April 24, 2019

SUBJECT:

UNIVERSITY OF WISCONSIN - U.S. NUCLEAR REGULATORY COMMISSION ROUTINE INSPECTION REPORT NO. 50-156/2019-201

Dear Mr. Agasie:

From March 18 - 20, 2019, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at the University of Wisconsin Nuclear Reactor Laboratory. The enclosed report documents the inspection results, which were discussed on March 21, 2019, with you, Corey Edwards, Reactor Supervisor, Dr. Douglass Henderson, Chair of the Engineering Physics Department, and Dr. Paul Wilson, Reactor Safety Committee member.

This inspection examined activities conducted under your license as they relate to safety and compliance with the Commissions rules and regulations and with the conditions of your license.

The inspector observed various activities in progress, interviewed personnel, and reviewed selected procedures and records. Based on the results of this inspection, no findings of significance were identified. No response to this letter is required.

In accordance with Title 10 of the Code of Federal Regulations, Section 2.390, Public Inspections, Exemptions, Requests for Withholding, a copy of this letter, its enclosure, and your response (if any) will be available electronically for public inspection in the NRC Public Document Room or from the NRCs document system (Agencywide Documents Access and Management System (ADAMS)). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). Should you have any questions concerning this inspection, please contact Craig Bassett at 240-535-1842 or by electronic mail at Craig.Bassett@nrc.gov.

Sincerely,

/RA/

Anthony J. Mendiola, Chief Research and Test Reactors Oversight Branch Division of Licensing Projects Office of Nuclear Reactor Regulation

Docket No. 50-156 License No. R-74

Enclosure:

As stated

cc: See next page

University of Wisconsin

Docket No. 50-156

cc:

Mayor of Madison City Hall 210 Martin Luther King Jr. Boulevard Room 403 Madison, Wisconsin 53703

Chairman, Public Service Commission of Wisconsin 610 North Whitney Way Madison, WI 53707-7854

Paul Schmidt, Manager Radiation Protection Section Division of Public Health Wisconsin Dept of Health Services P.O. Box 2659 Madison, WI 53701-2659

Test, Research and Training Reactor Newsletter Attention: Amber Johnson Dept of Materials Science and Engineering University of Maryland 4418 Stadium Drive College Park, MD 20742-2115

Jason Timm, Assistant Director

& Radiation Safety Officer University of Madison - Wisconsin Department Environmental Health & Safety Environmental Protection and Safety Bldg.

30 E. Campus Mall Madison, WI 53715