NOV14 1939
-
Docket No. 030-19799 6O~
Kcaai Peninsula Borough 144 N. Binkley Street Soldotna, Alaska 99699 Attention:
Mr. Ken Brown Director of Public Works Gentlemen:
Thank you for your letter dated October 18, 1988 informing us of the steps you have taken to correct items which we brought to your attention in our letter dated September 9, 1988.
Your corrective actions will be verified during our next inspection.
We do not agree with your comment in Paragraph B of your letter which states that conducting the leak test of the sources satisfies the physical inventory requirement.
The purpose of the physical inventory requirement is to ensure that a licensee is fully aware of the location of each source / gauge which is in his possession.
For example, a licensee may have several gaugss in his possession which are distributed at a number of field sites, and simply conducting a leak test does not fulfill the inventory requirement.
Physical inventory records must include the specific location of the source / gauge at the ?.ime that the inventory was conducted as well as other required information such as quantities and kinds of byproduct material, date of inventory, make and model of the gauge or source, and serial numbers.
For these reasons, the violation regarding physical inventories (Appendix A, Violation B) is a valid citation.
Your cooperation with us is appreciated.
Sincerely, l
I(10 l f18 Ross A. Scarano, Director Division of Radiation Safety and Safeguards 0811230333 001114 REG 5 LIC30 PNU l
50-21114-01
-
.
.
.
NOV 141988
.
.g.
.
bec w/ copy of letter dated 10/18/88:
Docket File G. Cook B. Faulkenberry J. Martin LFM8 State of Alaska bec w/o copy of letter dated 10/18/88:
M. Smith
REGION V
.g JFPang/Joan RT@ ias RAScarano 11/p/88 11/////
11/'l/88
/
,, REQUEST COPY ] REQUEST Y ] REQU'
CO
]
'Y ES '/ NO
] YES /
] YE
/
]
('J V
yS / NO j
[