L-11-090, Supplemental Information Related to Modification of Technical Specification 2.1.1, Reactor Core Sls

From kanterella
(Redirected from L-11-090)
Jump to navigation Jump to search

Supplemental Information Related to Modification of Technical Specification 2.1.1, Reactor Core Sls
ML110880095
Person / Time
Site: Perry FirstEnergy icon.png
Issue date: 03/17/2011
From: Hanson H
FirstEnergy Nuclear Operating Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-11-090, TAC ME4925
Download: ML110880095 (2)


Text

FENOC Perry Nuclear Power Plant 10 Center Road FirstEnergy Nuclear Operating Company P0. Box 97 Perry, Ohio 44081 March.17, 2011 L-1 1-090 10 CFR 50.90 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

SUBJECT:

Perry Nuclear Power Plant Docket No. 50-440, License No. NPF-58 Supplemental Information Related to Modification of Technical Specification 2.1.1, "Reactor Core SLs" (TAC NO. ME4925)

By letter dated October 21, 2010 (Accession No. ML102980451) and supplemented by letter dated February 2, 2011 (Accession No. ML110400136), FirstEnergy Nuclear Operating Company (FENOC) submitted to the Nuclear Regulatory Commission (NRC) a license amendment request for the Perry Nuclear Power Plant (PNPP). The proposed amendment would incorporate revised safety limit minimum critical power ratio (SLMCPR) values into the PNPP Technical Specifications.

On March 3, 2011, a teleconference conducted between the NRC and the FENOC staffs discussed the response to RAI lb contained in the February 2, 2011 letter.

Based upon the teleconference, the following supplemental information is provided.

For Table RAI-01-3, "Bundle group, Number of bundles, type, % [percent]

contribution to NRSBT [number of rods subject to boiling transition], and group exposure for TLO [two-loop operation]," the core average exposure for the limiting time in core life for TLO (near beginning of cycle) is 16.61 gigawatt-days/short ton (GWd/ST). For Table RAI-01-4, "Bundle group, Number of bundles, type, %

[percent] contribution to NRSBT [number of rods subject to boiling transition], and group exposure for SLO [single loop operation]," the core average exposure for the limiting time in core life for SLO (near end of cycle)- is 29.41 GWd/ST.

74c

Perry Nuclear Power Plant L-1 1-090 Page 2 of 2 There are no regulatory commitments contained in this submittal. If there are any questions or if additional information is required, please contact Mr. Thomas A. Lentz, Manager - Fleet Licensing, at (330) 761-6071.

I declare under penalty of perjury that the foregoing is true and correct. Executed on March /L__,

2011.

cc:

NRC Region III Administrator NRC Project Manager NRC Resident Inspector Executive Director, Ohio Emergency Management Agency, State of Ohio (NRC Liaison)

Utility Radiological Safety Board