YW
>
,
OCT 2 41985 Faygo Beverages 3579 G(atiot Avenue Detroit, MI 48270 Gentlemen:
As a result of the inspection conducted on August 23 to September 13, 1985, a Form NRC-591, SAFETY INSPECTION, is issued for your NRC general license. The enclosed form sets forth the items of noncompliance noted.
Please acknowledge receipt of this form by signing and dating in the appropriate space on all copies. You are requested to retain the original and return four signed and
-
dated copies to this office within ten days.
The enclosed copy of our inspection report identifies areas examined during
, v#,
the inspection. Within these areas, the inspection consisted of a selective
examination of procedures and representative records, observations, and jj telephone interviews with your personnel.
.
If you have any questions or require clarification on any of the information stated above, you may contact us at (312) 790-5616.
Thank you for your cooperation.
Sincer
,
C
- 7
.
.
D. G. Wiedeman, Chief Nuclear Materials Safety Section 1 Enclosures: As stated bec w/ enclosures:
\\
L. Cobb, 0IE h
S. Baggett, NMSS n
@D
-
F RIII
..
Wiedeman/1d 10/22/85 9901130357 851024 PDR RC
SSD PDR
_
..
.
.
__
.-.
_
..
. ~.
---.
. _ _.
- - ~ -. -
-
- -
, _ _
-. -
.
I;.
l*
GENERAL LICENSE GAUGE DATA COLLECTION FORM 1.
Name and Address of General Licensee:
Faygo Beverages 3579 Gratiot Avenue Detroit, MI 48270
'
(313) 925-1600 2.
Principal Business of Licensee:
Canning Carbonated Beverages 3.
Purpose for which gauge (s) are used (e.g., measurement of level, density, flow, thickness,etc.):
,
Measurement of Level
-
4.
Gauge Specifics:
'
a.
Manufacturer: Accuray Corporation Model Number:
FLIR 201 (one gauge)
htgj2"[k,
,,
Isotope / Activity:
cesium-137/14 mil 11 curies Date Received: Unknown Date Returned: May 26, 1972 b.
Manufacturer:
Industrial Dynamics Company, Ltd.
Model Number:
FIL-TEC (two gauges)
Isotope / Activity:
americium-241/100 mil 11 curies Date Received:
unknown Date Returned: N/A
5.
Name of specific licensee that installed gauge:
Unknown.
6.
Does the gauge have a durable, legible and visible label:
Yes.
7.
Was an Initial Radiation Survey performed at time of installation and do they have a record (list results) NOTE:
records only required for 2 year period:
Unknown.
8.
Leak Tests:
!
a.
Have the tests been performed (list results):
Yes, less than.005 microcuries on all tests performed.
,
l l
. _.. _ _ _ ____
_ _ _ _. _ _ _ _ _. _.
.. _ _ _. _ _ _.. _ _ _ _ _ _ _. _ _ _
_ _ _ _. _ _ _..
.
.
I
[
b.
Name of firm / person conducting test:
Industrial Dynamics Company, Ltd.
Are records available of tests (list date of last test):
,
c.
l NOTE:
records only maintained for 2 years
,
Only one test record readily available at the time of my only l
contact with Bill Wyszyski, April 25, 1985.
i
!
9.
Operational Test of Gauge:
a.
Have any tests been performed of the on/off mechanism:
(
Yes, tests okay when performed.
b.
Name of firm / person who performed test:
,
Industrial Dynamics Company, Ltd.
--
c.
Are records maintained of tests (list dates):
April 25, 1985.
10. Has the gauge been moved from it's original location?
If so, by whom:
Yes, Accuray Corporation gauge returned on May 26, 1972.
)
j 11.
Does the licensee have personnel who are responsible for assuring compliance with the General License Conditions (10 CFR 31, 31.5(c)
,
(1 through 10):
i Bill Wyszyski, Manager of Engineering and Maintenance 12. Has the licensee made any transfers of gauges:
,
Accuray Corporation, gauge returned on May 26, 1972.
l
.13.
Name and Address of Gauge Manufacturer:
l l
Accuray Corporation Industrial Dynamics Company, Ltd.
'
P.O. Box 02248 2927 Lomita Boulevard 650 Ackerman Road Torrance, CA 90509 Columbus, Ohio 43202 14. Onsite inspection of gauge (s) (list observations / measurements):
Notes: On my first and only contact with Bill Wyszyski, he had readily available only one test record on his Fil-Tec units for April 25, 1985.
Said he would call with additional information as soon as he could get
it.
Subsequent phone calls to Bill resulted in no-contact and my calls
9
l
'
,
__
_
_
. -..
.
. _
_
~
-
_ -.
-
.-
- _..
_
o were not returned.
Information from Accuray Corporation indicated that l
the Accuray gauge was returned to Accuray Corporation.
Industrial l
Dynamics records showed negative test results for the two Fil-Tec units on these dates: April 8, 1985; October 22, 1984; June 9, 1982; and June 8, 1981.
15.
Name of ORAU Reviewer l
/
/.
. W =
,4ony A/IsA[r'
-
'
'
~~
DEte /
l l
16.
Signature and Date of NRC Reviewer
'
A:,
A/$s/l/
.
.
.
O' ate '
t l
l l