October 1, 2009
Dr. T. Tehan, Director Rhode Island Nuclear Science Center Rhode Island Atomic Energy Commission 16 Reactor Road Narragansett, RI 02882-1165
SUBJECT:
RHODE ISLAND ATOMIC ENERGY COMMISSION - NRC ROUTINE
INSPECTION REPORT NO. 50-193/2009-202
The U.S. Nuclear Regulatory Commission (NRC, the Commission) conducted an inspection on September 14-17, 2009, at the Rhode Island Nuclear Science Center Reactor facility (Inspection Report No. 50-193/2009-202). The inspection included a review of activities authorized for your facility. The enclosed report presents the results of that inspectio This inspection was an examination of activities conducted under your license as they relate to safety and compliance with the Commissions rules and regulation Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations of activities in progress. Based on the results of this inspection, no safety concern or noncompliance of requirements was identified. No response to this letter is require In accordance with Title 10 of the Code of Federal Regulations 2.390 Inspections, examinations, requests for withholding, a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or the NRCs document system (Agencywide Document Access and Management System (ADAMS)). ADAMS is accessible from the NRC Web site at (the Public Electronic Reading Room)
http://www.nrc.gov/reading-rm/adams.htm Should you have any questions concerning this inspection, please contact Jack Donohue at 301-415-3163 or electronic mail at Jack.Donohue@nrc.go
Sincerely,
/RA/
Johnny H. Eads, Chief Research and Test Reactors Branch B Division of Policy and Rulemaking Office of Nuclear Reactor Regulation
Docket N License N R-95
Enclosure: As stated
cc w/ encl: See next page
Rhode Island Atomic Energy Commission
Docket No.: 50-193
cc:
Governor Donald Carcieri State House Room 115 Providence, RI 02903
Dr. Stephen Mecca, Chairman Rhode Island Atomic Energy Commission Providence College Department of Engineering-Physics Systems River Avenue Providence, RI 02859
Dr. Harry Knickle, Chairman Nuclear and Radiation Safety Committee University of Rhode Island College of Engineering 112 Crawford Hall Kingston, RI 02881
Dr. Andrew Kadak 253 Rumstick Road Barrington, RI 02806
Dr. Bahram Nassersharif Dean of Engineering University of Rhode Island 102 Bliss Hall Kingston, RI 20881
Dr. Peter Gromet Department of Geological Sciences Brown University Providence, RI 02912
Dr. Alfred L. Allen 425 Laphan Farm Road Pascoag, RI 02859
Mr. Jack Ferruolo, Supervising Radiological Health Specialist Office of Occupational and Radiological Health Rhode Island Department of Health 3 Capitol Hill, Room 206 Providence, RI 02908-5097
Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611 Dr. T. Tehan, Director
October 1, 2009 Rhode Island Nuclear Science Center Rhode Island Atomic Energy Commission 16 Reactor Road Narragansett, RI 02882-1165
SUBJECT:
RHODE ISLAND ATOMIC ENERGY COMMISSION - NRC ROUTINE
INSPECTION REPORT NO. 50-193/2009-202
The U.S. Nuclear Regulatory Commission (NRC, the Commission) conducted an inspection on September 14-17, 2009, at the Rhode Island Nuclear Science Center Reactor facility (Inspection Report No. 50-193/2009-202). The inspection included a review of activities authorized for your facility. The enclosed report presents the results of that inspectio This inspection was an examination of activities conducted under your license as they relate to safety and compliance with the Commissions rules and regulation Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations of activities in progress. Based on the results of this inspection, no safety concern or noncompliance of requirements was identified. No response to this letter is require In accordance with Title 10 of the Code of Federal Regulations 2.390 Inspections, examinations, requests for withholding, a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or the NRCs document system (Agencywide Document Access and Management System (ADAMS)). ADAMS is accessible from the NRC Web site at (the Public Electronic Reading Room)
http://www.nrc.gov/reading-rm/adams.htm Should you have any questions concerning this inspection, please contact Jack Donohue at 301-415-3163 or electronic mail at Jack.Donohue@nrc.go
Sincerely,
/RA/
Johnny H. Eads, Chief Research and Test Reactors Branch B Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket N License N R-95
Enclosure: As stated cc w/ enclosure:
See next page
DISTRIBUTION:
PUBLIC PRTB/rf RidsNrrDprPrtb
RidsOgcMailCenter JDonohue, NRR WKennedy, NRr MCompton, NRR (Ltr only O13-E19)
GLappert, NRR RidsNrrDprPrta ADAMS ACCESSION NO.: ML092710005 TEMPLATE #: NRC-002 OFFICE PRT:RI PRT:LA PRT:BC NAME JDonohue jd GLappert gkl JEads jhe DATE 7/25/09 9/30/09 10/1/09 OFFICIAL RECORD COPY
U. S. NUCLEAR REGULATORY COMMISSION
OFFICE OF NUCLEAR REACTOR REGULATION
Docket No:
50-193
License No:
R-95
Report No:
50-193/2009-202
Licensee:
Rhode Island Atomic Energy Commission
Facility:
Rhode Island Nuclear Science Center Research Reactor
Location:
Narragansett, Rhode Island
Dates:
September 14 - 17, 2009
Inspector:
Jack Donohue
Approved by:
Johnny H. Eads, Chief Research and Test Reactors Branch B Division of Policy and Rulemaking Office of Nuclear Reactor Regulation
EXECUTIVE SUMMARY
Rhode Island Atomic Energy Commission Rhode Island Nuclear Science Center Reactor Facility NRC Inspection Report No. 50-193/2009-202
The primary focus of this routine, announced operations inspection was the onsite review of selected aspects of the Rhode Island Atomic Energy Commission (the licensees) two megawatt Class I research reactor safety programs including organization and staffing, operations and maintenance; surveillance; fuel movement; reactor operator licenses, requalification and medical examinations; and emergency preparednes The licensees programs were acceptably directed toward the protection of public health and safety, and in compliance with U. S. Nuclear Regulatory Commission (NRC) requirement Organization and Operations and Maintenance Activities
Organization, operations, and maintenance were observed to be in accordance with Technical Specification (TS) requirement The licensee was actively monitoring expectations for continued improvement of communications and for maintaining a safety conscious work environment within the staf Surveillance
Operations were found to be in compliance with the limiting conditions for operation and surveillance requirements as stated in the T Fuel Movement
The licensee made very infrequent reactor fuel movements but when required, followed written procedures that met TS requirement Reactor Operator Licenses, Requalification and Medical Examinations
The licensee was conducting a reactor operator re-qualification program in compliance with NRC regulations and the licensees written progra Emergency Preparedness
The licensee maintained an effective emergency preparedness program through implementation of the written emergency pla REPORT DETAILS
Summary of Facility Status
The Rhode Island Atomic Energy Commissions (RIAEC, the licensee) Rhode Island Nuclear Science Center (RINSC) two megawatt Class I research reactor continued to be operated in support of research, service, education, training, and surveillanc During the inspection, the inspector observed the reactor in operation to irradiate samples as part if its research and service missio.
Organization and Operations and Maintenance Activities Inspection Scope (Inspection Procedure (IP) 69006
The inspector reviewed the following regarding the licensee's organization and staffing to ensure that the requirements of Section 6.0, Administrative Controls, of the RINSC Technical Specifications (TS), Amendment No. 29 to License N R-95 was being met:
- Reactor Logbook No. 56, dated April 4, 2008 to June 11, 2009 and Logbook No. 57, dated June 17, 2009 to present
Annual Report for July 1, 2008 through June 30, 2009, dated July 31, 2009
Standard Operating Procedures
RINSC organizational structure and staffing
Policy Statement, Safety Conscious Work Environment, Issued by the Rhode Island Atomic Energy Commission
Rhode Island Atomic Energy Commission (RIAEC) meeting minutes, dated August 7, 2009 Observations and Findings
The inspector observed a reactor checkout, startup, approach to critical, escalation to full power, and a typical sample irradiatio The inspector reviewed portions of the reactor logbook, verifying compliance with the staffing requirements of TS Sections 6.1.2 and 6.1.3 and that the NRC-licensed Reactor Operator (RO) and Senior Reactor Operator (SRO) on duty were designated by name in the reactor logboo These individuals executed their duties in accordance with TS Sections 6.3.2, Senior Reactor Operators; 6.3.3, Reactor Operators; 6.5, Operating Procedures; and 6.9, Plant Operating Record The inspector noted a change in key licensee personne Mr. E. Wentz had resigned as Assistant Director for Reactor Operations, and was replaced by M M. J. Davis appointed as Assistant Director for Operation Mr. B. MacGregor has been named as Reactor Supervisor succeeding Mr. M. J. Davis. The inspector discussed with licensee management and reaffirmed the importance of
- 2 -
anticipating the replacement of key staff members who are approaching retirement and/or otherwise not suite The inspector additionally noted that RINSC procedures have been going through a systematic revision and update proces The original facility procedures were numbered one through thirteen, and each procedure covered a series of task As new procedures were needed, they were added as appendices to the original thirteen procedure A new numbering system has been developed and approved by the Nuclear and Radiation Safety Committee (NRSC). Under this system, procedures are grouped according to whether they are operating procedures, test procedures, calibration procedures, et As the procedures are updated, they are being put into a uniform standard format that was also approved by the NRS All new procedures and procedure revisions are submitted to the NRSC for review and approval quarterl Once approved, the staff is informed about the changes, and the procedures are incorporated into the Procedure History Record, the shared hard drive file for current procedures, and the control room procedure notebook. The Procedure Index is also updated to indicate the current list of procedures, as well as the latest revision in us The inspector discussed with licensee management the status of aspects of a chilled work environment addressed in letters dated December 27, 2007 and March 11, 200 The licensee staff personnel indicated communication among RINSC staff members has improved, a result, in part, of weekly staff meetings called by the Directo The RIAEC was actively monitoring the RINSC environment relative to their expectations for a safety conscious work environmen Conclusions
Organization, operations, and maintenance were observed to be in accordance with TS requirement The licensee was actively monitoring expectations for continued improvement of communications and for maintaining a safety conscious work environment within the staf.
Surveillance Inspection Scope (IP 69010)
The inspector reviewed the following to verify compliance with TS Section 3.0, Limiting Conditions for Operation, and to determine if the periodic surveillance tests on safety systems were performed as stipulated in TS Section 4.0, Surveillance Requirements:
- RINSC Reactor Operating Data Notebook, 2008 and 2009
Periodic Maintenance Notebook containing the documentation of maintenance items
RINSC Operating Procedure Appendix M, Determining Blade Worth and Insertion Rates, dated January 29, 1999
- 3 -
RINSC Operating Procedure Appendix F, Inspection of Reactor Pool and Suspension Frames, dated August 24, 1995
RINSC Operating Procedure Appendix D, Blade Speeds and Drop Times, Rev. 1, dated March 28, 2003
Technical Specification 4.9.a, Beryllium Reflector [Annual Inspection]
Reactor Operations Request NSC-49, Pre-Start Check Sheet NCS-1, Shift Record Data Sheet NSC-11, and RINSC Reactor Operations Data NSC-18 for 2008 and 2009 Observations and Findings
The inspector witnessed a reactor startup, approach to critical and ascension to power, observing the completion and documentation of numerous TS surveillances and compliance with TS limiting conditions for operation (LCO).
This was accomplished through adherence to written procedures which had been reviewed by the NRSC in accordance with TS Section 6.3, Operating Procedure Additional records for the surveillances cited above were also reviewed including: beam port inspection (October 27, 2008), pool inspection, shim blade drop time (August 3, 2009), cold clean blade reactivity (August 12, 2009), control blade reactivity worths (August 29, 2009). Conclusions
Operations were found to be in compliance with the LCO and surveillance requirements as stated in the T.
Fuel Movement Inspection Scope (IP 69009)
The inspector reviewed the following to verify compliance with TS Sections 4. and 6.9.1.g which require inspection of fuel elements every 5 years and maintaining operating records of the fuel inventory, respectively:
- Reactor Logbook No. 56, April 4, 2008 - June 11, 2009 and Reactor Logbook No. 57, June 17, 2009 to present
Annual Report for July 1, 2008 through June 30, 2009, dated July 31, 2009
Standard Operating Procedures
RINSC Operating Procedure Appendix Z, [Special Nuclear Material] SNM Accounting, Rev. 5, for inventory taken October 22, 2007
RINSC Operating Procedure Appendix Z, SNM Accounting, Rev. 6, for inventory taken April 14, 2008
Mr. M. Davis, RINSC to Dr. J. Breen, Nuclear Radiation Safety Committee Chair, RINSC Core Configuration dated August 24, 2009
- 4 - Observations and Findings
During a recent fuel inspection on May 5, 2009, the RINSC staff discovered that the core positions of two fuel elements had been transposed. Following the investigation the staff determined that this transposition had occurred when the two fuel elements were removed from the core and placed into a storage rack to perform a gamma irradiation experiment. Following the experiment the elements were placed back into the core in the reversed locations. The elements were reinstalled in the pool maintaining ALARA considered prior to validation. The most likely cause of the fuel being reinstalled in the incorrect locations is the numbers were misread due to poor lighting and readability in 20 feet of wate The corrective action will be an increase in verification personnel and lighting during validation. Additionally to reduce exposure the fuel will remain in place and the low-enriched uranium (LEU) core No. 4 will be changed to LEU core N. This will make the elemental MWH and fuel build up calculation easier in the future. The NRC was notified on the fuel transposition at the time of the occurrenc Conclusions
The licensee has made infrequent reactor fuel movements and has made additional changes to ensure fuel once removed returns to previous or required locations. The licensee followed written procedures that met TS requirement.
Reactor Operator Licenses, Requalification and Medical Examinations Inspection Scope (IP 69003)
The inspector reviewed the following to verify compliance with Title 10 of the Code of Federal Regulations (10 CFR) Part 55, Operators Licenses, and the licensees reactor operator requalification program:
- RINSC Operating Procedures Appendix U, Reactor Operator Re-Qualification, Revision (Rev.) 2, dated June 29, 2005
Individual RO and SRO Requalification files containing:
NRC Form 396, Certification of Medical Examination by Facility Licensee
Operator Requalification Program Checklist
Medical Certification and Monitoring of Certified Personnel, of Standard ANSI/ANS 15.4, Selection and Training of Personnel for Research Reactors, to use as the basis for determining adequate physical fitness to serve as an SRO or R Observations and Findings
The inspector reviewed the licensees operator requalification program to verify that it met the requirements of 10 CFR Part 55 and reviewed selected licensed RO and SRO files, verifying that the program was being conducted in accordance with the written procedur The annual operating examination and
- 5 -
the biennial written examination were of equivalent difficulty to NRC-administered examinations as require Records were available documenting the fact that during the requalification cycle the individual operators performed the required number of licensed activities and reviewed changes to the facility, regulations, and procedures in addition to passing the examination Medical examinations were also reviewed satisfactorily for selected licensed persona Conclusions
The licensee was conducting a reactor operator requalification program in compliance with NRC regulations and the licensees written progra.
Emergency Preparedness Inspection Scope (IP 69011)
The inspector reviewed the following documents and visited the facilities discussed below to verify compliance with regulatory requirements and the licensees emergency plan commitments:
- Emergency Plan, Rev. 2, dated January 2007
Letter from Mr. M.J. Davis, RINSC to Mr. D. Hughes, NRC, [Transmittal Letter for Revised Emergency Plan], dated March 15, 2007
RINSC Operating Procedure Appendix X, Emergency Plan Implementing Procedures, Rev. 0, dated June 19, 2007, containing:
Attachment B, Form NSC-31, Emergency Communications Network
Attachment E, Emergency Classification Matrix
[Emergency] Communication Tests file
Emergency Equipment Inventory file
Emergency Drill file containing:
Letter from Mr. H. Bicehouse to NRSC, Radiological Emergency Response Plan, dated October 31, 2007
Mr. E. Wentz, Assistant Director of Operations to Dr. S. Mecca Chairman RIAEC from Mr. M. J. Davis, Emergency Drill Critique drill actions items, dated September 26, 2008
Letter of Agreement between Narragansett Police Department and RINSC, signed by Mr. M. J. Davis on December 20, 2007, and by Chief J. Cotter on January 2, 2008
Letter of Agreement for Medical Services, from Mr. A. Cordeiro, Vice President of Rhode Island Hospital, to Mr. T. Tehan, RIAEC, dated February 4, 2008 Observation and Findings
The inspector reviewed the revised emergency plan, including an attachment submitted with the transmittal letter to the NRC explaining why the RINSC staff
- 6 -
and NRSC deemed that the changes did not change the effectiveness of the plan and therefore met the criteria of 10 CFR 50.54(q). The inspector concurred with the licensees conclusions regarding each of the changes reviewe The licensee maintained a file of recent agreement letters with off-site emergency agencies identified in the plan and reissues the agreement bienniall The inspector reviewed previous annual emergency drills for 2007 and 2008 and follow-up action items from the critique The critiques were conducted to review emergency preparedness in general and to identify any weakness or lessons learned from the drills that warranted follow-up action The inspector visited the Narragansett Fire Department and discussed with the Fire Chief, J. Cotter the upcoming emergency drill presently scheduled for September 25, 2009, and their emergency preparedness for the drill including personnel trainin The Fire Chief described their capabilities and relationship with RINSC staf He also indicated their capabilities utilizing three available Fire Stations to support of any radiological emergency event at RINS The inspector visited the Emergency Support Center, observing the inventory of emergency supplies, instruments, and information committed to be housed there by the pla The licensee maintained records indicating that the emergency supplies were periodically inventoried as part of the surveillance program invoked by the emergency plan Conclusions
The licensee maintained an effective emergency preparedness program through implementation of the written emergency pla.
Exit Interview
The inspector presented the inspection results to licensee management at the conclusion of the inspection on September 17, 200 The inspector described the areas inspected and discussed in detail the inspection observation No dissenting comments were received from the license The licensee acknowledged the findings presented and did not identify as proprietary any of the material provided to or reviewed by the inspector during the inspection and that the results of the inspection are subject to management review
PARTIAL LIST OF PERSONS CONTACTED
Licensee
H. Bicehouse Radiation Safety Officer and Assistant
Director for Radiation and Reactor Safety M. Damato
Health Physics Technician and Reactor Operator M.J. Davis
Assistant Director, Rhode Island Nuclear Science Center B. Nassersharif Rhode Island Atomic Energy Commission T. Tehan
Director, Rhode Island Nuclear Science Center C. Waring
Health Physicist J. Cotter
Narragansett Fire Chief
INSPECTION PROCEDURES USED
IP 69003 Class 1 Research and Test Reactor Operator Licenses, Requalification, and Medical Examinations IP 69006 Class 1 Research and Test Reactors Organization and Operations and Maintenance Activities IP 69009 Class 1 Research and Test Reactors Fuel Movement IP 69010 Class 1 Research and Test Reactors Surveillance IP 69011 Class 1 Research and Test Reactors Emergency Preparedness
ITEMS OPENED, CLOSED, AND DISCUSSED
Opened
None
Closed
None
Discussed
50-193/2009-201-01 IFI Reactor Power was logged when reaching the required power level and used to determine the fuel burn-up for the Annual Repor RINSC Staff will continue to investigate a more accurate determinatio LIST OF ACRONYMS USED
ADAMS Agencywide Document Access Management System ALARA As Low As Reasonably Achievable CFR
Code of Federal Regulations IFI
Inspector Follow-up Item IP
Inspection Procedure NRC
U. S. Nuclear Regulatory Commission NRSC Nuclear and Radiation Safety Committee NSC
Nuclear Science Center Rev
Revision RIAEC Rhode Island Atomic Energy Commission RINSC Rhode Island Nuclear Science Center RO
Reactor Operator RSO
Radiation Safety Officer SOP
Standard Operating Procedure SRO
Senior Reactor Operator TS
Technical Specification