IR 05000170/2009202
| ML092600723 | |
| Person / Time | |
|---|---|
| Site: | Armed Forces Radiobiology Research Institute (R-084) |
| Issue date: | 09/28/2009 |
| From: | Johnny Eads Research and Test Reactors Branch B |
| To: | Lillis-Hearne P US Dept of Defense, Armed Forces Radiobiology Research Institute |
| isaac p, j NRC/NRR/DPR/PRTB, 301-415-101 | |
| References | |
| IR-09-202 | |
| Download: ML092600723 (3) | |
Text
September 28, 2009
SUBJECT:
ARMED FORCES RADIOBIOLOGY RESEARCH INSTITUTE - NRC SECURITY INSPECTION REPORT NO. 50-170/2009-202
Dear Colonel Lillis-Hearne:
On September 1-2, 2009, the U. S. Nuclear Regulatory Commission (NRC, the Commission)
conducted a security inspection at your Research Reactor Facility (Inspection Report No. 50-170/2009-202). The inspection included a review of activities authorized for your facility. The enclosed report presents the results of that inspection.
The inspection examined activities conducted under your license as they relate to security and compliance with NRC rules and regulations, and compliance with the conditions of your license.
The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel. Based on the results of this inspection, no safety concerns or non-compliances with NRC requirements were identified. No response to this letter is required.
In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document system (ADAMS). ADAMS is accessible from the NRC Website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). However, because of the security-related items contained in the enclosure, and in accordance with 10 CFR 2.390(d), a copy of this letter=s enclosure will not be available for public inspection.
Should you have any questions concerning this inspection, please contact Patrick J. Isaac at 301-415-1019 or electronic mail at Patrick.Isaac@nrc.gov.
Sincerely,
/RA/
Johnny H. Eads, Jr., Chief Research and Test Reactors Branch B Division of Policy and Rulemaking Office of Nuclear Reactor Regulation
Docket No. 50-170 License No. R-84
Enclosure: As stated
cc w/o encl: See next page Document transmitted herewith contains security related information. When separated from enclosures, this document is decontrolled. Armed Forces Radiobiology Research
Docket No. 50-170
cc:
Director, Maryland Office of Planning 301 West Preston Street Baltimore, MD 21201
Montgomery County Executive 101 Monroe Street, 2nd Floor Rockville, MD 20850
Mr. Stephen I. Miller Reactor Facility Director Armed Force Radiobiology Research Institute 8901 Wisconsin Avenue Bethesda, MD 20889-5603
Environmental Program Manager III Radiological Health Program Air & Radiation Management Adm.
Maryland Dept of the Environment 1800 Washington Blvd.,Suite 750 Baltimore, MD 21230-1724
Rich McLean, Manager Nuclear Programs Maryland Department of Natural Resources Tawes B-3 Annapolis, MD 21401
Director Air & Radiation Management Adm.
Maryland Dept of the Environment 1800 Washington Blvd., Suite 710 Baltimore, MD 21230
Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611
Package: ML092610047 Cover Letter: ML092600725, IR: ML092600755 NRC-002 OFFICE NRR/DPR/PRTB NRR/DPR/PRTB: LA NRR/DPR/PRTB:BC NAME PIsaac pxi GLappert gkl JEads jhe DATE 9/ 17 /2009 9/28/2009 9/28/09