IR 05000288/2009201
| ML093570003 | |
| Person / Time | |
|---|---|
| Site: | Reed College |
| Issue date: | 12/23/2009 |
| From: | Johnny Eads Research and Test Reactors Branch B |
| To: | Frantz S Reed College |
| Bassett C, NRR/DRP/PRTB, 404-562-4899 | |
| References | |
| IR-09-201 | |
| Download: ML093570003 (19) | |
Text
December 23, 2009
SUBJECT:
REED COLLEGE - NRC ROUTINE INSPECTION REPORT NO.
50-288/2009-201
Dear Mr. Frantz:
On November 30 - December 3, 2009, the U.S. Nuclear Regulatory Commission (NRC, the Commission) conducted an inspection at your Reed Reactor Facility (Inspection Report No.
50-288/2009-201). The enclosed report documents the inspection results which were discussed with you on December 3, 2009.
The inspection examined activities conducted under your license as they relate to safety and compliance with the Commissions rules and regulations and with the conditions of your license.
The inspector reviewed selected procedures and records, observed activities, and interviewed personnel. Based on the results of this inspection, no findings of significance were identified.
No response to this letter is required.
In accordance with Title 10 of the Code of Federal Regulations Section 2.390, Public inspections, exemptions, and requests for withholding, a copy of this letter, its enclosure, and your response (if any) will be available electronically for public inspection in the NRC Public Document Room or from the NRCs document system (Agencywide Documents Access and Management System (ADAMS)). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).
Should you have any questions concerning this inspection, please contact Craig Bassett at (404) 358-6515 or by electronic mail at Craig.Bassett@nrc.gov.
Sincerely,
/RA By Paul V. Doyle Acting For/
Johnny H. Eads, Chief Research and Test Reactors Branch B Division of Policy and Rulemaking Office of Nuclear Reactor Regulation
Docket No. 50-288 License No. R-112
Enclosure: NRC Inspection Report 50-288/2009-201 cc w/encl.: Please see next page
Reed College Docket No. 50-288
cc:
Mayor of the City of Portland 1220 Southwest 5th Avenue Portland, OR 97204
Reed College ATTN: Dr. Peter Steinberger Dean of Faculty 3203 S.E. Woodstock Boulevard Portland, OR 97202-8199
Reed College ATTN: Dr. Colin Diver President 3203 S.E. Woodstock Boulevard Portland, OR 97202-8199
Oregon Department of Energy ATTN: David Stewart-Smith, Director Division of Radiation Control 625 Marion Street, N.E.
Salem, OR 97310
Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611
December 23, 2009 Mr. Stephen