September 18, 2008
SUBJECT:
NRC INSPECTION REPORT NO. 50-150/2008-201
Dear Dr. Baeslack:
During the period August 18-21, 2008, the U.S. Nuclear Regulatory Commission (NRC)
completed an inspection at your Ohio State University Research Reactor facility. The enclosed report documents the inspection results, which were discussed on August 21, 2008, with Thomas Blue, Director, Nuclear Reactor Laboratory, Andrew Kauffman, Associate Director, Nuclear Reactor Laboratory, and Robert Peterson, Ohio State University Radiation Safety Officer and Director, Radiation Safety Section.
The inspection examined activities conducted under your license as they relate to safety and compliance with the NRC=s rules and regulations and with the conditions of your license. The inspector reviewed selected procedures and records, observed activities, and interviewed personnel. Based on the results of this inspection, no findings of significance were identified.
In accordance with Section 2.390 of Title 10 of the Code of Federal Regulations, APublic Inspections, Exemptions, Requests for Withholding,@ a copy of this letter, its enclosure, and your response (if any) will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records component of NRC=s Agencywide Document Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).
Should you have any questions concerning this inspection, please contact Craig Bassett at (404)
358-6515.
Sincerely,
/RA/
Johnny H. Eads, Branch Chief Research and Test Reactors Branch B Division of Policy and Rulemaking Office of Nuclear Reactor Regulation
Docket No. 50-150 License No. R-075
Enclosure: NRC Inspection Report No. 50-150/2008-201 cc w/enclosure: Please see next page
Ohio State University Docket No. 50-150 cc:
Ohio Department of Health ATTN: Radiological Health Program Director P.O. Box 118 Columbus, OH 43216
Ohio Environmental Protection Agency Division of Planning Environmental Assessment Section P.O. Box 1049 Columbus, OH 43216
Mr. Andrew Kauffman Associate Director Nuclear Reactor Laboratory Ohio State University 1298 Kinnear Rd.
Columbus, OH 43210
Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611
September 18, 2008
Dr. William