L-17-198, Emergency Response Data System Data Point Library Update
| ML17180A321 | |
| Person / Time | |
|---|---|
| Site: | Beaver Valley |
| Issue date: | 06/16/2017 |
| From: | Richey M FirstEnergy Nuclear Operating Co |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| L-17-198 | |
| Download: ML17180A321 (15) | |
Text
.* FE NOC' RrstEnergy Nuclear Operating Company Marty L. Richey Site Vice President Beaver Valley Power Station P.O. Box4 Shippingport, PA 15077 724-682-5234 Fax: 724-643-8069 June 16, 2017 L-17-198 10 CFR 50, Appendix E, Section VI ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001
SUBJECT:
Beaver Valley Power Station, Unit No. 1 Docket No. 50-334, License No. DPR-66 Emergency Response Data System Data Point Library Update In accordance with reporting requirement 10 CFR 50; Appendix E, Section Vl.3.a, updates of the Emergency Response Data System (EROS) Data Point Library (DPL) for Beaver Valley Power Station, Unit No. 1 (BV1) are provided. The attachment includes the required details of the changes, and the enclosure provides copies of the updated DPL pages.
There are no regulatory commitments contained in this letter. If there are any questions or if additional information is required, please contact Mr. Brian D. Kremer, Manager -
Regulatory Compliance, at 724-682-4284.
Sincerely,
Attachment:
S 1 mmary of Changes to Data Point Library
Enclosure:
Beaver Valley Power Station EROS Data Point Library, Updated Pages cc:
NRG Region I Administrator NRG Resident Inspector NRG Project Manager (w/o enclosure)
Director BRP/DEP Site BRP/DEP Representative
Reactor DPL Unit Point BVl R1011A BVl R1013A BVl
.R1021A BVl R1023A BVl R1031A BVl R1033A BVl XR013 BVl XR015 BVl XR005 BVl XR007 BVl XR009 BVl XROll Attachment L-17-198 Summary of Changes to Data Point Library Page 1 Description of Change(s)
Create new point named R1011A with same fields as XR013.
Date: changed to "5/30/i7", Data Feeder: changed to "IPC" Create new point named R1013A with same fields as XR015.
Date: changed to "5/30/17", Data Feeder: changed to "IPC" Create new point named R1021A with same fields as XR005.
Date: changed to "5/30/17", Data Feeder: changed to "IPC" Create new point named R1023A with same fields as XR007.
Date: changed to "5/30/17", Data Feeder: changed to "IPC" Create new point named R1031A with same fields as XR009.
Date: changed to "5/30/17", Data Feeder: changed to "IPC" Create new point named R1033A with same fields as XROll.
Date: changed to "5/30/17", Data Feeder: changed to "IPC" Date: changed to "5/30/17" Unique System Desc.: "Point deleted per ECP-14-0464" Clear all other fields except Date, Reactor Unit, Data Feeder, Point ID.
Date: changed to "5/30/17" Unique System Desc.: "Point deleted per ECP-14-0464" Clear all other fields except Date, Reactor Unit, Data Feeder, Point ID.
Date: changed to "5/30/17" Unique System Desc.: "Point deleted per ECP-14-0464" Clear all other fields except Date, Reactor Unit, Data Feeder, Point ID.
Date: changed to "5/30/17" Unique System Desc.: "Point deleted per ECP-14-0464" Clear all other fields except Date, Reactor Unit, Data Feeder, Point ID.
Date: changed to "5/30/17" Unique System Desc.: "Point deleted per ECP-14-0464" Clear all other fields except Date, Reactor Unit, Data Feeder, Point ID.
Date: changed to "5/30/17" Unique System Desc.: "Point deleted per ECP-14-0464" Clear all other fields except Date, Reactor Unit, Data Feeder, Point ID.
Enclosure L-17-198 Beaver Valley Power Station EROS Data Point Library, Updated Pages (12 pages follow)
BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date:
5/30/2017 Reactor Unit:
BV1 Data Feeder:
ARERAS NRC EROS Parameter:
Point ID:
XR005 Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarmffrip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
point deleted per ECP 14-0464 1-78
BEAVER VALLEY POWER STATION EROS DAT A POINT LIBRARY Date:
5/30/2017 Reactor Unit:
BV1 Data Feeder:
ARERAS NRC EROS Parameter:
Point ID:
XR007 Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
AlarmfTrip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
point deleted per ECP 14-0464 1-80
BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date:
5/30/2017 Reactor Unit:
BV1 Data Feeder:
ARERAS NRG EROS Parameter:
Point ID:
XR009 Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm!Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
point deleted per ECP 14-0464 1-81
BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date:
5/30/2017 Reactor Unit:
BV1 Data Feeder:
ARERAS NRG EROS Parameter:
Point ID:
XR011 Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarmffrip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
point deleted per ECP 14-0464 1-83
BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date:
5/30/2017 Reactor Unit:
BV1 Data Feeder:
ARERAS NRC ERDS Parameter:
Point ID:
XR013 Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm!Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
point deleted per ECP 14-0464 1-84
BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date:
5/30/2017 Reactor Unit:
BV1 Data Feeder:
ARERAS NRG EROS Parameter:
Point ID:
XR015 Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
AlarmfTrip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
point deleted per ECP 14-0464 1-86
BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date:
5/30/2017 Reactor Unit:
BV1 Data Feeder:
IPC NRC EROS Parameter:
EFF-GAS-RAD1 Point ID:
R1021A Plant Spec Point Desc.:
1RM-VS-109 LRNGM Generic/Cond Desc.:
RADIOACTIVITY OF RELEASED GASSES Analog/Digital:
A Engr Units/Dig States:
uCi/sec Engr Units Conversion:
Xe133 CF= cps/uCl/cc Minimum Instr Range:
2.9E+01 Maximum Instr Range:
2.9E+05 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number of Sensors:
How Processed:
N/A Sensor Location:
SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points:
Alert=7.92E+2, High=1.584E+3 NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-ON Power Level:
N/A Instrument Failure Mode:
DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.:
1 minute average data. System design is such that either the RM-1VS-109 low range or high range noble gas monitor for each pathway will be in service. At a concentration of 1 E-2 uCi/cc on the low range monitor, flow will normally swap to the high range monitor. The listed minimum and maximum instrument ranges listed are based on system software parameter limitations and pathway ODCM release flow rate. In addition, the maximum range is based on a release concentration of 1 E-2 uCi/cc, limited by the automatic swap to the high range monitor. Note Because actual pathway release flow rate may vary, the "Minimum Instr Range" and "Maximum Instr Range" may not reflect the actual instrument ranges. Site dose assessment corrects the uCi/s for source term and flow rate differences depending on selected default source term and decay period. RM-1VS-109 monitors for low range noble gases at the discharge of the Auxiliary Building shielded area exhaust fans and at the discharge of the Containment Refueling Purge and Exhaust fan (during refueling). Provides alarms to warn the operator of abnormal releases and provides input to calculate integrated release data.
1-87
BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date:
5/30/2017 Reactor Unit:
BV1 Data Feeder:
IPC NRC EROS Parameter:
EFF-GAS-RAD3 Point ID:
R1023A Plant Spec Point Desc.:
1 RM-VS-109 HRNGM Generic/Cond Desc.:
RADIOACTIVITY OF RELEASED GASSES Analog/Digital:
A Engr Units/Dig States:
uCi/sec Engr Units Conversion:
Xe133 CF= amps/uCl/cc Minimum Instr Range:
1.8E+03 Maximum Instr Range:
7.9E+12 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number of Sensors:
How Processed:
N/A Sensor Location:
SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points:
Alert=5.28E+5, High=1.18E+6 NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-ON Power Level:
N/A Instrument Failure Mode:
DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.:
1 minute average data. System design is such that either the RM-1VS-109 low range or high range noble gas monitor for each pathway will be in service. At a concentration of 1 E-2 uCi/cc on the low range monitor, flow will normally swap to the high range monitor. Minimum and maximum instrument ranges listed are based on Xe-133 and pathway ODCM release flow rate.
Maximum range is based on monitor parameter setting and ODCM release flow rate. Note Because actual pathway release flow rate may vary, the "Minimum Instr Range" and "Maximum Instr Range" may not reflect the actual instrument ranges. Site dose assessment corrects the uCi/s for source term and flow rate differences depending on selected default source term and decay period. RM-1VS-109 monitors for high range noble gases at the discharge of the Auxiliary Building shielded area exhaust fans and at the discharge of the Containment Refueling Purge and Exhaust fan (during refueling). Site dose assessment corrects the uCi/s for source term and flow rate differences depending on selected default source term and decay period. Provides alarms to warn the operator of abnormal releases and provides input to calculate intearated release data.
1-88
BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date:
5/30/2017 Reactor Unit:
BV1 Data Feeder:
IPC NRC EROS Parameter:
EFF-GAS-RAD4 Point ID:
R1031A Plant Spec Point Desc.:
1RM-VS-110 LRNGM Generic/Cond Desc.:
RADIOACTIVITY OF RELEASED GASSES Analog/Digital:
A Engr Units/Dig States:
uCi/sec Engr Units Conversion: Xe133 CF= cps/uCl/cc Minimum Instr Range:
2.3E+01 Maximum Instr Range:
2.3E+05 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number of Sensors:
How Processed:
N/A Sensor Location:
SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points:
Alert=1.137E+3, High=2.27 4E+3 NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-ON Power Level:
N/A Instrument Failure Mode:
DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.: 1 minute average data. System design is such that either the RM-1VS-110 low range or high range noble gas monitor for each pathway will be in service. At a concentration of 1 E-2 uCi/cc on the low range monitor, flow will normally swap to the high range monitor. The listed minimum and maximum instrument ranges listed are based on system software parameter limitations and pathway ODCM release flow rate. In addition, the maximum range is based on a release concentration of 1 E-2 uCi/cc, limited by the automatic swap to the high range monitor. Note Because actual pathway release flow rate may vary, the "Minimum Instr Range" and "Maximum Instr Range" may not reflect the actual instrument ranges. Site dose assessment corrects the uCi/s for source term and flow rate differences depending on selected default source term and decay period. RM-1VS-110 monitors for low range noble gases at the discharge of the Leak Collection Area Exhaust Fans before the Elevated Release Vent. Provides alarms to warn the operator of abnormal releases and provides input to calculate integrated release data.
1-89
BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date:
5/30/2017 Reactor Unit:
BV1 Data Feeder:
EFF-GAS-RAD6 Point ID:
R1033A Plant Spec Point Desc.:
1 RM-VS-110 HRNGM Generic/Cond Desc.:
RADIOACTIVITY OF RELEASED GASSES Analog/Digital:
A Engr Units/Dig States:
uCi/sec Engr Units Conversion:
Xe133 CF = amps/uCl/cc Minimum Instr Range:
1.5E+3 Maximum Instr Range:
6.3E+ 12 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number of Sensors:
How Processed:
N/A Sensor Location:
SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points:
Alert=7.58E+5, High=1.56E+6 NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-ON Power Level:
N/A Instrument Failure Mode:
DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.:
1 minute average data. System design is such that either the RM-1VS-110 low range or high range noble gas monitor for each pathway will be in service. At a concentration of 1 E-2 uCi/cc on the low range monitor, flow will normally swap to the high range monitor. Minimum and maximum instrument ranges listed are based on Xe-133 and pathway ODCM release flow rate.
Maximum range is based on monitor parameter setting and ODCM release flow rate. Note Because actual pathway release flow rate may vary, the "Minimum Instr Range" and "Maximum Instr Range" may not reflect the actual instrument ranges. Site dose assessment corrects the uCi/s for source term and flow rate differences depending on selected default source term and decay period. RM-1VS-110 monitors for high range noble gases at the discharge of the Leak Collection Area Exhaust Fans before the Elevated Release Vent. Site dose assessment corrects the uCi/s for source term and flow rate differences depending on selected default source term and decay period. Provides alarms to warn the operator of abnormal releases and provides input to calculate integrated release data.
1-90
BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date:
5/30/2017 Reactor Unit:
BV1 Data Feeder:
I PC NRG EADS Parameter:
EXTRA 15 Point ID:
R1011A Plant Spec Point Desc.:
1RM-GW-109 LRNGM Generic/Cond Desc.:
RADIOACTIVITY OF RELEASED GASSES Analog/Digital:
A Engr Units/Dig States:
uCi/sec Engr Units Conversion:
Xe133 CF= cps/uCl/cc Minimum Instr Range:
6.8E-1 Maximum Instr Range:
6.8E+3 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number of Sensors:
How Processed:
N/A Sensor Location:
SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points:
Normally n/a NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-ON Power Level:
N/A Instrument Failure Mode:
DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.:
1 minute average data. System design is such that either the RM-1GW-109 low range or high range noble gas monitor for each pathway will be in service. At a concentration of 1 E-2 uCi/cc on the low range monitor, flow will normally swap to the high range monitor. The listed minimum and maximum instrument ranges listed are based on system software parameter limitations and pathway ODCM release flow rate. In addition, the maximum range is based on a release concentration of 1 E-2 uCi/cc, limited by the automatic swap to the high range monitor. Note Because actual pathway release flow rate may vary, the "Minimum Instr Range" and "Maximum Instr Range" may not reflect the actual instrument ranges. Site dose assessment corrects the uCi/s for source term and flow rate differences depending on selected default source term and decay period. RM-1GW-109 monitors for low range noble gases at the discharge of the Gaseous Waste Disposal Blowers. Provides alarms to warn the operator of abnormal releases and provides input to calculate integrated release data.
1-91
BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY Date:
5/30/2017 Reactor Unit:
BV1 Data Feeder:
IPC NRG EROS Parameter:
EXTRA17 Point ID:
R1013A Plant Spec Point Desc.:
1 RM-GW-109 HRNGM Generic/Cond Desc.:
RADIOACTIVITY OF RELEASED GASSES Analog/Digital:
A Engr Units/Dig States:
uCi/sec Engr Units Conversion:
Xe133 CF= amps/uCl/cc Minimum Instr Range:
4.3E+1 Maximum Instr Range:
1.BE+ 11 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number of Sensors:
How Processed:
N/A Sensor Location:
SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points:
Alert=3.27E+5, High=6.55E+5 NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-ON Power Level:
N/A Instrument Failure Mode:
DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.:
1 minute average data. System design is such that either the RM-1GW-109 low range or high range noble gas monitor for each pathway will be in service. At a concentration of 1 E-2 uCi/cc on the low range monitor, flow will normally swap to the high range monitor. Minimum and maximum instrument ranges listed are based on Xe-133 and pathway ODCM release flow rate.
Maximum range is based on monitor parameter setting and ODCM release flow rate. Note Because actual pathway release flow rate may vary, the "Minimum Instr Range" and "Maximum Instr Range" may not reflect the actual instrument ranges. Site dose assessment corrects the uCi/s for source term and flow rate differences depending on selected default source term and decay period. RM-1GW-109 monitors for high range noble gases at the discharge of the Auxiliary Building shielded area exhaust fans and at the discharge of the Gaseous Waste Disposal Blower. Site dose assessment corrects the uCi/s for source term and flow rate differences depending on selected default source term and decay period. Provides alarms to warn the operator of abnormal releases and provides input to calculate integrated release data.
1-92