MONTHYEARL-23-267, Submittal of Discharge Monitoring Report (Npdes), Permit No. PA00256152023-12-18018 December 2023 Submittal of Discharge Monitoring Report (Npdes), Permit No. PA0025615 L-23-229, Request for Additional Information Regarding the Spring 2023 Generic Letter 95-05 Voltage-Based Alternate Repair Criteria and Steam Generator F-Star Reports2023-11-29029 November 2023 Request for Additional Information Regarding the Spring 2023 Generic Letter 95-05 Voltage-Based Alternate Repair Criteria and Steam Generator F-Star Reports L-23-247, Discharge Monitoring Report (NPDES) Permit No. PA00256152023-11-17017 November 2023 Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-23-227, Discharge Monitoring Report (NPDES) Permit No. PA0025615 for Third Quarter 20232023-10-20020 October 2023 Discharge Monitoring Report (NPDES) Permit No. PA0025615 for Third Quarter 2023 L-23-208, Submittal of Discharge Monitoring Report Cnpdes), Permit No. PA00256152023-09-14014 September 2023 Submittal of Discharge Monitoring Report Cnpdes), Permit No. PA0025615 L-23-167, Twenty-Third Refueling Outage Inservice Inspection Summary Report2023-09-13013 September 2023 Twenty-Third Refueling Outage Inservice Inspection Summary Report L-23-205, Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments2023-09-12012 September 2023 Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments L-23-172, Quality Assurance Program Manual2023-08-31031 August 2023 Quality Assurance Program Manual L-23-188, Energy Harbor Nuclear Corp., Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments2023-08-0707 August 2023 Energy Harbor Nuclear Corp., Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments L-23-179, Submittal of Discharge Monitoring Report, (NPDES) Permit No. PA00256152023-07-18018 July 2023 Submittal of Discharge Monitoring Report, (NPDES) Permit No. PA0025615 L-23-165, Discharge Monitoring Report (NPDES) Permit No. PA00256152023-06-26026 June 2023 Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-23-139, Response to Request for Additional Information Regarding Fall 2022 180-Day Steam Generator Tube Inspection Report2023-06-13013 June 2023 Response to Request for Additional Information Regarding Fall 2022 180-Day Steam Generator Tube Inspection Report L-23-055, Submittal of the Updated Final Safety Analysis Report, Revision 342023-05-23023 May 2023 Submittal of the Updated Final Safety Analysis Report, Revision 34 L-23-065, Annual Financial Report2023-05-22022 May 2023 Annual Financial Report L-23-137, Discharge Monitoring Report (NPDES) Permit No. PA00256152023-05-18018 May 2023 Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-23-125, Cycle 24 Core Operating Limits Report2023-05-17017 May 2023 Cycle 24 Core Operating Limits Report L-23-132, Response to NRC Regulatory Issue Summary 2023-01 Preparation and Scheduling of Operator Licensing Examinations2023-05-10010 May 2023 Response to NRC Regulatory Issue Summary 2023-01 Preparation and Scheduling of Operator Licensing Examinations L-23-129, Response to Request for Additional Information for 10 CFR 50.55a Request 2-TYP-4-RV-06 for Alternative Repair Methods for Reactor Pressure Vessel Head Penetrations2023-05-0505 May 2023 Response to Request for Additional Information for 10 CFR 50.55a Request 2-TYP-4-RV-06 for Alternative Repair Methods for Reactor Pressure Vessel Head Penetrations L-23-115, Submittal of 2022 Annual Radioactive Effluent Release Report, 2022 Annual Radiological Environmental Operating Report, and 2022 Annual Environmental Operating Report (Non-Radiological2023-04-27027 April 2023 Submittal of 2022 Annual Radioactive Effluent Release Report, 2022 Annual Radiological Environmental Operating Report, and 2022 Annual Environmental Operating Report (Non-Radiological L-23-126, Discharge Monitoring Report (Npdes), Permit No. PA00256152023-04-22022 April 2023 Discharge Monitoring Report (Npdes), Permit No. PA0025615 L-23-053, 2022 Annual 10 CFR 50.46 Report of Changes to or Errors in Emergency Core Cooling System Evaluation Models2023-04-14014 April 2023 2022 Annual 10 CFR 50.46 Report of Changes to or Errors in Emergency Core Cooling System Evaluation Models L-23-061, Submittal of the Decommissioning Funding Status Reports2023-03-31031 March 2023 Submittal of the Decommissioning Funding Status Reports L-23-058, 180-Day Steam Generator Tube Inspection Report2023-03-27027 March 2023 180-Day Steam Generator Tube Inspection Report L-23-066, Annual Notification of Property Insurance Coverage2023-03-21021 March 2023 Annual Notification of Property Insurance Coverage L-23-036, Report of Facility Changes, Tests and Experiments2023-03-13013 March 2023 Report of Facility Changes, Tests and Experiments L-23-086, Response to Request for Additional Information for Emergency License Amendment Request for Technical Specification 3.5.2 Regarding One-Time Action for Valve Leak Repair2023-03-0404 March 2023 Response to Request for Additional Information for Emergency License Amendment Request for Technical Specification 3.5.2 Regarding One-Time Action for Valve Leak Repair L-23-087, Supplement to Emergency License Amendment Request for Technical Specification 3.5.2 Regarding One-Time Action for Valve Leak Repair (L-2023-LLA-0027)2023-03-0404 March 2023 Supplement to Emergency License Amendment Request for Technical Specification 3.5.2 Regarding One-Time Action for Valve Leak Repair (L-2023-LLA-0027) L-23-073, Emergency License Amendment Request for Technical Specification 3.5.2 Regarding One-Time Action for Valve Leak Repair2023-03-0101 March 2023 Emergency License Amendment Request for Technical Specification 3.5.2 Regarding One-Time Action for Valve Leak Repair L-23-016, Twenty-Eighth Refueling Outage Inservice Inspection Summary Report2023-02-21021 February 2023 Twenty-Eighth Refueling Outage Inservice Inspection Summary Report L-23-064, Discharge Monitoring Report, (NPDES) Permit No. PA00256152023-02-21021 February 2023 Discharge Monitoring Report, (NPDES) Permit No. PA0025615 L-23-057, Energy Harbor Nuclear Corp Retrospective Premium Guarantee2023-02-20020 February 2023 Energy Harbor Nuclear Corp Retrospective Premium Guarantee L-22-193, Request for Exemption from Specific Provisions in 10 CFR 50 Appendix H2023-02-14014 February 2023 Request for Exemption from Specific Provisions in 10 CFR 50 Appendix H L-22-286, Supplement to Request for an Amendment to Consolidate Fuel Decay Time Technical Specifications in a New Limiting Condition for Operation Titled Decay Time2023-02-14014 February 2023 Supplement to Request for an Amendment to Consolidate Fuel Decay Time Technical Specifications in a New Limiting Condition for Operation Titled Decay Time L-23-032, Discharge Monitoring Report (NPDES) Permit No. PA0025615 for Second Half of 20222023-01-23023 January 2023 Discharge Monitoring Report (NPDES) Permit No. PA0025615 for Second Half of 2022 L-22-281, Discharge Monitoring Report (NPDES) Permit No. PA00256152022-12-16016 December 2022 Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-22-246, Response to Request for Additional Information Regarding a Request to Consolidate Fuel Decay Time Technical Specifications to New LCO2022-12-0707 December 2022 Response to Request for Additional Information Regarding a Request to Consolidate Fuel Decay Time Technical Specifications to New LCO L-22-217, Submittal of Discharge Monitoring Report (NPDES) Permit No. PA00256152022-11-21021 November 2022 Submittal of Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-22-226, Emergency Preparedness Plan2022-11-0404 November 2022 Emergency Preparedness Plan L-22-222, Cycle 29-1 Core Operating Limits Report2022-10-31031 October 2022 Cycle 29-1 Core Operating Limits Report L-22-228, Independent Spent Fuel Storage Installation Changes, Tests, and Experiments2022-10-26026 October 2022 Independent Spent Fuel Storage Installation Changes, Tests, and Experiments L-22-200, Response to Request for Additional Information Regarding a 180-Day Steam Generator Tube Inspection Report Fall 2021 Refueling Outage2022-10-21021 October 2022 Response to Request for Additional Information Regarding a 180-Day Steam Generator Tube Inspection Report Fall 2021 Refueling Outage L-22-232, Withdrawal of a License Amendment Request Associated with Fire Protection Program Changes2022-10-21021 October 2022 Withdrawal of a License Amendment Request Associated with Fire Protection Program Changes L-22-238, Submittal of Discharge Monitoring Report (NPDES) Permit No. PA00256152022-10-20020 October 2022 Submittal of Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-22-227, Revised August 2022 Outfall 003 & 004 NPDES Discharge Monitoring Report (Dmr), Revised Daily Effluent Monitoring Report Forms for Outfalls 003 & 004 and Corrective Action Letter from Eurofins2022-10-0303 October 2022 Revised August 2022 Outfall 003 & 004 NPDES Discharge Monitoring Report (Dmr), Revised Daily Effluent Monitoring Report Forms for Outfalls 003 & 004 and Corrective Action Letter from Eurofins L-22-219, Submittal of Discharge Monitoring Report (NPDES) Permit No. PA00256152022-09-26026 September 2022 Submittal of Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-22-204, Submittal of Evacuation Time Estimates2022-09-0707 September 2022 Submittal of Evacuation Time Estimates L-22-137, Request for Fire Protection Program Changes2022-09-0606 September 2022 Request for Fire Protection Program Changes L-21-238, License Amendment Request for Addition of Analytical Methodology to the Core Operating Limits Report for a Full Spectrum Loss of Coolant Accident2022-08-31031 August 2022 License Amendment Request for Addition of Analytical Methodology to the Core Operating Limits Report for a Full Spectrum Loss of Coolant Accident L-22-188, Response to Request for Additional Information Regarding Steam Generator Inspection Report- Fall 2021 Refueling Outage2022-08-22022 August 2022 Response to Request for Additional Information Regarding Steam Generator Inspection Report- Fall 2021 Refueling Outage L-22-191, Spent Fuel Storage Cask Registration2022-08-17017 August 2022 Spent Fuel Storage Cask Registration 2023-09-14
[Table view] |
Text
FENO~C Beaver Valley Power Station FirstEnergy Nuclear Operating Company RouAe0708 Shippingport, PA 15077-0004 L William Pearce 724-682-5234 Site Vice President Fax: 724-643-8069 March 22, 2004 L-04-042 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555-0001
Subject:
Beaver Valley Power Station, Unit No. 1 and No. 2 BV-1 Docket No. 50-334, License No. DPR-66 BV-2 Docket No. 50-412, License No. NPF-73 Revised Commitment for the 180-Day Response to Generic Letter 2003-01 By letter L-03-192, dated December 5, 2003, FirstEnergy Nuclear Operating Company (FENOC) provided the Beaver Valley Power Station (BVPS) Unit 1 and 2 response to NRC Generic Letter 2003-01 "Control Room Habitability" dated June 12, 2003. In this letter, FENOC committed to "submit a License Amendment Request to propose revisions to the Technical Specification surveillance requirements on both BVPS units to utilize a more direct measurement method (i.e., leak rate test) to verify Control Room Envelope integrity and a periodic verification that a positive pressure is maintained between the Control Room Envelope and adjacent areas with the Control Room Emergency Ventilation System in operation." The due date provided for this commitment was "within 180 days of the submittal date of this response to Generic Letter 2003-01."
The time frame for the aforementioned commitment was established with the presumption that Industry/Technical Specification Task Force (TSTF) Standard Technical Specification change TSTF-448, Revision 1, Control Room Habitability, dated August 18, 2003, was to be approved by the NRC, well prior to the 180 day commitment due date. This would have allowed sufficient time for FENOC to adequately develop the proposed license amendment request. However, the NRC issued additional questions to the industry to support their review of TSTF-448, Revision 1, on December 16, 2003.
The industry responses to the NRC questions were provided on March 8, 2004.
With the time frame for NRC approval of TSTF-448 remaining uncertain, FENOC is hereby revising the due date for the commitment contained in FENOC Letter L-03-192, as described above, to be performed "within 180 days of NRC approval of TSTF-448."
This revised due date will allow FENOC to develop a license amendment request based upon an NRC approved version of TSTF-448 and will also avoid causing FENOC and the NRC to expend additional resources addressing future potentially unresolved industry 41Db
Beaver Valley Power Station, Unit No. 1 and No. 2 Revised Commitment for the 180-Day Response to Generic Letter 2003-01 L-04-042 Page 2 generic issues associated with this topic on a plant-specific basis. Attachment 1 provides a list of the commitments made in this letter, the commitment made in this letter supercedes the previous commitment made in FENOC letter L-03-192 as discussed above.
If you have questions or require additional information, please contact Mr. Larry R.
Freeland, Manager, Regulatory Affairs/Performance Improvement at 724-682-5284.
Sincerely, Willia earce Attachment c: Mr. T. G. Colburn, NRR Senior Project Manager Mr. P. C. Cataldo, NRC Sr. Resident Inspector Mr. H. J. Miller, NRC Region I Administrator
ATTACHMENT 1 Commitment List The following list identifies those actions committed to by FirstEnergy Nuclear Operating Company (FENOC) for Beaver Valley Power Station (BVPS) Unit Nos. 1 and 2 in this document. This commitment supercedes the previous commitment made in FENOC Letter L-03-192, dated December 5, 2003. Any other actions discussed in the submittal represent intended or planned actions by Beaver Valley. These other actions are described only as information and are not regulatory commitments. Please notify Mr. Larry R. Freeland, Manager, Regulatory Affairs/Performance Improvement, at Beaver Valley on (724) 682-5284 of any questions regarding this document or associated regulatory commitments.
Commitment Due Date Submit a License Amendment Request to propose Within 180 days of NRC revisions to the Technical Specification surveillance approval of TSTF-448 requirements on both BVPS units to utilize a more direct measurement method (i.e., leak rate test) to verify Control Room Envelope integrity and a periodic verification that a positive pressure is maintained between the Control Room Envelope and adjacent areas with the Control Room Emergency Ventilation System in operation.
Text
FENO~C Beaver Valley Power Station FirstEnergy Nuclear Operating Company RouAe0708 Shippingport, PA 15077-0004 L William Pearce 724-682-5234 Site Vice President Fax: 724-643-8069 March 22, 2004 L-04-042 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555-0001
Subject:
Beaver Valley Power Station, Unit No. 1 and No. 2 BV-1 Docket No. 50-334, License No. DPR-66 BV-2 Docket No. 50-412, License No. NPF-73 Revised Commitment for the 180-Day Response to Generic Letter 2003-01 By letter L-03-192, dated December 5, 2003, FirstEnergy Nuclear Operating Company (FENOC) provided the Beaver Valley Power Station (BVPS) Unit 1 and 2 response to NRC Generic Letter 2003-01 "Control Room Habitability" dated June 12, 2003. In this letter, FENOC committed to "submit a License Amendment Request to propose revisions to the Technical Specification surveillance requirements on both BVPS units to utilize a more direct measurement method (i.e., leak rate test) to verify Control Room Envelope integrity and a periodic verification that a positive pressure is maintained between the Control Room Envelope and adjacent areas with the Control Room Emergency Ventilation System in operation." The due date provided for this commitment was "within 180 days of the submittal date of this response to Generic Letter 2003-01."
The time frame for the aforementioned commitment was established with the presumption that Industry/Technical Specification Task Force (TSTF) Standard Technical Specification change TSTF-448, Revision 1, Control Room Habitability, dated August 18, 2003, was to be approved by the NRC, well prior to the 180 day commitment due date. This would have allowed sufficient time for FENOC to adequately develop the proposed license amendment request. However, the NRC issued additional questions to the industry to support their review of TSTF-448, Revision 1, on December 16, 2003.
The industry responses to the NRC questions were provided on March 8, 2004.
With the time frame for NRC approval of TSTF-448 remaining uncertain, FENOC is hereby revising the due date for the commitment contained in FENOC Letter L-03-192, as described above, to be performed "within 180 days of NRC approval of TSTF-448."
This revised due date will allow FENOC to develop a license amendment request based upon an NRC approved version of TSTF-448 and will also avoid causing FENOC and the NRC to expend additional resources addressing future potentially unresolved industry 41Db
Beaver Valley Power Station, Unit No. 1 and No. 2 Revised Commitment for the 180-Day Response to Generic Letter 2003-01 L-04-042 Page 2 generic issues associated with this topic on a plant-specific basis. Attachment 1 provides a list of the commitments made in this letter, the commitment made in this letter supercedes the previous commitment made in FENOC letter L-03-192 as discussed above.
If you have questions or require additional information, please contact Mr. Larry R.
Freeland, Manager, Regulatory Affairs/Performance Improvement at 724-682-5284.
Sincerely, Willia earce Attachment c: Mr. T. G. Colburn, NRR Senior Project Manager Mr. P. C. Cataldo, NRC Sr. Resident Inspector Mr. H. J. Miller, NRC Region I Administrator
ATTACHMENT 1 Commitment List The following list identifies those actions committed to by FirstEnergy Nuclear Operating Company (FENOC) for Beaver Valley Power Station (BVPS) Unit Nos. 1 and 2 in this document. This commitment supercedes the previous commitment made in FENOC Letter L-03-192, dated December 5, 2003. Any other actions discussed in the submittal represent intended or planned actions by Beaver Valley. These other actions are described only as information and are not regulatory commitments. Please notify Mr. Larry R. Freeland, Manager, Regulatory Affairs/Performance Improvement, at Beaver Valley on (724) 682-5284 of any questions regarding this document or associated regulatory commitments.
Commitment Due Date Submit a License Amendment Request to propose Within 180 days of NRC revisions to the Technical Specification surveillance approval of TSTF-448 requirements on both BVPS units to utilize a more direct measurement method (i.e., leak rate test) to verify Control Room Envelope integrity and a periodic verification that a positive pressure is maintained between the Control Room Envelope and adjacent areas with the Control Room Emergency Ventilation System in operation.