L-20-297, Spent Fuel Storage Cask Registration

From kanterella
Jump to navigation Jump to search
Spent Fuel Storage Cask Registration
ML20323A061
Person / Time
Site: Beaver Valley, 07201043
Issue date: 11/18/2020
From: Grabnar J
Energy Harbor Nuclear Corp
To:
Document Control Desk, Office of Nuclear Material Safety and Safeguards, Office of Nuclear Reactor Regulation
References
L-20-297
Download: ML20323A061 (2)


Text

Energy Harbor Nuclear Corp.

Beaver Valley Power Station P.O. Box 4 Shippingport, PA 15077 John J. Grabnar Site Vice President, Beaver Valley Nuclear 724-682-5234 November 18, 2020 L-20-297 10 CFR 72.212 ATTN: Document Control Desk Director, Division of Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

SUBJECT:

Beaver Valley Power Station, Unit Nos. 1 and 2 Docket No. 50-334, License No. DPR-66 Docket No. 50-412, License No. NPF-73 Docket No. 72-1043 Spent Fuel Storage Cask Registration In accordance with the registration requirements of 10 CFR 72.212(b)(2), Energy Harbor Nuclear Corp. is providing the enclosed information to register spent fuel storage casks at the Beaver Valley Power Station (BVPS) independent spent fuel storage installation (ISFSI).

There are no regulatory commitments contained in this letter. If there are any questions or if additional information is required, please contact Phil H. Lashley, Manager - Fleet Licensing at (330) 696-7208 Sincerely, John J. Grabnar

Attachment:

Spent Fuel Storage Cask Registration Information cc: NRC Region I Administrator NRC Resident Inspector NRC Project Manager Director BRP/DEP Site BRP/DEP Representative

Attachment L-20-297 Spent Fuel Storage Cask Registration Information Page 1 of 1 The following information is provided in accordance with 10 CFR 72.212(b)(2) for registration of the spent fuel storage casks at the Beaver Valley Power Station:

Licensee Name:

Energy Harbor Nuclear Corp.

Licensee Address:

Beaver Valley Power Station P.O. Box 4, Route 168 Shippingport, Pennsylvania 15077 Reactor License Number:

DPR-66 (Unit No. 1), NPF-73 (Unit No. 2)

Reactor Docket Number:

50-334 (Unit No. 1), 50-412 (Unit No. 2)

Independent Spent Fuel Storage Installation Docket Number: 72-1043 Contact Name and

Title:

Phil H. Lashley, Manager - Fleet Licensing Cask Certificate Number and Certificate of Compliance (CoC)

Amendment Number:

1042; Amendment 1 Cask Model Number:

EOS-37PTH Service Date:

October 23, 2020 Cask Identification Number:

Dry Shielded Canister (DSC) Serial Number: BV-EOS-37PTH-11-B4H/B4L Horizontal Storage Module (HSM) Serial Number: BV-3-HSM-11 Service Date:

October 29, 2020 Cask Identification Number:

Dry Shielded Canister (DSC) Serial Number: BV-EOS-37PTH-12-B4H/B4L Horizontal Storage Module (HSM) Serial Number: BV-3-HSM-12