TEN TEC TER TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH. TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC TEN TEC TEN TEC TEC TEN TEC TEH TEH TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC TEN TEC TEN TEC TEH TEC TEN TEC TEH TEC 21 25 13 15 6

6 6

4 26 25 31 18 6

6 6

5 5-.

3 3

3 4

4 4

8 22 84 77 16 6

5 3

3 3

3 3

4 4

3 7

5 10 29 29 18 5

5 5

5 25 5

5 6

6 COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL.

600UL 600UL 600UL 600UL 60OUL 60OUL 600UL 600UL 600UL 60OUL 600UL 60OUL 600UL 60OUL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 60OUL 600UL 600UL

St. Lucie Unit 2 L-2007-076 Docket Ns. 50-389 Attachment Page 73 of 92 Areva NP 6/7/2006 9:09 AM Customer Name: St. Lucie Unit 2 Component: S/G A Page 5 of 14 Tubes with Bobbin 1-34% TWD Indications Left In Service ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 0.29 85 P2 TWD 22 DHT

+0.00 TEH TEC 6

COLD 600UL 53 81 0.93 68 P2 TWD 33 DCT

-0.04 TEH TEC 5

COLD 600UL 0.51 51 P2 TWD 26 DHB

-0.15 TEH TEC 5

COLD 600UL 0.31 126 P2 TWD 18 DHT

+0.00 TEH TEC 5

COLD 600UL 0.21 142 P2 TWD 15 VS3

-0.15 TEH TEC 5

COLD 600UL 53 107 0.31 71 P2 TWD 20 VS3

+0.71 TEH TEC 7

COLD 600UL 53 113 0.27 100 P2 TWD 18 VS3

+0.96 TEH TEC 5

COLD 600UL 53 117 0.15 147 P2 TWD 8 VS3

+1.00 TEH TEC 9

COLD 600UL 53 119 0.18 159 P2 TWD 10 VS3

+0.78 TEH TEC 9

COLD 600UL 53 123 0.24 53 P2 TWD 17 VS3

+0.79 TEH TEC 5

COLD 600UL 53 127 0.63 46 P2 TWD 23 VS3

-0.82 TEH TEC 9

COLD 600UL 53 129 0.24 159 P2 TWD 20 VS3

-0.92 TEH TEC 10 COLD 600UL 53 139 0.40 132 P2 TWD 25 VS3

-0.83 TEH TEC 23 COLD 600UL 0.24 41 P2 TWD 19 VS3

+0.62 TEH TEC 23 COLD 600UL 53 151 0.21 151 P2 TWD 17 VS3

-0.92 TEH TEC 28 COLD 600UL 54 72 0.17 161 P2 TWD 15 VS3

+0.75 TEH TEC 6

COLD 600UL 54 74 0.16 119 P2 TWD 15 VS3

-0.87.

TEH TEC.

6 COLD 600UL 0.31 153 P2 TWD 23 DCT

+0.00 TEH TEC 6

COLD 600UL 54 86 0.46 128 P2 TWD 28 VS3

-0.69 TEH TEC 4

COLD 600UL 0.27 89 P2 TWD 20 VS3

+0.84 TEH TEC 4

COLD 600UL 0.34 103 P2 TWD 24 DHB

+0.00 TEH TEC 4

COLD 600UL 0.21 134 P2 TWD 18 DCT

+0.00 TEH TEC 4

COLD 600UL 54 88 0.29 142 P2 TWD 21 DCB

+0.00 TEH TEC 3

COLD 600UL 54 90 0.22 106 P2 TWD 18 VS3

-0.98 TEH TEC 4

COLD 600UL 0.15 43 P2 TWD 14 DCB

+0.00 TEH TEC 4

COLD 600UL 54 96 0.33 113 P2 TWD 23 VS3

-0.94 TEH TEC 4

COLD 600UL 54 100 0.46 108 P2 TWD 31 VS3

+0.77 TEH TEC 8

COLD 600UL 0.15 94 P2 TWD 18 DHT

+0.00 TEH TEC 8

COLD 600UL 54 116 0.16 150 P2 TWD 15 VS3

-1.09 TEH TEC 10 COLD 600UL 54 126 0.11 148 P2 TWD 11 VS3

-0.86 TEH TEC 10 COLD 600UL 54 128 0.55 127 P2 TWD 22 VS3

-0.97 TEH TEC 9

COLD 600UL 55 9

0.19 21 P2 TWD 17 01H

-0.93 TEC TEH 87 HOT 600UL 55 73 0.27 137 P2 TWD 18 VS3

-0.11 TEH TEC 5

COLD 600UL 0.40 152 P2 TWD 23 DCB

+0.15 TEH TEC 5

COLD 600UL 55 87 0.37 143 P2 TWD 25 VS3

-0.80 TEH TEC 4

COLD 600UL 0.52 96 P2 TWD 29 DHB

+0.00 TEH TEC 4

COLD 600UL 0.42 80 P2 TWD 26 DCT

+0.00 TEH TEC 4

COLD 600UL 0.15 158 P2 TWD 14 DCB

+0.00 TEH TEC 4

COLD 600UL 55 93 0.19 145 P2 TWD 17 DCB

+0.00 TEH TEC 4

COLD 600UL 56 74 0.36 139 P2 TWD 22 VS3

+0.78 TEH TEC 5

COLD 600UL 56 78 0.22 112 P2 TWD 16 VS3

+0.04 TEH TEC 5

COLD 600UL 0.97 77 P2 TWD 33 DCB

+0.00 TEH TEC 5

COLD 60OUL 56 82 0.26 42 P2 TWD 18 DCT

-0.17 TEH TEC 5

COLD 600UL 0.20 150 P2 TWD 14 VS3

-0.83 TEH TEC 5

COLD 600UL 56 84 0.49 68 P2 TWD 25 DCB

-0.04 TEH TEC 5

COLD 600UL 56 88 0.36 151 P2 TWD 24 DCT

+0.00 TEH TEC 4

COLD 60OUL 56 90 0.17 74 P2 TWD 15 DHB

+0.00 TEH TEC 3

COLD 60OUL 56 92 0.57 29 P2 TWO 30 DHT

+0.00 TEH TEC 4

COLD 600UL 56 152 0.68 106 P2 TWD 32 VS3

-0.89 TEH TEC 28 COLD 600UL 57 67 0.10 162 P2 TWD 9 VS3

+0.85 TEH TEC 18 COLD 600UL 57 75 0.30 136 P2 TWD 23 VS3

-0.80 TEH TEC 6

COLD 600UL 57 77 0.74 121 P2 TWO 30 DCT

-0.02 TEH TEC 5

COLD 600UL 57 87 0.68 Ill P2 TWD 31 DCB

+0.00 TEH TEC 3

COLD 600UL

St. Lucie Unit 2 Docket Ns. 50-389 Areva NP L-2007-076 Attachment Page 74 of 92 6/7/2006 9:09 AM Component: S/G A Customer Name: St.

Lucie Unit 2 Page 6 of 14 Tubes with Bobbin 1-34% TIWD Indications Left In Service ROW LINE VOLTS 57 89 0.15 57 91 0.29 57 93 0.14 57 97 0.11 57 99 0.18 0.19 57 127 0.36 57 133 0.41 57 147 0.14 57 155 0.36 58 38 0.10 58 76 0.28 58 86 0.88 59 81 0.28 0.21 59 87 0.37

60. 78 0.27 0.17 60 82 0.13 0.76 60 86 0.26 61 25 0.43 61 51 0.11 61 81 0.23 61 83 0.16 61 85 0.34 62 74 0.16 62 86 0.25 0.42 62 118 0.24 63 41 0.28 0.08 63 79 0.19 64 44 0.07 64 68 0.21 64 72 0.24 64 98 0.26 66 142 0.12 72 20 0.33 72 24 0.16 73 77 0.25 0.16 74 16 0.12 75 41 0.10 75 43 0.26 0.24 75 49 0.28 0.49 75 73 0.37 75 85 0.18 76 84 0.16 76 116 0.18 0.20 DEG 150 113 170 147 145 34 72 102 34 125 157 115 127 115 139 101 90 114 55 96 101 103 66 124 140 96 58 135 148 141 134 62 85 161 109 145 62 156 120 146 136 147 26 52 123 99 108 120 135 90 152 106 144 CHN IND P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWDo P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD

%TW 14 21 10 11 13 13 17 23 10 21 8

22 33 22 18 25 18 13 10 30 20 29 12 16 12 23 15 19 25 12 16 11 14 8

16 17 17 9

25 17 20 15 13 8

18 16 18 26 22 15 15 10 11 LOCATION 04H

+0.93 DHB

+0.00 VS3

-0.69 vS3

+0.57 VS3

-0.74 VS3

+0.57 VS3

-0.26 VS3

+0.69 VS3

+0.79 VS3

+1.02 04H

+0.89 DCB

+0.00 DCB

+0.00 DCB

+0.00 DHB

+0.08 DHB

+0.00 VS3

+0.79 VS4

+0.00 DCB

+0.00 DHB

+0.08 DHB

+0.00 VS4

+1.12 VS2

-0.31 DCB

+0.00 DCB

+0.14 DCB

+0.00 VS4

-0.85 VS3

-0.74 DCB

+0.00 VS3

+0.99 VS2

+0.62 VS3

-0.68 DCB

+0.00 VS3

+0.96 VS3

+0.70 VS4

-0.92 VS4

-0.74 VS2

+0.87 VS2

-0.61 VS4

-0.85 VS2

-0.97 VS2

+0.55 VS2

+0.85 VS2

-1.04 VS2

+0.83 VS4

-1.03 VS2

-0.82 VS3

-0.68 VS3

+0.70 VS3

+0.78 VS3

+0.81 VS3

+0.83 08C

+0.89 EXT TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEN TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEH TEH TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH EXT TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC.

TEC TEC TEC TEC TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEC TEC TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC CAL #

4 3

3 3

3 3

9 22 25 29 11 6

3 6

6 4

5--

5 5

5 4

82 14 5

5 4

6 3

3 9

12 12 5

14 17 5

3 25 85 82 6

6 84 11 13 13 13 13 5

3 4

9 9

LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD..

COLD COLD COLD COLD NOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT COLD COLD HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 600UL 60OUL 600UL 600UL 6000L 600UL 600UL 600UL 600UL 6000L 600UL 600UL 600UL 600UL 600UL 6O0UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600DL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600DL 600UL 600UL 600UL 600UL 600UL

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 75 of 92 Areva NP 6/7/2006 9:09 AM Component: S/G A Customer Name: St. Lucie Unit 2 Page 7 of 14 Tubes with Bobbin 1-34% TWD Indications Left In Service ROW LINE VOLTS 77 51 0.13 77 85 0.27 77 117 0.29 78 52 0.18 0.76 78 56 0.33 0.19 78 62 0.62 0.34 0.37 78 100 0.17 78 110 0.12 78 148 0.11 79 63 0.15 0.25 0.15 79 67 0.54 0.38 79 77 0.26 79 127 0.30 80 68 0.15 80 128 0.31 81 29 0.78 0.67 0.60 0.49 0.16 81 139 0.24 81 143 0.12 0.25 82 70 0.15 82 72 0.18 82 74 0.54 82 94 0.24 0.19 82 106 0.25 82 112 0.33 0.46 0.22 83 57 0.20 83 73 0.23 83 89 0.27 0.23 0.23 0.32 84 52 0.17 0.82 0.30 84 70 0.15 84 114 0.32 84 120 0.19 0.25 85 21 0.11 DEG CHN IND 160 P2 TWD 145 P2 TWD 134 P2 TWD 139 P2 TWD 132 P2 TWO 97 P2 TWD 103 P2 TWD I11 P2 TWD 139 P2 TWD 92 P2 TWD 58 P2 TWO 164 P2 TWO 39 P2 TWD 132 P2 TWD 150 P2 TWD 20 P2 TWD 99 P2 TWD 121 P2 TWD 138 P2 TWD 136 P2 TWD 19 P2 TWO 122 P2 TWD 116 P2 TWD 120 P2 TWO 118 P2 TWD 58 P2 TWD 150 P2 TWD 160 P2 TWD 158 P2 TWD 124 P2 TWD 90 P2 TWO 156 P2 TWD 118 P2 TWD 154 P2 TWD 66 P2 TWD 151 P2 TWD 114 P2 TWD 148 P2 TWD 144 P2 TWO 165 P2 TWD 47 P2 TWD 146 P2 TWD 134 P2 TWD 154 P2 TWO 113 P2 TWD 162 P2 TWD 95 P2 TWD 126 P2 TWD 159 P2 TWD 84 P2 TWO 151 P2 TWD 139 P2 TWD 30 P2 TWD

%TW LOCATION 14 VS4

+0.79 20 VS4

+0.82 14 VS3

+1.00 13 VS4

-0.66 31 VS4

+0.83 20 VS3

+0.67 14 VS4

+0.91 30 VS2

+0.68 23 VS3

-0.96 24 VS4

+0.51 20 VS2

-0.07 11 06H

+0.98 13 05C

-0.19 12 VS2

+0.73 19 VS3

-0.99 12 VS4

+0.86 29 VS4"

+0.70 24 VS2

-0.83 18 VS2

-1.29 15 VS2

-0.90 13 VS4

+0.79 15 VS4

-0.99 32 VS3

+0.62 30 VS3

-0.15 29 VS4

-0.94 27 VS3

-0.97 13 VS4

+0.90 16 06C

+0.80 10 08C

+0.98 17 08C

-1.04 11 VS3

-0.78 13 VS3

-0.87 26 VS2

-1.02 19 VS2

+0.93 16 VS4

+0.80 17 VS3

+0.79 21 VS2

+0.00 25 VS4

+0.62 16 VS2

+0.66 14 VS2

+0.90 16 05H

+0.88 20 VS4

-0.76 18 VS3

-0.99 18 VS2

+0.69 22 VS3

+0.78 16 VS2

-0.88 34 VS3

+0.00 22 VS4

+0.58 14 07H

+0.84 21 VS4

-0.91 19 VS2

-0.81 23 VS4

-0.83 11 VS2

+0.20 EXT EXT TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC CAL #

14 4

9 15 15 15 15 17 17 17 8

8 26 17 17 17 17 17 5

9 17 9

54 54 54 54 54 32 32 32 44 44 44 46 46 39 37 37 37 50 44 46 46 46 46 51 51 51 45 37 35 35 55 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 60OUL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 60OUL 600UL 60OUL 600UL 60OUL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 76 of 92 Areva NP 6/7/2006 9:09 AM Component: S/G A Customer Name: St. Lucie Unit 2 Page 8 of 14 Tubes with Bobbin 1-34% TWD Indications Left In Service ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 39 0.15 53 0.36 83 0.34 0.12 141 0.33 0.20 147 0.17 20 0.18 24 0.15 94 0.15 118 0.41 142 0.11 0.16 21 0.16 0.63 97 0.16 101 0.18.

111 0.16 127 0.16 143 0.34 0.56 0.12 20 0.69 22 0.10 28 0.50 0.31 0.41 0.11 36 0.20 58 0.24 112 0.12 0.30 0.22 118 0.15 21 0.46 57 0.16 67 0.27 71 0.23 111 0.14 129 0.34 24 0.40 0.12 40 0.14 58 0.22 0.29 112 0.23 0.16 27 0.17 0.16 33 0.14 65 0.13 0.10 67 0.21 158 P2 66 P2 115 P2 117 P2 104 P2 129 P2 147 P2 60 P2 29 P2 166 P2 115 P2 155 P2 172 P2 157 P2 120 P2 18 P2 98 P2 162 P2 141 P2 30 P2 98 P2 20 P2 88 P2 157 P2 41 P2 79 P2 82 P2 86 P2 149 P2 51 P2 147 P2 153 P2 150 P2 153 P2 93 P2 16 P2 153 P2 129 P2 107 P2 88 P2 152 P2 124 P2 147 P2 159 P2 78 P2 154 P2 104 P2 21 P2 130 P2 151 P2 158 P2 102 P2 143 P2 TWO 15 TWD 25 TWO 23 TWO 12 TWO 20 TWD 14 TWO 16 TWD 14 TWO 12 TWO 14 TWD 26 TWO 9 TWO 12 TWO 13 TWO 30 TWO 12 TWDO 17 TWD 16 TWO 14 TWO 21 TWO 27 TWO 9 TWO 34 TWD 10 TWO 30 TWO 23 TWD 27 TWD 11 TWO 22 TWO 16 TWO 10 TWO 20 TWO 16 TWO 16 TWO 28 TWD 16 TWO 17 TWD 16 TWD II TWO 20 TWO 24 TWD 9 TWD 18 TWO 15 TWO 18 TWO 16 TWO 12 TWO 15 TWO 15 TWO 14 TWO 10 TWO 8 TWO 15 VS2 08H VS2 VS3 VS3 08H VS2 VS2 VS4 VS4 VS3 VS3 VS4 VS2 VS2 VS4 VS4 VS3 VS2 VS2 VS3 VS4 VS2 VS2 VS4 VS3 VS4 VS3 VS4 VS4 VS4 VS3 VS2 08H VS2 VS2 VS4 VS2 VS2 VS2 VS3 VS2 07H VS3 DHT VS2 VS4 VS4 VS2 VS4 VS4 VS4 VS2

-1.09

+0.60

-1 02

+0.00

+0.70

+0.86

+0.90

-0.89

-0.81

+0.76

-0.74

+1.00

-0.98

-0.89

+0.79

-0.59.81

-0.99

+0.45

-0.98

+0.38

+0.57

-0.97

+1.02

-0.30

-0.83

-0.77

+0.92

+0.49

-0.57

-1.04

-0.89

+0.74

+0.96

+0.66

+0.90

+0.88

+1.00

-0.85

+0.93

-0.82

-0.76

+0.72

-0.74

+0.00

-0.83

+0.74

-0.83

-0.57

+0.79

-0.79

-0.13

+0.63 TEN TEC TEN TEC TEW TEC TEN TEC TEH TEC TEN TEC TEN TEC TEH TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEW TEC TEN TEC TEH TEC TER TEC TEN TEC TEH TEC TEH TEC TEN TEC TEH TEC TEW TEC TEH TEC TEH TEC TEN TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEN TEC TEN TEC TEH TEC TEN TEC TEN TEC TEH TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC TEN TEC TEN TEC TEH TEC TEW TEC COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD.

COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD 60OUL 60OUL 600UL 60OUL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 60OUL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 60OUL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 6000L 600UL 600UL 600OL 600UL 600UL 600UL

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 77 of 92 Areva NP 6/7/2006 9:09 AM Component: S/G A Customer Name: St. Lucie Unit 2 Page 9 of 14 Tubes with Bobbin 1-34% TWD Indications Left In Service ROW LINE VOLTS 91 101 0.09 91 103 0.12 0.31 91 127 0.17 91 129 0.27 91 133 0.22 92 26 0.41 0.51 0.23 0.24 0.37 92 32 0.20 92 90 0.20 92 102 0.23 92 112 0.13 92 116 0.24 0.13 92 132 0.29 93 35 0.15 93 75 0.32 93 77 0.35 93 87 0.23 0.45 0.37 93 117 0.13 93 131 0.19 0.81 94 34 0.18 0.07 94 44 0.18 0.23 0.43 94 64 0.40 0.83 0.42 0.16 0.35 94 72 0.19 0.19 94 76 0.26 94 88 0.46 0.14 0.50 94 96 0.87 0.20 0.60 94 106 0.17 94 116 0.32 94 120 0.75 0.33 0.34 94 126 0.26 94 144 0.13 DEG 171 151 128 154 133 155 47 128 93 108 86 153 146 42 145 146 19 55 17 157 112 150 127 34 139 61 46 158 18 151 152 51 143 69 153 168 25 141 155 25 147 235 130 113 108 84 138 45 100 138 82 78 150 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 INO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWO TWD TWO TWD TWD TWD TWD TWD TWO TWD TWD TWD TWD TWD

%TW 10 13 24 18 18 15 27 30 19 20 25 18 16 20 11 21 13 22 14 24 21 18 27 24 14 14 31 17 9

16 19 26 22 33 23 11 20 14 14 17 27 13 28 33 13 28 13 20 32 24 24 21 12 LOCATION 08C

+0.98 VS2

-0.98 VS4

-0.98 VS2

-0.74 VS2

-0.78 08C

+0.99 VS4

-0.85 VS4

+0.58 VS3

-0.85 VS2

+0.77 05C

-0.89 VS2

-0.97 VS2

+0.83 VS2

+0.76 VS3

-0.89 VS2

-0.79 08C

+1.10 VS2

+0.72 05H

-0.92 VS2

-0.88 DCB

+0.74 VS4

+0.92 VS2

+0.87 VS2

-0.90 VS3

+0.68 VS2

-0.98 VS2

+0.78 VS2

-0.83 VS2

+0.36 DCT

+0.00 VS2

-0.85 VS2

+0.79 VS2

-0.93 VS2

+0.72 VS3

+0.85 VS4

-0.63 VS4

+0.06 VS2

+0.97 VS4

+0.87 VS3

-0.40 VS4

+0.65 VS3

-0.97 VS2

-0.93 VS2

-0.98 VS3

-0.40 VS4

+0.93 VS2

+0.91 VS4

-0.85 VS2

+0.62 VS3

-0.88 VS4

-0.90 VS2

-0.91 01C

+0.93 EXT EXT TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC-TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC CAL #

41 41 41 35 32 32 55 55 55 55 55 53 47 41 37 38 38 33 52 45 44 47 47 47 38 32 32 53 53 52 52 52 48 48 48 48 48 44 44 44 46 46 46 48 48 48 39 37 36 36 36 36 33 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD

'COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600uL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600OL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 78 of 92 Areva NP 6/7/2006 9:09 AM Component: S/G A Customer Name: St. Lucie Unit 2 Page 10 of 14 Tubes with Bobbin 1-34% TWD Indications Left In Service ROW LINE VOLTS 95 31 0.10 95 41 0.79 95 57 0.35 0.27 95 59 0.44 0.51 0.14 95 71 0.27 95 89 0.44 0.26 0.40 95 105 0.60 95 127 0.18 95 135 0.28 0.24 95 139 0.19 95 143 0.21 96 30 0.44 0.29 0.23 0.30 0.12 0.10 0.21 96 34 0.37 96 58 0.16 0.14 0.31 96 60 0.25 96 62 0.19 96 78 0.59 96 108 0.65 0.91 0.49 0.38 0.08 96 128 0.13 0.09 96 134 0.25 0.38 96 138 0.28 0.57 96 142 0.14 97 31 0.19 97 87 0.20 0.36 97 93 0.25 0.74 0.18 0.22 97 121 0.51 97 127 0.49 0.16 DEG 46 12 91 94 137 84 115 36 123 97 97 102 145 128 27 134 129 5

153 42 125 166 129 119 144 162 125 60 13 90 71 104 91 151 141 166 157 31 120 63 137 102 165 165 158 129 116 125 55 113 101 59 78 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2

-P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW 8

33 25 21 23 25 10 17 26 20 25 32 18 18 16 17 15 28 22 19 23 12 10 18 25 15 14 23 17 14 28 28 32 25 22 7

13 9

17 22 18 27 14 17 16 24 19 32 16 18 28 26 13 LOCATION EXT EXT VS2

+0.86 TEN TEC DHT

+0.00 TER TEC VS2

+0.75 TER TEC DHT

+0.00 TEN TEC VS2

+0.87 TEE TEC VS3

+0.57 TEE TEC VS3

-0.87 TEN TEC VS2

+0.83 TEH TEC VS4

-0.84 TEE TEC VS2

-1.07 TEE TEC VS2

+0.50 TEN TEC VS3

+0.72 TEN TEC VS2

-0.85 TEN TEC VS2

-0.94 TEN TEC VS2

+0.36 TEN TEC VS2

-1.01 TEN TEC VS2

-0.92 TEH-TEC'-

DCT

+0.00 TEN TEC VS3

+0.85 TEN TEC VS2

-0.85 TEH TEC VS2

+0.83 TEN TEC VS3

-0.75 TEN TEC VS3

-0.09 TEN TEC VS4

+0.83 TEN TEC VS2

-0.77 TEE TEC VS3

+0.87 TEE TEC VS3

-0.65 TEN TEC VS4

-0.06 TEH TEC DHB

+3.75 TEE TEC VS3

-0.72 TEH TEC VS3

-1.07 TEN TEC VS2

-0.74 TEN TEC VS3

-0.70 TEN TEC VS4

+0.68 TEN TEC VS2

+0.76 TEE TEC VS3

+0.88 TEH TEC VS2

-0.92 TEN TEC VS4

-0.80 TEE TEC VS2

+0.89 TEH TEC VS3

-0.87 TEE TEC VS2

+0.91 TER TEC VS3

-0.60 TEN TEC VS4

-0.98 TEE TEC VS2

+1.03 TEE TEC VS3

+0.79 TEE TEC VS2

-0.78 TEN TEC VS4

+0.61 TEE TEC VS3

+0.83 TEH TEC VS2

+0.19 TEE TEC VS2

-0.78 TEN TEC 08C

+0.88 TEE TEC VS3

+0.64 TEE TEC VS4

+0.68 TEE TEC CAL #

54 52 51 51 50 50 50 44 46 46 46 41 35 32 32 33 32 55 55 55 55 55 55 55 52 51 51 51 49 49 44 39 39 39 39 39 33 33 32 32 32 32 33 55 47 47 46 46 46 46 36 34 34 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600OL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600OL 600UL 600UL 600UL 600UL 600OL 600UL 600OL 600UL 600UL 600UL 600UL 60CUL 600UL 600UL 600UL

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 79 of 92 Areva NP 6/7/2006 9:09 AM Component: S/G A Page 1i of 14 Customer Name: St. Lucie Unit 2 Tubes with Bobbin 1-34% TWD Indications Left In Service ROW LINE VOLTS 0.22 97 133 0.47 0.25 97 137 0.18 97 139 0.46 97 141 0.20 98 26 0.23 98 28 0.63 0.15 98 30 0.42 0.18 98 90 0.13 99 27 0.13 100 108 0.13 101 27 0.21 101 109 0.25 101 111 0.17 0.13 0.17 101 139 0.03 102 44 0.37 102 120 0.30 102 140 0.18 103 37 0.35 104 138 0.13 105 33 0.47 108 32 0.21 111 35 0.31 111 87 0.13 112 76 0.29 113 131 0.20 115 101 0.07 116 42 0.23 0.32 116 78 0.11 117 43 0.13 117 55 0.15 119 41 0.27 119 105 0.17 121 49 0.23 121 111 0.29 122 44 0.55 0.12 123 47 0.17 123 49 0.12 123 55 0.19 123 57 0.14 123 113 0.34 0.36 0.42 0.11 123 119 0.14 124 46 0.29 DEG 129 90 117 135 72 128 147 104 136 50 166 34 144 42 69 30 74 168 62 18 50 143 32 20 14 97 32 55 147 146 80 20 105 58 114 154 25 73 167 46 139 113 110 121 157 147 152 36 137 132 57 114 65 CHN IND %TW LOCATION P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 22 P2 P2 P2 P2 P2 P2 P2 TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD 17 28 20 13 24 14 19 30 12 24 14 12 10 10 18 16 13 10 13 3

25 23 16 24 13 28 18 22 11 18 14 8

13 17 11 12 11 21 13 15 20 29 12 12 13 17 14 21 22 24 9

14 22 Vs2 VS2 VS4 01C VS2 07C 08H VS4 VS2 VS2 VS3 DCT VS1 DCT 02H VS3

.08C 08C 07C VS2 DCB VS3 09H DCB 08H VS2 VS2 07H VS2 VS2 07H 05H VS1 VS1 VS1 VS4 VS1 VS1 03H DCT 08C DCT DCB VS2 VS1 VS1 VS1 VS1 VS3 VS4 VS5 VS4 DCT

-0=.72

-0.74

-0.78

+0.13

-0.96

-0.13

-1.04

+0.60

+0.92

+0.51

+0.81

-0.17

-0.48

+0.00

-0.06

+0.76

-0.94

+0.94

-1.03

-1.02

+0.00

-0.77

-1.01

+0.00

+0.84

+0.21

+0.89

-0.99

-1.01

-0.66

-1.02

+0.85

-0.99

+0.99

-0.80

+0.93

+0.80

-0.64

+0.89

-0.06

-0.79

+0.00

+0.00

+0.63

+0.84

-0.99

+0.66

-0.7O

+0.74

+0.79

+0.89

-0.96

+0.00 EXT EXT TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEB TEC-TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC CAL #

34 33 33 32 32 32 55 54 54 54 54 47 54 39 55 40 37 37 37 32 52 36 33 52 33 52 52 52 47 44 32 41 52 52 45 52 50 52 39 50 58 52 52 50 51 51 51 37 37 37 37 36 52 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 600UL 600OL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 60DUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 60OUL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600OL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 60OUL

St. Lucie Unit 2 Docket Ns. 50-3 89 L-2007-076 Attachment Page 80 of 92 Areva NP 6/7/2006 9:09 AM Component: S/G A Customer Name: St. Lucie Unit 2 Page 12 of 14 Tubes with Bobbin 1-34% TWD Indications Left In Service ROW LINE VOLTS 124 50 0.22 0.34 0.57 0.08 124 54 0.16 124 66 0.16 125 47 0.18 125 49 0.15 125 51 0.17 125 57 0.09 125 59 0.15 0.25 125 79 0.13 125 99 0.12 125 101 0.07 125 105 0.11 125 10.7 0.28 125 115 0.17 125 121 0.14 0.44 126 50 0.44 0.46 0.20 0.17 0.11 126 54 0.42 0.35 126 60 0.21 126 72 0.50 0.24 126 74 0.12 126 86 0.11 126 96 0.17 0.20 126 104 0.17 126 106 0.34 126 120 0.22 127 51 0.17 0.14 127 57 0.18 127 59 0.23 0.35 0.09 127 107 0.21 127 115 0.15 127 117 0.21 128 52 0.41 128 54 0.24 128 60 0.07 0.25 128 64 0.49 128 116 0.21 129 55 0.25 DEG CHN 52 P2 104 P2 129 P2 11 P2 34 P2 147 P2 42 P2 137 P2 91 P2 131 P2 23 P2 14 P2 77 P2 15 P2 44 P2 143 P2 110 P2 167 P2 163 P2 42 P2 108 P2 109 P2 74 P2 143 P2 18 P2 151 P2 109 P2 54 P2 123 P2 35 P2 134 P2 150 P2 84 P2 132 P2 142 P2 106 P2 12 P2 131 P2 46 P2 80 P2 71 P2 124 P2 45 P2 46 P2 144 P2 125 P2 44 P2 106 P2 172 P2 137 P2 131 P2 116 P2 129 P2 IND %TW TWO 19 TWD 24 TWD 30 TWD 9 TWD 15 TWD 11 TWD 17 TWD 11 TWD 16 TWD 7 TWD 11 TWD 16 TWD 13 TWD 9 TWD 8 TWD 12 TWO 18 TWD 14 TWD 16 TWD 29 TWD 23 TWD 24 TWD 14 TWD 12 TWD 9 TWD 22 TWD 20 TWD 14 TWD 25 TWD 16 TWD 12 TWD 11 TWD 12 TWD 13 TWD 17 TWO 21 TWD 21 TWD 12 TWD 10 TWD 16 TWD 19 TWD 25 TWO 10 TWD 16 TWD 12 TWD 20 TWD 22 TWD 20 TWD 8 TWD 14 TWD 25 TWD 16 TWD 16 LOCATION DHT

+0.00 VS1

+0.69 VS2

-0.82 VS2

+0.60 DCT

-0.25 VS1

+0.81 DCT

+0.00 VS1

+0.89 DHT

+0.00 DCT

+0.00 VS1

+0.71 DCT

+0.00 VS1

-0.71 09C

-0.74 VS5

-0.66 08C

+0.62 VS1..

+0.84 VS1

+0.94 07H

+0.86 DCT

+0.00 08H

-0.23 VS1

+0.78 05H

-0.30 03H

+0.88 07H

-0.28 VS1

+0.82 VS1

-0.07 08H

+0.73 08H

+0.89 09H

+0.13 VS2

+0.81 09H

-0.97 07C

+0.00 08H

-0.94 VS2

+0.90 VS1

-0.89 08H

-0.91 04H

-0.77 09H

+0.88 VS1

+0.63 VS1

-0.24 VS1

+0.84 DCT

+0.00 DCT

+0.00 VS1

-0.96 VS1

+0.73 DHT

-0.09 DHT

+0.00 VS5

-0.65 DHB

+0.11 VS1

+0.68 VS2

+0.94 DCB

+0.00 EXT TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH EXT TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC-TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC CAL #

51 51 51 51 51 48 51 50 51 50 50 50 45 49 41 41 39 58 35 35 50 50 50 50 50 50 50 50 44 44 45 46 48 48 41 39 35 50 50 51 51 51 51 58 37 35 50 51 51 51 48 58 50 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 600UL 600UL 600UL 600OL 600UL 60OUL 600UL 6000L 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL" 600UL 60OUL 600UL 600UL 600UL 60OUL 600OL 600UL 600UL 600UL 600UL 600OUL 600UL 600UL 60OUL 600UL 600UL 600OUL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 81 of 92 Areva NP 6/7/2006 9:09 AM Component: S/G A Customer Name: St. Lucie Unit 2 Page 13 of 14 Tubes with Bobbin 1-34% TWD Indications Left In Service ROW LINE VOLTS 129 57 0.77 129 61 0.54 129 63 0.23 129 103 0.35 129 109 0.31 130 58 0.30 130 60 0.40 130 64 0.25 131 79 0.18 132 58 0.37 0.26 132 64 0.57 0.13 0.13 132 68 0.19 132 92 0.36 132 102 0.20-.

132 108 0.36 132 110 0.12 133 61 0.46 0.30 0.32 0.23 133 67 0.20 133 73 0.18 133 75 0.25 133 77 0.13 133 109 0.19 0.23 0.16 134 62 0.15 0.17 0.15 0.11 0.15 134 72 0.32 0.12 134 76 0.10 134 98 0.39 134 100 0.10 134 102 0.71 134 104 0.16 135 63 0.45 0.59 0.31 0.28 0.48 135 71 0.24 135 73 0.67 0.25 0.51 1.13 0.17 DEG CHN IND 91 P2 TWD 19 P2 TWD 24 P2 TWD 26 P2 TWD 142 P2 TWD 88 P2 TWD 151 P2 TWD 147 P2 TWD 136 P2 TWD 74 P2 TWD 149 P2 TWD 80 P2 TWD 84 P2 TWD 170 P2 TWD 141 P2 TWO 158 P2 TWD 126.P2 TWD 46 P2 TWD 157 P2 TWD 56 P2 TWD 138 P2 TWO 67 P2 TWD 12 P2 TWD 39 P2 TWD 112 P2 TWD 113 P2 TWD 166 P2 TWO 85 P2 TWD 145 P2 TWO 95 P2 TWD 150 P2 TWO 120 P2 TWD 82 P2 TWD 22 P2 TWD 136 P2 TWD 105 P2 TWD 132 P2 TWD 154 P2 TWD 72 P2 TWD 154 P2 TWD 138 P2 TWD 21 P2 TWD 91 P2 TWD 45 P2 TWD 64 P2 TWD 63 P2 TWD 120 P2 TWD 49 P2 TWD 81 P2 TWD 122 P2 TWD 48 P2 TWD 130 P2 TWD 47 P2 TWD

%TW 30 26 16 25 21 18 22 17 14 29 25 27 11 10 14 21 15.

21 16 20 15 15 15 15 20 24 17 21 23 9

18 20 18 15 18 27 9

9 30 8

29 13 31 34 27 26 10 17 28 17 25 34 13 LOCATION OCT

+0.00 OUT

+0.00 VS1

+0.71 VS5

-0.90 VS1

-1.02 DCB

+0.19 DHT

+0.00 VS1

+0.62 VS4

-0.86 DHB

+0.01 DCB

+0.00 DHT

+0.00 07H

+0.61 DHB

+0.00 VS2

-1.00 VS1

+0.98 OCT

+0.00.

DCB

+0.00 VS5

-0.99 08H

-1.00 DHB

+0.00 DHT

+0.00 DCT

-0.17 VS1

+0.68 VS1

-0.75 VS1

+0.68 VS5

+0.77 07C

-1.00 DHT

+0.24 DHB

+0.00 07H

+0.88 08H

-0.99 DHT

-0.04 DCT

+0.11 VS3

+0.95 VS1

+0.81 VS5

+1.05 VS5

-1.01 VS3

-0.34 VS4

-0.76 DCT

+0.00 05H

+0.70 09H

+0.93 VS1

-0.69 VS1

+0.83 DHB

+0.00 DHT

+0.00 VS1

-0.91 VS1

+0.79 VS2

+0.67 VS3

+0.69 VS4

+0.79 VS5

+0.88 EXT EXT TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC.

TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC CAL # LEG 50 COLD 50 COLD 49 COLD 41 COLD 58 COLD 50 COLD 50 COLD 49 COLD 56 COLD 57 COLD 57 COLD 56 COLD 56 COLD 56 COLD 56 COLD 56 COLD 56 COLD_

56 COLD 57 COLD 57 COLD 57 COLD 57 COLD 57 COLD 56 COLD 57 COLD 57 COLD 57 COLD 57 COLD 57 COLD 57 COLD 57 COLD 57 COLD 57 COLD 57 COLD 57 COLD 57 COLD 57 COLD 56 COLD 57 COLD 56 COLD 56 COLD 56 COLD 57 COLD 57 COLD 57 COLD 57 COLD 57 COLD 56 COLD 56 COLD 56 COLD 56 COLD 56 COLD 56 COLD PROBE 600UL 600UL 600UL 600UL 60OUL 600UL 60OUL 600UL 600UL 600UL 600UL 60OUL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 60OUL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 60OUL 600UL 600UL 60OUL 60OUL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 60OUL 600UL 60OUL 600UL 600UL 600UL 600UL 60OUL

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 82 of 92 Areva NP 6/7/2006 9:09 AM Component: S/G A Customer Name: St. Lucie Unit 2 Paqe 14 of 14 Tubes with Bobbin 1-34% TWD Indications Left In Service ROW LINE VOLTS 0.26 135 83 0.21 135 95 0.34 135 97 0.78 0.87 0.15 135 99 0.14 0.12 136 70 0.56 0.30 0.44 0.10 136 76 0.27 136 98 0.11 136 102 0.16 137 69 0.12 137 97 0.11 137 99 0.30 137 101 0.48 0.23 DEG 40 134 153 60 78 26 81 102 128 94 112 166 109 171 17 152 142 47 35 138 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW 18 22 20 30 31 12 11 10 33 26 31 13 18 9

19 15 14.

27 32 23 LOCATION VS1

-0.76 VS1

-0.81 VS1

-0.94 VS1

-0.81 Vs3

+0.94 Vs5

+0.17 VS5

-0.81 DCB

+0.32 VS1

-0.84 VS2

+0.92 VS3

-0.73 VS5

-0.94 DCT

-0.09 VS1

-0.83 VS1

-0.95 07H

+0.70 DCB-.-...

+0.36 VS5

-0.83 09H

+0.93 DHT

+0.23 EXT TEN TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH EXT TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC.

TEC TEC TEC CAL #

56 57 56 56 56 56 56 56 57 57 57 57 56 56 57 57 57--

57 57 57 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 600UL 60OUL 600UL 600UL 600UL 60OUL 60OUL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 60OUL 60OUL Total Tubes

493 Total Records: 709

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 83 of 92 Areva NP 6/7/2006 9:18 AM Component: S/G B 0 Customer Name: St. Lucie Unit 2 Page 1 of 10 Tubes with Bobbin 1-34 TWO Indications Left In Service ROW LINE VOLTS 1

3 0.12 1

131 0.12 2

126 0.20 5

121 0.15 6

4 0.28 12 166 0.39 15 133 0.16 19 117 0.24 20 104 0.25 22 64 0.11 24 62 0.14 24 104 0.32 24 106 0.32 25 65 0.21 25 113 0.25 26 104 0.31 27 103 0.23 27 163 0.52 28 56 0.11 28 104 0.23 28 106 0.28 29 45 0.30 29 107 0.21 30 102 0.26 31 5

0.22 31 103 0.30 32 4

0.17 32 106 0.47 32 118 0.22 33 99 0.40 33 101 0.43 33 151 0.18 34 4

0.20 34 98 0.78 0.56 0.58 0.53 0.64 0.69 34 102 0.16 0.43 34 104 0.32 34 108 0.51 34 112 0.27 35 69 0.24 35 71 0.81 0.63 35 97 0.66 35 101 0.54 35 103 0.22 35 111 0.20 35 137 0.33 0.41 35 163 0.22 DEG CNN IND %TW LOCATION EXT EXT CAL # LEG 17 P2 12 P2 158 P2 155 P2 125 P2 77 P2 72 P2 164 P2 95 P2 147 P2 38 P2 131 P2 135 P2 44 P2 141 P2 135 P2 159 P2 51 P2 11 P2 103 P2 37 P2 27 P2 32 P2 126 P2 152 P2 122 P2 153 P2 74 P2 139 P2 38 P2 115 P2 40 P2 98 P2 30 P2 169 P2 119 P2 112 P2 37 P2 67 P2 49 P2 67 P2 29 P2 60 P2 151 P2 141 P2 42 P2 132 P2 52 P2 56 P2 46 P2 159 P2 125 P2 35 P2 20 P2 TWD 7 TWD 13 TWD 12 TWD 11 TWD 19 TWD 20 TWD 11 TWD 14 TWD 14 TWD 9 TWD 10 TWD 17 TWD 17 TWO 14 TWD 14 TWD 19 TWD 15 TWD" 24 TWD 7 TWD 13 TWD 15 TWD 18 TWD 15 TWD 17 TWO 16 TWO 19 TWD 13 TWD 22 TWD 13 TWD 18 TWD 20 TWD 12 TWD 11 TWD 29 TWD 24 TWD 25 TWD 24 TWD 26 TWD 27 TWO 11 TWD 24 TWD 20 TWO 26 TWD 18 TWO 11 TWD 28 TWO 24 TWD 26 TWO 27 TWD 15 TWO 12 TWD 20 TWO 22 TWO 14 01C 04H 05C 04C 07C CiC 04H VS3 VS3 VS3 VS3 VS3 VS3 VS3 VS3 VS3 VS3 VS3 VS3 VS3 VS3 VS3 VS3 VS3 o1C VS3 02H VS3 VS3 DCB DCT VS3 02H DHB DHT VS3 VS3 DCT DCB VS3 VS3 V53 VS3 VS3 DCT DHT DCB DHB VS3 VS3 VS3 DHB VS3 01H

-0.97

+0.86

+0.96

+0.88

+0.22

-0.98

+0.87

+0.81

+0.72

+0.86

+0.95

+0.72

+0.87

+0.85

-0.81

+0.79

-0.98

+0.70

-0.94

+0.82

+0.76

-0.54

+0.68

+0.85

-0.87

-0.78

+0.92

-1.06

+0.07

+0.00

+0.00

+0.88

-0.66

+0.00

-0.25

-0.82

+0.82

-0.11

+0.09

-0.94

+0.70

-0. 96

-0.80

-0.80

+0.00

+0.00

+0.00

+0.00

-1.11

-0.80

-0.76

+0.97

-0.96

+0.79 07C TEC 07H TEN 07C TEC TEN TEC TER TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TER TEC TEN TEC TEN TEC TEN TEC TER TEC TEN TEC TEN TEC' TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEC TEN TEN TEC TEC TEN TEN TEC TEN TEC TEH TEC TEN TEC TEN TEC TEC TEN TEN TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TER TEC TEN TEC TEN TEC TEN TEC TEN TEC 68 92 12 9

65 8

6 30 34 17 17 34 32 16 29 33 33 8

18 34 32 19 31 33 97 33 97 32 29 50 34 6

98 51 51 51 51 51 51 33 33 33 31 31 14 14 14 51 33 33 32 5

5 8

COLD HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT COLD HOT COLD COLD COLD COLD COLD HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUE 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL

St. Lucie Unit 2 Docket Ns. 50-3 89 L-2007-076 Attachment Page 84 of 92 Areva NP 6/7/2006 9:18 AM Component: S/G B 0 Customer Name: St. Lucie Unit 2 Page 2 of 10 Tubes with Bobbin 1-34 TWD Indications Left In Service ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 68 70 126 162 164 5

71 99 101 68 104 15.

23 65 69 95 133 141 104 162 69 30 94 106 136 162 33 47 61 75 26 76 92 94 142 71 75 97 22 44 66 68 0.49 0.33 0.77 0.39 0.20 0.25 0.26 0.41 0.76 0.59 1.02 0.58 0.73 0.19 0.30 0.26 0.12 0.20 0.44 0.21 0.26 0.58 0.34 0.20 0.12 0.26 0.73 0.35 0.35 0.26 1.08 0.14 0.23 0.35 0.16 0.51 0.74 0.48 0.29 1.08 0.65 0.65 0.75 0.44 0.35 0.35 0.74 0.31 0.40 0.25 0.27 0.24 0.21 0.30 52 P2 18 P2 117 P2 140 P2 150 P2 73 P2 78 P2 99 P2 37 P2 51 P2 124 P2 64 P2 47 P2 142 P2 158 P2 34 P2 17.6 P2 138 P2 35 P2 12 P2 132 P2 107 P2 88 P2 15 P2 50 P2 16 P2 154 P2 94 P2 139 P2 152 P2 104 P2 63 P2 26 P2 104 P2 150 P2 119 P2 48 P2

37. P2 146 P2 99 P2 59 P2 40 P2 9

P2 33 P2 105 P2 143 P2 128 P2 112 P2 146 P2 133 P2 21 P2 52 P2 134 P2 100 P2 TWD 24 TWD 19 TWD 31 TWD 22 TWD 12 TWD 15 TWD 17 TWD 19 TWD 31 TWD 25 TWD 32 TWD 25 TWD 28 TWD 11 TWD 17 TWD 17 TWD 8-_

TWD 12 TWD 22 TWD 10 TWD 12 TWD 23 TWD 15 TWD 13 TWD 9 TWD 17 TWD 28 TWD 19 TWD 20 TWD 17 TWD 34 TWD 10 TWD 15 TWD 21 TWD 14 TWD 24 TWD 27 TWD 20 TWD 16 TWD 33 TWD 27 TWD 27 TWD 29 TWD 21 TWD 19 TWD 20 TWD 31 TWD 19 TWD 20 TWD 15 TWD 16 TWD 15 TWD 13 TWD 16 VS3 VS3 DCB DHB VS3 01H 01C 02H DHT DHB VS3 VS3 DCB VS3 VS3 VS3 04H VS3 VS3 DHT VS3 VS3 DCT DCT VS3 VS3 VS3 01C 07C VS3 DCB VS3 VS3 01C VS3 VS3 VS3 DCB VS3 DHB DHB DCT DHT DCB 07C VS3 DCT DCB VS3 VS3 VS3 VS3 VS3 DCT

+0.98

-1.05

+0.00

+0.00

-1.08

+0.83

+0.15

+0.97

+0.00

+0.00

-1 04

-0.45

+0.00

-0.88

-0.87

+0.81

+0.85

+0.73

-0.81

-0.07

-0.70

+0.81

-0.25

-0.25

-0.80

+0.71

-0.86

-0.93

-0.79

-0.85

+1.01

-0.45

-0.67

+0.96

+0.91

-0.91

+0.70

+0.13

-0.68

+0.00

+0.00

+0.00

+0.00

+0.00

-0.94

-0.83

+0.00

+0.00

-1.07

+0.99

+0.51

+0.87

+0.77

+0.00 TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEH TEC TEH TEC TEH TEC TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEC TEH TEH TEC TEH TEC TEH TEC TEH TEC 16 16 13 13 27 8

7 98 13 51 51 51 51 34 15 33 103 102 15 14 14 14 14 16 4

5 34 8

13 107 16 31 5

7 ill 20 18 14 106 14 15 15 15 15 6

13 13 13 42 102 21 16 15 15 COLD COLD COLD COLD COLD COLD COLD HOT COLD COLD COLD COLD COLD COLD COLD COLD HOT HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT COLD COLD COLD COLD HOT COLD COLD COLD HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT COLD COLD COLD COLD 600UL 600UL 600UL 60OUL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 60OUL 60OUL 6000L 600UL 600UL 60OUL 60OUL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 60OUL 60OUL 600UL 600UL 60OUL 60OUL 600UL 600UL 60OUL 600UL 60OUL 600UL 60OUL 600UL 600UL 60OUL 600UL 60OUL 600UL 600UL 600UL 600UL 60OUL 60OUL 60OUL 60OUL

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 85 of 92 Areva NP 6/7/2006 9:18 AM Component: S/G B 0 Customer Name: St. Lucie Unit 2 Page 3 of 10 Tubes with Bobbin 1-34 TWD Indications Left In Service ROW LINE VOLTS 46 70 0.95 0.15 46 76 0.34 46 94 0.75 0.73 0.23 46 96 0.41 47 21 0.34 47 93 0.20 47 99 0.36 47 101 0.37 47 105 0.32 0.37 48 58 0.16 48 72 0.31 48 74 0.29 48 82 0.59 0.19 0.27 49 59 0.47 0.28 50 36 0.30 50 72 0.35 50 80 0.61 0.55 50 82 0.37 50 84 0.17 0.41 0.88 50 88 0.32 0.33 50 92 0.51 50 94 0.46 50 98 0.19 50 106 0.44 50 110 0.24 0.26 51 79 0.56 0.47 51 81 0.27 0.71 51 83 0.98 0.68 51 89 0.76 51 95 0.39 51 101 0.14 51 107 0.28 51 115 0.25 51 121 0.28 0.29 51 125 0.24 52 8

0.41 52 74 0.17 52 76 0.79 DEG 127 25 62 112 140 22 152 113 18 145 44 41 66 173 46 174 12 80o 101 133 46 133 153 115 18 138 11 26 125 165 13 38 60 35 92 141 137 145 163 10 141 14 50 94 127 35 75 135 159 72 69 149 158 95 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2-P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWO TWD TWD TWD TWD TWD TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWO TWD TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWO TWD TWD TWD TWD TWD TWD TWO TWO

%TW 34 11 20 29 29 12 20 16 11 16 22 20 22 10 14 18 23

'a 12 24 17 15 20 23 22 21 12 22 33 19 19 23 23 11 21 16 17 27 24 12 26 31 25 29 21 10 15 14 20 19 14 19 12 28 LOCATION Vs3 DCB DHB VS3 DCB DHT DHB VS3 DHT VS3 VS3 VS3 VS3 VS3 VS3 DHB DHT DHB 07H VS3 VS3 VS3 VS3 DHB DCT DCB DHB DHT DCT DHB DCB DHB VS3 VS3 VS3 VS3 VS3 DCB DHT DCT DCB DCT DCB DHB 07H VS3 VS3 VS3 VS3 VS3 VS3

+

o1C VS3

+

VS3

+

+0.80

+0.00

+0.38

-0.86

+0.00

-0.25

+0.00

-0.70

-0.25

-0.77

+0.83

-0.96

+0.75

+0.85

-0.87

-0.11

+0.00

+0.00-

+0.93

-0.89

+0.85

+0.64

-0.85

+0.00

+0.00

+0.33

+0.33

+0.00

+0.00

+0.42

+0.20

+0.00

-1.00

-0.77

+0.98

-0.71

+0.55

+0.42

+0.00

+0.00

+0.00

+0.00

+0.00

+0.00

+0.82

+0.70

+0.91

+0.84

-0.76

+0.79 0.82

-1.07

-0.77 0.86 EXT TEN TEH TEH TEH TEH TEH TEH TEC TEN TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEN TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEN TEH TEH TEH TEH TEC TEH TEH EXT TEC TEC TEC TEC TEC TEC TEC TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC-TEC TEC TEC TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEC TEC CAL # LEG 13 COLD 13 COLD 13 COLD 15 COLD 15 COLD 15 COLD 42 COLD 102 HOT 15 COLD 50 COLD 33 COLD 33 COLD 33 COLD 18 COLD 14 COLD 13 COLD 14 COLD 14 COLD-14 COLD 17 COLD 17 COLD 111 HOT 13 COLD 14 COLD 14 COLD 13 COLD 13 COLD 13 COLD 13 COLD 16 COLD 16 COLD 15 COLD 15 COLD 43 COLD 32 COLD 31 COLD 31 COLD 13 COLD 13 COLD 14 COLD 14 COLD 14 COLD 14 COLD 15 COLD 16 COLD 33 COLD 32 COLD 29 COLD 29 COLD 29 COLD 27 COLD 98 HOT 13 COLD 14 COLD PROBE 60OUL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60UUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600OL 600DL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL

St. Lucie Unit 2 Docket Ns. 50-3 89 L-2007-076 Attachment Page 86 of 92 Areva NP 6/7/2006 9:18 AM Component: S/G B 0 Customer Name-St. Lucia Unit 2 Page 4 of 10 Tubes with Bobbin 1-34 TWD Indications Left In Service ROW LINE VOLTS 52 78 0.37 0.70 0.45 0.75 52 88 0.52 0.90 0.65 52 90 0.42 52 116 0.06 0.46 52 124 0.28 52 146 0.29 0.22 0.82 0.25 53 29 0.17 53 63 0.15 53 81 0.22 0.46 53 83 0.13 53 91 0.20 53 145 0.20 0.20 53 149 0.28 53 151 0.10 54 22 0.30 54 76 0.24 0.21 54 78 0.63 0.38 0.80 54 84 0.48 54 86 0.41 0.16 0.28 54 88 0.23 0.56 54 90 0.21 0.48 0.17 54 92 0.98 0.37 0.17 54 118 0.20 54 122 0.13 54 124 0.65 54 134 0.31 0.40 54 144 0.32 54 146 0.32 54 148 0.11 54 154 0.23 55 15 0.05 55 77 0.87 DEG CHN 100 P2 128 P2 126 P2 38 P2 35 P2 108 P2 65 P2 36 P2 159 P2 29 P2 79 P2 90 P2 152 P2 108 P2 113 P2 149 P2 139 P2 176 P2 103 P2 35 P2 177 P2 108 P2 108 P2 54 P2 51 P2 120 P2 82 P2 125 P2 113 P2 153 P2 55 P2 98 P2 104 P2 24 P2 13 P2 142 P2 62 P2 45 P2 73 P2 84 P2 74 P2 27 P2 22 P2 12 P2 129 P2 22 P2 41 P2 41 P2 16 P2 9

P2 10 P2 13 P2 177 P2 125 P2 IND %TW TWD 16 TWD 26 TWD 19 TWD 27 TWD 23 TWD 32 TWD 27 TWD 22 TWD 4 TWO 22 TWD 16 TWD 16 TWD 14 TWD 23 TWD 10 TWD 17 TWD 11 TWD" 15 TWD 24 TWD 9 TWD 13 TWD 13 TWD 13 TWD 18 TWD 7 TWO 17 TWD 15 TWD 14 TWD 29 TWD 21 TWD 32 TWD 22 TWD 20 TWD 9 TWD 15 TWD 12 TWD 24 TWD 12 TWD 22 TWD 10 TWD 33 TWD 19 TWO 9 TWD 12 TWD 9 TWD 27 TWD 18 TWD 21 TWD 19 TWD 19 TWD 8 TWD 14 TWD 3 TWD 29 LOCATION VS3

-1.09 VS3

+0.77 DCB

+0.00 DCT

+0.00 DHT

+0.00 VS3

+0.88 DCB

+0.39 DCB

-0.07 VS3

-0.96 VS3

+0.75 VS3

-1.06 07C

-0.90 VS3

+0.77 VS3

-1.02 06C

+0.11 VS3

+0.95 VS3

-0.71 DHT.

-0.09 DCT

+0.00 DCB

+3.32 DCT

-0.15 DCB

+1.95 DCT

+0.00 DHT

+0.00 DCB

+0.17 VS3

-0.59 VS3

+0.66 VS3

-0.74 DHB

+0.00 DCT

+0.00 DCB

+0.00 DCT

+0.00 DCT

+0.00 DCB

+0.20 VS3

-1.02 VS3

-0.76 VS3

+0.77 DCT

+0.00 DCB

+0.00 DHT

-0.22 VS3

+0.57 DHT

-0.20 DCT

-0.25 VS3

+0.96 07C

-0.99 VS3

-0.02 VS3

-0.84 DCB

+3.72 DCT

-0.02 DCT

+0.00 DCT

+0.00 VS3

+0.00 04H

+0.83 DCB

+0.00 EXT TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEH TEH-TEH TEH TEH TEH TEH TEH TEH TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEN TEH TEH TEH TEH TEH TEH TEH TEC TEH EXT TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEC CAL 14 14 14 14 15 15 15 16 29 29 28 6

6 6

6 106 17 13 13 13 16 5

5 5

6 102 13 13 13 13 13 15 15 15 15 15 15 15 15 15 15 15 15 30 27 27 4

4 5

5 4

6 103 14

  1. LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT COLD PROBE 600UL 600UL 600UL 60OUL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 60OUL 600UL 60OUL 60OUL 60OUL 600UL 600UL 600UL 600UL 600OL 60OUL 60OUL 60OUL 60OUL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600OL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 60OUL 60OUL 600OL 600UL

St. Lucie Unit 2 Docket Ns. 50-389 Areva NP L-2007-076 Attachment Page 87 of 92 6/7/2006 9:18 AM Component: S/G B Attachment 10 Customer Name: St. Lucie Unit 2 Page 5 of 10 Tubes with Bobbin 1-34 TWD Indications Left In Service ROW LINE VOLTS 55 89 0.30 55 99 0.20 55 125 0.92 55 135 0.35 55 139 0.74 55 159 0.25 56 76 0.30 0.63 56 90 0.35 0.65 56 98 0.22 56 138 0.23 0.20 57 51 0.89 57 77 0.27 0.18 0.20 57 85 0.48 57 137 0.33 0.16 57 155 0.17 58 84 0.22 60 10 0.23 60 80 0.59 60 86 0.22 60 134 0.59 60 152 0.12 0.21 61 155 0.16 62 12 0.21 62 18 0.15 62 46 0.29 0.20 62 88 0.60 62 98 0.26 62 124 0.14 62 158 0.10 63 79 0.26 64 34 0.48 64 68 0.20 0.08 64 84 0.19 64 152 0.29 0.46 67 29 0.17 68 50 0.30 0.49 68 136 0.14 69 153 0.15 71 97 0.27 0.61 73 135 0.23 76 146 0.35 0.26 DEG CHN 46 P2 99 P2 108 P2 127 P2 44 P2 17 P2 52 P2 83 P2 54 P2 97 P2 154 P2 146 P2 149 P2 70 P2 76 P2 95 P2 146 P2 136 P2 53 P2 134 P2 19 P2 160 P2 160 P2 46 P2 117 P2 119 P2 107 P2 129 P2 77 P2 139 P2 139 P2 54 P2 80 P2 59 P2 154 P2 156 P2 88 P2 52 P2 30 P2 79 P2 81 P2 56 P2 50 P2 105 P2 169 P2 70 P2 121 P2 19 P2 161 P2 108 P2 123 P2 38 P2 57 P2 53 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW 16 11 31 19 30 15 13 24 18 27 13 15 14 33 17 12 13 22 18 11 12 12 16 23 14 26 9

13 8

11 10 17 13 25 16 9

2 16 23 12 5

10 17 23 12 17 24 10 10 16 27 14 20 16 LOCATION DHB

+0.00 VS3

+1.04 VS3

-0.93 DCT

+0.04 VS3

+0.75 DHT

+0.00 VS3

-0.96 VS3

+0.79 VS3

-0.29 DCT

+0.00 VS3

+0.68 VS3

-0.85 VS3

+0.80 VS3

-0.93 VS3

-0.85 VS3

+0.59 DCB

+0.07 DCB

+0.00 VS3

+0.72 VS3

-0.86 DCT

-0.09 DCT

-0.24 02H

+0.71 DCB

+0.00 VS3

-0.71 VS3

-0.76 VS4

-0.81 VS3

+0.87 VS2

+0.97 01H

-0.98 VS3

-0.88 VS2

+0.74 VS3

+1.02 VS3

-0.74 VS3

-0.69 05C

+0.93 VS3

-1.10 DCB

+0.00 VS4

-0.24 VS2

+0.71 V54

-0.91 VS3

-0.84 VS4

-1.07 VS2

-0.67 VS2

-0.80 VS2

+0.84 VS3

-1.08 06H

+0.94 Vs4

-0.89 VS2

+0.63 VS4

-0.74 VS3

+0.72 VS

+0.64 VS3

+0.88 EXT EXT TEN TEC TEH TEC TEH TEC TEH TEC TEH TEC TEN TEC TER TEC TER TEC TEH TEC TEN TEC TEN TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC.-

TEN TEC TEN TEC TEN TEC TEH TEC TEC TEH TEN TEC TEN TEC TEN TEC TER TEC TEN TEC TEN TEC TEC TEN TEC TEN TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEC TEN TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEC TEN TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC CAL #

15 43 28 6

5 8

14 14 15 15 42 5

5 19 13 13 13 15 4

4 5

15 97 14 16 4

4 4

3 98 103 19 19 15 16 27 3

13 112 15 15 15 4

4 107 19 19 4

4 15 15 4

3 3

LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD HOT COLD COLD COLD COLD COLD COLD HOT HOT COLD COLD COLD COLD COLD COLD COLD HOT COLD COLD COLD COLD COLD HOT COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 600LUL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 60OUL 600UL 600UL

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 88 of 92 Areva NP 6/7/2006 9:18 AM Component: S/G B 0 Customer Name: St. Lucie Unit 2 Page 6 of 10 Tubes with Bobbin 1-34 TWD Indications Left In Service ROW LINE VOLTS 0.17 77 141 0.28 80 138 0.30 81 25 0.38 81 39 0.25 81 57 0.27 82 34 0.15 83 39 0.18 0.23 83 55 0.35 0.22 85 41 0.12 85 129 0.28 85 147 0.22 86 48 0.31 86 148 0.13 87 23 0.39 87 83 0.34 87 131 0.24 87 135 0.21 0.21 88 24 0.10 0.19 88 28 0.25 0.06 88 70 0.20 88 78 0.55 0.33 88 84 0.48 88 86 0.61 88 98 0.16 88 108 0.13 88 128 0.26 88 134 0.25 88 138 0.40 89 29 0.42 89 83 1.00 0.13 89 89 0.33 89 97 0.21 89 111 0.76 89 117 0.55 0.20 0.15 89 135 0.46 0.16 0.12 90 112 0.24 91 25 0.31 91 27 0.32 91 29 0.31 91 101 0.15 92 24 0.27 92 28 0.11 DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 32 P2 27 P2 113 P2 31 P2 66 P2 96 P2 27 P2 26 P2 14 P2 169 P2 165 P2 151 P2 126 P2 49 P2 68 P2 162 P2 72 P2 93 P2 155 P2 157 P2 51 P2 100 P2 104 P2 107 P2 21 P2 9

P2 87 P2 53 P2 137 P2 134 P2 33 P2 11 P2 67 P2 92 P2 144 P2 173 P2 90 P2 169 P2 146 P2 104 P2 73 P2 110 P2 151 P2 139 P2 117 P2 66 P2 19 P2 161 P2 132 P2 106 P2 120 P2 93 P2 142 P2 148 P2 TWO 9 TWD 16 TWO 18 TWD 18 TWD 15 TWD 15 TWD 8 TWD 10 TWO 13 TWO 19 TWD 12 TWD 8 TWO 15 TWO 13 TWD 15 TWO 9 TWO 18 TWD 18 TWO 13 TWD 14 TWD 14 TWO 7 TWD 12 TWD 15 TWD 5 TWD 12 TWO 24 TWD 17 TWD 24 TWD 27 TWO 9 TWD 7 TWD 15 TWO 15 TWO 22 TWD 19 TWD 34 TWD 9 TWO 21 TWD 15 TWD 29 TWO 23 TWD 11 TWD 9 TWD 21 TWD 9 TWD 7 TWD 14 TWD 16 TWD 16 TWO 17 TWD 9 TWD 16 TWD 8 VS4 OCT 08C OCT VS4 VS4 VS4 VS2 VS4 VS3 VS4 VS4 DOB VS2 VS2 02C VS2 VS3 VS2 VS2 VS3 VS3 VS2 VS3 VS3 04H VS2 VS2 VS2 VS3 06C 05H 08C VS2 DCB DHT VS3 VS2 VS2 VS4 VS4 VS2 07H 07H DCB VS2 VS2 06H OCT VS4 OCT VS2 DCB VS2

-0.77

-0.13

-1.06

+0.00

+0.71

-0.77

-0.79

+0.62

+0.64

-0.37

+0.82

-0.98

+0.17

-0.99

+0.98

-0.13

+0.71

-1.08

-0.36

-1.07

-0.91

+0.69

+0.62

+0.86

-0.09

+0.69

+0.93

-0.97

+0.83

+0.77

+1.01

+0.74

-0.88

-0.82

+0.11

+0.00

-1.00

-0.96

-1.16

-0.91

-0.71

-1.23

-0.96

+0.52

+0.00

-0.97

+0.86

+0.94

-0.12

-0.98

+0.00

-1.00

+0.00

+0.86 TEN TEC TEH TEC TEN TEC TEN TEC TEN TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC TEN TEC TEH TEC TEN TEC TER TEC TEN TEC TEN TEC TEN TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC TEN TEC TEN TEC TEN TEC TER TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC 3

4 3

53 52 55 53 53 53 54 54 55 35 34 55 34 53 46 35 33 33 52 52 52 52 45 46 46 47 69 48 41 36 36 33 53 47 47 49 49 40 38 38 38 34 34 34 40 53 53 52 39 52 52 COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL..

600UL 60OUL 600UL 60OUL 60OUL 600UL 60OUL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 60OUL 60OUL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 89 of 92 Areva NP 6/7/2006 9:18 AM Component: S/G B 0 Customer Name: St. Lucie Unit 2 Page 7 of 10 Tubes with Bobbin 1-34 TWD Indications Left In Service ROW LINE VOLTS 0.18 92 30 0.21 0.35 0.10 0.16 0.23 92 34 0.18 92 38 0.18 92 92 0.18 92 102 0.24 92 118 0.31 92 142 0.44 93 23 0.20 93 47 0.23 93 49 0.48 93 97 0.38 0.22 93 101 0.35 0.64 93 123 0.17 93 127 0.15 93 129 0.20 93 139 0.10 94 24 0.43 94 26 0.36 0.35 0.37 94 36 0.24 94 44 0.16 0.37 94 98 0.24 94 100 0.33 0.90 0.89 94 102 0.35 94 104 0.19 94 122 0.28 94 124 0.41 0.36 94 126 0.51 0.38 0.30 0.29 94 136 0.12 0.48 94 144 0.28 0.17 0.09 0.26 95 25 0.10 0.22 95 27 0.22 95 29 0.17 0.19 DEG 32 160 146 25 112 126 57 112 64 42 22 105 96 148 106 108 56 27" 51 156 128 48 56 73 160 89 134 153 16 151 54 79 115 71 70 148 56 97 103 ill 144 154 62 110 118 99 39 49 15 163 147 84 31 31 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW LOCATION 12 VS2

-0.71 13 VS4

-0.95 19 VS2

+0.75 7

VS2

+0.02 11 07H

+0.87 14 07H

-0.84 12 08H

+0.93 12 08H

-0.99 10 06H

+0-.92 14 VS2

+0.82 16 DHB

+0.00 21 VS2

+0.73 13 DCT

-0.11 13 VS2

-0.88 23 VS2

-0.75 23 vS2

+0.70 16 VS4

+0.83 17 VS3"

-0.58 26 VS2

-0.95 11 VS3

+0.75 10 VS3

+0.79 12 DCB

+0.00 6

06H

+0.88 20 DCB

+0.00 17 DHT

-0.24 17 VS2

-1.01 18 VS2

+0.95 13 VS2

-0.79 8

VS2

-0.77 20 VS4

-1.08 13 VS2

+0.77 17 VS4

+1.06 31 VS2

-1.22 30 VS2

+0.67 18 VS3

-0.80 11 08C

+0.88 16 VS2

-0.95 21 VS2

-1.06 19 VS3

-0.86 23 VS2

-1.08 19 VS3

-0.89 16 VS4

+0.84 11 DHB

+0.00 7

VS4

-0.21 22 VS4

+0.94 18 VS2

-0.69 12 VS2

+0.94 7

VS3

-1.09 17 VS4

+0.89 6

05H

+0.90 12 VS4

-0.75 12 VS4

-0.90 12 06H

+0.77 12 VS2

+0.82 EXT EXT TEN TEC TEN TEC TEN TEC TEH TEC TEN TEC TEH TEC TEH TEC TEN TEC TEN TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TER TEC TEN TEC TEN TEC-TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TER TEC TEN TEC TEN TEC TEN TEC TEN TEC TER TEC TEH TEC TEN TEC TEN TEC TER TEC TEH TEC TEH TEC TEN TEC TEN TEC TEN TEC TEH TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEN TEC TEH TEC CAL #

52 52 52 52 52 52 52 52 48 39 39 34 52 54 54 49 49 38 38 36 36 36 34 53 53 53 53 53 54 54 48 38 38 38 38 38 36 36 36 35 35 35 35 34 34 33 33 33 33 53 53 53 52 52 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD' COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL

St. Lucie Unit 2 L-2007-076 Docket Ns. 50-389 Attachment Page 90 of 92 Areva NP 6/7/2006 9:18 AM 0 Customer Name: St. Lucie Unit 2 Component:

S/G B Page 8 of 10 Tubes with Bobbin 1-34 TWD Indications Left In Service ROW LINE VOLTS DEG CHN IND %TW LOCATION EXT EXT CAL # LEG PROBE 0.51 90 P2 TWD 24 DCT

+0.00 TEH TEC 52 COLD 600UL 95 41 0.26 56 P2 TWD 14 VS4

+0.99 TEN TEC 54 COLD 60OUL 0.42 123 P2 TWD 21 VS2

+0.73 TEN TEC 54 COLD 600UL 0.20 12 P2 TWD 11 DCB

+0.00 TEN TEC 54 COLD 600UL 95 55 0.27 23 P2 TWD 17 DHB

+0.26 TEH TEC 58 COLD 600UL 95 85 0.26 135 P2 TWD 16 VS2

-0.91 TEH TEC 47 COLD 600UL 95 87 0.28 40 P2 TWD 15 VS3

-0.87 TEH TEC 48 COLD 600UL 95 95 0.26 90 P2 TWD 18 VS4

-0.70 TEN TEC 49 COLD 600UL 0.33 122 P2 TWD 21 VS2

+1.04 TEN TEC 49 COLD 600UL 95 99 0.24 134 P2 TWD 17 08C

+0.94 TEH TEC 49 COLD 60OUL 95 101 0.26 147 P2 TWD 15 08H

+0.87 TEN TEC 39 COLD 600UL 95 113 0.14 143 P2 TWD 9 VS2

+1.00 TEN TEC 40 COLD 600UL 0.18 128 P2 TWD 11 VS2

-0.44 TEN TEC 40 COLD 600UL 95 127 0.23 66 P2 TWD 13 VS2

-0.46 TEN TEC 35 COLD 600UL 95 129 0.15 159 P2 TWD 8 VS2

+0.69 TEN TEC 35 COLD 600UL 95 131 0.40 77 P2 TWD 19 VS2

-0.58 TEN TEC 35 COLD 600UL 95 143 0.56 106 P2 TWD 27 VS2

-0.69 TEN TEC 33 COLD 600UL 96 24 0.16 74 P2 TWD 11 06H

+0.84 TEN TEC 52 COLD 600UL 0.43 147 P2 TWD 22 07H

-0.24 TEN TEC 52 COLD 600UL 0.64 100 P2 TWD 27 08H

-0.88 TEN TEC 52 COLD 600UL 0.65 126 P2 TWD 27 VS4

+0.82 TEN TEC 52 COLD 600UL 0.55 120 P2 TWD 25 DCB

+0.00 TEN TEC 52 COLD 600UL 0.10 157 P2 TWD 7 08H

+0.26 TEN TEC 52 COLD 600UL 96 26 0.40 25 P2 TWD 21 VS4

+0.26 TEN TEC 52 COLD 600UL 0.47 26 P2 TWD 23 DHT

+0.00 TEN TEC 52 COLD 600UL 0.14 140 P2 TWD 10 VS2

+1.08 TEN TEC 52 COLD 60OUL 0.22 15 P2 TWD 14 VS3

-0.89 TEN TEC 52 COLD 600UL 96 30 0.28 29 P2 TWD 16 VS4

+0.86 TEN TEC 52 COLD 600UL 96 34 0.21 57 P2 TWD 14 VS3

+0.47 TEN TEC 52 COLD 600UL 1.00 102 P2 TWD 32 VS2

-0.70 TEN TEC 52 COLD 600UL 96 36 0.36 82 P2 TWD 19 VS2

-0.82 TEN TEC 52 COLD 600UL 96 66 0.24 123 P2 TWD 14 VS4

+0.75 TEN TEC 57 COLD 600UL 96 78 0.89 77 P2 TWD 32 VS2

-0.98 TEN TEC 47 COLD 60OUL 0.32 46 P2 TWD 19 VS3

+0.13 TEN TEC 47 COLD 600UL 0.39 48 P2 TWD 22 VS4

+0.62 TEN TEC 47 COLD 60OUL 0.29 165 P2 TWD 18 DCT

+0.00 TEN TEC 47 COLD 600UL 96 92 0.17 162 P2 TWD 10 05C

+0.98 TEN TEC 48 COLD 600UL 96 108 0.60 137 P2 TWD 24 VS2

-0.78 TEN TEC 41 COLD 600UL 0.32 45 P2 TWD 15 VS4

+1.08 TEN TEC 41 COLD 600UL 0.13 158 P2 TWD 7 04H

+0.85 TEN TEC 41 COLD 60OUL 0.13 47 P2 TWD 7 03H

+0.91 TEN TEC 41 COLD 600UL 96 114 0.91 113 P2 TWD 30 VS2

-0.91 TEN TEC 41 COLD 600UL 0.78 70 P2 TWD 27 VS2

-0.11 TEN TEC 41 COLD 600UL 0.46 64 P2 TWD 20 VS2

+0.60 TEN TEC 41 COLD 600UL 0.43 95 P2 TWD 19 VS3

-0.86 TEH TEC 41 COLD 600UL 0.61 55 P2 TWD 24 VS3

-0.02 TEN TEC 41 COLD 600UL 0.57 65 P2 TWD 23 VS4

+0.67 TEN TEC 41 COLD 600UL 96 120 0.33 147 P2 TWD 18 VS3

-0.92 TEN TEC 36 COLD 600UL 0.17 61 P2 TWD 11 VS3

+0.73 TEN TEC 36 COLD 600UL 0.21 60 P2 TWD 13 VS2

+0.94 TEN TEC 36 COLD 600UL 97 27 0.24 90 P2 TWD 15 VS3

-0.93 TEN TEC 52 COLD 600UL 97 41 0.93 73 P2 TWD 30 VS2

+0.73 TEN TEC 55 COLD 600UL 0.30 40 P2 TWD 16 VS3

-0.85 TEN TEC 55 COLD 600UL 0.27 139 P2 TWD 15 VS4

-0.85 TEN TEC 55 COLD 600UL

St. Lucie Unit 2 Docket Ns. 50-389 Areva NP L-2007-076 Attachment Page 91 of 92 6/7/2006 9:18 AM Component: S/G B 0 Customer Name: St. Lucie Unit 2 Page 9 of 10 Tubes with Bobbin 1-34 TWO Indications Left In Service ROW LINE VOLTS 0.79 97 71 0.42 97 103 0.05 97 109 0.46 0.25 97 121 0.20 98 28 0.18 98 62 0.12 98 84 0.20 99 27 0.43 99 107 0.20 100 28 0.22 0.88 100 36 0.23 100 88 0.46 100 90 0.15 101 27 0.77 102 60 0'.21 102 92 0.16 102 122 0.24 103 75 0.17 103 137 0.24 104 30 0.26 104 134 0.29 105 33 0.23 106 62 0.15 107 31 0.29 0.29 107 51 0.25 107 89 0.11 108 32 0.23 108 34 0.27 108 90 0.11 108 136 0.50 109 89 0.18 110 92 0.14 ill 77 0.14 111 133 0.21 112 38 0.21 112 118 0.13 113 51 0.37 0.29 116 38 0.41 117 39 0.35 120 44 0.13 121 43 0.31 121 51 0.25 121 57 0.20 122 86 0.31 123 45 0.27 124 46 0.23 125 47 0.34 0.26 126 48 0.16 DEG CHN 93 P2 99 P2 182 P2 23 P2 43 P2 165 P2 101 P2 32 P2 151 P2 105 P2 99 P2 76 P2 116 P2 14 P2 165 P2 104 P2 108 P2 155 P2 40 P2 36 P2 44 P2 19 P2 161 P2 101 P2 74 P2 105 P2 61 P2 54 P2 17 P2 158 P2 143 P2 151 P2 10 P2 137 P2 140 P2

.77 P2 49 P2 99 P2 96 P2 90 P2 38 P2 85 P2 56 P2 41 P2 152 P2 94 P2 157 P2 34 P2 22 P2 156 P2 13 P2 142 P2 19 P2 150 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW LOCATION 28 VS4

+0.73 20 VS4

+0.75 3

DHB

+3.75 20 VS2

+0.63 13 VS2

-0.93 13 VS2

-0.84 10 VS2

+0.99 8

VS2

-0.86 12 VS5

-0.89 20 08H

-0.26 11 DHT

+0.00 14 02H

+0.83 31 DCT

+0.00 14 08H

+0.57 25 08C

-0.94 12 06C

+0.06 29 DCT

+0.00 13 VS4

-0.73 10 VS4

-0.68 14 VS1

-0.81 10 VS2

+0.94 16 VS2

+0.49 16 VS3

-1.30 17 VSI

+0.68 14 02H

-0.15 10 VS1

+0.13 17 04C

-0.96 17 02H

+0.89 16 07C

+0.67 9

05H

+0.81 14 02H

-0.90 16 03C

-0.96 9

02H

+0.91 26 02C

-0.85 10 06C

+0.93 9

07C

-0.11 8

VS3

+0.85 12 05C

+0.24 13 VS4

-0.81 14 VS1

+0.73 19 02H

-0.13 16 02H

+0.90 21 VS3

+0.90 19 DCT

-0.17 8

04H

+0.85 17 DCT

+0.00 14 05H

+0.96 13 VSI

+0.86 19 06H

+0.75 15 DHT

+0.00 12 DCT

+0.00 18 09C

+0.58 15 DCT

+0.00 8

07H

-0.99 EXT TEW TEW TEH TER TEH TEH TEH TEH TEH TEH TER TEH TEH TEH TEH TER TEN TEH TEW TEW TEH TEH TEH TEW TEH TEW TEW TEW TEH TEH TEH TEH TEH TEH TEW TEH TEH TEH TEH TEH TEH TER TEH TEH TEW TEH TEH TEH TEW TEH TEH TEW TEH TEH EXT TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC CAL #

55 45 39 41 41 36 53 57 46 53 41 52 52 52 49 49 52 57 48 36 45 33 52 36 52 57 52 52 58 49 52 52 49 33 48 48 45 35 52 38 57 57 52 52 55 54 55 59 47 54 54 54 54 54 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 600UL 600UL 600UL 600UL 600UL 60CUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 60OUL 60OUL 600UL1 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 60CUL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 600UL

St. Lucie Unit 2 Docket Ns. 50-389 L-2007-076 Attachment Page 92 of 92 Areva NP 6/7/2006 9:18 AM Component: S/G B 0 Customer Name: St. Lucie Unit 2 Page 10 of 10 Tubes with Bobbin 1-34 TWO Indications Left In Service ROW LINE VOLTS 0.80 126 104 0.17 126 112 0.32 127 53 0.19 0.17 0.10 0.35 127 59 0.41 128 52 0.11 128 112 0.38 129 59 0.24 130 58 0.34 131 55 0.26 0.79 131 59 0.90 132 58 0.70 0.55 0.12 132 60 0.39 132 80 0.28 132 110 0.33 133 59 0.49 133 61 0.52 0.19 0.17 133 87 0.17 133 109 0.24 0.27 134 60 0.46 0.20 134 68 0.37 135 63 0.51 135 101 0.89 137 75 0.23 137 99 0.24 DEG 59 11 24 70 154 157 149 23 11 94 17 35 119 78 79 71 94 130-89 33 128 43 133 104 164 141 117 123 87 125 119 32 76 150 150 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD

%TW 30 11 17 12 10 7

18 21 8

18 13 16 16 30 30 29 25 9

18 18 16 24 24 12 11 12 12 13 23 13 20 24 29 16 12 LOCATION DHT

+0.00 VS1

-1.04 VS1

-0.90 DCB

+0.00 06H

-0.85 06H

-0.17 07H

+0.80 09H

+0.90 DHT

+0.00 DCT

-0.12 DCT

+0.00 DCT

+0.00 05H

-0.98 DCB

+0.00 DCT

+0.00 VS1

-0.85 DCB

+0.47 07H

+0..78 DCT

+0.00 VS1

+0.78 VS5

+0.80 DCB

+0.00 DHT

-0.24 09H

+0.22 09H

-1.13 08H

+0.82 08H

+0.75 08H

-0.38 DHB

+0.45 DCT

+0.00 DHB

+0.00 DHT

+0.00 VS1

+0.66 05H

+0.88 VS1

+0.95 EXT TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH-TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH EXT TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC.

TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC CAL #

54 38 40 57 57 57 57 59 58 41 60 60 59 59 60 59 59 59 60 61 62 59 59 59 59 61 62 62 59 59 59 59 62 61 62 LEG COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD...

COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD COLD PROBE 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL.,

600UL 600UL 600UL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL 600UL 600UL 600UL 60OUL 600UL 600UL Total Tubes

370 Total Records: 521