Beaver Valley Power Station.

FENOCRoute 168 P.O. Box 4 FirstErnery Nuc~lear Ooe~ratie~gCompan '

Shippingport, PA 15077-0004 L-07-110 August 8, 2007 Ms. Kareen Milcic Permits Chief Water Management Program Southwest Region Pennsylvania Department of Environmental Protection 400 Waterfront Drive Pittsburgh, PA.15222-4745 Renewal Application for Beaver Valley Power Station NPDES Outfall 012 NPDES Permit No. PA0025615

Dear Ms. Milcic:

Enclosed please find three copies of the Pennsylvania Department of Environmental Protection (DEP)

NPDES Permit renewal application for First Energy Nuclear Operating Company (FENOC) Beaver Valley Power Station NPDES Outfall 012. The evaporative coolers serving the HVAC unit for the Emergency Response Facility were replaced in December of 2006. Sampling was completed in January of 2007. This should complete our application package.

Should you have any questions regarding the attached documents, please direct them to Mr. Michael Banko, at 724-682-4117.

Sincerely, Kevin L. Ostrowski Director, Site Operations Enclosures cc:

US Nuclear Regulatory Commission (Note: No new NRC commitments are contained in this submittal.)

Cool

3800-PM-WSFR0008h Rev. 3/2006 Module 5 Applicant Name: FirstEnergy Nuclear Operating Company (FENOC)

Beaver Valley Power Station COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF WATER STANDARDS AND FACILITY REGULATION ANALYSIS RESULTS TABLE POLLUTANT GROUP 2 MODULE 5 Before completing this form, read the step-by-step instructions provided in Appendix 1.

APPLICANT NAME.

FirstEnergy Nuclear Operating Company - Beaver Valley Power Station Z

Outfall Number Outfall 012 (Show location of sampling point on Line Drawing)

W Intake Sampling Results - Optional (Specify Source:

.)

E]

Background Sampling Results - Optional (Specify Location: __

)

F] Treatment Facility Influent Sampling Results (Show location of sampling point on Line Drawing)

LI New Discharge (Basis for Information: __

)

El Bypass or Sewer System Overflow (Describe: __

)

3. Level Present POLLUTANT GROUP 2
2. EPA
5. Coefficient
1. MDL Method
a. Max Daily Value
b. Average of Analysis
c.
4. Units of Effluent Metals Used*

Number Number of Variability (pg/L)

Used Concentration Mass Concentration Mass Analysis Concentration Mass (CV)

I M Antimony, Total 2

200.7 15 0.0001 1

ug/I lb/day 2M Arsenic, Total 10 200.7 14

.0.0001 1

ug/I lb/day 3M Beryllium, Total 2

200.7 2

0.00002 1

ug/I lb/day 4M Cadmium, Total 2

200.7 ND 1

ug/I lb/day 5M Chromium I1l 2

200.7 30 0.0003 6

0.0001 6

ug/i lb/day 5M Chromium VI 10 218.4 ND 1

ug/I lb/day 6M Copper, Total 2

200.7 135 0.0011 57 0.0005 7

ug/I lb/day 7M Lead, Total 2

200.7 ND 1

ug/I lb/day 8M Mercury, Total 0.2 245.2 ND 1

ug/I lb/day 9M Nickel, Total 5

200.7 ND 1

ug/I lb/day 10M Selenium, Total 8

200.7 ND 1

ug/I lb/day 11M

-Silver, Total 1

200.7 8

0.0001 1

ug/I lb/day 3.

3.a.

3.b.

3.c.

If other data is available (i.e., DMR data, etc.), the past year of data may be used to determine 3a, 3b, 3c, and 5.

Maximum Daily Value - Report the highest daily value or daily average value from the last year of data. Report both mass and concentration.

Average of Analysis - Determine the average of all samples taken within the past year. Report both mass and concentration.

A minimum of 3 Sampling Events required for process wastewater discharges, and a minimum of 1 Sampling Event for all other discharges, treatment facility influent, intake water and background.

It is in the applicant's interest to achieve the lowest level of detection possible. This will minimize uncertainty and therefore the need for additional analysis or potential for establishing a large number of effluent limits and/or monitoring requirements in the final NPDES permit.

3800-PM-WSFRO008h Rev. 3/2006 Module 5 Applicant Name: FirstEnergy Nuclear Operating Company (FENOC)

Beaver Valley Power Station

3. Level Present POLLUTANT GROUP 2
5. Coefficient
1. MDL
2. EPA
a. Max Daily Value
b. Average of Analysis
c.
4. Units of Effluent Metals Used*

Method Number of Variability (pg/L)

Number Used Concentration Mass Concentration Mass Analysis Concentration Mass (CV) 12M Thallium, Total 10 200.7 ND 1

ug/I lb/day 13M Zinc, Total 8

200.7 408 0.0034 148 0.0012 7

ug/I lb/day 14M Cyanide, Total 14M Cyanide, Free 15M Phenols, Total 3.

3.a.

3.b.

3.c.

If other data is available (i.e., DMR data, etc.), the past year of data may be used to determine 3a, 3b, 3c, and 5.

Maximum Daily Value - Report the highest daily value or daily average value from the last year of data. Report both mass and concentration.

Average of Analysis - Determine the average of all samples taken within the past year. Report both mass and concentration.

A minimum of 3 Sampling Events required for process wastewater discharges, and a minimum of 1 Sampling Event for all other discharges, treatment facility influent,'intake water and background.

It is in the applicant's interest to achieve the lowest level of detection possible. This will minimize uncertainty and therefore the need for additional analysis or potential for establishing a large number of effluent limits and/or monitoring requirements in the final NPDES permit.

3800-PM-WSFROO08g Rev. 3/2006 Module 4 Po"~ep Applicant Name: FirstEnergy Nuclear Operating Company (FENOC) -

Beaver Valley Power Station Outfall: 012 COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF WATER STANDARDS AND FACILITY REGULATION ANALYSIS RESULTS TABLE POLLUTANT GROUP 1 MODULE 4 Before completing this form, read the step-by-step instructions provided in Appendix 1.

iAPPLICANT NAME FirstEnergy Nuclear Operating Company (FENOC) - Beaver Valley Power Station Z

Outfall Number 012 (Show location of sampling point on Line Drawing)

El Intake Sampling Results - Optional (Specify Source: __)

El Background Sampling Results - Optional (Specify Location of Sample: I.

El Treatment Facility Influent Sampling Results (Show location of sampling point on Line Drawing)

[

New Discharge (Basis for Information: ___)

El Bypass or Sewer System Overflow (Describe: __)

1. LEVEL PRESENT
2. UNITS 3.

Coefficient POLLUTANT GROUP 1

a. Maximum Daily Value
b. Average of Analysis of Effluent
c. No. of
a.

Variability (1) Concentration (2) Mass (1) Concentration (2) Mass Analysis Concentration

b. Mass (CV)

Biochemical Oxygen Demand, BOD 14 0.117 1

mg/I lb/day Chemical Oxygen Demand, COD

<20 1

mg/I lb/day Hardness (CaCO3) 240 2.00 1

CaCO3 lb/day Total Suspended Solids, TSS

<4 1

mg/I lb/day Total Dissolved Solids, TDS 512 4.27 461 3.84 6

mg/I lb/day Ammonia as N

<0.1 1

mg/I lb/day Nitrate-Nitrite (as N) 3.00 0.025 1

mg/I lb/day Total Kjeldahl Nitrogen (TKN) 0.416 0.003 1

mg/I lb/day Phosphorus (as P), Total

<0.05 1

mg/I lb/day Temperature winter 17.9 Value Value 1

C Temperature summer Value Value 1

C pH Mi.

7.75 Max.

8.56 7

Standard units Standard units Standard units 1.a.

l.b.

1.c.

Maximum Daily Value - Report the highest daily value or daily average value from the last year of data. Report both mass and concentration.

Average of Analysis - The average of all values within the last year and report both the mass and concentration.

A minimum of 3 Sampling Events required for process wastewater discharges, and a minimum of 1 Sampling Event for all other discharges, treatment facility influent, intake water and background.

3800-PM-WSFROO08g Rev. 3/2006 Module 4 Applicant Name: FirstEnergy Nuclear Operating Company (FENOC) -

Beaver Valley Power Station Outfall: 012

3. Level Present
2. EPA
5. Coefficient POLLUTANT GROUP 1
1. MDL Method
a. Max Daily Value
b. Average of Analysis
c.
4. Units of Effluent Believed Used*

Number Number of Variability Absent (pg/L)

Used Concentration Mass Concentration Mass Analysis Concentration Mass (CV)

Cotor 25 1`10.2 ND 1

Units Fecal Coliform 2

SM9222 D ND 1

counts/100ml Fluoride El 40 340.2 0.3 0.003 1

mg/i lb/day Oil and Grease 5000 1664A ND 1

mg/I lb/day Bromide 50 300 ND 1

mg/L lb/day Chlorine, Total Residual 0.05 330.5 ND 1

mg/L lb/day Sulfate

[]

100 300 109 0.909 1

mg/I lb/day Sulfide 2000 9030A ND 1

mg/I lb/day Sulfite 2000 377.1 ND 1

mg/I lb/day Surfactants 0.1 5540C ND 1

mg/I lb/day Aluminum, Total 4

200.7 36 0.0003 1

ug/I lb/day Barium, Total 15 200.7 63 0.0005 1

ug/I lb/day Boron, Total 50 212.3 73 0.0006 1

ug/I lb/day Cobalt, Total 2

200.7 13 0.0001 1

ug/I lb/day Iron, Total 2

200.7 50 0.0004 1

ug/I lb/day Iron, Dissolved 2

200.7 16 0.0001 1

ug/l lb/day Manganese, Total 1-1 4

200.7 14 0.0001 1

ug/I lb/day Radioactivity (Total Alpha and Beta)

[]

1.0 900.0 2.9 1

pCi/L Total Organic Carbon, TOC Ej 1000 9060

<1 1

mg/I lb/day Radium, Total 1.8 903.1 &

ND 1

pCi/L Ra-05 Magnesium 30 200.7 17100 0.143 1

ug/l lb/day Molybdenum 10 200.7 16

.0.0001 1

ug/I lb/day Tin, Total 80 200.7 ND 1

ug/I lb/day Titanium, Total 2

200.7 3

0.00003 1

ug/I lb/day 3.

3.a.

3.b.

3.c.

If other data is available (i.e., DMR data, etc.), the past year of data may be used to determine 3a, 3b, 3c, and 5.

Maximum Daily Value - Report the highest daily value or daily average value from the last year of data. Report both mass and concentration.

Average of Analysis - Determine the average of all samples taken within the past year. Report both mass and concentration.

A minimum of 3 Sampling Events required for process wastewater discharges, and a minimum of 1 Sampling Event for all other discharges, treatment facility influent, intake water and background.

It is in the applicant's interest to achieve the lowest level of detection possible. This will minimize uncertainty and therefore the need for additional analysis or potential for establishing a large number of effluent limits and/or monitoring requirements in the final NPDES permit.