IR 05000156/2011201

From kanterella
Jump to navigation Jump to search
IR 05000156-11-201 on April 25-27, 2011 at the University of Wisconsin
ML111320204
Person / Time
Site: University of Wisconsin
Issue date: 05/19/2011
From: Johnny Eads
Research and Test Reactors Branch B
To: Agasie R
Univ of Wisconsin - Madison
Morlang, G M, NRR/DPR, 415-4092
References
IR-11-201
Download: ML111320204 (21)


Text

SUBJECT:

UNIVERSITY OF WISCONSIN - NRC ROUTINE INSPECTION REPORT NO. 50-156/2011-201

Dear Mr. Agasie:

On April 25 - 27, 2011, the U.S. Nuclear Regulatory Commission (NRC, the Commission)

completed an inspection at your University of Wisconsin Nuclear Reactor Laboratory (Inspection Report No. 50-156/2011-201). The enclosed report documents the inspection results, which were discussed on April 27, 2011, with you and members of your staff.

The inspection examined activities conducted under your license as they relate to safety and compliance with the Commission=s rules and regulations and with the conditions of your license.

The inspector reviewed selected procedures and records, observed activities, and interviewed personnel. Based on the results of this inspection, no findings of significance were identified.

No response to this letter is required.

In accordance with Title 10 of the Code of Federal Regulations, Section 2.390, Public inspections, exemptions, and requests for withholding, a copy of this letter, its enclosure, and your response (if any) will be available electronically for public inspection in the NRC Public Document Room or from the NRCs document system (Agencywide Documents Access and Management System (ADAMS)). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Should you have any questions concerning this inspection, please contact Mike Morlang at (301) 415-4092 or by electronic mail at Gary.Morlang@nrc.gov.

Sincerely,

/RA/

Johnny H. Eads, Jr., Chief Research and Test Reactors Oversight Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-156 License No. R-74 Enclosure: NRC Inspection Report No. 50-156/2011-201 cc w/encls: See next page

University of Wisconsin Docket No. 50-156 cc:

Mayor of Madison City Hall 210 Martin Luther King, Jr. Boulevard, Room 403 Madison, Wisconsin 53703 Chairman, Public Service Commission of Wisconsin 610 North Whitney Way P.O. Box 7854 Madison, WI 53707-7854 Manager Radiation Protection Section Division of Public Health Dept of Health and Family Services P.O. Box 2659 Madison, WI 53701-2659 Victor Goretsky Assistant Director & Radiation Safety Officer Environmental Health & Safety Department 530 Environmental Protection And Safety Bldg 30 N Murray St Madison, WI 53715 Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611

May 19, 2011 Mr.