IR 07100708/2025201

From kanterella
Jump to navigation Jump to search
Westinghouse Electric Company, Inspection Report 07100708/2025201
ML25205A110
Person / Time
Site: 07100708
Issue date: 07/25/2025
From: Gerond George
NRC/NMSS/DFM/IOB
To: Stilwell W
Westinghouse, Columbia Fuel Fabrication Facility
References
IR 2025201
Download: ML25205A110 (1)


Text

SUBJECT:

WESTINGHOUSE ELECTRIC COMPANY - U.S. NUCLEAR REGULATORY COMMISSION INSPECTION REPORT NO. 710708/2025201

Dear Willliam Stilwell:

This letter refers to the inspection conducted on May 27 to 30, 2025, at the Westinghouse Electric Company (WEC) Columbia Fuel Fabrication Facility in Hopkins, South Carolina. The inspection team held a debrief at the end of the onsite inspection on May 30, 2025. Following in-office review, the team held a final exit teleconference on June 26, 2025. The purpose of the inspection was to verify and assess the adequacy of WEC's implementation and compliance with the U.S. Nuclear Regulatory Commission (NRC) requirements for the design, modification, fabrication, assembly, testing, maintenance, and procurement of the transportation packagings for which WEC is the Certificate of Compliance (CoC) holder. The inspection scope included reviews of records and interviews with personnel to determine whether transportation packagings are designed and maintained in accordance with the commitments and requirements specified in the applicable safety analysis report for packaging, the NRCs corresponding safety evaluation report, Title 10 of the Code of Federal Regulations (10 CFR)

Part 71, WECs NRC-approved quality assurance program, and the CoC. The enclosed report presents the results of this inspection.

The inspection examined activities conducted under your NRC-approved QAP as they relate to public health and safety, and to confirm compliance with the Commissions rules and regulations, and with the conditions of the applicable CoCs. Within these areas, the inspection consisted of selected examination of procedures and representative records, observations of activities, and interviews with personnel.

No violations of more than minor significance were identified during this inspection.

July 25, 2025 In accordance with 10 CFR 2.390, Public inspections, exemptions, requests for withholding, a copy of this letter, its enclosure, and your response (if any), will be made available electronically for public inspection in the NRC Public Document Room (PDR) or from the NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC website at http://www.nrc.gov/reading-rm/adams.html. The PDR is open by appointment. To make an appointment to visit the PDR, please send an email to PDR.Resource@nrc.gov or call 1800-3974209 or 301415-4737, between 8 a.m. and 4 p.m. eastern time (ET), Monday through Friday, except Federal holidays.

Sincerely, Gerond George, Chief Inspection and Oversight Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No. 710708

Enclosure:

Inspection Report No. 710708/2025201

Inspection Report

Docket No.:

710708

Report No.:

710708/2025201

Enterprise Identifier:

I20252010033

Certificate Holder:

Westinghouse Electric Company

Location:

Hopkins, SC

Inspection Dates:

May 2730, 2025

Inspectors:

Jeremy Tapp, Sr. Transportation and Storage Safety Inspector,

Team Leader

Raju Patel, Transportation and Storage Safety Inspector

Azmi Djapari, Transportation and Storage Safety Inspector

Gabriel Witter, General Engineer (Trainee)

Approved by:

Gerond George, Chief

Inspection and Oversight Branch

Division of Fuel Management

Office of Nuclear Material Safety

and Safeguards

SUMMARY

Westinghouse Electric Company

NRC Inspection Report 710708/2025201 This routine inspection performed at Westinghouse Electric Companys (WECs) facility in Hopkins, SC from May 27May 30, 2025, evaluated the ongoing activities related to the transportation of radioactive material in U.S. Nuclear Regulatory Commission (NRC)-approved transportation packagings. The purpose of the inspection was to verify and assess the adequacy of WECs transportation related activities to determine if they were performed in accordance with the requirements of Title 10 of the Code of Federal Regulations (10 CFR) Part 71, Packaging and Transportation of Radioactive Material, the Certificates of Compliance (CoCs) and safety analysis reports (SARs) for transportation packagings that WEC holds the CoC approval, and WECs NRC-approved quality assurance program (QAP).

Based on the results of this inspection, the NRC inspection team assessed that overall, the implementation of WECs QAP was adequate.

List of Findings and Violations

No violations of more than minor significance were identified.

Additional Tracking Items

None.

INSPECTION SCOPES

The inspection was conducted using the appropriate portions of Inspection Procedure (IP)86001, Design, Fabrication, Testing, and Maintenance of Transportation Packaging. Currently approved IPs are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess CoC holder performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards. The inspection was declared complete when the objectives of the IP were met, consistent with Inspection Manual Chapter 2690, Inspection Program for Storage of Spent Reactor Fuel and Reactor-Related Greater-Than-Class C Waste at Independent Spent Fuel Storage Installations and for 10 CFR Part 71 Transportation Packagings.

IP 86001 - Design, Fabrication, Testing, and Maintenance of Transportation Packaging Quality Assurance Program (IP Section 02.02)

The team verified that WECs activities related to transportation packagings are being conducted in accordance with the CoCs, as well as the NRC-approved QAP, and that implementing procedures are in place and effective.

The team reviewed WECs 10 CFR Part 71 QAP, Quality Management System-A, revision 8.1 and associated implementing procedures to verify and evaluate the effectiveness of the QAP implementation. The team performed reviews of the quality program, policies, and procedures, and discussed portions of these documents with selected personnel to determine whether WEC adequately controlled and implemented activities subject to 10 CFR Part 71 regulations. The team also reviewed the previous two revisions of the QAP to determine if changes made without prior NRC review and approval were performed in accordance with the requirements of 10 CFR 71.106, as applicable.

The team reviewed the QAP authorities and responsibilities to determine if they were clearly defined and documented, and the quality assurance (QA) organization functioned as an independent group. In addition, the team reviewed the QAP to determine if commercial grade dedication activities are performed by WEC. The team reviewed WECs graded approach to quality as documented in the QAP to verify WEC identified important-tosafety (ITS)components in its packaging designs in a graded approach as described.

10 CFR Part 21 (IP Section 02.03)

The team verified that provisions are in place for reporting defects which could cause a substantial safety hazard, as required by 10 CFR Part 21, Reporting of Defects and Noncompliance. The team reviewed WECs implementing quality procedures to verify whether provisions were in place for reporting defects that could cause a substantial safety hazard from the nonconformances and quality issues identified. The team reviewed selected records and interviewed personnel to verify that WEC effectively implemented a nonconformance control program in accordance with their NRC-approved QAP and the requirements of 10 CFR Part 21.

The team requested a list of 10 CFR Part 21 evaluations and notifications associated with any transportation activities and interviewed personnel to verify if WEC was familiar with the implementing procedure. The team also reviewed postings within the facility to determine whether WEC complied with 10 CFR 21.6, "Posting requirements."

Design Control (IP Section 02.04)

The team interviewed selected personnel and reviewed selected design documentation to determine that adequate design controls are implemented. The team focused its review on the areas of design modifications, quality classification evaluation for ITS components, review and control of design calculations, and verification and validation (V&V) of software programs.

Specifically, the team reviewed WEC design activities related to CoCs No. 71-9380 and 71-9297 for the Type B and Type A Traveller packages, respectively.

The team conducted interviews with design engineering personnel to review the design change process, including the initiation, analysis, verification, and approval of engineering change notices (ECNs). The team reviewed a sample of ECNs and design documentation associated with the Traveller package, including justification for safety classification of components such as the top axial restraint, bottom support spacer, and neutron poison plates to verify the components were adequately classified. The team also reviewed WECs design review process and associated documentation, including the sequence of internal design review meetings from design concept initiation to final design reviews to ensure conformance with quality procedures.

The team reviewed WECs use of the LS-DYNA software to perform structural analyses and support design work for the Traveller package. The team reviewed the V&V documentation of the software to assess whether it had been appropriately qualified for its intended application. In addition, the team reviewed a sample of hand calculations performed to independently verify the results of LS-DYNA simulations.

Fabrication, Assembly, Maintenance and Testing (IP Sections 02.05 and 02.06)

The team reviewed selected drawings, procedures and records, and observed selected activities being performed to determine whether the fabrication, test, and maintenance activities meet SAR design commitments and requirements documented in the CoC. The team also observed activities affecting safety aspects of the packaging (such as fabrication, assembly, and testing) to verify that they are performed in accordance with approved methods, procedures, and specifications.

The team performed a walkdown of transportation packagings used and stored onsite at WEC to assess their material condition and quality controls. This included the Traveller/Traveller XL and MCC-3, MCC-4, and MCC-5 packagings. The team reviewed maintenance activities for the Traveller packaging as it was the primary package used at WEC to transport fresh fuel.

Specifically, the team reviewed the procedures for refurbishment and recertification of Traveller packagings to verify adequacy and conformance to the SAR. The team also reviewed refurbishment and recertification documentation for a sample of Traveller packagings currently being used by WEC. Documentation included certifications, welding and inspection reports, completed inspection checklists, and special routings for non-routine maintenance items.

Further, the team observed Traveller maintenance activities that were ongoing while onsite and interviewed personnel associated with those activities to verify conformance to site quality procedures and SAR requirements. Specifically, the team observed Traveller 18-month refurbishment activities and shock mount replacement, as well as preparation for loading fresh fuel.

In addition, the team reviewed activities associated with Liqui-Rad (LR) Transport Unit packagings owned by WEC. As a result of the identification of corrosion on LR packagings during an NRC inspection at Nuclear Fuel Services (Inspection Report 71-0249/2023-201),

WEC took actions to perform refurbishment of the affected packagings. The team observed refurbishment activities at the contractor location, interviewed personnel, and reviewed quality procedures to determine the adequacy of the work being performed and if it was in accordance with the SAR and procurement requirements.

The team reviewed a sample of measuring and test equipment (M&TE) used for maintenance activities. The sample included a digital caliper, torque wrench, breakaway torque wrench, torque wrench calibrator, torque tester, and a 48 x 72 surface plate. The team toured the tool and gage lab on site to verify that M&TE were controlled, calibrated and maintained in accordance with WECs tool and gage lab control procedure. Calibration records were reviewed to verify calibration dates and due dates, the standards used, and traceability of the M&TE.

Procurement (IP Section 02.07)

The team reviewed selected drawings and records, and interviewed selected personnel, to verify that the procurement specifications for materials, equipment, and services received by the QAP holder meet the design requirements.

The team reviewed selected records and interviewed selected personnel to verify that the procurement specifications for equipment and services received by WEC met the design requirements. The team selected a sample of procurement documents from approved suppliers that included the purchase of O-rings, acetate plugs for Traveller packagings, maintenance services, helium leak test standards and calibration services. The team also reviewed WECs processes and procedures that address procurement to determine they are adequate to ensure that any procured material, services, and equipment meet the design specifications.

Nonconformance and Corrective Action Programs (IP Section 02.08)

The team reviewed selected records and interviewed selected personnel to verify that a nonconformance control program is effectively implemented, and that corrective actions for identified deficiencies are technically sound and completed in a timely manner. The review included an evaluation of how WECs nonconformance control program and corrective action program addressed materials, parts, and components that do not conform to requirements and identified quality deficiencies. The team also reviewed provisions for reporting defects that could cause a substantial safety hazard within these programs.

Specifically, the team reviewed a sample of nonconformance reports (NCRs) and issue reports (IRs) since the last NRC inspection in 2020, including an IR generated because of a previous NRC identified violation to ensure adequate corrective actions were implemented to correct the issues. The team also sampled IRs initiated from 10 CFR 71.95 evaluation reports. The team interviewed personnel regarding the Model No. Liqui-Rad Transport Unit Package corrosion issue to verify if WEC had taken actions to address this issue to prevent future recurrence.

The team focused the NCR review on use-asis and repair type dispositions to evaluate how WEC technically justified the approved dispositions. The IRs were reviewed to determine whether WEC completed corrective actions for identified deficiencies in a technically sound and timely manner, including assessment of reporting in accordance with 10 CFR Part 21 and 10 CFR Part 71 requirements. The team also reviewed five 10 CFR 71.95 reports initiated by WEC from 2020 through 2025, to determine whether WEC had addressed and resolved the issues through their CAP in a timely manner. The performance monitoring and trending report for 2024 was reviewed to verify it was performed as required and comprehensive in nature.

Personnel Training and Certifications (IP Section 02.09)

The team reviewed selected records and procedures, interviewed selected personnel, and observed selected activities to verify that individuals performing activities affecting quality are properly trained and qualified. The team verified that management and QA staff are cognizant and provide appropriate oversight.

The team reviewed procedures and documents regarding training, qualification, and certification of personnel involved in quality activities. The team reviewed the qualifications and training for selected lead auditors to determine if they met the requirements stated in the QAP. The team also reviewed the qualification records of engineering personnel responsible for performing design activities and approving design changes related to the Traveller package. In addition, the team reviewed training records for a random sample of personnel in quality-related positions to determine if they received the required indoctrination to and familiarization with the QAP.

The team also reviewed selected records and procedures, interviewed personnel, and discussed the maintenance activities affecting the safety aspects of the Traveller packaging to verify that WEC provided oversight and had trained and qualified individuals performing maintenance activities, including welding, inspection and nondestructive examination.

Audit Program (IP Section 02.10)

The team verified that audits of the QAP and activities affecting the safety aspects of the packaging are scheduled, have been performed as scheduled, and that identified deficiencies have been satisfactorily resolved in a timely manner.

The team reviewed the WEC audit program to determine whether WEC scheduled, planned, and performed internal audits in accordance with applicable regulations and QAP requirements.

The team reviewed a sample of internal audits conducted between 2022 and 2024 to determine if all applicable QAP elements were audited annually and in accordance with the established audit schedules.

The team reviewed a sample of external audits and supplier evaluations for the suppliers of procured components and services to determine if each supplier was audited either by the Nuclear Industry Assessment Corporation (NIAC) with an audit report evaluated and accepted by WEC as required, or audited by WEC itself and an annual assessment performed for continued placement on the qualified suppliers list. The team determined whether the scope of the NIAC audits were comprehensive and applicable to WECs procurement activities.

The team determined for audits that identified findings, whether corrective actions were entered into the CAP as required, and closures were verified either during the same audit or in the subsequent years audit, as documented in follow-up audit reports.

INSPECTION RESULTS

No violations of more than minor significance were identified.

EXIT MEETING/DEBRIEFS The team verified no proprietary information was retained or documented in this report.

  • On May 30, 2025, the team presented the preliminary inspection results to William Stilwell, Nuclear Fuel Transport Director, and other members of the CoC holders staff.
  • On June 26, 2025, after in-office review, the team presented the final inspection results to William Stilwell, Nuclear Fuel Transport Director, and other members of the CoC holders staff.

DOCUMENTS REVIEWED

Inspection

Procedure

IP 86001 - Design, Fabrication, Testing, and Maintenance of

Transportation Packaging

Type

Designation

Description or Title

Revision

or Date

W-21-180

Internal Audit Report

9/21/2021

W-22-54

Internal Audit Report

2/9/2022

W-2023-19

Internal Audit Report

2/11/2023

W-2024-38

Internal Audit Report

2/9/2024

WES-2025-102

Audit of EnergySolutions, Barnwell

facility

2/27/2025

WES-2022-157

Audit of Leak Testing Specialists, Inc.

4/28/2022

WES-2024-105

Audit of Carolina Energy Solutions,

LLC

8/2/2024

WEC Annual Evaluation of

EnergySolutions

3/6/2024

WEC Supplier Annual Evaluation of

Leak Testing Specialists Inc.

4/10/2024

WEC Supplier Annual Evaluation of

Carolina Energy Solutions

3/1/2024

Audits

WES-2024-169

Audit of ANSYS, Inc.

5/24/2024

QC30607

Torque Wrench

3/10/2025

QC27226

Tool Overview - Digital Caliper

5/14/2025

QC17651

Torque Analyzer (EZ TORQ)

1/9/2025

QC05304

Gage Blocks Set

7/9/2024

QC10970

Torque Tester

9/1/2021

Calibration

Documents

CM27876

20-150 ft/lb Breakaway Torque Wrench

3/4/2025

IR-2019-1818

Source 71.95 Report LTR-LCPT-19-03

1/30/2019

IR-2019-18073

Source: 2019 NRC Inspection

Identified Issue

2/12/2019

IR-2019-18112

Source: 2019 NRC Inspection

Identified Issue

2/12/2019

Corrective

Actions

IR-2020-1360

Source: 2019 NRC Inspection identified

issue

2/3/2020

IR-2020-4142

Source: 71.95 Report LTR-LCPT-20-08

3/27/2020

IR-2021-9214

Source: 71.95 Report LTR-LCPT-21-13

8/24/2021

IR-2022-11146

Source: 71.95 Report LTR-LCPT-22-24

2/14/2022

IR-2024-2239

Source: 71.95 Report LTR-LCPT-24-10

5/5/2024

IR-2024-7267

Source: Internal Audit Corrective Action

5/7/2024

IR-2024-1472

Water found in bottom of Traveller

Container during PEMQ Fuel Receipt

2/13/2024

23-518

IR 2023-518

23-519

IR-2023-519

231241

IR 20231241

241387

IR20241387

241472

IR 20241472

25-452

IR-2025-452

251387

IR 20251387

252816

IR 20252816

25-5481

IR 2025-5481

25-5540

IR-2025-5540

25-5708

IR-2025-5708

0004127

ECN-0004127

0003840

ECN-0003840

0003752

ECN-0003752

Design Change

Request

0004203

ECN-0004203

CN-NFPE-07-179

Installation testing of LS-DYNA Version

970 Revision 5434a

CN-LCPT-22-01

Traveller STD & XL 8-Inch Rod Pipe

Loose Rod Content Criticality Safety

Analysis

CN-NFPE-23-005

Traveller 8-Inch Loose Rod Pipe Finite

Element Drop Test Analysis

CN-NFPE-23-006

Traveller 8-Inch Loose Rod Pipe

Structural and Thermal Evaluations

PE-TECH-24-050

Fuel Assembly and Shipping Package

Contract Engineer Qualifications

PE-TEST-24-010

Traveller 8-Inch Loose Rod Pipe Final

Verification Drop Test Report

Mechanical Design Manual Volume 3,

Shipping Containers, Chapter 5,

Classification of Parts

6/3/2024

SFDT-19-70

Traveller Type B Shipping Package

Safety Related Assembly and Part

Classification

Design

Documents

MD1-04-110

Traveller STD Shipping Package

Safety Related Part Classification

PS134B

CoC for Acetate Plug

8/12/2024

PO 4160204488

Acetate Plug

3/21/2024

PO 4500883957

LR-230 Package Refurbishment

6/26/2023

PO 4500796907

Calibration Services

3/31/2020

Procurement

Documents

PO 4500796907

Calibration Services

CN-3

PO 4500916579

Calibration Services

8/26/24

PO 4500916579

Calibration Services

CN-1

LCPT-23-05

Technical and Quality Requirements

for Liqui-Rad Refurbishment Project

2/16/2024

LTR-LCPT-24-09

WEC/Orano TN Approval of Energy

Solutions Liqui-Rad Packaging

Refurbishment Procedure

4/10/2024

CF-75B-018

Traveller Refurbishment Verification

Checklist

CF-MN-WI-008

Westinghouse Liqui-Rad Packaging

Refurbishment Exploratory Rework

CF-MN-WI-009

Westinghouse Liqui-Rad Packaging

Refurbishment Rework

CF-MN-WI-010

Westinghouse Liqui-Rad Packaging

Ultrasonic Thickness (UT) Inspection

CF-MN-WI-011

Westinghouse Liqui-Rad Packaging

Internal Foam Exploratory Work

COP-836052

Annual Maintenance and Inspection of

LR-230 Shipping Packagings

ES-QA-PR-007

QC Personnel Qualification and

Certification

TRS-225-1

Traveller Shipping Package Visual

Guidelines

QCI-000140

Tool and Gage Control Lab

QCI-000150

Qualification of Welding Procedures

and Personnel

QCI-000210

Receiving Inspection

TAF-502-1

Traveller Shock Mount Replacement

TR-223

Weld Shipping Packaging

TR-225

Refurbish Traveller Shipping Package

TR-229

Traveller Recertification

EP-103

Training and Qualification

33.2

EP-201

Test Prospectus and Test Report

27.5

EP-310

Computer Software Development and

Maintenance

31.9

EP-404

Engineering Change Notice

W2-8.1-102

Engineering Peer Review

2.0

W2-8.3-101

Design Analysis

4.1

W2-8.4-101

Design Review

4.0

W2-8.5-101

Design Configuration Control

1.0

W2-8.5-106

Design Change

0.1

W2-8.6-105

External Computer Software

2.0

QMS-A

Quality Management System-A

8.1

QA-008

Nondestructive Test Certification

QA-600

Westinghouse Management

System/QA Program Implementation

Information Use

18.0

Program or

Procedure

QA-600-3

Quality Assurance Program For Fuel

Package Used in the Transportation of

10.0

Radioactive Material List of

Implementing Procedures

QA-608

Identification, Traceability and Control

of Materials, Parts and Components

QA-609

Control of Special Processes

QA-610

Inspection

QA-611

Test Control

QA-612

Control of Inspection, Measuring, and

Test Equipment

QA-613

Handling, Storage, Packing,

Preservation and Delivery

QA-617

Processing of Electronic Problem

Notice (EPN)

43.0

W2-2.5-200

Personnel Qualification and

Certification

1.1

W2-4.2-101

Internal Quality Assurance Audits

5.0

W2-5.1-101

Westinghouse Corrective Action

Program

10.1

W2-5.1-201

Identification and Reporting of

Conditions Adverse to Nuclear Safety

3.0

W2-9.4-101

Control of Purchased Items and

Services

8.2

W2-9.4-102

Deviation Notices

3.0

W2-9.5-101

Supplier QA Program Qualification and

Assessment

3.0

W2-9.5-102

Commercial Dedication Process

2.0

W2-9.5-102.W01

Alternate Method for Dedication of

Calibration and Testing Services

0.3

W2-9.5-104

Supplier Oversight

2.0

W2-9.5-105

Control of Suppliers on the ASL and

QSL

3.0

W2-9.8-100

Control of Measuring and Test

Equipment

2.0

W2-9.14-100

Control of Nonconforming Process

Outputs, Products, and Services

2.0

EP-406

Disposition of Deviations and

Nonconforming Items

2.6

CA-204

Deviation Disposition

30.0

RA-130

Regulatory Agency Communication

and Postings

13.0

QA-2.8

Qualification of Audit Personnel

2.2

QA-7.14

Annual Supplier Evaluation

4.0

PD-03-25

Traveller Shipping Package Safety

Related Part and System Classification

Procedure

LTR-LCPT-23-11

Submittal of 71.106(b) Report

8/9/2023

LTR-LCPT-19-03

Incorrect Criticality Safety Index Used

on labels on Traveller package

3/25/2019

Reports

LTR-LCPT-20-08

Security Seal incorrectly applied

5/19/2020

LTR-LCPT-21-13

Non-fixed contamination on the outside

of package exceeded regulatory limits

10/22/2021

LTR-LCPT-22-24

Port bolt missing

1/6/2023

LTR-LCPT-24-10

Locking Pin disengaged

4/15/2024

LTR-LCPT-21-11

Supplement for Amendment Request

Application for USA/9380/B(U)F-96 for

Model No. Traveller STD and XL

Packages

3/11/2022

LTR-LCPT-24-22

Supplement SAR for Renewal

Application for USA/9297/AF-96 for

Model No. Traveller STD, XL, and

VVER Packages

7/1/2024

WCAP-07109297-

P

Application for Certification of

Compliance for the Traveller PWR Fuel

Shipping Package

Safety Analysis

Reports

Liqui-Rad Transport Unit Safety

Analysis Report

PDSHIP02

TRAVELLER Polyurethane Foam

Specification

PDSHIP04

TRAVELLER Specification for Neutron

Poison

Specifications

PDSHIP05

TRAVELLER Shipping Package

Specification

11