L-15-247, Emergency Response Data System Data Point Library Update

From kanterella
(Redirected from L-15-247)
Jump to navigation Jump to search
Emergency Response Data System Data Point Library Update
ML15210A254
Person / Time
Site: Beaver Valley
Issue date: 07/27/2015
From: Emily Larson
FirstEnergy Nuclear Operating Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-15-247
Download: ML15210A254 (7)


Text

FENOC-FirstEnergy Nuclear Operating Company Beaver Valley Power Station P.O. Box 4 Shippingport, PA 15077 Eric A. Larson Site Vice President 724-682-5234 Fax.: 724-643-8069 July 27, 2015 L-15-247 10 CFR 50, Appendix E, Section VI ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

SUBJECT:

Beaver Valley Power Station, Unit No. 2 Docket No. 50-412, License No. NPF-73 Emeraencv Response Data System Data Point Library Update In accordance with reporting requirement 10 CFR 50, Appendix E, Section VI.3.a, updates of the Emergency Response Data System (ERDS) Data Point Library (DPL) for Beaver Valley Power Station (BVPS), Unit No. 2 (BV2) are provided. Per letter L-15-046, dated March 2, 2015, FirstEnergy Nuclear Operating Company (FENOC) notified the NRC of changes made to the BVPS Unit No. I (BVI) ERDS DPL that were due to the replacement of a radiation monitoring system. It was not recognized at that time that the BV2 ERDS DPL was also affected by that replacement. This issue has been entered into the corrective action program. The attachment of this letter includes the required details of the changes to the BV2 ERDS DPL, and the enclosure provides copies of the updated DPL pages.

There are no regulatory commitments contained in this letter. If there are any questions or if additional information is required, please contact Mr. William C. Cothen, Manager -

Regulatory Compliance, at 724-682-4284.

Sincerely, Eric A. Larson

Attachment:

Summary of Changes to Data Point Library

Enclosure:

Beaver Valley Power Station ERDS Data Point Library, Updated Pages cc:

NRC Region I Administrator NRC Resident Inspector NRC Project Manager (w/o enclosure)

Director BRP/DEP Site BRP/DEP Representative A 0 )-,

(,c:;,

oe-(-

Attachment L-15-247 Summary of Changes to Data Point Library (Page I of 2)

Reactor DPL Point Description of Change(s)

BV2 XR013 Date: Changed to "02/02/2015" Plant Spec Point Desc: changed to "IRM-GW-109 LRNGM" Engr Units/Dig States: "CPM" to "uCi/sec" Engr Units Conversion: to "Xe 133 CF = cps/uCi/cc" Minimum Instr Range: changed to "6.8E-01" Maximum Instr Range: changed to "6.8E+03" Alarm/Trip Set Points: changed to "normally N/A" Unique System Desc.: changed to I minute average data. System design is such that either the RM-1GW-109 low range or high range noble gas monitor for each pathway will be in service. At a concentration of 1E-02 uCi/cc on the low range monitor, flow will normally swap to the high range monitor. The listed minimum and maximum instrument ranges listed are based on system software parameter limitations and pathway ODCM release flow rate. In addition, the maximum range is based on a release concentration of 1E-02 uCi/cc, limited by the automatic swap to the high range monitor.

Note: Because actual pathway release flow rate may vary, the "Minimum Instr. Range" and "Maximum Instr. Range" may not reflect the actual instrument ranges. Site dose assessment corrects the uCi/s for source term and flow rate differences depending on selected default source term and decay period. RM-1GW-109 monitors for low range noble gases at the discharge of the Gaseous Waste Disposal Blowers. Provides alarms to warn the operator of abnormal releases and provides input to calculate integrated release data.

BV2 XR014 Date: Changed to "02/02/2015" Unique System Desc.: "Point deleted per ECP 10-0150" Clear all other fields except Date, Reactor Unit, Data Feeder, Point ID

Attachment L-15-247 Summary of Changes to Data Point Library (Page 2 of 2)

Reactor DPL Point Description of Change(s)

Unit BV2 XR015 Date: Changed to "02/02/2015" Plant Spec Point Desc: changed to "IRM-GW-109 HRNGM" Engr Units/Dig States: "CPM" to "uCi/sec" Engr Units Conversion: to "Xe 133 CF = amps/uCi/cc" Minimum Instr Range: changed to "4.3E+01" Maximum Instr Range: changed to "1.8E+11" Alarm/Trip Set Points: changed to "Alert=3.27E+05, High=6.55E+05" Unique System Desc.: changed to 1 minute average data. System design is such that either the RM-1GW-109 low range or high range noble gas monitor for each pathway will be in service. At a concentration of 1E-02 uCi/cc on the low range monitor, flow will normally swap to the high range monitor. Minimum and maximum instrument ranges listed are based on Xe-133 and pathway ODCM release flow rate. Maximum range is based on monitor parameter setting and ODCM release flow rate. Note: Because actual pathway release flow rate may vary, the "Minimum Instr. Range" and "Maximum Instr. Range" may not reflect the actual instrument ranges. Site dose assessment corrects the uCi/s for source term and flow rate differences depending on selected default source term and decay period. RM-1GW-109 monitors for high range noble gases at the discharge of the Auxiliary Building shielded area exhaust fans and at the discharge of the Gaseous Waste Disposal Blower. Site dose assessment corrects the uCi/s for source term and flow rate differences depending on selected default source term and decay period. Provides alarms to warn the operator of abnormal releases and provides input to calculate integrated release data.

Enclosure L-1 5-247 Beaver Valley Power Station ERDS Data Point Library, Updated Pages (3 pages follow)

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

2/2/2015 Reactor Unit:

BV2 Data Feeder:

ARERAS NRC ERDS Parameter:

EXTRAI 5 Point ID:

XR013 Plant Spec Point Desc.:* 1RM-GW-109 LRNGM Generic/Cond Desc.:

RADIOACTIVITY OF RELEASED GASSES Analog/Digital:

A Engr Units/Dig States:

Engr Units Conversion:

uCi/sec Xe 133 CF = cps/uC icc Minimum lnstr.Range:

68E-01 Maximum Instr Range:

6.8E+03 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC orSENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Location:

SEE UNIQUE SYSTEM DESCRIPTION FIELD AlarmTrip Set Points:

normally N/A NI Detector Power Supply Cut-Off Power Level:

N/A NI Detector Power Supply Turn-ON Power Level:

N/A Instrument Failure Mode:

DEPENDS ON FAILUREAMODE Temperature Compensation for DP Transmitters:

N Level Reference Leg:

N/A Unique System Desc.:

1 minute average data. System design is such that either the RM-1GW-109 low range or high range noble gas monitor for each pathway will be in service. At a concentration of 1 E-2 uCi/cc on the low range monitor, flow will normally swap to the high range monitor. The listed minimum and maximum instrument ranges listed are based on system software parameter limitations and pathway ODCM release flow rate. In addition, the maximum range is based on a release concentration of 1 E-2 uCi/cc, limited by the automatic swap to thehigh range monitor. Note Because actual pathway.release~flow rate may vary; the "Minimum Instr Range" and "Maximum Instr Range" may notreflect the actual instrument ranges. Site dose assessment corrects the uCi/s for source term and flow rate differences depending on selected default source term and decay period. RM-1GW-109 monitors for low range noble gases at the discharge of the Gaseous Waste Disposal Blowers. Provides alarms to warn the operator of abnormal releases and provides input to calculate integrated release data.

2-72

Reacto Data F NRC ERDS Paraý PC Plant Spec Point I Generic/Cond I Analog/[

Engr Units/Dig S Engr Units ConvE Minimum Instr R Maximum Instr R Zero Point Refei Reference Point I PROC or,'

Number of Sei How ProcE Sensor Loc Alarm/Trip Set F NI Detector Power Supply Cut-Off Power I NI Detector Power Supply Turn-ON Power!

Instrument Failure I Temperature Compensation for DP Transm Level Referenc(

Unique System I BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

2/2/2015

,rUnit:

BV2 eeder:

ARERAS meter:

int ID:

XR014 Desc.:

Desc.:

)igital:

.tates:

ýrsion:

ange:

ange:

rence:

Notes:

iENS:

nsors:

ýssed:

ation:

oints:

Level:

Level:

Mode:

itters:

? Leg:

)escc:

point deleted per ECP 10-0150 2-73

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

2/2/2015 Reactor Unit:

BV2 Data Feeder:

ARERAS NRC ERDS Parameter:

EXTRA 17 Point ID:

XR01 5 Plant Spec Point Desc.:

Generic/Cond Deso.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

1RM-GW-109 HRNGM RADIOACTIVITY OF RELEASED GASSES A

uCi/sec Xe133 CF = amps/uCVcc Minimum Instr Range:

4.3E+01 Maximum Instr Range:

1,8E+11 Zero Point Reference, N/A Reference Point Notes:

N/A PROC orSENS, S

Number of Sensors:

1 How Processed:

N/A Sensor Location:

SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points:

Alert-3.27E+5, High=6.65E+5 NI Detector Power Supply Cut7-Off Power Level:

N/A NI Detector Power Supply Turn-ON Power Level:

N/A Instrument Failure Mode:

DEPENDS ON FAILURE MODE Temperaturc Compensation for DP Transmitters; N

Level Reference Leg:

N/A Unique System Desc.:

1 minute average data. System design is such that either the RM-1GW-109 low range or high range noble gas monitor for each pathway will be in service. At a concentration of 1 E-2 uCi/cc on the low range monitor, flow will normally swap to the high range monitor. Minimum and maximum instrument ranges listed are based on Xe-133 and pathway ODCM release flow rate.

Maximum range is based on monitor parameter setting and ODCM release flow rate. Note Because actual pathway release flow rate may vary, the "Minimum Instr Range" and "Maximum lnstr Range" may not reflect the actual instrument ranges, Site dose assessment corrects the uCi/s for source term and flow rate differences depending on selected default source term and decay period. RM-1GW-109 monitors for high range noble gases at the discharge of the Auxiliary Building shielded area exhaust fans and at the discharge of the Gaseous Waste Disposal Blower, Site dose assessment corrects the uCi/s for source term and flow rate differences depending on selected default source term and decay period. Provides alarms to warn the operator of abnormal releases and provides input to calculate integrated release dnta 2-74