IR 07200077/2025401
| ML25318B193 | |
| Person / Time | |
|---|---|
| Site: | Crane |
| Issue date: | 11/20/2025 |
| From: | Brice Bickett Decommissioning, ISFSI, and Reactor Health Physics Branch |
| To: | Rhoades D Constellation Energy Generation |
| References | |
| IR 2025401 | |
| Download: ML25318B193 (1) | |
Text
November 20, 2025
SUBJECT:
CRANE CLEAN ENERGY CENTER - NRC INDEPENDENT SPENT FUEL STORAGE SECURITY INSPECTION REPORT NO. 07200077/2025401
Dear Mr. Rhoades:
On September 25, 2025, the U.S. Nuclear Regulatory Commission (NRC) completed a security inspection at your Crane Clean Energy Center, Independent Spent Fuel Storage Installation (ISFSI),
in Middletown, Pennsylvania. The inspection covered your physical security plan and compliance with the October 16, 2002, Interim Compensatory Measures for Dry Independent Spent Fuel Storage Installations Order. This inspection was conducted using NRC Inspection Procedure 81311, Physical Security Requirements for Independent Spent Fuel Storage Installations.
The results of the inspection were discussed with Mr. Clint Six, Site Vice President, and other members of your staff during a final exit meeting held on September 25, 2025.
The inspection examined activities conducted under your license as they relate to security and compliance with the Commissions rules and regulations and with the conditions of your license.
Within these areas, the inspection consisted of an examination of selected procedures and representative records, observations of activities, and interviews with personnel.
Based on the results of this inspection, no violations were identified.
In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390, Public Inspections, Exemptions, Requests for Withholding, of the NRCs Rules of Practice, a copy of this cover letter and enclosure will be available electronically for public inspection in the NRCs Public Document Room or from the Publicly Available Records (PARS) component of the NRCs Agencywide Document Access Management System (ADAMS), accessible from the NRC Website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).
Sincerely, Brice Bickett, Chief Security, Emergency Preparedness and Incident Response Branch Division of Radiological Safety and Security
Docket No.
07200077 License No.
Enclosure:
Inspection Report No. 07200077/2025401
REGION I==
Inspection Report
Docket No.
07200077
License No.
Report No.
07200077/2025401
Enterprise Identifier:
I-2025-401-0025
Licensee:
Constellation Energy Group (CEG)
Facility:
Crane Clean Energy Center, Independent Spent
Fuel Storage Installation (ISFSI)
Location:
Middletown, PA
Inspection Dates:
September 23, 2025, to September 25, 2025
Inspectors:
T. Eck, Senior Physical Security Inspector
Approved By:
Brice A. Bickett, Branch Chief Security, Emergency Preparedness and Incident Response Branch Division of Radiological Safety and Security
SUMMARY
The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting an independent spent fuel storage installation security inspection at Crane Clean Energy Center Independent Spent Fuel Storage Installation, in accordance with the NRC Inspection Procedure 81311, Physical Security Requirements for Independent Spent Fuel Storage Installations.
List of Violations
No violations were identified.
Additional Tracking Items
None
INSPECTION SCOPE
Unless otherwise noted, independent spent fuel storage installation security inspections are conducted in accordance with the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection. Currently approved inspection procedures with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html.
The inspection was declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter 2690, Inspection Program for Dry Storage of Spent Reactor Fuel and Reactor Related Greater-Than-Class C Waste at Independent Spent Fuel Storage Installations and for 10 CFR Part 71 Transportation Packings. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.
Inspection Procedure 81311 - Physical Security Requirements for Independent Spent Fuel Storage Installations
This inspection was conducted in accordance with Sections 02.01 through 02.08, General License Requirements and Guidance for Co-Located / AFR ISFSI, of Inspection Procedure 81311, Physical Security Requirements for Independent Spent Fuel Storage Installations. All inspection requirements outlined in these sections of the IP were fully satisfied.
INSPECTION RESULTS
No violations were identified.
EXIT MEETING
The inspector verified no proprietary information was retained or documented in this report.
- On September 25, 2025, the inspector presented the inspection results to Clint Six, Site Vice President, and other members of the licensees staff.
DOCUMENTS REVIEWED
Inspection
Procedure
Type
Designation
Description or Title
Revision or Date
81311
Corrective Action
Documents
Reviewed
04849503, 04843438,
04844210, 04843304,
04843376, 04842733,
04839098, 04837961,
04779282, 04755297,
04691358, 04560518,
04543588
81311
Miscellaneous
TMI ISFSI Safeguards Event Reports
23, 2024, 2025
81311
TMI Nuclear Station ISFSI Security Plan
Revision 001
81311
NOSA-TMI-23-01
Security Programs Audit Report
March 15, 2023
81311
NOSA-TMI-25-02
Fitness for Duty Access Authorization Program
Audit Report
March 13, 2025
81311
Calculations
C-1101-114-012
Design Basis Threat Calculation
Revision 0
81311
Procedures
Contingency Response Guidance
Revision 0
81311
Security System Component Degradation
Compensatory Measures
Revision 0
81311
Physical Protection Measures for the ISFSI
Revision 0
81311
Conducting Patrols
Revision 0
81311
Control of Security Access Control Devices
Revision 0
81311
Testing Security Equipment
Revision 0
81311
Performance of Perimeter Intrusion Detection /
Camera System Testing
Revision 0
81311
Nuclear Security Training Program
Revision 0
81311
Firearms Maintenance, Testing and Accountability
Revision 0
81311
Testing Security Surveillance Systems
Revision 3
81311
OCA / Protected Area Searches
Revision 0
81311
Security Operational Duties
Revision 0