L-08-025, Emergency Response Data System
| ML080250045 | |
| Person / Time | |
|---|---|
| Site: | Beaver Valley (NPF-073) |
| Issue date: | 01/23/2008 |
| From: | Sena P FirstEnergy Nuclear Operating Co |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| L-08-025 | |
| Download: ML080250045 (5) | |
Text
FENOC FirstEnergy Nuclear Operating Company Peter P. Sena III 724-682-5234 Site Vice President Fax: 724-643-8069 January 23, 2008 10 CFR 50, Appendix E,Section VI L-08-025 ATTN: Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555-0001
Subject:
Beaver Valley Power Station, Unit No. 2 BV-2 Docket No. 50-412, License No. NPF-73 Emergency Response Data System In accordance with 10 CFR 50, Appendix E,Section VI, revisions to the Beaver Valley Power Station (BVPS) Unit No. 2 Data Point Library (DPL) for the Emergency Response Data System (ERDS) are enclosed. The DPL changes are associated with the increasing of the high alarm setpoints of the Intermediate Range Detectors (Point IDs N0035A and N0036A). The Attachment provides a summary of the changes made for these data points.
There are no regulatory commitments contained in this letter. If there are any questions or if additional information is required, please contact Mr. Thomas A. Lentz, Manager-FENOC Fleet Licensing, at 330-761-6071.
Sincerely, Peter P. Sena III Attachment - Summary Of Changes To Data Point Library Enclosure - Revised pages to the Data Point Library c:
Ms. N. S. Morgan, NRR Project Manager (w/o enclosure)
Mr. D. L. Werkheiser, NRC Senior Resident Inspector Mr. S. J. Collins, NRC Region I Administrator Mr. D. J. Allard, Director BRP/DEP 4 aO.2 Mr. L. E. Ryan (BRP/DEP)
ATTACHMENT L-08-025
SUMMARY
OF CHANGES TO DATA POINT LIBRARY (DPL)
Page 1 of 1 Reactor DPL Description of Change(s)
Unit Point BV2 N0035A Date: Changed to "1/7/2008" Alarm/Trip Set Points:: Replaced "8.5E-04" with "HI = 9.5E-04" N0036A Date: Changed to "1/7/2008" Alarm/Trip Set Points:: Replaced "8.5E-04" with "HI = 9.5E-04"
ENCLOSURE L-08-025 REVISED PAGES TO BEAVER VALLEY POWER STATION UNIT 2, DATA POINT LIBRARY (2 Pages)
I
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
1/7/2008 BV2 PCS NI-INTER-RNG N0035A INT RNG DET 1 FLUX-LOG NM35B NUCLEAR INSTRUMENTS, INT RANGE A
AMP EU=eA[(3.684138E-03 *mv)+(-2.532840E+01) 1 E-11 1 E-3 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HI =9.5E-04 2/4 PWRRNG >10%
3/4 PWRRNG <10%
LOW N
N/A Intermediate Range level indication from 1.0E-11 to 1.OE-3 Amps corresponds to about 1OE-6% to 10E2% full rated power. Power Range level indication will not come on scale until the Reactor power rises to about 10E-5 Amps Intermediate Range level (- 1% full power). 2NMI-NE35 (see attached NIS detector location dwg). Ref: Op Manual Chapter 2; 10080-TLD-02-003.
A I BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
1/7/2008 BV2 PCS EXTRA4 N0036A INT RNG DET 2 FLUX-LOG NM36B NUCLEAR INSTRUMENTS, INT RANGE A
AMP EU=eA[(3.684138E-03 *mv)+(-2.532840E+01) 1E-11 1 E-3 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HI = 9.5E-04 2/4 PWRRNG >10%
3/4 PWRRNG <10%
LOW N
N/A Intermediate Range level indication from 1.OE-11 to 1.OE-3 Amps corresponds to about 1OE-6% to 10E2% full rated power. Power Range level indication will not come on scale until the Reactor power rises to about 10E-5 Amps Intermediate Range level (- 1% full power). 2NMI-NE36 (see attached NIS detector location dwg). Ref: Op Manual Chapter 2; 10080-TLD-02-004.