August 11, 2016

SUBJECT:

UNIVERSITY OF WISCONSIN - U.S. NUCLEAR REGULATORY

COMMISSION ROUTINE INSPECTION REPORT NO. 50-156/2016-202

Dear Mr. Agasie:

From July 18-21, 2016, the U.S. Nuclear Regulatory Commission (NRC or the Commission)

conducted an inspection at the University of Wisconsin Nuclear Reactor Laboratory. The enclosed report documents the inspection results which were discussed on July 21, 2016, with you and the Reactor Supervisor.

This inspection examined activities conducted under your license as they relate to safety and compliance with the Commissions rules and regulations and with the conditions of your license.

The inspector reviewed selected procedures and records, observed various activities, and interviewed various personnel. Based on the results of this inspection, no findings of significance were identified. No response to this letter is required.

In accordance with Title 10 of the Code of Federal Regulations Section 2.390, Public inspections, exemptions, requests for withholding, a copy of this letter, its enclosure, and your response (if any) will be available electronically for public inspection in the NRC Public Document Room or from the NRCs document system (Agencywide Documents Access and Management System (ADAMS)). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). If you have any questions concerning this inspection, please contact Craig Bassett at (301) 466-4495 or by electronic mail at Craig.Bassett@nrc.gov.

Sincerely,

/RA/

Anthony J. Mendiola, Chief

Research and Test Reactors Oversight Branch

Division of Policy and Rulemaking

Office of Nuclear Reactor Regulation

Docket No. 50-156 License No. R-74

Enclosure:

As stated

cc: See next page

University of Wisconsin

Docket No. 50-156

cc:

Mayor of Madison City Hall 210 Martin Luther King Jr. Boulevard Room 403 Madison, Wisconsin 53703

Chairman, Public Service Commission of Wisconsin 610 North Whitney Way Madison, WI 53707-7854

Paul Schmidt, Manager Radiation Protection Section Division of Public Health Wisconsin Dept of Health Services P.O. Box 2659 Madison, WI 53701-2659

Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611

Jason Timm, Assistant Director

& Radiation Safety Officer University of Madison - Wisconsin Department Environmental Health & Safety Environmental Protection and Safety Bldg.

30 E. Campus Mall Madison, WI 53715