IR 05000607/2003202

From kanterella
Jump to navigation Jump to search
IR 05000607-03-202, on 01/13-15/2004, for University of California, Davis Mcclellan Nuclear Radiation Center
ML040580326
Person / Time
Site: University of California-Davis
Issue date: 03/04/2004
From: Madden P
NRC/NRR/DRIP/RNRP
To: Klein B
McClellan Nuclear Research Center
dragoun T, NRR/DRIP/RNRP, 610-337-5373
References
IR-03-202
Download: ML040580326 (10)


Text

March 4, 2004

SUBJECT:

NRC SPECIAL INSPECTION REPORT NO. 50-607/2003-202

Dear Dr. Klein:

This refers to the special inspection conducted on January 13 - 15, 2004, at the University of California, Davis Nuclear Radiation Center. The inspection included a review of the selected reactor operational routine activities authorized for your facility. The enclosed report presents the results of that inspection.

Areas examined during the inspection are identified in the report. Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations of activities in progress. Based on the results of this inspection, one Non-Cited Violation (NCV) of Technical Specification (TS) 6.1.4 requirements was identified. Specifically, the training and experience of the person filling the new Operations Manager position, approved by TS Amendment No. 6 in November 2003, did not satisfy the training and experience requirements in TS 6.1.4. The details regarding this matter can be found in Section 1 of the attached report. This was a non-repetitive, promptly corrected violation and is being treated as an NCV in accordance with the General Statement of Policy and Procedure for NRC Enforcement Actions, (Enforcement Policy), NUREG 1600.

The current Enforcement Policy is included on the NRC's Web site at www.nrc.gov; select What We Do, Enforcement, then Enforcement Policy. If you contest the violation or significance of the NCV, you should provide a response within 30 days of the date of this letter with the basis for your denial, to the United States Nuclear Regulatory Commission, ATTN:

Document Control Desk, Washington, DC 20555-0001, with a copy to the Director, Office of Enforcement, United States Nuclear Regulatory Commission, Washington, DC, 20555-0001.

In accordance with 10 CFR 2.790 of the NRC's Rules of Practice, a copy of this letter, without enclosure, will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document system (ADAMS). ADAMS is accessible from the NRC Web site at (the Public Electronic Reading Room) http://www.nrc.gov/reading-rm/adams.html.

Dr. Barry Should you have any questions concerning this inspection, please contact Mr. Thomas Dragoun in King of Prussia, Pennsylvania at 610-337-5373.

Sincerely,

/RA/

Patrick M. Madden, Section Chief Research and Test Reactors Section New, Research and Test Reactors Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket No. 50-607 License No. R-130 Enclosure: NRC Inspection Report No. 50-607/2003-202 cc w/enclosure: Please see next page

University of California - Davis/McClellan MNRC Docket No. 50-607 cc:

Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611

Dr. Barry