IR 05000605/2008012

From kanterella
Jump to navigation Jump to search
Discusses Insp Conducted on 850605-0812 & Forwards Safety Insp Rept.No Violations Observed
ML20199B281
Person / Time
Site: 05000605
Issue date: 10/18/1985
From: Wiedeman D
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
External (Affiliation Not Assigned)
Shared Package
ML20199B285 List:
References
SSD, NUDOCS 9901130298
Download: ML20199B281 (4)


Text

{{#Wiki_filter:_ _. _ _ _. _ _ _ _ _. _. - . _ _ _ _ _..... _ _. _. _. -. _. _. _. _ _ _ _. _. _ _ _ _ _. _. $ AMAS o , i i [] , l (ffjAr . 00T 181985 / i Interlake Incorporated 4/'/pf[M 13500 South Perry Avenue

-Riverdale, IL 60627

N Gentlemen: . As a result of the inspection conducted on June 5 to August 12, 1985, a i Form NRC-591, SAFETY INSPECTION, is issued for your NRC general license.

You 'r will note that this form indicates that no item of noncompliance was found.

It is not necessary that you acknowledge receipt of this form.

i ! ! The enclosed copy of our inspection report Wentifies areas examined during ' l.

the inspection.

Within these areas, the inspection consisted of a selective ' l examination of procedures and representative records, observations, and ! l telephone interviews with your personnel.

j

If you have any' questions or require clarification on any of the information j stated above, you may contact.us at (312) 790-5616.

i Thank you for your cooperation.

Sincerely, ,

t ! I ' i D. G. Wiedeman, Chief i Nuclear Materials Safety - , l Section 1 Enclosures: As stated , bcc w/ enclosures: \\ \\ l L. Cobb, OIE l S. Baggett, NMSS

\\ L . i '

RIII l Wiedeman/1d 190>oeou ! -10/16/85-

. / 9901130298 851018 l '

'PDR RC

(, SSD PDR , , . . . . . -- .. - .- -

.- - . .-._~..- --... .._.- .-.. . .-.-.- .. .. -.. P $ E GENERAL LICENSE GAUGE DATA COLLECTION FORM l 1.

Name and Address of General Licensee:

Interlake Incorporated l-13500 South Perry Avenue Riverdale, IL 60627 (312) 849-2500 l.

2.

Principal Business of Licensee:

Steel Production.

) l 3.- Purpose for which gauge (s) are used (e.g., measurement of level, density, flow, thickness,etc.): Thickness.

> '1 i l 4.

Gauge Specifics: a.

Manufacturer: Accuraydorporation b.

Device Number: U-6 - c.

Isotope / Activity: strontium- 0/800 mil 11 curies S/N: S-202-R l d.

Date Received: April 1980 'b'); , l e.

Date Replaced: C M i . 5.

Name of specific licensee that installed gauge: ' Accuray Corporation -< , , ! 6.

Does the gauge have a durable, legible and visible label: Yes.

7.

Was an Initial Radiation Survey performed at time of installation and

! do they have a record (list results) NOTE: records only required for 2 l year period: l-N/A.

Past two years since installation.

, 8.

Leak Tests: l l a.

Have the tests been performed (list results): Less than 0.001 microcuries , i ' b.

Name of firm / person conducting test: Interlake Incoporated/ Bob Oblon License No. 12-16147-03 . $. __ .. _ _ _ _. _..,.

c.

Are records available of tests (list date of last test): NOTE: records only maintained for 2 years Yes, July 16, 1985; January 16, 1985; July 18, 1984; and January 16, 1984.

9.

Operational Test of Gauge: a.

Have any tests been performed of the on/off mecnanism: Yes.

All shutters, warning lights, and interlocks - Okay.

b.

Name of firm / person who performed test: Interlake Incorporated / Bob Oblon License No. 12-16147-03 !

c.

Are records maintained of tests (list dates): I Yes, July 16, 198s; January 16, 1985; July 18, 1984; and January 16,

1984.

l

10.

Has the gauge been moved from it's original location? If so, by whom: I Yes.

Accuray Corporation removed the gauge, placed it in storage, then I returned it to its original location, January 11, 1983 and January 18, 1983.

11.

Does the licensee have personnel who are responsible for assuring compliance with the General License Conditions (10 CFR 31, 31.5(c) (1 through 10): Bob Oblon ' 12. Has the licensee made any Nansfers of gauges: No.

13.

Name and Address of Gauge Manufacturer: Accuray Corporation P.O. Box 02248 650 Ackerman Road Columbus, Ohio 43202 , 14.

Onsite inspection of gauge (s) (list observations / measurements): N/A.

15.

Name of ORAU Reviewer-l ' ! / gggy [[" ~ [ A t- . / Date

. ... - - .. -. - _... - -...... - - -... - .... - ~. =,... -. - -. -... -. --- a .%

1.

16.

Signature and Date of NRC Reviewer .- ' ) / l ,' $

h \\ /0 */7'[f . , Date i i

' s L I I

l l l I f I .* I r I'

s t.

l.

. }}