Category:Inspection Report
MONTHYEARIR 05000320/20240012024-08-28028 August 2024 TMI-2 Solutions, LLC, Three Mile Island Nuclear Station, Unit 2 - NRC Inspection Report Nos. 05000320/2024001 and 05000320/2024002 IR 07200077/20240012024-06-18018 June 2024 Constellation Energy Generation, LLC, Three Mile Island Nuclear Station, Unit 1 - NRC Inspection Report No. 07200077/2024001 IR 05000320/20230042024-02-0707 February 2024 TMI-2 Solutions, LLC, Three Mile Island Nuclear Station, Unit 2 - NRC Inspection Report 05000320/2023004 IR 05000289/20230062024-01-29029 January 2024 Constellation Energy Generation, LLC, Three Mile Island Nuclear Station, Unit 1 - NRC Inspection Report No. 05000289/2023006 IR 05000320/20230032023-11-28028 November 2023 TMI-2 Solutions, LLC, Three Mile Island Nuclear Station, Unit 2, NRC Inspection Report No. 05000320/2023003 IR 05000320/20230022023-08-17017 August 2023 TMI-2 Solutions, LLC, Three Mile Island Nuclear Station, Unit 2 - NRC Inspection Report 05000320/2023002 IR 05000289/20230052023-08-14014 August 2023 Constellation Energy Generation, LLC, Three Mile Island Nuclear Station, Unit 1 - NRC Inspection Report 05000289/2023005 IR 05000320/20230012023-04-12012 April 2023 TMI-2 Solutions, LLC, Three Mile Island Nuclear Station, Unit 2 - NRC Inspection Report No. 05000320/2023001 IR 05000320/20220042023-02-16016 February 2023 TMI-2 Solutions, LLC, Three Mile Island Nuclear Station, Unit 2 - NRC Inspection Report Nos. 05000320/2022004 and 05000320/2022401 IR 05000289/20220022023-02-13013 February 2023 Constellation Energy Generation, LLC, Three Mile Island Nuclear Station, Unit 1 – NRC Inspection Report Nos. 05000289/2022002 and 005000289/2022402 IR 05000289/20220012022-08-26026 August 2022 Constellation Energy Generation, LLC, Three Mile Island Nuclear Station, Unit 1 - NRC Inspection Report Nos. 05000289/2022001 and 07200077/2022001 ML22228A0142022-08-17017 August 2022 TMI-2 Solutions, LLC, Three Mile Island Nuclear Station, Unit 2 - NRC Inspection Report IR 05000289/20224012022-04-12012 April 2022 NRC Security Decommissioning Inspection Report No. 05000289/2022401 IR 05000289/20210022022-01-31031 January 2022 NRC Inspection Report 05000289/2021002 and 07200077/2021001 IR 05000320/20210042022-01-27027 January 2022 TMI-2 Solutions, LLC, Three Mile Island Nuclear Station, Unit 2 - NRC Inspection Report 05000320/2021004 IR 05000289/20210012021-06-28028 June 2021 NRC Inspection Report No. 05000289/2021001, Exelon Generation Co., LLC, Three Mile Island Nuclear Station, Unit 1 IR 05000289/20214012021-06-28028 June 2021 Security Decommissioning Inspection Report 05000289/2021401 IR 05000320/20210032021-06-22022 June 2021 TMI-2 Solutions, LLC, Three Mile Island Nuclear Station, Unit 2 - NRC Inspection Report 05000320/2021003 IR 05000289/20200052021-02-0101 February 2021 NRC Inspection Report No. 05000289/2020005, Exelon Generation Co., LLC, Three Mile Island Nuclear Station Unit 1 IR 05000320/20200022020-10-19019 October 2020 Gpu Nuclear, Inc., Three Mile Island Nuclear Station, Unit 2, NRC Inspection Report 05000320/2020002 IR 05000289/20204012020-09-0101 September 2020 Unit 1 - Security Baseline Inspection Report 05000289/2020401 IR 05000289/20200032020-07-20020 July 2020 NRC Inspection Report No. 05000289/2020003, Exelon Generation Co., LLC, Three Mile Island Nuclear Station, Unit 1 IR 05000289/20200012020-04-30030 April 2020 NRC Inspection Report 05000289/2020001 IR 05000289/20190102020-02-0404 February 2020 NRC Inspection Report No. 05000289/2019010, Exelon Generation Co., LLC, Three Mile Island Unit 1, Middletown, PA IR 05000289/20190032019-11-0606 November 2019 Integrated Inspection Report 05000289/2019003 IR 05000289/20190052019-08-28028 August 2019 Updated Inspection Plan Inspection Report 05000289/2019005 IR 05000289/20193012019-08-15015 August 2019 Initial Operator Licensing Examination Report 05000289/2019301 IR 05000289/20190022019-08-0909 August 2019 Integrated Inspection Report 05000289/2019002 IR 05000320/20190012019-06-10010 June 2019 Gpu Nuclear, Inc., Three Mile Island Station, Unit 2 - NRC Inspection Report 05000320/2019001 IR 05000289/20195012019-06-0303 June 2019 Emergency Preparedness Biennial Exercise Inspection Report 05000289/2019501 IR 05000289/20194102019-03-18018 March 2019 Baseline Security Inspection Report 05000289/2019410 IR 05000289/20180062019-03-0404 March 2019 Annual Assessment Letter for Three Mile Island Station, Unit 1 (Report 05000289/2018006) IR 05000289/20180042019-01-31031 January 2019 Integrated Inspection Report 5000289/2018004 IR 05000289/20182012018-12-13013 December 2018 NRC Inspection Report 05000289/2018201 IR 05000289/20180032018-11-0808 November 2018 Integrated Inspection Report 5000289/2018003 IR 05000289/20184102018-09-18018 September 2018 Baseline Security Inspection Report 05000289/2018410 (Letter Only) IR 05000289/20180052018-08-28028 August 2018 Updated Inspection Plan Inspection Report 05000289/2018005 IR 05000289/20180022018-08-0202 August 2018 Integrated Inspection Report 5000289/2018002 IR 05000320/20180112018-05-23023 May 2018 NRC Inspection Report 05000320/2018011 IR 05000289/20180102018-05-0202 May 2018 Design Bases Assurance Inspection (Teams) Report 05000289/2018010 IR 05000289/20180012018-05-0202 May 2018 Integrated Inspection Report 5000289/2018001 and Exercise of Enforcement Discretion IR 05000289/20170062018-02-28028 February 2018 Annual Assessment Letter for Three Mile Island Station-Unit 1 (Reports 05000289-2017006 and 05000289-2017402 and 05000289-2017501) IR 05000289/20170042018-01-25025 January 2018 Integrated Inspection Report 05000289-2017004 IR 05000289/20174052017-11-29029 November 2017 Problem Identification and Resolution Cyber Security Inspection Report 05000289/2017405 (Cover Letter) IR 05000289/20170032017-10-25025 October 2017 Integrated Inspection Report 5000289/2017003 IR 05000289/20174032017-09-25025 September 2017 Baseline Security Inspection Report 05000289/2017403 (Cover Letter) IR 05000289/20170052017-08-28028 August 2017 Updated Inspection Plan for Three Mile Island Station, Unit 1, with Report 22 (Report 05000289/2017005) IR 05000289/20170102017-08-25025 August 2017 Susquehanna Steam Electric Station, Units 1 and 2 - Problem Identification and Resolution Cyber Security Inspection Report 05000387/2017405 and 05000388/2017405 (Cover Letter) IR 05000289/20173012017-08-23023 August 2017 Initial Operator Licensing Examination Report 05000289/2017301 IR 05000289/20170022017-08-0808 August 2017 Integrated Inspection Report 05000289/2017002 2024-08-28
[Table view] Category:Letter
MONTHYEARRS-24-097, Notice of Intent to Pursue Subsequent License Renewal for Three Mile Island Nuclear Station, Unit 12024-10-23023 October 2024 Notice of Intent to Pursue Subsequent License Renewal for Three Mile Island Nuclear Station, Unit 1 ML24256A0422024-10-0404 October 2024 Updated Post-Shutdown Decommissioning Activities Report, Rev. 6 ML24240A1692024-09-18018 September 2024 Cy 2023 Summary of Decommissioning Trust Fund Status ML24242A3032024-09-0909 September 2024 Letter - Three Mile Island Station, Unit 2, Issuance of Amendment No. 68, Historic and Cultural Resources IR 05000320/20240012024-08-28028 August 2024 TMI-2 Solutions, LLC, Three Mile Island Nuclear Station, Unit 2 - NRC Inspection Report Nos. 05000320/2024001 and 05000320/2024002 ML24240A2222024-08-27027 August 2024 Response to Request for Additional Information for the TMI-2 Post-Shutdown Decommissioning Activities Report, Rev. 6 ML24220A2742024-08-15015 August 2024 Request for Additional Information Clarification Call Regarding Three Mile Island Station, Unit 2, Amended Post-Shutdown Decommissioning Activities Report, Rev. 6 ML24135A3292024-08-0909 August 2024 Amendment No 68, Historic and Cultural Resources Cover Letter IR 07200077/20240012024-06-18018 June 2024 Constellation Energy Generation, LLC, Three Mile Island Nuclear Station, Unit 1 - NRC Inspection Report No. 07200077/2024001 ML24157A3672024-06-13013 June 2024 Updated Post-Shutdown Decommissioning Activities Report Request for Additional Information Transmittal Letter ML24135A1972024-06-13013 June 2024 – Exemption from Select Requirements of 10 CFR Part 73 (EPID L-2023-LLE-0091 (Security Notifications, Reports, and Recordkeeping and Suspicious Activity Reporting)) ML24151A6482024-06-0303 June 2024 Changes in Reactor Decommissioning Branch Project Management Assignments for Some Decommissioning Facilities ML24120A3242024-05-24024 May 2024 TMI-2 Email to Fws RS-24-055, 2023 Corporate Regulatory Commitment Change Summary Report2024-05-17017 May 2024 2023 Corporate Regulatory Commitment Change Summary Report ML24121A2472024-04-29029 April 2024 And Three Mile Island, Unit 2 - 2023 Occupational Radiation Exposure Annual Report ML24120A2552024-04-29029 April 2024 Annual Radiological Environmental Operating Report ML24113A0212024-04-18018 April 2024 (TMI-2), Supplement to Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation RS-24-002, Constellation Energy Generation, LLC - Annual Property Insurance Status Report2024-04-0101 April 2024 Constellation Energy Generation, LLC - Annual Property Insurance Status Report ML24092A0012024-03-28028 March 2024 (TMI-2), Decommissioning Trust Fund Annual Report ML24065A0042024-03-28028 March 2024 Submittal of 2023 Aircraft Movement Data Annual Report ML24088A0122024-03-28028 March 2024 Notification of Amended Post-Shutdown Decommissioning Activities Report (PSDAR) in Accordance with 10 CFR 50.82(a)(7), Revision 6 ML24085A2152024-03-25025 March 2024 (TMI-2) - Annual Notification of Property Insurance Coverage RS-24-023, Report on Status of Decommissioning Funding.2024-03-22022 March 2024 Report on Status of Decommissioning Funding. ML24052A0602024-03-20020 March 2024 – Exemption from Select Requirements of 10 CFR Part 73 (EPID L-2023-LLE-0061 (Security Notifications, Reports, and Recordkeeping and Suspicious Activity Reporting)) ML24074A3922024-03-14014 March 2024 Response to Request for Additional Information for the TMI-2 Post-Shutdown Decommissioning Activities Report, Rev. 5 ML24075A0062024-03-14014 March 2024 List of Threatened and Endangered Species That May Occur in Your Proposed Project Location or May Be Affected by Your Proposed Project ML24073A2312024-03-13013 March 2024 And Three Mile Island Nuclear Station, Unit 2 - Management Change ML24044A0092024-02-12012 February 2024 License Amendment Request – Three Mile Island, Unit 2, Historic and Cultural Resources Review, Response to Request for Additional Information IR 05000320/20230042024-02-0707 February 2024 TMI-2 Solutions, LLC, Three Mile Island Nuclear Station, Unit 2 - NRC Inspection Report 05000320/2023004 ML24038A0222024-02-0505 February 2024 Achp Letter on Section 106 Programmatic Agreement Participation IR 05000289/20230062024-01-29029 January 2024 Constellation Energy Generation, LLC, Three Mile Island Nuclear Station, Unit 1 - NRC Inspection Report No. 05000289/2023006 ML23342A1242024-01-0909 January 2024 Independent Spent Fuel Storage Installation Security Inspection Plan ML23325A1092024-01-0505 January 2024 Review of the Management Plan for Three Mile Island Station, Unit No. 2, Debris Material ML23354A2062023-12-20020 December 2023 (TMI-2), Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation ML23354A2112023-12-20020 December 2023 Response to Request for Additional Information for the TMI-2 Post-Shutdown Decommissioning Activities Report, Rev. 5 IR 05000320/20230032023-11-28028 November 2023 TMI-2 Solutions, LLC, Three Mile Island Nuclear Station, Unit 2, NRC Inspection Report No. 05000320/2023003 ML23243A9082023-08-29029 August 2023 SHPO Letter to TMI-2 Regarding Section 106 Activities IR 05000320/20230022023-08-17017 August 2023 TMI-2 Solutions, LLC, Three Mile Island Nuclear Station, Unit 2 - NRC Inspection Report 05000320/2023002 ML23216A1782023-08-14014 August 2023 Consultation Letter to Steve Letavic for TMI-2 IR 05000289/20230052023-08-14014 August 2023 Constellation Energy Generation, LLC, Three Mile Island Nuclear Station, Unit 1 - NRC Inspection Report 05000289/2023005 ML23216A1772023-08-14014 August 2023 Consultation Letter to Rebecca Countess for TMI-2 ML23216A1732023-08-14014 August 2023 Consultation Letter to Christine Turner for TMI-2 ML23216A1742023-08-14014 August 2023 Consultation Letter to David Morrison for TMI-2 ML23216A1752023-08-14014 August 2023 Consultation Letter to Joanna Cain for TMI-2 ML23221A1402023-08-0808 August 2023 (TMI-2), Response to Requests for Additional Information for the TMI-2 Post-Shutdown Decommissioning Activities Report, Rev. 5 ML23213A2342023-08-0101 August 2023 Submittal of Defueled Safety Analysis Report and Decommissioning Quality Assurance Plan ML23200A1882023-07-31031 July 2023 TMI-2 Correction Letter Amendment 67 ML23209A7632023-07-28028 July 2023 Letter from PA SHPO to TMI-2 Solutions on Cultural and Historic Impacts of Decommissioning ML23192A8272023-07-10010 July 2023 TMI-2 Solutions, LLC - Response to SHPO Request for Additional Information for Er Project 2021PR03278.006, TMI-2 Decommissioning Project ML23167A4642023-07-0505 July 2023 Letter - TMI-2- Exemption 10 CFR Part 20 Append G Issuance 2024-09-09
[Table view] |
Text
UNITED STATES ber 19, 2007
SUBJECT:
INSPECTION 05000320/2007007, GPU NUCLEAR, THREE MILE ISLAND UNIT 2, MIDDLETOWN, PENNSYLVANIA
Dear Mr. Leidich:
The NRC has completed an announced inspection at your Middletown, PA facility, which covered an inspection period that began on May 31, 2007, and concluded on August 30, 2007.
The preliminary findings of the inspection were discussed with Mr. David Petro and other members of your staff upon the conclusion of the site inspection on May 31, 2007. Additional information provided on June 26 and August 23, 2007 was reviewed, and a summary of the inspection findings for the entire inspection period was discussed with Mr. Petro and other members of your staff during a telephone exit meeting on August 30, 2007. The enclosed report presents the results of that inspection.
Your programs for Post-Defueling Monitored Storage, corrective actions, occupational exposure controls, radiological environmental monitoring, and radioactive effluent controls were reviewed during this period. The inspector reviewed selected procedures and records, interviewed personnel, and observed activities. Within the scope of this inspection, no violations were identified.
In accordance with Section 2.390 of the NRCs Rules and Practices, Part 2, Title 10, Code of Federal Regulations, a copy of this letter and its enclosure will be placed in the NRC Public Document Room (PDR) and will be accessible from the NRC Web site at http://www.nrc.gov/NRC/ADAMS/index.html. No response to this letter is required.
Sincerely,
/RA/
Raymond Lorson, Chief ber 19, 2007
SUBJECT:
INSPECTION 05000320/2007007, GPU NUCLEAR, THREE MILE ISLAND UNIT 2, MIDDLETOWN, PENNSYLVANIA
Dear Mr. Leidich:
The NRC has completed an announced inspection at your Middletown, PA facility, which covered an inspection period that began on May 31, 2007, and concluded on August 30, 2007.
The preliminary findings of the inspection were discussed with Mr. David Petro and other members of your staff upon the conclusion of the site inspection on May 31, 2007. Additional information provided on June 26 and August 23, 2007 was reviewed, and a summary of the inspection findings for the entire inspection period was discussed with Mr. Petro and other members of your staff during a telephone exit meeting on August 30, 2007. The enclosed report presents the results of that inspection.
Your programs for Post-Defueling Monitored Storage, corrective actions, occupational exposure controls, radiological environmental monitoring, and radioactive effluent controls were reviewed during this period. The inspector reviewed selected procedures and records, interviewed personnel, and observed activities. Within the scope of this inspection, no violations were identified.
In accordance with Section 2.390 of the NRCs Rules and Practices, Part 2, Title 10, Code of Federal Regulations, a copy of this letter and its enclosure will be placed in the NRC Public Document Room (PDR) and will be accessible from the NRC Web site at http://www.nrc.gov/NRC/ADAMS/index.html. No response to this letter is required.
Sincerely,
/RA/
Raymond Lorson, Chief Decommissioning Branch Division of Nuclear Materials Safety Docket No. 05000320 License No. DPR-73 Distribution w/encl: R. Bellamy, DRP R. Laufer, RI OEDO B. Watson, FSME S. Collins, RA S. Barber, DRP P. Bamford, PM, NRR K. Banovac, FSME M. Dapas, DRA D. Kern, DRP, Senior E. Miller, NRR, Backup ROPreports@nrc.gov B. Holian, DNMS Resident Inspector J. Lubinski, NRR Region I Docket D. Lew, DRP J. Brand, DRP, RInspector H. Chernoff, NRR J. Clifford, DRP C. LaRegina, DRP, Res.OA D. Persinko, FSME DOCUMENT NAME: C:\FileNet\ML072920094.wpd SUNSI Review Complete: LKauffman After declaring this document An Official Agency Record it will be released to the Public.
To receive a copy of this document, indicate in the box: C = Copy w/o attach/encl E = Copy w/ attach/encl N = No copy OFFICE DNMS/RI E DRP /RI DNMS/RI NAME LKauffman RBellamy RLorson DATE 10/18/07 10/18/07 10/18/07 OFFICIAL RECORD COPY ML072920094
Enclosure:
NRC Region I Inspection Report No. 05000320/2007007 w/Attachment Supplemental Information
REGION I==
Inspection No. 05000320/2007007 Docket No. 05000320 License No. DPR-73 Licensee: Three Mile Island Station, Unit 2 (TMI-2)
Location: P.O. Box 480 Middletown, Pennsylvania 17057-0191 Inspection Dates: May 31, 2007 Date Followup Information Received: June 26 and August 23, 2007 Inspector: Laurie A. Kauffman, Health Physicist Approved By: Raymond Lorson, Chief Decommissioning Branch Division of Nuclear Materials Safety i Enclosure
SUMMARY OF FINDINGS
IR 05000320/2007007; May 31, June 26, and August 23; Three Mile Island Station, Unit 2,
SAFESTOR Inspection.
The report covered an announced inspection related to the Post-Defueling Monitored Storage (PDMS) program, corrective actions, occupational exposure controls, radiological environmental monitoring, and radioactive effluent controls. The inspection was conducted by a regional inspector and was based upon Manual Chapter (MC) 2561, Decommissioning Power Reactor Inspection Program. This routine inspection included a review of PDMS activities related to the safe storage of radioactive material and the implementation of the Unit 2 Technical Specifications (TS). The inspection focused on implementation of the TS requirement to perform an annual surveillance of the exclusion area barriers and accessible areas within the exclusion areas. The inspector determined that the licensee had an adequate program for the safe storage of radioactive material and the implementation of the TS requirement to perform an annual surveillance of the exclusion area barriers and accessible areas within the exclusion areas.
NRC Identified and Self-Revealing Findings
Cornerstone: Radiation Safety
No findings of significance were identified.
Licensee-Identified Violations
None ii
REPORT DETAILS
4OA5 Other Activities
a. Inspection Scope
The inspector evaluated the TMI-2 corrective action program to assess the licensees ability to identify, resolve, and prevent recurrence of conditions and issues that could degrade the safety or quality of PDMS activities. The inspector examined selected issue reports (IRs) and action reports (ARs) and conducted interviews with personnel familiar with the selected issues.
b. Observations and Findings
No findings of significance were identified. The licensee maintained an adequate corrective action program to identify and resolve issues.
.2 IP 83750 and 84750 - Plant Support - 2 samples
a. Inspection Scope
The inspector reviewed PDMS activities related to the safe storage of radioactive material and the implementation of primary containment isolation requirements, TS 3/4.1, Containment Systems. The inspection included site tours and observations of the licensees annual reactor building entry surveillance test (ST). The reactor building ST included activities such as: conducting radiological surveys; water and air sampling; exchanging and analyzing the reactor building breather (passive air flow diaphragm); monitoring and sampling any potential radioactive gaseous effluent through the reactor building purge exhaust; and, collecting liquid samples from the reactor building sump.
The inspector also evaluated aspects of the occupational radiation protection program, radioactive effluent monitoring program, and the radiological environmental monitoring program. The inspector reviewed the related implementing procedures and associated surveillance test results, and the radioactive liquid and radioactive gaseous effluent release permits and data, from January 2006 through May 2007.
b. Observations and Findings
No findings of significance were identified. The inspector determined that the licensee had an adequate program for the safe storage of radioactive material and the implementation of the TS requirement to perform an annual surveillance of the exclusion area barriers and accessible areas within the exclusion areas.
4OA6 Meetings, Including Exit
Exit Meeting Summary
On August 30, 2007, the NRC inspector presented the inspection results to Mr. Petro.
The inspector confirmed that proprietary and safeguards information were not included in this inspection report.
- Supplemental Information
SUPPLEMENTAL INFORMATION
KEY POINTS OF CONTACT
GPU Nuclear Three Mile Island, Unit 2 and Exleon/AmerGen Three Mile Island, Unit 1
- J. Bowers, Radiation Protection Engineer, ALARA Analyst
- R. Crawford, Radiation Waste Operator
- E. A. Curry, Supervisor, TMI-2, GPUN
- E. Parido, Radiation Protection Technician, TMI-1, AmerGen
- D. Petro, Responsible Engineer, TMI-2; Senior Consultant, First Energy Nuclear
Operating Company (FENOC)
- D. Smith, PDMS Manager, Work Management, TMI-1, AmerGen
- C. Wend, Radiation Protection Manager
- G. Welsh, Senior Mechanical Maintenance Technician
LIST OF ITEMS
OPENED, CLOSED AND DISCUSSED
OPEN NONE CLOSED NONE DISCUSSED NONE
LIST OF DOCUMENTS REVIEWED