Text
FEN C FirstEnergy Nuclear Operating Company Paul A. Harden Site Vice President Beaver Valley Power Station P.O. Box 4 Shippingport, PA 15077 724-682-5234 Fax: 724-643-8069 November 22, 2011 L-11-352 10 CFR 50, Appendix E, Section VI ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001
SUBJECT:
Beaver Valley Power Station, Unit Nos. 1 and 2 Docket No. 50-334, License No. DPR-66 Docket No. 50-412, License No. NPF-73 Emergency Response Data System Data Point Library Update In accordance with 10 CFR 50, Appendix E, Section VI, an update of the Emergency Response Data System (ERDS) Data Point Library (DPL) for Beaver Valley Power Station, Unit Nos. 1 (BV1) and 2 (BV2) is provided. An attachment provides the details regarding each change and copies of updated DPL pages are enclosed.
There are no regulatory commitments contained in this letter. If there are any questions or if additional information is required, please contact Mr. Phil H. Lashley, Supervisor-Fleet Licensing, at (330) 315-6808.
j/;;:/ r /1 Sin.c.. e~~e~
/~P ~-
Paul A. Harden
Attachment:
Summary of Changes to Data Point Library
Enclosure:
Beaver Valley Power Station ERDS Data Point Library, Updated Pages cc:
NRC Region I Administrator NRC Resident Inspector NRC Project Manager (w/o enclosures)
Director BRPIDEP Site BRPIDEP Representative
Reactor DPL Unit Point BV1 XM006 BV1 XM026 BV2 XM006 BV2 XM026 Attachment L-11-352 Summary of Changes to Data Point Library Page 1 of 1 Description of Change(s)
Maximum Instr Range: changed from "50" to "100" Maximum Instr Range: changed from "50" to "100" Maximum Instr Range: changed from "50" to "100" Maximum Instr Range: changed from "50" to "100"
Enclosure L-11-352 Beaver Valley Power Station EROS Data Point Library, Updated Pages (4 pages follow)
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
11/3/2011 Reactor Unit:
BV1 Data Feeder:
ARERAS NRC ERDS Parameter:
WIND-SPEED1 Point ID:
XM006 Plant Spec Point Desc.:
WIND SPEED 35' ELEVATION Generic/Cond Desc.:
WIND SPEED AT THE REACTOR SITE Analog/Digital:
A Engr Units/Dig States:
MPH Engr Units Conversion:
N/A Minimum Instr Range:
0 Maximum Instr Range:
100 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
2 How Processed:
FAILOVER SUBSTITUTION Sensor Location:
SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points:
N/A NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-ON Power Level:
N/A Instrument Failure Mode:
DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.:
Point is the 15 minute average value for primary sensor. Redundant sensor value substituted if primary bad or missing. Sensors are same quality/calibration. Value used in dose assessments, as ground level speed.
Ref: Calculation Package ERS-SFL-92-024; CR 04-05484 1-68
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
11/3/2011 Reactor Unit:
BV1 Data Feeder:
ARERAS NRC ERDS Parameter:
WIND-SPEED2 Point ID:
XM026 Plant Spec Point Desc.:
WIND SPEED 500' ELEVATION Generic/Cond Desc.:
WIND SPEED AT THE REACTOR SITE Analog/Digital:
A Engr Units/Dig States:
MPH Engr Units Conversion:
N/A Minimum Instr Range:
0 Maximum Instr Range:
100 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
2 How Processed:
FAILOVER SUBSTITUTION Sensor Location:
SEE UNIQUE SYSTEM DESCRIPTION FIELD AlarmlTrip Set Points:
N/A NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-ON Power Level:
N/A Instrument Failure Mode:
DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.:
Point is the 15 minute average value for primary sensor. Redundant sensor substituted if primary bad or missing. Sensors are same quality/calibration.
Value is dose assessments as elevated wind speed. Ref: Calculation Package ERS-SFL-92-024; CR 04-05484 1-69
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
11/3/2011 Reactor Unit:
BV2 Data Feeder:
ARERAS NRC ERDS Parameter:
WIND-SPEED1 Point ID:
XM006 Plant Spec Point Desc.:
WIND SPEED 35' ELEVATION Generic/Cond Desc.:
WIND SPEED AT THE REACTOR SITE Analog/Digital:
A Engr Units/Dig States:
MPH Engr Units Conversion:
N/A Minimum Instr Range:
0 Maximum Instr Range:
100 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
2 How Processed:
FAILOVER SUBSTITUTION Sensor Location:
SEE UNIQUE SYSTEM DESCRIPTION FIELD AlarmlTrip Set Points:
N/A NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-ON Power Level:
N/A Instrument Failure Mode:
DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.:
Point is the 15 minute average value for primary sensor. Redundant sensor value substituted if primary bad or missing. Sensors are same quality/calibration. Value used in dose assessments, as ground level speed.
Ref: Calculation Package ERS-SFL-92-024; CR 04-05484 2-66
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
11/3/2011 Reactor Unit:
BV2 Data Feeder:
ARERAS NRC ERDS Parameter:
WIND-SPEED2 Point ID:
XM026 Plant Spec Point Desc.:
WIND SPEED 500' ELEVATION Generic/Cond Desc.:
WIND SPEED AT THE REACTOR SITE Analog/Digital:
A Engr Units/Dig States:
MPH Engr Units Conversion:
N/A Minimum Instr Range:
0 Maximum Instr Range:
100 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number of Sensors:
2 How Processed:
FAILOVER SUBSTITUTION Sensor Location:
SEE UNIQUE SYSTEM DESCRIPTION FIELD AlarmlTrip Set Points:
N/A NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-ON Power Level:
N/A Instrument Failure Mode:
DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.:
Point is the 15 minute average value for primary sensor. Redundant sensor substituted if primary bad or missing. Sensors are same quality/calibration.
Value is dose assessments as elevated wind speed. Ref: Calculation Package ERS-SFL-92-024; CR 04-05484 2-67