L-2006-127, Special Report, Steam Generator Tube Plugging Report

From kanterella
Jump to navigation Jump to search
Special Report, Steam Generator Tube Plugging Report
ML061520494
Person / Time
Site: Saint Lucie NextEra Energy icon.png
Issue date: 05/18/2006
From: Johnston G
Florida Power & Light Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-2006-127
Download: ML061520494 (1)


Text

Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 May 18, 2006 FPL L-2006-127 10 CFR 50.36 10 CFR 50.4 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Re:

St. Lucie Unit 2 Docket No. 50-389 Special Report Steam Generator Tube Plugging Report This letter is being sent pursuant to St. Lucie Unit 2 Technical Specification 4.4.5.5.a. The number of tubes plugged in each steam generator during the Unit 2 refueling outage (SL2-16) is listed below.

Steam Generator 2A - 463 Steam Generator 2B - 627 Cumulative tubes plugged during this outage and previous outages:

Steam Generator 2A - 1932 Steam Generator 2B - 2336 Please contact us should you have any questions regarding this information.

Very truly yours, Gordon L. Johnsto Acting Vice Presid St. Lucie Plant GLJ/spt bSDU an FPL Group company