APPENDIX U.S. NUCLEAR REGULATORY COMMISSION
REGION IV
Inspection Report:
50-262/92-01 Operating License: R-109 Licensee:
Brigham Young University Provo, Utah 84602 Facility Name:
L-77 Research Rr;ctor Facility
.
Inspection At:
Provo, Utah Inspection Conducted:
November 30 through December 1, 1992 Inspector:
A. D. Gaines, Radiation Specialist Facilities Inspection Programs Section Approved:
M
[b/ldW Y
L 3. Murray, Chief, Facilit is inspection Da'te'
Programs Section Inspection Summary Areas Inspected:
Routine, announced inspection of the radiation protection program as it pertained to the decommissioning of the reactor.
Results:
Proper personnel monitoring was provided for personnel involved with e
decommissioning activities (paragraph 1.2.1),
Radiation and contamination surveys were properly performed and e
documented (paragraph 1.2.2).
Proper calibration and quality control checks were performed on e
radiation detection instrumentation (paragraph 1.2.3),
Areas were correctly posted and controlled (paragraph 1.2.4).
o Proper 10 CFR 19.12 instructions were provided for radiation workers e
(paragraph 1.2.5).
The Decommissioning Committee provided proper oversight of e
decommissioning activities (paragraph 1.3).
$$k2Q@gy o$$
2-G
'
. -
.
-
-
. - -.
.
- - _ _
-_.
_.
.._.
_. _.
i i
.
-2-Summary of Inspection Findinas:
e No violations or deviations were identified.
Attachment:
Attachment 1 - Persons Contacted and Exit Meeting
,
i i
--
,
r
.
.
-3-DETAILS 1 CLASS 11 NON-POWER REACTORS (40750)
The licensee's program was inspectsd to determine compliance with 10 CFR Parts 19 and 20, and agreement with the Order Approving Decommissioning Plan and Authorizing Cacommissioning issued July 23, 1992.
1.1 Backoround The L-77 Research Reactor was last operated on May 11, 1982. The reactor was defueled on May 5,1987, and the fuel shipped to the Idaho National Engineering Laboratory. An Order Approving Decommissioning Plan and Authorizing Decommissioning - was issued JJ1y 23, 1992.
On October 20, 1992, the licensee's Decommissioning Committee gave approval to remove shielding water and cut up the shield assembly to remove the core vessel. The licensee had cut up the shield assembly and placed the core vessel in a 55 gallon drum which was stored in the licensee's radioactive waste storage facility. The licensee had packaged some of the radioactive waste from decommissioning, but none of the waste had been shipped offsite for disposal. The next decommissioning activities include further cleanup of the facility, removal of material and equipment, and a final radiation survey.
The licensee expects to have the final radiation survey completed by January 31, 1993.
1.1 0roanizational Chanaes The inspector reviewed the licensee's decommissioning organizational structure and noted that it conformed to their NRC-approved decommissioning plan.
1.2 Health physics 1.2.1 Personnal Monitoring The licensee used vendor-supplied personnel dosimetry for all personnel involved in decommissioning activities. Personnel monitoring results for the period when decommissioning activities were performed had not been received from the vendor at the time of this inspection.
1.2.2 Radiation Surveying, Sampling, and Monitoring The inspector reviewed selected radiation and contamination surveys perfermed during decommissioning activities. The licensee had performed the necessary surveys to doc uent radiation and contamination levels prior-to and during various work activities.
Survey records contained all required information.
The inspector performed radiation surveys of the nuclear reactor butiding.
The licensee was not finished with decommissioning activities and, therefore, had not performed a final radiation survey. The inspector's surveys were performed to independently verify facility radiological condition at the time of this inspection. The radiological surveys performed included direct
_
_
.
, _ _
J
_ _ _ _ _ - _ - _ _ - - _ _ _ _ _ _ - _ _ _ _.
'
.
.
-4-
.
measurements of beta and gamma radiation levels. Measurements of removable
~
and nonremovable alpha and beta contamination were also made.
The inspector determined that the general background direct gamma radiation lavels associated with the facility were 8 to 10 micro Roentgen per hour
-
eR/hr).
Some of the walls had background levels of 12 to 14 pR/hr. The b spector identified two localized " hot spots". One small area on the wa by ia electrical junction box was approximately 180 pR/hr, the other area was on a lab bench and was approximately 200 pR/hr.
The Radiation Safety Officer was with the inspector during the surveys and noted the areas for further review.
No areas were identified that were above the background levels for fixed beta radiation.
-
The inspector performed surveys to identify removable alpha and be'
contamination using conventional paper smear techniques.
Emear su.veys were taken over a nominal 100 square centimeters and analyzed or alpha and beta radioactivity. The smears were taken on the floor where the reactor had been located. No removable radioactive contamination levels above background levels were identified.
j 1.2.3 Radiological Monitoring Instrumentation Calibration The licensee contracted with a radiation survey instrument vendor to calibrate the survey instruments used for decommissioning surveys. The inspector verified through records review that instruments were properly calibrated and that the licenset performed the appropriate quality control checks on the instruments as required in the decommissioning plan.
1.2.4 Posting The inspector verified that notices to workers were properly posted in a sufficient number of places to permit workers to observe them.
1.2.5 Instruction of Workers L
aterial provided to individuals who worked The inspector reviewed the sogr: 0 on decommissioning activities.
ne t;terial was presented as part of the 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> of radiation and safety training session that workers who had no previous training had to complete prior to working on decommissioning activities.
lae material adequateif cover the topics required by 10 CFR 19.12.
1.'
Committee. Audits, and Reviews The inspector reviewed Decommiss oning Committee meeting minutes and d
de ommissioning activity sheets.
The inspector noted that the minutes and activity sheets indicated that t-Decommissioning Committee was informed of and *eviewed all decommissioning civities as required in the decommissioning plar.
.
__
_ _ _ _ __ _ - _ _ - - _ - _ - _ _ _ _ ___ _ _ _-_____
_ _ _ _ _ _ _ _ _ _ _ -
k
.
,.
-5-1,4 Conclusions
- Proper personnel monitoring was provided for personnel involved with decommissioning activities.
Radiation and contamination surveys were properly performed and documented.
Proper calibration and quality control checks were performed on radiation detection instrumentation.-
Areas were correctly posted and controlled.
Proper 10 CFR 19.12 instructions were provided for radiation workers.
The Decommissioning Committee provided proper oversight of decommissioning activities.
.
k
r-
.
.
-. -
ATTACHMENT 1 1 PERSONS CONTACTED 1.1 Licensee Personnel
- E. F. Jackson, Radiation Safety Officer
- F. W. Nelson, Safety Director C. E. Pugh, Chemical Hygiene Officer
- Cenotes personnel that attended the exit meeting.
2 EXIT MEETING An exit meeting was conducted on December 1,1992. During this meeting, the inspector reviewed the scope and findings of the report.